Loading…
Loading…
Tender Value
₹4.2 Cr
EMD Value
₹5.0 L
Closing Date
27 Jul 2026, 6:00 pm
HQ CHIEF ENGINEER PATHANKOT ZONE
HQ CHIEF ENGINEER PATHANKOT ZONE
PROVISION OF SEWAGE TREATMENT PLANT (STP) AT BHADURIYA COMPLEX UNDER GE (SOUTH) PATHANKOT
2026_MES_766892_1
CA NO CEPZ-20/2025-26
Open Tender
Civil Works
3060 days
GE (South) Pathankot
As per tender documents
8 documents required · 8 mandatory
₹2,000
Yes
GE (South) Pathankot
₹5.0 L
Yes
21 May 2026
21 May 2026
3 Aug 2026
21 May 2026
27 Jul 2026
20 Jul 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | SEWAGE TREATMENT PLANT (75 KLD CAPACITY) Design,Supply, installation, testing and commissioning of underground Package Sewage Treatment System of capacity 75 KLD made of 100% FRP, with in build standard manholes and manhole cover based on any suitable technology/method as per Geographical location, temperature differential and rainfall complete with Mechanical, Electrical with tertiary treatment facilities to achieve desgined Parameters of Sewage. Complete sewage treatment plant to be provided as per the details given in Schedule 'A" Part-I from page No 36 to 39 of CA. | 1 | Each Job | - | - |
| 2 | Supplying, Developing, Installing and Commission SCADA System for 75 KLD Sewage Treatment Plant along with various Automation equipment for STP as indicated and as per details attached. The STP SCADA system shall comprise Complete Sewage Treatment Plant of capacity 75 KLD to be provided as per the details given in Schedule 'A" Part-I from page No 40 of CA. | 1 | Each Job | - | - |
| 3 | Supply, Installation , Testing and commissioning of CPRI APPROVED extendable, compartmentalised, front operated , back openable, LT cubicle STP panel having ingress protection of IP 54, suitable for operation on 415 Volt 3 phase 50 c/s power supply fabricated out of 2 mm thick CRCA sheet steel and base channel of MS section not less than 100mmX50mmX5mm, gland plate of 3 mm thick cleaned and treated in 7 tank process and powder coated with approved shade with TPN Electrolytic Aluminium busbar of 200 Amps duly insulated in colour coding & suitable to withstand 25 MVA fault lavel complete with supplying & installation of following equipment including interconnection, control wiring etc as required. All MCCBs shall have microprocessor based release & shall have manually operated handle.It includes all wiring , cabling of required sizes from STP panel board to each electrical parts with on site control panel for individual motors . The panel shall be consists of under mentioned Items/accessories (Panel shall be of outdoor type installation with suitable IP Protection) :-
(a) Incomming :-
(i) 100Amp, 4 Pole, MCCB (25KA) with Microprocessor =01 No
(ii) R.Y.B Phase indication lamp with fuse =1 set.
(iii) 0-100 Amp Digital Ammeter 150/5A Class 10 = 1 set
(iv) 0-500V Digital Voltometer with Control MCB =1 set
(b) Out Going :-
(i) 40 Amp, TP MCCB 15KA ICS with automatic star delta Starter as per type -2 cordination with single phase preventer under/ overvoltage protection,overload and short circuit protection,R.Y.B Phase indication lamp with fuse 1 set. - 2 sets (For Two Numbers Air blowers , 110m3/hr. (0.50 wc) 5.0HP motor each). Blower Model Number : AB 4130
(ii) 10A TP MCCB 10KA ICS with automatic DOL Starter as per type -2 cordination with single pahse preventer under/overvoltage protection,overload and short circuit protection,R.Y.B Phase indication lamp with fuse 1 set of 2 numbers(One Working +One standby) (For Wet Well Submercible sewer pumps ,Qty : Two Numbers ,2.0 H.P each pump(1 working + one standby) Discharge 3.6 m3/hr.10m head.
(iii) 6A TP MCCB 10KA ICS with automatic DOL Starter as per type -2 cordination with single pahse preventer under/overvoltage protection,overload and short circuit protection,R.Y.B Phase indication lamp with fuse 1 set. -1 nos: (For One number anoxic tank submerged mixer ,1.0 HP each) Model SUZ/RW3033 | 1 | Each Set | - | - |
| 3.01 | Item no. 3 (contd...)
(iv) 10A TP MCCB 10KA ICS with automatic star delta Starter as per type -2 cordination with single pahse preventer under/overvoltage protection,overload and short circuit protection,R.Y.B Phase indication lamp with fuse 1 set. -2 nos(One working+one standby) (For Two Numbers RAS pumps ,2 H.P each) 150LPM.
(v) 6A TP MCCB 10KA ICS with automatic star delta Starter as per type -2 cordination with single pahse preventer under/overvoltage protection, overload and short circuit protection,R.Y.B Phase indication lamp with fuse 1 set. - Two numbers (One Working+One Standby) Filter press feed pumps , 0.5 H.P each).
(vi) 6A TP MCCB 10KA ICS with automatic star delta Starter as per type -2 cordination with single pahse preventer under/overvoltage protection, overload and short circuit protection,R.Y.B Phase indication lamp with fuse . -2 nos: (For One number Filter Press Hydraulic press machine motor , 0.5 H.P.
(vii) 10A TP MCCB 10KA ICS with DOL starter as per type -2 cordination with single pahse preventer under/overvoltage protection,overload and short circuit protection,R.Y.B Phase indication lamp with fuse 1 set. -2 nos: (For Two numbers(One working +one standby) PERMEATE PUMPS 1.5 HP each pump) 4.0 m3/hr. Head : 20mWC (Two numbers ) VFD operated.
(viii) 10A TP MCCB 10KA ICS with DOL starter as per type -2 cordination with single pahse preventer under/overvoltage protection,overload and short circuit protection, R.Y.B Phase indication lamp with fuse 1 set. -2 nos: (For One numbers Air compressor motor 2.0 HP each pump) 200 LPM , 125 psi pressure.
(ix) 6A TP MCCB 10KA ICS with DOL starter as per type -2 cordination with single pahse preventer under/overvoltage protection,overload and short circuit protection,R.Y.B Phase indication lamp with fuse 1 set. -2 nos: (For Two numbers (1 Working +One standby) MBR C.I.P Pumps and other fitting parts , 1.0 HP each)
(x) 6A DP MCB 10KA ICS with under/overvoltage protection,overload and short circuit protection, indication lamp with fuse 1 set. -2 nos: (For SIX numbers Pneumatic Valves with flange fitting parts each)
(xi) 6A DP MCB under/overvoltage protection,overload and short circuit protection,R.Y.B Phase indication lamp with fuse 1 set. -2 nos: (For Two numbers Citric Acid Dosing Pumps ) | - | - | - | - |
| 3.02 | Item no. 3 (contd...)
(xii) 6A TP MCCB 15KA ICS with DOL starter as per type -2 cordination with single pahse preventer under/overvoltage protection,overload and short circuit protection,R.Y.B Phase indication lamp with fuse 1 set. -2 nos: (For Two numbers CITRIC ACID MIXER ,
0.5 HP each)
(xiii) 6A DP MCB under/overvoltage protection,overload and short circuit protection,R.Y.B Phase indication lamp with fuse 1 set. -2 nos: (For Two numbers Hypo Dosing Pumps )
(xiv) 6A TP MCCB 10KA ICS with DOL starter as per type -2 cordination with single pahse preventer under/overvoltage protection,overload and short circuit protection,R.Y.B Phase indication lamp with fuse 1 set. -2 nos: (For Two numbers Hypo Mixer ,0.5 HP each)
(xv) 6A TP MCCB 10KA ICS with DOL starter as per type -2 cordination with single pahse preventer under/overvoltage protection,overload and short circuit protection,R.Y.B Phase indication lamp with fuse 1 set. -2 nos: (For Two numbers Treated water Distribution Pumps, 4 HP each).
(xvi) 6A DP 10 KA for ON line Monitoring System and two number flow meters
(xvii) 16A DP 10 KA for Spare -03 Nos for PLC board.
(xviii) 32A DP 10 KA for Spare -03 Nos for STP Plant building & Street light.
(xix) Note : - Before Purchase of above said extendable, compartmentalised, front operated , back openable, LT cubicle STP panel , Drawing of Panel alongwith its Components, Items, accessories shall be submitted by the Contractor and approved by the GE. | - | - | - | - |
| 4 | SEWAGE TREATMENT PLANT (50 KLD CAPACITY)
Design,Supply, installation, testing and commissioning of underground Package Sewage Treatment System of capacity 50 KLD made of 100% FRP, with in build standard manholes and manhole cover based on any suitable technology/method as per Geographical location, temperature differential and rainfall complete with Mechanical, Electrical with tertiary treatment facilities to achieve desgined Parameters of Sewage. Complete sewage treatment plant to be provided as per the details given in Schedule 'A" Part-I from page No 41 to 44 of CA. | 1 | Each Set | - | - |
| 5 | Supplying, Developing, Installing and Commission STP SCADA System for 50 KLD Sewage Treatment Plant along with various Automation equipment for STP as indicated and as per details attached. The STP SCADA system shall comprise Complete Sewage Treatment Plant of capacity 50 KLD to be provided as per the details given in Schedule 'A" Part-I from page No 45 of CA. | 1 | Each Job | - | - |
| 6 | Supply, Installation , Testing and commissioning of CPRI APPROVED extendable, compartmentalised, front operated , back openable, LT cubicle STP panel having ingress protection of IP 54, suitable for operation on 415 Volt 3 phase 50 c/s power supply fabricated out of 2 mm thick CRCA sheet steel and base channel of MS section not less than 100mmX50mmX5mm, gland plate of 3 mm thick cleaned and treated in 7 tank process and powder coated with approved shade with TPN Electrolytic Aluminium busbar of 100A duly insulated in colour coding & suitable to withstand 25 MVA fault lavel complete with supplying & installation of following equipment including interconnection, control wiring etc as required. All MCCBs shall have microprocessor based release & shall have manually operated handle.It includes all wiring , cabling of required sizes from STP panel board to each electrical parts with on site control panel for individual motors . The panel will consists of following Items as per drawings attached.(Panel shall be of outdoor type installation with suitable IP Protection)
(a) Incomming :-(i) 63Amp,4Pole,MCCB (25KA) with Microprocessor =01 No
(ii) R.Y.B Phase indication lamp with fuse =1 set.
(iii) 0-100 A Digital Ammeter 150/5A Class 10 , 1 set
(iv) 0-500V Digital Voltometer with Control MCB 1 set
(b) Out Going :- (i) 40 Amp, TP MCCB 15KA ICS with automatic star delta Starter as per type -2 cordination with single phase preventer under/ overvoltage protection,overload and short circuit protection,R.Y.B Phase indication lamp with fuse 1 set. -2 sets (For Two Numbers Air blowers , m3/hr. ( 0.50 wc) 5.0HP motor each).Blower Model Number :AB 4130 (ii) 10A TP MCCB 10KA ICS with automatic DOL Starter as per type -2 cordination with single pahse preventer under/overvoltage protection,overload and short circuit protection,R.Y.B Phase indication lamp with fuse 1 set of 2 numbers(One Working +One standby) (For Wet Well Submercible sewer pumps ,Qty : Two Numbers ,2.0 H.P each pump(1 working + one standby) Discharge 2.4 m3/hr.10m head.
(iii) 10A TP MCCB 10KA ICS with automatic DOL Starter as per type -2 cordination with single pahse preventer under/overvoltage protection,overload and short circuit protection,R.Y.B Phase indication lamp with fuse 1 set of 2 numbers pumps (One working+one standby) (For Wet Well cutter Submercible sewer pumps ,Qty : two Numbers ,2.0 H.P each pump) Discharge 4m3/hr.10m head. | 1 | Each Job | - | - |
| 6.01 | Item no. 6(contd...)
(iv) 6A TP MCCB 10KA ICS with automatic DOL Starter as per type -2 cordination with single pahse preventer under/overvoltage protection,overload and short circuit protection,R.Y.B Phase indication lamp with fuse 1 set. -1 nos: (For One number anoxic tank submerged mixer ,1.0 HP each) Model SUZ/RW3033
(v) 10A TP MCCB 10KA ICS with automatic star delta Starter as per type -2 cordination with single pahse preventer under/overvoltage protection,overload and short circuit protection,R.Y.B Phase indication lamp with fuse 1 set. -2 nos(One working+one standby) (For Two Numbers RAS pumps ,2 H.P each) 150LPM.
(vi) 6A TP MCCB 10KA ICS with automatic star delta Starter as per type -2 cordination with single pahse preventer under/overvoltage protection, overload and short circuit protection,R.Y.B Phase indication lamp with fuse 1 set. - Two numbers (One Working+One Standby) Filter press feed pumps , 0.5 H.P each)
(vii) 6A TP MCCB 10KA ICS with automatic star delta Starter as per type -2 cordination with single pahse preventer under/overvoltage protection, overload and short circuit protection,R.Y.B Phase indication lamp with fuse . -2 nos: (For One number Filter Press Hydraulic press machine motor , 0.5 H.P.
(viii) 10A TP MCCB 10KA ICS with DOL starter as per type -2 cordination with single pahse preventer under/overvoltage protection,overload and short circuit protection,R.Y.B Phase indication lamp with fuse 1 set. -2 nos: (For Two numbers(One working +one standby) PERMEATE PUMPS
1.5 HP each pump) 3.0 m3/hr. Head : 20mWC (Two numbers ) VFD operated.
(ix) 10A TP MCCB 10KA ICS with DOL starter as per type -2 cordination with single pahse preventer under/overvoltage protection,overload and short circuit protection,R.Y.B Phase indication lamp with fuse 1 set. -2 nos: (For One numbers Air compressor motor 2.0 HP each pump) 150 LPM , 125 psi pressure.
(x) 6A TP MCCB 10KA ICS with DOL starter as per type -2 cordination with single pahse preventer under/overvoltage protection,overload and short circuit protection,R.Y.B Phase indication lamp with fuse 1 set. -2 nos: (For Two numbers (1 Working +One standby) MBR C.I.P Pumps and other fitting parts , 1.0 HP each) | - | - | - | - |
| 6.02 | Item no. 6(contd...)
(xi) 6A DP MCB 10KA ICS with under/overvoltage protection,overload and short circuit protection, indication lamp with fuse 1 set. -2 nos: (For SIX numbers Pneumatic Valves with flange fitting parts each)
(xii) 6A TP MCCB 15KA ICS with DOL starter as per type -2 cordination with single pahse preventer under/overvoltage protection,overload and short circuit protection,R.Y.B Phase indication lamp with fuse 1 set. -2 nos: (For Two numbers CITRIC ACID MIXER ,0.5 HP each)
(xiii) 6A DP MCB under/overvoltage protection,overload and short circuit protection,R.Y.B Phase indication lamp with fuse 1 set. -2 nos: (For Two numbers Hypo Dosing Pumps )
(xiv) 6A TP MCCB 15KA ICS with DOL starter as per type -2 cordination with single pahse preventer uner/overvoltage protection,overload and short circuit protection,R.Y.B Phase indication lamp with fuse 1 set. -2 nos: (For Two numbers CITRIC ACID MIXER ,0.5 HP each)
(xv) 6A DP MCB under/overvoltage protection,overload and short circuit protection,R.Y.B Phase indication lamp with fuse 1 set. -2 nos: (For Two numbers Hypo Dosing Pumps )
(xvi) 6A TP MCCB 10KA ICS with DOL starter as per type -2 cordination with single pahse preventer under/overvoltage protection,overload and short circuit protection,R.Y.B Phase indication lamp with fuse 1 set. -2 nos: (For Two numbers Hypo Mixer ,0.5 HP each)
(xvii) 6A TP MCCB 10KA ICS with DOL starter as per type -2 cordination with single pahse preventer under/overvoltage protection,overload and short circuit protection,R.Y.B Phase indication lamp with fuse 1 set. -2 nos: (For Two numbers Treated water Distribution Pumps, 3 HP each).
(xviii) 6A DP 10 KA for ON line Monitoring System and two number flow meters
(xix) 16A DP 10 KA for Spare -03 No for PLC board.
(xx) 32A DP 10 KA for Spare -03 No for STP Plant building & Street light.
(xxi) Note : - Before Purchase of above said extendable, compartmentalised, front operated , back openable, LT cubicle STP panel , Drawing of Panel alongwith its Components, Items, accessories shall be submitted by the Contractor and approved by the GE. | - | - | - | - |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.01 MB
Tender.pdf
Tender Documents • 4.69 MB
BOQ_858868.xls
BOQ • 0.38 MB
Corrigendum2.pdf
PDF • 0.28 MB
datecorrigendum1.pdf
PDF • 0.45 MB
Download all tender documents and submit your bid