Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹14.3 LAccepted-AOC 08 PINK ENCLAVE MAHESH NAGAR BALAJI VIHAR GOPALPURA JAIPUR RAJASTHAN 302015 INDIA | JAIPUR | RAJASTHAN | 302015 | L1 | Accepted-AOC Being lowest | |
| 2 | L2₹15.5 L+₹78,332.70 (5.34%)Rejected-Finance PLOT NO 17 GF PRATAP NAGAR NEW DELHI 110064 | WEST | DELHI | 110064 | L2 | Rejected-Finance Being other than lowest | |
| 3 | L3₹17.0 L+₹2.3 L (15.9%)Rejected-Finance H NO 154 VILLAGE SHIKARPUR PO NAJAFGARH NEW DELHI 110043 | WEST | DELHI | 110043 | L3 | Rejected-Finance Being other than lowest | |
| 4 | L4₹19.7 L+₹5.1 L (34.5%)Rejected-Finance | L4 | Rejected-Finance Being other than lowest | |
| 5 | L5₹21.8 L+₹7.1 L (48.6%)Rejected-Finance | L5 | Rejected-Finance Being other than lowest |
Tender Value
Refer Docs
EMD Value
₹40,000
Closing Date
24 Oct 2020, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (East) Delhi Cantt-10
GE (East) Delhi Cantt-10
REPAIR AND CLEANING OF SEWAGE LINES, AND REPAIRS TO DRAINS, BOUNDRY WALLS AT KABUL LINES IN THE AREA OF AGE B/R-II UNDER GE (EAST) DELHI CANTT-10
2020_MES_380980_1
GE/DE-35/2020-21
Open Tender
Civil Works
Item Rate
330 days
GE (East) Delhi Cantt-10
Class E Cat a i
8 documents required · 8 mandatory
₹500
Yes
GE (East) Delhi Cantt-10
₹40,000
Yes
3 Nov 2020
25 Sept 2020
26 Oct 2020
25 Sept 2020
24 Oct 2020
10 Oct 2020
25 Sept 2020 - 2 Oct 2020
60 days
Amount
Demolition of brick work built in cement mortar including all quoins, arches, pillars etc., but excluding ashlar facings, complete all as specified and as directed.
Demolition of cement concrete (unreinforced) of any description and in any position complete all as specified and as directed.
Demolition of cement concrete (reinforced) of any description and in any position complete all as specified and as directed.
Dismentling of RCC jalli of any description and in position and unserviceable jalli removed from site and serviceable jalli stacking at site after cleaning/dusting complete all as specified and as directed.
Taking down cement plaster on brick or stone walls, including racking out joints, hacking for key, scrubbing down with water etc., to receive new plaster, complete all as specified and as directed.
Dismentling of wall and ceiling boards (fibre, pulp, insulation, etc.) or insulation boards/slabs/blankets, any thickness, including cover fillets, complete all as specified and as directed.
Dismantling floor, hearth or wall ceramic tiling including cement mortar bedding (but not backing) and rubbish off the premises, complete all as specified and as directed.
Dismantling wrought iron or mild steel work of any description not other wise provided for, complete all as specified and as directed.
Dismantling of cast iron or reinforced concrete drain pipes, jointed in cement mortar and taking out of trenches/walls, internal dia of pipe 75mm to 100mm, complete all as specified and as directed.
Demolition and breaking up SWR drain pipes ( PVC) set in cement mortar upto 110mm dia, complete all as specified and as directed.
Demolition and breaking up drain pipes (salt-glazed stone ware, AC or reinforced concrete) set in cement mortar 150mm dia, complete all as specified and as directed.
Demolition and breaking up drain pipes (salt-glazed stone ware, AC or reinforced concrete) set in cement mortar 200mm dia, complete all as specified and as directed.
Taking up or down steel tubing and connections 15mm dia including cleaning for refixing and removal off the site, complete all as specified and as directed.
Taking up or down steel tubing and connections 20mm dia including cleaning for refixing and removal off the site, complete all as specified and as directed.
Taking up or down steel tubing and connections 25mm dia including cleaning for refixing and removal off the site, complete all as specified and as directed.
Taking up or down steel tubing and connections 50mm dia including cleaning for refixing and removal off the site, complete all as specified and as directed.
Excavation in trenches not exceeding 1.5mtr wide and not exceeding 1.5mtr deep and getting out complete in any type of soil, complete all as specified and as directed.
Excavation in trenches not exceeding 1.5mtr wide and exceeding 1.5mtr but not exceeding 3.00mtr deep and getting out complete in any type of soil, complete all as specified and as directed.
Returning, filling in, including spreading, leveling watering and well raming in layers not exceeding 25cms thick complete all as specified and as directed.
Removal of surplus soil to a distance not exceeding 50mtrs and depositing where directed at a level not exceeding 1.5 mtr above the starting point, complete all as specified and as directed.
Hard core of gauge not exceeding 63mm stone aggregate, deposited, spread and levelled in layers not exceeding 15 cm thick watering and ramming to a true surface, complete all as specified and directed
Plain cement concrete 1:3:6, Type C-2 using 40mm graded crushed stone aggregate as in foundations, filling and mass concrete, complete all as specified and as directed.
Plain cement concrete 1:2:4 type B-1 as in benching, coping and similar items including weathering, slightly rounded or chamfered angles and throating on top of chajjas, rails, cills etc., complete all as specified and as directed.
Providing precast reinforced cement concrete 1:2:4 type B1 using 20mm graded crushed stone aggregate in louvers and jallies, 35 mm thick (measured solid), including all mouldings but excluding frame (precast frame shall be measured separately) set in cement mortar 1:4, complete all as specified and as directed.
Providing precast reinforced cement concrete 1:2:4 type B1 using 20mm graded crushed stone aggregate 25cm wide and 50mm thick as in benching, coping and similar items including weathering, slightly rounded or chamfered angles and throating on top of chajjas, rails, cills etc., set in cement mortar 1:4, complete all as specified and as directed.
PCC 1:2:4 type B-1 as in benching, coping, roof kerb, mud stops etc., and similar items including weathering, slightly rounded or chamfered angles and throating on top of chajjas, rails, cills etc., complete all as specified and as directed.
Precast cement concrete 1:2:4 type B-1 using 20mm graded crushed stone aggregate, as in manhole cover slabs and the like, set in cement mortar 1:4, complete all as specified and as directed.
Plain cement concrete 1:2:4, Type B-2 using 40mm graded crushed stone aggregate as in surface channels and drains, complete all as specified and as directed.
Brick work with sub class “B” bricks straight or curved on plan exceeding 6mtr mean radius built in cement mortar 1:6 using old size bricks, complete all as specified and as directed.
All as per description of Srl item No.- 29 here-in-before but except bricks, complete all as specified and as directed.
Brick work with sub class “B” bricks straight or curved on plan exceeding 6mtr mean radius built in cement mortar 1:4 using old size bricks, complete all as specified and as directed.
Brick work with sub class “B” bricks straight or curved on plan built to any radius in cement mortar 1:4 using old size bricks in half brick walls, complete all as specified and as directed.
Mild steel TMT bars upto 10mm dia, cut to length, bent to shape required, including cranking, bending, spirally for hopping for columns, hooking ends, and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips quality conforming to Fe-410-S or Fe-410-0, complete all as specified and as directed.
Mild steel framed work as in grills, gratings etc., with ends of bars shouldered and or riveted or forged into spikes, framed guard bars, barred iron doors, ladder, framed balusters, railing, frame work for water tanks and similar work, complete conforming to Fe 290 Gde-E-165 including shop coat of red oxide including preparation of surface before fixing, complete all as specified and as directed.
GI frame work for seamless ceiling comprising of GI perimeter channel 0.55mm thick with two unequal flanges of 20 and 30mm and web of 27mm fixed to surrounding wall using nylon sleeves and screws at 450mm centre to centre/intermediate channel 0.9mm thick having equal flanges of 15mm each and web of 45mm suspended from soffit at approx 900mm centre to centre with GI cleat and steel expansion fasteners with and including ceiling section (not exc 1.2m length) of 0.55mm thickness having kurled web of 50mm and flange of 26mm each with lips of 10.5mm fixed to the intermediate channel at 457mm centre to centre and Hangers 6mm dia GI (upto 1200mm length) adjusting level fixed to roof slabs by means of ceiling cleats made out of GI flat 40 x 3mm size 60mm long and expansion hold fasteners 12.5mm dia, 40mm long, complete all as specified and as directed.
4 mm thick Non asbestos fibre cement building fixed or laid/inserted to timber/GI/Aluminium framework with screws, complete all as specified and as directed.
Pre-polished coloured chequered cement concrete tiles, factory made, Premium quality 300mm x 300mm x 25mm thick, set, jointed in neat cement slurry and pointed flush with grey cement mixed with pigments to match colour of blocks in floors over 15 mm thick screed bed or bedding layer in cementy mortar 1:4, complete all as specified and as directed.
Vibro compacted Precast concrete interlocking paver blocks, factory made,any shape and size conforming to IS- 15658- 2006 of 60mm thick, M-35 Grade set, jointed in neat cement slurry and pointed flush with grey cement mixed with pigments to match colour of blocks in floors laid over 30mm thick sand cushioning, complete all as specified and as directed.
75 mm thick plain cement concrete 1:3:6 type C-2, using 40mm graded crushed stone aggregate as in plinth protection finished even and fair, complete all as specified and as directed.
75 mm thick plain cement concrete 1:4:8 type D-2, using 40mm graded crushed stone aggregate as in sub base finished even and fair, complete all as specified and as directed.
Joint less Non skid ceramic coloured floor tiles of size 400mm x 400mm, 7-8mm thick, as in floors set and jointed in neat cement slurry and pointed in white cement with pigments to match over and including the provision of 15 mm thick bedding layer in cement mortar 1:4, complete all as specified and as directed.
Joint less Non skid ceramic coloured floor tiles of size 300mm x 300mm, 7-8mm thick, as in floors set and jointed in neat cement slurry and pointed in white cement with pigments to match over and including the provision of 15 mm thick bedding layer in cement mortar 1:4, complete all as specified and as directed.
Glazed ceramic coloured tiles 300mm x 200mm, 6-7mm thick in vertical surfaces, set and jointed in neat cement slurry and pointed in coloured cement to match tiles over 10mm thick backing coat in cement mortar 1:4, complete all as specified and as directed.
Rendering 15mm thick on fair faces of brick work or concrete surfaces in cement mortar 1:4 finished even and smooth without using extra cement, complete all as specified and as directed.
Rendering 15mm thick on fair faces of brick work or concrete surfaces in cement mortar 1:6 finished even and smooth without using extra cement, complete all as specified and as directed.
Preparing newly plastered surfaces of walls and applying two coats of cement base paint, complete all as specified and as directed.
Preparation of new steel or iron surfaces of any description, over 10cm in width or girth, not otherwise described and applying two coats of synthetic enamel paint ordinary tint over a coat of red oxide zinc chrome primer, complete all as specified and as directed.
Cutting chases for concealed water tubing girth exceeding 10cm but not exceeding 20cm girth and making good in cement mortar 1:3 in brick walls, complete all as specified and as directed.
15mm bore GI tubing (medium grade) with all fittings and fixed complete to walls and ceiling or laid in floors/roofs including taking down old tubing, complete all as specified and as directed.
All as per description of Srl item No.- 49 here-in-before but fixing only, complete all as specified and as directed.
20mm bore GI tubing (medium grade) with all fittings and fixed complete to walls and ceiling or laid in floors/roofs including taking down old tubing, complete all as specified and as directed.
All as per description of Srl item No.- 51 here-in-before but fixing only, complete all as specified and as directed.
25mm bore GI tubing (medium grade) with all fittings and fixed complete to walls and ceiling or laid in floors/roofs including taking down old tubing, complete all as specified and as directed.
50mm bore GI tubing (medium grade) with all fittings and fixed complete to walls and ceiling or laid in floors/roofs including taking down old tubing, complete all as specified and as directed.
Sand cast iron soil waste and vent pipes 100mm dia, in any length, with cement joints, laid in trenches/floors, fixed to walls with CI/MS holder bat clamps and conforming to IS-1729, complete all as specified and as directed.
Sand cast iron soil waste and vent pipes 75mm dia, in any length, with cement joints, laid in trenches/floors, fixed to walls with CI/MS holder bat clamps and conforming to IS-1729, complete all as specified and as directed.
CI bend for 100mm bore any radius, diminishing pieces or tapers (larger bore measured), fixed to walls, complete all as specified and as directed.
CI bend for 75mm bore any radius, diminishing pieces or tapers (larger bore measured), fixed to walls, complete all as specified and as directed.
CI bend for 50mm bore any radius, diminishing pieces or tapers (larger bore measured), fixed to walls, complete all as specified and as directed.
100mm bore cast iron branch pieces single (equal or unequal) ordinary or inverted, complete all as specified and as directed.
75mm bore cast iron branch pieces single (equal or unequal) ordinary or inverted, complete all as specified and as directed.
50mm bore cast iron branch pieces single (equal or unequal) ordinary or inverted, complete all as specified and as directed.
100mm bore cast iron sanitay connection 'P' or 'S' branch, with branch 370 to 450mm long excluding joint, complete all as specified and as directed.
CI floor trap, with grating including jointing to 75mm bore waste pipe fixed in cement concrete 1:2:4, type B-1, complete all as specified and as directed.
CI vent cowl of 100mm bore, complete all as specified and as directed.
CI vent cowl of 75mm bore, complete all as specified and as directed.
CI vent cowl of 50mm bore, complete all as specified and as directed.
CI oval access door covers for 100mm dia cast iron pipe fittings, fixed in any position, complete all as specified and as directed.
CI oval access door covers for 75mm dia cast iron pipe fittings, fixed in any position, complete all as specified and as directed.
100mm bore stack clamps out of 50mm by 5mm flat iron and 16mm dia round iron stays, including securing ends of stays to wall or roof, fixed in repairs, complete all as specified and as directed.
75mm bore stack clamps out of 50mm by 5mm flat iron and 16mm dia round iron stays, including securing ends of stays to wall or roof, fixed in repairs, complete all as specified and as directed.
PVC 110mm bore (SWR) pipes single socketed, in any length with rubber ring joints, flaid in trenches or in floors, complete all as specified and as directed.
PVC 75mm bore (SWR) pipes single socketed, in any length with rubber ring joints, flaid in trenches or in floors, complete all as specified and as directed.
PVC 50mm bore (SWR) pipes single socketed, in any length with rubber ring joints, flaid in trenches or in floors, complete all as specified and as directed.
PVC (SWR) bend of 110mm bore any radius, complete all as specified and as directed.
PVC (SWR) bend of 75mm bore any radius, complete all as specified and as directed.
PVC (SWR) bend of 50mm bore any radius, complete all as specified and as directed.
Cement concrete type D-2 1:4:8 (using 40 mm graded crushed stone aggregate) in bed to drain pipe 150 mm dia including packing under and haunching against the sides of pipe after they are laid and tested complete all as specified and directed.
Cement concrete type D-2 1:4:8 (using 40 mm graded crushed stone aggregate) in bed to drain pipe 200 mm dia including packing under and haunching against the sides of pipe after they are laid and tested complete all as specified and directed.
SGSW pipe 150 mm dia including jointing with cmenet mortar, complete all as specified and directed.
SGSW pipe 200 mm dia including jointing with cmenet mortar, complete all as specified and directed.
Factory made steel fibre reinforced(SFRC) man hole covers with frame including necessary hold fast/lugs for embedding (medium duty) 560mm dia or redctangular of equivalent area conforming to IS-12592, complete all as specified and as directed.
Factory made steel fibre reinforced(SFRC) man hole covers only (medium duty) 560mm dia or redctangular of equivalent area conforming to IS-12592, complete all as specified and as directed.
Vitreous china wash down water closet pan (pedestal pattern) excluding flushing cistern and flush pipe, including fixing of water closet complete with plastic water closet seat black/white closed pattern witrh flat bottom and cover and mild steel chromium plated or aluminised hinging device, fixed in repairs, complete all as specified and as directed.
Viterous China water closet squatting pan, 'Orrisa' pattern, size 580 x440 mm white, with integral foot rests (excluding flushing cistern and flush pipe) complete including connectoin to trap, and to flushing pipe, anti syphonage pipe etc. including trap set in and including concrete and making good to floors, fixed in repairs, complete all as specified and as directed.
PVC 10 Ltrs valve less, syphonic action type, flushing cistern, low level, white, with inlet, ball valve, float and handle including brackets complete with flush pipe etc. ISI approved, fixed in repairs, complete all as specified and as directed.
Vitreous china wash hand basin, white flat back size 550mm x 400mm including waste pipe, brackets and 32mm dia bore CP coupling, fixed in repairs, complete all as specified and as directed.
Pillar tap, cast copper alloy, fancy type with capstan heads, chromium plated, screwed down high pressure with or without lettered "Hot" or "cold" with long screwed shanks and fly nuts, screwed for iron pipe of bore 15mm, fixed in repairs complete all as specified and as directed.
PVC connections 450mm long, 15 mm size with brass chromium plated nuts at ends, fixed in repair, complete all as specified and as directed.
PVC connections 600mm long, 15 mm size with brass chromium plated nuts at ends, fixed in repair, complete all as specified and as directed.
Racking out cement/lead joints of CI pipes 100mm/75mm dia and filling with lead joints/neat cement mortar to stop leakage of joints, complete all as specified and as directed by Engineer-in-Charge.
Salt glazed stone ware gully trap,square or round mouthed,150 x 150 mm size,shape as required,including dismantling and taking out of old GT and jointing with old connection and pipes, fixed in repairs, complete all as specified and as directed by Engineer-in-Charge.
Cleaning and removing all scale and dirt, etc, from tanks and from mouth of circulating pipes etc., of capacity not exceeding 500 Ltrs complete including writing date of cleaning with approved quality synthetic enamel paint, complete all as specified and as directed.
Cleaning and removing all scale and dirt, etc, from tanks and from mouth of circulating pipes etc., of capacity exc 500 Ltrs and not exceeding 1000 ltrs complete including writing date of cleaning with approved quality synthetic enamel paint, complete all as specified and as directed.
Mechanically operated 25 tonne truck mounted desludger with 12000Ltr capacity tanker having water fitted high pressure jet machine for cleaning and desludging of sewage line, shall be used by the contractor as per scheduled programme in writing and completion of each job to the entire satisfaction of Engineer-in-Charge as instructed. ( NOTE : a) Per day means 8 working hours in a day excluding stand by period due to any sort of reason. b) In case contractor fails to deploy the machine as per scheduled programme a recovery of Rs 2000/- per day shall be deducted from his payment.)
Cleaning and maintenance of rain water pipes, open drains, sewage system including WHB bottle traps, Nahani traps, water closet, soil / wastage pipe running on external walls of bldgs, junction holes of any description, sewage line of any sizes including manholes upto the final drop outlet into the septic tank of external sewage system in running / flowing order without blockage of any description in any situations including making Julla arrangement to work in high rise buildings externally upto 8 stories height and clearing of blockages by mechanical means or manually and disposing waste materials out side defence land strictly as per Hon'ble Supreme Court directions, complete all as specified and as directed by the Engineer-in-Charge.
NOTE: a) The above task shall be caried out by deploying 06 safaiwalas on all days including Sundays and Holidays between 0900 Hrs to 1700Hrs, Two numbers for each pocket of (i) Kabul Lines -02 Nos. (ii) FAFA- 02 Nos. (iii) OTM Accn Area- 02 Nos. b) One mechanical pump diesel/petrol for dewatering sludge water, safety belt, ladder, gloves gasmask, bucket to remove sludge, mechnical device required to reach work at difficult locations shall be made available all time at site to ensure heigene and sanitation during work. c) Daily attendance shall be maintained in the Attendance Register by the JE concerned and a recovery for absent period shall be made @ Rs 500/- per person per day. All relevent record shall be maintained by the contractor and to be submitted before making any payment duly signed by Engineer-in-Charge & JE concerned. d) Work will be carried out in Multistoreyed Building upto 08 storeys and Jula arrangement including all safety measures are to be provided by the contractor under his own arrangement, rate of which are deemed to be included in the rates quoted against above mentioned item.
Breaking up drain pipes (SGSW/AC/RCC) of any size by puncturing, cleaning of blockage by roding and making good of broken/punctured portion of pipes by changing of drain pipes (SGSW/AC/RCC) and sealing the joints with cement mortar 1:3 or PCC 1:2:4 type B-1 for no leakage including necessary earth work, excavation in any type of soil upto any depth, returning filling and removal of surplus soil to a distance not exc 50 mtr from the starting point, complete all as specified and as directed by Engineer-in-Charge.
CI fittings such as Tees, bends, branch pieces, floor traps etc., upto 100mm dia (waste water/rain water/soil waste pipe) where ever required to stop leakage including testing of leakage upto eight storied building, fixed in repairs, complete all as specified and as directed. Note :- The necessary steel scaffolding upto eight storeyed whereever required to complete the job shall be provided by the contractor with all safety equipments and the rate for scaffolding & safty equipments shall be deemed to be included in the quotted rates by the contractor and nothing extra shall be paid on this account.
PVC/UPVC fittings such as Tees, bends, branch pieces, floor traps etc., upto 100mm dia (waste water/rain water/soil waste pipe) where ever required to stop leakage including testing of leakage upto eight storied building, fixed in repairs, complete all as specified and as directed. Note :- The necessary steel scaffolding upto eight storeyed whereever required to complete the job shall be provided by the contractor with all safety equipments and the rate for scaffolding & safty equipments shall be deemed to be included in the quotted rates by the contractor and nothing extra shall be paid on this account.
Dewatering of soak wells, sump wells including bailing out water from it and removing sludge and blockages from inlet and outlet of sewer lines including taking out the excavated sludge and carting away the same to a distance far away from residential/office area and cover the same with fresh earth and recommissioning the same including and disposing waste materials out side defence land strictly as per Hon'ble Supreme Court directions, complete all as specified and as directed.
Cleaning of 25 users septic tank including bailing out water, from it and removing sludge and blockages from inlet and outlet of sewer lines including taking out the excavated sludge and carting away the same to a distance far away from residential/office area and cover the same with fresh earth and recommissioning the septic tank including and disposing waste materials out side defence land strictly as per Hon'ble Supreme Court directions, complete all as specified and as directed by Engineer-in-Charge.
Cleaning of 50 users septic tank including bailing out water, from it and removing sludge and blockages from inlet and outlet of sewer lines including taking out the excavated sludge and carting away the same to a distance far away from residential/office area and cover the same with fresh earth and recommissioning the septic tank including and disposing waste materials out side defence land strictly as per Hon'ble Supreme Court directions, complete all as specified and as directed by Engineer-in-Charge.
Cleaning of 100 users septic tank including bailing out water, from it and removing sludge and blockages from inlet and outlet of sewer lines including taking out the excavated sludge and carting away the same to a distance far away from residential/office area and cover the same with fresh earth and recommissioning the septic tank including and disposing waste materials out side defence land strictly as per Hon'ble Supreme Court directions, complete all as specified and as directed by Engineer-in-Charge.
NOTE:- For minimum fair wages, EPF and payment to labour employed, refer Sch A Note No-14,15 and Special Condition No 5 & 21.2 of this tender. Contractor must produce all the relevent record such as payment made to labour, EPF etc at the time of payment of RARs/Final bill. No payment will be released to contrator without producing the proper record.
NOTE:- Irrespective of whatever specified elsewhere in tender documents, all the debris/waste materials produced out of above mentioned work shall be removed out of Cantonement land and disposed off at locations notified by the Delhi Cantonment Board for disposal of waste building materials within NCR area, without any extra cost to Department under own arrangement of contractors. The rates quoted by the contractors against the items catered here-in-above in the BOQ are inclusive of said provision.
M/s Durga Traders
M/s Shubh Enterprises
P.H. construction
GAUTAM ELECTRIC WORKS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .