6 Aug 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE Jaipur
Garrison Engineer, Military Engineer Services, Khatipura road, Jaipur 302012
CERTAIN LBW WORK UNDER ZONE-II AND E/M AREA AT JAIPUR MIL STN
2021_MES_458803_1
GE/J-10/2021-22
Open Tender
Civil Works
Item Rate
180 days
Jaipur
As per NIT
5 documents required · 5 mandatory
₹500
GE Jaipur
₹30,660
Yes
9 Oct 2021
10 Jul 2021
8 Aug 2021
10 Jul 2021
6 Aug 2021
24 Jul 2021
10 Jul 2021 - 23 Jul 2021
60 days
Amount
Excavation over areas n. exc 3.00 mtr deep and getting out in soft loose soil complete all as specified and directed by Engineer-in-Charge.
Surface excavation not exceeding 30 cm deep and averaging 15 cm deep and getting out in soft/loose soil complete all as specified and directed by Engineer-in-Charge.
M&L PCC 1:4:8 type D-2 using 40 mm graded stone aggregate as in foundations filling and mass concrete complete all as specified and directed by Engineer-in-Charge.
Excavating in trenches, n exc 1.5m wide and n exc 1.5m in depth; for foundation etc. or for shafts, wells, esspits, manholes, pier holes, etc. n exc 10sq m on plan and n exc 1.5m in depth and getting Out in soft loose soil complete all as specified and directed by Engineer-in-Charge.
M&L Reinforced cement concrete M-25 (designmix) in:- Foundations, including rafts, footings, foundation, beams; plinth beams; basesfor columns, etc. basementslabs, under-reamed pilesand mass concrete complete all as specified and directed by Engineer-in-Charge.
M&L Reinforced cement concrete M-25 (designmix) in Columns, pillars, piers posts and struts complete all as specified and directed by Engineer-in-Charge.
M&L for RCC M-25 (Design Mix) with 20mm graded aggregates for slabs supported on walls, beams and columns in floors roofs , landings , balconies, canopies deck slab , in selvese and roof beams or similar works etc complete all as specified and directed by Engineer-in-Charge.
M&L for cement concrete design mix M-25 (20 mm graded aggregate) as in /lintel/ roof beams, cantileveres, bressummers, lintels over 1.50 mtr span and all other similar works complete all as specified and directed by Engineer-in-Charge.
M & L mild steel TMT bars 10mm dia and over,cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mmdia or securing with clips complete all as specified and directed by Engineer-in-Charge.
Ditto but 5mm dia and over upto and including 10mm dia for links , stirrups, spacers and binders complete all as specified and directed by Engineer-in-Charge.
M&L Use and waste of formwork to rough finished flat surfaces of concrete foundations, footings , bases of coulmns, rafts and raft beams, sides and soffits (if any) of foundation and plinth beams ; and other similar works; vertica or to batter complete all as specified and directed by Engineer-in-Charge.
M&L Use and waste of formwork to rough finished concrete surfaces of sides of square, rectangular or polygonal pillars posts, struts, piers, coulmns and stanchions complete all as specified and directed by Engineer-in-Charge.
M&L for formwork to sides and soffits of suspended slabs such as roof slab, floor slabs landing horizontal or slopping and similar workks thikness n.exc 200mm including neccesarry sufficient supports as directed by Engg-in-Charge etc for flat and rough finished surfaces of concrete etc complete all as specified and directed by Engineer-in-Charge.
Use and waste of formwork to soffits of floor or , beam haunching ,grider, bressumber, lintels,cantilever ,sleves including supports ,over hang etc also splay between floor and beams to rough finish surface of concrete flat complete all as specified and directed by Engineer-in-Charge.
Demolition of brickwork or stone/boulder masonry, built in lime mortar including all quions, arches, pillars etc, but excluding ashlar facings, dressed stonework and precast concrete articles complete all as specified and directed by Engineer-in-Charge.
M&L brickwork with subclass `B' bricks, straight or curved on plan exc 6m mean radius, built in cement mortar (1:6) complete all as specified and directed by Engineer-in-Charge.
M&L for rendering 15mm thick on fair face of brick masonry walls in CM 1:4mixed with WPC on walls finished even and fair without using extra cement. Note: WPC shall be measured & paid separately complete all as specified and directed by Engineer-in-Charge.
M & L for 15 mm thick cement plaster in CM (1:6) on brick work/ RCC wall and finish the surface fair and even without using extra cement complete all as specified and directed by Engineer-in-Charge.
M&L for Rendering 10 mm thick on ceiling in CM(1:3) finished even and smooth without using extra cement complete all as specified and directed by Engineer-in-Charge.
Material and labour rendering 15mm thick cement plaster in CM 1:4 on other than fair faces of brick/concrete work surfaces in two layer 10mm each layer and top layer mixed with integral water proofing compound all as per manufacturer's instruction including all necessary scafolding arrangments of any hieght and as specified. Make:Pidilite/Sika for WPC Note: (i) WPC shall be measured and paid for separately as 'Supply only'. (ii) WPC to be mixed @200ml per 50 Kg bag of cement all as manufacturers instruction.
Supply only liquid water proofing compound.
M&L for preparation of new surfaces and applying two coats of oil bound distemper over a coat of water based primer over 3mm thick (average) wall care putty applied in two coats including rubbing with siutable sand paper complete all as specified and directed by Engineer-in-Charge.
M&L for preparation of new plastered surfaces of walls and applying two coats of cement based paint over a coat of primer and wall putty complete all as specified and directed by Engineer-in-Charge.
M&L for preparing new plastered surfaces of walls and applying two coat of cement based paint complete all as specified and directed by Engineer-in-Charge.
M&L for preparing new plastered ceiling surfaces and applying three coat of white wash complete all as specified and directed by Engineer-in-Charge.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm in soft/ integrated rocks/ soil. Etc all as specified and directed complete all as specified and directed by Engineer-in-Charge.
Removing excavated material n exc. 50m and depositing where directed at a level n exc. 1.5 m above the starting point complete all as specified and directed by Engineer-in-Charge.
M&L PCC 1:2:4 type B0 using12.5 mm graded stone aggregeate for coping etc surface finished even and smooth without using extra cement complete all as specified and directed by Engineer-in-Charge.
S & F Framed work as in doors or gates of angle or other section with gusset plates, rails, races, etc., complete, drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering running rails and guides) and hanging; also fastening and fixing complete( incl ornamental designs) complete all as specified and directed by Engineer-in-Charge.
Preparation of new surface of steel and iron and applying two coat of synthetic enamel paint over a coat of redoxide zinc chromate primer complete all as specified and directed by Engineer-in-Charge.
M&L jaipur tradition dome statue made of karauli stone upto one mtr height and dia upto 0.75mtr fixing /grouting properly on the main gate column complete all as specified and directed by Engineer-in-Charge.
S&F brass letters of approx height 30 cm with standard width and thickness as per manufacturer decoration/design complete all as specified and directed by Engineer-in-Charge.
M&L Granite (of any type) tiles 20mm thick machine cut, bedded and jointed with grey cement slurry and pointed with white cement with admixure of pigment to match the shade of granite stone including cutting grinding and polishing , laid over an including 15 mm thick acreed bed in cm 1:6 including securing of granite stone over all with steel studs spacing note more than 1.00 m complete all as specified and directed by Engineer-in-Charge.
M & L for fibre glass reinforced translucent sheeting 2mm thick woth two corrugation side lap fixed with coatch screws and washeras in roof wall etc.
Rounding to edges of stone slabs (Kota / Granite) one edges such as in steps, cooking platform and other similar situations all as specified
M&L for treating the bottom and sides of excavation at the rate of 5 litres of emulsion per square metre of surface area
M&L for treating the backfill in contact with foundation at the rate of 7.5 litres of emulsion per square metre of vertical surface (Area of the substructure in contact with backfill to be measured)
M&L for treating the top surface of filled earth at the rate of 5 litres of emulsion per square metre of surface
M&L for treating the soil under plinth protection at the rate of 5 litres of emulsion per square metre of surface area
M&L for treating the soil along with external perimeter of building at the rate of 2.25 litre of emulsion per metre of the perimeter wall
S&F Anodised aluminium door shutters power coated ,as a fixed frame, sliding frame, any type aluminium section weighing 0.55kg/m including necessary joining cleats, glazing clips, rubber packing, anodised alumnium snap beading, screws etc. complete all as specified and directed by Engineer-in-Charge.
S&F Anodised aluminium window and ventilator shutters power coated, fixed type,sliding type or any type without sash bar, aluminium section weighing 0.55kg/m including necessary joining cleats, glazing clips, rubber packing, anodised alumnium snap beading, screws etc. complete all as specified and directed by Engineer-in-Charge.
S & F powder coated aluminium sections for doors, windows, ventilators, door partition including fabrication of frame shutters and fixing with necessary lugs, cleats, rollers, handles, locking arrangement etc. including all accessories such as glazings clips, and rubber beadings for fixing glass panes in frame complete all as specified and directed by Engineer-in-Charge. Note : (i) Glass panes will measured & paid separately . (ii)The quoted rate shall be inclusive of cost of rubber beading however it will be not be weighed and paid separately.
M&L for 5.5 mm thick antilo sheet glass, ordinary quality and glazing with aluminium beads and rubber gaskit in square exc 0.5 sqm in each pane frosted on one side complete all as specified and directed by Engineer-in-Charge.
Supply and fix 15 micron coloured aluminium anodised grill design No DG-117,10 mm thick including F Sections complete all as specified and directed by Engineer-in-Charge. Make :- M/s Deco grill / M/s Royal grill or Equivalent as approved by GE.
Mortice lock, vertical type, size 100 mm brass 4 lever
S&F aluminium (extruded section) body door closer hydraulically regulated designation No 3, universal type,suitable for door shutters of 851 to 1000mm in width and weight between 61 to 80 kg complete all as specified and directed by Engineer-in-Charge.
M&L for double action floor spring hydraulically regulated made up of minimum 1.25 mm thick aluminium alloy sheet foundation box, main body with stainless stell cover, governing pivot made of brass, other parts made of mild steel heavy duty and fixed
Supply & fix 100 mm size butt hinges, heavy weight, cold rolled mild steel complete all as specified and directed by Engineer-in-Charge.
Supply & fix 200 mm length aluminium anodised barrel tower bolt extruded section complete all as specified and directed by Engineer-in-Charge.
Material and labour in repair for floor door stopper of aluminium alloy body and tongue, anodised , with hard drawn steel spring overall length of cover plate 140 mm, complete all as specified and directed by Engineer-in-Charge.
S&F stainless steel wire cloth, 0.36 mm nominal dia of wire and average width of aperture 1.40 mm and fixed with stainless steel wire staples complete all as specified and directed by Engineer-in-Charge.
Supply & fix 300mm long aluminium alloy, anodised sliding door bolt with haps, staple(bolt type) and fixing clip of sheet, cast or extruded section and fixing bolts and sliding bolts of extruded section or cast aluminium alloy complete all as specified and directed by Engineer-in-Charge..
Supply & fixed mild steel curtain rod powder coated with fixing side brackets, end cups, rings @ 10 Nos per RM and fixed with PVC rawl plugs & steel screws complete all as specified and directed by Engineer-in-Charge.
M&L for PCC 1:3:6 type C2 40 mm graded aggregate150 mm thick as in flooring complete all as specified and directed by Engineer-in-Charge.
M&L 100 mm thick cement concrete type B-0 (using 20mm size graded stone aggregates) floor , finish the surfaces even and smooth using extra cement including necessary form work complete all as specified and directed by Engineer-in-Charge.
M & L Hardcore of broken bricks of gauge n. exc 63mm, deposited spread and leveled in layers n exc 15 cm thick watered and rammed to a true surface complete all as specified and directed by Engineer-in-Charge.
M&L for 25mm thick sand layer complete all as specified and directed by Engineer-in-Charge.
M&L Machine pressed precast concrete interlocking paver block,coloured rubber moulded any shape and size 60mm thickness, M-35 Grade with grey cement and pigment complete all as specified and directed by Engineer-in-Charge.
M&L 50 mm PCC 1:3:6 type C1 using 20 mm graded stone aggregate as in plinth protection finished even and smooth without using extra cement including necessary complete all as specified and directed by Engineer-in-Charge.
M&L 100 mm thick Plain cement concrete (1:2:4) typeB-1 using 40mm graded stone aggregate as in sub base of floors complete all as specified and directed by Engineer-in-Charge.
M&L Pre-cast cement concrete block masonry with solid bloacks, exc.10 cm in width and setting in mortar, complete all as specified and directed by Engineer-in-Charge.
S& F suspended false ceiling make Armstong ORCAL extra microperforation size of 600 x 600 x 15 mm Ceiling Tiles over suspension metal system (MICRO LOOK) designer grid (15 mm grid 8mm return) SILHOUETTE X L 15 MM (NOMINAL) of Armstorng make complete or equivalent brand of make including necessary hanging system arrangement complete which is required to be made from existing RCC roof / stone /slab/ acsheet roofand similar of building incl dismantling of existing ceiling complete all as specified and directed by Engineer-in-Charge.
M&L for ultra charged vitrified Ceramic tiles 10 mm thick (Square/rectangular) polished area of each tile not exceeding 0.36 sqm in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over 15 mm thick screed bed in CM 1:6 complete all as specified and directed by Engineer-in-Charge.
M&L glazed tiles digital coloured ceramic tiles 300x450x7mm thick in vertical surfaces such as skirting and dados set and jointed in neat cement slurry pointed in coloured cement to match including 15 mm thick plastering in CM 1:4 complete all as specified and directed.
M&L for point wiring with 1100 volts grade PVC insulated FRLS multistranded copper conductor cable 1.5 sqmm (Phase - Red, Neutral - Black) and earth continuity conductor 1.5 sqmm (Green) drawn into and including concealed rigid non metallic PVC conduit medium grade not less than 20 mm dia ISI marked ivory colour with all conduit fittings / fixing accessories and sunken modular GI metal boxes not less than 1.0 mm thick and white modular mounting cover plates with frame for mounting modular switches, sockets, fan regulators etc as required for One light point controlled by one switch.
All as per item No 66 above but one fan point controlled by one switch.
All as per item No 66 above but one socket outlet 6 amp controlled by one switch on the same board with other switches.
All as per item No 66 above but one socket outlet 6 amp controlled by one switch on indepdendent board.
M&L for point wiring with 1100 volts grade PVC insulated FRLS multistranded copper conductor cable 2.5 sqmm (Phase - Red, Neutral - Black) and earth continuity conductor 1.5 sqmm (Green) drawn into and including concealed rigid non metallic PVC conduit medium grade not less than 20 mm dia ISI marked ivory colour with all conduit fittings / fixing accessories and sunken modular GI metal boxes not less than 1.0 mm thick and white modular mounting plates with frame for mounting modular switches, sockets as required for 3 pin 16 amps socket outlet point controlled by one switch.
S&F modular switch one way 6 amp 1 module all as per Legrand Mylinc cat ref no. 675501 or equivalent as approved by GE.
S&F modular switch one way 16 amp 1 module all as per Legrand Mylinc cat ref no. 675511 or equivalent as approved by GE.
S&F modular socket 6/16 - 2/3 pin combined 2 module all as per Legrand Mylinc cat ref no. 675555 or equivalent as approved by GE.
S&F modular socket 6 amp 2/3 pin combined 2 module all as per Legrand Mylinc cat ref no. 675550 or equivalent as approved by GE.
S&F modular hum free electronic step fan regulator, 100 watt 2 module all as per Legrand cat ref no. 675530 or equivalent as approved by GE.
S&F ceiling rose 3 plates polycarbonate body complete.
S&F MCB distribution board, powder coated, CRCA steel sheet, degree of protection IP 43 - IK 09 with reversible double door, recess mounted, having insulated 100 amp tinned copper bus bar, neutral busbar, earth bar, din bar, detachable gland plate, interconnection, earthing connection, blanking plates in unused spaces as required SPN, 240 volts, 4 ways. Make - Legrand cat ref no 507610 or equivalent as approved by GE.
S&F MCBs of 'C' series having breaking capacity 10 KA, ISI marked including required wiring connections with copper lugs of suitable size provided in MCB DBs of Single pole 6 to 32 amp. Make - Legrand cat ref no 408587 to 408595 or equivalent as approved by GE.
(b) All as per item No 78 above but Double pole 10 to 32 amp. Make - Legrand cat ref no 408631 to 408636 or equivalent as approved by GE.
S&F energy efficient recessed mounted LED luminaire suitable for 2'x2' grid ceiling with flat diffuser and lumen output of 3300 lumens having constant current electronic driver duly connected with 0.5 sqmm white colour PVC insulated & sheathed three core flexible multi stranded copper conductor cable in renewal of any type luminaire as required. Make - Philips cat ref no. RC365B LED33- 6500 PSU OD WH or equivalent as approved by GE.
Supplying and fixing in repairs LED bulkhead fitting 9 watt IP 66 & IK 09 with polycarbonate body duly prewired connection with 0.75 sqmm PVC insulated & sheathed three core flexible multi stranded copper conductor cable all as per Philips cat ref no. WT202W LED6S CW PSU S2 PC or equivalent as approved by GE.
Supply and fixing ceiling fan 1200mm sweep 50 Hz AC 230 votls, 5 star rated in white colour with fan motor, blade set, 0.45 mtr down rod, canopy set, rubber reel including 0.5 Sqmm three core PVC insulated flexible copper conductor multistranded wire from fan motor to ceiling and provide suitable fan hook for hanging fan as required. Make : Havells Model No. ES-Plus 50 W or equivalent as approved by GE.
Supply and fix post top lantern light fitting weather proof indirect lighting solution having improved horizontal uniformity,with with reduced glare of 40 wat LED light Crompto Cat part No LPTC-40-CDL or equivalent as approved by GE.
Supply, laying and testing cable XLPE Insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 volts grade with stranded aluminium conductor of of 6 Sq mm 2 Core.
Supply, laying and testing cable XLPE Insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 volts grade with stranded aluminium conductor of size 16 sq mm 2 core.
Excavation in soft / loose soil in trenches not exceeding 1.5 m wide and not exceeding 1.5 m in depth and getting out complete all as specified and directed by Engineer-in-Charge.
Returning filling with earth obtained from excavation including spreading watering and consolidation in layers not exceeding 25 cms thick complete all as specified and directed by Engineer-in-Charge.
Removing surplus soil to a distance not exceeding 50 m and depositing at a level not exceeding 1.5 m above the starting point complete all as specified and directed by Engineer-in-Charge.
M&L for sand filling in trenches with clean dry fine river sand unwashed including gently punning around cables complete all as specified and directed by Engineer-in-Charge.
Supplying and laying old size bricks, common burnt clay building bricks sub class 'B' designation 75 laid in trenches over sand for cable protection complete all as specified and directed by Engineer-in-Charge.
M&L for pipe in pipe chemical earthing with GI pipe electrode 3.0 m long having outer pipe dia 50 mm & inner pipe dia 25 mm duly filled with highly conductive and anti corrosive compound tested from NABL certified Laboratory of required quantity in ground by digging a bore of 100 mm dia surrounded by soil friendly backfill compound including connection with galvanised earth wire 4 mm dia from earth electrode to the equipment to be earthed duly protected in 15 mm medium grade GI pipe upto 7.5 m, making PCC pit of size 0.3 m x 0.3 m x 0.3 m (inner size) in mix 1:3:6 type C1 with PCC 1:2:4 type B-1, 40 mm thick cover with lifting hook made out of 8 mm dia bar and testing on completion to achieve value not more than 2.0 ohm complete all as specified and directed by Engineer-in-Charge.
S&F Steel tubes ISI marked light grade galvanised with all fittings fixed to walls / poles / laid in road crossing etc as of 40 mm bore complete all as specified and directed by Engineer-in-Charge.
Schedule of Credit
NARAYAN SINGH NARENDRA SINGH AND COMPANY
VASU ENGINEERING SERVICES
M/S Mohan Lal Gupta
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .