| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹4.7 LAccepted-AOC | L1 | Accepted-AOC Being L1 Bidder | |
| 2 | L2₹4.8 L+₹9,361.59 (1.97%)Rejected-Finance 28 DOCTOR LANE | L2 | Rejected-Finance Being L2 Bidder | |
| 3 | L3₹4.9 L+₹16,642.30 (3.50%)Rejected-Finance NARAYANGARH PANCHAYAT SA MITY P O GARH RADHANAGAR DIST PASCHIM MEDINIPUR WEST BENGAL | HOOGHLY | WEST BENGAL | 712122 | L3 | Rejected-Finance Being L3 Bidder | |
| 4 | L4₹5.0 L+₹21,538.21 (4.54%)Rejected-Finance VILL DAKSHIN SHIBGANJ P O AND P S PATHARPRATIMA DIST SOUTH 24 PARGANAS | SOUTH 24 PARGANAS | WEST BENGAL | L4 | Rejected-Finance Being L4 Bidder | |
| 5 | Rejected-Technical | - | Rejected-Technical Insufficient Documents |
| Sl No | Description | Qty | Unit | R.D.ELECTRICAL ENGINEERING CO L1 | B. ENGINEERING CO. L4 | MAITI ENTERPRISE L3 | K.C. BYSACK AND SONS L2 |
|---|---|---|---|---|---|---|---|
| 1.00 | Supply of LED Tube illuminated sign board fabricated by 40'(L)x3'(H)x10"(W) ACP box supported with 50 x 50 x 6 mm M.S. Angle structure all around with 40mm x40mmx 1.62 mm Al. edge angle for front portion only.The back side of the cover will be fabricated with hinges and arrangement in such a way so that it can be opened for maintenance purpose, including mechanical locking arrangement .The 3 mm ACP facial (Blue colour) should be provided with laser cutting of 5 mm laser cut Acrylic letters out of which 4 mm rising and back portion of the ACP board should be pasted with 2mm thick Clear Acrylic Sheet of same size as ACP facial as per the direction of EIC.The sign board should be illuminated by 18W LED Tube lamps (42 nos.) (Type- MAS LED Tube lamp 18 W 2100 lm) with Tube fittings (Phillips make) to be fixed by hooking arrangement with iron stucture fabricated for fixing purpose. Distribution wiring for power supply to LED fittings to be done by PVC rigid conduit, necessary clamps, cable tie etc. Back side of the of the board should be covered with 20 SWG G.I. sheet to protect rain water. The matter to be displayed will be finalised by authority and to be given later.This fabricated display structure is to be fixed on the top of prefabricated iron structure as per direction of EIC. | 1 | Nos | 1,48,900 ₹1,48,900 | 1,35,600 ₹1,35,600 | 1,30,500 ₹1,30,500 Lowest | 1,40,000 ₹1,40,000 |
| 2.00 | Supply of LED Tube illuminated sign board fabricated by 17.10'(L)x5'(H)x10"(W) ACP box supported with 50 x 50 x 6 mm M.S. Angle structure all around with 40mm x40mmx 1.62 mm Al. edge angle for front portion only.The back side of the cover will be fabricated with hinges and arrangement in such a way so that it can be opened for maintenance purpose, including mechanical locking arrangement .The 3 mm ACP facial (Blue colour) should be provided with laser cutting of 5 mm laser cut Acrylic letters out of which 4 mm rising and back portion of the ACP board should be pasted with 2mm thick Clear Acrylic Sheet of same size as ACP facial as per the direction of EIC.The sign board should be illuminated by 18W LED Tube lamps (24 nos.) (Type- MAS LED Tube lamp 18 W 2100 lm) with Tube fittings (Phillips make) to be fixed by hooking arrangement with iron stucture fabricated for fixing purpose. Distribution wiring for power supply to LED fittings to be done by PVC rigid conduit, necessary clamps, cable tie etc. Back side of the of the board should be covered with 20 SWG G.I. sheet to protect rain water. The matter to be displayed will be finalised by authority and to be given later.This fabricated display structure is to be fixed on the top of prefabricated iron structure as per direction of EIC. | 1 | Nos | 1,18,060 ₹1,18,060 | 1,22,400 ₹1,22,400 | 1,22,640 ₹1,22,640 | 1,10,000 ₹1,10,000 Lowest |
| 3.00 | Fabrication charge of the esixting iron structure incl. hiring of welding machine incl. painting making connection as required for making M.S. structural work in column beam etc. with simple rolled structural members(e.g. joist, angle chanel,section). This plate is to be welded with the precutting roof with fastner and loading unloading from work shop to site for installation of LED Glow Sign Board as per direction of EIC. | 2 | Item | 8,000 ₹16,000 | 8,000 ₹16,000 | 8,000 ₹16,000 | 7,500 ₹15,000 Lowest |
| 4.00S & F PVC rigid conduit (Precision mk) on wall with saddles as per GS. | |||||||
| 4.10 | 20 mm size [ 7(a)/ E- 16 ] | 60 | mtr | 10 ₹600 Lowest | 60 ₹3,600 | 60 ₹3,600 | 51 ₹3,060 |
| 5.00Supplying and Drawing 1.1 KV single core stranded 'FR' PVC insulated & unsheathed single core stranded copper wire of the following sizes in the 19mm/25mm prelaid polythene pipe/PVC rigid conduit as per GS. | |||||||
| 5.10 | 2x(2.5 sqmm)+1x(1.5 sqmm) [ 1(s) / E-9 ] | 60 | mtr | 60 ₹3,600 Lowest | 72 ₹4,320 | 80 ₹4,800 | 70 ₹4,200 |
| 6.00S & F solderless Copper socket by crimping of Copper wires. | |||||||
| 6.10 | a) 1.5 sq mm | 6 | Nos | 4 ₹24 Lowest | 10 ₹60 | 6 ₹36 | 5 ₹30 |
| 6.20 | b) 2.5 sq mm [9(i) / F-5] | 6 | Nos | 7 ₹42 | 12 ₹72 | 7 ₹42 | 6 ₹36 Lowest |
Tender Value
Refer Docs
EMD Value
₹10,000
Closing Date
4 Dec 2024, 2:00 pmClosed
Executive Engineer,Hooghly Electrical Division,PWD
3rd Floor, Purta Bhavan, Sarat sarani, Kodalia Hooghly
SITC of Glow sign Board at Institute of Education P.G for Women, Chandanagar, Hooghly.
2024_WBPWD_770374_1
WBPWD/EE/ HED / NIeT-102 (2nd call) of 2024-25
Open Tender
ELECTRICAL WORKS ORG
Item Rate
10 days
Hooghly
Please refer Tender documents.
4 documents required · 4 mandatory
₹10,000
7 Sept 2026
18 Nov 2024
6 Dec 2024
18 Nov 2024
4 Dec 2024
18 Nov 2024
Amount
Supply of LED Tube illuminated sign board fabricated by 40'(L)x3'(H)x10"(W) ACP box supported with 50 x 50 x 6 mm M.S. Angle structure all around with 40mm x40mmx 1.62 mm Al. edge angle for front portion only.The back side of the cover will be fabricated with hinges and arrangement in such a way so that it can be opened for maintenance purpose, including mechanical locking arrangement .The 3 mm ACP facial (Blue colour) should be provided with laser cutting of 5 mm laser cut Acrylic letters out of which 4 mm rising and back portion of the ACP board should be pasted with 2mm thick Clear Acrylic Sheet of same size as ACP facial as per the direction of EIC.The sign board should be illuminated by 18W LED Tube lamps (42 nos.) (Type- MAS LED Tube lamp 18 W 2100 lm) with Tube fittings (Phillips make) to be fixed by hooking arrangement with iron stucture fabricated for fixing purpose. Distribution wiring for power supply to LED fittings to be done by PVC rigid conduit, necessary clamps, cable tie etc. Back side of the of the board should be covered with 20 SWG G.I. sheet to protect rain water. The matter to be displayed will be finalised by authority and to be given later.This fabricated display structure is to be fixed on the top of prefabricated iron structure as per direction of EIC.
Supply of LED Tube illuminated sign board fabricated by 17.10'(L)x5'(H)x10"(W) ACP box supported with 50 x 50 x 6 mm M.S. Angle structure all around with 40mm x40mmx 1.62 mm Al. edge angle for front portion only.The back side of the cover will be fabricated with hinges and arrangement in such a way so that it can be opened for maintenance purpose, including mechanical locking arrangement .The 3 mm ACP facial (Blue colour) should be provided with laser cutting of 5 mm laser cut Acrylic letters out of which 4 mm rising and back portion of the ACP board should be pasted with 2mm thick Clear Acrylic Sheet of same size as ACP facial as per the direction of EIC.The sign board should be illuminated by 18W LED Tube lamps (24 nos.) (Type- MAS LED Tube lamp 18 W 2100 lm) with Tube fittings (Phillips make) to be fixed by hooking arrangement with iron stucture fabricated for fixing purpose. Distribution wiring for power supply to LED fittings to be done by PVC rigid conduit, necessary clamps, cable tie etc. Back side of the of the board should be covered with 20 SWG G.I. sheet to protect rain water. The matter to be displayed will be finalised by authority and to be given later.This fabricated display structure is to be fixed on the top of prefabricated iron structure as per direction of EIC.
Fabrication charge of the esixting iron structure incl. hiring of welding machine incl. painting making connection as required for making M.S. structural work in column beam etc. with simple rolled structural members(e.g. joist, angle chanel,section). This plate is to be welded with the precutting roof with fastner and loading unloading from work shop to site for installation of LED Glow Sign Board as per direction of EIC.
S & F PVC rigid conduit (Precision mk) on wall with saddles as per GS.
20 mm size [ 7(a)/ E- 16 ]
Supplying and Drawing 1.1 KV single core stranded 'FR' PVC insulated & unsheathed single core stranded copper wire of the following sizes in the 19mm/25mm prelaid polythene pipe/PVC rigid conduit as per GS.
2x(2.5 sqmm)+1x(1.5 sqmm) [ 1(s) / E-9 ]
S & F solderless Copper socket by crimping of Copper wires.
a) 1.5 sq mm
b) 2.5 sq mm [9(i) / F-5]
Supply of 4/3.5/2 Core XLPE Insulated & Sheathed Armoured Aluminium Conductor cables for Working Voltage up to 1100 Volts of following sizes [Make- Gloster/KEI/Havells as approved by E.I.C]
2 Core 6 Sq.mm. (maim switch to pole to sign board)
Laying of one No. cable upto 35 sqmm in underground trench 460 mm wide x 760 mm average depth, with brick protection on the top of the cable with 8 (eight) Nos. bricks per metre, including filling the space between the brick & cable and also the trench with shifted soil, leveling up and restoring surface duly rammed. [ 1(a)/ F- 2 ]
Laying of cable upto 2 core 25 sqmm on wall/surface incl. S & F MS saddles with earthing attachment in 10 SWG GI (Hot Dip) Wire, making holes etc. as necy. mending good damages and painting [ 2(a)/ F- 1 ]
Supplying & fixing medium gauge GI Pipe (ISI-Medium) Protection with necessary fittings as per GS.
40mm dia [11(c)/F-6]
.Supplying and fixing compression type gland complete with brass gland, brass ring & rubber ring for dust & moisture-proof entry of XLPE/PVC armoured cables as below :
2 Core 6 Sq. mm [7(a)/F4 ]
Finishing the end of following XLPE/PVC armoured cables by crimping method incl.supplying and fixing solderless socket (Dowels make), tapes, anticorrosive paste & jointing materials :
2 Core 6 Sq. mm [8(b- ii) /F5]
S/F Stainless Steel water proof looping cable box of size 200x150x100mm having hinged top Cover with rubber gasket lining, railway type mechanical locking anangement, earthing terminal with lug etc. of the following sizes as indicated below, Comprising of one 250 V, 15 A Kit-Kat fuse unit, one NL on porcelain insulator etc. and housing the same on pole above 5ft from ground level by necessary pole clamp .( Sign board and Out door light [NS]
:Supplying and fixing 240V DP with fuse on L&N Sheet steel Main Switches on flat iron frame on wall ( Make - L&T / Siemens /Havells)(D-1/1(a))
Supply & Fixing of 240V 70 W LED Street light luminarie (Crompton Geaves-Cat no. CRP-409-70-57-SL-GL-NSG or equivalent make of Philips/Bajaj//wipro) on ST Pole as per direction of E.I.C
Supply & Fixing of 240V 20 W LED Landscape Lighting luminarie ( make Crompton Cat no. APOR020C or equivalent make of Magik) as per direction of E.I.C
S & F mini pole on roof top by 50 mm dia., 2.5 Mtr. Long GI(M) pipe medium quality (Bansal/Jindal make) incl. making cc (6:2:1) muffing 600x600x750 mm in size with 3 mm thick neatly finished cement plaster incl. S & F 8”x6”x4” C.I. looping cable box incl. This is incl. painting as per GS.
Add GST 18 %
Add Labour Cess 1%
K.C. BYSACK AND SONS (BID ID -5786634)
MAITI ENTERPRISE (BID ID -5804858)
B. ENGINEERING CO. (BID ID -5804796)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .