Loading…
Loading…
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance | Admitted-Finance |
| 2 | Paramount Building Solution Admitted-Finance | Admitted-Finance |
| 3 | Not Admitted-Finance 24 SHANTI BHAWAN DHARI ROAD BELTARI PITHORAGARH UTTARAKHAND 262520 | PITHORAGARH | UTTARAKHAND | 262520 | Not Admitted-Finance Not qualified for AOC |
Tender Value
₹18.4 L
EMD Value
₹36,873
Closing Date
15 Jul 2020, 3:00 pmClosed
SE, UWD, GGSIPU
SE, UWD GGSIPU Sector 16C, Dwarka
Operation and maintenance of water supply system and Annual Maintenance of fire fighting System in the University Campus
2020_GGSIP_192448_1
05/SE/UWD/Elect/2020-21
Open Tender
Electrical Works
Works
365 days
SE, UWD GGSIPU Sector 16C
Please refer Tender documents.
10 documents required · 10 mandatory
₹0
₹36,873
21 Aug 2020
7 Jul 2020
15 Jul 2020
7 Jul 2020
15 Jul 2020
7 Jul 2020
Amount
Operation and maintenance (Routine and Preventive) of water supply system as per the Inventory attached including Submersible Pumps, Booster pumps, monoblock centrifugal pumps, water softening plant, filters all related accessories, panels, starter panels, cables, pipes, valves, instruments etc complete including supply of all required consumables item like resin, salt, etc for smooth running of water supply system as per the direction of Engineer-in-charge. The item includes all manpower minimum 1 operator round the clock as required. and one helper in general shift. only on week days. (Inventory as per AnnexureII to be operated,but scope of without preventive/routine maintenance job)
Providing consumables like salt, resin, for running of softner and miscellenous material like Gland dori, dhoti, grease etc for the preventive maintenance of Pump installation as required.
Dosing of suitable chlorine for disinfection as required for drinking water including material, manpower, transport etc all complete as per direction of engineer-in-charge.
Repair of horizontal/vertical type centrifugal pump set connected with upto 5 HP TEFC induction motor upto 3500 RPM suitable for 400/440 volts 3 phase 50 Hz AC Supply repairs includes the complete overhauling , replacement of defective parts i/c mechanical seal , rewinding ,the motor and replacement of Bushes/Bearing etc,as required i/c dismantle material like copper scrape and iron scrape as credit item on buy back basis.Make:- GRUNDFOS.
Rewinding of motor i/c replacement of mechanical seal with suitable size of copper conductor wire, complete with processing of lamination, varnishing, baking etc including testing & commissioning ,taking away the dismental material as credit on by back basis as required. GRUNDFOS - Hydropneumatic / Booster Pump Motor 10H.P
Rewinding of motor i/c replacement of mechanical seal with suitable size of copper conductor wire, complete with processing of lamination, varnishing, baking etc including testing & commissioning ,taking away the dismental material as credit on by back basis as required. KIRLOSKER- Sump pump motor 5 H.P.
Repairing of monoblock 1H.P submersible pumps set (Sump pump) suitable for 400/440 Volts 3 Phase 50Hz Ac supply repairs includes the complete overhauling, replacement of defective parts i/c mechanical seal, rewinding the mump motor etc as required i/c dismantle material like copper scrape and iron scrape as credit item on buy back basis Make:- GRUNDFOS.
Replacement of 50 mm multi port valve including dismantling and fixing new multi port valve in MGF tank and taking away old valve. Make:- Medas.
Carrying out the checking and periodic preventive maintenance of fire fighting pumps, Automation, star Delta starters, Electrical Panel, Pressure Gauges, Valves and all associated accessories, as per the Inventory attached of Pump House No. I & II. Also to carryout the system operational drill once in three months and check the functioning of the complete fire fighting installation in the University Campus. Identifying the defects if any anywhere in the system and report to Engineer-in-Charge for his directions etc as required.
Providing , fixing, testing and commissioning of industrial type pressure guage of 100 mm dia. for inspection of the pressure of flow of water complete as required.
Painting ( one or more coats) on pipes and fittings with synthetic enamel paint of approved brand and manufacture and required colour on old work: a)75/80mm diameter pipes
Painting ( one or more coats) on pipes and fittings with synthetic enamel paint of approved brand and manufacture and required colour on old work: b) 100 mm diameter pipes
Painting ( one or more coats) on pipes and fittings with synthetic enamel paint of approved brand and manufacture and required colour on old work: c) 150 mm diameter pipes
Painting ( one or more coats) on pipes and fittings with synthetic enamel paint of approved brand and manufacture and required colour on old work: d) 200mm diameter pipes
Painting ( one or more coats) on pipes and fittings with synthetic enamel paint of approved brand and manufacture and required colour on old work: e) 300mm diameter pipes
Painting ( one or more coats) on pipes and fittings with synthetic enamel paint of approved brand and manufacture and required colour on old work: f) 50mm diameter pipes
Painting ( one or more coats) on pipes and fittings with synthetic enamel paint of approved brand and manufacture and required colour on old work: g) 20mm diameter pipes
Painting ( one or more coats) on pipes and fittings with synthetic enamel paint of approved brand and manufacture and required colour on old work: h) Hose box
To carryout the "B" Check of 92 HP Diesel Engine of Kirloskar make, Type: 6 R 1080, coupled with Fire Pump testing etc, as required including i) Oil Filter - 01 No.ii) Fuel Filter Set - 01 Set iii) Air Filter Set -01 Set iv) Coolant - 03 Ltrs. v) Replacement of burnt out lube oil with new lube oil (Lube Oil shall be supplied by Deptt. free of cost)
Supply Installation Testing & Commissioning of following sizes butterfly valve of PN 1.6 rating with bronze/gunmetal seat duly as per ISI 13095 complete with rubber gasket, nut bolt washers etc complete as required (Make: Kartar./Zoloto/Adaco. a)100 mm dia
Supply Installation Testing & Commissioning of following sizes butterfly valve of PN 1.6 rating with bronze/gunmetal seat duly as per ISI 13095 complete with rubber gasket, nut bolt washers etc complete as required (Make: Kartar./Zoloto/Adaco. b)80 mm dia
Supply Installation Testing & Commissioning of following sizes butterfly valve of PN 1.6 rating with bronze/gunmetal seat duly as per ISI 13095 complete with rubber gasket, nut bolt washers etc complete as required (Make: Kartar./Zoloto/Adaco. c)150mm dia
Repairs of 100 H.P 3 phase Main fire pump motor set of Kirloskar make model D8M 100/36 including replacing the front & Rear Bearings, Mechanical seal, sleeve, seal plate etc. tasting commissioning, as required.
Supplying and fixing first-aid Hose Reel with MS construction spray painted in post office red, conforming to IS 884 complete with the following as required. 20 mm nominal internal dia water hose thermoplastic (Textile reinforced) type -2 as per IS: 12585 20 mm nominal internal dia gun metal globe valve & nozzle. Drum and brackets for fixing the equipmets on wall. Connections from riser with 25 mm dia stop gun metal valve & M.S. Pipe and socket. 30 Mtrs
Providing & fixing flow switch in following sizes M.S. pipe including connection etc as required. 150mm Dia
Providing, fixing, testing & commissioning of 15mm dia quartzoid bulb type sprinklers of rating 68 degree centigrade with required accessories : Pendent Sprinkler
Paramount Building Solution
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .