Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹40.1 LAccepted-AOC C2 PAIXOMONTIRO APTS BEHIND NSD ALTO DABOLIM VASCO DA GAMA GOA 403 801 | SOUTH GOA | GOA | 403801 | L1 | Accepted-AOC Accepted being lowest tenderer | |
| 2 | L2₹42.1 L+₹1.8 L (4.41%)Rejected-AOC | L2 | Rejected-AOC Rejected being Other than lowest tenderer | |
| 3 | L3₹42.4 L+₹2.1 L (5.19%)Rejected-AOC | L3 | Rejected-AOC Rejected being Other than lowest tenderer | |
| 4 | L4₹42.7 L+₹2.4 L (5.97%)Rejected-AOC FLAT NO 4 VIRGINIA CO OP HOUSING SOCIETY AIR PORT ROAD CHICALIM VASCO DA GAMA GOA 403 711 | SOUTH GOA | GOA | 403711 | L4 | Rejected-AOC Rejected being Other than lowest tenderer | |
| 5 | L5₹44.3 L+₹4.0 L (9.81%)Rejected-AOC | L5 | Rejected-AOC Rejected being Other than lowest tenderer |
| Sl No | Description | Qty | Unit | M/S P S BABU L1 | M/S jvsr constructions L4 | Leela Enterprises L2 | JINTECH L3 | M/S G.N.POWAR L6 | STAR FABRICATION L5 |
|---|---|---|---|---|---|---|---|---|---|
| 1.00 | Excavation in trenches in soft/disintegrated rock, n exc 1.5 m wide and n exc 1.5m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sqm on plan and getting out complete all as specified and as directed. | 18.8 | Cum | 700 ₹13,160 Lowest | 750 ₹14,100 | 750 ₹14,100 | 750 ₹14,100 | 850 ₹15,980 | 850 ₹15,980 |
| 2.00 | M & L for plain cement concrete 1:4:8 type D-2 (using 40mm graded stone aggregate) as in foundation, filling & mass concrete complete all as specified and directed. | 1 | Cum | 4,500 ₹4,500 Lowest | 5,650 ₹5,650 | 5,650 ₹5,650 | 5,650 ₹5,650 | 5,950 ₹5,950 | 5,650 ₹5,650 |
| 3.00 | M&L for RCC M-30 Design mix (using 20 mm graded stone aggregate) as in footing, foundation beams, plinth beams, bases of columns etc. complete all as specified and directed. | 4 | Cum | 7,000 ₹28,000 Lowest | 7,500 ₹30,000 | 7,500 ₹30,000 | 7,500 ₹30,000 | 7,800 ₹31,200 | 7,500 ₹30,000 |
| 4.00 | M&L for RCC M-30 Design Mix (using 20 mm graded stone aggregate) as in columns, pillars, piers, posts and struts complete all as specified and directed. | 3.5 | Cum | 7,000 ₹24,500 Lowest | 7,500 ₹26,250 | 7,500 ₹26,250 | 7,500 ₹26,250 | 7,900 ₹27,650 | 7,500 ₹26,250 |
| 5.00 | M&L for RCC M-30 Design Mix (using 20 mm graded stone aggregate) as in beams, cantilevers, bressummers, lintels over 1.5 m span complete all as specified and directed. | 1.5 | Cum | 7,500 ₹11,250 Lowest | 7,500 ₹11,250 Lowest | 7,500 ₹11,250 Lowest | 7,500 ₹11,250 Lowest | 8,000 ₹12,000 | 7,500 ₹11,250 Lowest |
| 6.00 | Use and waste of form work to flat sides of concrete foundation footing, bases of columns raft and raft beams sides and soffits of foundation and plinth beams and similar work vertical or to batter for fair finished surface of concrete complete all as specified and directed. | 6.75 | Sqm | 400 ₹2,700 Lowest | 425 ₹2,868.75 | 425 ₹2,868.75 | 425 ₹2,868.75 | 550 ₹3,712.5 | 600 ₹4,050 |
| 7.00 | Use and waste form work to sides of pillars, posts, struts, piers, columns and stanchions for fair finished surfaces of concrete complete all as specified and directed. | 26 | Sqm | 400 ₹10,400 Lowest | 400 ₹10,400 Lowest | 400 ₹10,400 Lowest | 400 ₹10,400 Lowest | 500 ₹13,000 | 400 ₹10,400 Lowest |
| 8.00 | Use and waste formwork to sides and soffits of floor or roof beams, beam haunchings, lintels including supports, etc. also splays between floors and beams, etc. for fair finished surfaces of concrete complete all as specified and directed. | 2.5 | Sqm | 400 ₹1,000 Lowest | 428 ₹1,070 | 430 ₹1,075 | 428 ₹1,070 | 500 ₹1,250 | 428 ₹1,070 |
| 9.00 | M&L for mild steel TMT bars 10 mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.90 mm dia or securing with clips complete all as specified and directed. | 465 | Kg | 110 ₹51,150 Lowest | 115 ₹53,475 | 120 ₹55,800 | 115 ₹53,475 | 120 ₹55,800 | 300 ₹1,39,500 |
| 10.00 | M&L for mild steel TMT bars 5 mm dia and over in stirrups, spacers and binders, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.90 mm dia or securing with clips complete all as specified and directed. | 141 | Kg | 110 ₹15,510 Lowest | 115 ₹16,215 | 115 ₹16,215 | 115 ₹16,215 | 120 ₹16,920 | 250 ₹35,250 |
Tender Value
₹40.5 L
EMD Value
₹80,920
Closing Date
11 Aug 2025, 6:00 pmClosed
GE GOMANTAK
GE Gomantak Vasco Da Gama Pin 403802
Provision of two in one storage space near P182 at NofraI Special repairs of building Bldg No P591 Badminton court at Naval Officers Institute and Special repairs of fire fighting pump houseP-02 at MO Goa under GE Gomantak Vasco
2025_MES_719991_1
8727/E8
Open Tender
Support/Maintenance Service
Item Rate
180 days
VASCO DA GAMA
As per tender docus
8 documents required · 8 mandatory
₹500
GE GOMANTAK
₹80,920
Yes
12 Sept 2025
12 Jul 2025
13 Aug 2025
12 Jul 2025
11 Aug 2025
28 Jul 2025
Amount
Excavation in trenches in soft/disintegrated rock, n exc 1.5 m wide and n exc 1.5m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sqm on plan and getting out complete all as specified and as directed.
M & L for plain cement concrete 1:4:8 type D-2 (using 40mm graded stone aggregate) as in foundation, filling & mass concrete complete all as specified and directed.
M&L for RCC M-30 Design mix (using 20 mm graded stone aggregate) as in footing, foundation beams, plinth beams, bases of columns etc. complete all as specified and directed.
M&L for RCC M-30 Design Mix (using 20 mm graded stone aggregate) as in columns, pillars, piers, posts and struts complete all as specified and directed.
M&L for RCC M-30 Design Mix (using 20 mm graded stone aggregate) as in beams, cantilevers, bressummers, lintels over 1.5 m span complete all as specified and directed.
Use and waste of form work to flat sides of concrete foundation footing, bases of columns raft and raft beams sides and soffits of foundation and plinth beams and similar work vertical or to batter for fair finished surface of concrete complete all as specified and directed.
Use and waste form work to sides of pillars, posts, struts, piers, columns and stanchions for fair finished surfaces of concrete complete all as specified and directed.
Use and waste formwork to sides and soffits of floor or roof beams, beam haunchings, lintels including supports, etc. also splays between floors and beams, etc. for fair finished surfaces of concrete complete all as specified and directed.
M&L for mild steel TMT bars 10 mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.90 mm dia or securing with clips complete all as specified and directed.
M&L for mild steel TMT bars 5 mm dia and over in stirrups, spacers and binders, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.90 mm dia or securing with clips complete all as specified and directed.
M&L for providing damp proof course 40 mm thick in cement concrete 1:2:4, type B-0 (using 12.5 mm graded stone aggregate) to horizontal or vertical surfaces mixed with water proofing compound as per manufacturere instructions including necessary formwork complete all as specified and directed. NOTE:- Water proofing compound shall be measured and paid seperately.
M&L for precast cement concrete block masonry, type C-1 (1:3:6) (20 mm graded aggregate) with solid blocks, exc 10 cm in width and setting in CM 1:6 complete all as specified and as directed.
Providing and applying 15 mm thick ready mix external sand faced cement plaster with neat cement rendering at all locations in two coats on masonry (except stone masonry) and concrete surfaces with and including mixing water proofing compound to the first coat of plaster as per manufacturers specification, racking out joints, hacking of concrete surface, finishing, curing, scaffolding etc complete all as specified & directed.
Providing and applying 10 mm thick ready mix external sand faced cement plaster with neat cement rendering at all locations in two coats on masonry (except stone masonry) and concrete surfaces with and including mixing water proofing compound to the first coat of plaster as per manufacturers specification, racking out joints, hacking of concrete surface, finishing, curing, scaffolding etc complete all as specified & directed.
Hardcore of broken stone or boulder gauge n. exc. 63 mm, deposited, spread & levelled in layers n.exc. 15 cm thick watered and rammed to a true surface complete all as specified and directed.
M&L for glazed ceramic coloured tiles of size 250 x 375 x 6-7 mm thick in vertical surface set and jointed in neat cement slurry and pointed in white or coloured cement to match the existing surface with & including rendering 10 mm thick in cement mortar 1:4 finished rough to fix tiles complete all as specified and directed.
M&L for cement concrete 1:4:8 type D-2 (using 40 mm graded stone aggregate) 75 mm thick as in sub base finishing the surface even and rough to receive floor complete all as specified and directed.
M&L for non skid ceramic coloured tiles 7 to 8 mm thick (square or rectangular) area of each tiles exceeding 0.06 Sqm but not exceeding 0.11 Sqm as in floor set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles laid over & including screed bed or bedding layer of mortar 15 mm thick in cement mortar 1:4 for laying floor finishes complete all as specified and directed.
M&L for applying one coat of alkali resistant primer on plastered surfaces of ceiling over 3mm thick putty and applying two coat of oil bound distemper including preparation of new surfaces complete all as specified and directed.
M&L mild steel work as hold fasts and similar small articles conforming to Fe-290, Gde E-165 complete all as specified and directed.
S&F powder coated (any colour and thickness of coating not less than 50 micron) sliding aluminium window/ ventilator with frame section 100 x 44 x 2 mm fixed with thrust bolts in wall by drilling (any number of leaf) comprising of following :- (a) Aluminium double shutter of glass and one shutter for wire mesh 44 x 44 x 2 mm top/bottom/side style. (b) Three track rail of section 92 x 25 x 1 mm suitable for smooth run of Sliding windows. (c) 02 Nos Roller for each shutter (d) Aluminium powder coated handle 150 mm long 1 No in each shutter (e) Tinted glass 4 mm thick (f) Aluminium anodised wire mesh of size 1.5 mm x 3 mm mesh, 20 Gauge thick (g) DG-104 10 mm thick Aluminium powder coated grill fixed with H section. NOTE:- On requirement/ non avalibility of above mentioned sections next higher section to match other sections will be provided by the contractor without any extra cost to the Govt.
S&F Solid PVC frame (single rebated) size 60 mm x 30 mm made out of solid PVC foam with homogeneous fine cellular structure having smooth outer integral skin with suitable metal stiffner and fixed with 100 x 8 sheet metal CSK screws complete all as specified and as shown on drawing. NOTE: Door frame shall be water proof, termite proof, elegant and should have excellent screws holding strength to fix hinges and hold doors properly for a long life.
S&F Factory made solid panel PVC door shutter 30mm thick (style) consisting of frame made out of MS tubes for top & bottom rails, MS frame shall be covered with heat moulded plain colour PVC 'C' channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; panelling of plain colour PVC sheet to be fitted in the MS frame welded/sealed to the stiles and rails with suitable PVC sheet beading, and jointed together with solvent cement complete all as specified and directed.
S&F aluminium powder coated (thickness or powder coating not less than 50 micron) frame and shutters for doors/windows/ventilators, sliding/ fixed/ openable type complete with necessary fittings such as two concealed lock for each window, roller, hinges etc. wheel etc. including necessary arrangements to receive 3/4 mm thick glass or wire mesh with aluminium channel beading & stainless steel screws complete all as specified and directed. Note : (a) The weight of rubber gasket beading will not be measured with the weight of aluminium shutters, glass will be measuerd and paid separately. (b) The rate quoted by the contractor shall also include necessary wheels for sliding shutters and hinges for side hung/top hung shutter as required at sight and concealed locks for windows. (c) The colour of powder coating shall be as approved by GE.
M&L for figured glass(frosted), 3 mm thick, pin head type and fixed rubber beading, aluminium strips in squares not exceeding 0.50 Sqm in each pane fixed in aluminium windows/ doors/ partition/ ventilators complete all as specified and directed. Note :- Aluminium glazing strip/ metal strip paid sepetately under respective item.
M&L for 4 mm thick sheet glass ordinary quality and fixed with oil putty or rubber beading, wooden/aluminium beads and provsion of glazing pins where required fixed in wooden/ aluminium/ steel windows/ doors/ partition/ ventilators complete all as specified and directed. Note :- Aluminium glazing strip/ metal strip paid sepetately under respective item.
S&F aluminium anodised barrel tower bolt of extruded section 150 mm long (ISI marked) and fixed complete all as specified and directed.
S&F 100 mm size mild steel butt hinges, ISI marked, medium weight, cold rolled and fixed with screws/welded to frame complete all as specified and directed.
S&F aluminium handles, cast type, anodised, ISI marked 150 mm size complete all as specified and directed.
S&F rolled mild steel in roof trusses(framed), trussed purlins, crane gantries, rails and fastenings, MS pipe for post and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc. conforming to Fe- 290(Gde E-165) complete all as specified and directed.
S&F Pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50 mm thick of any colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall, fixed with self tapping screws complete all as specified and directed.
M&L 4mm thick non asbestos fiber cement plain building boards fixed or laid/ inserted to timber/GI/Aluminium frame work in ceiling including complete all as specified and directed.
Dismantling boarding, any description, fixed in any position with nails complete all as specified and directed.
S&F powder coated aluminium snap grid frame work for false ceiling size of grid 605 x 605 mm, providing hangers 6 mm dia G.I (upto 1200 mm lenght) adjusting level fixed to roof slabs by means of ceiling cleats made out of G.I flat 40 x 3 mm size 60 mm long and expansion hold fastners 12.5 mm dia, 40 mm long and frame work shall be of 35mm x 38mm T runner of approved make complete all as specified and directed.
M&L for providing ceiling with 8 mm thick 100% solid WPC (wood polymer composite) sheet of required size comprising of virgin PVC resin of K value 57-60 (suspension grade), calcium carbonate and natural fibers (wood powders/ rice husk/ wheat husk and non toxic additives, made from extrusion process WPC foam sheet single extruded (inner) with having minimum density not less than 650 Kg/cbm, Minimum compressive strength of 50 N/mm2, moduls of elasticity 850 N/mm2 and resistance of spread of flame of class A category with Property of being Termite / borer free, water/ moisture proof and fire Retardant WPC complete all as directed. Note :- Material test Certificate and authentication should be compulsory provided by the manufacturing company.
Taking down cement or cement lime plaster on walls/ concrete/roof slab any description including racking out joints hacking for key, scrubbing down with water etc. and removing rubbish complete all as specified and directed.
Providing and applying 20 mm thick ready mix external sand faced cement plaster with neat cement rendering at all locations in two coats on masonry (except stone masonry) and concrete surfaces with and including mixing water proofing compound to the first coat of plaster as per manufacturers specification, racking out joints, hacking of concrete surface, finishing, curing, scaffolding etc complete all as specified & directed.
M&L for forming square grooves in plaster n. exc. 12 mm deep and n. exc. 15 mm on face complete all as specified and directed.
M&L for applying a coat of SmartCare Primero with dilution ratio of 1:1 with water maintain a coverage of 100 sq.ft/ltr cleaning off the dust, dirt etc. and filling cracks with smart crack filler mixed with cement in 1:3 on walls complete all as specified & directed.
M&L for preperation of new surface wall/ceilling by scrapping/ rubbing, applying two coat of advanced anti-algal weather proof 100% acrylic smooth emulsion with silicon additives, over a coat of fibre reinforced elastomeric liquid water proofing membrane (Asian paint damp proof + ultima suprema, exterior anti fungal paint or equivalent), including making proper surface by applying ready mix preparatory wall care putty wherever required complete all as manufacturers instructions and as directed. Note:- The application of paint shall be done by the authorized applicator of the company and also the dealer/company shall appoint a person to inspect and validate the application of emulsion in stage wise manner.
M&L for preperation of old surface wall/ceilling by scrapping/ rubbing, applying two coat of advanced anti-algal weather proof 100% acrylic smooth emulsion with silicon additives, over a coat of fibre reinforced elastomeric liquid water proofing membrane (Asian paint damp proof + ultima suprema, exterior anti fungal paint or equivalent), including making proper surface by applying ready mix preparatory wall care putty wherever required complete all as manufacturers instructions and as directed. Note:- The application of paint shall be done by the authorized applicator of the company and also the dealer/company shall appoint a person to inspect and validate the application of emulsion in stage wise manner.
Providing and applying 12 mm thick ready mix external sand faced cement plaster with neat cement rendering at all locations in two coats on masonry (except stone masonry) and concrete surfaces with and including mixing water proofing compound to the first coat of plaster as per manufacturers specification, racking out joints, hacking of concrete surface, finishing, curing, scaffolding etc complete all as specified & directed.
M&L for applying one coat of alkali resistant primer on plastered surfaces of wall over 3 mm thick wall care putty and applying two coat of oil bound distemper including preparation of new surfaces complete all as specified and directed.
M&L for applying one coat of alkali resistant primer on plastered surfaces of wall over 3 mm thick wall care putty and applying two coat of oil bound distemper including preparation of old surfaces complete all as specified and directed.
Demolition of un reinforced cement concrete of any description and in any position not otherwise specifically provided for complete all as specified and directed.
M&L for 75 mm thick cement concrete type C2 1:3:6 (using 40 mm stone graded crushed stone aggregate) as in plinth protection surface finished even and smooth without using extra cement including forming construction (dummy) joints 6 mm wide & 10 mm deep and filled with filler at an interval not exceeding 3 metre and at change of direction and necessary formwork complete all as specified and directed.
M&L for cement concrete 1:4:8 type D-2 (using 40 mm graded stone aggregate) 100 mm thick as in sub base finishing the surface even and rough to receive floor complete all as specified and directed.
M&L for fixing 60 mm thick factory made chamfered edge cement concrete paver block of M-35 grade with approved colour, design & pattern as in footparth, parks, lawns, drive ways or light traffic parking etc., of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over and including 50 mm thick compacted bed of fine sand, compacting and proper embedding/ laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand complete all as specified and directed.
Removing excavated material (Soils/Rock) to a distance exceeding 1.5 Km but not exceeding 5 Km and depositing where directed at a level n.exc. 1.5 m above the starting point complete all as specified and directed.
M&L for taking down eaves gutters and rainwater pipes (any sizee or pattern), including all fittings, heads, shoes, bends, swan-necks, etc.,including cleaning or refixing or removal to Store (measured overall as fixed along the centre line over fitting and accessories) complete all as specified and directed.
S&F PVC (SWR) pipe 110 mm bore, single socketed, in any length with rubber ring joints and jointed with approved adhesive and fixed to walls complete all as specified and directed.
Dismantling of plain or corrugated steel sheeting, any gauge, thickess including Nainital or similar pattern roofs covering complete all as specified and directed.
S&F 0.71 mm thick plain aluminium sheeting Alloy 31000 H4 as in ridges, hips, valley gutters, drips and straight flashing complete all as specified and directed.
S&F rolled mild steel sections as in main and cross beams, hip and jack rafters; purlins where connected to common rafters and running rails and guides for sliding doors; fixed with angle cleats or other connecting plates conforming to Fe-410-W (Gde-E-250) quality A complete all as specified and directed.
M&L for preparation of new or previously untreated steel surfaces exceeding 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer all as specified and directed.
M&L for rendering 5 mm thick on ceiling in cement mortar 1:4 including finishing the surface even and smooth without using extra cement complete all as specified and directed.
M&L for applying 3 mm thick putty and applying two coat of oil bound distemper including preparation of old surface of ceiling surfaces complete all as specified and directed.
Chipping off existing loose, damaged concrete from RCC members of all affected RCC Columns, beams, slabs and chajjas on external and internal facades etc beyond main r/f.(if required in the opinion of the consultant), carefully with chisel and hammer including relieving structural members such as column, beam and slabs of their superimposed load partially or fully by provision of adjustable steel props, frames etc. Providing and applying "Rusticide SS' Rust passivator or equivalent as specified in the Brand names to existing r/f bars including wire brushing of r/f, cleaning, washing of concrete etc complete as directed. Providing and applying two coats of rust preventor slurry made out of "Polyalk Fixoprime" or equivalent as specified in the brand names and cement in proportion 1:1.5 to exising r/f bars as directed complete. Providing and applying bonding coat of slurry made out of "Polyalk EP" or equivalent as specified in the brand names and cement in proportion 1:1 to concrete and r/f substrates complete as directed. Providing and applying 'Polyalk EP' or equivalent as specified in the brand names. Polymer modified cement mortar in required porportion (1:5:15) to RCC members including hand packing, curing and making the surface rough for plastering complete all as specified and directed.
M&L for jacketing around columns with Micro concrete (Molith-MC) M-40 including all lifts, shuttering, drilling holes and fixing shear anchor as per specifications complete all as specified and directed. NOTE:- Reinforcement shall be measured and paid separately.
S&F rolled mild steel in compound girders and stanchions, lattice girders, aerial masts, staging for water tanks and the like including caps, bases, splices etc. built up from two or more beam or channel sections or angles with plates, including all lattice bars, stiffners, gusset plates, etc. conforming to Fe-410W Gde- E-250 quality A complete all as specified and directed.
Excavating in post holes(or similar holes) each n.exc 0.5 cum in soft/disintegrated rock, getting out, returning, filling in, watering and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25cm and removing surplus soil to a distance n.exc 50m and making good surfaces complete all as specified and directed.
M & L for plain cement concrete 1:3:6 type C-2 (using 40mm graded stone aggregate) as in foundation, filling & mass concrete complete all as specified and directed.
Dismantling of loose portion of concrete from ceiling and S&F of wiremesh of weight 2.5 Kg/Sqm and applying 25 mm average thickness in CM(1:4) mixed with and including liquid WPC (complast 'X' as recommended by the manufacturer with guniting machine at a pressure not less than 5 kg/sqm finally rendering 10 mm thick plaster in CM (1:4) mixed with and including Liquid WPC (Complast 'X' 421 from M/s Fosroc and nitobound AR from M/S Fosroc or equivalent as approved by GE ) in the proportion recommended by the manufacturer complete all as specified and directed.
M&L for light shade vitrified ceramic tiles 10 mm thick(square/rectangular) polished, area of each tiles not exceeding 0.36 Sqm as in floor set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles laid over & including screed bed or bedding layer of mortar 15 mm thick in cement mortar 1:6 for laying floor finishes complete all as specified and directed.
Dismantling floor, hearth or wall tiling including cement mortar bedding (including backing), removing tiles and rubbish off the premises complete all as specified and directed.
Demolition of cement concrete unreinforced in ground floors and pavings n.exc. 15 Cm thickness (below or above ground level) complete all as specified and directed.
M&L For Exterior/ parking floor tiles heavy duty for light traffic, non skid, anti scratch, heavy grip vitreous/ semi vitreous coloured, unique design tiles of size 300 x 300 x 8 to 10 mm thick each as in floor, steps, risers, landing, set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles with & including screed bed or bedding layer of mortar 15 mm thick in cement mortar 1:4 for laying floor finishes complete all as specified and directed. Make:- Duracrete, Durato, RAK, Bell, H&R Johnson, Somany
Taking down existing roof treatment of any type with PCC beading, cleaning of roof top by brooming down with steel wire brush, scrapping down with steel scrapper and roughening surfaces of old roof and washing down with water to remove dust etc. complete all as directed. NOTE:- Debries shall be removed outside Defence land without any extra cost to the Govt. complete all as directed.
M&L for providing 10 mm thick ready mix cement plaster with water proofing compound over roof slab as per manufacturers specification, complete all as specified & directed.
M&L for laying water proofing treatment using 4mm thick APP modified membrane consisting five layers membrances with features as specified weighing not less than 3.50 kg per sqm reinforced with non woven polyester fiber @ 160 gm/Sqm laid over a coat of cold applied bituminous primer @ 0.40 kg/sqm by torching the membrance and sealing the over lap by 100 mm length side and 150 mm width side all as per manufacturer instructions including joints and changes in direction be curved with cement mortar 1:3 mixed with SBR latex @ 200 ml/bag of cement curved well before laying membrance complete all as specified and directed Note: (i) Irrespective of lap the net covered area will only be measured for payment. (ii) Rate is inclusive of APP membrane, SBR Latex etc.
Taking down Chowkats or frames with shutter (without taking off shutters from the frame) n. exc. 1.50 sqm each complete all as specified and directed.
Taking down Chowkats or frames with shutter (without taking off shutters from the frame) exc. 1.50 sqm and n. exc. 4.00 sqm each complete all as specified and directed.
M&L for forming jambs etc to opening, including cutting, toothing proper bonding into old work, also facing, jointing and pointing to match the existing work, new work built in CM 1:6 complete all as specified and directed.
S&F aluminium anodised wire mesh of size 1.5 mm x 3 mm mesh, 20 Gauge thick in doors/window shutters complete all as specified and directed.
S&F Deco-102 (10 mm thick), Anodised aluminium grill (anodised transparent or dyed to required shade according to IS 1868 with minimum anodic coating of grade AC 15 of approved design/ pattern with approved standard section and fixed to the existing window frame with CP brass/ stainless steel screw @ 200 mm centre to centre including cutting the grill to proper opening size for fixing and operation of handles and fixing approved anodised aluminium standard section around the opening all complete all as specified and directed.
M&L for providing factory made 25 mm thick 100% solid WPC (wood polymer composite) coloured laminated flush door shutter of required size comprising of virgin PVC resin of K value 57-60 (suspension grade), calcium carbonate and natural fibers (wood powders/ rice husk/ wheat husk (non toxic additives, made from extrusion process WPC foam single extruded (inner) with having minimum density not less than 650 Kg/cbm, having good screw holding capacity (Screw withdrawal strength of 2000 N (Face) & 1100 N (Edge), Minimum Compressive Strength of 50 N/mm2, modulus of elasticity 850 N/mm2 and resistance of spread of flame of class A category with Property of being Termite / borer free water / moisture proof and fire Retardant WPC to be Laminated with PVC foil of minimum 14 microns thick of approved design pasted on both faces of shutter and fixing with necessary full body threaded star headed counter sunk SS screw complete all as directed. Note :- Material test Certificate and authentication should be compulsory provided by the manufacturing company.
M&L for 2nd class hard wood plain, solid, straight chowkhats and frames, wrought, framed rebated on the solid, rounded or chamfered, put together with glue, pinned at joints complete all as specified and directed.
M&L for PCC 1:3:6 type C-1 (using 20 mm graded stone aggregate) as in hold fast etc. including necessary weathering, slightly rounded or chamfered angles and throating and necessary form work complete all as specified and directed.
M&L for 35 mm thick factory made, plain framed, panelled shutters (two panels), with lock rail and panels of 9 mm thick BWP commercial ply or 12 mm thick venered particle board with commercial veneering on both faces with rails and style of 2nd class hard wood. The size of rail and stile as per IS : 1003 (part I), kiln seasoned and chemically pressure treated complete all as specified and directed.
M&L for preparation of new or previously untreated wooden surfaces exceeding 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer all as specified and directed.
S&F in repair chromium plated brass shower roses 125mm dia with or without swival joints, including fixing to 15 mm dia pipe or union all as specified.
S&F in repair 20 mm dia brass chromium plated tubular towel rail, 60 cm long between flanges and hook fixed with rawl plug complete all as specified and directed.
S&F in repair vitreous china squatting pan Orissa pattern size 580 x 440 mm white with front or back inlet, integral foot rest and providing lime concrete bedding and connecting to flusing cistern complete all as specified and directed.
S&F vitreous china urinal half stall type, white excluding flushing cistern, flush pipe and waste pipe but including grating and union for discharge pipe complete including providing and fixing plugs, beding urinal agianst wall in cement mortar 1:2 securing urinal to plugs with and including 60mm long brass screws, pointing around urinal back in cement complete all as specified and directed.
S&F in repair vitreous china wash hand basin, white, flat back 550 x 400 mm excluding tap but including brackets 2 numbers including cutting for and pinning in ends of brackets, 32 mm CP brass waste coupling with long screwed shanks and fly-nuts, flange end bedded in red lead cement complete all as specified and directed.
S&F in repair 10 ltr PVC valveless, syphonic action type, flushing cistern, low level, white, with intel, ball valve, float and handle including brackets complete all as specified and directed
S&F PVC connection 600 mm long suitable for 15 mm GI pipe with two PTMT nuts & rubber washers complete all as specified and directed.
S&F in repair PVC flexible waste pipe 32/40 mm dia with socket minimum 900 mm long for WHB/ sink/ urinal complete all as specified and directed.
S&F in repair bib taps, cast copper alloy, fancy type, chromium plated with crutch or butterfly handles, screwed down, screwed for 15 mm bore GI pipe or for brass ferrule or to GI socket complete all as specified and directed.
S&F in repair stop valve/angle valve 15 mm nominal bore cast copper alloy, fancy type, chromium plated, screwed down high pressure with crutch or butterfly handle screwed both ends for iron pipes or for unions and fixed complete all as specified and directed.
S&F 75 mm dia PVC (SWR) floor trap, with stainless steel grating including jointing to waste pipe with solvent cement and fixed in cement concrete 1:2:4 type B1(using 20 mm graded stone aggregate) complete all as specified and directed.
S&F in repair PVC (SWR) pipe 110 mm bore, single socketed, in any length with rubber ring joints and jointed with approved adhesive and laid in trenches or in floors complete all as specified and directed.
S&F in repair PVC (SWR) pipe 75 mm bore, single socketed, in any length with rubber ring joints and jointed with approved adhesive and laid in trenches or in floors complete all as specified and directed.
S&F PVC (SWR) bend 110 mm dia, any radius fixed to pipe complete all as required and as directed.
S&F PVC (SWR) bend 75 mm dia, any radius fixed to pipe complete all as required and as directed.
S&F in repair soap dish, brass chromium plated, oval shaped of size 100 x 50mm (minimum), fixed to wall with PVC gully and CP screws complete all as specified and directed.
S&F 300 mm, mild steel ordinary rat tail rod pattern spring including roller and roller plate complete complete all as directed.
Dismantling water tank capacity exc. 500 ltr but n.exc. 1000 ltr complete all as specified and directed.
S&F in position rotational moulded polyethylene water storage tanks 1000 lts capacity (cylinderical vertical with closed top) hoisted and fixed in position all as specified in SSR Part I complete all as directed
S&F in repair ball valve 20 mm bore high presure of PTMT with epoxy coated aluminium rod and high density plastic ball screwed for iron pipe (minimum weight 210 grams) complete all as specified and directed.
Taking up or down existing GI tubing and connections, including making good the disturbed surface for 20 mm dia pipes complete all as specified and directed.
Taking up or down existing GI tubing and connections, including making good the disturbed surface for 25 mm dia pipes complete all as specified and directed.
Supply, fixing, laying & testing CPVC pipes 20 mm outer dia SDR 11 including Plain CPVC SDR 11 fittings laid in trenches complete all as specified and directed.
Supply, fixing, laying & testing CPVC pipes 25 mm outer dia SDR 11 including Plain CPVC SDR 11 fittings laid in trenches complete all as specified and directed.
S&F 20 mm dia gun metal globe or gate valve with iron wheel head screwed both ends and for iron pipe & fixed complete all as specified and directed. .
Removing excavated material (Soils/Rock) to a distance exceeding 1.5 Km but not exceeding 5 Km and depositing where directed at a level n.exc. 1.5 m above the starting point complete all as specified and directed.
Dismantling wrought iron or mild steel work of any description complete all as specified and directed.
Taking down copper/ aluminium point wiring (light, fan, socket or power) complete including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fittings etc. removing materials to store for keeping in safe custody or for taking credit and making good disturbed surfaces of walls, floors etc. to match the existing complete all as specified and directed. NOTE: Credit for this items shall be made as per conditions separately.
M&L for point wiring complete for one light/ fan/ exhaust fan point controlled by one, one way 5/6 Amp switch with PVC (FRLS) insulated unsheathed multistranded copper conductor of size 1.50 sqmm nominal cross sectional area single core drawn in and including minimum 20 mm dia 'medium grade' PVC conduit ISI marked concealed in wall and fittings and modular metal flush box, modular white cover plate with frame, blanking plate and making good to the disturbed surfaces to match the existing complete all as specified and directed including 1.50 sqmm nominal cross sectional area PVC(FRLS) insulated unsheathed multistranded copper conductor green as earth wire connected to earth dolly with all accessories including making good disturbed surface to match the existing surface complete all as specified and directed. Note- (i) Rates include the cost of blanking plate, modular plate, modular boxes and covers of suitable modules as required at site. (ii) Modular box, plate and cover shall be of same make as of switch//socket/regulator.
All as per item No. 110 above but for one 5 pin 5/6 Amp socket outlet point on same board
All as per item No. 110 above but for one 5 pin 5/6 Amp socket outlet point on an independent board.
All as per Item No 110 above but for one 6 pin 15/16 amps socket outlet point on an independent board with FRLS cables of size 4 Sqmm and green colour earth cable of size 4 Sqmm.
S&F modular type switch one way 6 Amps, 230 Volt, 1 Module complete all as specified and directed.
S&F modular type switch one way 16 Amps, 230 Volt, 1 Module complete all as specified and directed.
S&F modular type socket one way 6 Amps, 2/3 pin, 230 Volt, 2 Module complete all as specified and directed.
S&F modular type socket one way 6/16 Amps, 2/3 pin, 230 Volt, 2 Module complete all as specified and directed.
S&F ceiling rose, two or three terminal, surface bakelite 65 x 50 mm complete all as specified and directed.
S&F modular type fan regulator, electronic step type, 120 W, 2 Module complete all as specified and directed.
S&F in replacement MCB single pole 240 volts, 'C' curve of rating from 16 to 32 amps, with rupturing capacity 10 KA, including providing thimble for out going cables complete all as specified and directed.
S&F MCB single pole 240 volts, 'C' curve of rating from 16 to 32 amps, with rupturing capacity 10 KA, including providing thimble for out going cables complete all as specified and directed.
S&F MCB SPN 240 volts, 'C' curve of rating 32 Amps, with rupturing capacity 10 KA, including providing thimble for out going cables complete all as specified and directed.
S&F in replacement MCB tripple pole(TP) 415 volts, 'C' curve of rating 63 Amps, with rupturing capacity 10 KA, including providing thimble for out going cables complete all as specified and directed.
S&F in replacement sheet metal enclosure MCCB distribution board, double door with IP-43 protection TPN, 415 Volts, 8 way, Vertical type, including suitable size copper bus bar and metal door, epoxy powder coated, factory made complete without MCB and with enclosure blank plates for unused way fixed flush in wall including chases wall for fixing DB and making good distributed wall surfaces complete all as specified and directed.
S&F sheet metal enclosure MCB distribution board, double door with IP-43 protection single pole and neutral 240 volts, 8 way, including suitable size copper bus bar and metal door, epoxy powder coated, factory made complete without MCB and with enclosure blank plates for unused way fixed flush in wall including chases wall for fixing DB and making good distributed wall surfaces complete all as specified and directed.
S&F in repair sub main wiring with two single core PVC insulated (FRLS) unsheathed multistranded copper conductor of size 4 Sqmm nominal cross sectional area and one run of 4 sqmm nominal cross sectional area PVC insulated (FRLS) unsheathed multistranded copper conductor green colour as continuous earth wire drawn in and including not less than 32 mm PVC conduit and fittings concealed in wall/ roof/ floors/ ceiling etc. including cutting chases to walls for laying conduit wherever required and making good the disturbed wall surfaces to match with existing specification complete all as specified and directed. NOTE:- One unit length shall measured as two run of main wire, one run of earth wire and one run of PVC conduit
S&F sub main wiring with two single core PVC insulated (FRLS) unsheathed multistranded copper conductor of size 10 Sqmm nominal cross sectional area and one run of 10 sqmm nominal cross sectional area PVC insulated (FRLS) unsheathed multistranded copper conductor green colour as continuous earth wire drawn in and including not less than 32 mm PVC conduit and fittings fixed on wall/ roof/ floors/ ceiling etc. including cutting chases to walls for laying conduit wherever required and making good the disturbed wall surfaces to match with existing specification complete all as specified and directed. NOTE:- One unit length shall measured as two run of main wire, one run of earth wire and one run of PVC conduit
S&F LED tube light fitting surface and wall mounted batten Aluminium body with 22/20 watts LED having minimum 100 lumens/watts and with integrated electronic driver complete all as specified and directed. Make: Philips cat No-BN021CLED22S PSU CW GR/ Crompton cat no-CCS-103-20-65-SL-DP-NWH/ Halonix HLB-03-20-CW-AL-SQ.
S&F in replacement existing U/S light fitting with LED tube light fitting surface and wall mounted batten Aluminium body with 22/20 watts LED having minimum 100 lumens/watts and with integrated electronic driver complete all as specified and directed. Make: Philips cat No-BN021CLED22S PSU CW GR/ Crompton cat no-CCS-103-20-65-SL-DP-NWH/ Halonix HLB-03-20-CW-AL-SQ.
S&F brushless direct current (BLDC) ceiling fan 1400 mm sweep with service value 6.00 BEE, 5 star rating complete with blades and other accessories, single phase, 230 V including 1 m long down rod and making connection with sheathed 3 core cable of size 0.75 Sqmm flexible copper conductor wire complete all as specified and directed. Make : Havells cat No- FHCNF5SWHT56/Orient model Hector 500/ Bajaj Model- ENERGOS 28(SKU Code 251100EE)
S&F in repair brushless direct current (BLDC) ceiling fan 1400 mm sweep with service value 6.00 BEE, 5 star rating complete with blades and other accessories, single phase, 230 V including 1 m long down rod and making connection with sheathed 3 core cable of size 0.75 Sqmm flexible copper conductor wire complete all as specified and directed. NOTE:- Old exhaust fan will be deposited to MES store yard. Make : Havells cat No- FHCNF5SWHT56/Orient model Hector 500/ Bajaj Model- ENERGOS 28(SKU Code 251100EE)
S&F wall mounted fan 400 mm sweep (air circulating), single phase, 230 V complete all as specified and directed. Make : Bajaj cat no-Esteem400mm(SKU code 250542)/Havells cat no-Accelero HS grey(FHWACHSWGR16) /Orient 44 Crystal white
S&F in replacement exhaust fan (Metal body) of 300 mm sweep, AC single phase 230/240 volts, 1400 RPM, heavy duty complete including making electric connection with PVC insulated three core 1.5 Sqmm copper cable from ceiling rose to exhaust fan, making hole in wall of suitable size, grouting anchor bolts/fastners and making good to disturbed surfaces to match the existing complete all as specified and directed. NOTE:- Old exhaust fan will be deposited to MES store yard. Make : Orient Ind heavy duty 1400RPM/ Havells Turbo force 1P(FHEHDSPDB120) /Bajaj Supreme plus Ind fan
MS&F in replacement of LED 90 W street light made up of pressure die cast aluminium housing with high power LED as lighting source and lens embedded PC cover having top opening separately including driver compartment with IP66 protection including making connections with PVC insulated and sheathed three core multi stranded aluminium conductor cable of size 1.5 Sqmm complete all as specified and directed. Make- Shakti Cat no: SZPSLPM090/ Havells cat no: ENDURAOMINI PLUSSL90WLED757SASYTOPC/ Halonix Cat no: HLSLD-01-90-CWDL-R.
M&L removing existing earthing and new earthing complete with galvanised steel plate electrode 600mm x 600mm x 6mm thick buried directly in ground (earth pit not less than 2.25 Mts deep below ground level with top edge of the plate not less than 1.50 Mtrs below ground level connected to glavanised iron Wire 4.0 mm dia by means of bolts, nuts check nuts and washers of galvanised iron or steel connected to earthing test point all as specified incl 15 mm GI tubing medium grade and necessary fitting for protection of GI wire incl laying of charcoal dust and common salt in alternate layer, PCC Pit (1:3:6) type C-1 using 20 mm graded stone aggregate, RCC cover 40mm thick (1:2:4) type B-0 using 12.5 mm graded stone aggregate reinforced with 6 mm dia round bar @ 75 mm C/C both ways with MS handle 8 mm dia, plastering 15 mm thick CM (1:6) externally upto 150mm below ground level, GI funnel with 20mm dia medium grade GI pipe for watering and wire mesh incl. excavation and earth work and disposal of surplus soil complete all as specified and shown on electrical plate No. 3 of SSR Part (2009) and connected to earth test point incl testing complete all as specified an directed. Note:- The unit rate includes the cost of GI pipe medium grade for protection of earth wire and 4mm dia earh lead wire upto 7.5 M.
M&L for providing earthing complete with galvanised steel plate electrode 600 mm x 600mm x 6mm thick buried directly in ground (earth pit not less than 2.25 Mts deep below ground level with top edge of the plate not less than 1.50 Mtrs below ground level connected to glavanised iron strip 25 x 4 mm by means of bolts, nuts check nuts and washers of galvanised iron or steel connected to earthing test point all as specified incl GI tubing medium grade and necessary fitting for protection of GI wire incl laying of charcoal dust and common salt in alternate layer, PCC Pit (1:3:6) type C-1 using 20 mm graded stone aggregate, RCC cover 40mm thick (1:2:4) type B-0 using 12.5 mm graded stone aggregate reinforced with 6 mm dia round bar @ 75 mm C/C both ways with MS handle 8 mm dia, plastering 15 mm thick CM (1:6) externally upto 150mm below ground level, GI funnel with 20mm dia medium grade GI pipe for watering and wire mesh incl. excavation and earth work and disposal of surplus soil complete all as specified and shown on electrical plate No 3 of SSR Part (2009) and connected to earth test point incl testing complete all as specified an directed. Note:- The unit rate includes the cost of GI pipe medium grade for protection of earth wire and earth strip upto 7.5 M.
S&L in replacement XLPE LT UG cable PVC insulated, bedded armoured heavy duty electric cable 1100 volts grade with aluminum conductor of 95 Sqmm 3.5 core including gland, lugs etc. laid in trenches or fixed on wall/floor/poles complete all as specified and directed.
Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5 m deep in hard/dense soil for foundation, etc. or for laying of pipe line/ cable etc. n exc 10 sqm on plan and getting out complete all as specified and as directed.
Returning filling in including spreading watering and well raming in layer excedding 25 cm each in any type of soil/rock complete all as specified and directed.
Removing excavated material (Soils/rock) to a distance not exceeding 50 m and depositing where directed at a level n.exc. 1.5 m above the starting point complete all as specified and directed.
Supply & laying double walled corrugated (DWC) HDPE full rounded pipe conforming to IS 16205 Pt-24 of approved colour complete with fittings for cable protection of size 50 mm inner dia and 63 mm outer dia complete all as directed.
S&F in replacement existing U/S light fitting with LED tube light fitting surface and wall mounted batten Aluminium body with 40 watts LED having minimum 100 lumens/watts and with integrated electronic driver complete all as specified and directed.
S&F exhaust fan (metal body) of 450 mm sweep, heavy duty, AC single phase 230/240 volts, four blades, 1400 RPM including frame, louvers of suitable size and making hole in brick/concrete wall, grouting anchor bolts/fastners and making good to disturbed surfaces to match the existing complete including making electric connection with PVC insulated three core 1.5 Sqmm copper cable from ceiling rose to exhaust fan, complete all as specified and directed.
M&L for LED flood light fitting 350 Watts, IP 66, having pressure die cast aluminium alloy housing with heat resistant toughned glass with individual LED lenses, having surge protection device 10 KV and Driver shall be IP-67 for water protection, including making connections with PVC insulated and sheathed three core multi stranded alumn conductor cable of size 2.5 Sqmm complete all as specified and directed.
Leela Enterprises (BID ID -3379177)
JINTECH (BID ID -3381651)
M/S jvsr constructions (BID ID -3374363)
STAR FABRICATION (BID ID -3381520)
M/S G.N.POWAR (BID ID -3381910)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .