Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹43.8 LAccepted-AOC 9 NAROTTAM KUNJ MADHU NAGAR AGRA CANTT 282001 | AGRA | UTTAR PRADESH | 282001 | L1 | Accepted-AOC being L1 | |
| 2 | L2₹48.9 L+₹4.9 L (11.2%)Rejected-Finance | L2 | Rejected-Finance Being other than L1 | |
| 3 | L3₹60.4 L+₹16.5 L (37.5%)Rejected-Finance | L3 | Rejected-Finance Being other than L1 |
Tender Value
₹44 L
EMD Value
₹88,000
Closing Date
25 Oct 2023, 6:00 pmClosed
GE (East) Agra
Garrison Engineer (East) Agra, Military Engineer Services, Gwalior House, 62 Taj Road Agra Cantt-282001
SPECIAL REPAIR/REPLACEMENT TO DG SET 320 KVA CAPACITY AT TL GP OF 509 ABW AGAINST BER (SM/MES NO 171283) AND PROVN OF 01 X OPEN BATHING POINT (ALONGWITH BOUNDARY WALL AND COVER SHED) NEAR BLDG NO P-05 OF 6 PARA (SF) UNDER GE(EAST) AGRA
2023_MES_620917_1
9599/E8
Open Tender
Miscellaneous Works
Item Rate
180 days
AGRA (UP)
Please refer tender documents
10 documents required · 10 mandatory
₹500
GE (East) Agra
₹88,000
Yes
1 Dec 2023
27 Sept 2023
1 Nov 2023
27 Sept 2023
25 Oct 2023
11 Oct 2023
Amount
Supply, installation, commissioning and testing (load trail) of Diesel Engine driven Generating set of capacity 320 KVA 415 Volt 3 phase 4 wire system complete with acoustic enclosure canopy floor mounted with control panel to ensure pollution free complying with all latest CPCB IV norms for pollution and noise with the following:-
(A) Diesel engine of required capacity 6 cylinder vertical 4 stroke electric start,heavy duty,water cooled rediator and cooling fan system, for continious duty with overload capacity of 10% for one hour in any tweleve hours duration confirming to IS:10002/BS: 5514 / ISO:3046 and comprising the following:- (i) The engine shall be supplied with Electronic Governor as per ISO 8528. (ii) Suitable coupling & guard. Fly wheel with starting ring and self starter. (iii) Fuel pump with pre and MICRO fuel filter. (iv) Fuel & lub oil filters fuel hoses. (v) Water pump and lub oil pump. (vi) Electric starting system with battery charging alternator and axial type starter motor including adequate number of high capacity maintenance free lead acid battery 180 AH 12 Volt as per manufactures requirement including inter connecting copper cable with terminal complete. (vii) Suitable designed fuel tank with level indicator marked in Ltrs and silencer. (viii) Suitable designed silencer. (ix) Engine safety against low lubnricating oil pressure and high water pressure. (B) Engine instrument panel comprise with the following:- (i) Starting switch with key / Push buttons (ii) Water temperature gauge. (iii) Lube oil pressure gauge. (iv) Digital type meter for measuring and display of amperage,voltage,PF, frequency RPM and KWH. (v) Indicating lamps. (vi) Safety alarm against high water temperature and low lunricating oil pressure. (C) Self exciting,self regulating brushless alternator rated for 320 KVA (256KW) at the speed of 1500 RPM at 415 Volts,50 Hz three phase 4 wire system with advance electronic voltage regulators to ensure high voltage accuracy with +/- 1% with class H insulation and SPDP enclosures directly coupled with the engine through flexible coupling and conforming to IS -13364 complete - 01 No. (D) Common fabricated base frame for engine and alternator made from structural channel/T section/ angle iron etc duly installed on and including suitable jerk proof PCC foundation 1:2:4 type B1 using 20 mm graded stone aggregate including adequate number of suitable anti vibration pads all as per the recommendation of the manufactures, height of the plinth should not be 0.60 mtr from GL (cost of PCC foundations, excavation earth work and anti vibration pads included in the quoted rates).
Supply, laying fixing in repair and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 240 sq mm 3.5 core complete all as specifed and directed.
M&L excavation in trenches in soft/loose soil N. exc 1.5 Mtr wide and not exc. 1.5 Meter deep and getting out including forming bottom surface for laying of cable complete all as specified and directed.
M&L returning filling including spreading, leveling, watering and well ramming in layers not exc 25 cm thick complete all as specifed and directed.
M&L removing surplus soil to a distance n.exc 50 Mtr and depositing where directed at a level n.exc 1.5 mtr above the starting point complete all as specifed and directed.
Supplying and laying sand cushioning for cable protection in trenches /filling in ducts at Sub Stations complete all as specified and directed.
Supplying and laying in replacement bricks old size sub class ‘B’ laid flat across the cable with length of whole brick for protection of cable complete all as specified and directed.
M&L for earthing complete with galvanized earth plate electrode 600 x 600 x6mm thick burned directly in ground ( earth pit not less than 2.5 M below normal ground level ) with top edge of the plate not less than 1.75 M below normal ground level connected to and including galvanized steel Strip of size 32 x 4 mm as earth lead Earth plate to bldg test point including 40mm GI light grade pipe for earth protection from earth point to earth plate surrounded by 150mm thick alternate layers of charcoal dust mix all with 35% common salt, 20mm bore medium grade GI Pipe for watering PCC pit type 1:3:6 type C-1 using 20mm graded stone aggregate, with RCC 550mm thick cover in 1:2:4 TYPE B-1 reinforced with 8mm dia CTD bars @8mm e/c both way. GI check nut, funnel with wire mesh necessary excavation and earth work in any type of soil all as specified and shown in electrical plate No 3 of MES SSR Part I 2009 complete all as specifed and directed.
M&L excavation over area n.exc. 1.50m deep and getting out in soft/loose soil complete all as speicified and directed.
-ditto- all as per item No 10.00 above but depth exc 1.5m but n.exc. 3.00m complete all as speicified and directed.
M&L surface excavation n.ex(not exceeding) 30 cmdeep and averaging 15cm deep and getting out complete all as specified and directed.
M&L for Reinforced cement concrete Nominal mix Type B-1 1:2:4 (20mm graded aggregate)in Foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs,under-reamed piles and mass concrete complete all as specified and directed.
M&L for Reinforced cement concrete Nominal mix Type B-1 1:2:4 (20mm graded aggregate)in Columns, pillars, piers, posts and struts complete all as specified and directed.
M&L for old size brick work with sub-class `B' bricks, straight or curved on plan exceeding 6 M mean radius built in cement mortar 1:6 complete all as specified and as directed.
M&L Brick work with sub-class `B' brick straight or curved on plan to any radius in half brick thick walls built in CM 1:4 complete all as specified and as directed.
M&L for old size brickwork with sub class ‘B’ bricks in one brick thick honey comb walling, built in cement mortar 1:6 complete all as speicified and directed.
M&L rendering 15 mm thick on other than fair faces of walls of brick work or concrete surfaces in cement mortar 1:6 compound finished fair and even complete all as specified and as directed.
M&L rendering 15 mm thick on fair faces of walls of brick work or concrete surfaces in cement mortar 1:4 with mixing of water proofing compound finished fair and smooth complete all as specified and as directed. Note: water proofing compound shall be measured seprately.
M&L TMT steel bars 10 mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as speicified and directed.
Ditto as per item 20.00 but 5 mm dia and over up to and including 10 mm dia in stirrups, spacers and binders complete all as speicified and directed.
M&L hardcore broken stones or boulders of gauge n exc. 63 mm, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rammed to a true surface complete all as speicified and directed.
M&L for 75mm thick cement concrete type D-2, 1:4:8 mix (using 40mm graded stone aggregates) as in bub base of flooring complete all as speicified and directed.
M&L for Non-skid coloured designer Pattern ceramic tiles 7 to 8 mm thick (square/rectanglar) area of each tiles exceeding 0.11 but n exc 0.18 sqm, in each floors etc, set and jointed in neat cement slurry and pointed in white or coloured cement to match over 15mm thick screed bed in CM 1:6 complete all as specified and as directed.
M&L for coloured glazed ceramic tiles (designer Pattern) in vertical surface 300 x 200 x 7 mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match tiles including 10 mm thick rendering in CM 1:4 on brick wall complete all as specified and as directed .
M&L for 50 mm thick PCC 1:3:6 type C-1 using 20 mm graded stone aggregate as in plinth protection laid in bays not exc 1.5m with expansion joints 30x10mm filled with mixture of hot bitumen and sand, finished the surface even and smooth without using extra cement complete all as specified and directed
S&F stop valves/angle valve, cast copper alloy, screwed down, high pressure with crutch or butter fly handles, screwed both ends for iron pipe 20mm dia, fixed complete all as specified and directed.
S&F 20 mm bore tubes medium grade galvanised with all fittings and fixed to walls, ceilings or laid in floors complete all as specified and directed.
S&F 15 mm bore tubes medium grade galvanised with all fittings and fixed to walls, ceilings or laid in floors complete all as specified and directed.
Supply only liquid water proofing compound complete all as speicified and directed.
Supplied and fixed vitreous china WHB white flat back size 550x400mm including Supplied and fixed angle iron brackets, waste coupling, complete all as specified & directed.
S&F 15 mm bore fancy type Pillar taps, cast copper alloy, with capstan heads, chromium plated, screwed down high pressure, with or without lettered 'Hot' or 'Cold' with long screwed shanks and fly-nuts, screwed for iron pipe and fixed complete all as specified and as directed.
S&F PVC connections of 15mm size with PTMT nuts of 450 mm long complete all as specified and directed.
S&F 15 mm bore Bib taps, cast copper alloy with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule and fixed complete all as specified and as directed.
S&F Towel Rail 600mm long of PTMT fixed with and including Chromium plated brass screws and wooden/plastic cleats. (Minimum weight 190gms) complete all as specified and directed.
S & F for 75 mm bore PVC (SWR) bends of any radius complete all as specified and directed.
S&F framed work as in Roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc confirming Fe 410 gde E250 fixed complete all as specified and as directed.
S&F prepainted galvolum aluminium zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall ridges, fixed with self tapping screws complete all as speicified and directed.
M&L for preparation of New or previously untreated steel surfaces of any description, not otherwise described, over 10 cm width or girth and applying two coats of Synthetic enamel paint (Ordinary tint) over a coat of red oxide. etc. complete all as specified and directed.
M&L for Chequered cement concrete tiles 20cm x 20cm x 25mm thick, set, jointed and pointed in neat cement slurry in floors with grey pigment cement and pigments ncluding 15mm thick screed bed or bedding layer of cment mortar (1:6) complete all as specified and directed.
M&L for PCC 1:3:6 type C-2 using 40mm graded stone aggregate for surface channels, bed of drains incl forms/moulds etc complete all as speicified and directed.
M&L forming fair finished drain or channel 30 cm innner girth in cement concrete unsing extra cement including forms, moulds mitred/stopped ends etc complete all as speicified and directed.
S&F joist, channel, angle or tee sections fixed independently without connecting plates etc cut to ordinary length and fixed as per directions Fe 410 W Gde complete all as speicified and directed.
M&L for Excavating in post holes (or similar holes) each n exc 0.5 cu. m, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm complete all as speicified and directed.
S&F Rotational moulded polye?thylene water storage tanks 2000 Ltr(cylindrical vertical with closed top) hoisted and fixed in position including 20mm Ball brass valves, high pressure, with polythene float and flynut complete, screwed for iron pipe or brass ferrule and fixed complete all as speicified and directed.
S&F PVC (SWR) pipes 110mm single socketed, in any length with rubber ring joints, laid in trenches or in floors complete all as specified and directed.
M&L for formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batten complete all as specified and directed.
M&L for formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick (Horizontal or sloping complete all as specified and directed.
M&L for formwork to sides of pillars, posts, struts, piers, columns and stanchions complete all as specified and directed.
S&F 75mm PVC (SWR) floor trap, plain with grating including pointing with solvent cement complete all as specified and directed.
S&F Plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, without any attachment complete all as specified and directed.
M&L for PCC (1:4:8) type D2 using stone aggregate as in foundation complete all as speicified and directed.
M&L for preparation of plastered surfaces of any description and applying two coats of cement based paint over a coat of cement primer (Self primer) complete all as speicified and directed.
BRITE INDUSTRIES
M/s M.S. Electric Co.
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .