Loading…
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹80.6 LAccepted-AOC ERODE 638 152 | ERODE | TAMIL NADU | 638152 | L1 | Accepted-AOC Accepted | |
| 2 | L2₹87.1 L+₹6.5 L (8.03%)Rejected-Finance 9 A PONGALIVALASU KODUMUDI POST ERODE 638 151 | ERODE | ERODE | TAMIL NADU | 638151 | L2 | Rejected-Finance Reject | |
| 3 | Rejected-Technical NEW NO 4 136 OLD NO 1 177 BHARATHIYAR STREET SINGAPERUMAL KOIL CHENGALPATTU DISTRICT 603 204 | SINGAPERUMAL KOIL | CHENGALPATTU | TAMIL NADU | 603204 | - | Rejected-Technical Technically Rejected | |
| 4 | Rejected-Technical CHENNAI | CHENNAI | TAMIL NADU | 600001 | - | Rejected-Technical Technically Rejected |
| Sl No | Description | Qty | Unit | Sri Balaji Constructions L2 | VRR CONSTRUCTION L1 |
|---|---|---|---|---|---|
| 1.00 | 11KV RMG (2 nos - VCB + 1 nos - VCB)
11 kV RMG (OUTDOOR TYPE)
Supply, Testing, Commissioning of 11kv RMG Panel having ( 2 nos - VCB + 1 nos - VCB) as per KK Nagar MRT Specifications with following parameters
11kV 630A 25kA Horizontal Drawout type:
Vaccum Circuit Breaker Comprising of :- 2 nos - Incoming Feeder
i. Motor/Manual spring charging mechanism - 230V AC
ii. Closing & Tripping Coil suitable for 110V DC
iii. 8 NO + 8 NC Auxiliary Switch
11kV 630A 25kA Horizontal Drawout type:
Vaccum Circuit Breaker Comprising of : - 1 nos - Outgoing Feeder
i. Motor/Manual spring charging mechanism - 230V AC
ii. Closing & Tripping Coil suitable for 110V DC
iii. 8 NO + 8 NC Auxiliary Switch
iv. Mechanical ON/OFF Indication
v. Mechanical Spring charge/Discharge Indication
vi. Breaker Position Indicator
vii. Mechancial Operating Counter
viii. Automatic Safety Shutters
ix. Secondary self-aligned plug in contacts
x. Anti-Pumping feature
xi. Vacuum Interrupter-3 Nos.
Indicating Lamps/Push Buttons :
R,Y,B Phase Indication Lamps - 1 Set in Incomer
LBS ON/OFF Indicating Lamps - 1 Set in Outgoing
Breaker ON/OFF Indicating Lamps - 1 Set in Incomer
Spring charging Indication Lamp - 1 no in Incomer
Trip Circuit Healthy Indication Lamp & push button - 1 no in Incomer
Trip Indication Lamp - 1 no in Incomer
Busbar Rating: 630A - TP - COPPER
Main Busbar : 50mm x 10mm x 1 Run per phase - 1 set in Incomer/Outgoing
Earth Busbar : 40mm x 06mm - 1 set in Incomer/Outgoing
Miscellaneous Items:
Power pack (IP: 230V AC/ OP: 110V DC) - 1 no in Incomer
Surge Arrester (10KV,10KA) - 1 set in Incomer
Test Terminal Block - 1 no in Incomer
Trip/Neutral/Close Switch - 1 no in Incomer
Mechancial Interlock (Shall be provided, if necessary) - 1 no in Incomer
PTC Heater with Hygrostat - 1 no in Incomer/Outgoing
Control Fuses, Ferrules & Wiring etc., - 1 no in Incomer/Outgoing
Power Terminals suitable to receive XLPE without termination kit - 1 set PWD SOR 2025-26 M-1958 | 1 | Nos | 9,00,000 ₹10,62,000 | 7,50,000 ₹8,85,000 Lowest |
| 2.00 | 11KV SINGLE PANEL HT VCB - OUTDOOR TYPE
Supply, Testing, Commissioning of 11kv HT VCB Outdoor Type having the following specifications
11KV,630A,26.3kA/3Sec Horizontal Drawout type - 1 nos
Vaccum Circuit Breaker Comprising of :-
i. Motor/Manual spring charging mechanism - 230V AC - 1 nos
ii. 3Nos. Vacuum Interupters - 1 nos
iii. Closing & Tripping Coil suitable for 110V DC - 1 nos
iv. 8 NO + 8 NC Auxiliary Switch - 1 nos
v. Mechanical ON/OFF Indication - 1 nos
vi. Mechanical Spring charge/Discharge Indication - 1 nos
vii. Breaker Position Indicator - 1 nos
viii. Mechancial Operating Counter - 1 nos
xi. Automatic Safety Shutters - 1 nos
x. Secondary self-aligned plug in contacts - 1 nos
xi. Anti-Pumping feature - 1 nos
11kV Epoxy Resin Cast Dual Core Current Transformer - 3 nos
Ratio: As per site requirement.
Core I: Cl:0.5, 15VA for Metering
Core II: Cl: 5P10 , 15VA for Protection
11kV Epoxy Resin Cast Three Phase Potential Transformer -1 nos
Ratio : 11kV/v3,110V/v3 (Fixed type)
Core I: Cl: 0.5, 100VA for Metering PWD SOR 2025-26 M-1953
Meters:
Digital Ammeter - 1 nos
Digital Voltmeter - 1 nos
Digital Multifunction Meter - 1 nos
Relays:
Numerical O/C+E/F protection relay - 1 nos
High speed Tripping relay - 1 nos
Transformer Auxilary Relay - 2 nos
Indicating Lamps/Push Buttons :
R,Y,B Phase Indication Lamps -1 set
Breaker ON/OFF Indicating Lamps - 1 nos
Spring charging Indication Lamp - 1 nos
Trip Circuit Healthy Indication Lamp & Push Button - 1 nos
Trip Indication Lamp - 1 nos
Busbar Rating : 630A TP Aluminium - 1 set
Main Busbar : 50mm x 08mm x 2 Run per phase
Earth Busbar: 50mm x 06mm
Miscellaneous Items
8 Window Annunciator with Hooter - 1 nos
Surge Arrester (10KV 10KA) - 1 nos
Power Pack (IP: 230V AC/OP: 110V DC) - 1 nos
TNC & L/R Switch - 1 nos
PTC Heater with Hygrostat - 1 nos
TBs, Control Fusess, Ferrules & Wiring etc. - 1 set
Power Terminals suitable to receive XLPE cable without termination kit - 1 set | 1 | No | 7,00,000 ₹8,26,000 | 5,10,000 ₹6,01,800 Lowest |
| 3.00 | Earthing arrangements with GI Earth Plate including charcoal and salt with necessary excavation in all soils and to full depth as may be required and masonry work, re-filling the sides of foundation with excavated earth as per the standard specification and as directed by the Departmental Officers. Asper PWD SOR 2025-26 M-0827 | 6 | nos | 48,000 ₹56,640 | 41,994 ₹49,552.92 Lowest |
| 4.00 | Supply & Erection of 25 X 3mm Copper Flat for Earthing PWD SOR 2025-26 M-1611 | 110 | Kg | 66,000 ₹77,880 | 64,570 ₹76,192.6 Lowest |
| 5.00 | 11KV/433V, 1000 KVA OUTDOOR TRANSFORMER
Supply & installation, testing and commissioning of 11kv 1000 KVA outdoor type oil cooled with ONAN, OLTC/RTTC having HV side cable box and LV side busduct flange box with necessary wheeling arrangement with level -1 losses as per IS : 1180 - 1 Nos PWD SOR2025-26 M-1940 | 1 | No | 26,00,000 ₹30,68,000 | 23,00,000 ₹27,14,000 Lowest |
| 6.00 | Earthing arrangements with GI Earth Plate including charcoal and salt with necessary excavation in all soils and to full depth as may be required and masonry work, re-filling the sides of foundation with excavated earth as per the standard specification and as directed by the Departmental Officers. Asper PWD SOR 2025-26 M-0827 | 2 | Nos | 13,998 ₹16,517.64 Lowest | 13,998 ₹16,517.64 Lowest |
| 7.00 | Supply & Erection of 40mm dia 8 feet (2.75mtr) long GI 'B' Class Earth pipe with clamping and funnelling arrangement burried in the underground with 600x600x2mm copper plate, mixed with charcoal and salt along with construction 450 X 450 RCC earth manual with cover as per IS 3043 PWD SOR 2025-26 M-1616 | 2 | Nos | 23,400 ₹27,612 Lowest | 23,400 ₹27,612 Lowest |
| 8.00 | Supply and Erection of 50x6mm Cu. Flat for body Earth PWD SOR 2025-26 M-1614 | 200 | Kg | 1,00,000 ₹1,18,000 Lowest | 1,00,000 ₹1,18,000 Lowest |
| 9.00 | Supply and Erection of 70x10mm Cu. Flat for Neutral Earth PWD SOR 2025-26 M-1614 | 200 | Kg | 1,00,000 ₹1,18,000 Lowest | 1,00,000 ₹1,18,000 Lowest |
| 10.00 | Supply & Laying of 11KV, 3C X 185sqmm,(Earthed) AL.AR.XLPE HT cable AS per PWD SOR 2025-26 M-1959 | 50 | Mtr | 85,000 ₹1,00,300 Lowest | 85,000 ₹1,00,300 Lowest |
Tender Value
₹99 L
EMD Value
₹99,000
Closing Date
12 Jan 2026, 3:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Commissioner Tambaram Corporation
No.01,MRM STREET, WEST TAMBARAM,CHENNAI-45
Supply and Installation of High tension power source 11KV RMG, HT VCB and Concerned Electrical Accessories to New Corporation Office Building in Tambaram City Municipal Corporation
2026_DMA_639206_8
1648/2025/E1
Open Tender
Civil Works
Works
60 days
Tambaram Corporation
Supply and Installation of High tension power source 11KV RMG, HT VCB and Concerned Electrical Accessories to New Corporation Office Building in Tambaram City Municipal Corporation
3 documents required · 3 mandatory
₹10,000
₹99,000
27 Oct 2026
6 Jan 2026
12 Jan 2026
6 Jan 2026
12 Jan 2026
6 Jan 2026
11KV RMG (2 nos - VCB + 1 nos - VCB) 11 kV RMG (OUTDOOR TYPE) Supply, Testing, Commissioning of 11kv RMG Panel having ( 2 nos - VCB + 1 nos - VCB) as per KK Nagar MRT Specifications with following parameters 11kV 630A 25kA Horizontal Drawout type: Vaccum Circuit Breaker Comprising of :- 2 nos - Incoming Feeder i. Motor/Manual spring charging mechanism - 230V AC ii. Closing & Tripping Coil suitable for 110V DC iii. 8 NO + 8 NC Auxiliary Switch 11kV 630A 25kA Horizontal Drawout type: Vaccum Circuit Breaker Comprising of : - 1 nos - Outgoing Feeder i. Motor/Manual spring charging mechanism - 230V AC ii. Closing & Tripping Coil suitable for 110V DC iii. 8 NO + 8 NC Auxiliary Switch iv. Mechanical ON/OFF Indication v. Mechanical Spring charge/Discharge Indication vi. Breaker Position Indicator vii. Mechancial Operating Counter viii. Automatic Safety Shutters ix. Secondary self-aligned plug in contacts x. Anti-Pumping feature xi. Vacuum Interrupter-3 Nos. Indicating Lamps/Push Buttons : R,Y,B Phase Indication Lamps - 1 Set in Incomer LBS ON/OFF Indicating Lamps - 1 Set in Outgoing Breaker ON/OFF Indicating Lamps - 1 Set in Incomer Spring charging Indication Lamp - 1 no in Incomer Trip Circuit Healthy Indication Lamp & push button - 1 no in Incomer Trip Indication Lamp - 1 no in Incomer Busbar Rating: 630A - TP - COPPER Main Busbar : 50mm x 10mm x 1 Run per phase - 1 set in Incomer/Outgoing Earth Busbar : 40mm x 06mm - 1 set in Incomer/Outgoing Miscellaneous Items: Power pack (IP: 230V AC/ OP: 110V DC) - 1 no in Incomer Surge Arrester (10KV,10KA) - 1 set in Incomer Test Terminal Block - 1 no in Incomer Trip/Neutral/Close Switch - 1 no in Incomer Mechancial Interlock (Shall be provided, if necessary) - 1 no in Incomer PTC Heater with Hygrostat - 1 no in Incomer/Outgoing Control Fuses, Ferrules & Wiring etc., - 1 no in Incomer/Outgoing Power Terminals suitable to receive XLPE without termination kit - 1 set PWD SOR 2025-26 M-1958
11KV SINGLE PANEL HT VCB - OUTDOOR TYPE Supply, Testing, Commissioning of 11kv HT VCB Outdoor Type having the following specifications 11KV,630A,26.3kA/3Sec Horizontal Drawout type - 1 nos Vaccum Circuit Breaker Comprising of :- i. Motor/Manual spring charging mechanism - 230V AC - 1 nos ii. 3Nos. Vacuum Interupters - 1 nos iii. Closing & Tripping Coil suitable for 110V DC - 1 nos iv. 8 NO + 8 NC Auxiliary Switch - 1 nos v. Mechanical ON/OFF Indication - 1 nos vi. Mechanical Spring charge/Discharge Indication - 1 nos vii. Breaker Position Indicator - 1 nos viii. Mechancial Operating Counter - 1 nos xi. Automatic Safety Shutters - 1 nos x. Secondary self-aligned plug in contacts - 1 nos xi. Anti-Pumping feature - 1 nos 11kV Epoxy Resin Cast Dual Core Current Transformer - 3 nos Ratio: As per site requirement. Core I: Cl:0.5, 15VA for Metering Core II: Cl: 5P10 , 15VA for Protection 11kV Epoxy Resin Cast Three Phase Potential Transformer -1 nos Ratio : 11kV/v3,110V/v3 (Fixed type) Core I: Cl: 0.5, 100VA for Metering PWD SOR 2025-26 M-1953 Meters: Digital Ammeter - 1 nos Digital Voltmeter - 1 nos Digital Multifunction Meter - 1 nos Relays: Numerical O/C+E/F protection relay - 1 nos High speed Tripping relay - 1 nos Transformer Auxilary Relay - 2 nos Indicating Lamps/Push Buttons : R,Y,B Phase Indication Lamps -1 set Breaker ON/OFF Indicating Lamps - 1 nos Spring charging Indication Lamp - 1 nos Trip Circuit Healthy Indication Lamp & Push Button - 1 nos Trip Indication Lamp - 1 nos Busbar Rating : 630A TP Aluminium - 1 set Main Busbar : 50mm x 08mm x 2 Run per phase Earth Busbar: 50mm x 06mm Miscellaneous Items 8 Window Annunciator with Hooter - 1 nos Surge Arrester (10KV 10KA) - 1 nos Power Pack (IP: 230V AC/OP: 110V DC) - 1 nos TNC & L/R Switch - 1 nos PTC Heater with Hygrostat - 1 nos TBs, Control Fusess, Ferrules & Wiring etc. - 1 set Power Terminals suitable to receive XLPE cable without termination kit - 1 set
Earthing arrangements with GI Earth Plate including charcoal and salt with necessary excavation in all soils and to full depth as may be required and masonry work, re-filling the sides of foundation with excavated earth as per the standard specification and as directed by the Departmental Officers. Asper PWD SOR 2025-26 M-0827
Supply & Erection of 25 X 3mm Copper Flat for Earthing PWD SOR 2025-26 M-1611
11KV/433V, 1000 KVA OUTDOOR TRANSFORMER Supply & installation, testing and commissioning of 11kv 1000 KVA outdoor type oil cooled with ONAN, OLTC/RTTC having HV side cable box and LV side busduct flange box with necessary wheeling arrangement with level -1 losses as per IS : 1180 - 1 Nos PWD SOR2025-26 M-1940
Earthing arrangements with GI Earth Plate including charcoal and salt with necessary excavation in all soils and to full depth as may be required and masonry work, re-filling the sides of foundation with excavated earth as per the standard specification and as directed by the Departmental Officers. Asper PWD SOR 2025-26 M-0827
Supply & Erection of 40mm dia 8 feet (2.75mtr) long GI 'B' Class Earth pipe with clamping and funnelling arrangement burried in the underground with 600x600x2mm copper plate, mixed with charcoal and salt along with construction 450 X 450 RCC earth manual with cover as per IS 3043 PWD SOR 2025-26 M-1616
Supply and Erection of 50x6mm Cu. Flat for body Earth PWD SOR 2025-26 M-1614
Supply and Erection of 70x10mm Cu. Flat for Neutral Earth PWD SOR 2025-26 M-1614
Supply & Laying of 11KV, 3C X 185sqmm,(Earthed) AL.AR.XLPE HT cable AS per PWD SOR 2025-26 M-1959
Supply & Erection of Indoor type HT Termination kit for 11KV, 3C X 185sqmm Al.Ar.XLPE HT cable PWD SOR 2025-26 M-1965
Supply & Erection of Outdoor type HT Termination kit for 11KV, 3C X 185sqmm Al.Ar.XLPE HT cable PWD SOR 2025-26 M-1967
Charges for earth Work Excavation for burring the 11kv HT Cable at a depth of 1.5 mtr and laying of RCC 'V' trough over the cable and back filling with existing soil and sand cushioning
Supply and Erection of 11KV HT Route Marker PWD SOR M1731
Supply & Laying of 4C X 2.5sqmm cu.ar.cable PWD SOR M-3075
Supply & Laying of 19C X 2.5sqmm cu.ar.cable PWD SOR 2025-26 M-3071
Supply & Laying of 3C X 2.5sqmm cu.ar.cable PWD SOR 2025-26 M-3075
Supply & Erection of 3C X 2.5sqmm cu.ar. DC gland end termination
Supply & Erection of 4C X 2.5sqmm cu.ar. DC gland end termination
Supply & Erection of 19C X 2.5sqmm cu.ar. DC gland end termination
Supply & erection of M.S. gate of size 1200mm wide & 2000mm height with all accessories,earthing of gates with braided copper including necessary civil works.Gate shall be painted with 2 coats of anticorrosive primer & 2 coats of Aluminium enamel paint.
Supply & erection of 3mtr long (65X65X6mm ISA angle with aluminium paint) for fencing with necessary concreting & all accessories as required.
Supply & fixing of chain link fencing of height 1.8mtr. From the parapet wall With necessary clamps,fasteners including all accessories as required with aluminium paint).
Supply & spreading of 40mm blue metal jelly filling upto 150mm depth over a M-sand layer Rate shall include cleaning & levelling of the yard as required at site. (from existing ground level of 150mm height) - (FOR 11kv RMG YARD + HT VCB + TRF )
Supply & Fixing of 8SWG Copper wire for Fencing Earthing SD 372
Supply, Testing, Commissioning of 14/16 SWG CRCA Sheet Siemens Grey Powder Coated Coventional Type Aluminium Bus-duct both Outdoor / Indoor having 1600A rating fed from Transformer Secondary side to Main MV Panel EB incomer Outdoor Type 1600A, TPN, Aluminium Bus-duct Outdoor type with IP-65 weather proof protection with hooding arrangement with bus-bar rating Phase : 2R X 100 X 10 mm Al.bar , Neutral : 1R X 100X 10 mm Al.bar, Earth : 2R X 50 X 6mm AL.bar the bus - bar shall have 0.8A per sq.mm and continous run of aluminium earth flat shall be provided both side of bus-ducts
Indoor Type '1600A, TPN, Aluminium Bus-duct Indoor type with with bus-bar ratingPhase : 2R X 100 X 10 mm Al.bar , Neutral : 1R X 100X 10 mm Al.bar, Earth :2R X 50 X 6mm AL.bar the bus - bar shall have 0.8A per sq.mm and continous run of aluminium earth flat shall be provided both side of bus-ducts
1600A Flexible Aluminium joints
90 degree bend
Adaptor box
LT PANEL BOARDS: 'Main Panel Design, Supply, erection, testing and commissioning of FLOOR MOUNTED CUBICLE TYPE MAIN MV PANEL with Powder Coated Painting and necessary foundation channels etc., The Board shall be incorporated with the following:- EB Incomer Instruments: Digital Multifunction meter, Maximum demand controller,Instantaneous over current, earth fault relay (2 O/C + 1 E/F) and Under voltage relay, Over voltage relay, CTs, PTs, control MCB RYB Indication lamps and "ON/OFF/Trip" indicating lamp with emergency lockable push buttons 'DG Incomer Instruments: Digital multi function meter, Instantaneous over current, Under voltage relay, Over voltage relay, CTs, PTs, control MCB RYB Indication lamps and "ON/OFF/Trip" indicating lamp with emergency lockable push buttons EB Incomer - 1600A 4P, 65 KA EDO ACB with Microprocessor based releases - 1No PWD SOR 2025-26 M-1881
DG Incomer 1- 1000A 4P, 65 KA EDO ACB with Microprocessor based releases - 1No PWD SOR 2025-26 M-1879
DG Incomer 2- 630 A 4P, 50 KA MCCB with Microprocessor based releases - 1No PWD SOR 2025-26 M-1861
Bus coupler - 1600 A 4P, 65 KA EDO ACB with Microprocessor based releases - 1No
INTERLOCKING ARRANGEMENT : 'Electrical Interlocking arrangement shall be provided between the EB incomer and DG Incomer 1 & 2 and Bus Coupler 'Outgoing Feeders: 1000A TP, 65 KA MDO ACB with Microprocessor based releases - 1No (APFCR) PWD SOR 2025-26 M-1879
800A TP, 65 KA MDO ACB with Microprocessor based releases - 3No ( RS1 & 2) & ( HVAC ) PWD SOR 2025-26 M-1878
Incomer-400A FP, 36KA MCCB PWD SOR 2025-26 M-1875,
Spreader Link PWD SOR 2025-26 M-1871,
Rotatery Handle PWD SOR 2025-26 M-1876,
Incomer-630A TP, 36KA MCCB PWD SOR 2025-26 M-1861,
Spreader Link PWD SOR 2025-26 M-1862,
Rotatery Handle PWD SOR 2025-26 M-1863,
2 No. of 250 AMPS MCCB PWD SOR 2025-26 M-1873
Spreader Link PWD SOR 2025-26 M-1874,
Rotatery Handle PWD SOR 2025-26 M-1871,
DUMMY Shell -1 Nos
All MCCBs shall be of Thermal magnetic Type with adjustable overloads and Adjustable short circuits All Out Going RS 485 Meter With Suitable CTs 'BUSBARS: ALUMINUM bus bar of All Switch Incoming and outgoing Bus bar including RATING: 1600 AMPS
There shall be One Set of Metering Compartment for EB Incomer incorporated with the following. Tape wound CTs of ratio 1600/5 Amps of Class 1.0 for measurement, class 5P10 for Protection and CT burden shall be 15VA 1No Tape wound CTs of ratio 1600/5 Amps of Class 1.0 to be mounted one of the phase busbars for APFCR Panel and CT burden shall be 15VA 1 No-Load Manager with RS 485 Interface with Maximum Demand Controller. RYB Indicating Lamps of LED Clustered type and Control MCBs shall be provided. Single phase preventor shall also be provided. There shall be One Set of Metering Compartment for DG Incomer incorporated with the following. 3Nos - Tape wound CTs of ratio 1600/5 Amps of Class 1.0 for measurement, class 5P10 for Protection and CT burden shall be 15VA 1 No Multi-function meter with RS-485 Interface. RYB Indicating Lamps of LED Clustered type and Control MCBs shall be provided. Single phase preventor shall also be provided.
Frabrication of MS PowderCoated Panel & Internial Wiring
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.24 MB
bid8.pdf
Tender Documents • 0.71 MB
BOQ_765740.xls
BOQ • 0.35 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .