Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹4.2 LAccepted-AOC 2ND FLOOR A I ESTATE MOHAN NAGAR GAZIABAD 2023R10524 | L1 | Accepted-AOC L1 | |
| 2 | L2₹4.4 L+₹27,931 (6.70%)Rejected-Finance | L2 | Rejected-Finance L2 |
Tender Value
₹4.2 L
EMD Value
₹8,335
Closing Date
17 Dec 2024, 5:00 pmClosed
PRAMESH Kumar
ED - Hisar
Pdg. Solar Power Plants for Various Rest House under Electric Circle, Karnal(Electric Division Hisar) (Pdg. 500 LPD Solar Water Heating System in CM Suite in PWD Rest House at Tosham in Distt. Bhiwani).
2024_HRY_416555_1
20245AF881A0 CF74 43F1 BCA7 F92A93C2B0EA666BAR
Open Tender
Electrical Works
Works
45 days
Tosham
2 documents required · 2 mandatory
₹500
₹8,335
Yes
11 Jan 2025
10 Dec 2024
18 Dec 2024
10 Dec 2024
17 Dec 2024
10 Dec 2024
Amount
[23.22.5.8]MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 5.8. Supply and erection of miniature circuit Breaker 240/415 V in the existing distribution board including making necessary connections:- 40 amp to 63 amp. MCBs FOUR POLE [Through Rate]
Supply and erection of Temperature meter for solar water heater complete all labour and material required to the complete in all respect up to entire satisfaction of the Engineer-in-Charge of the works. (Excluded GST) Make Green Energy/ Radiant Solar/ Inter Solar
Supply and erection of cold water storage tank of 500 LPD in Four layer with stand in hight 7.8ft. with ( civil work for Cold water Storage Tank and Hot water Pipe line and For Plant )complete with all labour and material required to the complete in all respect up to entire satisfaction of the Engineer-in-Charge of the works) Make :- Syntex / Ganga/ Jindal. Rates are excluding GST .
Supply and erection of pvc sheathed conductor cable copper 6sqmm 4 core 1100 volts grade in pipe of suitable site. Design, Supply, Installation, Testing. Commissioning of power cables/control cables, cable trays, glands with required accessories, etc. from all equipment, pumps to control panel complete as specified and shown in drawings with all labour and material required to the complete in all respect up to entire satisfaction of the Engineer-in-Charge of the works. Make Polycab/ RR kabel/ Grandlay. Rates are excluding GST
Supply and erection of 32mm GI pipe line B class for cold water.with all labour and material required to the complete in all respect up to entire satisfaction of the Engineer-in-Charge of the works.Make:- Jindal / Tata/ Ravindra. Rates are excluding GST.
Supply and erection of 25 mm dia GI Pipe B Class for hot water with 100mm Rockwood insulation. complete all labour and material required to the complete in all respect up to entire satisfaction of the Engineer-in-Charge of the works.Make:- Jindal / Tata/ Ravindra . Rates are excluding GST
Supply and erection of 20mm GI pipe B Class for hot water with 100mm Rockwood insulation. complete all labour and material required to the complete in all respect up to entire satisfaction of the Engineer-in-Charge of the works.Make:- Jindal / Tata/ Ravindra. Rates are excluding GST .
Supply and erection of 15 mm dia GI Pipe B class for hot -water with 100mm Rockwood insulation. complete all labour and material required to the complete in all respect up to entire satisfaction of the Engineer-in-Charge of the works.Make:- Jindal / Tata/ Ravindra. Rates are of exclusive of GST.
Supply and erection of Gate valve in 32mm. complete all labour and material required to the complete in all respect up to entire satisfaction of the Engineer-in-Charge of the works.Make:- Jindal / Tata/ Ravindra. Rates are excluding GST.
Supply and erection of Gate valve in 25mm complete all labour and material required to the complete in all respect up to entire satisfaction of the Engineer-in-Charge of the works. Make:- Jindal / Tata/ Ravindra. Rates are excluding GST.
Supply and erection of 2 Way Angle 15mm Gate valve complete all labour and material required to the complete in all respect up to entire satisfaction of the Engineer-in-Charge of the works.Make:- Jindal / Tata/ Ravindra. Rates are excluding GST.
Supply and erection of Brass Tab for Hot Watercomplete all labour and material required to the complete in all respect up to entire satisfaction of the Engineer-in-Charge of the works. Rates are excluding GST.
Supply and erection of CPVC Pipe (Make: Ashirwad/Prince/Supreme, 25 mm Dia)complete all labour and material required to the complete in all respect up to entire satisfaction of the Engineer-in-Charge of the works. Rates are excluding GST.
Supply and erection of Ball valve in 15mm complete all labour and material required to the complete in all respect up to entire satisfaction of the Engineer-in-Charge of the works. Make:- Jindal / Tata / Ravindra. Rates are excluding GST.
Supply and erection of Electric Heater with thermostat 3 KW complete all labour and material required to the complete in all respect up to entire satisfaction of the Engineer-in-Charge of the works. Make Green Energy/ Radiant / Inter Solar. Rates are excluding GST.
Supply and erection of Booster Motor 1 HP complete all labour and material required to the complete in all respect up to entire satisfaction of the Engineer-in-Charge of the works. Make :- Kirloskar/ Crompton/ CRI . Rates are excluding GST.
Supply / erection / Testing / Commissioning of MCCB Box / Enclosure FP suitable for upto 100 amp MCCB of Havell`s make complete with all accessories complete in all respect upto to the entire satisfaction of the Engineer-in Charge of the work. Rates are excluding GST.
Green Energy Enterprises (BID ID -1181173)
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .