| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹44.8 LAccepted-AOC | L1 | Accepted-AOC AOC | |
| 2 | L2₹46.8 L+₹2.0 L (4.50%)Rejected-Finance C O GENERAL DAIRY VILLAGE BARAGAON SRI GANGANAGAR 335 001 | GANGANAGAR | RAJASTHAN | 335001 | L2 | Rejected-Finance Not the lowest tenderer | |
| 3 | L3₹47.5 L+₹2.7 L (6.02%)Rejected-Finance | L3 | Rejected-Finance Not the lowest tenderer | |
| 4 | L4₹51.2 L+₹6.4 L (14.3%)Rejected-Finance | L4 | Rejected-Finance Not the lowest tenderer | |
| 5 | L5₹56.7 L+₹11.9 L (26.6%)Rejected-Finance 110059 NEW DELHI NATIONAL CAPITAL TERRITORY OF DELHI 110059 | WEST DELHI | DELHI | 110059 | L5 | Rejected-Finance Not the lowest tenderer |
Tender Value
₹48.3 L
EMD Value
₹96,500
Closing Date
17 May 2025, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
HQ CWE SRI GANGANAGAR
HQ CWE POST BOX 48 SRI GANGANAGAR-335001 (Rajasthan)
PROVN OF WALKING PLAZA AND GREEN/ LUNG SPACE AT MIL STN ABOHAR
2025_MES_703053_2
CA NO CWE SGNR T-104 OF 2024-25
Open Tender
Civil Works
Item Rate
180 days
GE ABOHAR
As per NIT
9 documents required · 9 mandatory
₹500
Yes
GE ABOHAR
₹96,500
Yes
23 Jun 2025
28 Apr 2025
19 May 2025
28 Apr 2025
17 May 2025
5 May 2025
Amount
Surface dressing n.exc 15cm deep and getting out in soft/ loose soil complete all as specified and directed.
Removing excavated material (soils) exc 250m and n.exc 500m and depositing where directed at a level not exc 1.5 m above the starting point complete all as specified and directed.
Excavation in trenches n.exc. 1.5m wide and n.exc 1.50 m in depth for laying cable; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n.exc. 10 Sqm on plan and getting out in getting out in soft / loose soil complete all as specified and directed by Engineer-in-Charge.
Excavating over areas in soft/loose soil exc 1.5 mtr and not exc 3 mtr in depth and getting out complete all as specified and directed.
M&L for PCC (1:4:8), type D2, using 40mm graded stone aggregate as in foundation, filling & mass concrete complete all as specified and directed by Engineer-in-Charge.
M&L for formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter rough finish surface of concrete flat complete all as specified and directed by Engineer-in-Charge.
M&L for formwork to sides of pillars, columns etc; rough finish surface of concrete square, rectangular or polygonal complete all as specified and directed by Engineer-in-Charge.
M&L for formwork to sides and soffits of floor or roof beams, beam hunchings, girders, bressummers, lintels, cantilevers, etc. also splays between floors and beams, etc. rough finish surface of concrete flat complete all as specified and directed by Engineer-in-Charge.
M&L for formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work not exc 200 mm thick (horizontal or sloping) rough finish surface of concrete flat complete all as specified and as directed by Engineer-in-Charge.
M&L for fromwork to edges of concrete flats, treads breaks in floors, window cills, concrete railings, openings in convert valley floor and roof exc 5cm but n.exc 10 cm wide and sides of RCC/PCC bands in walls complete all as specified and directed by Engineer-in-Charge.
M&L for TMT bars 10 mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed by Engineer-in-Charge.
All as per Ser item No 11.00 above but 5mm dia and over upto and including 10mm dia as in stirrups, spaces & binders complete all as specified and directed by Engineer-in-Charge.
M&L for reinforced cement concrete (design mix) M-25 using 20mm graded stone aggregrate as in foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, pillers etc complete all as specified and directed by Engineer-in-Charge. Note : Reinforcement shall be measured and paid seperately under respective item of BoQ.
M&L for reinforced cement concrete (design mix) M-25 using 20mm graded stone aggregrate in columns, pillars complete all as specified and directed by Engineer-in-Charge. Note : Reinforcement shall be measured and paid seperately under respective item of BoQ.
M&L for reinforced cement concrete (design mix) M-25, using 20mm graded stone aggregrate in beams, cantilevers, bressummers, lintels over 1.5m span complete all as specified and directed by Engineer-in-Charge. Note : Reinforcement shall be measured and paid seperately under respective item of BoQ.
M&L for reinforced cement concrete (design mix) M-25, using 20mm graded stone aggregrate in slab supported on walls, beams ans columns in floor, roofs, landings balconies, deck slabs and in shelves and the like complete all as specified and directed by Engineer-in-Charge.. Note : Reinforcement shall be measured and paid seperately under respectively item of BoQ.
Returning, filling in, including spreading levelling including watering & well ramming in layers n.exc 25 cm all in soil complete all as specified and as directed by Engineer-in-Charge.
Spreading and levelling in layers n.exc 25cm thick and well ramming including watering as required under floors; all as directed. (in floor with available earth from excavation as approved by Engr-in-Charge).
Removing excavated materials n.exc 50 m and depositing where directed at a level n.exc 1.5 m above the starting point complete all as specified and as directed by Engineer-in-Charge.
M&L for hardcore of gauge n exc. 63mm, deposited, spread and levelled in layers n exc.15cm thick, watered and rolled/ rammed to a true surface in broken stone or boulders (15cm compacted thickness) complete all as specified and directed by Engineer-in-Charge.
M&L for 75 mm thick, PCC (1:3:6), type C-1, using 20 mm graded crushed stone aggregate as in plinth protection finished even and smooth without using extra cement with & including 10 mm wide, 30 mm deep joints at the rate of 3.00 mtr centre to centre and at every turning & filling the joints with bitumen & sand mixture complete all as specified and directed by Engineer-in-Charge.
M&L for 100 mm thick PCC (1:4:8), type D2, using 40mm graded stone aggregate as in sub base below floors complete all as specified and directed by Engineer-in-Charge.
M&L for 5 mm thick rendering in cement mortar (1:4) (as second coat), over and including 10 mm thick rendering in cement mortar (1:6) (as first coat) of fair faces of brick work or concrete surfaces of wall, incl mixing only liquid water proofing compound in second layer only as per manufactures instruction, finished the surface even and smooth without using extra cement complete all as specified and as directed by Engineer-in-Charge. Note :- WPC Shall be measured and paid separately as supply only.
M&L for rendering, 5 mm thick on brick work or concrete surfaces in cement mortar (1:3) on ceiling finished even and smooth without using extra cement complete all as specified and directed by Engineer-in-Charge.
Supply only liquid water proofing compound all as specified and directed by Engr-in-Charge.
M & L for Preparation of newly plastered surfaces and applying two coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, alkali & fungal resistance,dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces over and after applying wall care putty in two coats on wall surface and smoothening the surfcae with sand papers by Mechanical method (hand electric grinder) prepatory to paint all as directed and specified.
M&L for preparation and applying three coats of white wash on newly plastered surfaces of ceiling complete all as sepecified and directed by Engineer-in-Charge.
M&L for machine cut Kota stone slab flooring 18-20mm thick (size 550 x 550 mm) over and including 15mm thick screed bed in CM (1:6) laid and and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete all as specified and directed by Engineer-in-Charge.
M & L Machine cut kota stone slab 18-20mm thick in riser of steps in single piece, skirting, dado and pillar over cement screed base laid over and including 10 mm thick screed bed in cement mortar 1:4 set and jointed with grey cement slurry mixed with pigment to match of the slab including rubbing and polishing, complete all as specified and directed by Engineer-in-Charge.
M&L for brick work with fly ash bricks, of old size bricks, straight or curved exc. 6 m mean radius built in CM (1:6) complete all as specified and directed by Engineer-in-Charge.
M&L endura Non-skid Ceramic coloured/ printed tiles 7 to 8 mm thick square/ rectangular), area of each tiles exceeding 0.11 sqm but not exceeding 0.18 sqm, in floors etc. over and including 15 mm thick screed bedding in cement mortar (1:6), set and jointed in neat cement slurry and pointed in white or coloured cement to match the floor complete all as specified and as directed by Engineer-in-Charge.
Surface excavation in soft/loose soil n.exc (not exceeding) 30 cm deep and averaging 15cm deep and getting out complete all as specified and directed.
M&L for factory made precast PCC solid block (1:2:4), type B-1, using 20mm graded crushed stone aggregate as in kerb stones of size 300mm x 150mm x 300mm machine made set in cement and sand mortar 1:4 complete all as specified and directed by Engineer - in - Charge.
Providing and laying 60mm thick factory made chamfered edge cement concrete paver block of M-30 grade with approved colour, design & pattern as in footpath, parks, lowns, drive ways or light traffic parking etc, of required strength, thickness & size/shape made by table vibratory method using required colour & pattern over and including 50mm thick compacted bed of coarse sand, compacting and proper embedding/laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with fine sand and cutting of paver block as per required size and pattern, finishing, filling the joints with fine sand and sweeping extra sand complete all as specified and directed.
S&F garden bench of size 1500mm x 450mm x 600mm (seat height 330mm) of cast iron leg/ side support and powder coated mild steel seat and back minimum weight 70 Kg complete all as specified and directed.
S&F structural steel work in tubular trusses including special shaped washer etc complete using ERW or incuction butt welded tubes grade ST-240 complete all as specified and directed.
S&F exc 12mm dia and n.exc 20mm dia and exc 30mm long MS Screw bolt machine made with hexagonal or square head at one end and screwed end fixed with washer complete all as specified and directed.
S&F pre-painted galvalume cladding aluminium zinc coating GI based corrugated steel sheet 0.55mm thick of an colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall, foxed with self tapping screws complete all as specified and directed.
S&F pre-painted galvalume aluminium zinc coating GI based plain steel sheet 0.50mm of thick any colour having tensile strength 0f 550 Mpa as in roof covering/ cladding to wall, fixed with shelf tapping screws complete all as specified and directed.
Material and labour for concealed Point wiring for one light point/fan point /bell point controlled by one switch (using red, black and green colour wires as colour coding) complete with 1.5 Sqmm (nominal cross section area) single core FRLSH PVC insulated unsheathed and multi strand copper conductor cable 1100 volt (ISI marked) drawn through and including PVC conduit 20mm dia (medium duty, ISI marked) with all fittings and all accessories i.e. pipe bend, pipe hook, elbow, junction boxes, 3 mm thick bakelite sheet top cover (ISI Marked) fitted with Chromium plated brass screws & washers for piano type fittings and for 2 mm thick galvanised steel pressed sunken box suitable for switch socket (Min 60mm deep, suitable length) concealed in wall, including provn of 1.5 Sqmm single core FRLSH PVC insulated multi strand copper conductor wire continues as earth wire connected to earth dolly etc. including cutting chases in wall and making good disturbed surfaces of walls/ceiling/floors etc. by using CM (1:3) complete all as specified and as directed. Note : switches/ socket / regulator shall be measured and paid separately under appropriate item of BOQ.
All as per Ser item No 40.00 above but for One three pins 5 Amps socket outlet point on independent board with other switches.
All as per Ser item No 40.00 above but for One three pins 5 Amps socket outlet point on same board with other switches
S & F switch piano one way 5/6 amps 240 volts complete all as specified and directed.
S & F socket 5 in 1, 5 amps flush type complete all as specifeid.
M & L Ceiling rose, 3 terminals/phase type, fabricated of PVC/Polycarbonate, isolated body complete all as specified and directed.
Supplied and fixed Miniature circuit breaker (MCB) single pole, 240 Volts, of 6-32 amps current rating and 10 KA breaking capacity, B' series type complete all as directed by Engr-in-charge.
Supplied and fixed MCB, Double pole, 240 Volts, of 6-32 amps current rating of 10 KA complete all as directed by Engr-in-charge.
S&F LED tube light fixture environmental friendly energy efficient of 20W LED 6500K and above (4') including electric connection with PVC copper flexible twin core cable, 1.0 sqmm from ceiling rose to light fitting complete all as specified and directed by Engr-In-charge.
M&L for Earthing complete with GI earth plate electrode of size 600x600x6 mm thick buried directly in ground with earth pit not less than 2.25 meter deep below ground level with top edge of plate not less than 1.5 meter below normal ground level connected to GI wire 4 mm dia earth lead by means of nuts, bolts, check nuts, washers of galvanised iron as steel, protected by galvanized iron pipe 15 mm bore (light grade) all as directed including PCC chamber cement concrete (1:3:6) type C-2 with RCC cover, earth work in soft/loose soil, Funnel, GI protection pipe 15 mm, complete all as shown in electrical plate No 3 of SSR Part I including testing on completion all complete as specified and directed. Note : GI wire upto 7.5m including testing consider in quoted rate.
S&F Lamp holder, PVC/Polycarbonate type with back plate suitable for batten fittings with LED bulb 09 watt complete all as specified.
S&F sheet metal enclosure for DB's SPN 230 volts 04 way with 200 amps rated bus bar neautral link, earth bar double door complete all as specified and directed.
Supply, laying and commissioning of XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 16 Sqmm with 02 core complete all as specified and directed.
M & L for sand cushioning with dry coarse sand to under ground cable 23 cm thick, 8 cm thick below the cable and 15 cm thick after laying the cable complete all as specified and directed by Engineer-in-Charge. Note : Thickness after punning shall be considered for payment.
Supply and laying reinforced precast concrete cable cover Class LV, Type I, flat, size 250mm x 150mm x 40mm complete all as specified and directed.
Supply and install steel tubular swaged poles type 410 SP-31 ( 9.0 metres long) complete with CI based plate and finial including painting of poles with two coats of synthetic enamel paint over a coat of primer black and white/yellow strips 30CM wide each (05 Nos) up to 1.5 Mtrs height from coping & numbering of poles complete all as specified and directed
Supply, laying and testing cable XLPE Insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 16 Sqmm 4 core complete all as specified and directed.
Supply, laying and testing cable XLPE Insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 10 Sqmm 2 core complete all as specified and directed.
Supply and fix hot moulded FRP looping /Junction box size 280 mmx200 mm for street light poles with locking arrangement and suitable connection for three phase incomming cable 3 phase out going cable and single phase connection for light fitting incl controlled MCB SP-10 Amps -01 Nos enclosed in thermo plastic in closed shock proof safe IP-65, weather,vermin proof,dust and water proof complete with two nos cables entry incl gland of standard size with suitable size mild steel clamps to fixed on pole complete all as specified.
Supply and fixing LED street light fitting 70 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete all as specified and directed.
Supply and fixing LED flood light 100 watt 230 V AC outdoor type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistan complete with driver and lamp complete all as specified and directed.
M&L for PVC Flexible 3 core multistranded copper conductor cable of size 2.5 sqmm, PVC insulated unsheathed 1100 Volts grade drawing in and including appropriate dia. PVC conduits heavy duty and conduit fittings complete all as specified.
S&F Mount LED Bollard light (Turin LED Bollard) 10 watt IP 65 with excellent light out put through its PMMA window ensuring maximum illumination aspect in surrounding complete all as specified and directed.
M&L for Cement concrete in foundations, filling and mass concrete Type C2, 1:3:6, using 40 mm graded stone aggregate for copping complete all as specified and directed.
M&L for Cement concrete in foundations, filling and mass concrete Type B2, 1:2:4, using 20 mm graded stone aggregate complete all as specified and directed.
M & L MS work for febrication of iron pit cover, gate valve chamber cover,etc. as required MS angle iron of required size , MS sheet cover, cross arms, bracing, supports, clamps structual steel section including nuts,bolts, washers, welding, bending, cold or hot drilling holes for bolts in any shape or size and including of one coat of primer and one finishing coat of paint complete all as specified and directed by Engr-in-charge.
M&L for anti termite treatment (Pre treatment) treating the backfill in contact with foundation at the rate of 7.5 ltrs of emulsion per square meter of vertical surface (area of the slab structure in contact with backfill to be measured) complete all as specified and directed.
M&L for anti termite treatment the top surface of filled earth @ 5 ltrs emulsion per square meter of surface complete all as specified and directed.
M&L for anti termite treatment the soil under plinth protection @ 5 ltrs emulsion per square meter of surface complete all as specified and directed.
Excavating over areas in soft/loose soil nexc 1.5 mtr deep and getting out complete all as specified and directed.
M&L for RCC NP2 150mm dia pipes laid on150mm thick bed and depth with excavation in any type of soil, including man holes/drop manhole of standard size made of brick masonry/RCC precast RCC including all items.
M&L for preparing new concrete surfaces and apply two coats of synthetic enamel paint over a coat of primer all as specified and directed.
PAREEK AND COMPANY (BID ID -3298827)
RANDHIR AND COMPANY (BID ID -3298533)
SHRI SHYAM CONSTRUCTION CO. (BID ID -3293878)
V R TRADERS (BID ID -3294278)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .