| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹14.3 CrAccepted-AOC | ₹14.3 Cr Quoted ₹14.8 Cr | L1 | Accepted-AOC L1 |
| 2 | L2₹16.7 CrRejected-AOC | ₹16.7 Cr | L2 | Rejected-AOC L2 |
| 3 | L3₹17.7 CrRejected-AOC 87 MARIUM MAHAL SADAR BAZAR BARRACKPORE KOLKATA 700120 WB | 24 PARAGANAS NORTH | WEST BENGAL | 700120 | ₹17.7 Cr | L3 | Rejected-AOC L3 |
Tender Value
₹13.6 Cr
EMD Value
₹23.6 L
Closing Date
15 Jul 2020, 2:00 pmClosed
The Exe., Engg., PWD, WD-I, Daman.
The Multi Office Complex, 2nd Floor, Near Moti Daman Market, Moti Daman.
Construction of Road, Landscaping, Parking and other allied works for Govt. Engineering College, Varkund, Nani Daman. (3rd Call)
2020_DAMAN_909_1
Tender Notice No.33/01/2020-21
Open Tender
Civil Works
330 days
Daman District
Please refer Tender documents.
2 documents required · 2 mandatory
₹1,500
The Exe., Engg., PWD, WD-I, Daman.
₹23.6 L
The Exe., Engg., PWD, WD-I, Daman.
26 Nov 2020
1 Jul 2020
15 Jul 2020
1 Jul 2020
15 Jul 2020
1 Jul 2020
10 Jul 2020
Amount
Civil work
A-CIVIL WORK Excavation for foundation upto1.50 MT depth including sorting out and stacking of useful materials and disposing the excavated stuff up to all lead and lift ( A ) loose or Soft Soil as directed by the Engineering- Charge
Excavation for foundation for depth from 1.50 MT to 3.0 m depth including sorting out and stracking of usefulmaterials and disposing the excaveted stuff upto all lead and lift (B) Dense or hard soil as directed by the Engineering- Charge
Excavation for foundation for depth from 3.00 MT to 5.0 m depth including sorting out and stacking of usefulmaterials and disposing the excaveted stuff upto all lead and lift (B) Dense or hard soil as directed by the Engineering- Charge
Filling available excavated Earth (Excluding Rock ) in trenchs, plinth, sides of foundation etc. in layers not exceeding 20 cm in depth consolidating each deposited layer by ramming and watering as directed by the Engineering- Charge
Construction of granular sub-base by providing close graded material mixing in a mechanical mix plant at OMC, carriage of mixed Material to work site, spreading in uniform layers with motor grader on prepared surface and compacting with vibratory power roller to achieve the desired density, compare as per clause 401 of MORTH Specifications as directed by the Engineering- Charge
Supplying and spreading of murrum / binding material including all lead and lift as directed by the Engineering- Charge
Rolling and consolidation of soling including filling in depression which occur during the process, with power roler 8 tonne to 12 tonne. as directed by the Engineering- Charge
Providing and Laying interlocking/non interlocking Cement concrete paver blocks 80mm thick of M40 grade of approved make and shape including leveling the base with 50mm thick sand bedding, laying the paver blocks in pattern as directed by the EIC, filling the joints with sand including watering, rolling and compacting with appropriate tools and plants, all conveyance including loading, unloading of blocks etc.complete in all respect. Brands: VYARA, “basant betton” as approved by EIC, as directed by the Engineering- Charge
Providing and laying cement concrete 1:4:8 (1- Cement : 4- coarse sand : 8- stone aggregates 40 mm nominal size) and curing complete excluding cost of formwork in (A) Foundation and Plinth complete as directed by Engineer-in-charge including all material and abour complete. as directed by the Engineering- Charge
Providing and laying cement concrete 1:3:6 (1-Cement : 3- coarse sand : 6- stone aggregates 40 mm nominal size) and curing complete excluding cost of formwork in (A) Foundation and Plinth as directed by the Engineering- Charge
Uncoursed Rubble Masonry with hard stone of approved quality in foundations and plinth in Cement Mortar 1:6 (1-cement : 6-coarse sand including levelling up etc. complete as directed by the Engineering- Charge
Brick work using common burnt clay building bricks having crushing strength not less than 35 kg./Sq.Cm. in super structure in Cement Mortar 1:6 (1- Cement : 6 -fine sand)(B) Conventional for GF & FF
Providing and fixing masonary work with AAC (autoclaved aerated concrete) blocks 0.23 mt wide, with minimum compressive strength of 3 N/mm2, density of around 575 kg/cu mt and fixing them with ultratech fixobond jointing mortar etc complete as per the instruction given by engineer-in-charge for ground and first floor as directed by the Engineering- Charge
Providing and fixing TMT FE - 500D (Ductile) steel bars reinforcement for rcc work confirming to IS 1789-2008 and of tested quality of TATA, SAIL, JINDAL, make including bending, binding and placing in position as per the drawing and instruction of Engineer-in-charge etc completeup for ground floor and first floor as directed by the Engineering- Charge
Providing and laying River-washed finish Kota 25 mm thk stone slab/ flooring in required design and patterns, in linear as well as curvilinear portions all complete as per the architectural drawings with grooves over 25 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with cement slurry admixed with pigment of matching shade including wastage,rubbing, cutting, curing and polishing etc all complete as specified and as directed by the Engineering- Charge as directed by the Engineering- Charge
Providing and laying River-washed finish Kaddaph 25 mm thk stone slab/ flooring in required design and patterns, in linear as well as curvilinear portions all complete as per the architectural drawings with grooves over 25 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with cement slurry admixed with pigment of matching shade including wastage,rubbing, cutting, curing and polishing etc all complete as specified and as directed by the Engineering- Charge
Providing and laying Polished kota stone PLANTER SIL flooring with groove below over 20mm (Avg) thick base of cement mortar 1:6 (1 cement : 6 coarse sand ) of laid over and jointed with grey cement slurry including rubbing and polishing complete. [A] 20 to 25 mm thick as directed by the Engineering- Charge
20 mm th. sand faced cement plaster on walls upto height 10 rmts above ground level consisting of 12 mm th. backing coat of C.M. 1:3 (1 cement: 3 sand) and 8 mm th. finishing coat of C.M. 1:1 (1 cement: 1 sand) etc. complete.as directed by engineer in charge with all labours and materials complete. as directed by the Engineering- Charge
providing 15mm thick cement plaster in single coat on fair side of brick / concrete wall for interior plastering up to floor two level finished even and smooth in C M 1:4 ( 1 cement 4 coarse sand) including finishing with a flouting coat of neat cement slurry with Niru finish complete. For ground floor and first floor as directed by the Engineering- Charge
providing 10mm the cement plaster on ceiling in single coat on fair side of brick / concrete wall for interior plastering up to floor two level finished even and smooth in C M 1:4 ( 1 cement 4 coarse sand) including finishing with a floating coat of neat cement slurry with Niru finish complete. For ceiling ground floor and first floor as directed by the Engineering- Charge
Wall painting (two coats) with plastic emulsion paint of approved brand and manufacture on undecorated wall surface to give an even shade including throughly brushing the surface free from mortar droppings and other foreign matter and sand papered smooth. as directed by the Engineering- Charge
Removing and scraping of old deteriorated plaster of any thickness fromm wall / R.C.C member including stacking of serviceable material and disposal of unserviceable from site of work with all lead and lift as directed by the Engineering- Charge
Dismentling doors, windows, ventilators etc. (wood or steel) shutters including chowkhats architraves, holdfasts and other attachment etc. complete and stacking them within all lead and lift.(i) Not exceeding 3 Sq.M. in area. as directed by the Engineering- Charge
Providing and fixing colour anodised aluminum window, partially openable /Sliding as directed by the Engineering- Charge/ partially fixed glass window using main frame jindal #8462, 0.526 kg/m, # 8464, 0.764 kg/m,shutter frame of jindal 8463, 0.760 kg/m and clip, section jindal 8461, 0.286 kg/m with silicon packing & rubber gasket with 5 mm thick toughened glass in shutter and 5mm clear glass (modi float, saint gobain, asahi or eq.) and Imax top hung hinges and AISI 316 GRADE stainless steel handles of KICH or eq., locking arrangement complete with fixing etc complete as per the drawing supplied by the architect as directed by the Engineering- Charge
Providing 125 mm thick M-300 controlled Cement concrete road using Tremix vaccum dewatering system with mixing Conplast P-211 ( water reduction concrete admixture ) @ 100 ML per bag of cement with mixing of Recon 3S fibers ( reliance product ) at 125 gms per bags of cement with providing and fixing & removing of " C " channel having size 75 x 75 mm as per required level slope and thickness of concrete and leveling and finishing the concrete using surface vibrator , power floater and trowel light brooming on as directed. including making expansion joint of size 20 x 200 mm & filling the expansion joint using Colpar 200 as per manufactures specitions by cutting of joint using concrete cutter machine etc. complete as directed by the Engineering- Charge
Providing and fixing pre-cast concrete kerb stone of gray cement based concrete block 30cm length,30cm height and 15cm thick of M250 grade concret as per approved design and including excavation for fixing in proper line and level,filling the joint with C:M 1:3 (1cement:3finesand) etc complete. as directed by the Engineering- Charge
Manufacture, supply and delivery of RCC PRECAST DRAIN of M40 grade drain with size 600 x 450 x 100mm as per specification and drawing attached with the tender documents for sizes as mentioned. The rates includes all taxes loading, carting, unloading, stacking etc complete. as directed by the Engineering- Charge
Finishing wall with weather proof exterior emulsion paint on wall surface (two coats) to give an required shape even shade after thoroughly brushing the surface to remove all dirt, and remains of loose powdered materials.etc complete of Asian ultima, ICI weathershield max, Nerolac mica marble make. as directed by the Engineering- Charge
Providing and laying cement concrete 1:3:6 (1- Cement : 3- Coarse sand : 6- crushed stone aggregates 20 mm nominal size) and curing complete including cost of formwork in (A) Wall Caps / Coping as directed by the Engineering- Charge
Providing and laying controlled cement concrete M-250 and curing complete including the cost of form work but excluding the cost of reinforcement for reinforced concrete work in : (a) Foundations, footings Bases of columns and the like and Mass concrete. as directed by the Engineering- Charge
Providing and laying controlled cement concrete M-250 and curing complete including the cost of form work but excluding the cost of reinforcement for reinforced concrete work in : (c) Beams, girders and cantilever up to floor For plinth beamsas directed by the Engineering- Charge
Providing and laying controlled cement concrete M-250 and curing complete including the cost of form work but excluding the cost of reinforcement for reinforced concrete work in : Columns, pillars, posts and struts up to floor two level. Up to Ground level,Ground Floor & First floor as directed by the Engineering- Charge
Providing and laying controlled cement concrete M-250 and curing complete including the cost of form work but excluding the cost of reinforcement for reinforced concrete work in : (c) Beams, girders and cantilever For ground floor and first floor as directed by the Engineering- Charge
Providing and laying controlled cement concrete M-250 and curing complete including the cost of form work but excluding the cost of reinforcement for reinforced concrete work in : slab of ground floor as directed by the Engineering- Charge
Providing and laying controlled cement concrete M-250 for curing complete including the cost of form work and excluding the cost of reinforcement for reinforced concrete work in Walls from top of foundation level up to floor two level. For Ground Floor and first floor as directed by the Engineering- Charge
Earthwork for embankment including breaking clods, dressing with all lead and lift and including watering rolling and consolidation of subgrade in layers at O.M.C. to required dry density including filling the depression which occur during the process using power roller 8T to 10T. With all lead & lift as directed by the Engineering- Charge
Providing and laying 250m thick (in two equal layers) of wet mix macadam using machine crushed chips as per required gradation mixing with required optimum water converting the mix to site and camber with mechanically paver, consolidation with vibratory road roller including all material etc complete as directed by engineer in charge.
Providing and Laying compacted 50mm thick dense graded bituminious macadam (DBM) Grade-2 in single layer using 100-120 TPH batch type HMP producing an average output of 75 tonnes per hour, tack coat at the rate of 10.0Kg / 10 m2 in each using crushed aggregates of specified grading premixed with bituminious content @ 4.5% (VG-30) by weight of total mix and filler, transporting the hot mix to work site laying with a paver finisher with sensor control with minimum road width or as directed by Engineer in charge to the required grade, level and alignment, rolling with smooth wheeled vibratory and tandem rollers to achieve the desired compaction as per MORT&H specification etc complete in all respects. The agency shall have to get the mix design done from approved laboratory and submit to the Engineer in charge for Approval. If the asphalt (bituminious) content is more than above, the agency shall have to bear the cost of additional asphalt. The payment shall be done on the permissible field density achieved on the ite instead of density derieved in the mix design. (Assume density = 2.40 gms / cm3) as directed by the Engineering- Charge
Providing and Laying 40mm thick Bituminious Concrete with 100-120 TPH batch type hot mix plant producing an average output of 75 tonnes per hour capacity using tack coat at the rate of 2.5 Kg / 10 m2 in each using crushed aggregates of specified grading, premixed with bituminous binder @ 5.4% of mix and filler, transporting the hot mix to work site, laying with a paver finisher with sensor control to the required grade, level and alignment, rolling with smooth wheeled, vibratory and tandem rollers to achieve the desired compaction as per MORTH specification clause no 509 complete in all respects as directed by the Engineering- Charge
Applying bituminous paint VG-30 @ 6 kg / 10 sq.mt incl heating the bitumen and sparying by tanker etc completed . as directed by the Engineering- Charge
P & L 24" x 24" vitrified 8 mm thick tile flooring over 20 mm (average) base of cement mortar 1:6 ( 1 cement: 6 coarse sand) on new surface or fixing on existing flooring by adhesive material including dismentaling of existing flooring and jointed with color cement slurry including finised with flush pointing & cleaning the surface etc. complete for antiskit (make Johnson, Kajaria, Asian, RAK, NITCO). as directed by the Engineering- Charge
Providing and laying Riverwash/natural finish Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineering- Charge : Flamed finish granite stone slab Jet Black, Cherry Red, Elite Brown, Cat Eye or equivalent.
Providing and fixing 10x10x7.50 cm Granite kADDAPA stone block hand cut and chisel dressed on top, for paving in floors, drains etc. laid over 20mm thick base mortar 1:4 (1cement:4 coarse sand) with joints 10mm wide filled with same mortar including ruled pointing etc. complete as per direction of engineer-in charge.
Providing and fixing of 25 mm thick EPDM flooring for Childrens play area in multi colour with 6mm thick EPDM granule top layer, 19 mm thick SBR rubber layer, applied with fast curing polyurathine binder including wastage and complete as per EIC (Brands Ecoflex, Koochieplay, Ebaco)
Providing and carrying out Washed stone grit plaster on exterior walls height upto 12 metre above ground level, in two layers, under layer 12 mm cement plaster 1:4 (1cement : 4 coarse sand ), furrowing the under layer with scratching tool,applying cement slurry on the under layer @ 2 Kg of cement per square metre, top layer 15 mm cement plaster 1:1/ 2:2 (1 cement: 1/2 coarse sand : 2 stone chipping 10 mm nominal size), in panels with groove all around as per approved pattern, including scrubbing and washing the top layer with brushes and water to expose the stone chippings ,complete as per specification and direction of Engineer
Forming groove of uniform size from 12x12 mm and upto 25x15 mm in the top layer of washed stone grit plastered surface as per approved pattern, including providing and fixing aluminum channels of appropriate size and thickness (not less than 2 mm), nailed to the under layer with rust proof screws and nails and finishing the groove complete as per specifications and direction of the Engineerin-Charge.
Providing laying (to level or slopes) and jointing reinforced concrete Light duty non-pressure pipes I.S. class NP2 of the following internal diameter with collars and butt ends prepared for collar joints including testing of joints complete.(D) 300mm
Providing and fixing wet Baleshwar/Teakwood sand blasted stone cladding of minimum 25 mm thickness on wall surface over 15 mm thick cement plaster 1:3 (1 cement : 3 sand) with all grooves and pattern for any size and fixing the stone with required chemical of weber, hi-bond platinum make as approved and filling the grooves with cement grout and as per all the specifications and design given by the Architect and directed by the Engineer-in-charge
Providing & laying weep hole in Aburtments, and returns by using A.C. pipe of 100mm including laying in proper grede and jointing the completed as per detailed specification.
Providing and filling sand/gravel behind abutments and between returns in layers as directed
CONSTRUCTION OF 8 LAYER ACRYLIC CUSHION SYSTEM WITH ASPHALT BASE SURFACE: Construction of base surface for outdoor sports courts with WBM and asphalt surface consists of : • Excavation of existing earth and making of sub-grade maintaining a proper standard slope and/or as per standard requirement duly compacted with the road roller. • Carry out anti termite and weedicide on the total area as per the std procedure. • Providing and laying of WBM 6” thk densely compacted with a proper interlocked stones, avoiding voids among the stones etc. • Providing and laying of 30-35mm compacted thick Hot Mix asphalt BM course after proper cleaning. • Providing and laying of 15to20mm compacted thick Hot Mix A.C. course • Providing and laying of Seal Coat with stone dust/sand. RETAINING WALL: Providing and making of Retaining Masonry wall 9” thk & 10” high) upto the asphalt top surfaced level or above duly plastered on the visible portion. DRAIN: Providing & Making of Drain – 6”-8” wide inside the court on the lower edge of the court, maintaining a proper slope towards outlet mouth to make a smooth running of the water. as per all the specifications and design given by the Architect and directed by the Engineer-in-charge
SYNTHETIC ACRYLIC PROCUSHION STANDARD SYSTEM: Supply and application of ITF approved “SPORT-MASTER” USA all weather synthetic cushioned surface system consisting of: Cleaning the base surface, application of adhesion promoter (Incase of Concrete Surface), one layer of Level Master (Resurfacer), two layers of Cushion Master-II and one layer of Cushion Master-I followed by one acrylic textured base coat colour master and two acrylic non-textured top coat finish colour including game line marking all as per International standard and quality. as per all the specifications and design given by the Architect and directed by the Engineer-in-charge
Providing and fixing in position partly fixed and partly openable door with single / double shutter and made with standard extruded anodised hollow section of size 100 x 38 mm frame of approved shade and filled with indian wood and shutter made of 35 mm thick water proof flush door of greenlam, everest, kitply or equivalent make with 1 mm thick laminate of royal touche, greenlam, euro or equivalent make of any shade on both the sides with necessary hardware of high grade anticorrosive AISI 316 matt stainless steel of kich or equivalent make like handle (200 mm), dead lock, door stop, stopper, hinges with necessary adhesive (fevicol) with all labour etc complete as per the as per all the specifications and design given by the Architect and directed by the Engineer-in-charge
Providing anticorrosive treatment to reinforcement with fusion bonded epoxy coating FBEC for substructure and superstructure except liners and ht strength as per all the specifications and design given by the Architect and directed by the Engineer-in-charge
Providing & fixing Louvers of anodized aluminium sections of jindal make made from horizontal and vertical members of sizes 75 x 25 x 1.52 mm (Wt. 0.91 kg/rmt) and 100 x 25 x 1.56mm (0.95 kg/rmt) fixed at 75 mm c/c horizontal distance including cutting at 45 degree where necessary and fixing to wall and erection on site without damaging existing stone or plaster wall surface etc. complete as per design given by the Architect
Providing and laying of Hot applied Thermoplastic compound 2.5 mm thick including Reflectorising Glass Beads @ 250 gms per sqm area, thickness of 2.5 mm is exclusive of surface applied glass beads as per IRC : 35 & finished surface to be level, uniform and free from streaks and holes. (As per Government letter No.SOR 102003/94/S-1/ Dated.20-7-2004)
B-PLANTS AND SHRUBS A. Landscaping work AREA DRESSING AND LAND LEVELLING: Scraping and removing of top soil 450 mm th and debris from exsiting ground and levelling of ground for garden development as per proposed levels etc. complete as directed by engineer-in-charge. ( lead 3 KM )
SHRUBBERY/HEDGE PLANTATION (6 plants/M2, 1' height) :Supply & plantation of shrubbery plants (To be planted in garden soil over already dressed area ) development of bed, cultivation soil mixture and plantation of shrubbery (as per plantation plan provided). Pesticides application to be done as per requirement, application of soil additive @ 5kg per M2 etc. Complete as directed by engineer-in-charge.
TREE PLANTATION (Terminalia 5' ft Height) : Providing and Supply & plantation of trees as per specified plantation plan. This will also include excavation of pits (90cm x 90cm x 90cm) ,mixing of soil additive @ 10kg per pit and existing soil, pesticides application and staking of 1 eucalyptus with 2 coat of military green colour, tied from 2 – 3 places as required. Tree plantation should be carried out neatly accurately as per drawing and etc. Complete as directed by engineer-in-charge.
SHRUBBERY PLANTATION (10 plants/M2, 1'height) :Providing and Supply & plantation of shrubbery plants (To be planted in garden soil over already dressed area ) development of bed, cultivation soil mixture and plantation of shrubbery (as per plantation plan provided). Pesticides application as per requirement, application of soil additive @ 5kg per M2 and application of pesticides etc. Complete as directed by engineer-in-charge.
GROUND COVER PLANTATION (25 plants/M2) :Providing and Supply & plantation of ground cover plants (To be planted in garden soil over already dressed area ) development of bed, cultivation soil mixture and plantation of ground cover (as per plantation plan provided). Pesticides application to be done as per requirement, application of soil additive @ 5kg per M2 etc. Complete as directed by engineer-in-charge .
FICUS TOPIARY PLANTATION (4' to 5' height) : Providing and Supply & plantation of trees as per specified plantation plan. This will also include excavation of pits (90cm x 90cm x 90cm) ,mixing of soil additive @ 10kg per pit and existing soil, pesticides application and staking. Tree plantation should be carried out neatly accurately as per drawing etc. Complete as directed by engineer-in-charge.
ST.AUGUSTINE GRASS PLANTATION (40 nos. per m2)Supply & plantation of Grass (To be planted in existing soil and already dressed area ) Area dressing will be carried out on finally dressed leveled land as per site condition. Mixing the soil with soil additive @ 5kg per M2 etc. Complete as directed by engineer-in-charge.
CREEPER PLANTATION (PETREA ARBOREA) 3 nos per RMT, 1'Height) : supply and plantation of creeper plants (To be planted in garden soil over already dressed area ) Development of bed, plantation of creeper including Mixing the soil with soil additive @ 1 kg per RMT, steel wire (0.01 M3 per M2), with anchor fastener as per drawing etc. Complete as directed by engineer-in-charge.
Providing,supplying and spreading of SCREENED garden soil ( 450 mm th ) at site of work formed by mixing of approved materials obtained from outside with all lead and lifts, as per proposed or required depth, gradient/slope , degree of compaction (excluding cost of soil additives) etc. complete as per the directions of engineer in charge.
Designing, Providing and Supplying Drip Irrigation System capable of watering the Central Office Complex site admeasuring approx. 10 H consisting of the following works (The design of entire system shall be got approved before execution) :(i) Designing, providing and installing Hydro pneumatic system (pressure pump) so as to supply water to the entire site (The system shall be installed based on the tank at Central Service Yard).ii) Desiging, zoning of the entire site so as to minimise power consumption and water losses.iii) Providing, supplying and fixing adequate numbers of control valves so as to maintain and support the zoning as described above.iv) Providing, supplying & laying 20 to 75 mm HDPEpressure pipe (4kg / cm2) in the entire site as required for watering the plants, lawns etc. without disturbing permanent strucutres and pucca roads v) Providing, Supplying and laying 15-35 mm dia PVC flexible pipe to water the hedges, shrubs, shaded trees etc.vi) Providing, Supplying and laying 5mm dia PVC drip at all large trees as per requirement in design.vii) Providing, supplying and laying Pop-up which can cover 6.00 m. radially. The layout of pop-up shall be so designed, so that the flow from the adjoining pop-ups shall over lap each other by atleast 3.00 m.at all required locations.viii) Providing, Supply and laying sprinkler with a capacity to cover 6.00 m radially at all required locations.ix) Providing, Supplying and installing fertilizer mixing and distribution system by providing a 200 ltr. capacityvalves so as prepare dose of required mix and allow mixing to the distribution system.Commissioning the entire system.as per all the instruction given by the Architect and directed by the Engineer-in-charge
Labour for spreading and mixing loam or clay soil or river silt evenly over excavated area and levelling the same after clods etc. (Rate for one Cu. m. of soil) as directed by the Engineering- Charge
Providing Farm yard Manure of approved quality on site as directed by the Engineering- Charge
Labour for spreading and mixing the manure evenly with top 8 to 10 Cm. of prepared area at the rate of 5 C.mt per 100 Sq.m area .( Rate for one Cu. m. of manure) as directed by the Engineering- Charge
C-FIRE FIGHTING Supply, installation testing and commissioning of the following GI ‘C' class pipe as per IS1239 / 3589 with welded / flanged / screwed joints and with clamps,hangers, brackets / pipe supports as required including GI pipe of shorter lengths, tapering connecting pieces, short or long bends, couplers, unions, elbows, reducers, plugs, tees, etc. complete to make the system operative.The pipes will have to be suspended from PEB members / ceilings or fixed on wall as shown in drawings with anchor fastners. The work shall include making holes in structural member/ brick or RCC walls, slabs/ roofs and making good the damages by bringing to the original condition and painting two coats of approved shade(Post office red)of enamel paint over a coat of approved primer for over ground / overheads pipes.(Riser & Basement piping) as per all the instruction given by the Architect and directed by the Engineer-in-charge 150 mm
Supply, installation testing and commissioning of the following GI ‘C' class pipe as per IS1239 / 3589 with welded / flanged / screwed joints and with clamps,hangers, brackets / pipe supports as required including GI pipe of shorter lengths, tapering connecting pieces, short or long bends, couplers, unions, elbows, reducers, plugs, tees, etc. complete to make the system operative.The pipes will have to be suspended from PEB members / ceilings or fixed on wall as shown in drawings with anchor fastners. The work shall include making holes in structural member/ brick or RCC walls, slabs/ roofs and making good the damages by bringing to the original condition and painting two coats of approved shade(Post office red)of enamel paint over a coat of approved primer for over ground / overheads pipes.(Riser & Basement piping) as per all the instruction given by the Architect and directed by the Engineer-in-charge 100 mm
Supply, installation testing and commissioning of the following GI ‘C' class pipe as per IS1239 / 3589 with welded / flanged / screwed joints and with clamps,hangers, brackets / pipe supports as required including GI pipe of shorter lengths, tapering connecting pieces, short or long bends, couplers, unions, elbows, reducers, plugs, tees, etc. complete to make the system operative.The pipes will have to be suspended from PEB members / ceilings or fixed on wall as shown in drawings with anchor fastners. The work shall include making holes in structural member/ brick or RCC walls, slabs/ roofs and making good the damages by bringing to the original condition and painting two coats of approved shade(Post office red)of enamel paint over a coat of approved primer for over ground / overheads pipes.(Riser & Basement piping) as per all the instruction given by the Architect and directed by the Engineer-in-charge 80 mm
Providing and fixing Single headed internal hydrant having outlet of 63 mm dia(2.1/2”) N.B. hydrant (IS:5290) landing valve in SS / Gunmetal Morris Pattern instanteous coupling type with required hardwares. as per all the instruction given by the Architect and directed by the Engineer-in-charge
Providing & fixing 63mm dia RRL hose pipe of 15 mtr. Length, as per IS 636 TYPE A of approved pattern and size including SS / gun metal male and female Coupling as per all the instruction given by the Architect and directed by the Engineer-in-charge
Providing and fixing fire hose cabinet to house fire hydrant & hose, including all other related accerrories fabricated from M.S. sheet (16 Gauge) of fully welded construction having front doorwith locking arrangement, partially glazed with 4 mm thick glass. Cabinet shall be powder coated & painted with post office red colour to house the hydrant valve, 2 nos. hoses, hose reel, branch pipe & Fire extinguishers. The hose cabinet size is 1500 mm x 800 mm x 450 mm or as suitable. Cabinet shall be either wall or floor mounted with all fixing hardwaes as per all the instruction given by the Architect and directed by the Engineer-in-charge
Supplying & fixing first aid fire hose reel of braided rubber suitably reinforced 25 mm size 30 mtr standard length with tapering branch nozzle, 32 mm Pipe to connect to riser with cut off ball valve attachment. Hose to be fixed type wall mounted drum including fixing with anchor fasteners & bolts as per all the instruction given by the Architect and directed by the Engineer-in-charge
Providing, fixing and testing forged brass 25 mm dia screwed inlet.single acting air release valve with 25 mm dia ball valve on inlet side and pressure gauge with isolating cock. as per all the instruction given by the Architect and directed by the Engineer-in-charge
Providing and fixing SS /gunmetal branch pipe nozzle conforming to IS 903, suitable for instantaneous connections to hose coupling etc. asrequired as per all the instruction given by the Architect and directed by the Engineer-in-charge
Supplying and fixing specially designed SS / gunmetal orifice plates (minimum 6 mm plate thickness) on external & internal hydrant outlets of hydrant valves for reducing delivery pressureto 2.5 kg/ sq.cm at hydrant valve as per all the instruction given by the Architect and directed by the Engineer-in-charge
Supplying, installation testing and commissioning of the 'C’ class MS Pipe as per IS1239 for undegound installation with welded connection with tapering connecting pieces, short or long bends, specials like sockets, union nuts, elbows, plugs, tees etc. complete to make the system operative as required by LFA, the pipes will have to be laid and fixed in trenches. The scope shall also include excavation, backfilling of soil, providing, warpping and coating of pypkote (corrosion protection tape) with overlap of 15 to 20 mm) etc. complete. The scope shall also include hydraulic testing at 1.5 times working pressure before wrapping & coating. Size : 150 mm as per all the instruction given by the Architect and directed by the Engineer-in-charge
Supplying, installation testing and commissioning of the 'C’ class MS Pipe as per IS1239 for undegound installation with welded connection with tapering connecting pieces, short or long bends, specials like sockets, union nuts, elbows, plugs, tees etc. complete to make the system operative as required by LFA, the pipes will have to be laid and fixed in trenches. The scope shall also include excavation, backfilling of soil, providing, warpping and coating of pypkote (corrosion protection tape) with overlap of 15 to 20 mm) etc. complete. The scope shall also include hydraulic testing at 1.5 times working pressure before wrapping & coating. Size : 100 mm as per all the instruction given by the Architect and directed by the Engineer-in-charge
Providing and fixing hydrant stand posts of 80 mm dia. with flanges and accessories including supply & fixing of single headed yard hydrant 63 mm dia SS / G.M.valve with 2.1/2” ‘Morris’pattern instaneous couplings in the external courtyard conforming to IS:5290 including 2 coats of approved enamel paint (red) over a coat of primer,complete as per all the instruction given by the Architect and directed by the Engineer-in-charge
Providing & fixing 63mm dia RRL hose pipe as per IS 636 TYPE A of 15 mtr. standard length of approved pattern and size including SS / gun metal male and female Coupling as per all the instruction given by the Architect and directed by the Engineer-in-charge
Providing and fixing fire hose cabinet to house 2 nos., 15 mtr. hoses & related accessories, it shall be fabricated from M.S. sheet (16 Gauge) of fully welded construction having front door with locking arrangement, partially glazed with 4 mm thick glass.Cabinet shall be powder coated & painted with post office red colour. The size of the cabinet shall be 750 mm x 600 mm x 300mm as per all the instruction given by the Architect and directed by the Engineer-in-charge
Supplying and fixing 4 way Fire Brigade service inlet of size 150 mmdia. with 4 No. 63mm (2.1/2") size GM / SS 316 male outlets including metallic cover of mild steel and glass front, indicatorplates,150mm BFV, NRV, etc. complete as per all the instruction given by the Architect and directed by the Engineer-in-charge
Supplying and fixing 2 way Fire Brigade service inlet of size 100 mmdia. with 2 No. 63mm (2.1/2") size GM / SS 316 male outlets including metallic cover of mild steel and glass front, indicatorplates,100mm BFV, NRV, etc. complete as per all the instruction given by the Architect and directed by the Engineer-in-charge
Supplying & installing completely testing & commissioning of End suction centrifugal type main fire pump(electrical driven) for hydrant / sprinkler system with cast iron casing & bronze impeller & internal parts, etc. suitable for fire duty. The scope shall include coupling, coupling guard necessary base frame, foundation bolts, capable of discharging 2280 lt/min against 70 mtr. head. The scope shall also include electrical TEFC motor, operated on 3-ph, 440-V, 50 Hz, 2900/1500 RPM Syn.speed with ‘B’ class winding & shall be suitable for continuous duty. The pump shall be capable of giving not less than 150% discharge at ahead not less than 65% of the rated head. as per all the instruction given by the Architect and directed by the Engineer-in-charge
Supplying & installing completely testing & commissioning End suction centrifugal type main fire pump (diesel engine driven)with cast iron casing & bronze internal parts, complete with coupling, coupling guard necessary base frame,foundation bolts & capable of discharging 2280 lt/min against 70 mtr. head with suitable diesel engine of speed matching the pump speed ,auto start facility with battery & battery charger, nessesary wiring, fuel tank , suitable exhaust piping with insulation as per regulation. The pumpshall be capable of giving not less than 150% discharge at a head notless than 65% of the rated head. as per all the instruction given by the Architect and directed by the Engineer-in-charge
Supplying, installing, testing and commissioning of centrifugal vertical multistage / monoblock type jockey pump-motor having bronze impeller with discharge 180 lpm against 70 mtr. head with 3 phase, 415 V, 50Hz motor having 2900 RPM. The scope shall alsoinclude necessary coupling, coupling guard, base frame, foundation bolts, etc. complete as per all the instruction given by the Architect and directed by the Engineer-in-charge
Design, manufacture, supply ,installation, testing and commissioning of following MCC panels suitable for 415V, 3 phase, 4 wire, 50 hz power distribution system.the panel should be indoor,free standing, floor mounting, sheet metal clad, Cubicle, dead front, dust and vermin proof conforming to IP-55 enclosure, compartmentalized design fabricated out of 14 SWG sheet steel complete with Al busbars, separate earth busbar to be provided through out the length of the panel. The incoming and outgoing feeders shall be accommodated in a modular multi tier arrangement, adequate size cable alley, painting, earthing numbering, damper plate etc. as required . It shall include starters for above pumpsets, protections, all control wiring for auto operation of fire. It shall be BMS copatible & shall have required indications & annunciation. The panel shall include separate compartment as zone panel for annuncation with all indications, accessories, hardwares, internal wiring, control wiring, suitable size LT XLPE cable from panel to motor with end termination, etc. complete as per all the instruction given by the Architect and directed by the Engineer-in-charge
Supplying, installation testing and commissioning of the following ‘C’ class MS Pipe as per IS:1239 / 3589 for overground pipes within Pump house with flanged / welded joints and with clamps,hangers, brackets or pipe supports as required including pipe of shorter lengths,tapering connecting pieces, bends, union, elbows, reducers, plugs, Tees, bends,etc.Complete to make the system operative. The pipes will have to be laid on walls / floor or suspended from ceilings.The work includes makingholes in brick or RCC walls, slabs/ roofs and making good the damages by bringing to the original condition to the satisfaction of the Engineer in charge, painting two coats of approved shade(Post office red) of enamelpaint over a coat of approved primer. as per all the instruction given by the Architect and directed by the Engineer-in-charge 200 mm (6 mm thk )
Supplying, installation testing and commissioning of the following ‘C’ class MS Pipe as per IS:1239 / 3589 for overground pipes within Pump house with flanged / welded joints and with clamps,hangers, brackets or pipe supports as required including pipe of shorter lengths,tapering connecting pieces, bends, union, elbows, reducers, plugs, Tees, bends,etc.Complete to make the system operative. The pipes will have to be laid on walls / floor or suspended from ceilings.The work includes makingholes in brick or RCC walls, slabs/ roofs and making good the damages by bringing to the original condition to the satisfaction of the Engineer in charge, painting two coats of approved shade(Post office red) of enamelpaint over a coat of approved primer. as per all the instruction given by the Architect and directed by the Engineer-in-charge 150mm
Supplying, installation testing and commissioning of the following ‘C’ class MS Pipe as per IS:1239 / 3589 for overground pipes within Pump house with flanged / welded joints and with clamps,hangers, brackets or pipe supports as required including pipe of shorter lengths,tapering connecting pieces, bends, union, elbows, reducers, plugs, Tees, bends,etc.Complete to make the system operative. The pipes will have to be laid on walls / floor or suspended from ceilings.The work includes makingholes in brick or RCC walls, slabs/ roofs and making good the damages by bringing to the original condition to the satisfaction of the Engineer in charge, painting two coats of approved shade(Post office red) of enamelpaint over a coat of approved primer. as per all the instruction given by the Architect and directed by the Engineer-in-charge 100mm
Supplying, installation testing and commissioning of the following ‘C’ class MS Pipe as per IS:1239 / 3589 for overground pipes within Pump house with flanged / welded joints and with clamps,hangers, brackets or pipe supports as required including pipe of shorter lengths,tapering connecting pieces, bends, union, elbows, reducers, plugs, Tees, bends,etc.Complete to make the system operative. The pipes will have to be laid on walls / floor or suspended from ceilings.The work includes makingholes in brick or RCC walls, slabs/ roofs and making good the damages by bringing to the original condition to the satisfaction of the Engineer in charge, painting two coats of approved shade(Post office red) of enamelpaint over a coat of approved primer. as per all the instruction given by the Architect and directed by the Engineer-in-charge 80 mm
Supplying, installation testing and commissioning of the following ‘C’ class MS Pipe as per IS:1239 / 3589 for overground pipes within Pump house with flanged / welded joints and with clamps,hangers, brackets or pipe supports as required including pipe of shorter lengths,tapering connecting pieces, bends, union, elbows, reducers, plugs, Tees, bends,etc.Complete to make the system operative. The pipes will have to be laid on walls / floor or suspended from ceilings.The work includes makingholes in brick or RCC walls, slabs/ roofs and making good the damages by bringing to the original condition to the satisfaction of the Engineer in charge, painting two coats of approved shade(Post office red) of enamelpaint over a coat of approved primer. as per all the instruction given by the Architect and directed by the Engineer-in-charge 65mm
Providing, installing testing & commissioning of Foot valve; Size : 150 mm as directed by the Engineering- Charge
Providing, installing testing & commissioning of Foot valve; Size : 80 mm as directed by the Engineering- Charge
Supply and installation,testing and commisioning of CI Butterfly valves( heavy ) conforming to BS 5155 ,PN1.0 tested to 1.5 times workingpressue with necessary companion flanges,bolts, nuts, gasketpacking, support and any other spares, including indicator for open and shut position as per fire practice etc complete as per all the instruction given by the Architect and directed by the Engineer-in-charge 150mm
Supply and installation,testing and commisioning of CI Butterfly valves( heavy ) conforming to BS 5155 ,PN1.0 tested to 1.5 times workingpressue with necessary companion flanges,bolts, nuts, gasketpacking, support and any other spares, including indicator for open and shut position as per fire practice etc complete as per all the instruction given by the Architect and directed by the Engineer-in-charge 100mm
Supply and installation,testing and commisioning of CI Butterfly valves( heavy ) conforming to BS 5155 ,PN1.0 tested to 1.5 times workingpressue with necessary companion flanges,bolts, nuts, gasketpacking, support and any other spares, including indicator for open and shut position as per fire practice etc complete as per all the instruction given by the Architect and directed by the Engineer-in-charge 80mm
Supply and installation,testing and commisioning of CI Butterfly valves( heavy ) conforming to BS 5155 ,PN1.0 tested to 1.5 times workingpressue with necessary companion flanges,bolts, nuts, gasketpacking, support and any other spares, including indicator for open and shut position as per fire practice etc complete as per all the instruction given by the Architect and directed by the Engineer-in-charge 65mm
NRV conforming to IS 5312 (swing type) or to API 594/598 (dual platecheck type) with CI body & brass trim part, PN 1.0 having necessary companion flanges, CS hardwares. Gaskets, arrow indicating directionof flow, etc. complete. It shall be ISI Marked and approved make as per all the instruction given by the Architect and directed by the Engineer-in-charge 150 mm
NRV conforming to IS 5312 (swing type) or to API 594/598 (dual platecheck type) with CI body & brass trim part, PN 1.0 having necessary companion flanges, CS hardwares. Gaskets, arrow indicating directionof flow, etc. complete. It shall be ISI Marked and approved make as per all the instruction given by the Architect and directed by the Engineer-in-charge65 mm
Supply,installation testing and commisioning pressure switch with required control wiring as per all the instruction given by the Architect and directed by the Engineer-in-charge
100 mm dial Pressure gauge with Syphon tubing, isoltaion valve & mounting accessories complete Range : 0 - 15 kg/sq.cm. as per all the instruction given by the Architect and directed by the Engineer-in-charge
Supply, installation, testing & commissioning of Rubber bellows on suction & discharge side of pump conforming to EJMA with allhardwares, companion flanges & gaskets, etc. as per all the instruction given by the Architect and directed by the Engineer-in-charge 150mm
Supply, installation, testing & commissioning of Rubber bellows on suction & discharge side of pump conforming to EJMA with allhardwares, companion flanges & gaskets, etc. as per all the instruction given by the Architect and directed by the Engineer-in-charge 65mm
D-IRRIGATION PVC Pipes with all PVC Accessories Like Tee, Bend, Reducer, Solvent etc. All Fittings should be minimum pressure as per given below for respective sizes.- Supreme/Finolex/Astral as per all the instruction given by the Architect and directed by the Engineer-in-charge PVC Pipe 90mm x 6 kg/cm2
PVC Pipes with all PVC Accessories Like Tee, Bend, Reducer, Solvent etc. All Fittings should be minimum pressure as per given below for respective sizes.- Supreme/Finolex/Astral as per all the instruction given by the Architect and directed by the Engineer-in-charge PVC Pipe 75mm x 6 kg/cm2
PVC Pipes with all PVC Accessories Like Tee, Bend, Reducer, Solvent etc. All Fittings should be minimum pressure as per given below for respective sizes.- Supreme/Finolex/Astral as per all the instruction given by the Architect and directed by the Engineer-in-charge PVC Pipe 63mm x 6 Kg/cm2
PVC Pipes with all PVC Accessories Like Tee, Bend, Reducer, Solvent etc. All Fittings should be minimum pressure as per given below for respective sizes.- Supreme/Finolex/Astral as per all the instruction given by the Architect and directed by the Engineer-in-charge PVC Pipe 50mm x 6 Kg/cm2
PVC Pipes with all PVC Accessories Like Tee, Bend, Reducer, Solvent etc. All Fittings should be minimum pressure as per given below for respective sizes.- Supreme/Finolex/Astral as per all the instruction given by the Architect and directed by the Engineer-in-charge PVC Pipe 40mm x 6 Kg/cm2
Gear Driven Pop Up Sprinkler 8- 14 mtr Radius with check valve, Inbuilt pressure regulator & on off feature from top. as directed by the Engineering- Charge
Swing Joint 3/4" as directed by the Engineering- Charge
P.P. Clamp Saddle 63/50/40 x 3/4" -PN 6 as directed by the Engineering- Charge
4" Pop Up Spray Sprinkler - with check valve, inbuilt pressure regulator & low flow indicator, having 10'/ 12'/ 15'/18' Variable Arc Spray Nozzle as directed by the Engineering- Charge
Swing Joint 1/2" as directed by the Engineering- Charge
P.P. Clamp Saddle 63 / 50 / 40 x 1/2" as directed by the Engineering- Charge
PVC Ball Valve 63 mm as directed by the Engineering- Charge
Clamp Saddle 90/75 mm x 2 , 1.5, 1.25" as directed by the Engineering- Charge
12" Rectangle Valve Box as directed by the Engineering- Charge
Hydrant 3/4" as directed by the Engineering- Charge
Hydrant Opener 3/4" as directed by the Engineering- Charge
Swiel Elbow 3/4" as directed by the Engineering- Charge
P.P. Clamp Saddle for Hydrant as directed by the Engineering- Charge
Round Valve Box 10" as directed by the Engineering- Charge
Drip In Line Lateral Pipe 16 mm X 4kg , 4 LPH, 45 cm (Brown) as directed by the Engineering- Charge
Drip Online lateral Poly Pipe 16mm X 4 kg (Brown) as directed by the Engineering- Charge
Take off Assembly (PP Clamp Saddle40mm x 1/2" + SCH 40 1/2" Pipe + 17mm Barbed x 1/2" Male Tee) Lateral end stop as directed by the Engineering- Charge
Flush Valve40 mm as directed by the Engineering- Charge
Tee / Elbow 17 mm as directed by the Engineering- Charge
Lateral Hold Stake as directed by the Engineering- Charge
Pumping System -Pump 6 LPS 42 Meter ( 1 W + 1 Standby) Head with Pressure Tank, Header, Pressure Switch, Butterfly Valve, NRV with all Accessories complete as directed by the Engineering- Charge
Filtration Unit - Fully Automized Screen Filter 3" worked with Pressure Diffential and Electrical if required as directed by the Engineering- Charge
Hydro / Water Meter 3" Inch with In built Valve with 24 VAC Coil with Flow digital out put as directed by the Engineering- Charge
Header for Pump, Filter Hydro Meter, PRV etc as directed by the Engineering- Charge
Double Acting Air Release Valve 1" - Kinetic as directed by the Engineering- Charge
Round Valve Box 10" as directed by the Engineering- Charge
Pressure Gauge-Glycerin filled as directed by the Engineering- Charge
P.P. Clamp Saddle 160 to 90 x 2, 1" for AIR Valve as directed by the Engineering- Charge
IR-3"-13Q-Y-P-BP-PP Surge Anticipation cum Pressure Relief Valve with G I Pipe 6 Meter as directed by the Engineering- Charge
Controller ESP8 LX ME with 4 Programme, 8 Start Time Expandable upt 48 Station as directed by the Engineering- Charge
Solenoid Valve 2" Glass Filled Nylon as directed by the Engineering- Charge
Pressure Regulating dial ( 0 to 5 Bar) as directed by the Engineering- Charge
Controlled Automized Cable 12/1 Paige/ Rainbird Make - Common as directed by the Engineering- Charge
Controlled Automized Cable 14/1 Paige/ Rainbird Make - Hot as directed by the Engineering- Charge
Rain Sensor with Bracket as directed by the Engineering- Charge
Splice Kit as directed by the Engineering- Charge
Servo Stabilizer 1 KVA as directed by the Engineering- Charge
6" Round Valve Box as directed by the Engineering- Charge
Erection of Irrigation Hardware - Pipes, Irrigation Devices-Sprinklers, Drip, Valves, Automation Components-Valves, Controllers, Cables, Pumping System, Filtration Unit. as per all the instruction given by the Architect and directed by the Engineer-in-charge Excavation & Back Filling Installation Charges - Laying of Pipes, Sprinklers, Drip Lines, Valves, Cables, Pump Station and any other required fixture to complete the system and make it operational.as directed by the Engineering- Charge
Providing and erecting XLPE(IS:7098)(I)-88 ISI armoured cable multistrand Copper conductor for 1.1 KV. to be laid on wall with necessary clamps or in existing trench / pipe at road crossing or floor of following size of cables. (A) 4 core 2.5 Sq. mm as directed by the Engineering- Charge
Providing and, fixing heavy duty flange type brass cable gland with rubber ring for PVC insulated armoured cable complete with out going tails, insulating tape etc for following size of cables. (a) 2 to 4 core 2.5 Sq. mm as directed by the Engineering- Charge
Solderless crimping type Copper lugs conforming to IS suitable for cable of following size evenly crimped with high pressure tool & connected to switchgear terminals with brass/cadmium plated nut bolts in an approved manner. (A) 1.5/2.5 to 6 Sq.mm as di as directed by the Engineering- Charge
Providing and erecting XLPE(IS:7098)(I)-88 ISI armoured cable multistrand Copper conductor for 1.1 KV. to be laid on wall with necessary clamps or in existing trench / pipe at road crossing or floor of following size of cables. (A-1) 4 core 4 Sq. mm as directed by the Engineering- Charge
Providing and, fixing heavy duty flange type brass cable gland with rubber ring for PVC insulated armoured cable complete with out going tails, insulating tape etc for following size of cables. (b) 2 to 4 core 4 Sq. mm as directed by the Engineering- Charge
Solderless crimping type Copper lugs conforming to IS suitable for cable of following size evenly crimped with high pressure tool & connected to switchgear terminals with brass/cadmium plated nut bolts in an approved manner. (A) 1.5/2.5 to 6 Sq.mm as directed by the Engineering- Charge
Providing and erecting XLPE (IS:7098)(I)-88 ISI armoured cable multistrand Aluminium conductor for 1.1 KV. to be laid on wall with necessary clamps or in existing trench / pipe of following size of cables (d) 4 core 16 Sq. mm as directed by the Engineering- Charge
Providing and, fixing heavy duty flange type brass cable gland with rubber ring for PVC insulated armoured cable complete with out going tails, insulating tape etc for following size of cables. (e) 2 to 4 core 16 Sq. mm as directed by the Engineering- Charge
Solderless crimping type Aluminium lugs conforming to IS suitable for cable of following size evenly crimped with high pressure tool & connected to switchgear terminals with brass/cadmium plated nut bolts in an approved manner. (C) 16 Sq.mm. as directed by the Engineering- Charge
Making trench in Hard Murrum / Tar Road of suitable width of 90 cms or required depth for laying any size of cable or locating the fault all over the run and back filling the same and making the surface as normal ground.as directed by the Engineering- Charge
Covering of cable with second class bricks or cement tiles laid cover the cable crosswise & also on both sides with covering of 7. 5 Cms. layer of sand above & below cable (16 bricks per meter) as directed by the Engineering- Charge
Supply, Installation, testing and commissioning of Bollard LED fittings mounted on 60 cms high rotomoulded LLDPE pillar duly grouted on a concrete base by means of four nos of M8 X 75 mm studs with necessary base ring. Cat-III as directed by the Engineering- Charge
Supply, Installation, testing and commissioning of Step Light having fibre reinforced plastic housing. Cat-III as directed by the Engineering- Charge
Supply, Installation, testing and commissioning of Post Top Lantern LED fitting comprises of 650 MM TOP Diameter, 120 degree beam angle with 3 Nos. Supporting Ribs proposed for Gardens & Promenade as equi to LANCE made LL41C-030-CW-XXXXas directed by the Engineering- Charge Cat-III
Supplying & erecting Galvanized iron pipe post “B” class 88.9 mm O.D 4 mtr. Long duly painted with two coats of aluminium paint complete with metallic base plate of 300 mm x 300 mm x 4mm thick for using as a compound light pole with approx. weight 32 Kg. as directed by the Engineering- Charge
Supply, Installation, testing and commissioning of 7W LED tree up lighter Eq. To Hybac Cat. No. - HLO-5910 as directed by the Engineering- Charge
Supply, Installation, testing and commissioning of 6W LED surface wall light (IP54) Eq. To Hybac Cat. No. - HLO-5377 as directed by the Engineering- Charge
Supply, Installation, testing and commissioning of Flood Light (IP-65), Surge -4KV (For sports area) (c) Above 100 watts to 120 watts. Cat-III as directed by the Engineering- Charge
Supply, Installation, testing and commissioning of 8.5 MTR Height single arm GI Pole (for Flood Light at sports area) as per specification, drawing and relavent IS code 410-SP-16. Scope shall cover supply and installation of pole, cross arm, suitable size junction box, pipe for cable, wiring, earthing etc. to complete the job. Scope doesn't cover light fixture.as directed by the Engineering- Charge
Supply, Installation, testing and commissioning of Flood Light (IP-65), Surge -4KV (For sports area) (c) Above 70 watts to 90 watts. Cat-III as directed by the Engineering- Charge
Supplying & erecting approved make SMC press moulded composite FRP. loop-in, loop-out approx. 2mm thick box complete with bakelite connector strip 4way & hinged doors having locking arrangements with mounting clamp with nuts, bolts & washers suitable for erection on pole with cable clamps& earth bolt of following size of box.(Below flood light pole at sports area) (a) 300mm x 200mm x 100mm [deep] as directed by the Engineering- Charge
Supply, Installation, testing and commissioning of 12 MTR High-Mast Pole as per specification, drawing and relavent IS. Scope shall cover supply and installation of pole, suitable size junction box, pipe for cable, wiring, earthing etc. to complete the job. Scope doesn't cover light fixture. as directed by the Engineering- Charge
Supply, Installation, testing and commissioning of above 150 to 240 watts Cat-III (for high mast). Flood light as directed by the Engineering- Charge
Providing and erecting Epoxy Outdoor / Indoor end termination Kit suitable for LT PVC insulated armoured cable1.1 KV grade complete with ferrule bushing and accessories and suitable clamps duly erected and connected to the supply for all cores cables of following size. (A) 2.5 to 16 Sq. mm as directed by the Engineering- Charge
Supply, fabrication and installation of structural steel required for cable tray support on wall with anchor fastner / nuts and bolts , including required welding/ cutting/ grinding shall be done to complete the job using ISA/ISMC/MS flat. The job also includes to paint the structure after surface cleaning with two coats of red oxide and two coats color of enamel paint as approved and recommanded by consultant/ client. as directed by the Engineering- Charge
Providing and laying glazed tiles 400 mm x 800 8 to10 mm thick of approved make, colour and pattern in skirting, risers of steps and dado on 10 mm thick cement plaster 1:3 (1 cement : 3 coarse sand) and jointed with white cement slurry as directed by the Engineering- Charge
providing 15mm thick cement plaster in single coat on fair side of brick / concrete wall for interior plastering up to floor two level finished even and smooth in C M 1:4 ( 1 cement 4 coarse sand) including finishing with a flouting coat of neat cement slurry with Niru finish complete. For ground floor and first floor as directed by the Engineering- Charge
Providing and laying glazed tiles 400 mm x 800 8 to10 mm thick of johnson, nitko, simpolo make, colour and pattern in skirting, risers of steps and dado on 10 mm thick cement plaster 1:3 (1 cement : 3 coarse sand) and jointed with white cement slurry as directed by the Engineering- Charge
Labour work of edge polishing work on kota stone/Granite stone as per instructions given by the Architect and instruction given by the Engineer-in-charge as directed by the Engineering- Charge
Wall painting with one coat of BIRLA WHITE primer & 2 coat of BIRLA WHITE putty & with 2 / 3 coats of plastic emulsion paint of Asain royale, ICI velvet touch brand, Berger , Nerolac or equivalent and manufacture on wall surfaces to give an even shade including thouroughly brushing the surface free from mortar droppings and other foreign matter and sand papered smooth. as directed by the Engineering- Charge
Labour work of edge polishing work on kota stone/Granite stone as per instructions given by the Architect and instruction given by the Engineer-in-charge
Providing Material and Labour fixing mirror polished telephone black granite slab for platform for wash basin and thickness minimum 20 mm with top and exposed edge polished and fixing in wall including making groove in wall making it good by filling cement mortar 1:3 including cutting holes for wash basin as directed as directed by the engineer-in-charge
Providing Material and Labour for fixing mirrror polished granite (TELEPHONE BLACK GRANITE or GRANITE APPROVED BY ARCHITECT) cladding on openings of width 125 mm and thickness minimum 20 mm with top and both exposed edge polished and joining with chemical adhesives of bal, weber or equivalent make after driving holes in stone at 500 mm c/c and screwing and fixing with araldite as per the drawing and as per approved by the Architect.FOR TOILET DOORS as directed by the Engineering- Charge
Providing Material and Labour for fixing mirrror polished granite (TELEPHONE BLACK GRANITE or GRANITE APPROVED BY ARCHITECT) cladding on openings of width 125 mm and thickness minimum 20 mm with top and both exposed edge polished and joining with chemical adhesives of bal, weber or equivalent make after driving holes in stone at 500 mm c/c and screwing and fixing with araldite as per the drawing and as per approved by the Architect.ON TOP OF TOILET PARTITION WALLS as directed by the Engineering- Charge
Demolition of Brick work and stone masonry including stacking of serviceable materilas and disposal of unserviceable materials with all lead and lift.(ii) In Cement Mortar. as directed by the Engineering- Charge
Dismentaling tiled of stone floors laid in mortar including stacking of serviceable materilas and disposal of unserviceable materials with all lead and lift. as directed by the Engineering- Charge
Dismentaling of sheet roofing including ridges, Hips, Valleys, Gutters etc. stacking of serviceable materilas and disposal of unserviceable materials with all lead and lift.(i) G.I.sheet roofing. as directed by the Engineering- Charge
Dismentaling of sheet roofing including ridges, Hips, Valleys, Gutters etc. stacking of serviceable materilas and disposal of unserviceable materials with all lead and lift.(ii) A.C. sheet roofing. as directed by the Engineering- Charge
Providing & fixing in position 0.5mm thick galvalume Pre-coated roof sheet precoated of standard company or approved equvelant quality including necessory bolt, washers etc. Complete as per design. as directed by the Engineering- Charge
Providing and fixing FRP gutter of size approximately 40 cm x 70 cm and 3 mm thickness and joining each other with silicon, hardner, GP resin, glasswool etc and fixing to the main structure with angle section of 50mm x 50 mm size at 0.75 mt c/c distance etc complete as per the design given by the Architect as directed by the Engineering- Charge
Applying priming coat over new steel and other metel surface after and including preparing the surface by throughly cleaning, oil,grease, dirt and other foreign matter and scoured with brushes fine steel wood, scrapers and sand paper with ready mixed priming paint brushing red lead.as directed by the Engineering- Charge
Painting two coats (excluding priming coat) on new steel and other metal surface with enamel paint, brushing, interior to give an even shade including cleaning the surface an even shade including cleanicn the surface of all dirt, dust and other foreign matter. as directed by the Engineering- Charge
Dismentalings cement asbestos hard board in ceiling or partition walls, wooden trellies work including trellies work including frames ,stacking of serviceable materilas and disposal of unserviceable materials with all lead and lift. as directed by the Engineering- Charge
Providing and fixing window having extruded aluminum Colour anodized section frame main outer size 95mm x 24mm x 1.17mm (of Jindal Section no:2459 @ wt.of 0.738 Kg/mt), horizontal Three track member size 92mm x 31.75mm x 1.30mm (of Jindal Section no:8688,@ Wt.1.07 Kg/mt), vertical member of size 92mm x 31.75mm x 1.50mm (of Jindal Section no:8933,@ Wt. 1.06 Kg/mt) with sliding shutters of horizontal member size 40 mmx18mm x1.29mm (of Jindal Section no:8947@ wt.of 0.456 Kg/mt), vertical member of size 40mm x 18mm x 1.29 mm (of Jindal Section no:8949 @ wt.of 0.456Kg/mt/ with two sliding shutters with 5 mm thick transparent bronze colour tinted float glass cover full area of window and one shutter with SS 316 grade jali (mosquito net) cover half of the window with powder coated aluminum fittings and fixtures and transparent silicon sealant glass fixing to frame as per details etc as directed by the Engineering- Charge
Providing and fixing M.S. grills of required pattern to wooden frames of windows etc. with M.S. flats at required spacings and frame alround, square or round bars with round headed bolts and nuts or by screws (A) Plain Grill. as directed by the Engineering- Charge
Providing and fixing mirrror polished KANDLA GREY cladding on openings and thickness minimum 20 mm with top and all exposed edge polished and joining with chemical adhesives of bal, weber or equivalent make after driving holes in stone at 500 mm c/c and screwing and fixing with araldite as per the drawing and as per approved by the Architect. as directed by the Engineering- Charge
Providing and Filling the joint with epoxy grout 3mm width and 8mm detpth of as per instruction & approved quality by Engg in charge.
Providing Material and Labour for fixing in position openable door with fixed single shutter and fixed to marble with hinges and shutter made of 32 mm thick water proof flush door of greenlam, everest, kitply or equivalent make with 3 mm thick aluminium composite panel of viva, euro, flexi bond or equivalent make of any shade on both the sides as well as edges with necessary hardware of high grade anticorrosive AISI 316 matt stainless steel of kich/arc/dunex make like handle (200 mm) both side, dead lock, aldrop both side, door stop, stopper, hinges with necessary silicon and spacer tape with all labour etc complete as per the drawing provided by the architect
Providing & fixing wall hung type white E.W.C - `P’ trap with PVC pan connector, CI chair, soft seat cover, C.P. brass hinges, including inbuilt jet spray, all internal fittings, rubber buffers, C.P. nuts, bolts, brackets, etc all accessories for complete installation, making holes in walls, floors, & making good. (Model : Duravit : Dcode ) as directed by the Engineering- Charge
Providing & fixing of slim dual flush concealed tank with drain pipe connection set , flush plate & required accessories & civil work for complete installation (Model : Jaquar - CIB WHT-31801011XP + CIS CHR 31185210X) as directed by the Engineering- Charge
Providing and fixing White glazed vitreous Wash Basin Oval /Round table top / under counter type with supporting M.S. or C.I. Brackets & with rubber adapter for waste connection and waste coupling. comp. etc. (Model : Jaquar CNS WHT WB03) as directed by the Engineering- Charge
Providing & fixing of 32 mm CP concealed Metropol Flush Valve with round flange, & required accessories & civil work for complete installation. (Model : Jaquar FLV-1085) as directed by the Engineering- Charge
Providing & fixing of 25 mm CP concealed quarter turn flush cock with operating lever,wall flange, required accessories & civil work for complete installation. (Model : Jaquar CON-1081A) as directed by the Engineering- Charge
Providing and fixing Single lever basin mixer with 450 mm braided hoses (Model : Jaquar FLR-5001B) as directed by the Engineering- Charge
Providing & fixing of 15 mm CP bib cock with wall flange and complete., for the following sizes. (Model : Jaquar CON 047KN) as directed by the Engineering- Charge
Providing and fixing 32 mm CP bottle trap with extension piece & wall flange complete. (Model : Jaquar ALD 769L250X190) as directed by the Engineering- Charge
Providing and fixing grab bar fabricated from 300 mm long stainless steel tube in bath room with non slip gripping surface, polished wall flange at end of bars with heavy duty anchor fasteners & accessories. (Model : Jaquar AKP 35701P) as directed by the Engineering- Charge
Providing & fixing in position best Indian make surface mounted CP toilet paper holder complete in all respects including cutting and making good the walls etc. (Model : Jaquar AKP 35751P) as directed by the Engineering- Charge
Providing & fixing in position 15 mm C.P. brass 2 way bib cocks of best quality (Model : Jaquar CON041KN) as directed by the Engineering- Charge
Providing & fixing of Hand Shower (Health Faucet), ABS body, Rmt Long pvc Tube and Wall Hook accessories to complete the item. (Model : Jaquar ALD CHR 583) as directed by the Engineering- Charge
Providing & fixing 15mm C.P. brass angle valve with C.P. with wall flange complete, including cutting and making good the wall where required. (Model : Jaquar CON 059KN) as directed by the Engineering- Charge
Providing & fixing Glass liquid soap container of best quality. (Model : Jaquar CAN 1135N) as directed by the Engineering- Charge
Providing & fixing of 20 mm CP concealed stop cock with wall flange and complete. (Model : Jaquar CON 089KN)as directed by the Engineering- Charge
Providing and fixing of electrical instantaneous type water Electric Geyser (Energy efficient) of approved make - 6 ltr. as directed by the Engineering- Charge
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes & fittings conforming to ASTM D-2846 SDR 11 upto 2" & Sch. 40 above 2" having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings including fixing the pipe with clamps at 1.00m spacing. Size 15 mm as directed by the Engineering- Charge
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes & fittings conforming to ASTM D-2846 SDR 11 upto 2" & Sch. 40 above 2" having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings including fixing the pipe with clamps at 1.00m spacing. Size 20 mm as directed by the Engineering- Charge
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes & fittings conforming to ASTM D-2846 SDR 11 upto 2" & Sch. 40 above 2" having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings including fixing the pipe with clamps at 1.00m spacing. Size 25 mm as directed by the Engineering- Charge
Providing and fixing uPVC pipes & fittings conforming to ASTM D-1785 Sch. 40 for cold water supply including fittings, fixing the pipe in trenches, with clamps at 1.00m spacing. This includes jointing of pipes & fittings and testing of joints complete as per direction of engineer in charge. Size : 75 mm
Providing fixing, testing and commissioning in position 3 RmtSWR PVC PIPE TYPE-B self fit pipe for soil/waste/vent, comforming to IS:13592 including all fittings such as bends, junctions, inspection doors, offests, cowl, access pieces/clean out plugs, clamps /supports/ hangers etc. jointing with PVC Adhesive joints including cutting holes in walls and making good the same. (Inside the Building i.e. Internal TOILET & basement) Size : 110 mm as directed by the Engineering- Charge
Providing and Fixing Mirror as per design and drawing of Architect with required fittings etc complete. as directed by the Engineering- Charge