Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.2 CrAccepted-AOC MANSA | BATHINDA | PUNJAB | 151302 | L1 | Accepted-AOC Lowest Quoted Amount | |
| 2 | L2₹1.3 Cr+₹16.0 L (13.6%)Rejected-Finance | L2 | Rejected-Finance Higher Quoted Amount | |
| 3 | L3₹1.4 Cr+₹18.1 L (15.3%)Rejected-Finance | L3 | Rejected-Finance Higher Quoted Amount | |
| 4 | L4₹1.4 Cr+₹21.6 L (18.3%)Rejected-Finance | L4 | Rejected-Finance Higher Quoted Amount |
Tender Value
₹1.3 Cr
EMD Value
₹2.6 L
Closing Date
18 Aug 2026, 11:00 amClosed
DSCO Keshav Kumar
Opposite Aggarwal Hospital, Kishanpura Road, Sangrur
Supplying, Laying and Jointing of HDPE UGPL Works, Civil Works, Fixing of ARV, AAV, GV and all other allied works.
2026_DOA_172921_1
DSWC/SAN/2026-2027/15
Open Tender
Pipe Laying Works
Percentage
365 days
Sangrur
Please refer tender documents.
3 documents required · 3 mandatory
₹5,000
₹2.6 L
12 Oct 2026
3 Aug 2026
18 Aug 2026
3 Aug 2026
18 Aug 2026
3 Aug 2026
FINANCIAL BID NO.: DSWC/SAN/2026-27/15
Rates for Civil Works (Approved by CCS Punjab Chandigarh)
Name of the Firm/Bidder
Phone Number of Bidder Email id of Bidder
Total Estimated Amount of Work Rs.
Quoted by Contractor (As % less of Estimated Amount) Quote (+/-%)
Note: Please quote only figure (upto 2 decimal points) in above blue colour box in minus or plus. Do not put %age sign after this figure. Please check Quoted Rate in Next cell.
Name of Work :- Underground Pipeline Project for Utilization of Treated Water for Irrigation at STP Tapa, Distt. Barnala (5 MLD)
Sr. No. Items Description Amount (Rs.)
1 Laying of Pipeline and Allied Works
a Providing, Laying, Jointing and Excavation of Trenches with back filling of Pipeline system etc. complete (As Detailed in attached sheets)
b Civil Works for Sump Well for Irrigation with treated water (As Detailed in attached sheets)
c Civil Works for Pump Room for Irrigation with treated water (As Detailed in attached sheets)
d Providing and fixing of Motor Pumpset complete (As Detailed in attached sheets)
e Electrical Fittings for Pump House and Pumps (As Detailed in attached sheets)
2 Digital Electromagnetic Water Flow Meter (Lump sum) 100000
3 Auto Cut-off System and Sign Boards (Lump Sum) 50000
G. Total (1+2+3)
Department of Soil and Water Conservation, Punjab
Project : Underground Pipeline Project for Utilization of Treated Water for Irrigation at STP Tapa (Barnala) (5 MLD)
ABSTRACT SHEET OF MATERIAL FOR PIPELINE SYSTEM
S.No. Item Description CSR 2020/NS Item Qty Unit Rate Add GST on work cont. as per A & C Slip 5 Total Rate Amount (Rs.)
1 Excavation by mechanical means (JCB or Hydraulic excavator) in trenches for pipe lines with straight or open cutting in streets or open area including trimming and dressing sides levelling of beds of trenches to correct grade, cutting joint holes, refilling consolidation, watering, including the cost of dewatering of rain water, diversion for traffic, night signals. providing & fixing caution boards, crossing over trenches for access to the houses, watching, fencing, etc. and removal of surplus soil out side/inside the town involving lead upto 15 meter complete in all respect.
a Earth work upto 1.35 m. Depth for all classes of soil except rocky Deptt Rate 0.0 Cum 93.78 - 93.78
2 Providing, Laying using JCB/Crane, fixing & jointing of ISI Marked H.D.P.E. Pipes as per ISI - 4984- 1995 casting along the Trenches and laying the same in Trenches to correct alignment and gradients, cutting, jointing and testing complete as per specifications (Including Riser Pipe)
a H.D.P.E 250 mm o/d pipe of 4 kg./cm², PE-80 28.15 (F)(a) (A/C Slip-2) 2239 mtr 1738.24 0.0535
3 Supplying, fixing and jointing H.D.P.E pipe's specials complete as desired by Engineer-in-Charge.
a For pipe lines laid outside habitation & in the open area/ field (2% Extra will be taken for the respective i/d of pipe) 2% of 28.15 (E) (f) (250mm) 28.18 (b) 2200 mtr 34.76 0.0535
4 Supply & Installation of Alfa-Alfa valve (HDPE)
a 250 mm. Dia. (Rate approved by DSWC) NS 26 Each 1294 -
5 Providing & fixing Single air valve ISI Marked as per IS-14845 including jointing, cost of nut bolts and rubber insertion all carriages complete.
a C.I Single air valve screwed (Size 80mm) (For 250mm Dia HDPE Pipe) 28.29(e) 7 Each 4278.23 0.0535 4507.12
6 Providing and laying, jointing, fixing, testing ISI Marked G.I. Pipe (as per IS 1239) B Class, including cost of Specials such as tees, bends, sockets elbow etc., cutting, threading and testing in trenches in the ground complete.
a Supply & Jointing of 80 mm. Dia. G.I. Pipe (3 mtr for each ARV) 28.36 (h) (A/C Slip 4) mtr 1093.84 0.0535 1152.36
7 Providing & fixing C.I/D.I Flanged end, stem of SS (AIS 1410) and Bronze(gunmetal) working parts Sluice Valves ISI marked 14846-2000, including jointing , testing & cost of Nut ,Bolt & insertion sheet, all carriage complete (with the approval of Engineer in-charge) (Class PN-1 as per ISI)
a 250 mm i/d Sluice Valves flanged 28.27(A) (g) 3 Nos. 20973.48 0.0535
8 Providing, Stringing out, cutting, Jointing and testing of ISI Marked D.I. Double Flanged pipes with screwed flanged as per IS:8329- 2000, Class-K9 and laying the same in trenches to correct alignment and gradients,jointed with nut bolts and rubber insertion joints fitted complete including all cartage. (For Road crossing)
a 350mm i/d pipe lines laid complete 28.23 (i) 150 mtr 7846.88 0.0535
9 Providing & fixing ISI Marked Non-return valves flanged end class PN-1.0 as per IS:5312/2004 in pipe lines including jointing & cost of Nut Bolt , rubber insertion etc. complete. Note: If Non-return valves class PN-1.6 isused instead of class PN-1.0 , than 5% will be paid extra.
Class PN-1.0 as per ISI with gun metal flap
150mm i/d Non-return valve 28.31 (B) (h) 3 Each 8339.67 0.0535
10 Constructing brick masonry manhole in cement mortar 1:5 ( 1 cement : 5 coarse sand ) R.C.C. top slab 20cm thick using M-20 mix by using mixer and vibrator, TMT Fe500 @ 80.00 kg/per cum, foundation concrete 1:4:8mix (1 cement: 4 coarse sand : 8 graded stone aggregate 40mm nominal size) inside plastering 12mm thick with cement mortar 1:3 (1 cement: 3 coarse sand) finished with floating coat of neat cement and making 40mm thick benching in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) finished with a floating coat of neat cement, Orange coloured PVC steps including RCC cover with frame complete as per standard design complete in all respects.
Inside size 90x150 cm and 120 cm deep
For Chlorinated tank and Sump Well Water Control 29.55 b as per A&C slip 2 2 Each 22749 0.0535 23966.07
10.1 Extra payable for every 0.30 m additional depth of manhole chamber in item 29.55 upto 1.80 m increase in depth.
Department of Soil and Water Conservation, Punjab
Project : STP, Tapa, Barnala (5 MLD)
Sump well (9.6 lac litre)
Abstract of Cost
S. No. CSR 2020/NS Description Qty Unit Rate Add GST on work cont. as per A & C Slip 5 Total Rate Amount
1 6.19 Excavation in Soil (any type) using Hydraulic Excavator CK 90 with hydraulic excavator of 0.9 cum bucket capacity including cutting, trimming bottom and side slopes, in accordance with requirements of lines, grades and cross sections, including all lifts and combined lead upto 30m. 1402.89 Cum 34 0.0535
1.1 4.1 a Stone (building or pitching) Sand, Earth, Fly Ash, Bajri, Shingle, Spalls, Brick bats, Brick ballast and Stone metal. 2126.2 Cum 19.48 0.0535
1.2 29.7 B Extra for filling earth in 15 cm layers and compaction 149.47 Cum 52 0.0535
2 10.11 (b) ii Cement Concrete 1:4:8 with stone aggregate 40mm gauge mixing mechanical means using concrete mixer volumentric type 24.76 Cum 4362.96 0.0535
3 10.17 Reinforced cement concrete M-30 mechanically batch mixed using batch type concrete mixer as per IS:1791 and vibrated by needle vibrator but excluding steel reinforcement centring and shuttering in foundation and plinth. 68.25 Cum 6371.77 0.0535
4 10.22 Reinforced cement concrete M-30 mechanically batch mixed using batch type concrete mixer as per IS:1791 and vibrated by needle vibrator but excluding steel reinforcement centring and shuttering in superstructure 54.73 Cum 7122.77 0.0535
5 18.18 Cold twisted detormed (Ribbed/ Tor steel) Bars (Fe 500 grade as per IS 1786-2008) , for R.C.C works, where not including in the complete rate of RCC including bending and binding placing in position complete 133.74 Qtl 7919.61
6 9.1 Shuttering for faces of concrete foundations and foundation beam & plinth beam (vertical or battering) 12 Sqm 210 0.0535 221.24
7 9.3 Centering and shuttering for faces of walls, partitions,retaining walls and the like (vertical or battering) including attached pilasters, buttresses etc when curved. 255 Sqm 445 0.0535 468.81
8 13.92 Waterproofing of wet areas ( Concrete/ Masonary Surface ) and any water retaining structures such as swimming pools, water tanks, Bathrooms, toilets, balconies, planters etc with high performance polymer modified cementitionous coating ( DR. FIXIT FASTFLEX / Equivalent ) to provide tough film build-up and highly elastic film formation, which accommodates thermal movements so as to provide seamless coating without any joints to prevents water leakage. The scope of work also includes surface prepration and cleaning, washing and removing dust,dirt and loose particles from concrete / masonary surface complete in all respects. 415.11 Sqm 504.51 0.0535 531.5
9 18.4 Wrought iron & Mild steel ladders, framed grills, gratings etc. with ends of bars riveted or molded forged framed window guards, barred iron doors stair case iron railing etc. including cost of bolts and nuts, screws, welding rod complete fixing in position 19.5 Qtl 10296
10 16.2 Applying priming coat with metal primer on new steel or iron work including preparation of surface. 178.14 Sqm 24 0.0535 25.28
11 16.17 Painting two or more coats including priming coat with synthetic enamel paint in all shades on wood work, metallic or plastered, concrete surface to give an even shade Sqm 66 0.0535 69.53
Department of Soil and Water Conservation, Punjab
Project : UNDERGROUND PIPELINE PROJECT FOR UTILIZATION OF TREATED WATER FOR IRRIGATION AT S.T.P. Tapa, (Barnala) (5 MLD)
Construction of Pump House [5mx3.7m]
Sr No CSR 2020/NS Description of Items Qty Unit Rate (INR) Add GST on work cont. as per A & C Slip 5 Total Rate Amount (INR)
1 6.6 Earth work in excavation in foundations trenches etc. in all kinds of soil where Pick-Jumper work is not involved and not exceeding 2.0 metres depth including dressing of bottom and sides of trenches, stacking the excavated soil clear from the edge of excavation and subsequent filling around masonry in 15 cm, layers with compaction including disposal of all surplus soil as directed within lead of 30 metres. 13.93 Cum 182 0.0535 191.74
2 10.16 Reinforced cement concrete M-25 mechanically batch mixed using batch type concrete mixer as per IS:1791 and vibrated by needle vibrator but excluding steel reinforcement centring and shuttering in foundation and plinth 4.72 Cum 6081.77 0.0535
3 10.21 Reinforced cement concrete M-25 mechanically batch mixed using batch type concrete mixer as per IS:1791 and vibrated by needle vibrator but excluding steelreinforcement centring and shuttering in superstructure. 9.47 Cum 6831.77 0.0535
4 10.11 (b) ii Cement concrete 1:4:8 With stone aggregate 40mm gauge mixing by mechanical means using concrete mixer volumetric type 2.65 Cum 4362.36 0.0535
5 6.8 C (ii) Earth filling under floors with surplus soil containing more than 40% taking outside the premises in 15 cm layers including ramming watering and consolidated lead upto 1000 m 3.7 Cum 327 0.0535
5.1 10.26 Damp proof course 4cm thick of cement concrete 1:2:4 with 2 coats of bitumen 20/30 penetration at 1.65 Kg per sqm laid hot and sanded 3.11 Sqm 331 0.0535
6 18.18 Cold twisted detormed (Ribbed/ Tor steel) Bars (Fe 500 grade as per IS 1786-2008) , for R.C.C works, where not including in the complete rate of RCC including bending and binding placing in position complete 31.26 Qtl 7919.61
7 9.1 Shuttering for faces of concrete foundations and foundation beam & plinth beam (vertical or battering). 21.99 Sqm 210 0.0535
8 9.4 Centering and shuttering for columns (Square or rectangular or poly gonal in plain) 33.92 Sqm 477 0.0535
9 9.6 Centering and shuttering for sides and soffits of beam,beams, launching girders, bressumers, lintels. 25.68 Sqm 380 0.0535
10 9.8 Centering and shuttering for flat surfaces such as suspended floors, roofs, landings, chajjas, shelves etc. 22.94 Sqm 532 0.0535
11 11.6 (i) First class burnt brick work laid in cement sand mortar 1:5 in first storey upto 4 meter above plinth level 11.54 Cum 5817.26 0.0535
12 13.13 (i) Terracing consiting of tiles 22.86x11.43x3.83cm laid over 25 mm mud plaster 7.5 cm mud filling on another layer of 25mm mud plaster including two coats of bitumen laid hot at 1.65 Kg. /Sqm top of R.C.C. slab including grouting with cement sand mortar 1:4 and top surface to be left clean after wire brushing. 15.96 Sqm 755.87 0.0535
13 15.1 12.5 mm thick cement plaster 1:5 129.57 Sqm 189.23 0.0535
14 15.9 12.5 mm thick cement plaster 1:4 15.96 Sqm 197.23 0.0535
15 16.65 Preparation of plastered or concrete surface for painting (including sand papering the surface) using ready mixed cement based wall putty by applying two or more coats to get required finish 145.53 Sqm 80 0.0535
16 16.31 Applying priming coat with cement primer in all shade on newly plastered or concrete exterior surface Sqm 21 0.0535
17 16.59 (A&C Slip-1) Finishing walls with acrylic smooth exterior paint of required shade with two or more coats applied @ 1.67 litre/10Sqm over and including base coat of water proofing Cement Paint applied @ 2.20 Kg/10 Sqm Sqm 120 0.0535
18 14.10 (A&C Slip-1) Conglomerate floor 50mm thick cement concrete rete 1:2:4 on 100mm thick cement concrete 1:8:16 and 100mm sand filling using mechanical mixer for mixing of material 18.5 Sqm 749 0.0535
19 14.3 (A&C Slip-1) Base course of floor consisting of 100mm thick cement concrete 1:8:16 with stone aggregate 40mm and 100mm sand filling using mechanical mixer for mixing of material 8.5 Sqm 403 0.0535
20 14.4 Floating coat of 1:5mm thick neat cement laid in one operation to the topping 18.5 Sqm 29 0.0535
21 13.74 Providing and fixing 110 mm dia . U.P.V.C Rain water pipe of 4 kgf./sqm as per IS:4985 including jointing during masonary complete as per specifications and to the entire satisfaction of Engineer-in- charge. 8.3 Mtr 232 0.0535
22 13.75 Providing and fixing 110 mm dia. U.P.V.C bend for Rain water pipe as per IS:14735 including jointing complete as per specifications and to the entire satisfaction of Engineerin- charge No. 135 0.0535
23 13.45 Top Khurra 0.6mx0.6m for rain water pipe in 25mm thick cement concrete 1:2:4 over 50.00 thick cement concrete 1:8:16 2 Each 95 0.0535
24 13.46 Khurra on roof as per item No. 13.43 with C.I. Spouts 100 mm dia fixed in position. 2 Each 127 0.0535
25 14.137 (A&C Slip 2) Providing and laying 60 mm thick factory made cement concrete interlocking paver block of M-35 grade machine made rubber moulded smooth finish with strong vibratory process or with vibrohydraulic compaction machine and of approved size and design / shape laid in Ordinary Grey and pattern over and including 40 mm thick compacted bed of coarse sand, filling the joints with fine sand etc, all complete as per directions of Engineer-in-Charge IS code :15658 (2006) 8.5 Sqm 645 0.0535
26 18.29 (a) Providing and fixing M.S. angle iron 40x40x6mm chowkhat including iron hold fasts butt hinges fixed in position, finished with red lead non setting primer complete in all respect. (a)For single rebate. Kg 89 0.0535
27 18.1 Providing and fixing 14 gauge MS sheet garage doors with 40mmx40mmx6mm angle iron frame with diagonal braces 3.15mm gusset plates including locking arrangement with handles etc. complete in respects 5.04 Sqm 3900 0.0535
28 18.38 Providing & fixing of Box type steel windows, made of various ERW section outer 60mm x 25mm, central mullion 60mm x 25mm, for shutter 50mm x 20mm having thickness of 1.25mm (18 gauge), shash bar MS Tee 25mm x 3mm where required joints mitered and electrically flashwelded, with iron fittings including necessary iron handles, hinged cleat, tower bolts, iron hold fast and pintle hinges complete (excluding glazingand wire gauge) and finished with ready mixed paint red lead non setting primer complete as per specification, Drawings and to the entire satisfaction of engineer-in-charge. (Note:- Glazing, wire gauge and grill will be paid as per respective items) Kg 128 0.0535
29 18.25 (b) Supplying and fixing glass panes with glazing clips and special metal sash putty of approved make. (b) Glass panes 4mm or 10.75 kg / sqm exceeding 0.4 sqm of area Sqm 598 0.0535
30 18.27(A&C Slip 4) Wire gauge fixed in steel windows, of standard rolled steel section with 3mm thick flat iron cover moulding of 12.5 mm width, fixed with machine screws, complete in all respects. Sqm 906 0.0535
31 16.2 Applying priming coat with metal primer on new steel or iron work including preparation of surface. 5.04 Sqm 24 0.0535
32 16.17 Painting two or more coats excluding priming coat with synthetic enamel paint in all shades on wood work, metallic or plastered, concrete surface to give an even shade Sqm 66 0.0535
33 14.136 Providing and laying 60 mm thick factory made cement concrete interlocking paver block of M-30 grade machine made rubber moulded smooth finish with strong vibratory process or with vibrohydraulic compaction machine and of approved size and design / shape laid in ordinary grey and pattern over and including 40mm thick compacted bed of coarse sand, filling the joints with fine sand etc. all complete as per directions of Engineer-in-charge for Non traffic Areas and streets having width less than 3.05 mtrs. (Also not t used over footpaths) 18.29 Sqm 602 0.0535
(A) SubTotal Amount
Department of Soil and Water Conservation, Punjab
Project : STP Tapa (Barnala) (5 MLD)
Estimate for Cost of Pumping System Installation
Sr. No. CSR 2020/NS Description of items Unit Qty Rate (INR) Add GST on work cont. as per A & C Slip 5 Total Rate Amount (INR)
A Pumping set estimated cost:-
1 NS Providing, fitting & commesioning of Submersible pumpset with 35LPS flow and head 25mtr with Panel Board, Fuse Box, Cable for connection from Pump to Panel within the pump Room for 5 MLD discharge and 25 Meter Head (Non- Schduled Item, cost considered as per market rate) (excluding the cost of Panel Board, Fuse Box, Cable ) self propeller motor Set 3 486768.27 -
2 NS Single PVFD based Controller (18.5kW) IP54 Encloser for 3 pumps working, PLC Display (technical detail as mentioned below) with Single Phase prevention, overload, Dry-run Protection. Set 3 339290.97 -
2 NS Installation & Commissioning of one no. pump with one no. Control panel at site. Set 3 41772 0.18
3 28.21 (d) Providing, cutting, Jointing and testing of C.I. Double Flanged pipes with casted flanged as per IS:7181, class-B (ISI marked with the prior approval of Engineer-in-charge), including cost of nut bolts and rubber insertion complete including all cartage.150 mm i/d (Total 15 mts for each pumpset i.e. total of 150 mtrs for 3 pumpset) for suction pipe from sump to pumping units & for delivery pipe manifold connecting all pumping units to HDPE pipe main line mts 45 3131.5 0.0535 3299.04
4 28.8 (d) Extra for fixing of double flanged pipes in vertical position for over head reservoir & stand pipes, scaffolding, derricks, Jim poles, tools and plants, ropes, guys, etc. Complete as desired by Engineer-in-Charge.150mm i/d pipe lines laid complete (for suction pipes) mts 60 178.01 0.0535 187.53
5 28.24(a) Supplying and laying C.I. specials suction pipe from sump to pumping units as per IS:1538 complete as desired by Engineer-in-Charge conforming to ISI specifications.. C.I. specials upto 150mm i/d .
a Bend on suction and delivery pipes (150mm i/d weighing 45 kg each) Total weight for 3 pumpsets 45x6=270 kg kg 270 77.99 0.0535 82.16
b Flange (150mm i/d weighing 26 Kg each) Total weight for three pumpsets 26x10x3=780 Kg kg 780 77.99 0.0535 82.16
c Tee (150x150 mm weighing 47 kg each) Total weight for 3 tees= 47x3=141kg kg 141 77.99 0.0535 82.16
d One taper (150mmx200 mm weighing 51 kg each) 3x51=153 kg kg 153 77.99 0.0535 82.16
e Blank Flange (150mm i/d weighing 11kg each) Total weight for 3 Pumpsets 11*6=66Kg kg 66 77.99 0.0535 82.16
6 28.27 Providing & fixing C.I./D.I. Flanged end, stem of SS (AIS 1410) and Bronze (gunmetal) working parts Sluice Valves ISI marked 14846-2000, including jointing, testing & cost of Nut, Bolt & insertion sheet, all carriage complete (with the approval of Engineer incharge). (A) Class PN-1 as per ISI (C) 150mm i/d Sluice Valve flanged
Total for 3 Pumpsets 1x3=3 Nos. Each 3 20973.48 0.0535
7 28.29 (e) Providing & fixing Single air valve ISI Marked as per IS-14845 including jointing , cost of nut bolts & rubber insertion all carriages complete € C.I. Single air valve screwed (Size 80mm)
Total for 3 Pumpsets 1x3=3 Nos. Each 3 4278.23 0.0535
8 28.31 (B) (d) Proving & fixing ISI Marked Non-return valves flanged end class PN-1.0 as per IS:5312/2004 in pipe lines including jointing & cost of Nut Bolt , rubber insertion etc. complete. Note: If Non-return valves class PN-1.6 is used instead of class PN-1.0 , than 5% will be paid extra. (B) Class PN-1.0 as per ISI with gunmetal flap (d) 150mm i/d Non return Valve
Total for 3 Pumpsets 1x3=3 Nos. Each 3 8339.67 0.0535
9 28.96 (B) Jointing of C.I. Pipes as per IS:1536, Valves and specials with lead caulked joints ,including cost of lead , yarn and cost of labour fuel and tools etc with testing complete. For 150mm i/d pipe lines
Total for 3 Pumpset = 21 Nos. Each 21 1059.53 0.0535 1116.21
10 28.97 (C) Cutting of C.I. Pipes , specials and chipping or filing the surface to a uniform finish. © 150mm i/d pipelines
Total for 3 Pumpsets =21 Nos. Each 21 67.63 0.0535 71.25
11 28.12 Providing and fixing of Pressure switch of approved make in MS pipe line suitable for line presure up 15kg/cm2 & including connection with main panel etc. as required complete in all restect
Total for 3 Pumpsets 1x3=3 Nos. Each 3 3606.33 0.0535 3799.27
12 28.131 (e) Providing and fixing in position Cast Iron Foot valves flanged ends with rubber sheat as per IS 4038 including cost of Nut Bolt , rubber insertion complete in all respect 150mm i/d Cast Iron Foot valves Each 3 6198.88 0.0535 6530.52
13 28.121 (a) Providing and fixing S.S Pressure Gauge complete as required complete in all respect. ( a ) Dial diameter 150mm calibration 0-16 Kg Each 3 1027.61 0.0535 1082.59
14 28.128(c) Supplying, Laying, Testing and Commissioning of ISI marked BUTTERFLY VALVE PN 1.6, with Gun metal seal duly ISI marked complete with rubber insertion, nuts, bolts and washers, matching flanges of required thickness, etc. complete as per specifications. 150 mm i/d Each 3 5179.16 0.0535 5456.24
15 28.28 (a) Providing & fixing Fire Hydrants with jointing including all carriages complete (without Fire Hydrants surface box) Size 80mm complete in all respect. (a) C.I Fire Hydrants IS-908 Each 3 6770.93 0.0535 7133.17
16 18.7 Structural steel work in compound girders or Stanchions built up from two or more R.S. joists or channel section or plates & angles etc. including cutting and fixing all lattice bars, stiffeners, gusset plates, bolts, nuts, rivets, welding rod, etc. complete with flange plates, heads, sole plates, angle connections, etc. with hoisting and erecting in position
For suction pipe installing and dismantling 3 pumps Qtl 1.223 9394.28
Department of Soil and Water Conservation, Punjab
Project Name: Undergorund Pipeline Project for Utilization of Treated Water for Irrigation at STP, Tapa (5 MLD)
Elecrtical Estimate for Pump Room
Sr. No. CSR 2020/NS Description of items Unit Qty Rate (INR) Add Premium as per A & C Slip 3 Total Rate Add GST on work cont. as per A & C Slip 5 Total Rate Amount (INR)
1 34.02 RECESSED PVC CONDUIT PIPE WIRING SYSTEM WITH MODULAR SWITCHES: Wiring in PVC insulated copper conductor single core FR cable (ISI marked) overall 1.5sq. mm, 1100volts grade to be laid in heavy gauge PVC conduit pipe 20mm/ 25mm dia. (ISI Marked) recessed in wall etc., complete with powder coated/anodized concealed metal boxes (1.6mm thick with Brass lugs) required for suitable number of modules (Modular accessories) for having Step type electronic fan regulators (two module) 100watts, bell push, 6Amp. 2/3 universal socket (shuttered), 16/20Amp. combined/ universal Socket (shuttered), 6/10Amp. Switches, 16/20Amp. switches with indicator etc. and covered with Frame Plate etc., PVC connector (For Fan Box and Call Bell), Steel Hooks, Sheet metal fan box (1.6mm thick shape hexagonal), Circular junction Boxes (Four way PVC 1½" deep for walls and CI 3" deep for ceiling), bonding to earth with PVC insulated copper conductor single core FR cable (ISI marked) 1sq. mm, 1100volts grade (For 6Amp. wall socket & plug control point) and other petty material etc., including the cost of above material, cutting and filling up of chases (with finishing the surface):-
I (a) Wiring fan point (Without fan box) Each 2 829 0.25 0.0535 1091.69
I (b) Wiring fan point (With fan box) Each 2 919 0.25 0.0535 1210.21
ii Wiring light point Each 10 579 0.25 0.0535 762.47
v Wiring 6Amp. Wall socket point Each 2 470 0.25 0.0535 618.93
vi Wiring 16/20 Amp. Power plug control point Each 1 363 0.25 0.0535 478.03
2 34.09 PVC INSULATED FR COPPER CONDUCTOR CABLES: Supply and erection of PVC insulated FR single core Unsheathed copper conductor cable (ISI marked) suitable upto 1100 volts grade confirm to IS:694/1990 left bare in pipe or casing of suitable size complete in all respect as desired by the Engineer-in-charge:-
iii Overall size 2.5 sq. mm (Un-sheathed) Meter 100 27 0.6 0.0535 45.51
iv Overall size 4.0 sq. mm (Un-sheathed) Meter 100 39 0.6 0.0535 65.73
3 34.12 PVC, HDPE PIPES & PVC FLEXIBLE PIPES: Supply & erection of PVC Conduit Pipes (ISI marked) as per IS9537:Part-III & HDPE pipes (ISI marked) as per IS:4984:1995 for wiring urposes including bends, junction boxes, Steel hooks, M.S. saddle clamps and other petty materials etc., as per PWD General Specifications:-
(x) Heavy Gauge PVC Conduit Pipe 25mm dia (Flushed) Meter 50 48 0.4 0.0535 70.8
4 34.13 (xiii) G.I.Earthing: Earthing with G.I. wire/ rope in G.I. pipe partly recessed and partly on surface complete with 150cm long 50mm dia. G.I. earth pipe (Cutting threads and 36 Nos. holes, 1cm dia. to make a mesh around the GI Pipe) with G.I. reducing socket including erection of the same, 4.50 metre (14.76 feet) below ground level with 20Kg. charcoal & salt mixture etc., up to 8 metre in length (including boring & refilling).
(a) Earthing with 8 S.W.G. (4mm dia.) G.I. wire in 15mm dia G.I. pipe with G.I. reducing socket 50mm x 15mm (upto 8Metre in length) Each 3 2518 0.25 0.0535 3315.89
5 34.10 (B) XLPE INSULATED ARMOURED CABLES (LOOSE):- Supply, laying and erection of aluminium conductor XLPE insulated PVC sheathed armoured and served cable 1100 volts grade as per IS 7098 (Part- 1)1988 to be laid loose in the existing trench or pipe as per PWD General Specifications:-
xiii Overall size 95 sq mm (4 core) Armoured (Loose) Meter 200 409 0.95 797.55 0.0535
xxxvii Overall size 16 sq mm (4 core) Armoured (Loose) Meter 50 123 0.9 233.7 0.0535
6 34.16 (A) MINIATURE CIRCUIT BREAKERS: Supply and erection of Miniature Circuit Breaker MCB's for circuit protection against overload and short circuit current fault suitable for 240/ 415 volts 50cycles AC supply with breaking capacity of 10kA, Curve-C and low watt losses as per IS/IEC 60898-1, energy limitation class-3, true contact indication, label holder facility in the existing MCB distribution board as per PWD General Specifications including connections with suitable size of thimbles/lugs:-
ii MCB Single Pole 6-32 amp. (10kA, Curve-C) Each 6 134 0.5 201 0.0535
iii MCB Single Pole 40 amp. (10kA, Curve-C) Each 1 278 0.5 417 0.0535
7 34.16 C RCCB's: Supply and erection of RCCB (Residual Current Circuit Breaker) for Earth leakage protection suitable for 240/415 volts 50 cycles AC supply with breaking capacity of 10kA as per IEC 61008-1 in the existing MCB distribution board as per PWD General Specifications including connections with suitable size of thimbles/lugs
i RCCB Double Pole 16/25 amp. Sensitivity 30mA Each 1 1608 0.15 0.0535 1948.13
8 34.17 SHEET METAL DOUBLE DOOR DISTRIBUTION BOARD FOR MCB's/ RCBO's/ RCCB's: Supply and erection of sheet metal Double Door Distribution Boards IP 43- IK09 metal door (dust protected) as per IS 8623-1&3, IEC 61439-1&3 suitable for flush mounting with fully insulated copper busbars, shrouded neutral bars, earth bars, cement spill protector, colorcoded interconnecting wire set, cable ties, blanking plates and circuit identifications label and of required no. of ways for mounting miniature circuit breakers/ RCBO's/ RCCB's in the distribution board (For SP&N distribution board with provision DP MCB's/ RCCB's/ RCBO's as incomer and SP MCB's as outgoings and for TP&N horizontal distribution board with provision TPN/ FP MCB's/ RCCB's/ RCBO's as incomer and SP MCB's as outgoings) as per PWD General specifications including connections with suitable size of thimbles and bonding to existing earth etc:-
ii SP&N Double Door Distribution Board 8 way each Each 1 1169 0.15 0.0535 1416.27
9 34.25 CABLE TRAY: Supply and erection of MS perforated cable tray (MS Sheet thickness 2mm) with DA gray paint on the existing surface with the help of MS angle iron support (to be painted with approved paint) of size 50mm x 50mm x 6mm thick to be fixed with fastners/ nut & bolts etc., complete in all respect as desired by the Engineer-in-charge and as per PWD General Specifications:-
i Cable Tray Size 150mm X 50 mm X 50 mm (2mm thick) Meter 50 723 0.4 0.0535 1066.35
10 34.37 A (iv) Supply and erection of Double Walled Corrugated (DWC) HDPE pipe to be laid 1/2mtr. below ground level including excavation placing the pipe in position and back filling ith excavated soil etc. of the required size:- Double Walled Corrugated HDPE Pipe 120/103.5mm (Outer/ Inner dia.) Meter 200 276 0 276 0.0535 290.77
11 NS 2 Supply and installation of Heavy Duty Exhaust fan 450mm with 1400rpm. Approved Make Crompton, Havells, Bajaj or equivalent Each 2 4855 0 4855
12 NS 3 Supply and installation of Led Tube light 20-22 watt with make of Phillips, Bajaj and Wipro. Item to include all amterial and lobour complete as per Specification and entire satisfaction of Engineer In Charge. Each 5 450 0
13 NS 4 Supply and installation of Ceiling Fan 1200mm with Double ball bearing. Approved Make Crompton, Havelles, Bajaj or equivalent Each 2 2674 0
Total Electrical Estimated Amount
stage.html
html • 0.05 MB
tech_eval.pdf
fin_bid_open.pdf
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.54 MB
NITHDPE262715.pdf
Tender Documents • 0.52 MB
DNITHDPE262715.pdf
Tender Documents • 1.13 MB
FBHDPE262715.xls
Additional Documents • 0.22 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .