Loading…
Loading…
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance | Admitted-Finance |
| 2 | Admitted-Finance 19 C CUDDALORE MAIN ROAD PEDDANAICKENPALAYAM PO TK SALEM DIST PIN 636 109 | SALEM | SALEM | TAMIL NADU | 636109 | Admitted-Finance |
| 3 | Admitted-Finance NO 29 1 YADAV STREET KARALAPAKKAM THIRUVALLUR DIST CHENNAI 602 024 | CHENNAI | THIRUVALLUR | TAMIL NADU | 602024 | Admitted-Finance |
| 4 | Admitted-Finance | Admitted-Finance |
Tender Value
₹10.0 L
EMD Value
₹20,000
Closing Date
28 Oct 2022, 6:00 pmClosed
AGE I RD AVADI
AGE I RD AVADI CHENNAI 54
REPAIRS TO SANITARY FITTINGS, PLUMBING WORKS AND OTHER CONNECTED WORKS IN TECHNICAL AREA AT CVRDE AVADI
2022_MES_555652_1
8512/E8
Open Tender
Civil Works
Item Rate
240 days
CVRDE Avadi
REPAIRS TO SANITARY FITTINGS, PLUMBING WORKS AND OTHER CONNECTED WORKS IN TECHNICAL AREA AT CVRDE AVADI
8 documents required · 8 mandatory
₹500
AGE I RD AVADI
₹20,000
Yes
2 Nov 2022
3 Oct 2022
1 Nov 2022
3 Oct 2022
28 Oct 2022
14 Oct 2022
3 Oct 2022 - 14 Oct 2022
Amount
Notes for BOQ items:- (i) Contractor is required to deploy the Tradesman & helper daily (except holiday & Sunday) as under:- (a) One Plumber with One helper for all Plumbing related items including sanitary fittings and plumbing works of Sch ‘A’. All the trandesman shall be available at MES service centre at Technical area from 0830 Hours to 1630 Hours on all days. The rates quoted by contractor shall deemed to be include this aspect. In case, if the contractor fails to employ the above persons, a recovery of Rs 700/- per tradesman per day and Rs 400/- per helper per day will be deducted from the payments due to him. Contractor shall produce attendance register of tradesman & helper at the time of RAR payment duly signed by AGE. (ii) Attendance register alongwith details of complaint to monitor the arrival and departure of tradesman shall be maintained by JE-in-Charge and signed by the contractor on daily basis. (iii) The tradesman employed by the contractor shall have experience in their trades. The contactor will get the names of tradesman approved from Engr-in-Charge. The accepting officer reserves the right to reject the employment of such person forthwith. No claim what-so ever be entertained on this regard.
Dismantling PVC Tanks of capacity 250 Ltrs and 500 Ltrs and sold to contrator through schedule of credit complete all as specified and directed by Engineer-in-Charge.
Dismantling PVC Tanks of capacity 500 Ltrs and 1000 Ltrs and sold to contrator through schedule of credit complete all as specified and directed by Engineer-in-Charge.
S&F Roatation moulded polythene water storage tank 500 ltrs capacity (cylindrical vertical with closed top) hoisted and fixed in position complete all as specified and directed by Engineer-in-Charge.
S&F Roatation moulded polythene water storage tank 1000 ltrs capacity (cylindrical vertical with closed top) hoisted and fixed in position complete all as specified and directed by Engineer-in-Charge.
S&F in repair low density 32mm dia polyethylene pipes (LDPE) of pressure rating 6 kgf/cm2 fixed to WHB/urinal waste pipes complete all as specified and directed by Engineer-in-Charge.
S&F Ball valves high pressure of PTMT with epoxy coated aluminium rod & high density plastic ball screwed for 20mm dia bore iron pipe and fixed in repair complete all as specified and directed by Engineer-in-Charge. Note: Minimum weight 210 gms
Cleaning and removing all scales and dirt etc from Exc 250 liters capacity & n. exc 500 litres tanks and from mouth of circulating pipes of tanks and cleaned with bleaching powder complete all as specified and as directed by the Engineer-in-Charge.
Cleaning and removing all scales and dirt etc from Exc 500 liters capacity & n. exc 1000 litres tanks and from mouth of circulating pipes of tanks and cleaned with bleaching powder complete all as specified and as directed by the Engineer-in-Charge.
Cleaning and removing all scales and dirt etc from Exc 1000 liters capacity & n. exc 2000 litres tanks and from mouth of circulating pipes of tanks and cleaned with bleaching powder complete all as specified and as directed by the Engineer-in-Charge. Note for item No. 8 to 10: The debries will be removed form building and dumped as ordered.
Taking down or up old steel tubing for following dia bore galvanized including all connections all as specified and directed by Engineer-in-Charge.
(a) Bore of pipe in 15 mm.
(b) Bore of pipe in 20 mm.
(c) Bore of pipe in 25 mm
S&F refixing of old Galvanized steel water tubing for following dia bore, medium grade including provision of all fittings such as bends, tees, elbows, reducers, unions, plugs, sockets etc., fixed complete to walls and ceilings all as specified and as directed by the Engineer-in-Charge.
(a) Bore of pipe in 15 mm.
(b) Bore of pipe in 20 mm.
(c) Bore of pipe in 25 mm
S & F Galvanized steel water tubing for following dia bore, medium grade including provision of all fittings such as bends, tees, elbows, reducers, unions, plugs, sockets etc., fixed complete to walls and ceilings all as specified and as directed by the Engineer-in-Charge.
(a) Bore of pipe in 15 mm.
(b) Bore of pipe in 20 mm.
(c) Bore of pipe in 25 mm
S & F in repair cast copper alloy stop cock / angle cock chromium plated fancy type screwed down, high pressure screwed ends for 15mm dia bore pipe or for unions and all complete all as specified and directed by Engineer-in-Charge.
S&F in repair brass pillar taps 'Fancy type" cast copper alloy with capstan heads chromium plated screwed down high pressure with or without lettered hot or cold with long screwed shanks and flynuts screwed for 15mm dia bore iron pipe complete all as specified and directed by Engineer-in-Charge.
S & F in repair for Chromium plated brass bib tap cast copper alloy, fancy type, screwed down, screwed for 15mm dia bore iron pipe and all complete all as specified and directed by Engineer-in-Charge.
S&F in repair PTMT bib tap long body standard of any colour screwed for 15 mm dia bore iron pipe and fixed (Min weght 15 mm-90 gms) complete all as specified and directed by Engineer-in-Charge.
S&F CP brass shower rose 125mm size for 15mm dia bore and fixed in repairs complete all as specified and directed by Engineer-in-Charge.
S&F in repair plastic water closet seat cover, white colour, closed pattern with, flat bottom and cover and mild steel chromoum plated or aluminised hinging device complete all as specified and directed by Engineer-in-Charge.
M&L PVC(SWR) multi floor trap plain with grating lincluding jointing with solvent cement 75mm dia and fixed in repair complete all as specified and directed by Engineer-in-Charge.
S&F in repair PVC connection 15mm size with PTMT nuts of length 450mm long complete all as specified and directed by Engineer-in-Charge.
S&F in repair Waste fitting brass chromiuam plated for glazed ware WHB with 32mm dia complete all as specified and directed by Engineer-in-Charge.
S&F Tubular towel rail 20mm dia D type 60cm long between flanges brass chromium plated and fixed in repair complete all as specified and directed by Engineer-in-Charge.
S&F vitreous china squating pan "ORISSA' pattern or size 550 x 440mm white with integeral foot rest etc (Excluding flushing cistern and flush pipe) complete including trap set in cement motar & provision of lime concrete bedding and making good to floor, fixed in repairs complete all as specified and directed by Engineer-in-Charge.
S&F vitreous china wash down water closet (pedestal pattern) white including connecting to trap and to flushing pipe anti syphonage pipe etc incl seat cover complete set in concrete flush pipe to closet including all joints and making good floor and wall, fixed in repairs complete all as specified and directed by Engineer-in-Charge.
S&F PVC flushing cistern 10 ltrs and flush pipe syphonic action type low level with inlet ball valve, float and handle including brackets of approved, fixed in repairs complete all as specified and directed by Engineer-in-Charge.
S&F Chromium plated cast copper alloy health facuet for 15mm dia incl telephonic pipe & holder fixed in repairs complete all as specified and directed by Engineer-in-Charge. (Make : Parryware T9940A1 Slimline with SS Hose & Hook or equivalent)
Supply and fix in repair vitreous China wash basin, angle back, size 550x400mm white, excluding taps but including brackets, cutting for and finning in ends of brackets or erecting stand and 32 mm waste fitting, brass, chromium plated for glazed ware WHB with long screwed shanks and fly nuts, flange end bedded in red lead cement and other end fixed and waste pipe all as specified and as directed by the Engineer-in-Charge.
S&F Vitreous China Urinal, white of size 250 X 330X 460 (excluding flushing cistern, flush pipe and waste pipe) including bracket & speader and waste coupling fixed in repair complete all as specified and directed by Engineer-in-Charge. (Make Parryware, Niagara N C0579 (250 x 330 x 460mm) & E8113 Spreader)
S&F Vitreous China Urinal partition white of size 310X 770 fixed in repair complete all as specified and directed by Engineer-in-Charge.
Taking down PVC SWR / Drain pipe of any type, size and length including making good disturbed surface of wall complete all as specified and as directed by the Engineer-in-Charge.
S&F PVC SWR pipe 75 mm dia bore single socketed in any length with rubber ring joints fixed to wall complete all as specified and as directed by the Engineer-in-Charge.
S&F PVC SWR pipe 110 mm dia bore single socketed in any length with rubber ring joints fixed to wall complete all as specified and as directed by the Engineer-in-Charge.
M&L PVC(SWR) bends in 75mm dia complete all as specified and as directed by the Engineer-in-Charge.
M&L PVC(SWR) bends in 110mm dia complete all as specified and as directed by the Engineer-in-Charge.
PVC (SWR) junction singleT 75 mm dia complete all as specified and as directed by the Engineer-in-Charge.
PVC (SWR) junction singleT 110 mm dia complete all as specified and as directed by the Engineer-in-Charge.
Taking down cement plaster on brick walls including racking out joints, hacking for key scrubbing down with water etc. complete all as specified and as directed by the Engineer-in-Charge.
Rendering 15mm thick in fair faces of brick work or concrete surfaces in CM 1:4 finished even and smooth with out using extra cement but using water proofing compound complete all as specified and as directed by the Engineer-in-Charge. Note: Water profing compound will be measured ans paid separately.
Supply only water proofing compound
Preparation of newly plastered surfaces of walls and applying two coats of oil bound distemper including one coat of chalk whiting primer complete all as specified and as directed by the Engineer-in-Charge.
Dismantling floor, hearth or wall tilling including cement mortar (but not backing) including removing the debries from the site complete all as specified and as directed by the Engineer-in-Charge.
M&L Non skid ceramic coloured tiles 7 to 8mm thick area of each tiles exc 0.06 Sqm but not exc 0.11 Sqm in floors etc and jointed in neat cement slurry including 15 mm thick screed in cement mortar (1:6) pointed in white cement with pigment to match the colour of tiles complete all as specified and as directed by the Engineer-in-Charge.
M&L glazed ceramic coloured 300x450x7 mm thick on vertical surface such as skirting / dados set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade over & including rendering 10 mm thick in cement mortar (1:4) complete all as specified and as directed by the Engineer-in-Charge.
K Kumar Construction
SathguruSaiEnterprises
S.T.S.CONSTRUCTIONS AGENCIES
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .