Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹12.0 LAccepted-AOC 221 3 SALT LAKE SECTOR II KOLKATA 700091 | KOLKATA | KOLKATA | WEST BENGAL | 700091 | L1 | Accepted-AOC Being L1 Bidder | |
| 2 | L2₹16.3 L+₹20,262 (1.26%)Rejected-AOC NICHUPALLY BOLPUR BIRBHUM PIN 731204 | BOLPUR | BIRBHUM | WEST BENGAL | 731204 | L2 | Rejected-AOC Being L2 Bidder | |
| 3 | L3₹16.6 L+₹48,400 (3.01%)Rejected-Finance BHATTACHARIYA PARA SURI BIRBHUM | SURI | BIRBHUM | WEST BENGAL | L3 | Rejected-Finance Being L3 Bidder | |
| 4 | L4₹16.7 L+₹60,355 (3.75%)Rejected-Finance INDIRA HATIA BIRBHUM | BIRBHUM | BIRBHUM | WEST BENGAL | L4 | Rejected-Finance Being L4 Bidder |
Tender Value
Refer Docs
EMD Value
₹32,500
Closing Date
5 Feb 2021, 5:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Executive Engineer,PWD,Birbhum ELectrical Division
Laldighipara, P.O. SuriDist. Birbhum. Pin. 731101 Near SuriSadar Hospital
Repair and renovation of internal Electrical Installation works at Bolpur Sub Divisional Hospital of Birbhum Distric......renovation of E.I at SNCU,pump panel, UPS service line, additional and allied E.I works.
2021_WBPWD_318139_1
BIRED/28/e-NIQ / MSCL (1st call) of 2020-2021
Open Tender
ELECTRICAL WORKS ORG
Item Rate
14 days
Bolpur Birbhum
Please refer Tender documents.
8 documents required · 8 mandatory
₹32,500
Office of The Exe Eng,Birbhum Elec Divn,PWD
6 Oct 2021
21 Jan 2021
8 Feb 2021
21 Jan 2021
5 Feb 2021
25 Jan 2021
25 Jan 2021
120 days
Amount
Supply & Fixing of 20W LED spot light on existing G.I pipe with necessary arrangement as required.[Model No-BVP132(20W)] Philips. [NS]
Supplying & fixing medium gauge GI Pipe ( ISI-Medium)Protection with necessary fittings and jointing metarials asrequired.
32 mm dia [ 11(b) / F-6 ]
Supplying and fixing 415V, TPN SFU with sheetsteel enclosure on angle iron frame on wall as per GS.( Make -L&T ).
Supplying and fixing 415V, TPN on load front operated Changeover switch with Sheet Steel enclosure on angle iron frame on wall with nutsbolts etc as per GS [ Make L& T ].
Supplying and fixing sheet steel (16SWG) cable end box on TPN SFU enclosure as per GS attachment 63/125A
Supplying and fixing 415V 5 H.P D.O.L starter (L&T MAKE) on wall with angle iron frame, nut, bolt etc as required. [NS]
S&F AC machine timer for one no. machine febricated with double door 8Way SPNDB as per L&T Cat no-LTSDO8N) i) 240 V, 32A DP MCB of breaking capacity 10KA & ''C'' Charecteristic (L&T)-1no ii) 240 V, 32A SP MCB of breaking capacity 10KA & ''C'' Charecteristic (L&T)-1no iii) 22A TP power contactor with 220 coil voltage (L&T, Cat no-MNX22-2P, CS90238)-1 No. iv) Digital timer switch (L&T, cat no-Crono 67DDTO)-1no [N/S]
Supplying & Fixing sheet metal inspection box (16 SWG) of the following sizes(in mm ) flushed in wall as per GS 240 x 200 x 65
Supply & Fixing bakelite / perspex top cover on existing Inspection board by Brass screws 240 x 200 x 65
Supply of 3.5 Core 95 sq mm XLPE Insulated & Sheathed Armoured Aluminium Conductor cables for Working Voltage up to 1100 Volts of following sizes [ Make-Polycab/KEI / Gloster]
Laying of cable as below, on existing Cable Tray and binding with suitable size GI wire as per GS, From 70sqmm to 150sqmm
Supplying and fixing compression type gland and finishing those for following XLPE armoured cable ( 3.5)Core as per GS. 3 Core 95 Sq. mm
Supplying and Drawing 1.1 KV single core stranded 'FR' PVC insulated & unsheathed single core stranded copper wire of the following sizes in the prelaid polythene pipe as per GS.
2x(2.5 sqmm)+1x(1.5 sqmm) [ 1(s) / E-9 ]
4x(16 sqmm)+2x(6 sqmm) [ NS ]
4x(25 sqmm)+2x(10 sqmm) [ NS ]
Cutting Channel of required size on masonry wall by Electric operated cutting machine incl. supplying & fixing of heavy gauge Polythene pipe of following diameter as per GS. 13 mm dia 3 mm thick
Supplying and fixing double door Vertical TPN MCB Distribution board for MCCB incomer with IP-42/43 protection, on angle iron frame on wall as per GS( Make - Legrand )
8 Way ( Up to 160 A ) [15 / D- 11 ]
4 Way ( Up to 160 A ) [15 / D- 11 ]
Supplying and fixing 415 V Four Pole MCCB of Breaking capacity 25kA/35kA in existing Vertical DBs including necessary connection as per GS [ Make - Legrand ]. 125A FP
Supplying and fixing 240/415 V MCB of Breaking capacity 10kA & C characteristics on din rail of existing DBs and necessary connectionas per GS [ Make -Legrand ] 63A TP
Supplying and fixing double door Horizontal TPN MCB Distribution board with IP-42/43 protection, concealed in wall as per GS.( Make - Legrand ) 6 Way
Supplying and fixing 240/415 V MCB Isolator on din rail of existing DBs and necessary connection as perGS [Make-Legrand ] 63A FP
Supplying and fixing 240/415 V MCB of Breaking capacity 10kA & C characteristics on din rail of existing DBs and necessary connectionas per GS [ Make -Legrand ] 6-32 SP
Finishing of the PVC insulated wire ends by socketting with pin/ring type copper sockets and insulated tapes etc., includingsupplying sockets, tapes.
1.5sqmm- [NS]
2.5sqmm- [9(i)/F-5]
4 sqmm [9(ii)/F-5]
6 sqmm [9(iii)/F-5]
10 sqmm [9(iv)/F-5]
16 sqmm [9(iv)/F-5]
25 sqmm [9(iv)/F-5]
Supply & Fixing of perforated GI cable tray with perforation not more than 17.5% suspended from ceiling incl. S&F GI connector, 6mm dia MS suspender, bolts & nuts, steel fastener etc. as required of the following size. Incl. Al painting of MS support With 25x25x3mm angle iron support 300x50x1.25mm (18SWG) [ 34(a) / D-14 ]
Supply & Fixing of 450mm ceiling Fan down rod.
Dismantling the old iron clad Main switch fron existing industrial panel and fixing the front handle (L&T) Main switch to the existing panel with necessary arrangement like angle iron frame, nut, bolt etc as required. (250A M.S-1No, 125A M.S-2 No, 63A M.S-1No)
Terms and conditions:- 1. Rates should be quoted in words as well as in figures Inclusive of all taxes, duties and delivery charges. 2. Manufacturer’s Test Certificate should be produced During delivery/ Commissioning. 3. All materials, equipments and accessories for the Genset must be as per the latest relevant I.S.S. 4. All equipments must be warranted for a period of 12(Twelve) months from the date of commissioning. 5. Price variation clause will not be accepted. 6. Terms of payment:- as per PWD norms. . 7. Conditional offer specially in deviation to the above clauses is liable to cancellation.
NOTE: 1.The Agency must procure the materials from the manufacture /OEM or from their authorised sales channel so that the standard warranty/support of the manufacture /OEM becomes applicable to the products to be delivered and installed by them 2.Documents that authenticates such procurement from the manufacture /OEM or from their authorised sales channel and standard warranty/support should be sent from the e-mail of the manufacture /OEM /authorised sales channel to the e mail of Engineer -in charge and hard copy of it to be submitted during execution of work/submission of Bill. 3. If any refurbished material is supplied and installed , Panel action will be will be takena as per existing rules. 4. 12% GST and 1% labour wellfare cess will be deduct from the bill.
NARAYAN CHANDRA DAS
BISWANATH CHATTERJEE
B M ELECTRIC
stage.html
html • 0.05 MB
technical_602017.pdf
PDF • 0.89 MB
techsummary_602017.pdf
PDF • 0.06 MB
finance_602017.pdf
PDF • 0.06 MB
BOQ Comparative Chart
xlsx • 0.01 MB
finsummary_602017.pdf
PDF • 0.09 MB
20211006165740.pdf
PDF • 0.10 MB
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .