Loading…
Loading…
| # | Company | Amount |
|---|---|---|
| 1 | ₹3.0 L 239 2ND FLOOR SPAZEDGE TOWER B SECTOR 47 SOHNA ROAD HARYANA 122018 | ₹3.0 L |
Tender Value
₹39.8 L
EMD Value
₹39,772
Closing Date
30 May 2024, 11:00 amClosed
Civil, Electrical work, roof sheet, kitchen work etc
NSL/CEO/IIPA/NIT/2024/663
NSL/CEO/IIPA/NIT/2024/663
Open Tender-Domestic
Miscellaneous
New Delhi, Delhi
₹2,950
₹39,772
28 Jul 2026
22 May 2024
30 May 2024
30 May 2024
12 Jun 2024
S NO DESCRIPTION AMOUNT AMOUNT
Renovation and Restoration Works of
Canteen (Ground floor) at IIPA, New Delhi
2.00 ELECTRICAL WORKS 2,25,500.00 4,05,501.00
Renovation and Restoration Works of lift
B side Corridor (Ground floor) at IIPA, New
2.00 ELECTRICAL WORKS 1,99,480.00 57,240.00
Total (DSR +MR) 39,77,187.00
Digitally signed by AMIT
RENOVATION WORKS AT IIPA, NEW DELHI - CANTEEN (GOUND FLOOR)
S.No. DESCRIPTION UNIT QTY DSR RATE DSR AMOUNT NDSR RATE NDSR AMOUNT
Demolishing brick work manually / by mechanical means including stacking
1 15.7 of serviceable material and disposal of unserviceable material within 50
metres lead as per direction of Engineer-in-Charge.
15.7.4 In cement mortar CUM 2.00 2,060.20 4,120.40
Removal of existing exhasut fan and stacking it in location specified by the
client within the premises.
Half brick masonry with common burnt clay F.P.S. (non modular) bricks of
class designation 7.5 in superstructure above plinth level up to floor V level.
6.13.2 Cement mortar 1:4 (1 cement :4 coarse sand) SQM 5.00 1,123.80 5,619.00
CEMENT PLASTER :- 15 mm cement plaster on the rough side of single or
half brick wall of mix.
Polishing of existing granite flooring to achive glossy finish or as specified
Polishing and buffing on marble work/Granite work/stone dado work where
ever required to give gloss finish complete.
Steel work welded in built up sections/ framed work, including cutting,
7 10.25 hoisting, fixing in position and applying a priming coat of approved steel
primer using structural steel etc. as required.
In gratings, frames, guard bar, ladder, railings, brackets, gates and similar
Providing and supplying aluminium extruded tubular and other aluminium
sections as per the architectural drawings and approved shop drawings ,
the aluminium quality as per grade 6063 T5 or T6 as per BS 1474,including
super durable powder coating of 60-80 microns conforming to AAMA 2604
8 25.1 of required colour and shade as approved by the Engineer-in-Charge. ( The kg 200.68 414.30 83,142.97
item includes cost of material such as cleats, sleeves, screws etc.
necessary for fabrication of extruded aluminium frame work. Nothing extra
shall be paid on this account). The weight of aluminium extruded section
shall be taken for purpose of payment.
Supply and installation of Wall Panelling with 6 mm thk HPL(High Pressure
Laminate) Quality panels of standard size (1300 X 2800 mm)with both side
décor.The material should be have Non-fading high performance acrylic
polyurethane surface technology) conforming to ISI norms with CE Mark.
Panels are double hardened including acrylic polyurethane resin which is
thermally cured under high pressure.Installation of HPL panels will be done
by 3M Adhesive tape in any direction as per insruction of Site Engineer(with
Fixed and Sliding Points) with minimum recommended Aluminum section
of 100 x50 x 2 mm thick and L section 50 x 50 x 2mm thick held by Wall
Bracket with Wind load and Dead load slot as per design, anchored by
standard Hilti/Fischer or equivalent make anchor fasteners a.completed as
per manufacture specification/EIC. If
Digitally signed by AMIT
S.No. DESCRIPTION UNIT QTY DSR RATE DSR AMOUNT NDSR RATE NDSR AMOUNT
Providing and fixing double scaffolding system (cup lock type) on the
exterior side of building/structure, upto 25 metre height, above ground level,
including additional rows of scaffolding in stepped manner as per
requirement of site, made with 40mm dia M.S. tube, placed 1.5 metre
centre to centre, horizontal & vertical tubes joint with cup & lock system with
M.S. Tubes, M.S. tube challis, M.S. clamps and staircase system in the
scaffolding for working platform etc. and maintaining it in a serviceable
10 24.2 condition for execution of work of cleaning and/ or pointing and/ or applying sqm 555.00 338.25 1,87,728.75
chemical and removing it thereafter. The scaffolding system shall be
stiffened with bracings, runners, connecting with the building etc, wherever
required, if feasible, for inspection of work at required locations with
essential safety features for the workmen etc., complete as per directions
and approval of Engineer-in-charge. Note:- (1) The elevational area of the
scaffolding shall be measured for payment purpose. (2) The payment will
be made once only for execution of all items for such works.
Providing and fixing 6mm thick poly-carbonate sheet with 40% transparency
as per vendor and to be matched with existing on roof sheet of the atrium
including cost of removing of existing roof sheet and dumping/ storing the
same as per instruction of Project in charge, including cost of all necessary
fixing arrangement, framing wherever required complete with all respect as
per manufacturer details and specification and instruction of Project in
charge/ Architect. The cost to include dismantalling of existing roof sheet
and disposing it to nearest duping yard.
SITC of wood grain finish GI baffles of size 50mm x 150mm @ 150mm-
12 MR 200mm C/C including suspending channels and all other accessories as sqm 80.00 11,200.22 8,96,017.73
required complete.
Wall painting with acrylic emulsion paint, having VOC content less that 50
13 13.82 grams / litre, of approved brand and manufacture, including appliying
additional coats wherever required, to achive even shade and colour.
Painting with synthetic enamel paint of approved brand and manufacture to
give an even shade:
Two or more coats on new work over an under coat of suitable shade with
ordinary paint of approved brand and manufacture:-
15 MR Providing and installing of kitchen hood Nos 2.00 50,000.37 1,00,000.74
Supply, installation, balancing and commissioning of factory fabricated
E&M GSS sheet metal rectangular/round ducting complete with
16 2022 neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers,
16.12.1 supports etc. as per approved drawings and specifications of
following sheet thickness complete as required.
Electrical Works
Digitally signed by AMIT
S.No. DESCRIPTION UNIT QTY DSR RATE DSR AMOUNT NDSR RATE NDSR AMOUNT
Supply , installation ,testing and commissioning of 'MCB double door
Distribution Boards dust and vermin 'proof protected and AC supply
operation including incoming MCB/ELCB/RCBO/MCCB as per
1 specifications and required capacity Neutral bar and Earth Terminal
complete as required and installed in concealed in wall after necessary
chase cutting with finishing /surface on wall including all fixing materials
12Way TPN MCB DB(Vertical type) with 63A 4P RCCBas incoming and 36
nos (6-32A-10KA )SP MCB as outgoing.(ACDB)
Point wiring for light point /Fan/Exhaust Fan point/ call bell point using 2
runs of 1100 V grade 1.5 sqmm & one run of 1.5 sq.mm FRLS insulated
multistranded copper wires, in & including 25 mm dia , MS conduit surface/
2 concealed in wall / ceiling conferming to IS 732 including all accessries
such as junction boxes , conduit bends, elbows and ceiling rose , and
anodised GI switch box with modular switch ,modular plate and the box
covered with front plate
Wiring for circuit/ submain wiring alongwith earth wire with the following
3 1.7 sizes of FRLS PVC insulated copper conductor, single core cable in
surface/ recessed steel conduit as required.
3.1 1.7.1 2x1.5sqmm+1x1.5sqmmearth wire Per mtr. 150.00 327.00 49,050.00
Supply and fixing of following sizes of MS conduit along with accessories
4 1.20 in surface /recess including painting in case of surface conduit,or cutting
the wall and making good the same in case of recessed conduit as required
Supply, Installation, Testing and Commisioning of Suspended
/surface/Recessed type linear Luminaire of size 72mm (N.S.), Linear ultra
modular fixture made up of extruded aluminium housing with luminare
efficasy more than 100 LPW, CRI >80, CCT of 5700K. suitable for 220 V,
50 Hz, The luminare rated life (L70) >50000 Hours with High efficiency
driver with inbuild surge protection, over voltage protection, short circuit
protection and operating at >0.95 .making suitable arrangement for fixing
including connection with 3 x 1.5 sq.mm. The price shall include all
accessories including jointing kit for uniform continuous lines of light across
ceiling etc complete in all respect
SITC of heavy duty 100W (min) wall mounted fan having a blade length of
18 inches. It should have 3 speed control and a 90 degree oscillatiion and a
safety guard as per approved sample complete with all accessories as
SITC of 200mm dia inline exhaust fan of 500 cfm. It shall have a rotational
7 MR speed of 2500 rpm and a noise level of maximum 45 dB as per approved Nos 6.00 14,950.00 89,700.00
sample complete with all accessories as required.
Digitally signed by AMIT
RENOVATION WORKS AT IIPA, NEW DELHI - CORRIDOR (GOUND FLOOR - LEFT WING)
S.No. DESCRIPTION UNIT QTY DSR RATE DSR AMOUNT NDSR RATE
Ref. No. AMOUNT
Dismantling tile work in floors and roofs laid in cement mortar including
stacking material within 50 metres lead.
15.23.2 For thickness of tiles above 25 mm and up to 40 mm SQM 130.00 113.55 14,761.50
Dismantling aluminium / Gypsum partitions, doors, windows, fixed glazing
and false ceiling including disposal of unserviceable surplus material and
stacking of serviceable material with in 50 meters lead as directed by
Engineer-in-Charge.
Carriage of material by mechanical transport including loading unloading
1.1.1 Lime, murrum, building rubbish
Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stone
4 11.3 aggregate) finished with a floating coat of neat cement, including cement
slurry, but excluding the cost of nosing of steps etc. complete.
11.3.1 40 mm thick with 20 mm nominal size stone aggregate SQM 130.00 614.20 79,846.00
Providing and applying fibre reinforced elastomeric liquid water proofing
membrane with resilient acrylic polymers having Sun Reflectivity Index (SRI)
of 105 on top of concrete roof in three coats @10.76 litre/ 10 sqm. One coat
of self-priming of elastomeric waterproofing liquid (dilution with water in the
5 22.22A ratio of 3:1) and two coats of undiluted elastomeric waterproofing liquid (dry sqm 130.00 563.10 73,203.00
film thickness of complete application/system not less than 500 microns).
The operation shall be carried out after scrapping and properly cleaning the
surface to remove loose particles with wire brushes, complete in all respect
as per the direction of Engineer-in-Charge.
Providing & Applying polymer modified, flexible cementatious negative side
waterproofing coating with elastic waterproofing polymers on interior wall
plaster surface in three coats @14.35 kg /10 sqm. one coat of self priming of
cementatious waterproofing polymer(dilution with water in the ratio of 1:1)
and two coats of cementatious waterproofing polymer (dilution with water in
the ratio of 3:1 ) after scrapping and properly cleaning the surface to remove
pre-existing paint film & loose particles till plaster is visible, complete in all
respect as per the direction of Engineer-in-Charge.
Digitally signed by AMIT
Providing and laying Vitrified tiles in floor in different sizes (thickness to be
specified by the manufacturer) with water absorption less than 0.08% and
conforming to IS:15622, of approved brand & manufacturer, in all colours
and shade, laid on 20 mm thick cement mortar 1:4 (1 cement: 4 coarse
7 11.41A sand) jointing with grey cement slurry @3.3 kg/sqm including grouting the
joints with white cement and matching pigments etc. The tiles must be cut
with the zero chipping diamond cutter only . Laying of tiles will be done with
the notch trowel, plier, wedge, clips of required thickness, leveling system
and rubber mallet for placing the tiles gently and easily.
11.41A.2 Glazed vitrified floor tiles polished finish of size
TILE DADO :- Providing and fixing Vitrified tiles conforming to IS: 15622
(thickness to be specified by the manufacturer), of approved make, in all
Based of colours and shade of size 800 x 1200mm as approved by Engineer-in-
8 DSR Charge, in skirting, risers of steps and dados, over 12 mm thick bed of SQM 110.00 1,268.29 1,39,512.23
8.31 cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement
slurry @ 3.3kg per sqm, including pointing in white cement mixed with
pigment of matching shade complete.
Grouting the joints of flooring tiles having joints of upto 5 mm width, using
epoxy grout mix of 0.70 kg of organic coated filler of desired shade (0.10 kg
of hardener and 0.20 kg of resin per kg), including filling / grouting and
finishing complete as per direction of Engineer-in-charge.
CEMENT PLASTER :- 15 mm cement plaster on the rough side of single or
half brick wall of mix.
Wall painting with acrylic emulsion paint, having VOC content less that 50
11 13.82 grams / litre, of approved brand and manufacture, including appliying
additional coats wherever required, to achive even shade and colour.
Preparation of complete set of shop drawings including finishing, MEP
services, details, design calcualtions etc. and any other details as and when
desired by Engineer In charge /client. A qualified professsional for the
purpose shall be appointed after due appproval from Engineer In Charge.
Electrical Works
Point wiring for light point /Fan/Exhaust Fan point/ call bell point using 2
runs of 1100 V grade 1.5 sqmm & one run of 1.5 sq.mm FRLS insulated
multistranded copper wires, in & including 25 mm dia , MS conduit surface/
1 concealed in wall / ceiling conferming to IS 732 including all accessries such
as junction boxes , conduit bends, elbows and ceiling rose , and anodised
GI switch box with modular switch ,modular plate and the box covered with
Digitally signed by AMIT
Wiring for circuit/ submain wiring alongwith earth wire with the following
2 1.7 sizes of FRLS PVC insulated copper conductor, single core cable in surface/
recessed steel conduit as required.
2.1 1.7.1 2x1.5sqmm+1x1.5sqmmearth wire Per mtr. 200.00 327.00 65,400.00
Supply and fixing of following sizes of MS conduit along with accessories
3 1.20 in surface /recess including painting in case of surface conduit,or cutting
the wall and making good the same in case of recessed conduit as required
Supplying, Installation, Testing & Commissioning of recessed type LED
downlighter having the following specifications etc. complete as reqd: -
a) Total Lumens : Not less than 1600 Lumens
b) System lumens efficacy : Not less than 105 lumen P/Watt
c) Driver efficiency : Not less than 85%
d) THD : Not more than 10%
e) CRI : Not less than 80
f) LED Life : Not less than 50000 hours @ LM 70%
g) Colour temperature : 4000-5500 K
h) Operating voltage range : 140 Volt to 270 Volt
i) Installation type : Recessed suitable for armstrong/grid/POP/Gypsum
j) Material of construction for housing : Pressure diecast aluminium
k) Material of construction for cover : High quality polycarbonate opal
concave diffuser.
l) Reflector - High reflective polycarbonate conical shaped
m) Electronic Driver : Integral type (Constant current supply)
n) Internal surge protection : Not less than 2.5 kV
o) Ingress protection (IP) : Not less than IP 20.
p) Size of Luminare - Dia 158mm x Height 90mm (Plus Minus 5%)
Digitally signed by AMIT
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
NIT IIPA Canteens.pdf
Tender Document
BoQ IIPA canteen.pdf
Tender Document
SCC IIPA CANTEEN.pdf
Tender Document
GCC PMC 2022 upto Amendment 8.pdf
Tender Document
Instruction to Bidder for online Bid Submission.pdf
Tender Document
Forms.pdf
Tender Document
list of make.pdf
Tender Document
TECHNICAL Circular upto 27 amendment.pdf
Tender Document
corrigendum-2657-Corrigendum-I.pdf
pdf • 0.56 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .