Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹15.4 LAccepted-AOC AT BRAJARAJPUR PO INS CHILKA DISTT KHORDA ODISHA 752037 | KHORDHA | ODISHA | 752037 | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹16.3 L+₹42,342 (2.67%)Rejected-Finance AT DUNGAMAL NH 5 PO INS CHILKA DISTT KHORDHA ODISHA 752030 | KHORDHA | ODISHA | 752030 | L2 | Rejected-Finance Other than L1 | |
| 3 | L3₹16.4 L+₹50,670 (3.19%)Rejected-Finance AT DUNGAMAL NH 5 PO INS CHILKA VIA BALUGAON DIST KHORDHA ODISHA 752037 | KHORDHA | ODISHA | 752037 | L3 | Rejected-Finance Other than L1 | |
| 4 | L4₹16.5 L+₹59,380 (3.74%)Rejected-Finance AT NUAGARH PO BARKUL DISTT KHURDHA ODISHA 752030 | KHORDHA | ODISHA | 752030 | L4 | Rejected-Finance Other than L1 | |
| 5 | L5₹16.5 L+₹66,440 (4.19%)Rejected-Finance AT BRAJARAJPUR PO INS CHILKA DISTT KHURDHA ODISHA 752037 | KHORDHA | ODISHA | 752037 | L5 | Rejected-Finance Other than L1 |
| Sl No | Description | Qty | Unit | UDAYA BHANU NAYAK L2 | BHARAT KUMAR BALL L1 | ANTARYAMI PANDA AND COMPANY L5 | SAHADEV PALAI L4 | RCB CONSTRUCTION L3 | HARI PALAI L7 | VAIKUNTHA PARIDA L6 |
|---|---|---|---|---|---|---|---|---|---|---|
| 1.00 | Taking down eaves gutters and rainwater pipes (any size or pattern), including all fittings, heads, shoes, bends, swan-necks, etc., including cleaning or refixing or removal to Store (measured overall as fixed along the centre lineover fittings and accessories)complete all as specified & directed. | 20 | RM | 88 ₹1,760 | 55 ₹1,100 Lowest | 76 ₹1,520 | 78 ₹1,560 | 75 ₹1,500 | 78 ₹1,560 | 80 ₹1,600 |
| 2.00 | S&F 75 mm dia PVC (SWR) soil, waste and vent pipes single socketed in any length with rubber ring joints, fixed to walls complete all as specified and directed | 10 | RM | 355 ₹3,550 | 350 ₹3,500 Lowest | 352 ₹3,520 | 355 ₹3,550 | 350 ₹3,500 Lowest | 355 ₹3,550 | 360 ₹3,600 |
| 3.00 | All as per item No 02 above but 110 mm dia. | 10 | RM | 450 ₹4,500 Lowest | 450 ₹4,500 Lowest | 472 ₹4,720 | 475 ₹4,750 | 470 ₹4,700 | 478 ₹4,780 | 478 ₹4,780 |
| 4.00 | S&F 75 mm bore PVC (SWR) bend any radius complete all as specified & directed. | 6 | Each | 175 ₹1,050 | 150 ₹900 Lowest | 168 ₹1,008 | 359 ₹2,154 | 165 ₹990 | 174 ₹1,044 | 170 ₹1,020 |
| 5.00 | All as per item No 04 above but 110 mm dia. | 4 | Each | 190 ₹760 | 160 ₹640 Lowest | 177 ₹708 | 172 ₹688 | 175 ₹700 | 179 ₹716 | 180 ₹720 |
| 6.00 | S&F 75 mm bore PVC (SWR) bend with access door complete all as specified & directed. | 5 | Each | 298 ₹1,490 | 180 ₹900 Lowest | 185 ₹925 | 183 ₹915 | 180 ₹900 Lowest | 188 ₹940 | 189 ₹945 |
| 7.00 | All as per item No 06 above but 110 mm dia. | 3 | Each | 345 ₹1,035 | 300 ₹900 | 299 ₹897 | 297 ₹891 | 295 ₹885 Lowest | 300 ₹900 | 360 ₹1,080 |
| 8.00 | S&F PVC (SWR) branch pieces single Y equal or unequal 75mm bore complete all as specified and directed | 2 | Each | 435 ₹870 | 350 ₹700 | 342 ₹684 | 340 ₹680 Lowest | 340 ₹680 Lowest | 355 ₹710 | 350 ₹700 |
| 9.00 | All as per item No 08 above but 110 mm dia. | 2 | Each | 291 ₹582 Lowest | 450 ₹900 | 432 ₹864 | 431 ₹862 | 430 ₹860 | 433 ₹866 | 445 ₹890 |
| 10.00 | S&F 75mm bore PVC (SWR) junction single (Single T) equal or unequal complete all as specified & directed. | 3 | Each | 430 ₹1,290 | 300 ₹900 | 292 ₹876 | 295 ₹885 | 290 ₹870 Lowest | 299 ₹897 | 300 ₹900 |
Tender Value
₹15.0 L
EMD Value
₹30,000
Closing Date
27 Jul 2026, 6:00 pmClosed
Ankit Kumar, IDSE, EE, GE Chilka
GE CHILKA, INS CHILKA, KHURDA, ODISHA 752 037
REPAIR TO INTERNAL WATER SUPPLY, CLEANING OF TANK AND CONNECTED SANITARY FITTINGS ZONE-I AREA AT INS CHILKA UNDER GE CHILKA
2026_MES_776718_1
GE/CHL/8214 OF 2026-27
Open Tender
Civil Works
Item Rate
270 days
GARRISON ENGINEER CHILKA
MES Enlisted contractor of Class E Category a(ii)
7 documents required · 7 mandatory
₹500
Yes
GE Chilka
₹30,000
Yes
25 Sept 2026
8 Jul 2026
3 Aug 2026
8 Jul 2026
27 Jul 2026
21 Jul 2026
9 Jul 2026 - 13 Jul 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Taking down eaves gutters and rainwater pipes (any size or pattern), including all fittings, heads, shoes, bends, swan-necks, etc., including cleaning or refixing or removal to Store (measured overall as fixed along the centre lineover fittings and accessories)complete all as specified & directed. | - | RM | - | - |
| - | S&F 75 mm dia PVC (SWR) soil, waste and vent pipes single socketed in any length with rubber ring joints, fixed to walls complete all as specified and directed | 10 | RM | - | - |
| - | All as per item No 02 above but 110 mm dia. | 10 | RM | - | - |
| - | S&F 75 mm bore PVC (SWR) bend any radius complete all as specified & directed. | 6 | Each | - | - |
| - | All as per item No 04 above but 110 mm dia. | 4 | Each | - | - |
| - | S&F 75 mm bore PVC (SWR) bend with access door complete all as specified & directed. | 5 | Each | - | - |
| - | All as per item No 06 above but 110 mm dia. | 3 | Each | - | - |
| - | S&F PVC (SWR) branch pieces single Y equal or unequal 75mm bore complete all as specified and directed | 2 | Each | - | - |
| - | All as per item No 08 above but 110 mm dia. | 2 | Each | - | - |
| - | S&F 75mm bore PVC (SWR) junction single (Single T) equal or unequal complete all as specified & directed. | 3 | Each | - | - |
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.20 MB
8114tenderpage.pdf
Tender Documents • 0.65 MB
BOQ_870496.xls
BOQ • 2.43 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .