Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹12.5 LAccepted-AOC | L1 | Accepted-AOC Being L-1 | |
| 2 | L2₹13.9 L+₹67,778 (5.14%)Rejected-Finance | L2 | Rejected-Finance Being L-2 | |
| 3 | L3₹13.9 L+₹72,548 (5.51%)Rejected-Finance GURU NANAK NAGAR GALI BHATIA DHARAMSHALA WALI SIRSA HARYANA PIN 125055 | SIRSA | HARYANA | 125055 | L3 | Rejected-Finance Being L-3 | |
| 4 | L4₹13.9 L+₹76,613 (5.81%)Rejected-Finance H NO 29 DEVILAL COLONY TCP 2 HISAR CANTT HARYANA | HISAR | HISAR | HARYANA | 125006 | L4 | Rejected-Finance Being L-4 | |
| 5 | L5₹14.2 L+₹1.0 L (7.93%)Rejected-Finance | L5 | Rejected-Finance Being L-5 |
Tender Value
₹25 L
EMD Value
₹50,000
Closing Date
27 Jun 2025, 6:00 pmClosed
GE Hisar
GE Hisar
REPAIRS / REPLACEMENT OF MCBS, DBS, SUBMAIN WIRING AND OTHER CONNECTED WORKS IN OTM ACCN UNDER GE HISAR AT HISAR MIL STN
2025_MES_710901_1
GE(H)-14/2025-26
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
Hisar
Please refer Tender documents.
6 documents required · 6 mandatory
₹500
GE Hisar
₹50,000
Yes
5 Aug 2025
28 May 2025
5 Jul 2025
28 May 2025
27 Jun 2025
12 Jun 2025
Amount
S&F sheet metal enclosure distribution board VTPN, 4 way, double door powder coated, protection class IP-54, isolated neutral bar, mechanical impact strength IK 09 suitable for mounting MCB / MCCB DBs confirming to IS-13032, IS-8632, BS 5484 with min 200 Amp rating copper bus bar and grouting, fixing on wall with nut, bolts washers proper with PCC works complete all as specified and as directed by Engineer-in-Charge.
S&F in replacement factory made powder coated distribution board SPN, 8 ways, IS 8623, IEC 61439-3, double door, protection class IP-43, fabricated from CRCA sheet and fixed / flushed on wall suitable for universal mounting including 100 Amps bus bar, neutral bus bar, standard DIN rail, earth bar and cable ties for cable management, top and bottom removable glands plates with knockouts and suitable for one DP MCB as incomer and outgoing MCBs as required at site alongwith blanks including cutting of wall if required and making good disturbed surface in CM (1:3) and finishing the surface to match with existing surface etc complete all as specified and directed. Note :- (i) MCBs shall be measured and paid seperately. (ii) All cables terminating into MCBs shall be connected by using suitable copper lugs/thimbles/sleeves and its cost shall be deemed to be included in the quoted rates. Make : Legrand/C&S/Indoasian/Havells/Hager
S&F in replacement factory made powder coated distribution board SPN, 4 ways, IS 8623, IEC 61439-3, double door, protection class IP-43, fabricated from CRCA sheet and fixed / flushed on wall suitable for universal mounting including 100 Amps bus bar, neutral bus bar, standard DIN rail, earth bar and cable ties for cable management, top and bottom removable glands plates with knockouts and suitable for one DP MCB as incomer and outgoing MCBs as required at site alongwith blanks including cutting of wall if required and making good disturbed surface in CM (1:3) and finishing the surface to match with existing surface etc complete all as specified and directed. Note :- (i) MCBs shall be measured and paid seperately. (ii) All cables terminating into MCBs shall be connected by using suitable copper lugs/thimbles/sleeves and its cost shall be deemed to be included in the quoted rates. Make : Legrand/C&S/Indoasian/Havells/Hager
S&F in replacement factory made powder coated distribution board SPN, 12 ways, IS 8623, IEC 61439-3, double door, protection class IP-43, fabricated from CRCA sheet and fixed / flushed on wall suitable for universal mounting including 100 Amps bus bar, neutral bus bar, standard DIN rail, earth bar and cable ties for cable management, top and bottom removable glands plates with knockouts and suitable for one DP MCB as incomer and outgoing MCBs as required at site alongwith blanks including cutting of wall if required and making good disturbed surface in CM (1:3) and finishing the surface to match with existing surface etc complete all as specified and directed. Note :- (i) MCBs shall be measured and paid seperately. (ii) All cables terminating into MCBs shall be connected by using suitable copper lugs/thimbles/sleeves and its cost shall be deemed to be included in the quoted rates. Make : Legrand/C&S/Indoasian/Havells/Hager
S&F in replacement factory made powder coated distribution board TPN, 4 ways, IS 8623, IEC 61439-3, double door, protection class IP-43, fabricated from CRCA sheet and fixed / flushed on wall suitable for universal mounting including 200 Amps bus bar, neutral bus bar, standard DIN rail, earth bar and cable ties for cable management, top and bottom removable glands plates with knockouts and suitable for one DP MCB as incomer and outgoing MCBs as required at site alongwith blanks including cutting of wall if required and making good disturbed surface in CM (1:3) and finishing the surface to match with existing surface etc complete all as specified and directed. Note :- (i) MCBs shall be measured and paid seperately. (ii) All cables terminating into MCBs shall be connected by using suitable copper lugs/thimbles/sleeves and its cost shall be deemed to be included in the quoted rates. Make : Legrand/C&S/Indoasian/Havells/Hager
S&F in replacement 4 pole MCCB, 63 Amps 415 Volts , type 'C' curve, 50HZ, 10 KA, with rupturing cap 16 KA fixing in DB complete all as specified & directed. Note :-Make of MCB shall be same of that DB.
S&F in replacement 4 pole MCCB, 100 Amps 415 Volts , type 'C' curve, 50HZ, 10 KA, with rupturing cap 16 KA fixing in DB complete all as specified & directed. Note :-Make of MCB shall be same of that DB.
S&F in repair of 4 pole MCCB 160 Amp, 10KA, 'C' curve,50 Hz, 415 V with rupturing capacity 16 KA complete all as specified and directed.
S&F in replacement MCB SPN, 40 to 63 Amps 240 Volts , type 'C' curve, 10 KA, IS-8828 marked fixing in DB complete all as specified & directed. Note :-Make of MCB shall be same of that DB.
S&F in replacement MCB SP, 6 to 32 Amps 240 Volts , type 'C' curve, 10 KA, IS-8828 marked fixing in DB complete all as specified & directed. Note :-Make of MCB shall be same of that DB
S&F in replacement 4 pole,MCB TPN 40-100 Amps 415 Volts , type 'C' curve, 10 KA, with rupturing cap 16 KA fixing in DB complete all as specified & directed. Note :-Make of MCB shall be same of that DB
S&F Sub main wiring with two single core cable PVC insulated unsheathed of copper multi stranded conductor FRLS cable of size 6.00 sqmm, 1100 votls grade drawing through and EXISTING concealed conduit 25 mm dia medium duty including acessories such as Tee, bend, Elbow etc, ISI marked with and including PVC insulated 6.00 sqmm unsheathed multistranded FRLS copper conductor cable for earth continuity and connected to common earth dolly including cutting chasing of wall, if required and making good disturbed surface in CM (1:3) and finishig the surface to match with existing surface, etc complete all as specified and directed including taking down old unserviceable submain wiring. Note:- Two lengths of 6.00 Sqmm cable, one length of 6.00 Sqmm cable and one length of PVC conduit will be measured as one length.
S&F Sub main wiring with two single core cable PVC insulated unsheathed of copper multi stranded conductor FRLS cable of size 4.00 sqmm, 1100 votls grade drawing through and EXISTING concealed conduit 25 mm dia medium duty including acessories such as Tee, bend, Elbow etc, ISI marked with and including PVC insulated 4.00 sqmm unsheathed multistranded FRLS copper conductor cable for earth continuity and connected to common earth dolly including cutting chasing of wall, if required and making good disturbed surface in CM (1:3) and finishig the surface to match with existing surface, etc complete all as specified and directed including taking down old unserviceable submain wiring. Note:- Two lengths of 4.00 Sqmm cable, one length of 4.00 Sqmm cable and one length of PVC conduit will be measured as one length.
S&F Sub main wiring with two single core cable PVC insulated unsheathed of copper multi stranded conductor FRLS cable of size 2.5 sqmm, 1100 votls grade drawing through and EXISTING concealed conduit 25 mm dia medium duty including acessories such as Tee, bend, Elbow etc, ISI marked with and including PVC insulated 2.5 sqmm unsheathed multistranded FRLS copper conductor cable for earth continuity and connected to common earth dolly including cutting chasing of wall, if required and making good disturbed surface in CM (1:3) and finishig the surface to match with existing surface, etc complete all as specified and directed by including taking down old unserviceable submain wiring. Note:- Two lengths of 2.5 Sqmm cable, one length of 2.5 Sqmm cable and one length of PVC conduit will be measured as one length.
M&L in repair of sub main wiring using two single core 1.5 Sqmm FRLS PVC insulated and unsheathed cable with copper conductor 1100 volts grade ISI marked drawing in pvc conduit/EXISTING concealed walls/ceiling with accessories like bends, tee, etc. Dismantling and fix on wall and ceiling and connecting to earth dolly and including 1.5 Sqmm earth wire, PVC insulated & unsheathed all as directed.
S&F in replacement single core 2.5 sqmm flexible cable PVC insulated FRLS unsheathed cable with copper conductor 1100 volts grade confirming to IS-694 complete all as specified and directed.
S&F in replacement two core 1.5 sqmm flexible cable PVC insulated FRLS unsheathed cable with copper conductor 1100 volts grade confirming to IS-694 complete all as specified and directed.
S&F in replacement twin core flat 10 Sqmm size 1100 volt grade heavy duty cable PVC insulated with aluminum multistranded conductor PVC sheathed for service connection complete all as specified and directed.
S&F in replacement twin core flat 16 Sqmm size 1100 volt grade heavy duty cable PVC insulated with aluminum multistranded conductor PVC sheathed for service connection complete all as specified and directed.
S&F in replacement rigid non-metallic PVC conduit 20mm dia including fixing on pole/wall with fittings like Tees, bends, elbows, reducer, bell mouth etc and fixing accessories such as coupler lock, nuts, saddles, pipe hooks etc complete all as specified & directed.
S&F in replacement PVC casing and caping of 20mm width all as specified and directed.
M&L for earthing complete with galvanized steel earth plate electrode 60cmx60cmx6mm thick burried directly in ground (earth pit not less than 2.25 m deep below ground level) with top edge of plate not less than 1.5 m deep below normal ground level and connected to and including galvanized iron earth wire 4 mm dia by means of GI nuts, bolts, check nuts, washers thimbles, etc as shown in electrical plate No 3 of SSR Part-I and connection to main switch board/Test point/panel/equipment and testing on completion including excavation and earth work in any type of soil, returning filling in, and removal of surplus spoil to a distance not exc 50 metre, charcoal and salt in alternate layer 15 cm thick all around the earth plate electrode, MS funnel with wire mesh, GI pipe medium grade 20 mm bore for watering and 15 mm bore upto 7.50 metre long GI pipe light grade for earth wire protection fixed with poles/wall with two clamps, made from MS flat 25 mmx3mm, bolts, nuts and washers, PCC chamber (1:3:6) type C1, 40mm thick precast RCC cover 1:2:4 type B1 shall be provided on CI frame etc complete all as specified & as directed including dismantling & taking out old existing unserviceable earthing. Note :- PCC chamber shall be constructed at least 1.5m away from the earth electrode and pipe for watering shall be provided in slanting manners.
Taking out the old unserviceable LT underground cable upto 25 sqmm 1100 volts grade, XLPE insulated and PVC sheathed, armoured heavy duty with multistrand aluminium conductors from trenches/wall/floor/road/ culverts or pole etc complete all as specified and directed . Note : Excavation and earth work, duct work, GI pipe for laying of cable and sand cushing/cable protection covers etc are beyond the scope of this item and shall be measured & paid for separately under relevant items of BoQ.
Supply, laying, testing and commissioning XLPE insulated armoured heavy duty electric cable of size 16 sqmm 2 core with aluminium conductor cable 1100 volts grade in trenches ducts, pipe on walls, poles including taking down old UNSV Cable complete all as specified and directed.
Supply , laying , jointing, testing and commissioning of size 10 sqmm 2 core LT underground cable , 1100 volts grade, XLPE insulated and PVC sheathed, armoured heavy duty with multistrand aluminium conductors IS-7098, laid in trenches /fixed on wall /floor /road /culverts /pole or encased in GI pipe complete including taking out existing u/s LT cable all as specified. Note : Sand cushioning, cable protection, GI protection pipe, clamps, jointing kits and excavation & earth work shall be measured & paid for separately.
Supply , laying , jointing, testing and commissioning of size 16 sqmm 4 core LT underground cable , 1100 volts grade, XLPE insulated and PVC sheathed, armoured heavy duty with multistrand aluminium conductors IS-7098, laid in trenches /fixed on wall /floor /road /culverts /pole or encased in GI pipe complete including taking out existing u/s LT cable all as specified. Note : Sand cushioning, cable protection, GI protection pipe, clamps, jointing kits and excavation & earth work shall be measured & paid for separately.
Supply and fixing LED flood light 100 watt 230 V AC outdoor type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant complete with driver and lamp.
Excavation in trenches not exceeding 1.5 m wide and not exc. 1.5 m depth for laying cables, foundation for pole etc and getting out in soft/loose soil complete all as specified and as directed.
Supply and laying double wall corrugated pipe(DWC) confirming to IS 19430 Part -I of size 50mm outer dia and 38mm inner dia complete all as specified and as directed
fauji electric works (BID ID -3330698)
BHATIA ENTERPRISES (BID ID -3329836)
M/s Devendera construction (BID ID -3329869)
M/S KAVITA CONSTRUCTION (BID ID -3330797)
M/s Rao Constructions, 1173 Urban Estate-II, Hisar (BID ID -3330886)
Natwadia Electrical Company (BID ID -3330802)
R N Enterprises (BID ID -3336593)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .