| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance PP 32 MAURYA ENCLAVE PITAMPURA CHAITANYA CONSTRUCTION CO PP 32 MAURYA ENCLAVE PITAMPURA DELHI NORTH WEST DELHI DELHI 110034 | NORTH WEST DELHI | DELHI | 110034 | Admitted-Finance |
| 2 | Admitted-Finance | Admitted-Finance |
| 3 | Not Admitted-Fee/PreQual/Technical | Not Admitted-Fee/PreQual/Technical Not Complied with technical specification |
| 4 | Not Admitted-Fee/PreQual/Technical SHOP NO 55 GROUND FLOOR ROHINI SECTOR 7 NAHARPUR FLOOR HARLAL MARKET NAHARPUR SECTOR 7 DELHI OPP GOYAL GARMENTS VILLAGE TOWN DELHI CITY DELHI | Not Admitted-Fee/PreQual/Technical Not Complied with technical specification |
Tender Value
Refer Docs
EMD Value
₹22,800
Closing Date
23 Jun 2022, 11:30 amClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
EE(EnM)M-11
Apollo Booster Pumping Station Sarita Vihar New Delhi - 110076
Electrification of B-1 BPS Vasant Kunj along with Water Emergency and Kishangarh Village BPS under Mehrauli Constituency AC-45.
2022_DJB_224257_9
NIT No. 05/EE(EnM)M-11/2022-23
Open Tender
Miscellaneous Works
Works
30 days
EE(EnM)M-11
Please refer Tender documents.
3 documents required · 3 mandatory
₹500
Delhi Jal Board
₹22,800
14 Sept 2022
14 Jun 2022
23 Jun 2022
14 Jun 2022
23 Jun 2022
14 Jun 2022
120 days
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium steel conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.(DSR 2018 Item No. 1.3.3) Group-C
Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed steel conduit along with 1 No 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required. (DSR 2018 Item No. 1.5)
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required.(DSR 2018 Item No. 1.31)
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 A & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required.(DSR 2018 Item No. 1.32)
Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.(DSR 2018 Item No. 1.25).
Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required(DSR 2018 Item No. 1.26)
Supplying and fixing of following sizes of steel conduit along with accessories in surface/recess including painting in case of surface conduit, or cutting the wall and making good the same in case of recessed conduit as required, 25mm Size. (Item Code-1.20.2)
Wiring for circuit/ sub main wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required. 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire(DSR 2018 Item No.1.14.2)
Wiring for circuit/ sub main wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required2 X 4 sq. mm + 1 X 4 sq. mm earth wire(DSR 2018 Item 1.14.3)
Wiring for circuit/ sub main wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required2 X 10 sq. mm + 1 X 6 sq. mm earth wire(DSR 2018 Item 1.14.5)
Providing and fixing following capacity disconnector fuse ,switch unit inside the existing panel board with ISI marked HRC fuses including drilling holes in cubicle panel, making connection, etc. as required 63 A TP&N (DSR 2018 Item 2.1.2)
Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/ RCCB/ Isolator) 12 way Double door (DSR 2018 Item 2.3.3)
Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, “C” curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required Single Pole(DSR 2018 Item No. 2.10.1)
Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, “C” curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Double Pole(DSR 2018 Item No. 2.10.3
Supplying and fixing following rating, double pole,( single phaseand neutral), 240 V, residual current circuit breaker ( RCCB), having a sensitivity current 30 mA in existing MCB DB complete with connection, testing and commissioning etc. as required. 40 A (DSR 2018 Item No. 2.14.2)
Supply of LED street light 30 W (± 5%) pressure die cast aluminium housing with IP 66 deg. Of protection Make: Orient /havells /approved make in DJB
Supply of LED street light 70 W (± 5%) pressure die cast aluminium housing with IP 66 deg. Of protection Make: Orient/ havells /approved make in DJB
Supplying and fixing of 32 mm dia X 2.00 metres long G.I. pipe (medium class) bracket for mounting of fluorescent / HPMV / HPSV street light fitting on pole including bending the pipe to the required shape, 2 nos 40 mm X 3 mm flat iron clamps with nuts, bolts and washer, painting the flat iron with primer and finish paint etc. as required (DSR 2018 Item 12.34)
Supply of LED Batten light 20 watt LED batten type. Make Orient / Havells/ approved make in DJB
Supplying and fixing 3 pin, 5 A ceiling rose on the existing junction box/ wooden block including connections etc. as required (DSR 2018 Item 1.33)
Supply of 450 mm sweep heavy duty exhaust Fan. Make: Orient/havells/ approved make in DJB.
Supply of ceiling fan 1200 mm sweep( Energy saver) Make: Orient havells /approved make in DJB.
Supply of 600 mm Air Circulator 24, fan Make: Orient/havells/ approved make
Installation, testing and commissioning of pre-wired, fluorescent fitting / compact fluorescent fitting of all types, complete with all accessories and tube/lamp etc. directly on ceiling/ wall, including connections with 1.5 Sq. mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required.(DSR 2018 Item No. 1.41)
Installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length (upto 30 cm) with 1.5 Sq. mm FRLS PVC insulated, copper conductor, single core cable etc. as required. (DSR 2018 Item No. 1.44)
Installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required upto 450 mm sweep. (DSR 2018 Item 1.50.1)
Installation, of 600 mm Air Circulator 24, fan, including making good the damage, connection, testing, commissioning etc. as required upto 600 mm
Loading, unloading by heavy labour and cartage up to site i/c exhaust fan, celing fan, air circulator fan, street light etc. as per market rate.
P.K. Electricals
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .