Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹37.6 LAccepted-AOC | L1 | Accepted-AOC L1 | |
| 2 | L2₹38.9 L+₹1.3 L (3.34%)Rejected-AOC | L2 | Rejected-AOC L2 |
Tender Value
₹41.8 L
EMD Value
₹84,000
Closing Date
14 Feb 2023, 5:00 pmClosed
XEN Electrical Division No. 1 Shimla
The Executive Engineer Electrical Division No-1 HPPWD Shimla-9
CO Hospital and MCH Block Building at Kather tehsil Distt. Solan HP SH SITC of Fire Alarm P.A System therein
2023_PWD_68030_1
Electrical Division-I dated 08.02.2023
Open Tender
Electrical Works
Item Rate
365 days
SHIMLA
Please refer Tender documents.
7 documents required · 7 mandatory
₹2,000
E.E.Electrical Division No-I Shimla-9
₹84,000
5 Jul 2023
6 Feb 2023
15 Feb 2023
6 Feb 2023
14 Feb 2023
6 Feb 2023
Amount
Supply,Installation,Testing and Commissioning of 3 loop addressable fire alarm control panel, expandable up to 32 loops. Controller shall be 7 inch color touch screen display with stylus (320*240 pixels), inbuilt networking port(both RS485 & Ethernet),TCP/IPport,Serial port for printer,two supervisory inputs,two position key switch and USB port for programming.The Panel shall handle 4096 detection points,10,000history events,menu driven user interface with smart search.The events shall be displayed indifferent colors-red for alarm events & yellow for trouble etc.for easy identification.The Panel shall beVDS/EN54/UL approved. Makes:Bosch/Honeywell(Gamewell)/Siemens (Fire finder)
Supply, Installation, Testing and Commissioning Active Repeater Panel. Controller shall be 5.7 inch color touch screen display with stylus(320*240 pixels), inbuilt networking port(both RS485&Ethernet),Serial port for printer,two supervisory inputs,two position key switch and USB port for programming. The Repeater Panel shall allow users to acknowledge, reset,silence, program, view hisory events...etc (All functions similar to main panel)The user interface of the repeater panel shall be same as the Main Controller with menu driven user interface with smart search. The events shall be displayed in different colorsred for alarm events & yellow for trouble etc. for easy identification. The Panel shall be VDS/EN 54/UL approved. Makes:Bosch/Honeywell(Gamewell)/Siemens (Fire finder)
Supply, Installation, Testing and Commissioning of addressable multisensor detector with a combination of Optical and Thermal including mounting base, auto addressing feauture as required.Detetctor should have 2 inbuilt isolators as per NFPA 72 style 7 wiring requirements (one for incoming and one for outgoing line) for maintaining operational availability of all elements in the loop in the event of a short circuit and to meet style 7 requirements. High resistance to electromagnetic effects in accordance with EFSG agreement EFSG/F/97/005 .Detector should monitor Electromagnetic interference and report to the panel - current and average values. EMC safety for detector shall be 50 V/m. Shall be EN54/ VDs/UL certification) Makes:Bosch/Honeywell(Gamewell)/Siemens (Fire finder)
Supply, Installation, Testing and Commissioning of Intelligent Addressable Double Action Indoor Application Manual Pull Stations / Manual Call Points suitable for wall/column mounting. MCP shall have red coloured housing with molded, raised-letter operating instructions of contrast colour. The MCP shall latch mechanically upon operation and shall remain so until manually reset with its key by an authorized operator. The MCP shall have operating temperature range from 0°C to 50°C and humidity tolerance range up to 93% RH, Non-Condensing. The MCP Shall have VDS/EN 54/UL approved. The MCP Shall have inbuilt isolator. Makes:Bosch/Honeywell(Gamewell)/Siemens (Fire finder)
Supply, Installation, Testing and Commissioning of Intelligent Addressable Potential-free, Form-C, SPDT contact based control module to trigger 3rd party utilities like AHU shut-off, Pressurization fan activation, Special notification activation etc. The contact shall be rated for 2A@24Vdc (Resistive) & 1A@24Vdc (Inductive). The control module shall have operating temperature range from 0°C to 49°C and a humidity tolerance of up to 93% RH, Non-Condensing. Module Shall be VDS/EN 54/UL approved. Makes:Bosch/Honeywell(Gamewell)/Siemens (Fire finder)
SITC of Glow Type EXIT Sign Board photo luminescent of size 300 mm x 250 mm x 1.5 mm rigid sheet signage containing Zink Sulphate as bare chemical class – 1 material PSPA fixed on 3 mm acrylic sheet on both side showing marking (running man, Arrow and Exit) and hanged with the ceiling with chain and fastener including cost of labour & material required to complete the job in all respect up to the entire satisfaction of Engineer-in-Charge of work Make:HEINRICH/ OMEX/ COOPER/Agni
Supply and erection of 1.5sqmm PVC unsheathed copper conductor cable two core 1100 volts grade in pipe of suitable size excluding cost and erection of pipe .Make Polycab/Havells/ KEI
Supply, installation, testing and commissioning of 2 core multistrand 1.5 sq mm annealed copper conductor speaker cable in existing pipe/ channel I/C connection etc. Make: Finolex/Polycab/havells/KEI
Supply and erection of PVC pipe 25mm dia ISI marked (Medium) recessed in wall / ceiling etc. including the cost of PVC bends, inspection boxes, iron hooks and cement concrete etc. complete in all respect upto the entire satisfaction of Engineer-in-charge of work. Make: BEC/AKG/Kalinga/Diplast
Supply, installation, testing and commissioning of 22 U Standard rack to place all equipment. Make: Valrack/Comrack/HCL
SITC of EN-54 Certified IP based EVAC PA controller capable of adding 12 zones in the system and expandable upto 150 zones with 14x 4 Audio matrix with full DSP functionality. 8 audio inputs, 4 audio outputs, 4 channel output matrix. Shall support amplifier redundany, 12 speaker line outputs. 8000 fault, warning and event conditions log. Built in message manager for 100 emergency/business calls up to 85 minutes. 18 control inputs and 19 control outputs. Impedance measurement and Pilot Tone supervision for speaker line monitoring. The controllers shall be able to exchange audio signals over the network without the need of a running PC/server, software dependent solutions shall not be accepted. Multiple controllers can be networked over IP using Dante audio up to 16 digital audio input signals and 16 digital audio output channels with low latency.Audio flows Up to 16 ✕ 16 simultaneous audio [email protected] response (ref. 1 kHz) 20 Hz to 20 kHz (-0.5 dB), Signal-to-noise ratio (A-weighted): Line in to line out: 106 dB typical, THD+N < 0.05%, Sample rate 48 kHz, DSP processing resolution 24-bit linear A/D and D/A conversion, 48-bit processing. Makes:Bosch/Honeywell(Gamewell)/Siemens (Fire finder)
SITC of EN-60065 certified booster amplifier Output 480 W,70/100V loudspeaker output voltages,Line input 2x,Frequency responce 60Hz to 18Khz (+1/-3db at -10db ref. rated output). Audio input level limiter, RMS output power limiter, high temperature, DC, short circuit, mains undervoltage protection, DC supply undervoltage protection, inrush current limiter, ground fault. Makes:Bosch/Honeywell(Gamewell)/Siemens (Fire finder)
SITC of 6W ceiling mount/ wall Mount speaker with excellent speech & music reproduction Max Power: 9W,Rated Power: 6Watts, Power Tapping: 6/3/1.5W- Effective frequency range(-10 dB) : 200 Hz to 15KHz,SPL at rated power (1Khz at 1 m) 96 dBOpening Angle 1 KHz / 4 KHz (-6 dB): 150/70./Makes:Bosch/Honeywell(Gamewell)/Siemens (Fire finder)
TARUN FIRE SYSTEM
stage.html
html • 0.04 MB
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .