| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹18.9 LAccepted-AOC A 153 HQ CE EC KOLKATA LEKHAPANI POST TINSUKIA DIST ASSAM STATE | L1 | Accepted-AOC BEING LOWEST AND REASONABLE | |
| 2 | L2₹19.7 L+₹79,700 (4.22%)Rejected-AOC | L2 | Rejected-AOC NOT BEING L1 | |
| 3 | L3₹22.6 L+₹3.8 L (19.9%)Rejected-AOC 1 204 LOWER GROUND FLOOR SADAR BAZAR DELHI CANTT 110010 | NEW DELHI | DELHI | 110010 | L3 | Rejected-AOC NOT BEING L1 | |
| 4 | L4₹22.8 L+₹4.0 L (20.9%)Rejected-AOC C 9 53 IIND FLOOR SECTOR 08 ROHINI DELHI 110085 | DELHI | NORTH WEST DELHI | DELHI | 110085 | L4 | Rejected-AOC NOT BEING L1 | |
| 5 | L5₹23.6 L+₹4.7 L (24.8%)Rejected-AOC | L5 | Rejected-AOC NOT BEING L1 |
Tender Value
₹21.3 L
EMD Value
₹42,500
Closing Date
5 Jul 2021, 6:00 pmClosed
LT COL AYAN BISWAS
GE E/M RR HOSPITAL DELHI CANTT-10
CA NO GE/H-04/2021-22 NAME OF WORK PREVENTIVE MAINT/REPAIR OF UPS AT AH RR HOSPITAL UNDER GE E/M RR HOSPITAL DELHI CANTT-10
2021_MES_447500_2
GE/H-04/2021-2022
Open Tender
Electrical and Maintenance Works
Item Rate
330 days
GE E/M RR HOSPITAL DELHI CANTT
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE E/M RR HOSPITAL DELHI CANTT
₹42,500
Yes
21 Sept 2021
22 Jun 2021
7 Jul 2021
22 Jun 2021
5 Jul 2021
28 Jun 2021
Amount
Material and labour for comprehensive maintenance of following UPS system alongwith regular preventive maintenance service of UPS system and checking serviceability of on line UPS of any capacity make & type for following capacity installed in various Deptt/Wards /OT/ICU at AHRR complex ( P-100) in and including replacement of its faulty/worn out parts/components/accessorie and removal of any functional discorder of UPS system and to make UPS system serviceable complete round the clock to provide un-intrruped power supply to Hospital servic complete all as specified power supply to Hospital services complete all as specified and directed by Engr-in-Charge:- (a) 3/3.5 KVA capacity UPS ( SP to SP) – 02 Nos Make- Labotek (b) 10 KVA capacity UPS ( 3P to SP)– 03 Nos Make : Labotek (c) 15 KVA capacity UPS ( 3P to SP)– 05 Nos Make : Labotek/ Powerone (d) 20 KVA capacity UPS ( 3P to SP)– 20 Nos Make : Labotek (e) 30 KVA capacity UPS ( 3P to SP) – 05 Nos Make : Labotek (f) 20 KVA capacity UPS ( 3P to 3P ) - 02 Nos Make : Labotek (g) 30 KVA capacity UPS ( 3P to 3P) – 05 Nos Make : Labotek (h) 160 KVA capacity UPS (3P to 3P) - 1 Nos Make: Liebert
Note :- (i) The entire comprehensive maintenance of UPS system shall be carried out through OEM or one of MES approved UPS Manufacturer i.e EMERSON,TATA LIEBERT, APLAB, APC,AE . However the defective components/ parts of different UPS system shall be replaced with original existing make only.
Note :- (ii)The contractor may visit the site for inspection with services engineer of OEM/ Manufacturer of UPS system before quoting his rate.
(iii) The cost for removing and fixing of any faulty/worn parts/ components/accessories of original equipments manufacturer(OEM) such as fuses, capacitors, SC's Diodes, Logic card/PCB's swicthes, CTs Chokes, Heat sisnks, IP, O/P and control transformer, SCVS, changeover panels alarm simulation, filters, cooling fan, wheels etc or any other parts/components/accessories as required for making UPS system serviceable are deemed to be included in unit rate quoted against serial No1.
(iv) The contractor shall make the arrangement to attend the complaints of UPS on receipt at any round any complain the clock including Sunday and holiday and the cost of the same shall also deemed to be included in the rates quoted against Srl No 1. The panelty for non rectifying the complaints of UPS upto 6 hrs shall be Rs 500 and 6 hrs to 12 hrs shall be Rs 1000/- and Rs 1500/- thereafter per complaints per day .
(v) The dust cleaning shall be carried out of each UPS in a week
(vi) Maint/ repair as enumerated above shall be under taken by the manufacturer or their authorized dealer/ rep.
(vii) The cleaning of interior and exterior of system, filters, operation of cooling fan, checking of all wiring terminals, batteries connections,check the manual bypass system and normal bypass system of UPS shall be carried out of each UPS periodically.
(viii) The electric connections shall be checked regularly for looseness / tightening if required the same for un-interrupt power supply .
(ix) The contractor shall maintain a log book of each UPS system and record all the weekly/fortnightly/monthly periodical maintenance and also maintain record of all components/parts/accessories which are replaced during weekly/ fortnightly/monthly periodical maint and get signature of JE and Engr-in-Charge shall be carried out in rotation apart from breakdown for each UPS and record of the same to be maintaianed duly signed by contractor rep and MES rep.
(x) The contractor shall measure input and output phase to phase voltage, current and load and mainatin necessary records daily.
(xi) The contractor shall maintain necessary and sufficient spares have to be kept ready with them for immediate replacement at site.
Supply and installation including testing and commissioning of SMF Battery 12 Volts, 84 AH with battery copper terminals/thimples, battery inter-connection copper cable 16 Sqmm etc, complete all as directed. Make : Amaron (Quanta) / Exide Power safe / Panasonic/Firefly . Note: 1. The contractor shall furnish a 04 (Four) years replacement warranty of each battery, and the period shall be counted from the next day of actual date of completion of work. 2. An appropriate sum, equal to the amount of security deposit calculated as per scale laid down for individual securities deposit quoted amout for this item, shall be retained ,out of the final bill amount as Security Deposit , against the 04 (Four) years replacement warrenty of battery and the same shall be released only after the expiry of gurantee period. The contractor may also furnish fixed deposit receipt/BGB in lieu of the sum to be retained as security. Note - Old battery to be deposited at E/M store .
All as per item No 2 herein before but SMF Battery 12 Volts ,42 AH capacity.
All as per item No 2 herein before but SMF Battery 12 Volts ,65 AH capacity.
CHIME ELECTRONICS
LAXMI GROUP
L G BUILDERS
AMIT ASSOCIATES
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .