GE AF TUGHLAKABAD
GE AF TUGHLAKABAD SANGAM VIHAR PO NEW DELHI 110080
Repair to Column, Beam, Chajja, Plastering and connected Work 12 BRD AF Stn Najafgarh under GE(AF) Tughlakabad
2020_MES_381012_1
GE/TKD/TOKEN-65/2020-21
Open Tender
Civil Works - Others
Item Rate
330 days
GE AF TUGHLAKABAD
MES contractor enlisted as Class D or above category ai having deposited Standing Security of Rs. 100000 with dept. Contractors not enlisted in MES should meet the MES enlistment criteria corresponding to appropriate class and category
8 documents required · 8 mandatory
₹500
Yes
GE AF TUGHLAKABAD
₹60,000
Yes
15 Mar 2021
25 Sept 2020
24 Oct 2020
5 Oct 2020
22 Oct 2020
5 Oct 2020
26 Sept 2020 - 5 Oct 2020
60 days
Amount
Chipping loose/carbonated/ disintegrated concrete upto reinforced bars and cleaning of existing concrete surface of columns, beams, slabs, waste slabs etc. carefully by chiseling or sand blasting without damaging the existing concrete and using power driven hammer (Hilti-TE 504 or equivalent)/ pneumatic chisel of standard and by wire brush (metallic brushes only), tapering of all edges, making square shoulders of cavities including the all necessary machinery, compressor, coarse sand, cleaning the surfaces by air jet, disposal of unserviceable materials etc. inclusive of all labour, materials, equipment etc. complete including the cost of scaffolding where ever required as per specifications and direction of Engr-in-charge complete all as specified and directed by the Engr-in-charge. NOTES: (i) The work for strengthening of structure from BOQ sk item No 1 to 20 shall be executed by authorised manufacturer and applicator. (ii) Existing reinforcement in all concrete surfaces shall be thoroughly scrubbed with brushes, washed with water and allowed to dry. (ii) Work has to be carried out in patches area shall not exceeding 2.00 Sqm in each patch. (iii) Concrete surface area of the structural members shall be measured for payment purpose except work covered under BOQ sl item No 3 & 4 here in after. (iv) Average thickness of the patch work 50mm. (v) Cost of scaffolding deemed to be included in quoted rates.
Providing and fixing shear connectors of 8mm dia, HYSD steel with after applying two components, styrene & cement free, epoxy-acrylate fixing and anchoring compound supplied in self mixing cylinder in cartridge form that avoids site mixing using standard sealant applicator gun after drilling holes of 10mm diameter to a minimum depth of 100mm and maximum depth of 200 mm at required locations, inclusive of all material, manpower and equipment complete all as specified and directed by Engr-in-charge.
Applying two coats alkaline rust converting remover of approved quality sika rust off 100, rust klean, rust remover confirming to ASTM-B-117 after cleaning the existing reinforcement with wire / rotary wiry brush, making the surfaces free from loose material, dirt etc. complete on the rebars including cleaning the reinforcement wire brushing to remove loose rust spall, with time interval of 1 hours between the coats complete and thoroughly washing with water allowing it to dry all complete as per direction Engineer In charge.
Providing and applying anticorrosive treatment by paint brush to the exposed structural reinforcement by two coats of anti-corrosive epoxy based, Zn rich epoxy phenolic material of approved anticorrosive product with time interval of minimum 4 hours between each coat all complete as per direction of Engr in charge. Make of anticorrosive material shall be: BASF/STP/ SIKA/Fosroc/Krishna Conchem
Providing and applying a single coat of two component solvent less epoxy resin based bonding coat between the old and new concrete surface complying to ASTM C881 Type-2, Grade-2 and class B&C having a open time of its adhesive bond strength using brush or roller before the application of repairing material including the cost labour, material, T&P and equipment etc. all complete as per direction of Engr-in-Charge.
M&L for Polymer Modified Mortar for Cracked & Spelled Portions: Building up the profile of structural members 10/25/50 mm average depth by using emulsified SBR latex having solid content not less than 40% and conforming to ASTM C-1059 Type-I/Type-II in damaged areas (1 Cement+2 coarse sand+ 1part stone aggregate 10mm down size + 20 % latex by weight of cement) with 0.35 w/c ratio, in maximum 10 - 15 mm thick layers wise by providing SBR bond coat in between successive layers, including leveling profiling complete. Proper moist curing to be done for the repair work average 50mm thickness polymer modified mortar shall be applied complete all as specified and directed by Engineer-in-Charge.
M&L for 15 mm cement plaster on rough surfaces of single mix 1:4 (1 cement: 4 coarse sand) without using extra cement complete all as specified and directed by Engineer-in-Charge.
S&F Non Return Valve with nozzle including drilling hole by power drill machine for press pumping through machine to injecting to cracked RCC slab/Column/beam upto bonding of surface and similar work etc at site complete all as specified and directed by Engr-in-Charge.
M&L for applying epoxy through using low press injection of an epoxy or polyurethane materials to coating/filling porosity of concrete structure to RCC surface by using 1.5 ltrs per Sqm form a layer/film to steel and concrete to protect structure from environment effect etc complete all as specified and directed by Engr-in-Charge.
S&F welded wire mesh on column and beam exceeding 4 Kg per Sqm of weight complete all as specified and directed by Engr-in-Charge.
Taking down cement plaster on brick or stone walls, etc., including raking out joints, hacking for key, scrubbing down with water, etc., complete all as specified and directed by Engineer-in-Charge.
M&L rendering 15mm thick on brick walls or on concrete surfaces in cement mortar 1:6 surfaces finished even and smooth without using extra cement, complete all as specified and directed by Engr-in-charge.
M&L for rendering 15 mm thick in cement mortar 1:4 on fair faces of brick work or concrete surfaces like parapets, chajjas, projections, facia etc finished even and smooth without using extra cement including necessary scaffolding if required, complete all as specified and directed by Engr-in-charge.
M&L rendering 5mm thick to soffit of RCC slabs (Ceiling) in cement mortar 1:4 surfaces finished even and smooth without using extra cement including necessary scaffolding if required, complete all as specified and directed by Engr-in-charge.
M&L for preparing of new plastered surfaces and applying Two coats of cement base paint on surfaces of walls over a coat of primer complete all as specified and directed by Engr-in-charge.
M&L for preparation of new decorated surfaces of ceiling and applying three coat of white wash including necessary scaffolding complete all as specified and as directed by Engr-in-Charge.
Roughening surfaces of old concrete on roof & parapet wall by picking scraping, sweeping, cleaning and washing down with water and cleaned off all foreign matters and dust etc. complete all as specified and directed by Engineer-in-Charge.
M&L for 15mm thick cement plaster in cement mortar 1:6 with a mixture of water proofing compound @ 3 % by weight of cement on dried mortar surface finished fair and even without using extra cement, complete all as specified and directed by Engineer-in-Charge. Note :- Water Proofing Compound shall be measured and paid under respective item separately
Supply only liquid water proofing compound complete all as specified and directed by Engineer-in-Charge.
M&L for cleaning the roof surface thoroughly with wire brush, washed, dried up and cleaned of all foreign matter and dust to receive primer and apply one coat of approved bitumen primer at the rate of 0.25 to 0.30 ltrs per Sqm on the dried surface, on this primed surface the polymerized modified bituminous water proofing memberance with non woven polyester as reinforcement membrane with white gravel /mineral finished on upper side having weight at the rate of 3 Kg per Sqm & minimum thickness 3mm shall be laid by torch application method. The overlap while torching shall be 100mm on length side & 150 mm on width side of membranes as per manufacture instructions and as directed by Engr-in-charge.
Dismantling floor hearth or wall tiling including cement mortar bedding (but not backing) removing serviceable tiles to store & rubbish off the premises, complete all as specified and directed by Engineer-in-Charge.
Demolition of un-reinforced cement concrete in ground floors and pavings not exceeding 15 cement mortar thickness, complete all as specified and directed by Engineer-in-Charge.
M&L for 100mm thick cement concrete 1:2:4 type-B2 by using 40mm graded stone aggregate as in path/plinth protection finishing cement concrete surface even and smooth without using extra cement complete all as specified and directed by Engineer-in-Charge.
M&L for cement concrete chequered tiles 20cmx20cmx20mm thick set, jointed & pointed in neat cement slurry with grey cement and pigments including and over 15mm thick screed bed in cement mortar complete all as specified and directed by Engineer-in-Charge.
M&L for Glazed ceramic tiles in vertical surface of size 350x250x7 mm/450x350x7 mm thick set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of the tile and including 15mm thick rendering in cement mortar 1:4 complete all as specified and directed by Engineer-in-Charge.
M&L for Vitrified Ceramic tiles dark shade 10mm thick (square/ rectangular) polished, area of each tiles not exceeding 0.36 Sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of the tiles, laid on floor, over and including 15mm thick screed bed in cement mortar 1:6 complete all as specified and directed by Engineer-in-Charge.
M&L for PCC 1:3:6 type C1 by using 20mm graded stone aggregate providing kerbs or stop rounded or chamfered on edges complete all as specified and directed by Engineer-in-Charge.
Demolition of brick work or stone/ boulder masonry, built in cement mortar including all quoins, pillars etc. excluding ashlar facing, dressed stonework and precast concrete articles complete all as specified and directed by Engineer-in-Charge.
M&L brick work with sub class ‘B’ bricks, straight or curved on plan exceeding 6m mean radius built in cement mortar 1:6 and external face of brick pointed flush in the same mortar complete all as specified and directed by Engr-in-Charge.
Dismantling of existing mild steel work and S&F mild steel framed work such as grills, gratings, gates etc. with ends of bars shouldered and/or riveted or forged into spikes, framed guard bars, barred iron doors, ladders, framed balusters, walk ways, railings, framework of water tanks and similar work conforming to Fe.290.Gde-E-165 complete all as specified and as directed by Engr-in-Charge.
Note for item No 1 to 30: The quoted rates deemed to be included the cost of removing of demolished or building malba and rubbish material out of MoD land and depositing where directed at a level not exceeding 1.5 mtr above the starting point.
Note for schedule of credit: The amount of Rs 5,600.00 against schedule of credit given on Tender Serial Page No 30 shall be deducted from the total amount quoted by the contractor against BOQ while deriving the contract sum for acceptance.
Skyline Encon
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .