| Sl No | Description | Qty | Unit | sheetal engineering L1 | D P ENTERPRISES L2 | M/S LADPURIA ENTERPRISES L4 | M/S ADHIKARI CONSTRUCTION CO. L3 |
|---|---|---|---|---|---|---|---|
| 1.00 | M&L and T&P for attending complaints related to ceiling Fan, exhaust fan, wall fan, padestal fan etc any sweep, any type, any make fixed at different locations including taking down and refixing, cleaning all dirt, dust etc, replacement of connection lead/wire checking for loose connections in circuit, oiling and greasing split/window pins & other minor items,unserviceable screws assembly,bearing, re-fixing and testing to make it functional complete all as specified and as directed. Note :- 1. Cost of capacitor, connecting wire,regulator,ball bearing ,gun metal bush,ceiling rose etc shall be measured and paid under relevent item . 2.Cost of petty stores such as grease, lubricating oil ,lock nut , cross pin, check nuts,rubber seal etc are deemed to be included in quoted rate. | 500 | Each complaint | 30 ₹15,000 Lowest | 30 ₹15,000 Lowest | 50 ₹25,000 | 49 ₹24,500 |
| 2.00 | M&L and T&P for attending complaints related to Geyser any capcity Inspection and maintenance of water heater (Geyser) of capacity, 25 lt to 50 litres including performing the following task at different locations at AF Stn Rajokri.
(a) Removing Geyser & flow unit & heating element & cleaning the inner, tank with suitable acid/Replacement of defective connection lead .
(b) Checking and setting of thermostat between 50 to 55 degree Celsius
(c) Check working of NRV stop cock, pressure release valve and servicing carefully to make it functional
(d) Repairing of earthing connection, power switch, socket connection replacement of indicator lamp to make it functional
(e) Examine water leakage and rectifying as required and replacement of rubber washer gasket etc to make it functional
(f) Inspect over flow vent pipe, safety valve and remove blockage if required to make it functional.
(g) Any other item required for making Geyser serviceable will be measured & paid seperately under respective items. | 250 | Each complaint | 30 ₹7,500 Lowest | 50 ₹12,500 | 50 ₹12,500 | 49 ₹12,250 |
| 3.00Common Notes for Item No 1 & 2- (a) At least 01 electrician with 01 helper has to be deployed for day to day complaint rectification of Fan and Geyser at airforce station Rajokri (b) Contractor must insure sufficient store and T&P for geyser such as pipe wernch,screw driver etc and T&P for fan repair such as bearing puller, Plier,Tester screw driver etc for attending complaint and stationary such as complaint slips, Registers etc.(c) Obtain user signiture on complaint slip and register & submitting the records to the office of Engr-in-charge. | |||||||
| 4.00 | M&L for Taking out of burnt coils of ceiling fan in replacement of all coils of ceiling fan motor, AC, 230 volt of 1200/1400 mm with super enamel copper winding wire of proper gauge, weight etc (having same nos of turns), winding using insulating materials varnishing, heating, baking, replacement of bearing, bush, shaft etc, re-assembling the fan after making it functional and testing ,maintain the speed of fan complete all as specified and as directed | 30 | Each | 300 ₹9,000 | 400 ₹12,000 | 280 ₹8,400 Lowest | 299 ₹8,970 |
| 5.00 | All as per Serial Item No 4 here in above but exhaust fan upto 450mm size/sweep | 15 | Each | 300 ₹4,500 Lowest | 400 ₹6,000 | 500 ₹7,500 | 399 ₹5,985 |
| 6.00 | All as per Serial Item No 4 here-in-above but Wall Mounting fan upto 750mm size/sweep | 10 | Each | 300 ₹3,000 Lowest | 1,200 ₹12,000 | 1,000 ₹10,000 | 499 ₹4,990 |
| 7.00 | All as per Serial Item No 4 here-in-above but Pedestal fan of any sweep/size. | 10 | Each | 300 ₹3,000 Lowest | 400 ₹4,000 | 400 ₹4,000 | 499 ₹4,990 |
| 8.00 | All as per Serial Item No 4 here-in-above but cabin fan of any sweep/size. | 10 | Each | 300 ₹3,000 Lowest | 500 ₹5,000 | 300 ₹3,000 Lowest | 499 ₹4,990 |
| 9.00 | M&L for spray painting of ceiling fan ,exhaust fan wall mounted,Pedustal fan of any size any type with one coat of synthetic enamelled paint after cleaning and making good the old damaged paint all as directed by Engineer- in Charge. | 50 | Each | 50 ₹2,500 | 20 ₹1,000 Lowest | 70 ₹3,500 | 49 ₹2,450 |
| 10.00 | supply only Fan capacitor up to 1.5 MFD complete all as specified and as directed. Make- Tibcon/Bajaj/Havells | 10 | Each | 19 ₹190 Lowest | 20 ₹200 | 30 ₹300 | 49 ₹490 |
Tender Value
₹40 L
EMD Value
₹80,000
Closing Date
23 Jul 2025, 6:00 pmClosed
GE (AF) GURGAON
GE (AF) GURGAON
REPAIR/REPLACEMENT OF LT UG CABLE ELECTRICAL APPLIANCES LT PANELS EARTHING AND CONNECTED ITEMS AT AF STN RAJOKRI UNDER AGE E/M (AF) ARJANGARH OF GE(AF) GURGAON
2025_MES_713224_1
GE/GUR-/NIT-19/2025-26
Open Tender
Civil Works
Item Rate
270 days
GE (AF) GURGAON
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE (AF) GURGAON
₹80,000
12 Sept 2025
25 Jun 2025
25 Jul 2025
25 Jun 2025
23 Jul 2025
9 Jul 2025
Amount
M&L and T&P for attending complaints related to ceiling Fan, exhaust fan, wall fan, padestal fan etc any sweep, any type, any make fixed at different locations including taking down and refixing, cleaning all dirt, dust etc, replacement of connection lead/wire checking for loose connections in circuit, oiling and greasing split/window pins & other minor items,unserviceable screws assembly,bearing, re-fixing and testing to make it functional complete all as specified and as directed. Note :- 1. Cost of capacitor, connecting wire,regulator,ball bearing ,gun metal bush,ceiling rose etc shall be measured and paid under relevent item . 2.Cost of petty stores such as grease, lubricating oil ,lock nut , cross pin, check nuts,rubber seal etc are deemed to be included in quoted rate.
M&L and T&P for attending complaints related to Geyser any capcity Inspection and maintenance of water heater (Geyser) of capacity, 25 lt to 50 litres including performing the following task at different locations at AF Stn Rajokri. (a) Removing Geyser & flow unit & heating element & cleaning the inner, tank with suitable acid/Replacement of defective connection lead . (b) Checking and setting of thermostat between 50 to 55 degree Celsius (c) Check working of NRV stop cock, pressure release valve and servicing carefully to make it functional (d) Repairing of earthing connection, power switch, socket connection replacement of indicator lamp to make it functional (e) Examine water leakage and rectifying as required and replacement of rubber washer gasket etc to make it functional (f) Inspect over flow vent pipe, safety valve and remove blockage if required to make it functional. (g) Any other item required for making Geyser serviceable will be measured & paid seperately under respective items.
Common Notes for Item No 1 & 2- (a) At least 01 electrician with 01 helper has to be deployed for day to day complaint rectification of Fan and Geyser at airforce station Rajokri (b) Contractor must insure sufficient store and T&P for geyser such as pipe wernch,screw driver etc and T&P for fan repair such as bearing puller, Plier,Tester screw driver etc for attending complaint and stationary such as complaint slips, Registers etc.(c) Obtain user signiture on complaint slip and register & submitting the records to the office of Engr-in-charge.
M&L for Taking out of burnt coils of ceiling fan in replacement of all coils of ceiling fan motor, AC, 230 volt of 1200/1400 mm with super enamel copper winding wire of proper gauge, weight etc (having same nos of turns), winding using insulating materials varnishing, heating, baking, replacement of bearing, bush, shaft etc, re-assembling the fan after making it functional and testing ,maintain the speed of fan complete all as specified and as directed
All as per Serial Item No 4 here in above but exhaust fan upto 450mm size/sweep
All as per Serial Item No 4 here-in-above but Wall Mounting fan upto 750mm size/sweep
All as per Serial Item No 4 here-in-above but Pedestal fan of any sweep/size.
All as per Serial Item No 4 here-in-above but cabin fan of any sweep/size.
M&L for spray painting of ceiling fan ,exhaust fan wall mounted,Pedustal fan of any size any type with one coat of synthetic enamelled paint after cleaning and making good the old damaged paint all as directed by Engineer- in Charge.
supply only Fan capacitor up to 1.5 MFD complete all as specified and as directed. Make- Tibcon/Bajaj/Havells
supply only Fan capacitor 2.5 MFD complete all as specified and as directed. Make- Tibcon/Bajaj/Havells
supply only Fan capacitor 3.15 MFD complete all as specified and as directed. Make- Tibcon/Bajaj/Havells
supply only Fan capacitor 4 MFD complete all as specified and as directed. Make- Tibcon/Bajaj/Havells
supply only ball bearing/shaft suitable/as per existing sample for exhaust fan, ceiling fan and pedestal fan/wallmounted fan/cabin fan etc complete all as specified and as directed. MAKE : NBC, SKF
supply only Gun metal bush for ceiling fan/Exhaust fan of any size/make/sweep complete all as specified and as directed
Supply and fixing ‘U’ clamps for hanging ceiling fan with all nuts & bolts, washer, suitable size with rubber real complete all as specified and as directed
Supply and Fix in repairs ceiling fan canopy with nut and bolt of suitable size all as directed and specified.
Supply and fix in replacement of down rod for ceiling fan made out of 15 mm dia MS pipe complete with holes, slotted or threaded from 0.75 mtr to 1.5 mtr long all as specified and directed.
S & F nuts, bolts, washers, in any shape or size as directed including one coats of synthetic enamel paint over a coat of red oxide primer, complete all as directed .
S & F in replacemenmt of Fan blade for ceiling fan 1200/1400 mm sweep as per existing model complete all as specified and directed.
S & F replacement of Fan blade for Exhaust fan metal type any sweep as per as per existing model complete all as specified and directed.
S & F replacement of Fan blade for wall mounted fan any sweep as per as per existing model complete all as specified and directed.
S&F in replacement of metallic exhaust fan louvers of any shape (square or round as per site requirement ) upto 450 mm sweep complete all as specified and directed.
S&F ceiling fans complete with blades, down rods, electronic regulator and accessories, 230 V, 1200 mm sweep. Min air delivery 210 CFM with service value 6.00 BEE. Five star rated with brushless direct current motor (BLDC) with remote complete all as specified and as directed by Engr-in-Charge.
Supply and fix heavy duty copper wound exhaust fan, steel body AC single Phase. 230V of size 300 mm sweep 1400 RPM Double bearing with, 04 nos blades,frame,legs and louver complete with making arrangement for fixing of exhaust fan on steel/Aluminium frame window/ making opening in brick wall as per site requirement and also making good to disturbed surfaces as per matching to existing complete all as specified and as directed by Engr-in-Charge
Supply & fix wall mounting fans 230 volts single phase oscillating 400 mm sweep suitable for wall mounting complete all as specified and as directed by Engr-in-Charge.
S&F plastic body ventilation fan 250 mm 50 Hz , 240 volt 1250 RPM with copper wound motor including all fixing accessories complete all as specified and directed.
supply only Geyser flow unit / assembley made out of stainles steel as per matching shape/size or as per sample suitable for 25 to 50 litres capacity including safety valve as directed by Engr-in-charge.
supply only copper heating element of rating 1.5 KW to 2 KW to geyser 25 to 50 litres capacity, any type (normal and modular type), make / as per sample complete all as specified and as directed. Make - Theeta
supply only Thermostat as per sample suitable for 50 to 25 litres capacity of geyser complete all as specified and directed.
supply only Flexible SS braided connection havey duty stain steel 15 mm dia, length up to 750 mm long with union at both ends for 15 mm dia pipe complete all as specified and as directed
supply only Red and green indicator lamp as per existing size and shape complete all as specified and directed.
supply only Plug top, 3 pin, 15Amps all as specified and as directed. Make-Anchor/cona/havells
Supply and fixing modular type AC box 3 module operated with 20 Amp single pole MCB including 15 amp modular socket complete all as specified and directed by the Engr-in-charge.
supply only Anchor bolt type fastner brass size 10mm upto 150mm length complete all as specified and directed.
Dismentling the flow unit, inlet,outlet pipe of Geyser & taking out to repair the inner copper/steel tank of capacity 25/35/50 letres storage capacity by brazing at different spots after cleaning rusted leaking places and making tank leak proof including refixing, re-assembling & testing complete all as specified and as directed
Material and labour for painting of geyser 25 to 50 litres capacity with synthetic enamel spray paint with two coats of paint over one coat of red oxide primer including preparation of old surfaces complete all as specified and as directed
Supplying & Fixing of non return valve Brass metal vertical type size 15 mm complete all as specified and as directed
Supply & Fix for insulation of 25 to 50 Ltrs geyser as per existing insulating material in existing quantity for each geyser complete all as specified and as directed by Engineer-in charge.
S&F in replacement of Sheet metal enclosure factory made shutter type distribution board 2way (when MCBs are to be used) single pole and neutral, 240 Volts, with 200 Amp rated busbar, IP 43/IK09 (MCBs are to be measured & paid separately) complete all as specified and directed.
Supply & Fix in replacement of stainless steel water storage tank for upto 50 Ltrs capacity geyser as per existing gauge and shape complete all as specified and as directed by Engineer-in charge.
Supply & Fix in replacement of outer body 18 gauge complete with bottom and top cover as per matching to existing type and size for upto 50 Ltrs capacity geyser. Complete all as specifed & directed
Supply and fix electric water heater, storage type with SS tank and outer body made out of ABS & PP, heating element of 2 KW storage capacity 25 litre, BEE 5 Star rated complete with all accessories such as safety valve, thermostate, NRV, SS connection piece of suitable length etc complete all as specified and as directed by Engr-in-Charge. Make:-Racold /Havells/Crompton
S&F in replacement of metal clad plug top 240 volts 20 Amps with two phase and neutral pins and one earth pin complete all as specified and directed
S&F in replacement of metal clad socket 240 volts 20 Amps to fix two phase and neutral pins and one earth pin complete all as specified and directed
Supply and fixing 25 mtr long 2.5 cm wide and atleast .125 mm wall thickness self adhesive PVC insulated electrical tape roll of good quality complete all as specified and directed.
M&L for making arrangement for fixing of exhaust fan on steel/Aluminium frame window/ making opening in brick wall as per site requirement and also making good to disturbed surfaces as per matching to existing complete all as specified and directed.
Repair and Maintenance of split/Window type AC's of capacity 1.5/2 TR comprising of the following tasks installed at different locations including testing complete all as specified and directed by Engineer-in-Charge.(a) Inspecting and checking the Indoor/outdoor units for noise free operation (b) Checking the electrical connection for tightness (c) Cleaning the condenser with cleaning agent followed with pressurized water and cleaning the cooling coil with air blower.(d) Greasing/Oiling of condenser fan motor and blower motor. (e) Checking for any refrigerant leakage. (f) Checking for serviceability of remote control unit.
Supply and fixing in replacement of starting relay for split/window type AC units of capacity 2 TR as required at site complete all as specified and directed by Engineer-in-Charge.
Supply and fixing in replacement of starting relay for split/window type AC units of capacity 1.5TR as required at site complete all as specified and directed by Engineer-in-Charge. Make- (1) Hitech (2) Sriram
Supply and fixing in replacement of starting capacitor 80-100/100-120 mfd for split/window type A/C's of capacity 2 TR complete all as specified and directed by Engineer-in-Charge. Make- (1) Tibcon (2) Tesla (3) Epcos
S/F in replacement of running capacitor 30/36 mfd for split/window/window type AC unit as required at Site and as directed by Engineer-in-Charge. Make- (1) Tibcon (2) Tesla (3) Epcos
Taking out and refixing after rewinding including replacement of bush/ bearings of condenser fan motor of split/window type AC units of capacity 1.5/2 TR complete all as specified and directed engineer-in-Charge.Make- (1) Hitech (2) Sriram
Taking out and refixing after rewinding including replacement of bush/ bearings of blower motor of split/window type AC units of capacity 1.5/2 TR complete all as specified and directed engineer-in-Charge.
Disconnecting and taking down burnt compressor of capacity 2TR from split/window type AC unit and Supply and Fix new with charging of refrigerent after dehydration testing and vaccumming one as per existing model complete including testing all as specified and directed by Engr-in-Charge.
Disconnecting and taking down burnt compressor of capacity 2TR with CFC free Refrigerent (R410a,R32,R134a) from split/window type AC unit and Supply and Fix new with charging of refrigerent after dehydration testing and vaccumming one as per existing model complete including testing all as specified and directed by Engr-in-Charge.
Disconnecting and taking down burnt compressor of capacity 1.5 TR with CFC free Refrigerent (R410a,R32) from split/window type AC unit and Supply and Fix new with charging of refrigerent after dehydration testing and vaccumming one as per existing model complete including testing all as specified and directed by Engr-in-Charge.
Disconnecting and taking down burnt compressor of capacity 1.5 TR from split/window type AC unit and Supply and Fix new with charging of refrigerent after dehydration testing and vaccumming one as per existing model complete including testing all as specified and directed by Engr-in-Charge.
M&L for detecting the cause of leakage in any type/capacity of 1.5 tonne AC and ensuring the complete system leak proof and charging of refrigerant gas with appropriate quantity as directed including testing for smooth functioning complete all as specified and as directed. Notes :- (i) Dismantling of serviceable compressor , and re-installation of serviceable compressor after repairing are deeemed to be included in the quoted rates Gas and cost .
Supply & Fixing in replacement of new remote control unit (cordless) with PCB for 1.5/2 TR split/window type A/C unit complete all as specified & directed by engineer-in-charge.
Supply & Fixing in replacement new blower motor as per sample and existing model for split/window type A/C unit complete all as specified & directed by engineer-in-charge.
Supply & Fixing in replacement of air filter for split/window type A/C units of capacity 1.5/2 TR complete all as specified and directed by Engr-in-charge.
Material and Labour for providing sleeve type insulation 9mm thick for any dia copper tubing from Indoor to outdoor units complete all as specified and directed by Engr-in-charge.
Supply and charging CFC free Refrigerant (R410a,R32,R134a) to any type of AC complete all as specified and directed by Engr-in-Charge
Supply and charging R22 Refrigerant to any type of AC /AC plant complete all as specified and directed by Engr-in-Charge
S&F in replacement the new swing motor of existing model sample for split/window type AC 1.5/ 2TR unit complete all as specified and directed by Engr-in-Charge
M&L in replacement of copper tubing 10mm outer dia suitable for AC 2TR capacity complete all as specified and directed by Engr-in-Charge Make - (1) total line of carrier (2) met tube (3) diamond
All as per item No 67 but here in before but 15mm outer dia complete all as specified and directed by Engr-in-Charge Make - (1) totaline of carrier (2) met tube (3) diamond
Repair & maintenance of water coolers of any capacity comprising of the following tasks at different location complete all as specified and directed by Engineer-in-Charge. (a) Inspection, taking down, opening, dismantling, decaling, brushing cleaning of storage tanks (b) Examination water tightness, leak proof of storage tank after cleaning.(c) Carry out operation of all stop cock, push cock, float valve etc. (d) Inspect overflow and remove blockage if any. (e) Check and correct earth continuity of electric items (f) Check thermostat and test its functioning (g) Inspect drain pipe and remove blockage if any (h) Check and correct all electrical wiring & test its functioning (i) Testing of water cooler after repair
M&L for detection/rectification of leakage of gas in the system and gas charging in the system with appropriate quantity of gas including testing for smooth functioning of water cooler of any capacity complete all as specified and as directed at site by Engineer in charge. Note:- (i) Unserviceable condensing coil if required shall be measured and paid separately. (ii) The cost of dismantling of unserviceable compressor if required deemed to be included in unit rate. (iii) Compressor shall be measured and paid separately under respective items of Sch "A"
Supply & fixing in replacement of thermostat switch for existing model sample as required at site complete all as specified and directed by Engr-in-Charge. Make:- (1) Honeywell (2) Rapidcool (3) Daneoss
Supply and Fixing in replacement fan motor capacitor 2.5/3.15mfd. complete all as specified and directed by Engr-in-Charge.
Supply & fixing in replacement of overload protector for compressor of water cooler of any capacity as reqd at site complete all as specified and directed by Engr-in-Charge.
Supply & fixing in replacement of starting relay as required at site for water coolers of any capacity complete including connecting, testing complete all as specified and directed by Engr-in-Charge.
Disconnecting and rewinding of condenser motor single phase of 1/16 HP for water coolers & refixing the same with clamps bolts, nuts and rubber bushes including connecting, testing complete all as specified and directed by Engineer-in-Charge.
Supply and fixing in replacement of CP push cock ISI marked 15mm base complete all as specified and directed by Engr-in-Charge
Supply and fixing in replacement of starting capacitor 100/120 mfd for compressor complete all as specified and directed by Engineer-in-Charge
Supply and fixing in replacement of new condenser motor single phase of 1/16 HP as required at site for water cooler with clamps, bolts, nuts & rubber bushes complete including connecting testing complete all as specified and directed by Engr-in-Charge.
S&F in replacement of water cooler compressor reciprocating type (hermetically) sealed for any capacity as required at site water cooler complete all as specified and as directed.
Repair & maintenance of voltage stabilizer of capacity upto 5 KVA comprising of the following tasks at different location complete all as specified and directed by Engr-in-Charge. (a) Rewinding of Transformer copper coil with new copper wire as per existing gauge (b) Time delay relay-01 No. c) Cut out relay-01 No. (d) printed citcuit relay- 01 No.
S&F in repair/replacement of voltage stabilizer of 5 KVA capacity ISI marked with voltage range of 160 to 280 volts complete all as specified and directed by Engr-in-Charge. NOTE- Old stabilizer will be deposited to MES store.
Dismantling of split/window type AC 1.5/2.0 TR capacity from position after including disconnecting all connections between indoor and out door units,shifting,backup refrigerant for reuse and install at a place where directed carefully,including cutting on wall,making hole and make good disturbed surface properly matching surface,inspecting,servicing and refilling refrigerant and testing complete all as directed by Engr-In-Charge.
S&F in repair/replacement of indoor unit of 1.5/2 TR capacity split/window AC 230 Volts single phase all as specified and directed.
S&F in replacement of PCB card suitable for existing split/window type AC 1.5/2 Tonne AC of any make/model complete all as specified and as directed.
S&F in replacement of PCB suitable for 5 KVA voltage stabilizercomplete all as specified and as directed at site by Engineer in charge.
S&F in replacement of new transformer in replacement of burnt out transformer of 5 KVA voltage stabilizer complete all as specified and as directed at site by Engineer in charge.
Supply and fixing in replacement of Cable PVC insulated sheathed round shape three core 1100V FRLS grade stranded flexible copper conductor of size 2.5 sqmm complete all as specified and directed.
S&F in replacement of Cable PVC insulated unsheathed single core 1100V FRLS grade stranded flexible copper conductor of size 1.5 sqmm complete all as specified and directed.
Supply and fixing in replacement of Cable PVC insulated unsheathed single core 1100V FRLS grade stranded flexible copper conductor of size 2.5 sqmm complete all as specified and directed.
Supply and fixing in replacement of Cable PVC insulated unsheathed twin core of 23/0.0076 size flexible copper conductor complete all as specified and directed.
Supply and fixing in replacement of Cable PVC insulated unarmoured three core 1100V FRLS grade stranded flexible copper conductor of size 2.5 sqmm complete all as specified and directed.
S & F in replacement of sub main wiring with PVC insulated, FRLS unsheathed two single core cable 1100 volts grade with stranded copper conductor of size 4.0 sqmm (Nominal area) drawn in and including PVC conduit of suitable size as directed with and including one run of 4.0 sqmm multi stranded copper conductor single core PVC insulated, unsheathed cable of green colour as continuous earth wire including lugs etc connected and tested complete all as specified and as directed. Note: (i) Two runs of 4.0 sqmm cable and one run of 4.0 sqmm cable of earth continuity conductor and conduit shall be a unit length.
S&F in replacement switch piano type15 Amps one way ISI Marked complete all as specified and directed by Engineer-in-Charge.
S&F in replacement socket outlet 2-in-1, 6 pin 5 amp and 15 amps all as specified and directed.
S&F in replacement socket outlet 6A/16A-2/3 pin combined 2 module modular type complete all as specified and directed.
S&F in replacement switch 16 amps modular type one one way complete all as directed.
S&F in replacement of ceiling rose surface bakelite 63 x50mm three terminals complete all as specified and as directed.
S&F in replacement electronic fan regulator Step type complete all as specified and directed.
S & F in replacement of modular Fan Regulator fan step regulator,120W- single/double module ISI Marked complete all as specified as as directed.
S&F in replacement MCB SP 5 to 32 Amps, 240 volts curve 'B',breaking capacity 10KA, all as specified.
S&F in replacement of new outdoor unit of split AC of capacity 1.5/02 ton with suitable for existing indoor door unit from authorized dealers of company complete all as specified and as directed.
S&F in replacement of Evaporator coil for Window and split type AC 1/1.5/2 Ton capacity complete all as specified and as directed.
S&F in replacement of Suction/Discharge valve for Window and split type AC 1/1.5/2 Ton capacity complete all as specified and as directed.
Supply , laying & testing in repair for XLPE insulated, armoured, heavy duty electric cable with stranded aluminium conductor, 1100 volts grade, laid in trenches, sleeving through pipes or fixed on poles & walls or laid under floors including jointing with suitable size aluminium lugs complete of size 16 Sqmm nominal cross section x 2 core complete all as specified and directed
ditto but Size 25 Sqmm X 3.5 core
ditto but Size 35 Sqmm X 3.5 core
ditto but Size 50 Sqmm X 3.5 core
ditto but Size 95 Sqmm X 3.5 core
ditto but Size 400 Sqmm X 3.5 core
ditto butt Size 120 Sqmm X3.5 core
Supply and fixing of GI tubing, light grade, 40 mm bore with all fitting laid in trenches / pole / wall for protection of cables in repairs complete.
Supply and fixing of GI tubing, light grade, 80 mm bore with all fitting laid in trenches / pole / wall for protection of cables in repairs complete.
Supply and fix in repair cable jointing kit cold shrink type for 1.1 KV grade cable for straight through joint complete with Jointing material of tubular sleeve version and accessories suitable for 3½/ 4 core XLPE armoured Al conductor cable of size 25 to 50 sq mm complete
Supply and fix in repair cable jointing kit cold shrink type for 1.1 KV grade cable for straight through joint complete with Jointing material of tubular sleeve version and accessories suitable for 3½/ 4 core XLPE armoured Al conductor cable of size 70 to 150 sq mm complete .
Supply and fix in repair cable jointing kit cold shrink type for 1.1 KV grade cable for straight through joint complete with Jointing material of tubular sleeve version and accessories suitable for 3½/ 4 core XLPE armoured Al conductor cable of size 185 to 400 sq mm complete
Supply and fix ON load four pole changeover switch with front handle of 4 pole 415 volt 50 Hz 200 amps in SS Enclosure and Conforming to IS/IEC : 60947-1 & 3 fixed to existing panel wall by meand of angle iron of suitable size or by grouting with help of clamps etc complete all as directed .
Supply and fix ON load four pole changeover switch with front handle of 4 pole 415 volt 50 Hz 125 amps in SS Enclosure and Conforming to IS/IEC : 60947-1 & 3 fixed to existing panel wall by meand of angle iron of suitable size or by grouting with help of clamps etc complete all as directed
S&F in replacement of Danger notice plate of 1.6mm thick mild steel sheet vitreous enameled white with letter figures and conventional skull and bones in signal red colour and fix with MS clamp/Nut bolt for LT complete all as specified.
Supply only Aluminium lugs of any type complete all as per of sample of following sizes :-
(a) 16 Sqmm
(b) 25 Sqmm
(c) 50 Sqmm
(d) 70 Sqmm
(e) 95 Sqmm
(f) 120 Sqmm
(g) 150 Sqmm
(h) 240 Sqmm
Supply & Fixing in repair including making connection testing and commissioning of new MCCB 3 Pole, 415 V, fixed type, 25 to 100 Amps with breaking capacity 16 KA. Note: (a) make of MCCB shall be L &T , Havells, Strandard, crompton, C & S, Schneider or any other make as per the make in the existing pannel board or exactly suitable to the existing frame size. In case only one particular make is procuring by the bidder necceasry alteration required to fix the same at no extra cost shall be done by the bidder .(b) Type of MCCB weather with operating knob or handle type shall be procured as per site requirement.
Ditto, but MCCB TP 160 Amps, 36 KA with Adjustable thermal setting ( 80 to 100 %) complete.
Ditto, but MCCB TP 250 Amps, 36 KA with Adjustable thermal setting ( 80 to 100 %) complete.
Ditto, but MCCB TP 125 Amps, 36 KA with Adjustable thermal setting ( 80 to 100 %) complete.
Ditto, but 4 Pole, 415 V, Adjustable type, 160 Amps with breaking capacity 36 KA.
M&L for defect rectification in LT/HT cable laid in trenches up to 630 Sq mm 3/3.5 core cable with the help of electronic fault locating machine/FLC comprising of surge generator pulse/CFC /ECHO fault locator high pressure resistance and distance calculation for faults exposing the fault, removal of deteriorated portion and for cable joint complete all as specified and as directed.
M&L for disconnecting worn out cable of up to 630 Sqmm size from main control panel cutting worn-out portion and reconnecting with control panel with suitable size of thimbles by incl excavation of earth work for taking out cables from loop complete all as specified and directed.
M & L for Air termination of Lighting conductors, single pointed aluminium rod 12mm dia and 300mm long complete all as specified and directed .
M & L for Air termination, single pointed, copper rod 12mm dia and 300mm long complete all as specified and directed .
M&L for preparation of old steel painted surfaces of LT panels of any type and size by brushing/changing stain, greasy spots with thinner and apply two coats of spray painting with super enameled paint with colour of users choice approved by Dept. and writing the distribution area/location with white paint as directed to transformer indoor/outdoor installed at various different locations complete all as specified and directed at site.
M&L for carrying out horizontal boring below roads/PCC hard standing/Drains all as specified as directed for inserting GI pipe of the following size with a depth upto 1.5m & length of road upto 3 m of the suitable for 40 & 80 mm dia GI pipe as required complete all as specified and directed.
Supply and fix in repair ACB 4 pole 415 volts , 800 amps , AC 50 Hz with breaking capacity 50 KA conforming to IS/IEC-60947-2 with themal magnetic release and manual drawout type ( Thermally adjustable type ) inclding electrical connection as per site requirement complete all as specified and directed . Make - L&T / ABB / Siemence .
Excavation in trenches in soft/loose soil not exceeding 1.5 meter wide & not exc 1.5 mtr deep and getting out for taking out/laying cable, poles & stay etc complete all as specified and directed by engr-in-charge.
Returning, filling in including spreading levelling watering and well ramming in layers not exceeding 25cm thick after the cable have been laid and tested complete all as specified and directed by Engr-in-Charge..
Removal of excavated surplus soil to a distance not exceeding 50m and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified and directed by Engr-in-Charge.
M & L for dry sand cushioning to underground cables with 8cm thick before laying of cables and 15cm thick after laying ( total 23 cm ) and compaction till 18 cm thick for measurement purpose complete all as specified and directed .
Material labour for common burnt clay bricks, sub class 'B' grade laid in trenches for protection of UG cables perpendicular to the direction of the cables complete all as specified and as directed by Engr-in-Charge
Note for item no 145- (i) All MCCB shall be with adjustable Thermal magnetic setting (TMD).and shall be of same make of panel (ii) The board shall be epoxy polyster powder coated with structure siemens gray shade RAL-7035(iii) Sheet metal works shall be processed with nine tank process i.e. degreasing, water rinsing, activation, derusting, water rinsing, phosphating, water rinsing, passivation and water drying.(iv)Busbar shall be of electrolytic grade aluminium and shall be insulated with Red, Yellow, Blue and black colour heat shrinkable PVC sleeves.(v) Earth bus shall run throughout the length of the panel at the bottom of the panel.(vi) Each feeder shall be provided with individual inscription plate made out of black anodized Al/polycarbonate sheet with engraved/painted letters. (vii)Power switches/MCCB's will be provided with door operating mechanism, door interlock and padlocking feature.(viii ) Danger notice board with conventional skull & bone sign in postman red to be provided on front & rare side.(ix) All incoming & outgoing feeder shall be provided with cable glands at entry & exit of cable.(x) all MCCB's to be provided with rotary operating handle.
Maintenance / repairs to APFC panels, 3 phase AC 415 V, by skilled technician and replacement of unserviceable spares as specified below for capacities 60 to 100 KVAR including replacement of short circuited copper conductor cables with appropriate gauge PVC insulated stranded copper conductor cables and cleaning of all moving contacts of relay contactors, tightening of all terminals and testing afer repairs to ensure serviceability and corrected output at specified power factor all as specified and directed at site.
Supply and install in replacement of capacitor metalized poly propylene ultra heavy duty (LTXL) for 3 phase ,440 V, 50 Hz System for permissible non- linear load 15% complete all as specified.
(a)25 KVAr
(b)10 KVAr
(c) 5 KVAr
(d) 3.5 KVAr
(e)1.67 KVAr .Make : L & T , neptune ,Epcos & equivalent of other approved makes.
Material Labour And T&P for tree pruning near LT pole for clearing the conductor/light fitting by means of ladder/hydra as per directed location complete all as specified and directed.
M&L for attending complatints of street light, flood light,high mast light mounted at any height in pole/hanger in domestic and tech area of AFS Rajokri and connected road light by checking connection , serviceability of fittings, SMC boxes , MCB, thimbles or any other minor fault complete all as specified and directed. Note- (a) Arrangement of Ladder shall be done by contractor. (b) Arrangement of hydra as and when required or any other T&P, Grese for attending complaints of Hanger light/high mast light shall be done by contractor.(c) Complaints shall be rectified with in 24 Hours.if contractor fails to attend the complaints a recovery of Rs 500 per day shall be deducted from payment due to contractor(e) Weekly inspection of all security lights/street lights of area under AFS Rajokri shall be carried out and report shall be submitted to Engr-in-chage with out any delay.
Supply and fixing in rerplacement LED type street light 35 watt 230 watt volts AC outdoor type with IP 65 class protection with aluminium die cast housing glare free light distribution impact and corrosion resistant operating voltage range 140v to 270 V, total lumen efficiency =80 lm/watt , THD≤ 20 CRI>80 , colour temperature 6500 K, inbuilt surge protection = 5 Kv, 50000 Hrs burning hours complete all as specified and directed..
Supply and fixing in replacement LED type street light 60 watt 230 watt volts AC outdoor type with t IP 65 class protection with aluminium die cast housing glare free light distribution impact and corrosion resistant operating voltage range 140v to 270 V, total lumen efficiency =80 lm/watt , THD≤ 20 CRI>80 , colour temperature 6500 K, inbuilt surge protection = 5 Kv, 50000 Hrs burning hours complete all as specified and directed..
Supply and fixing in replacement LED type street light 90 watt 230 watt volts AC outdoor type with t IP 65 class protection with aluminium die cast housing glare free light distribution impact and corrosion resistant operating voltage range 140v to 270 V, total lumen efficiency =80 lm/watt , THD≤ 20 CRI>80 , colour temperature 6500 K, inbuilt surge protection = 5 Kv, 50000 Hrs burning hours complet all as specified and directed..
Supply and fixing in replacement LED type flood light 70 watt 230 watt volts AC outdoor type with t IP 65 class protection with aluminium die cast housing glare free light distribution impact and corrosion resistant operating voltage range 140v to 270 V, total lumen efficiency =80 lm/watt , THD≤ 20 CRI>80 , colour temperature 6500 K, inbuilt surge protection = 5 Kv, 50000 Hrs burning hours complet all as specified and directed..
Supply and fixing in replacement LED type flood light 100 watt 230 watt volts AC outdoor type with t IP 65 class protection with aluminium die cast housing glare free light distribution impact and corrosion resistant operating voltage range 140v to 270 V, total lumen efficiency =80 lm/watt , THD≤ 20 CRI>80 , colour temperature 6500 K, inbuilt surge protection = 5 Kv, 50000 Hrs burning hours complet all as specified and directed..
Supply and fixing in replacement LED type flood light 120 watt 230 watt volts AC outdoor type with IP 65 class protection with aluminium die cast housing glare free light distribution impact and corrosion resistant operating voltage range 140v to 270 V, total lumen efficiency =80 lm/watt , THD≤ 20 CRI>80 , colour temperature 6500 K, inbuilt surge protection = 5 Kv, 50000 Hrs burning hours complet all as specified and directed..
Supply and fixing in replacement LED type flood light 250 watt 230 watt volts AC outdoor type with t IP 65 class protection with aluminium die cast housing glare free light distribution impact and corrosion resistant operating voltage range 140v to 270 V, total lumen efficiency =80 lm/watt , THD≤ 20 CRI>80 , colour temperature 6500 K, inbuilt surge protection = 5 Kv, 50000 Hrs burning hours complet all as specified and directed..
Supply and fixing in replacement post top lantern LED type 40 watt 230 watt volts AC outdoor type with decorative post top for 360 degree indirect light IP 65 class protection with aluminium die cast housing cum heat sink circular canopy and clear acrylic cover for 360 degree indirect uniform glare free light distribution impact and corrosion resistant operating voltage range 140v to 270 V, total system lumen not less than 3200 lumens lumen efficiency =80 lm/watt , THD≤ 20 CRI>80 , colour temperature 6500 K, inbuilt surge protection = 5 Kv, 50000 Hrs burning hours including gountong of light grade pipe of suitable length on post complet all as specified and directed..
Supply and fixing in replacement LED Bollard 8 watt 230 watt volts AC outdoor type with decorative for 360 degree indirect light IP 65 class protection with aluminium die cast housing cum heat sink circular at the top and opaque acrylic cover for 360 degree indirect uniform glare free light distribution impact and corrosion resistant operating voltage range 140v to 270 V, total system lumen not less than 3200 lumens lumen efficiency =80 lm/watt , THD≤ 20 CRI>80 , colour temperature 6500 K/3500K/3000K as required at site, inbuilt surge protection = 5 Kv, 50000 Hrs burning hours complet all as specified and directed. Note- (1)Earth work and PCC shall be included in quoted rate.(2) Model and design shall be finalized by dept.
S&F in replacement of PVC SMC boxes with hinged door fixing of size 333mmx233mmx120 mm with MS clamp made to shape with necessery nut bolts and washers complete comprising of Aluminium busbar 63 Amps capacity of suitable size mounted over porcelain insulator withMS clamp nut bolts & washers incl MCB 6 Amps and making incoming and outgoing connections by taking out loops of cable of any size incl necessary excavations and other civil works all as specified and directed.
S&F in replacement LED rope light tri colour light saffron/white/green 8 watt per meter capacity capacity 120 no of LEDS with 15 RM legth with IP 65 Protection wrapped around poles of any length , height location and connection to electric cable/wire with the help of ladder/hydra as per site requirement complete all as specified and directed. Make- orient,havells,Bajaj
M&L for scrapping of surface of steel tubular poles of any size with emery paper and painting of poles with one coat of primer and two coats of aluminium paint of approved make incl writing pole nos on white backgrounds with black paint , complete all as specified and directed.
M&L for painting the surface of PCC poles of any size with one coat of primer and two coats of appex exterior paint of approved make incl writing pole nos on white backgrounds with black paint complete all as specified and directed.
S&F in replacement of existing unserviceable driver circuit with new one of any make or any model on existing LED street light luninatrie of wattage 45 to 120W complete all as specified..
S&F in replacement of existing unserviceable driver circuit with new one of any make or any model on existing LED Flood light luninatrie of wattage 60 to 200W complete all as specified..
S&F in replacement of existing unserviceable surge protector with new one of any make or any model on existing LED street/Flood light luninatrie of wattage 45 to 200W complete all as specified.
M&L street light bracket made out from GI Pipe 32 mm bore, light grade, 1.2 m long bent to shape including fixing 02 set of clamp made out from MS Flats of size 25x5 mm complete with nuts and bolts and washers of suitable size duly painted with two coats of aluminium paint over a coat of red oxide primer all as specified and directed .
S& Laying XLPE cable insulated screened PVC bedded galvanised steel strip or wire armoured electric power cables (heavy duty) 1100 V grade with standard aluminium conductor of size 16 Sqmm 4 core all as specified and directed.
S& Laying XLPE cable insulated screened PVC bedded galvanised steel strip or wire armoured electric power cables (heavy duty) 1100 V grade with standard aluminium conductor of size 10 Sqmm 4 core all as specified and directed.
S&F in replacement of timer switch for security light duly steel enclosed with locking arrangement fixed to wall/pole / existing panel by means of clamp.nut,bolt washers or by welding including following items-(a) MCCB 63 A 16 KA 4 Pole-01 Nos,(b) MCB SPN 16-40 Amp - 01 Nos, (c) Power Contactor ML3 40Amp , 3 Pole- 01 No, (d) Time switch analog dial type - 01 Nos, (e) Bypass arrangement for testing/repair of light.
Supply and fixing in replacement LED aviation light 10 watt duly enclosed in die cast aluminium casting with Red polycarbonate dome for better illumination, Integral driver , Supper flux 5mm 302nos LEDs incorporated with Ingress Protection : IP65, Protection against short-circuit, Protection against surge, Wide operating input voltage range 100 – 270VAC,burning hr 50,000Hrs.complete all as specified and directed.
M&L for testing the earth resistance value of any type of earthing such as chemical conventional in any location with the help of IS 9223 certified earth resistance meter by using three point/ fall of potential/star delta method as directed complete all as specified and directed by Engr-in-Charge. Note-(i) Earth test shall be carried out quaterly and report shall be submitted to Engr-in-Charge.(ii) Contractor has to provide caliberated Earth test meter.
M&L in replacement for Test point terminal block made of gun metal or phosphorus bronze size 75x75x25mm drilled and screwed including 3 nos. 8mm dia 25mm long hex. head screw complete all as specified and directed.
M&L in replacement Aluminium strip 25X3.15mm with saddles and fixing screws etc. for roof conductors and down conductors above ground complete with saddles and base insulators complete all as specified and as directed.
M&L in replacement GI strip 32X6 mm with saddles and fixing screws etc. for roof conductors and down conductors above ground complete with saddles and base insulators (porcelain /PVC/rubber) complete all as specified and as directed.
M& L in replacement for earth continuity conducted or main earthing lead fixed to wall/ceiling on batten or recess or chases or buried in ground or drawn in conduit/pipe or other directed situation for earthing etc as required 20x3 copper strip all as specified and directed.
S&F in replacement SMC/DMC insulator for seperation of earth strip from wall /ceiling including fixing aceessoriese such as nut bolt etc complete all as specified and directed.
M&L in repair/replacement for Earthing to machinary with galvanised steel earth plate electrode 600mm x 600mm x 6mm thick, buried directly in ground (earth pit not less than 2.25m below normal ground level) with top edge of earth plate not less than 1.5m below normal ground level connected to main earth strip of size 32x6mm galvanised iron strip by means of bolts, nut, check nuts and washers of galvanized iron or steel all as shown in electrical plate No.3 of MES Schedule pt-I 2009, GI earth lead shall be protected by GI pipe 40 mm dia medium grade and connected to machinary including excavation in any type of soil,returning filling, disposal of soil, providing charcoal dust and common salt upto top edge of earth plate, construction of PCC pit with RCC cover, funnel, watering pipe of 20mm dia GI light grade and provision of earth test point including testing on completion complete all as specified and as directed.
supply and replace of maintanance free unserviceable battery 12 V, 120 AH with initial charging and testing compleete all as specified and as directed. Make: Amaron/Exide/Microtek.
supply and replace of maintanance free unserviceable battery 12 V, 90 AH with initial charging and testing compleete all as specified and as directed. Make: Amaron/Exide/Microtek.
Supply and fillling pre mix coolent suitable for DG set complete all as specified and directed. Make-: Castrol / Kirloskar / HP
Maintenance / repairs to AMF panels, by skilled technician and replacement of unserviceable spares as specified below for capacities up to 250 KVA DG set including replacement of controle wiring with FRLS copper conductor cables with appropriate gauge and cleaning of all moving contacts of relay contactors, tightening of all terminals and testing afer repairs to ensure serviceability and corrected output at specified power factor all as specified and directed at site.
Supply in replacement only electronic timer any type for 0 to 10 Sec (on Delay)
Supply only in replacement electronic timer any type for 0 to 60 Sec (off Delay)
supply only in replacement Power contactor MNX 35
supply only in replacement Power contactor MNX 70
supply only in replacement Power contactor MNX 110
Supply only in replacement starting relay with sequence timer and master timer
Supply only in replacement Under voltage relay
Supply only in replacement over voltage relay
M&L for repaire/replacement of battery charger for AMF panel with existing Capacity complete all as specified and directed by Engr-In-Charge.
M & L for Cross arms, bracing, supports, clamps and back plate, fabricated from structural steel section including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as directed including two coats of synthetic enamel paint over a coat of red oxide primer, complete all as directed .Dismantling and taking out damage/rusted cross arms, bracings, supports, clamps and back plates from existing poles / dismantled poles / pole structures complete all as directed by EIC.
M & L for Cement concrete 1:4:8 type D-2 using 40mm graded stone aggregate as in foundation of pole or similar works complete all as specified and directed.
M & L for Cement concrete 1:3:6 type C-2 using 40mm graded stone aggregate in foundations, filling and mass concrete for fixing of pole complete all as specified and directed.
M & L for cement concrete 1:2:4 type B-1 using 20mm graded stone aggregate for copings of poles/stay/panels complete all as specified and directed.
Supply and erect true vertical steel tubular swaged pole confirming to IS-2713 part-II 410 SP-31 ,9.0 meter long complete with MS base plate of 6 mm thick of size 300x300 mm , finial taper plug, cap , bolt, nuts, eashers including painting externally with two coats of aluminium paint over a coat of red oxide primer for exposed portion and two coats of black bituminious paint for embeded portion in concrete as well as throughout internally including povision of white and blue colour strips with fluorescent paint upto 1.5 mtr height and numbering of pole complete all as specified and directes by engr-in-charge.
M&L for rewinding of motor of 5 hp capacity installed at High mast light complete all as specified and directed.
M&L for laying or grouting GI pipes 50 mm dia medium grade for cable protection in trenches / poles or mounting gate/garden light complete all as specified and as directed.
S& F in replacement of Solar Street Light fitting 20 watt all in one made with High Efficiency Mono Crystalline Solar PV Module, Lithium Ferro Phosphate battery with in-built BMS technology, High Efficacy LED, MPPT Solar Charge Controller and Aluminium Extruded body & is specially progrmmed to automatically control the dimming and brightness of light, which increases the backup time complete all as specified and directed.
S&F of LED spike light round shape with aluminium housing 12 watt with 390 lumen power factor more than 0.9 with IP 65 protection 220 to 240 volt AC with grouting in wall/floor with colour decided by dept complete all as specified and directed.
S& F mushroom shape gate light 14 watt with prismatic finish 200 mm dia 220 to 240 volt AC in unbreakable polycarbonate housing with IP 65 protection with B22d holder base including warm whie lamp of 14 watt duly mounting on 50 mm GI pipe complete all as specified and directed.
Supply and fixing pole 4 meters made out of cast iron with internal box post top light with matching tripple arm bracket stainless steel screws corrosion and UV resistant pu coating with warm white LED 40 watt including anchor bolts and plate / jig nuts and bolt of suitable size complete Note- Cost of earth work and PCC shall be included in quoted Rate. Make:- HI-Lite cat no - HL-7602 or equivalent from the make specified in list of makes.
M&L for taking down old unserviceable PCC pole including bracket wire fittings by complete exacavation from its base by means of hydra complete all as specified and directed
D P ENTERPRISES (BID ID -3360523)
M/S ADHIKARI CONSTRUCTION CO. (BID ID -3368505)
M/S LADPURIA ENTERPRISES (BID ID -3368844)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .