Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹26.0 LAccepted-AOC | L1 | Accepted-AOC Lowest amount quoted | |
| 2 | L2₹27.6 L+₹1.1 L (4.16%)Rejected-Finance PLOT NO 81 SHANTAJI COLONY JANKI NAGAR JABALPUR MP PIN 482002 | JABALPUR | MADHYA PRADESH | 482002 | L2 | Rejected-Finance Second lowest amount quoted | |
| 3 | L3₹31.3 L+₹4.8 L (18.1%)Rejected-Finance HO SR NO 73 TAPKIR MALA CHOWK TAPKIR NAGAR KALEWADI PIMPRI PUNE 411017 | PUNE | MAHARASHTRA | 411017 | L3 | Rejected-Finance Highest amount quoted |
Tender Value
Refer Docs
EMD Value
₹60,800
Closing Date
29 Mar 2022, 6:00 pmClosed
Shri Dhiraj Kumar, IDSE, EE
Garrison Engineer (East), Near COD Estate, Ranjhi, Jabalpur (MP)-482011
As per BOQ
2022_MES_504272_2
8397/E8
Open Tender
Electrical and Maintenance Works
Item Rate
240 days
Garrison Engineer (East) Jabalpur
D b (i)
7 documents required · 7 mandatory
₹500
Garrison Engineer (East) Jabalpur
₹60,800
Yes
5 May 2022
9 Mar 2022
31 Mar 2022
9 Mar 2022
29 Mar 2022
16 Mar 2022
9 Mar 2022 - 12 Mar 2022
Amount
Dismantling of ACSR/AAC conductor of any size from LT poles or distribution span, GI earthing wire etc complete all as specified & directed.
Dismantling of MS channel or angle sections, insulators any type & sizes, brackets, clamps, nut, bolts, washers, GI earthing wire of any size from LT poles or distribution span etc complete all as specified & directed.
Dismantling of LT Steel Tubular poles and setting aside for re-use within 50 metres complete all as specified and directed. Note : Excavation, RFR, Remova and PCC will be measured and paid separately.
Dismantling and taking down stree light fittings any size and re-fixing again after erecting of Lt pole etc complete all as specified and directed.
Excavation in trenches not exc. 1.5 mtr wide and exc. 1.5 mtr but not exceeding 3.00 mtr in depth, for foundation of poles/Stays etc and and getting out in soft/loose soil complete all as specified and dirtected.
Excavation in trenches for laying of cables ,poles and stay in any type of soil not exceeding 1.5 mtr wide and not exceeding 1.50 mtr deep and getting out complete all as specified and directed.
Returning & filling in, including spreading and leveling, watering and well ramming in layers n.exc. 25 cm all as specified ad dirtected.
Removing excavated materials not exc 50 mtr and depositing where complete all as specified ad dirtected.
Unwashed Sand cushioning to under ground cable provided with a layer of 8 cm deep before laying and 15 cm covering above the top edge of cable after laying complete all as specified. Note : maesurement shall be done after puning down of sand.
M&L for Fly Ash bricks Sub-class 'B' locally available laid flat in trenches over sand cushioning for cable protection complete all as speciffied and directed.
M&L for PCC 1:3:6 type C2 using 40mm graded stone aggregate as in filling & mass concrete complete all as specified and directed.
M&L for PCC 1:3:6 type C1 using 20mm graded stone aggregate as in coping of pole ect including form work & finishing the surfaces even & smooth with out using extra cement complete all as specified and directed.
Material and labour for boring hole under the road/path/pavment/hard standing with the help of trenchless technology using ultra sound technique and necessary machine including HDPE pipe of 150mm dia suitable for 0.4 mpa working pressure not less than one metre below ground level complete all as specified & directe buy Engr-in-charge at site. Note :- The cost of HDPE pipe shall be deemed to be included in quoted rate.
S F cable route indicator/Marker made up of PCC Block in cement mortar 1:3:6 (20 mm graded aggregate) of size 900mm x 300mm x 100mm thick with "DANGER/LT 433 VOLTS CABLE /MES OR DANGER/MES" embossing on canble route Indiator/Marker including painting as per approed colour and buried in ground 45 cms including necessary earth work (as required/ordered at site) complete all as specified and as directed.
S & F for GI Pipe light grade for cable protection passing under road/floor or for fixing to poles all as complete all as specified and directed the following :-
100 mm dia
80 mm dia
50 mm dia
40 mm dia
Supply, Laying & testing and commissioning LT underground cable 1100 volts grade, XLPE insulated and PVC sheathed heavy duty armoured with multi staranded aluminium conductor laid in pipes, trences/ducts, on poles etc of size complete all as specified and directed :-
4 core x 10 sqmm
4 core x 16 sqmm
4 core x 25 sqmm
4 core x 35 sqmm
3.5 core x 50 sqmm
3.5 core x 70 sqmm
3.5 core x 95 sqmm
3.5 core x 120 sqmm
Supply install commissioning and testing floor mounted outdoor cubical type LT Feeder Pillar Box of suitable size fabricated out of 3.15 mm thick CRCA Sheet and angle iron 50 X 50 X 6 mm frame factory made totally enclosed dust and vermin proof both side hinge opening arrangement on front and back with locking arrangement cable entry and exist from bottom with cable glands and gaskets, aluminium bus bar 400 Amps rating fixed on porcelain insulator with internal wiring with suitable size of aluminium strips to be used for incoming and outgoing connection of all switches/MCCB's & Bus-bar. Bus-bar shall be insulated with colour code sleeves/tapes and to be connected with copper lugs, including two coats of synthetic enameled paint on the surface externally & internally over a coat of red oxide primer paint incl. necessary PCC (1 : 3 : 6) type C2 as in foundation all as directed, comprising of the following :-
(a) INCOMING
(i) Thermal magnetic and microprocessor release MCCB 400 Amps, 4 Pole, 36 KA with front operated locking device.
(iv) Indicator Lamp - R - Y - B (Set of three).
(b) OUTGOING
(i) Thermal magnetic MCCB 100 Amps, 4 Pole, 415V, 16 KA. Qty- 02 Ns
(ii) Thermal magnetic MCCB 63 Amps, 4 Pole, 415V, 16 KA. Qty - 06 Nos
(c) digital Timer Switches programmable every 1 min, with backup of 6 yrs, 28 memory locations, current capacity 16A, weekly programme, with 2 changeover, total 28 programme , including 3 phase power contactor 32 Amps complete all as specified and directed, incl. taking down un-serviceable timer switches. Make - Tme switch Indo-asian Code No-TDA44197 & 3 phase contactor 32 A Indo-asian Code No - Z102801 / Legrandat/L&T or eqv. Qty - 01 Nos
Supply install commissioning and testing floor mounted outdoor cubical type LT Feeder Pillar Box of suitable size fabricated out of 3.15 mm thick CRCA Sheet and angle iron 50 X 50 X 6 mm frame factory made totally enclosed dust and vermin proof both side hinge opening arrangement on front and back with locking arrangement cable entry and exist from bottom with cable glands and gaskets, aluminium bus bar 400 Amps rating fixed on porcelain insulator with internal wiring with suitable size of aluminium strips to be used for incoming and outgoing connection of all switches/MCCB's & Bus-bar. Bus-bar shall be insulated with colour code sleeves/tapes and to be connected with copper lugs, including two coats of synthetic enameled paint on the surface externally & internally over a coat of red oxide primer paint incl. necessary PCC (1 : 3 : 6) type C2 as in foundation all as directed, comprising of the following : -
(a) INCOMING
(i) Thermal magnetic MCCB 350 Amps, 4 Pole, 415V, 36 KA Make -Legrand, cat No - 4202 49 /L&T/ Schneider - 01 No
(iv) Indicator Lamp - R - Y - B (Set of three).
(b) OUTGOING
(i) Thermal magnetic MCCB 100 Amps, 4 Pole, 415V, 25 KA Qty - 02 Nos
(ii) Thermal magnetic MCCB 63 Amps, 4 Pole, 415V, 16 KA. Qty - 04 Nos
S & F junction box for street lights of size 300 x 250 x 150 mm made out of CRCA sheet 2 mm thick totally enclosed, dust and vermen proof, rain protected slanted roof top, door pasted with rubber gasket, water tight IP 42 protection single leaf shutter in front having proper locking arrangements and painted with powder coating paint and suitable size of "connectewell" stud terminal (provision for socket bolting) - 05 Nos suitable for 415 voldts, 50 Hz, 3 phase 4 wire internal wiring system including MCB SP 6 Amps - 01 No and mounted on security light pole with suitable bracket nuts, bolts complete all as specified and directed.
Supply and fix Energy saving nww geeration environmental friendly LED street light luminaire with long life versatile pressure die-cast housing with toughened glass and individual LEDs with secondary optics and IP-66 protection with high power LEDs as light source and electronic driver with capacity 60 watts with pre wired and necessary mounting arrangements including provision of 4 sq mm three core copper conductor cable multi stranded from fitting to junction box and including necessary GI pipe medium grade of suitable dia with clamps, nut, bolts, washers for fitting of pvc pipefor steel tubular poles with bracket 1.5 mtr long bend to required shape with suitable with MS clamps made out of flat iron of size 40 x 6 mm - 2 sets, bolts & nuts washers etc for street light fiting complete all as specified and directed.
M & L for earthing complete with galvanized steel earth plate electrode 60cmx60 cmx 6mm thick buried directly in ground vertically (earth pit not less than 2.25m deep below ground level) with top edge of the plate not less than 1.50 mtr deep below normal ground level connecting to and including GI steel strip of size 32 x 6 mm by means of bolts, nuts, check nuts, and washers of galvanized iron or steel including 40 mm dia medium grade pipe for protection of GI strip to the extent of 7.5 mtrs asearthing lead including charcoal dust and salt packed all around the earth plate in the earth pit all as per Electrical plate ZNo 3 of SSR par - I (2009) including PCC foundation/chamber in mix 1:2:4 type B1 with angle iron frame CI frame, CI cover with provision of locking arrangement and 20 mm dia light grade GI pipe from top edge of the earth plate upto MS funnel with wire mesh provided inside the concrete earth pit for watering arrangement complete including excavation and earthwork in any type of strata and testing complete including fill up the earth pit with soil for best result and removal ( for LT Panels). Note :- Earth protection pipe & earthing strip upto and including 7.5 m length is deemed included in unit rate quoted by the contractor.
M&L for earthing complete with galvanized steel earth plate electrode 60cmx60 cmx 6mm thick buried directly in ground vertically (earth pit not less than 2.25m deep below ground level) with top edge of the plate not less than 1.50 mtr deep below normal ground level connecting to and including GI earth wire of size 4.0 mm by means of bolts, nuts, check nuts, and washers of galvanized iron or steel including 15 mm dia medium grade pipe for protection of GI wire to the extent of 7.5 mtrs asearthing lead including charcoal dust and salt packed all around the earth plate in the earth pit all as per Electrical plate ZNo 3 of SSR par - I (2009) including PCC foundation/chamber in mix 1:2:4 type B1 with angle iron frame CI frame, CI cover with provision of locking arrangement and 20 mm dia light grade GI pipe from top edge of the earth plate upto MS funnel with wire mesh provided inside the concrete earth pit for watering arrangement complete including excavation and earthwork in any type of strata and testing complete including fill up the earth pit with soil for best result and removal ( for street light poles). Note :- Earth protection pipe & earthing strip upto and including 7.5 m length is deemed included in unit rate quoted by the contractor.
M&L for earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground and laid down through PVC medium grade conduit complete with fixed to poles or any other indicated situation for loop earthing etc as required 32x6 mm strip aluminium etc completer all as specified and directed by Engr-in-Charge.
Taking down unservisable U/G cable from trenches, wall, floor etc and removing to store for safe custody uopto 25 sqmm Note:- Excavation for taking shall not be paid separatly, the cable shall be deemed to have taken down from the trenches excaveted for laying of cables
Taking down unservisable U/G cable from trenches, wall, floor etc and removing to store for safe custody above 35 opto 120 sqmm. Note:- Excavation for taking shall not be paid separatly, the cable shall be deemed to have taken down from the trenches excaveted for laying of cables
Taking down unservisable LT U/G cable from trenches, wall, floor etc and removing to store for safe custody above 150 to 400 sqmm. Note:- Excavation for taking shall not be paid separatly, the cable shall be deemed to have taken down from the trenches excaveted for laying of cables
Boring of holes under road, pavement, hard standing by trenchless technology using ultra sounding technique and necessary machine including HDPE pipe of 150 mm dia suitable for 0.4 mpa working pressure.
Supply & fix PVC junction box IP 65 Protection of size 0.200 x 0.250 x 0.115 complete with 1 Nos of MCB SP 2.5 Amps & 4 way industrial connector including Clamp made out of MS flat 30X5 mm, connection from junction box to street light fitting with three single core PVC insulated & PVC sheathed wire 2.5 Sqmm copper.
Supply, Installation, test and Commissioning CPRI APPROVED factory fabricated, out door type, LT FEEDER PILLAR BOX of size not less then 1.5 m width X 1.2m heigth X 0.6 m depth,made out of 3.15 mm thick CRCA Sheet with projected Globe roof for rain water protection Dust and Vermin Proof , Double door with both side opening including Neoprene Rubber Gasket, suitable for 440 Volt 3 Phase 4 Wire System, including Danger Plate, Earthing Strip Point and Ventilation Louvers at Rear Side, Bottom detachable Gland Plate complete with suitable size Zinc Chromium Plated Nuts, Bolts and Washers, etc. and embedded with 50X50X6mm Mild Steel Angle Iron Frame and 750 mm above the Normal Ground Level complete with internal connection with suitable size of cable, cable lugs and cable glands PCC Foundation in Cement Concrete 1:3:6 (20 mm Graded Stone Aggregate) and Testing after Installation including complete all as specified and comprising of the following :–
(a) Aluminum bus bar 600 Amps - 01 Set
(b) MCCB 320 A 35 KA, 4 POLE ,thermal magnetic relese, Ics=100% Icu - 2 nos (O/G)
(c) MCCB125 A 25 KA,3 POLE ,thermal magnetic relese, Ics=100% Icu - 6 nos (O/G)
(f) LED TYPE indicator lamp 1 set (set of three for R,Y,B)
Supply, Installation, test and Commissioning CPRI APPROVED factory fabricated, out door type, LT FEEDER PILLAR BOX of size not less then 0 .9 m width X 1.2 m heigth X 0.6 m depth,made out of 3.15 mm thick CRCA Sheet with projected Globe roof for rain water protection Dust and Vermin Proof , Double door with both side opening including Neoprene Rubber Gasket, suitable for 440 Volt 3 Phase 4 Wire System, including Danger Plate, Earthing Strip Point and Ventilation Louvers at Rear Side, Bottom detachable Gland Plate complete with suitable size Zinc Chromium Plated Nuts, Bolts and Washers, etc. and embedded with 50X50X6mm Mild Steel Angle Iron Frame and 750 mm above the Normal Ground Level complete with internal connection with suitable size of cable, cable lugs and cable glands PCC Foundation in Cement Concrete 1:3:6 (20 mm Graded Stone Aggregate) and Testing after Installation including complete all as specified and comprising of the following :–
(a) Aluminum bus bar 400 Amps - 01 Set
(b) MCCB 200 A 35 KA,4 POLE ,thermal magnetic relese, Ics=100% Icu -1 no ( incomming)
(c) MCCB 125 A 25 KA,3 POLE ,thermal magnetic relese, Ics=100% Icu - 2 nos (O/G)
(d) MCCB63 A 25 KA,3 POLE ,thermal magnetic relese, Ics=100% Icu & L&T /Legrand /schneider- 1 nos (O/G)
(g) LED TYPE indicator lamp 1 set (set of three for R,Y,B)
Dismantling of U/S insulator of any size and type complete from its position and removing all as directed by Engr-in-Charge.
Dismantling of U/S stay assembly carefully including stay wire necessary excavation and earth work in any type of soil, demolition of PCC of any type and removing from site all as directed.
LED street light lumanaries NEXUS+ of size 45/48 W pressure die cast aluminium housing with heat resistance toughed glass & IP66 protection Make: CG (Cat Part No LST045CDL) Havells cat no-LHETAXU7PN6W048.
Fabrication and installation of GI pipe bracket made of medium Grade tubing of size 32 mm dia, duly bended by hot forgoing after filling of sand, length 1.20 mtr including pair of MS flat strip clamps 30 mm x 5 mm with GI bolts nuts and washer complete all as specified and directed.
Dismantling unserviceable main switch/ kitkat DBs/ MCB including wooden board from existing position and making good disturbed surfaces of wall to match with existing surfaces.
MCCB DB VERTCLE TYPE made of sheet steel , powder painted with NUTRAL bus bar 200 A, neutral link, IP-43-IK09 protection grade , 415Volts TPN with 4 way Double door.
MCCB TPN 125 Amps , 415Volts, 25KA, 4 POLE
MCCB TPN 100 Amps , 415Volts, 25KA, 4 POLE
MCCB TPN 63 Amps , 415Volts, 25KA, 4 POLE
MCB SP 63 Amps 'C' series, breaking capacity 10 KA of rating
MCB SP 40 Amps 'C' series, breaking capacity 10 KA of rating
MCB SP 6-32 Amps 'C' series, breaking capacity 10 KA of rating
M & L XLPE insulated screened PVC bedded galvanised steel strip or wire armored earthed electric power cable (heavy duty) with aluminum conductor 11 KV (E) grade suitable for earthed system cross sectional area 95 Sq. mm 3 core HT UG cable laid in tranches/through GI pipe/fixed along with pole complete all as specified & directed.
Supply and fix cable jointing kit for 11 KV grade cable for indoor type termination heat shrink type joint complete with jointing material and accessories suitable for 3 Core XLPE armored Aluminum conductor cable of size 95 Sq. mm.
Supply and fix cable jointing kit for 11 KV grade cable for outdoor type termination heat shrink type joint complete with jointing material and accessories suitable for 3 Core XLPE armored aluminum conductor cable of size 95 Sqmm.
Supply & fix cable straight through suitable for XLPE, HT under ground cable, 95 sqmm, 3 core, 11000 volt, heat shrink tpe indoor end termination.
M&L for Switch air break gang operated triple pole mechanically operated mounted on insulator and steel frame out door type suitable for vertical installation single brake provided with locking arrangement, consisting of MS channel ,HT post type insulator ,copper alloy high pressure assembly ,operating rod of 25 mm dia GI pipe medium grade confirming to IS-1818 of 1972 ,suitable for 11000 volt ,200 Amps all as specified.
Brick covering with width equal to length of bricks as mechanical protection to cable with well burnt sub class `B` bricks laid dry and flat complete all as specified and as directed.
Cutting of hardstanding/ Road for laying of pipe line/cable and making good surfaces after laing of pipe line/ cable up tp 30cm in depth complete all as specified and directed.
S&F Cast iron cable route marker of angle length 45 cm with top edge dai of plate 10 cm dai mentioned HT Cable with arrow in respective direction , thickness of plate 5 mm duly enamlled with anti-corrossion paint of approved make all as specified and directed by Engr-in-Charge.
Supply & erect 4 pole structure on 11 meter PCC Pole,anti-climbing device, PCC foundation & cross arms etc for one incoming and three out going as spesified by central electricity regularity commission with prebibed parameter with safty norms all as specified and directed by Engr-in-Charge.
Supply and erect 2 pole structure on 11 meter PCC pole , anti-climbing device, PCC foundation & cross arms etc as spesified by central electricity regularity commission with prebibed parameter with safty norms all as specified and directed by Engr-in-Charge.
Schedule of credit amount of Rs. 52,214.00 to be deducted during AOC
shri krishna traders
Goodluck Enterprises
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .