Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹19.2 LAccepted-AOC RZ 50D GALI NO 13 VASHISHT PARK PANKHA ROAD NEW DELHI 110046 | NEW DELHI | DELHI | 110046 | L1 | Accepted-AOC Accepted | |
| 2 | L2₹22.8 L+₹1.8 L (8.49%)Rejected-Finance 205 PARSHAV VIHAR PLOT NO 50 IP EXTN PARPARGANJ DELHI 110092 | EAST | DELHI | 110092 | L2 | Rejected-Finance Other than lowest | |
| 3 | L3₹27.8 L+₹6.8 L (32.3%)Rejected-Finance | L3 | Rejected-Finance Other than lowest | |
| 4 | L4₹28.8 L+₹7.9 L (37.5%)Rejected-Finance HOUSE NO 95 STREET NO 08 JAWAHAR COLONY NEAR LAXMI DAIRY FARIDABAD SECTOR 22 HARYANA 121005 | FARIDABAD | HARYANA | 121005 | L4 | Rejected-Finance Other than lowest | |
| 5 | L5₹29.0 L+₹8.0 L (38.0%)Rejected-Finance HOUSE NO 251 E BLOCK ADARSH NAGAR BALLABHGARH FARIDABAD PIN 121004 HARYANA | FARIDABAD | FARIDABAD | HARYANA | 121004 | L5 | Rejected-Finance Other than lowest |
Tender Value
Refer Docs
EMD Value
₹89,800
Closing Date
3 Jan 2023, 6:00 pmClosed
GE (AF) Gurgaon No 1
GE (AF) Gurgaon No 1 Near Atul Kataria Chowk Gurgaon
CA NO. GE(P)AF/GUR-74/2022-23 REPAIR, MAINTENANCE , PERIODICAL SERVICES AND OVERHAULING OF UNSERVICEABLE ENGINE , ALTERNATOR, OVER HEAD ELECTRIC CRANE AND CONNECTED WORKS AT AF STATION GURGAON UNDER GE AF GURGAON NO 1
2022_MES_567366_1
GE (P) AF/Gur-74/2022-23
Open Tender
Miscellaneous Works
Item Rate
180 days
GE (AF) Gurgaon No 1
All as per NIT
10 documents required · 10 mandatory
₹500
GE (P) AF Gurgaon
₹89,800
Yes
3 Feb 2023
5 Dec 2022
5 Jan 2023
5 Dec 2022
3 Jan 2023
20 Dec 2022
Amount
M&L for Serviceing and periodical maintenance of DG sets of following capacity including cleaning internal parts thoroughly , replacement of oil filter, fuel filter, air cleaner, turbo charger etc and making smooth valve seats of inlet and exhaust valves including replacement of minor parts such as nut, bolts, washers, benjo nut, bolts, washers, locking nuts, circlips, `O’ Rings, Gasket, main cylinder head joint screws, stud small springs as deemed necessary or ordered complete and reassembling after replacement of unserviceable parts including painting with one coat of syntheteic enamemled paint of existing colour after removing dust, dirt and oil by castic soda etc, commissioning and testing on connected load complete all as specified and directed by Engineer-in-Charge of the following DG Sets:- (Note : The quoted rates of the contractor includes for fixing the serviceable parts in position and replacement of unserviceable parts with new parts. The new replaced spare parts which are catered in BOQ for supply only shall be measured and paid for separately . However essential minor parts/work which is required for sound engineering practice shall be deemed to include in the coated rate of this item):-
10/15/20 KVA DG Set.
25/30/40 KVA DG Set.
60/63/75 KVA DG Set.
100 KVA DG Set.
400 KVA DG Set.
500 KVA DG Set
Supply only of Lubricant oil filter element complete with plane washer, 'O' ring etc. complete all as specified and as directed by Engr-in-charge to incorporate in DG Sets repairs against items No 1 here-in-before for the following:- (Make-Mico/Flit Guard/ Donalson)
10/15/20 KVA DG Set.
25/30/40 KVA DG Set.
60/63/75 KVA DG Set.
100 KVA DG Set.
400 KVA DG Set.
500 KVA DG Set
Supply only of Fuel filter element complete with plane washer, 'O' ring etc. complete all as specified and as directed by Engr-in-charge to incorporate in DG Sets repairs against items No 1 here-in-before for the following:- (Make-Mico/Flit Guard/ Donalson)
10/15/20 KVA DG Set.
25/30/40 KVA DG Set.
60/63/75 KVA DG Set.
100 KVA DG Set.
400 KVA DG Set.
500 KVA DG Set
Supply only of Air filter element complete with plane washer, 'O' ring etc. complete all as specified and as directed by Engr-in-charge to incorporate in DG Sets repairs against items No 1 here-in-before for the following:- (Make-Mico/Flit Guard/ Donalson)
10/15/20 KVA DG Set.
25/30/40 KVA DG Set.
60/63/75 KVA DG Set.
100 KVA DG Set.
400 KVA DG Set.
500 KVA DG Set
Draining-out unsv lubrication oil from DG Sets of 10 to 400 KVA capacity of any make, cleaning thoroughly the same including supply and filling lubrication oil SAE-40 into the chamber/sump complete all as specified and directed Engineer-in-Charge. Make SERVO OF IOC/HINDUSTAN PETROLEUM/BPCL
Supply only flexible pipe, filter to lub oil cooler including banjo bolt washers, copper asbestos washer, spring washer nuts and bolts etc for following DG sets :-
10/15/20 KVA DG Set.
25/30/40 KVA DG Set.
60/63/75 KVA DG Set.
100 KVA DG Set.
Supply only V Belt to incorporate in DG Sets against item No 1 here-in-before complete all as specified and directed by Engineer-in-Charge for the following DG Sets :-
10/15/20 KVA DG Set.
25/30/40 KVA DG Set.
60/63/75 KVA DG Set.
100 KVA DG Set.
Draining out the diesel tank, cleaning / washing out the sedimentation using Kerosine and re-filling with diesel upto 100KVA DG sets (Note: Diesel will be provided by the department)
Same as per 8 but for above 100 to 500KVA DG Set
M&L for rewinding of alternator with approved copper wire all as per specified and directed by Engr-in-charge of the following DG Sets:-
10/15/20 KVA DG Set.
25/30/40 KVA DG Set.
60/63/75 KVA DG Set.
M&L for replacement of bearings and other parts of alternator complete all as specified and directed by Engr-in-charge of the following DG Sets:-
10/15/20 KVA DG Set.
25/30/40 KVA DG Set.
60/63/75 KVA DG Set.
Supply & fixing in replacement of Piston set upto 400KVA complete all as specified and directed by Engineer-in-Charge.
Supply and fixing in replacement of Piston Ring upto 400 KVA complete all as specified and directed by Engineer-in-Charge.
Supply and fixing in replacement of piston linear with linear ring complete of complete all as specified and directed by Engineer-in-Charge.
Supply and fixing in replacement of Cylinder Head Valve complete upto 100KVA DG set all as specified and directed by Engineer-in-Charge.
Supply and fixing in replacement of Cylinder Head Seal of complete upto 100KVA DG set all as specified and directed by Engineer-in-Charge.
Supply and fixing in replacement of Wall Seal of complete upto 100KVA DG set all as specified and directed by Engineer-in-Charge.
Supply and fixing in replacement of Push Guide Box of complete upto 100KVA DG set all as specified and directed by Engineer-in-Charge.
Supply and fixing in replacement of Front and Rear Oil Seal upto 100KVA DG set complete all as specified and directed by Engineer-in-Charge.
Supply and fixing in replacement of unserviceable Oil Pump with oil pump gear upto 100KVA DG set all as specified and directed by Engr-in-Charge. Make - Bosch
Supply and fixing in replacemet of Push Rod of upto 100KVA DG Set complete all as specified and directed by Engineer-in-Charge.
Supply and fixing in replacement of Fly Wheel Ring upto 100KVA DG set rating complete all as specified and directed by Engineer-in-Charge.
Supply and fix nozzle assembly (MICO NO 9430 0 ) complete with washer, banjo, bolt, copper washer etc suitable for 100 KVA DG set diesel engine set complete all as specified and directed by Engineer-in-Charge.
Supply and fix leak off pipe assembly for nozzle assembly complete all as specified and directed by Engineer-in-Charge.
M&L for disconnecting and taking down fuel filter assembly, cleaning thoroughly fuel filter housing complete and replacement of the fuel filters/fuel pipe etc complete all as specified and directed by Engineer-in-Charge. (Supply of item measured and paid seperately).
Supply only of Prefilter insert with sealing ring Make Mico Cat No 9451037404 complete all as specified and as directed by Engr-in-charge.
Supply only of Flexible fuel pipe cat No 34035030 complete all as specified and as directed by Engr-in-charge.
M&L for disconnecting and taking down old unserviceable self starter, 12/24Volt and dismantling complete for repair and replacement of the Following parts :- (a) Armature – 01 No (b) Solenoid switch – 01 No. (c) Field coil – 01 No. (d) Commutator – 01 Nos. (e) Carbon brush – 02 Nos. (f) Bendix drive – 01 Nos
S&F in replacement of water Temp sensor of upto 400KVA DG set complete all as specified and as directed by Engr-in-charge.
Disconnecting and taking down old unserviceable worn out 12/24 volts dynamo from the DG set, supply and fix, test new alternator A-115, 12/24 V with and incl. complete accessories such as connection , wiring, Nuts, Bolts Bracket for alteration, plain washer, spring washer, screws etc all as specified and directed. Make: LUCAS/Kirloskar/Cumins.
Supply and fix in replacement of complete radiator assembly suitable upto 40 KVA DG Set with all accessories such as Joints hoses, hose clip, nuts, bolts, washer, spring washers spacer, Fan guard, anti-vibration pad, screw sets etc complete all as specified and directed by Engineer-in-Charge.
Same as per item No 28 but for above 40 to 100KVA DG Set complete all as specified and directed by Engr-in-Charge
Supply only following spare parts for water pump assembly as repaired complete all as specified and directed by Engineer-in-Charge:-
Ball bearing –SKF-6203
Ball bearing –SKF-6303
Shaft for water pump
Bronze Impeller
Supply and fix battery leads, heavy duty copper stranded conductor with brass terminal and thimble 1.5 mtr long complete all as specified and directed by Engineer-in-Charge.
Supply and fix brass terminal for batteries including taking out and removing existing unserviceable terminals complete all as specified and directed by Engineer-in-Charge.
Dismantling the radiator of following DG sets, cleaning and de-scaling of chocked water tubes and jackets of radiator, cleaning the fins of radiator with acid and Jet spray including brazing of worn out copper tubes, body and for removing all chocked from the pipes by pressure washing and by using suitable solutions, checking for leakage, arresting leakage if any do welding / brazing, fusing, drying and refixing including replacement of the worn out minor spares such as Joint Hose Pipe, plain washers, spring washers, screws nuts, bolts, joints, rubber hoses with clip etc complete all as specified and directed of the following DG sets:-
10/15/20 KVA DG Set.
25/30/40 KVA DG Set.
60/63/75 KVA DG Set.
100 KVA DG Set.
400 KVA DG Set.
500 KVA DG Set
Supply and filling Coolant complete all as specified and directed by Engineer-in-Charge. Make : Castrol/HP/Power Oil
Supply and fix in replacement of unserviceable AVR for 15 to 40 KVA GEN SET, complete all as specified and directed by Engineer-in-Charge.
Supply and fix in replacement maintenece free battery (24 months replacement warranty) duly initial charged 12 volt 180 AH complete all as specified and directed by Engr -in-charge. Make: Exide/Amron/TATA Green.
Supply and fix in replacement maintenece free battery (24 months replacement warranty) duly initial charged 12 volt 90 AH complete all as specified and directed by Engr -in-charge. Make: Exide/Amron/TATA Green.
S&F in replacement Automatic transfer switch(ATS) Confirming to IEC: 60947-1 and IEC: 60947-6-1, four pole, AC-33A, 50 Hz 440 volt automatic/manual with in built time delay of capacity 200 Amps, complete all as specified and directed by Engineer-in-Charge.
S&F in replacement Voltage monitor relay (3 phase ) AC : 110/ 415Volt Setting 75 -100/300 - 400 V, complete all as specified and directed by Engineer-in-Charge. Make :- Teknika Type TE 211 flush or equivalent as specified in list of make.
Supply and fix in replacement Over current relay definite time Non directional ,definite time & current adjustable setting 0.5 -5A 1-10A /0.1-1A time 0-10 sec, complete all as specified and directed by Engineer-in-Charge. make :- Teknika Type TE 510 internal or equivalent as specified in list of make.
Supply and fix in replacement Battery Volt relay 12/24 volt DC, complete all as specified and directed by Engineer-in-Charge. Make :-Teknika or equivalent as specified in list of make.
Supply and fix in replacement Timer AC/DC on delay -sec, complete all as specified and directed by Engineer-in-Charge. Make :- Teknika TE 100 internal or equivalent as specified in list of make.
Supply and fix in replacement Battery charger 12 volt complete all as specified and directed by Engineer-in-Charge : make as per approved PS.
Supply only shut down coil suitable upto 400 KVA DG SET complete all as specified and directed by Engineer-in-Charge.
Taking out Unsv MCCB and supply and fix new Moulded Case Circuit Breaker (MCCB) AN frame of capacity 100 Amps, Four pole, 415 volts, 35 KA fixed thermal & fixed magnetic setting complete all as specified and directed by Engineer-in-Charge.
Taking out Unsv MCCB and supply and fix new Moulded Case Circuit Breaker (MCCB) AN frame of capacity 200 Amps, three pole, 415 volts, 25 KA fixed thermal & fixed magnetic setting complete all as specified and directed by Engineer-in-Charge.
Supply and fix in replacement Solenoid switch 12 volt, complete all as specified and directed by Engineer-in-Charge.
Supply and fix in replacement of HRC Fuse Link 125/100 A, 415 V AC, DIN Type, 100 KA. complete all as specified and directed by Engineer-in-Charge.
S&F in replacement Changeover switchs of capacity 200Amps ,4 pole ,offline manually operated 415V , 50 Hz conforming IS/IEC 60947-1 & 3 complete all as specified and directed by Engineer-in-Charge.
S&F in replacement Changeover switchs of capacity 160 Amps, 4 Pole offline manually operated 415V , 50 Hz conforming to IS/IEC 60947-1 & 3, complete all as specified and directed by Engineer-in-Charge.
S&F in replacment 3 Pole power contactor - Type MNX 110 of AC 1 current rating 160 Amp and AC3 rating 110 Amp with auxilary contact 2NO + 2 NC, complete all as specified and directed by Engineer-in-Charge. Cat Part No CS 94137 of make L&T or equivalent out of makes specified in list of makes.
S&F in replacment 3 Pole power contactor - Type MNX 95 of AC 1 current rating 160 Amp and AC3 rating 95 Amp with auxilary contact 2NO + 2 NC, complete all as specified and directed by Engineer-in-Charge. Cat Part No CS 94137 of make L&T or equivalent out of makes specified in list of makes.
S&F in replacment 3 Pole power contactor - Type MNX 150 of AC 1 current rating 160 Amp and AC3 rating 150 Amp with auxilary contact 2NO + 2 NC, complete all as specified and directed by Engineer-in-Charge. Cat Part No CS 94137 of make L&T or equivalent out of makes specified in list of makes.
M&L for painting of DG Sets (upto 400 KVA) with two coats of synthetic enamel paint of approved quality and shade over one coat of red oxide primer after preparing the surfaces (inner and outer) complete all as specified and directed by Engineer-in-Charge.
Supply and fix in replacement of Engine Safety Unit (ESU) of upto 40 KVA rating of DG Set in 54 ASP complete all as specified and directed by Engineer-in-Charge. . Make- Existing or as per approved PS.
Same as per item No 54 but for above 40KVA upto 100KVA rating of DG Set complete all as specified and directed by Engr-in-Charge
S&F 3 core, 2.5Sqmm FRLS flexible copper wire all as specified and directed by Engr-in-charge. Make : Finolex/Polycab/Havells
M&L for repair and testing of Control Panel/AMF Panel of any type upto 500 KVA rating of DG set capacity including programming , full copper wiring complete with washer, banjo, bolt, copper washer etc . (This includes the item involved in the repair and programming and S&F of other related items) complete all as specified and directed by Engineer-in-Charge.
Supply only Voltage Monitoring Relay 415 V, AC under Voltage complete all as specified and directed
Supply only Timer Switch 240V complete all as specified and directed
Supply and fix push button complete all as specified and directed
Supply only Voltage Amphere Frequency meter complete all as specified and directed
Supply only CT 900/5 complete all as specified and directed
Supply only Under Voltage Trip kit , 240V complete all as specified and directed
Supply only Control MCB SP 06-32 Amp, C Curve, 10KA complete all as specified and directed
Supply only Programmable Logical Array relay 24V DC including base plate complete all as specified and directed
Supply and fixing MXO contactor complete all as specified and directed
Supply only battery charger 24 V DC having the light for showing the supply , Battery full and charging complete all as specified and directed
Supply and fix in replacement of new Lock System set for multiple door DG Set complete of any KVA rating and any make complete all as specified and directed by Engineer-in-Charge.
Supply and fix in replacement of RPM Indicator complete all as specified and directed by Engineer-in-Charge. Make-Nippon or equivalent out of makes specified in list of makes.
Supply and fix in replacement of unserviceable AVR for 63 to 100 KVA GEN SET, complete all as specified and directed by Engineer-in-Charge.
S&F in replacement of unserviceable Feed Pump for any KVA DG set all as specified and directed by Engr-in-Charge. Make - Bosch
S&F in replacement of unserviceable Thermostat Valve for any KVA DG set all as specified and directed by Engr-in-Charge.
Supply only Distilled Water for Batteries all as specified and directed by Engr-in-Charge.
M&L for testing emission limit of DG sets upto 500KVA from a Govt authorized company. The testing includes Nox+HC, CO , PM & Smoke limit. After completion of testing the contractor also submit the report all as specified and directed by Engr-in-charge. Note: T&P and all other tech required items for the testing also included in the rate.
M&L in replacement of door hinges of upto 100KVA DG set complete all as specified and directed by Engr-in-Charge.
Supply, laying and testing in replacement of LT XLPE insulated screened PVC bedded galvanized steel strip or wire armoured electric power cable, heavy duty, 1100 Volts grade with stranded aluminium conductor of size 120 Sq mm, 3.5 core on pole, under floor, in pipe complete all as specified and directed by Engineer-in-Charge.
Supply, laying and testing in replacement of LT XLPE insulated screened PVC bedded galvanized steel strip or wire armoured electric power cable, heavy duty, 1100 Volts grade with stranded aluminium conductor of size 70 Sq mm, 3.5 core on pole, under floor, in pipe complete all as specified and directed by Engineer-in-Charge.
Supply, laying and testing in replacement of LT XLPE insulated screened PVC bedded galvanized steel strip or wire armoured electric power cable, heavy duty, 1100 Volts grade with stranded aluminium conductor of size 95 Sq mm, 3.5 core on pole, under floor, in pipe complete all as specified and directed by Engineer-in-Charge.
Supply, laying and testing in replacement of LT XLPE insulated screened PVC bedded galvanized steel strip or wire armoured electric power cable, heavy duty, 1100 Volts grade with stranded aluminium conductor of size 50 Sq mm, 3.5 core on pole, under floor, in pipe complete all as specified and directed by Engineer-in-Charge.
Supply, laying and testing in replacement of LT XLPE insulated screened PVC bedded galvanized steel strip or wire armoured electric power cable, heavy duty, 1100 Volts grade with stranded aluminium conductor of size 35 Sq mm, 3.5 core on pole, under floor, in pipe complete all as specified and directed by Engineer-in-Charge.
Supply, laying and testing in replacement of LT XLPE insulated screened PVC bedded galvanized steel strip or wire armoured electric power cable, heavy duty, 1100 Volts grade with stranded aluminium conductor of size 25 Sq mm, 3.5 core on pole, under floor, in pipe complete all as specified and directed by Engineer-in-Charge.
Excavation in trenches in soft/loose soil , not.exc 1.5 mtr wide and not.exc 1.5 mtr deep and getting out in soft/loose soil for laying of cable/foundation of pole and stay etc, complete all as specified and directed by Engineer-in-Charge.
Excavation in trenches in hard/dense soil , not.exc 1.5 mtr wide and not.exc 1.5 mtr deep and getting out in hard/dense soil for laying of cable/foundation of pole and stay etc, complete all as specified and directed by Engineer-in-Charge.
Removing excavated materials to a distance not exceeding 50 mtr and depositing where directed at a level not exceeding 1.5 mtr above ground level from starting point, complete all as specified and directed by Engineer-in-Charge.
Returning, filling in including spreading, levelling, watering and well ramming in layers n.exc 25 cm thick complete all as specified and directed by Engineer-in-Charge.
M&L for sand cushioning in trenches for protection of LT under ground cable including watering and consolidation ( to the thickness 18cm) complete all as specified and directed by Engineer-in-Charge.
Supply and laying well burnt sub class ‘B’ bricks, locally available in trenches for protection of underground cable complete all as specified and directed by Engineer-in-Charge.
Load Testing of all Gantry cranes as per IS code with no load and with 2 Ton load by an authorized company complete all as specified and directed by Engineer-in-Charge. Note: the rate for T&P required for shifting of load from one location to another is also included & test certificate will also be provided by the contractor after load testing.
M&L for Comprehensive Maintenance and repair of Electrical Overhead Gantry Cranes of Capacity 2 Tonne by Lubrication gears, Chain and Spockets arrangements in every quarter through out the year and repair / replacement all unserviceable parts, so that motion limiting devices are functioning properly, such as hoisting, limiting devices, cross-traverse and long travel limiting devices and pendent controllers with acceleration control with electrical protective devices complete all as specified and directed by the Engr-in-Charge. Note :- All New parts required for replacement are deemed to be included in the item rate except major parts which will be measured & paid seperately under relevant items here-in-after.
S&F in replacement thrust brake of EOT Crane all as specified and directed by Engr-in-charge
Supply only following Spare Parts of Gantry Cranes installed at different locations of Air Force Station Gurgaon, complete all as specified and directed by Engineer-in-Charge:-
Pendent Control Station Starter.
Contactor for Long Traverse Motor.
Contactor for Cross Traverse Motor.
Contactor for Hoisting(Lifting / Lowering) Motor.
Spocket Chain for Lifting and Lowering.
Spocket Main Gear drive by Chain as per Sample.
Bearing for E O T Crane of 2 Ton Capacity.
S&F in replacement of FLP-WP Enclosure with push button with isolator , Degree of protection as per IS:12063/1987 , IEC 60529/19891 , Temp Class -T6, CAT No : PBS/OA/174 complete change over box all as specified and directed by Engr-in-charge. Make: Sudhir switch gear pvt ltd/Shyam
M&L for locating the fault in EOT crane of 2 Ton capacity including rectification of minor defects such as tightening of nut and bolts, checking and rectifying loose connection of control panel, accessories and current collectors replacing of fuse wire etc to keep the crane functional and making the movement of entire unit as specified and directed by Engr-in-charge
S & F in replacement of FLP- WP Enclosure for Control station/MCB Dist Board IS: 13346/2004(IEC60079-0(2000)) & IP 66 Degree of Protection as per IS 12063/1987 flame proof pendant CAT part No - MCDB/186 complete all as specified and directed by Engr - In-Charge. Make : Sudhir switchgears Pvt LTd/Shyam
Labour and T&P for Shifting of DG Set by Crane and related required accessories within 54 ASP Domestic area, G Block and Technical area as specified and directed, complete all as specified and directed by Engineer-in-Charge.
M & L for complete servicing of spike barrier by taking out old oil and replacement with new HP oil and IS quality grease in barrier including welding work ,disposel of soil and junk acumulated arounds spikes complete all as specified and directed by Engineer-in-Charge.
M&L in replacement of rewinding of electric motor 3000 RPM, 80 watt S.N 1015083629, Single phase oil dip motor with super enameled copper winding wire including bearing and bushes and other accessories required to make motor functional and testing on load complete all as specified and directed by Engineer-in-Charge.
M&L in replacement of rack and pinion helical type complete unit assembly complete all as specified and directed by Engineer-in-Charge.
M&L in replacement of RF Security remote system of spike barrier complete all as specified and directed by Engineer-in-Charge. Make -Airtech
M&L for Rewinding of Hoisting Motor of 10 HP, AC Type, 3 phase by super enamelled Copper winding wire of same gauge as of existing one including heating, varnishing and testing after completion, complete all as specifed and directed by Engr-in-charge.
M&L for Rewinding of Hoisting Motor of 5 HP, AC type , 3phase by super enamelled Copper winding wire of same gauge as of existing one including heating, varnishing and testing after completion, complete all as specifed and directed by Engr-in-charge.
M&L in replacement of Supply, installing, testing and commissioning factory made and tested AMF Panel 30 KVA Outdoor type, platform mounted, suitable for 415 Volts 3 Phase and neutral, 4 wire, 50Hz AC supply system. The panel shall be dust and vermin proof, protection class (IP-54) and made of 2.00 mm ( 14SWG ) thick CRCA mild steel sheet and mild steel, Mounting Channel work made out of 75 mm ), front opening type with proper ferrule & cable gland, internal wiring with PVC insulated multistranded copper conductor FR cable of adequate size but not less than 1.5 sqmm complete. All steel metal works including frame shall be with anticorrosive coating with seven tank process and finally epoxy polyester powder coating of Siemens grey shade 7035. The scope of work also comprising of the following:- ( LOCATION :- ) Make of Panel: Adlec/ Schneider / Universal Switch Gear Control/ Advance/ Tricolite.
S&F FRLS copper cable 19core, 1.5 Sqmm complete all specified and directed by Engr-in-Charge Make:Havells/Polycab/Finolex
Supply and Fixing chain link fencing including line wires, any mesh, size and type to any type of standards, rails, straining bolts, etc. including provision of binding wire with necessary excavation for bars and also making of gate for same material for entry and exist of size 5'x7' all as specified and directed by Engr-in-charge.
Supply and fix in replacement of FRLS 10 Sqmm PVC insluated Single Core flexible copper wire all as specified and directed by Engr-in-charge`
Excavation over areas, n exc 1.5m deep & getting out in soft / loose soil complete all as specified and directed.
M&L for PCC in foundations, filling and mass-concrete 1:3:6 type-C2 using 40 mm graded stone aggregate complete all as specified and directed
M&L RCC 1:2:4 (Nominal mix) type B-1 using 20 mm graded crushed stone aggregate as in foundations for placing DG set and mass concrete complete all as specified and directed. Notes :- (i) Concrete block should be in one water level and spirit level to be used to check flatness of the block surface. (ii) Foundation should be design considering safe bearing capacity of soil and DG set static and dynamic load. Anti-Vibration Mounts (AVMs) are provided to reduced generator set and noice transmission to the surrounding structure as per OEM of DG set instructions.
M&L for formwork to sides of concrete foundations, footings, bases of columns, raft & raft beams, sides & soffits of foundation & plinth beams; and similar work; verticle or to batter fair finished surfaces of concrete flat complete all as specified and directed.
M&L for mild steel TMT bars 10mm dia & over,cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends & binding with & including mild steel wire (annealed) not less than 0.9mm dia or securing with clips quality complete all as specified and directed.
S&F in replacement NO, push type element all as specified and directed by Engr-in-Charge
S&F in replacement NC, push type element all as specified and directed by Engr-in-charge
M&L for Rewinding of main host motor of 3HP AC type, Induction type, 3HP by super enamelled Copper winding wire of same gauge as of existing one including heating, varnishing and testing after completion, complete all as specifed and directed by Engr-in-charge.
M&L for Rewinding of motor of 0.5 HP AC type , induction type, 3 phase by super enamelled Copper winding wire of same gauge as of existing one including heating, varnishing and testing after completion, complete all as specifed and directed by Engr-in-charge.
S & F Flood light 150Watt capacity complete all as specified and directed by Engr-in-Charge Make: Crompton/Havells/Bajaj or equivalent out of make specified in list of make.
S & F Flood light 70Watt capacity complete all as specified and directed by Engr-in-Charge Make: Crompton/Havells/Bajaj or equivalent out of make specified in list of make.
Supply only Gear oil EP 90 all as specified and directed by Engr-in-charge.
Notes:- (a) The amount of Rs 176290.00 against Schedule of Credit shall be deducted from the total amount quoted against Sch 'A' while deriving the Contract Sum for Acceptance. (b) The items supplied by contractor as supply only shall be taken on charge by deptt. (c) Any disturbed surface during execution of work shall be made good as existing. Nothing extra shall be paid in this respect. The quoted rate are deemed to be included the same cost.
Saini Enterprises
S.R. Constructions
RND ENGINEERS & CONTRACTORS
national engineering
shiv shanker enterprises
M/S Anand Enterprises
Surjit and Sons
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .