Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹30.6 LAccepted-AOC 1 225 5 6 SADAR BAZAR DELHI CANTT 110010 | NEW DELHI | DELHI | 110010 | L-1 | Accepted-AOC L-1 | |
| 2 | L-2₹32.5 L+₹58,026.50 (1.82%)Rejected-AOC RZ A2 2 CHANAKYA PLACE PART I OPP C 1A BLOCK JANAK PURI NEW DELHI 110059 | NEW DELHI | WEST DELHI | DELHI | 110059 | L-2 | Rejected-AOC L-2 |
Tender Value
Refer Docs
EMD Value
₹93,600
Closing Date
13 Sept 2023, 6:00 pmClosed
GE I RND DELHI
MILITARY ENGINEER SERVICE, GARRISON ENGINEER (I) RND, LUCKNOW ROAD, TIMARPUR, DELHI-110054
REPAIR/MAINTENANCE OF PACKAGE TYPE UNIT TR VRF EQUIPMENT OF 22 TR AND REPAIR/MAINT OF COOLING APPLIANCES INSTALLED IN SSPL UNDER GE (I) RnD DELHI
2023_MES_612196_1
GE/RND-51/DLI/2023-2024
Open Tender
Civil Works
Item Rate
330 days
Delhi
Class-D, Cat-c(i)
2 documents required · 2 mandatory
₹500
GE I RND DELHI
₹93,600
Yes
29 Nov 2023
4 Aug 2023
16 Sept 2023
4 Aug 2023
13 Sept 2023
25 Aug 2023
Amount
M&L for charging of Refrigerant R-22 complete including testing complete all as specified and directed.
M&L for charging of Refrigerant R-32 complete including testing complete all as specified and directed.
M&L for charging of Refrigerant R-410A including testing complete all as specified and directed.
M&L for repair to leakage including brazing, Nitrogen gas testing by holding the pressure for minimum 24 hours and recommissioning of 22 TR VRF Unit complete all as specified and directed.
All as per item Ser No. 4.00 above but 5 TR.
S&F in repair refrigerant copper pipe 15.88 mm dia, 1.25 mm wall thickness complete all as specified and directed.
S&F in repair refrigerant copper pipe 12.70 mm dia, 1.25 mm wall thickness complete all as specified and directed.
S&F in repair refrigerant copper pipe 5/8" (15.88 mm) dia 1.25 mm thick including foam insulation for copper tube wall complete all as specified and directed.
S&F in repair refrigerant copper pipe 3/8" (9.52 mm) dia 1.25 mm thick including foam insulation for copper tube wall complete all as specified and directed.
Comprehensive, preventive and periodical maintenance of VRF (Make: MITSUBISHI) by Inspecting the plant system and carry out quarterly inspection as a part of preventive maintenance with relevant Per Month checklists, Checking the refrigeration system, motor and starters and ensuring healthy condition of the plant, Checking the system for any leakage and rectification of leakage found, Taking set of readings and evaluating to ensure satisfactory performance of the plant, Checking the Refrigeration control system for operation and adjusting the settings, Checking the functioning of compressors and its accessories, Cleaning the IDU evaporator ODU condenser coils once in a Contract Period as per direction of Engineer-in-Charge, Lubricating the bearings of motors, & fans when found necessary, Quarterly inspection of belts adjusting the tension and replacing the worn out belt as and when found required, Replenishment of refrigeration gas as a result of fare wear and tear, Overhauling the components of the equipment at site or in service station as and when required, Checking of the microprocessors PCBs and sensors of IDU/ODU units for its proper functioning and repair replacement of the same if found necessary, Attending to complaint and breakdown calls whenever required, Carrying out external cleaning (chemical or with water of condensor coils of outdoor unit,Reporting the healthiness of the plant and suggesting improvements if any complete all as specified and directed.
Note :- (i) The tenderer shall have to replace the unserviceable material with OEM material only. Minor replaced parts shall deemed to be included in quoted rate, however the cost of replaced major spare parts will be paid and measured seperatly. Old material will be contractor's property and credit included in the rate quoted. (ii) In case any accident occur of any individual like Mechanic/Helpers/users during maintenance/operation of above mentioned Airconditioner/unit, contractor is liable to pay compensation to the individual as decided by the competent authority. Principal Employer will not be responsible for the same. (iii) If complaint is not attended by contractor with in 24 Hours, (except major repairs in the openion of Engr-in-Charge) the penality of Rs 1000/ per day to be imposed and amount of penality will be deducted from RAR or any dues and in the mean time, if complaint is get rectified by the deptt by other means, the panelty of twice of recitification cost shall be made from contractor dues and the decesion of GE in this regard shall be final & binding and no representation what soever shall be entertained. (iv) The cost of transportation (to and from) for all kind of necessary equipment / T&P shall be arranged/brought by contractor to complete the job at site , stationary for maintenance of record, no extra cost shall be paid to the contractor to this effect. (v) Complaint shall be lodged by telephonically ,so contractor to specify the telephone no who will receive the complaint round the clock. After attending the complaint contractor will obtain the signature from rep of User/JE/Engineer-in-Charge every day as a token of complaint attended. (vi) The Schedule 'A'/BOQ consists of Comprehensive, preventive and periodical maintenance of VRF (Make: MISTUBISHI ELECTRIC) Under GE (I) R&D Delhi
(vii) The work shall be carried out through authorized dealer/ repairer of M/s MITSUBISHI ELECTRIC only all as described in schedule 'A'/ BOQ, special conditions, particular specification, MES SSR and as directed by GE/Engineer-in-charge. Comprehensive and preventive maintenance shall be carried out by contractor through trained Engineer of M/s MITSUBISHI ELECTRIC only. (viii) Contractor shall submit MOU within 07 days from date of letter of issue of acceptence of contract, failing which late charges @0.5% OF CA amount per week from date of acceptance shall be imposed on contractor. The contract shall be liable to be cancelled without any notice under condition 54 of IAFW 2249, if MoU not submitted by Contractor within 5 week of acceptance. On occassion to this Performance Security @ 5% shall be forfeited by Department and work may be get executed under other means. Any Condonation of delay will be adjudicated by the Accepting Officer only. No extension will be granted on the part of OEM causing delay in signing the MoU with Contractor.
S&F in repair outdoor PCB suitable for Package type AC plant 5 TR complete all as specified and directed.
S&F in repair indoor PCB suitable for Package type AC plant 5 TR complete all as specified and directed.
M&L for Soft Chemical servicing of 05 TR package type AC Plant indoor Units including minor parts complete all as specified and directed.
M&L for Soft Chemical servicing of 05 TR package type AC Plant Outdoor Units including minor parts complete all as specified and directed.
M&L for Servicing of the window AC 1.5/2 ton capacity of any make, including oiling/greasing the blower motor, cleaning the evaporator condenser coils externally to remove the dust, replacement of defective thimbles etc and re-fixing the air conditioner at its original position by the experienced refrigeration mechanic complete all as specified and directed. Note :- (i) Any unserviceable spare parts & gas charging required to be replaced shall be measured & paid separately under respective item. (ii) The cost of dismantling, taking out window AC 1.5/2.0 ton from window and shifting to location where directed for proper washing and servicing and refixing the same shall deemed to be included in unit rate quoted.
All as per item Ser No. 15.00 above but for split type AC/Inverter type/casette type AC 1.5/2.0/4.1 Ton.
M&L in repair Fan Motor of AC (Window/ Split Type) 1.5 TR Capacity of approved Make and required Size to suit existing AC complete all as specified and directed.
All as per item Ser No 17.00 above but AC (Window/Split Type). 2.0 TR Capacity
M&L for rewinding of Fan Motor of AC 1.5/2.00 TR Capacity, (Window/Split Type) of any Make with Super Enameled Copper Wire of appropriate Gauge and Quantity including taking out burnt Winding, complete all as specified and directed.
M&L in repair Air Circular Blower Fan Motor of AC (Split Type), 1.5 TR/2.0 TR Capacity complete all as specified and directed.
M&L in repair Air Filter suitable of AC (Window type) 1.5 TR/2.0 TR Capacity complete all as specified and directed.
M&L in repair Air Filter suitable for AC (Split type) 1.5 TR/2.0 TR Capacity complete all as specified and directed.
M&L in repair Capacitor Running 36 mfd – 45 mfd suitable for new/star rated for AC (Window/Split Type) 1.5 TR/2.0 TR Capacity complete all as specified and directed.
M&L in repair Capacitor Starting 80 mfd – 120 mfd suitable for old ones AC (Window/Split Type) 1.5 TR/2.0 TR Capacity complete all as specified and directed.
S&F in repair Fan Motor Capacitor 4 mfd of suitable for new/star rated AC (Window/Split Type) 1.5/2.0TR capacity complete all as specified and directed.
S&F in repair Fan Motor Capacitor 6 mfd suitable for old ones AC (Window/Split Type) 1.5/2.0TR capacity complete all as specified and directed.
S&F in repair Fan Motor Blades AC (Window/Split type) 1.5/2.0 TR capacity complete all as specified and directed.
S&F in repair Front Plastic Grill of AC (Window type) 1.5 TR/2.0 TR Capacity all as per existing and complete all as specified and directed.
S&F in repair Front Plastic Grill for inner unit of AC (Split type) 1.5 TR/2.0 TR Capacity all as per existing complete all as specified and directed.
M&L in repair Runner for air blower motor of AC (split type) AC 1.5/2.00TR capacity as per site requirement) all as per existing complete all as specified and directed.
M&L in repair Single Pole Contactor 25A Capacity, MR 11W type as approved suitable for AC (Split Type) complete all as specified and directed.
M&L in repair Starting Relay of AC (Window/Split Type) 1.5 TR/2.0 TR Capacity complete all as specified and directed.
M&L in repair Strainer with Capillary Tube of AC Window/ Split Type) 1.5 /2.0 TR Capacity complete all as specified and directed.
M&L in repair Thermostat Switch of AC (Window/Split Type) 1.5 TR/2.0 TR Capacity complete all as specified and directed.
S&F in repair cooling coil suitable for window type room AC 1.5/2 TR Capacity complete all as specified and directed.
S&F in repair Condensing coil suitable for window type AC 1.5/ 2 ton Capacity complete all as specified and directed.
S&F in repair Condensing coil suitable for split type AC of Capacity 2 ton complete all as specified and directed.
S&F in repair cooling coil suitable for split type AC of Capacity 2 ton complete all as specified and directed.
S&F in repair Indoor unit suitable for 1.5 TR split type AC as per existing complete all as specified and directed.
S&F in repair outdoor unit suitable for 1.5 TR split type AC without compressor as per existing complete all as specified and directed.
S&F in repair Indoor unit suitable for 2 TR split type AC as per existing complete all as specified and directed.
S&F in repair outdoor unit suitable for 2 TR split type AC without compressor as per existing complete all as specified and directed.
S&F in repair Hermatically sealed unit compressor for split/ window type AC of capacity 1.5 Ton as per existing complete all as specified and directed.
All as per item Ser No . 45.00 above but of split/ window type AC, capacity 2.0 Ton.
Taking down/up defective AC 1.5 TR Capacity (Window/Split Type), Transportation from MES Store Yard/Site to Workshop and Back including re-fixing /re-installing after taking out defective/burnt Compressor Sealed Unit and providing new Compressor Rotary/ Reciprocating as per site requirment of same Capacity from Authorised Dealer including Flushing of Condenser and Charging with required quantity of appropriate Refrigerant Gas R22/R410 including reconnection of electric connections, functioning AC in all respect and testing, complete all as specified and directed.
All as per Item Ser No. 47.00 above, but AC 2.0 TR Capacity (Window/Split Type).
M&L in repair PCB with remote for window type AC up to 2 Ton capacity complete all as specified and directed .
M&L in repair PCB with remote for Split type AC 2/3(1.5x2) Ton capacity complete all as specified and directed .
M&L in repair PCB & motherboard with remote complete set for Inverter Split type AC up to 2 Ton capacity complete all as specified and directed .
M&L in repair Remote of AC ( Window/Split Type) 1.5/2.0 TR capacity suitable to existing AC (as per sample or as per site requirement) including cells/Battery complete all as specified and directed.
S&F in repair wiring kit suitable for 1.5 to 2.0 ton capacity AC complete complete all as specified and directed.
S&F in repair gas charging pin valve complete complete all as specified and directed.
Taking out window type AC complete unit from any height/ any floor up to four storey building and shifting to another location in the same or other building in the complex including refixing of the unit with required electrical connection & testing complete all as specified and directed.
Taking out split type AC complete indoor and outdoor unit from any height/ any floor up to four storey building by including pumping down the gas into the compressor by controlling the suction and discharge valves , disconnecting the suction and dischagre copper piping and shifting to another locatiion in the same or other building in the complex including refixing of the unit with required electrical connection & testing complete all as specified and directed.
S&F in replacement of casing of window type AC including company fitted condensing & cooling coil complete including PCB except compressor as per existing complete all as specified and directed.
M&L in replacement of split valve ¼” for split AC up to 2.00 ton capacity complete all as specified and directed.
All as per item Ser No. 58.00 above but 1/2".
S&F in replacement compressor shut off valve 3/8" for split AC up to 2.00 ton capacity complete all as specified and directed.
S&F in replacement compressor shut off valve 5/8" for split AC up to 2.00 ton capacity complete all as specified and directed.
S&F in replacement of electrolyte grade copper tubing of size 1/4" dia, having wall thickness 0.89mm suitable for any type of split type AC including synthetic rubber foam complete all as specified and directed. Note : - The quoted rate is inclusive of necessary T&P, Rope, Ladder etc with safety equipment for execution the work upto six stories building complete.
All as per item ser No. 62.00 above but size 1/2" dia, having wall thickness 1.25mm.
All as per item ser No. 62.00 above but size 3/8" dia, having wall thickness 1.25mm.
All as per item ser No. 62.00 above but size 5/8" dia, having wall thickness 1.25mm.
S&F in replacement PVC conduit 20mm dia including all clamps & accessories and connecting the condensate pipe of ACs to this conduit for proper drainout of condensate water from ACs of Bldgs upto 5 (five) storey complete all as specified and directed.
S&F in replacement PVC conduit 25mm dia including all clamps & accessories and connecting the condensate pipe of ACs to this conduit for proper drainout of condensate water from Acs of Bldgs upto 5 (five) storey complete all as specified and directed.
S&F in replacement Hermatically Sealed compressor for 40/80 Ltrs capacity water cooler including bracing the suction and discharge lines as per existing complete all as specified and directed.
S&F in replacement Hermatically Sealed compressor for 60/120 Ltrs capacity water cooler including bracing the suction and discharge lines as per existing complete all as specified and directed.
S&F in replacement metal plug top 2 pole and earth, 20 Amps, 240 volts suitalbe for sheet metal enslousers complete all as specified and directed.
S&F in repalcement metal enclosures with clad socket & plug top 2 pole and earth, including of MCB SP 25 Amps 240 volts complete all as specified and directed.
S&F in replacement of PVC FRLS insulated flexible copper conductor 3 core 1100 volts grade of size 2.50 Sqmm complete all as specified and directed.
S&F in replacement of PVC FRLS insulated flexible copper conductor cable 1100 volts grade, 3 core of size 1.5 Sqmm complete all as specified and directed.
M&L in replacement submain wiring including PVC casing caping with all accessories, with 2 run of 4.00 Sqmm cable PVC insulated copper conductor multi - stranded FRLS cable including 4.0 Sqmm multi stranded copper conductor cable PVC FRLS insulated unsheathed for earth continuity connected to common earth dolly and complete all as specified and directed.
S&F in replacement AC stand suitable for out door AC unit up to capacity of 2 ton, made out of 40x40x6mm angle iron including fixing arrangements like welding, fabrication and nuts & bolts etc upto six stories building complete all as specified and directed. Note :- Dismensions & Design shall be as approved by Engineer-in-Charge.
S&F in replacement reverse valve system made out of copper for heating option suitable for 1.5/2.0 ton split / window type AC including appropriate Gas Charging complete all as specified and directed.
M&L for servicing of water cooler of any capacity including cleaning of water cooler from inside and outside with potassium permanganate, servicing of cooling coil, fan, motor, condensor, fan blades and its connected water and refrigerant fittings complete all as specified and directed.
Supply and charging the gas in the water cooler of any make and capacity up to 150 ltr capacity including testing and detecting leakage if any with nitrogen gas and vaccum the system after rectification of all leakages complete all as specifie and directed.
S&F in replacement thermostat switch suitalbe for water cooler of any make & size complete all as specified and directed.
S&F in replacement starting relay/over load relay suitalbe for water cooler of any make & size complete all as specified and directed.
S&F in replacement push cock 15 mm bore chromium plated heavy duty suitable for water cooler of any make and capacity complete all as specified and directed.
M&L for preparation of old painted surfaces of water cooler by removing old deteriorated paint, making surfaces smooth and applying two coats of synthetic enamel paint over a coat of red oxide primer by spray painting complete all as specified and directed.
S&F in replacement fan motor ISI marked suitalbe for water cooler as per existing capacity upto 150 ltrs complete all as specified and directed.
S&F in replacement of condenser fan suitable for water cooler upto 150 ltrs capacity complete all as specified and directed.
S&F in replacement 15 mm dia PVC connection of length upto 600mm with PTMT nuts on both ends complete all as specified and directed.
S&F in replacement condenser coil suitable for water cooler upto 150 ltrs capacity complete all as specifed and directed.
S&F in replacement steel/aluminium waste water tray suitable for water cooler upto 150 ltrs capacity complete all as specifed and directed.
M&L for servicing of desert cooler of any size including cleaning of desert cooler from inside & outside, greasing of fan kit, motor, water pump and connected accessories complete all as specified and directed.
M&L for painting of desert cooler capacity upto 4000 Cfm with two coats of approved synthetic enamel paint inside & outside including fan/fan blade/brackets after scrapping the rust,peal of paint and preparation of surface complete all as specified and directed. Note :- The rates are inclusive of taking down cooler from any height, removal to workshop for painiting and refixing in position after painting.
S&F in replacement of desert cooler submersible water pump complete with electric motor single phase 230 volts 50Hz including lead, connecting & testing as per sample complete all as specified and directed.
S&F in replacement desert cooler fan motor,copper wound suitable for upto 450mm sweep SP 230 volts 50HZ including legs, rubber bush nuts/bolts for fixing of fan motor complete with connection & testing complete all as specified and directed.
S&F in repalcement of commercial ply wood BWP 4mm thick ISI marked, any size to close the opening between desert cooler grill and window complete all as specified and directed.
S&F in replacement plug top 3 pin 5 Amps complete all as specified and directed.
S&F in replacement plug top 3 pin 15 Amps complete all as specified and directed.
S&F in replacement motor capacitor 2.5/3.15/4 mfd complete all as specified and directed.
S&F in replacement front grill made out of mild steel complete with air guide vanes suitable for desert cooler of capacity 4000 Cfm complete all as specified and directed.
S&F in replacement of body without side panels made out of galvanised iron sheets of 22 gauge for bottom tank & 20 gauge for top cover of desert cooler, body duly painted with one coat of red-oxide primer & 2 coat of synthetic enameled paint approx size 0.50mx0.50m complete with fixing of all spare complete all as specified and directed.
S&F in replacement of side panels of desert cooler body of 22 gauge of existing size & shape duly painted with a red-oxide primer & 2 coat of synthetic enameled paint complete with fixing of all spare approx size 0.40mx0.50m complete all as specified and directed.
S&F in replacement float valve assembly with PTMT ferrule 15 mm dia and PVC ball valve suitable for water cooler up to 150 ltrs capacity and desert cooler upto 4000 Cfm complete all as specified and directed.
S&F in replacement new wood wool pad, (Khus Khus) pad, set of three covered by GI wire mesh suitable for desert cooler complete all as specifed & directed
M&L for replacement of aluminium multi wing Fan blade, best quality as per existing type and size suitable for desert cooler complete all as specifed and directed
Taking down ceiling fan/exhaust/pedestal/table/air circulating fan of any size or make by disconnecting eletric connection and removing from site for rewinding/ overhauling/ engrawing of MES No of fans and fixing the same in eixsting position or as directed with eletric connection and testing complete all as specified and directed
M&L for overhauling of ceiling fan/pedestal/exhaust/table/air circulating fan of any size or make opening the fan motor, overhauling by removing dust from field coils including varnishing of field coils and greasing of motor with superior qauality grease for smooth running inlcuding cleaning and washing the blades and assembling of fan motor and refixing at the same place complete all as specified and directed.
M&L for removing of burnt out winding wire from ceiling fan of any make of size 1200/1400 mm sweep including cleaning of slots etc and rewinding with super enameled copper winding wire as per existing size/gauge including insulating material and varnishing complete all as specified and directed.
All as per item Ser No 105.00 above but for exhaust fans of size 225 mm sweep to 380 mm sweep
All as per item Ser No 105.00 above but for exhaust fan of size 450 mm sweep
All as per item Ser No 105.00 above but for pedestal fan/Air circulator fan of size 400 mm to 600 mm sweep.
All as per item Ser No 105.00 above but for table fan/wall mounted of 400 mm sweep
M&L for replacement of defective ball bearing for ceilng/table/pedestal/Air-circulators fan of any size complete all as specified and directed.
All as per item Ser No 110.00 above but for exhaust fan upto 450mm size.
M&L for replacement of rubber seal of suitable size for ceiling fan complete all as specified and directed
M&L for replacement of gun metal bush suitable for any type/model/size of fans complete all as specified and directed.
M&L in replacement of ceiling fan regulator five step 60/120 watt electronic type AC 230/240 Volts suitable for 1200/1400 mm sweep complete with all fixing accessories including necessary electric connection complete all as specified and directed.
M&L for painting of ceiling fans any make and size at site with one coat of superior quality synthetic enameled paint of approved make & colour by spraying after filling cavities with filler and preparation of surface complete all as specified and directed.
All as per item Ser No 115.00 above but exhaust fan of size 250/300 mm sweep.
All as per item Ser No 115.00 avove but for exhaust fan of size 450 mm sweep
S&F in replacement voltage stabilizer 4 KVA, suitable for window/split type AC of capacity upto 1.5 TR working on AC 240 V, 50Hz, single phase complete all as specified and directed.
S&F in replacement voltage stabilizer 5 KVA, suitable for window/split type AC of capacity upto 2 TR working on AC 240 V, 50Hz, single phase complete all as specified and directed.
S&F in replacement Pedestal fan 450mm sweep working on AC 240 V,50Hz, single phase complete all as specified and directed. Note: Old unserviceable fan shall be deposited to E/M store yard and taken on charge by the deptt.
S&F in replacement exhaust fan PVC body 250mm sweep working on AC 240 V,50Hz, single phase complete all as specified and directed. Note: Old unserviceable fan shall be deposited to E/M store yard and taken on charge by the deptt.
Taking down geyser of capacity 25 ltrs after dissconnecting the water and electric connections etc and replaceing the stainless steel tank with assembly to make the geyser fully functional and refixing the same at its orignal position complete all as specified and directed.
All as per item ser No. 122.00 above but capacity 50 ltrs.
S&F in replacement of Heating element triangle/round type as per existing of capacity 1.5KW of Hot appliances complete all as specified and directed. .
All as per item ser No. 124.00 above but capacity 2KW.
S&F in replacement of thermostate as per existing of capacity 25/50 ltrs of Hot appliances complete all as specified and directed. .
S&F in replacement of shut off valve as per existing of capacity 25/50 ltrs of Hot appliances complete all as specified and directed. .
Material and Labour in replacement earthing complete with GI earth plate electrode 600mmx600mmx6mm thick burried in ground vertically to a depth not less than 2.25meters below ground level with top edge of the earth plate at a depth not lesss than 1.5 meter below the ground level, earth plate surrounded 15cm thick layers of common salt and charcoal dust starting from ground below and above 15 cm of earth plate. GI plate connected with galvanised iron strip of 25 x 4mm by means of Copper nuts, bolts and washers. Strip laid in 40mm dia light grade GI pipe as protection from top of the plate up to test point (cost of protection pipe up to 7.5 meters from earth electrode will be included in the rates quoted by the contractor) with following:- (a) GI strip of size 25mm x 4mm. (b) Watering pipe GI light grade 20mm dia from top of the earth electrode up to MS funnel with wire mesh embeded in floor of PCC (1:2:4 type B-1, using 20mm graded stone aggregate) earth pit. (GI Funnel should properly tightned on GI watering pipe and embeded in PCC floor of earth pit with open top suitable for watering of earth pits) (c) PCC earth pit 30x30x30cm internal dimension constructed in PCC 1:2:4 type B1 (using 20mm graded stone aggregate), exposed surfaces smoothly finished with 15mm thick cement mortar 1:6 plaster including RCC 1 :2:4 type B0, reinforced with 8mm dia deformed bars @100 mmc/c bothways pit cover 25mm thick with 2 Nos MS handles of 12mm dia bar suitable for carrying of pit cover. (d) Angle iron frame made out of 40x40x4 mm for 30x30 cm PCC pit for holding the pit cover. (e) Apply two coat of synthetic enamel paint over one coat of red oxide primer on exposed steel surfaces and two coat of hot tar on embedded portion of steel surfaces.
S&F in replacement of Thermo insulation glass wool as per existing of capacity 25/50 ltrs of Hot appliances complete all as specified and directed.
S&F in replacement of water connection CP for inlet & outlet (Hot & Cold) as per existing of capacity 25/50 ltrs of Hot appliances 600mm length complete all as specified and directed.
S&F in repair switch piano type 5 A SP one way complete all as specified and directed.
S&F in repair switch piano type 5 A SP two way complete all as specified and directed.
S&F in repair bell push piano type 5 A complete all as specified and directed.
S&F in repair socket outlet 5 pin 5 A flush type complete all as specified and directed.
S&F in repair of Switch socket combination 2 in 1, 3 pin, 5 and 15 amp flush type universal complete all as specified and directed.
S&F in repair of Ceiling fan regulator electronic, step type, 120 watts 2 module complete all as specified and directed.
S&F in repair of bell ding Dong AC 230 vols, single pole complete all as specified and directed.
S&F in repair of thermostat cut off cut in range 0-75 degree centigrade AC 230 V suitable for storage type geyser 25 ltr capacity complete all as specified and directed..
S&F in repair of thermostat cut off cut in range 0-75 degree centigrade AC 230 V suitable for storage type geyser 50 ltr capacity complete all as specified and directed..
S&F in repair of white hylam sheet of size 10" x 8" x 2 mm thickness including brass nut and washer fixing on wall complete all as specified and directed.
S&F in repair of white hylam sheet of size 6" x 4 " x 2 mm thickness including brass nut and washer fixing on wall complete all as specified and directed.
S&F in repair of PVC rectangular block for mounting, switches, sockets, fan regulator etc with 3 mm thick plastic laminated sheet cover of size 100 mm x 100 mm and 50 mm deep including brass nut & washer complete all as specified and directed.
S&F in repair of white cover plate with frame 2 module complete all as specified and directed.
S&F in repair of white cover plate with frame 4 module complete all as specified and directed.
S&F in repair of modular metal flush box 2 module complete all as specified and directed.
S&F in repair of modular metal flush box 4 module complete all as specified and directed.
Note for all items :- 1. The contractor's site supevisor/site engineer shall be report at 0900 hrs daily excluding Sunday & holiday to collect the complaints/job card & complete the same complaint provided by JE E/M within 48 hours 2. If the complaints are not attended within stipulated time period, contractor shall be liable for recovery as follows: - (a) After 48 Hrs, Rs - 1000.00 Per complaint per day. 3. The technicians for repair of summer appliances can be called during non-working days/hrs (i.e. Sunday, Holidays & after working hrs) for any vital complaint at DRDO area and quoted rates are deemed to be included for this aspect and nothing extra shall be admissible on this account. 4. The contractor has to produce job card duly signed by user & JE E/M to Engineer-in-charge.
S&F in replacement LED surface mounting panel 2'×2' fitting 36W and making all electric connections and including twin core 1.5 sqmm flexible copper cable for connecting to ceiling rose complete all as specified and directed.
M&L in replacement of sub main wiring with two run of single core PVC insulated FRLSH stranded copper conductor cable of size 4 Sq mm and one run of 4 Sq mm PVC insulated FRLSH copper conductor cable as earth continuity conductor drawn in and including non metallic rigid 25 mm dia PVC conduit concealed complete all as specified and directed.
M&L in repair MS chequred plate of suitable size for cable duct cover, 6mm thick and earth pit cover complete all as specified and directed.
S&F in repair synthetic insulating mat of size 2m x 1m x 25mm thick for voltage upto 11 KV complete all as specified and directed.
S&F in repair Capacitor Bank MPP-H, 5 KVAR capacity rated 440 Volts AC,3ø,50HZ ,Delta connection, Round type complete all as specified and directed.
S&F in repair Capacitor Bank MPP-H, 10 KVAR capacity rated 440 Volts AC,3ø,50HZ ,Delta connection, Round type complete all as specified and directed.
S&F in repair Capacitor Bank MPP-H, 20 KVAR capacity rated 440 Volts AC,3ø,50HZ ,Delta connection, Round type complete all as specified and directed.
S&F in repair Capacitor Bank MPP-H, 25 KVAR capacity rated 440 Volts AC,3ø,50HZ ,Delta connection, Round type complete all as specified and directed.
S&F in replacement of 3 Pole MCCB, 250 Amp, 50 Hz, 415 V with rupturing capacity 35 KA complete all as specified and directed.
S&F in replacement of 3 Pole MCCB, 400 Amp, 50 Hz, 415 V with rupturing capacity 36 KA complete all as specified and directed.
S&F in replacement of 3 Pole MCCB, 630 Amp, 50 Hz, 415 V with rupturing capacity 50 KA complete all as specified and directed.
S&F in replacement of 4 Pole MCCB, 250 Amp, 50 Hz, 415 V with rupturing capacity 35 KA complete all as specified and directed.
S&F in replacement of 4 Pole MCCB, 400 Amp, 50 Hz, 415 V with rupturing capacity 36 KA complete all as specified and directed.
S&F in replacement LED 18 Watt fitting batten with decorative end cap complete with aluminium housing & integral electronic driver with tube 20 watt complete incl connection with 1.5 Sqmm 2 core flexible copper cable complete all as specified and directed.
S&F in replacement LED 20 Watt fitting batten with decorative end cap complete with aluminium housing & integral electronic driver with tube 20 watt complete incl connection with 1.5 Sqmm 2 core flexible copper cable complete all as specified and directed.
M&L for Cleaning of outdoor units of 22TR outdoor unit with soft chemical and corrasion protection with Nanova care coat of ACX-4000 ultracore or equivalent to increase the outdoor life complete all as specified and directed.
M&L for Cleaning of Indoor units of 22TR outdoor unit with soft chemical and corrasion protection with Nanova care coat of ACX-4000 ultracore or equivalent to increase the indoor life complete all as specified and directed.
M&L for Cleaning of cooper pipe of different sizes upto 40mm dia and corrasion protection with Nanova care coat of ACX-4000 ultracore or equivalent complete all as specified and directed.
S&F in repair manually change over switch of 800 amps 415 V with sheet steel inclosures, mounting on wall including fiting accessories complete all as specified and directed.
RUCHIKA ENGG.WORKS
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .