Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹4.7 LAccepted-AOC | L1 | Accepted-AOC Being L1 and Most Reasobale | |
| 2 | L2₹6.1 L+₹1.2 L (24.2%)Rejected-Finance | L2 | Rejected-Finance Being Not L1 | |
| 3 | L3₹6.8 L+₹1.9 L (39.2%)Rejected-Finance NEAR CIVIL HOSPITAL WARD NO 07 VPO CHOWARI DISTT CHAMBA HP 176302 | CHOWARI | CHAMBA | HP | 176302 | L3 | Rejected-Finance Being Not L1 |
Tender Value
Refer Docs
EMD Value
₹17,000
Closing Date
17 Dec 2022, 6:00 pmClosed
AGE(I) DALHOUSIE
AGE(I) DALHOUSIE PIN-176305
REPAIR REPLACEMENT CLEANING OF SEWAGE LINE SEPTIC TANKS SOAKAGE WELLS MANHOLES AND DRAINS AT DALHOUSIE
2022_MES_563589_1
8918/2022-23/E8
Open Tender
Civil Works
Item Rate
365 days
AGE(I) DALHOUSIE
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
Yes
AGE(I) DALHOUSIE
₹17,000
Yes
AGE(I) DALHOUSIE
16 Mar 2023
17 Nov 2022
19 Dec 2022
17 Nov 2022
17 Dec 2022
2 Dec 2022
17 Nov 2022 - 28 Nov 2022
28 Nov 2022
Amount
Demolition of brick work built in CM including all quoins pillars etc.complete all as specified and as directed.
Demolition of cement concrete/RCC of any description and in any position not other wise specifically provided for.
Demolition and breaking up drain pipes (salt glazed ware ) set in cement mortar of 150/100mm incl demolation of existing PCC packing and haunching against the sides of pipe complete all as specified and as directed.
Dismantling floor hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish of the premises complete all as specified and as directed.
Taking down cement plaster of any description on brick work and concrete wall incl raking out joints hacking for key and scrubbing down with water complete all as specified and as directed.
Cleaning of septic tank any capacity and depth including chambers, outlet chamber removing out all scum silt, residue both organic and inorganic nature after plugging the incoming sewage lines removing and depositing the water at a distance not less than 20m and burying in ditch, finally covering the ditch with earth and spraying unslacked lime on the covered ditch as well as around the septic tank to make hygienic including excavation of ditch placing of manhole cover after cleaning etc complete as specified and directed by Engineer –In Charge.
Cleaning of sewage line 100mm dia/ 150 mm dia laid in any slope or gradient and depth 3 mtr by roding taking out all residue from the lines/manholes including water depositing at a distance not less than 20 mtr in ditch finally covering the ditch with earth and spraying unslacked lime on the covered ditch as well as around the manholes to make hygienic including excavation of ditch testing of line by furnishing water after cleaning etc complete all as specified and directed by Engineer-in-Charge.
All as per srl item No 07 above but CI pipes fixed with wall of 75/100mm dia complete all as specified and as directed.
All as per srl item No 07 above but CI pipe fitting upto 100mm dia, embedded in ground or first floor complete all as specified and directed by Engr-in-Charge
Cleaning/clearing of IWC/EWC by roding, taking out all residue including waste and testing by pouring water after cleaning etc complete all as specified and directed by Engr-in-Charge.
Excavation in trenches n. exc. 1.5 m wide and n. exc. 1.5 m in depth for foundations etc. or for shafts, wells, cesspits, manhols, pier holes etc n. exc 10 sqm on plan and not exc 1.50 meter in depth and getting out in soft/loose soil.
Returning filling in, incl. spreading leveling, watering and well ramming in layers not exc. 25 cms in soft/ loose soil.
Removing excavated material (soil) n. exc. 50Mtr and depositing where directed at a level n.exc 1.5m above the starting point.
M&L for plain cement concrete 1:4:8 as in foundation type D-2 using 40mm graded crushed stone aggregate all as specified and as directed
M&L for plain cement concrete 1:2:4 type B-1 using 20mm graded aggregate as in benching, coping including watering slightly rounded or chamfered angles and throating including necessary form work complete all as specified and as directed..
Precast cement concrete 1:2:4 type B-1 using 20mm graded crushed s tone aggregate type B-1 as in manhole /slab cover all as specified and set in CM 1:4 complete all as specified and as directed.
M/L Reinforced cement concrete nominal mix in type B1 1:2:4 (20mm graded stone aggregate) slabs supported on walls, beams, and columns, in floors, roof, landings, balconies, canopies, deck slab and in shelves and the like all as specified.
Brick work with sub class B brick straight or curved on plan exc 6 m mean radius in CM 1:4 complete all as specified and as directed.
TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and as directed.
Rendering 15mm thick cement plaster in CM 1:4 on fair faces of brick work with WPC finished even and smooth without using extra cement complete all as specified and as directed.
Supply only water proofing compound
Concrete bed to drain pipe including packing and haunching against the sides of pipe after they are laid and tested for 150 mm bore pipe in PCc 1:4:8 type D-2 using 40mm graded stone aggregate complete all as specified and as directed.
S & F 110 mm PVC (SWR) pipes single socketed in any length with rubber ring jionts laid trenches or in floors
Cutting into existing manhole for connecting new drains and making good to pipes and rendering cutting out existing benching for and forming branching for and forming branch channel (1/2 round or ¼ section ) in PCC 1:2:4 type B-1 using 20mm graded crushed stone aggregate smooth finished and reforming benching as specified and directed for 150mm dia of pipe complete all as specified.
S&F Cast Iron soil Waste and Vent pipe in any length with or without ears with cement joints laid in in floors/wall of 100mm bore all as specified complete all as specified and fixed in repair complete all as specified and as directed.
All as pe item No 25 above but fixed to wall of 75mm bore pipe
As per item No 25 but 50 mm dia fixed to wall
Bends ( any radius ) with duck foot or heal rest for 100 mm bore pipe fixed in repair including taking out old fittings complete all as specified.
All as per srl item No 28 above but 75mm bore pipe
S&F in repairs Cast iron fioor trap with grating including jointing to waste pipe with dia of outflow 100mm fixed in cement concrete type B 1(1:2:4) complete all as spd
S&F vitreous china wash down water closet pan EWC(pedestal pattern),white excluding fixing bolts of flushing cistern and flush pipe in repairs
Supply only plastic closet seat ,coloured ,closed pattern with flat bottom and cover and mild steel chromium plated or aluminised hinhing device.
Vitreous china squatting pan of pattern long pan size 580mm white with ‘P’ or ‘S’ trap front or back inlet and foot rests any pattern including connection to trap and flush pipe etc complete including making good the floor with existing finish fixed in repairs, Make -Hindware cat part No 20042.
Vitreous China urinals, bowl type (back or corner wall type) of size 465x355x265 mm , complete including providing and fixing plugs, bedding urinal against wall in cement mortar 1:2, securing urinal to plugs with and including 60mm long brass screws, pointing around urinal back in cement; incl brackets, flush pipe and Union for discharge pipe complete all as pecified and as directed.
S&F PVC flushing Cistern of 10 Ltr capacity of low level incl connection to WC and making good including bracket.Make Hindware (Sleek)/Jindal (Slim)
M & L screed bed or beding layer of CM 1:4 15mm thick for laying floor finishes complete all as specified.
M & L Non skid ceramic tiles 7 to 8 mm thick 300x300mm coloured in floors etc set and jointed in neat cement slurry complete all as specified.
S&F in repairs Stack clamps out of 50mm by 5mm flat iron & 16mm dia round iron stays, including bolts & nuts & securing ends of stay to wall or roof for 100 mm bore CI pipe
S&F Stack in repairs clamps out of 50mm by 5mm flat iron & 16mm dia round iron stays, including bolts & nuts & securing ends of stay to wall or roof for 75 mm bore CI pipe complete all as pecified and as directed.
S&F for PVC (SWR) pipes of 75mm dia single socketed in any length with rubber ring joints laid in trenches or in floor complete all as specified.
S&F 110 mm PVC WC connector with lip ring complete all as specified
S&F PVC (SWR) bends ( any radius ) with duck foot or heal rest for 110mm bore pipe fixed in repair including taking out old fittings complete all as specified.
All as per srl item No 42 above but 75mm bore pipe
PVC (SWR) branch pieces single (equal or unequal) ordinary or inverted (spigot or socket type ) or with parallel branches for 110mm bore pipe fixed in repair including taking out old fitting complete all as directed with oval access door fixed in repairs complete all as pecified and as directed.
All as per item No. 44 above but 75mm bore pipe.
Demolition of cement concrete (unreinforcement) of any discription and in any position not otherwise specificcally provided for
PCC 1:2:4 type B-1 (using 20 mm graded stone aggregate) as in surface channel drains all as specified and directed.
M&L extra over forming fair finished drains or channel 30 cm inner girth in cement concrete using extra cement including forms, moulds, mitred/ stopped ends etc
Roshan Lal Thakur
m/S Varun Gupta
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .