Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹8.7 CrAccepted-AOC | ₹8.7 Cr | 1 | Accepted-AOC ok |
| 2 | 2₹11.6 Cr+₹2.9 Cr (33.8%)Rejected-Finance | ₹11.6 Cr+₹2.9 Cr (33.8%) | 2 | Rejected-Finance Being not L1 |
| 3 | 3₹12.0 Cr+₹3.3 Cr (38.0%)Rejected-Finance SHREE RAM COMPLEX GROUND FLOOR NH 17 KODIBAG KARWAR 581303 | KARWAR | UTTARA KANNADA | KARNATAKA | 581303 | ₹12.0 Cr+₹3.3 Cr (38.0%) | 3 | Rejected-Finance Being not L1 |
| 4 | 4₹14.4 Cr+₹5.7 Cr (66.2%)Rejected-Finance NOT SPECIFIED | ₹14.4 Cr+₹5.7 Cr (66.2%) | 4 | Rejected-Finance Being not L1 |
Tender Value
₹7.6 Cr
EMD Value
₹7.0 L
Closing Date
8 Sept 2020, 6:00 pmClosed
Sr DDG and CE
DGNP Mumbai, Naval Dockyard, Shahid Bhagat Singh Marg, Mumbai - 400023
PROVISION OF COVERED SHED AND ASSOCIATED FACILITIES FOR INSTALLATION OF MPGS-100 MACHINE AT NSRY KARWAR
2020_MES_358510_1
DGNP_MB_8494_2
Open Tender
Civil Works
Lump-sum
760 days
NSRY KARWAR
Contractors enlisted with MES/DGNP in Class S and above and category a i and b i with no adverse remarks in WLR. For further details NIT provisions to be referred.
8 documents required · 8 mandatory
₹3,000
Yes
DGNP Mumbai
₹7.0 L
Yes
26 Nov 2020
12 Jul 2020
15 Sept 2020
12 Jul 2020
8 Sept 2020
25 Aug 2020
14 Jul 2020 - 24 Jul 2020
Amount
SCHEDULE 'A' PART II-B (SITE CLEARANCE, EXCAVATION AND EARTH WORK)
Removing excavated materials to a place outside MD land with minimum distance of 1 km including loading, unloading, transportation, levelling and any other charges complete all as specified and as directed.
Removing demolished building materials etc. (other than soil considered above and items under Schedule of Credit) to place outside defence land including loading, unloading, transportation, levelling and any other charges complete all as specified and as directed. Note: Demolished concrete of 0.45 Cum shall be considered as one load.
Total amount of Sch 'A' Part II-B C/o to General Summary on Ser Page No. 136
SCHEDULE 'A' PART III-B (PILE FOUNDATION) NOTE :- The rate shall be deemed to include cost of mobilisation, positioning, setting upon and/or shifting up of piling equipment with accessories at site for piling work and removing the same from site on completion of pile work all as specified and as directed by GE.
Material and labour for boring for piles 450mm dia, through any type of soil, clay by any suitable method duly supported by drilling fluids or by temporary casing pipes including removal of excavated earth outside MD land with all its lifts and leads complete all as specified and as directed.
Material and labour for initial load testing (High Strain Dynamic) upto 55 ton capacity safe load (Ultimate load is to be applied as per pile foundation drg) on piles of 450mm dia in accordance with and all as per IS-2911 Part IV including installation, bringing on site all equipments required and removal from site after testing complete all as specified and directed.
Material and labour for lateral load testing upto 55 ton capacity safe load (Ultimate load is to be applied as per pile foundation drg) on piles of 450mm dia in accordance with all as per IS-2911 Part IV including installation, bringing on site all equipments required and removal from site after testing complete all as specified and directed.
Material and labour for routine load testing (High Strain Dynamic) upto 33 ton capacity safe load on piles of 450mm dia in accordance with all as per IS-2911 Part IV including installation, bringing on site all equipment required and removal from site after testing all as directed complete all as specified and directed.
Material and labour for integrity testing of pile 450mm dia using low strain/sonic integrity test/sonic echo test method in accordance with IS 14893 including surface preparation of pile top by removing soil, mud, dust and chipping lean concrete lumps etc. and use of computerised equipment and high skill trained personnel for conducting test and submission of result complete all as specified and directed.
Material and labour for Reinforced cement concrete M-35 (Design Mix) (using 20mm graded crushed stone aggregate) as per IS: 456 in piles of any length/size including casting and knocking down waste concrete complete all as specified and as directed. NOTE: RCC shall be measured and paid up to the cut off level and rate quoted shall be inclusive of cutting and knocking of RCC waste from the cut off level.
Total amount of Sch 'A' Part III-B C/o to General Summary on Ser Page No. 136
SCHEDULE 'A' PART IV-B (INTERNAL ELECTRIFICATION)
Material and labour for surface mounted round luminaire- 6W LED, with all accessories pre-wired including connecting up with twin core twisted flexible copper conductor cable with suitable size complete all as specified and as directed. Make :- Shakti, Model SZSDRMX006 or equivalent model of makes CG/WIPRO/HAVELLS
Supply and fixing surface mounted weather and corrosion proof polymer housing, IP 65/66, 18W LED complete with all accessories internally pre-wired including connecting up with twin core flexible copper cable with suitable size complete all as specified and as directed. Make :- Shakti, Model SZSCPMX018 or equivalent model of makes CG/WIPRO/HAVELLS
Supply and fixing bulk head light 12W LED polymer housing, complete with all accessories internally pre-wired including connecting up with twin core flexible copper cable with suitable size complete all as specified and as directed. Make :- Shakti, Model SZSBHMX012 or equivalent model of makes CG/WIPRO/HAVELLS
Supply and fixing surface industrial batten tube light 24 Watt LED, aluminium extruded channel powder coated with reflector and diffuser for glare free light complete with all accessories internally pre-wired and including connection up with twin core twisted flexible copper conductor cable 1.5 sqmm (FRLSH) ISI Marked complete all as specified and as directed. Make :- Shakti, Model SZSIBMX1-24 or equivalent model of makes CG/WIPRO/HAVELLS
Supply and fixing highbay luminaire fitting- 70W LED, complete with all accessories internally pre-wired and including connecting up with twin core twisted flexible copper conductor cable with suitabel size complete all as specified and as directed. Make :- Shakti, Model SZHHAMX070 or equivalent model of makes CG/WIPRO/HAVELLS
Supply and fixing fire exit sign (illuminated) with 8W LED lamp, with upto 3 hours battery backup complete all as specified and as directed.
Supply and fixing wall bracket LED street/security light fitting 40 watt housing made out of pressure die-cast aluminium alloy with toughned glass, IP- 65 protection, working on 240 volts, 50 Hz, consisting of reflective lens, wired with appropriate driver PF>0.98 having over voltage protection upto 400 volts, surge protection level 7-10 KV, thermal short protection THD<10%, made up of long life LED chips (SMD) in modular with Ra>70 and LED lumen efficiency >120 lumen per watt, including fixed on pole with 02 Nos MS clamps made out of 40 x 6 mm FI and bracket made out of 40 mm dia light grade GI pipe not less than 1.2 metre long bent to shape including connecting with 1.5 sqmm, 3 core, PVC insulated copper conductor cable, 1100 volts grade complete all as specified and as directed. Make :- Shakti, Model SZPSLMM040 or equivalent model of makes CG/WIPRO/HAVELLS
Note: Contractor shall submit the guarantee from manufacturer for LED light fitting including driver for minimum of 3 years for any defects developed during the period.
Supply and fixing air circulator wall mounted, 450 mm Sweep, 3 blade 230 volts AC, 50 Hz 180W (Approx) 1440 RPM complete including vertical angle adjustable from 22 to 45 Degrees including fixing MS brackets of suitable size, bolts, nuts washers complete all as specified and as directed. Make :- KHAITAN/CG/HAVELLS/USHA
Supply and fixing exhaust fan heavy duty size 300 mm Sweep single phase and 900 RPM with bracket, louvers, opening the wall and grouting with MS rag bolts etc. and connecting from ceiling rose/ connector to fan with and including provision of PVC insulated and sheathed three core copper conductor flexible cable FRLSH of size not less than 1.5 sq mm sufficient length complete all as specified and as directed. Make :- KHAITAN/CG/HAVELLS/USHA
Supply and fixing exhaust fan heavy duty size 450 mm Sweep single phase and 900 RPM with bracket, louvers, opening the wall and grouting with MS rag bolts etc. and connecting from ceiling rose/ connector to fan with and including provision of PVC insulated and sheathed three core copper conductor flexible cable FRLSH of size not less than 1.5 sq mm sufficient length complete all as specified and as directed. Make :- KHAITAN/CG/HAVELLS/USHA
Supply and fixing MCB DB TPN 8 way pre-wired vertical double door type of steel sheet for 415V on surface/recess complete with loose wire box of sheet steel, dust protected, duly powder painted, inclusive of 200 Amps tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCB's , terminal connectors for all incoming and outgoing circuits, duly pre-wired with adequate size of FRLSH PVC insulated copper conductor upto the terminal connector/ neutral link, earthing etc as required including incomer MCCB 100 Amps, 4 Pole, 50Hz, 25 KA (Ics=100%Icu) (Adjustable Thermal & Magnetic type) complete all as specified and as directed.
Supply and fixing sheet metal MCB DB TPN 6 way 415 volts, vertical double door type powder coated with 200 Amps rated copper bus bar, neutral link, earth rail & din rail, lSI marked for fixing of MCBs, Isolator, RCOBs/ RCCBs, ELCBs etc. complete all as specified and as directed. Notes :- (i) MCBs, Isolator, RCOBs/RCCBs, ELCBs measured & paid for separately under respective items. (ii) MCBs, Isolator, RCOBs/ RCCBs, ELCBs shall be of uniform make.
Supply and fixing MCB TPN 40A, "C" curve breaking capacity Icu=Ics=10KA, 415 volts, 50 Hz, ISI marked with cable connection and copper lugs complete all as specified and as directed.
Supply and fixing MCB TPN 63A, "C" curve breaking capacity Icu=Ics=10KA, 415 volts, 50 Hz, ISI marked with cable connection and copper lugs complete all as specified and as directed.
Supply and fixing MCB DP 25A, "C" curve breaking capacity Icu=Ics=10KA, 240 volts, ISI marked with cable connection and copper lugs complete all as specified and as directed.
Supply and fixing MCB SP 6 to 20A, "C" curve breaking capacity Icu=Ics=10KA, 240 volts, ISI marked with cable connection and copper lugs complete all as specified and as directed.
Supply and hanging ceiling fan 5 star rated labeled with double ball bearing, 350 RPM, 1200mm sweep 140-285 volts AC 50Hz, PF 0.99 with super energy efficient BLDC Motor and power consumption shall not be more than 28W under standard test condition along with down rod, canopy and all accessories along with smart remote controlled all as supplied by manufacturer and making necessary electrical connection with 3 core flexible copper conductor 1100 Volts grade of suitable size (not less than 1.5 sqmm) and length including and making necessary electric connection etc complete all as specified and as directed. NOTE : Contractor shall submit the guarantee from manufacturer for ceiling fan for minimum 3 years for any defects developed during the period.
Supply, fabricating and installing perforated corrosion resistant polyester flame retardant UV Stabilised resin system and various types of glass fibre cable trays including horizontal vertical bends, reducers, tees, cross members and other accessories as required and duly suspended from the ceiling with MS suspenders and inculding painting with powder coating etc. as required of perforated type cable tray of width - 150mm, Height- 50mm and 3mm thick complete all as specified and as directed. Make :- Elecon Cable Tray/Obo/Legrand
Supply, fabricating and installing perforated corrosion resistant polyester flame retardant UV Stabilised resin system and various types of glass fibre cable trays including horizontal vertical bends, reducers, tees, cross members and other accessories as required and duly suspended from the ceiling with MS suspenders and inculding painting with powder coating etc. as required of perforated type cable tray of width - 300mm, Height- 75mm and 5mm thick complete all as specified and as directed. Make :- Elecon Cable Tray/Obo/Legrand
Supply, fabricating and installing perforated corrosion resistant polyester flame retardant UV stabilised resin system and various types of glass fibre cable trays including horizontal vertical bends, reducers, tees, cross members and other accessories as required and duly suspended from the ceiling with MS suspenders and inculding painting with powder coating etc. as required of FRP perforated trough type cable tray of width- 450mm, Height- 75mm and 4mm thick complete all as specified and as directed. Make :- Elecon Cable Tray/Obo/Legrand
Supply, fabricating and installing perforated/ ladder corrosion resistant polyester flame retardant UV stabilised resin system and various types of glass fibre cable trays including horizontal vertical bends, reducers, tees, cross members and other accessories as required and duly suspended from the ceiling with MS suspenders and inculding painting with powder coating etc. as required of FRP ladder type cable tray of width - 600mm and channel size - 100 x 35 x 3 mm complete all as specified and as directed. Make :- Elecon Cable Tray/Obo/Legrand
Supply, fabricating and installing FRP splice plate straight size - 200 x 70 x 4mm with 8 set of M6 x 25mm Hardware SS304 (for 100mm high tray) for perforated glass fibre cable trays complete all as specified and as directed.
Supply, fabricating and installing FRP splice plate straight size- 200 x 50 x 4mm with 4 set of M5 x 20mm Hardware SS304 (for 75mm High tray) for perforated glass fibre cable trays complete all as specified and as directed.
Supply, fabricating and installing FRP splice plate straight size - 200 x 25 x 4mm with 4 set of M5 x 20mm Hardware SS304 (for 50mm high tray) for perforated glass fibre cable trays complete all as specified and as directed.
Material and labour for submain wiring with two Nos single core PVC insulated-unsheathed 2.5 sqmm stranded copper conductor cable, ISI marked with IS 694 and 1 No single core PVC insulated-unsheathed 2.5 Sqmm stranded copper conductor cable ISI marked with IS 694 for earth continuity, drawn in and including suitable dia (but not less than 20 mm dia) surface rigid stove steel conduit medium grade with all conduit fitting (lSI marked) complete all as specified and as directed. Note : Two runs of current carrying conductor cable, one run of earth continuity conductor cable & one run of steel conduit shall be measured as one unit length.
Material and labour for submain wiring with two Nos single core PVC insulated-unsheathed 4 sqmm stranded copper conductor cable, ISI marked with IS 694 and 1 No single core PVC insulated-unsheathed 4 Sqmm stranded copper conductor cable ISI marked with IS 694 for earth continuity, drawn in and including suitable dia (but not less than 20 mm dia) surface rigid stove steel conduit medium grade with all conduit fitting (lSI marked) complete all as specified and as directed. Note : Two runs of current carrying conductor cable, one run of earth continuity conductor cable & one run of steel conduit shall be measured as one unit length.
Material and labour for submain wiring with two Nos single core PVC insulated-unsheathed 6 sqmm stranded copper conductor cable, ISI marked with IS 694 and 1 No single core PVC insulated-unsheathed 6 Sqmm stranded copper conductor cable ISI marked with IS 694 for earth continuity, drawn in and including suitable dia (but not less than 20 mm dia) surface rigid stove steel conduit medium grade with all conduit fitting (lSI marked) complete all as specified and as directed. Note : Two runs of current carrying conductor cable, one run of earth continuity conductor cable & one run of steel conduit shall be measured as one unit length.
Material and labour for submain wiring with two Nos single core PVC insulated-unsheathed 10 sqmm stranded copper conductor cable, ISI marked with IS 694 and 1 No single core PVC insulated-unsheathed 10 Sqmm stranded copper conductor cable ISI marked with IS 694 for earth continuity, drawn in and including suitable dia (but not less than 20 mm dia) surface rigid stove steel conduit medium grade with all conduit fitting (lSI marked) complete all as specified and as directed. Note : Two runs of current carrying conductor cable, one run of earth continuity conductor cable & one run of steel conduit shall be measured as one unit length.
Material and labour for submain wiring with four Nos single core PVC insulated-unsheathed 6 sqmm stranded copper conductor cable, ISI marked with IS 694 and two Nos single core PVC insulated-unsheathed 6 Sqmm stranded copper conductor cable ISI marked with IS 694 for earth continuity, drawn in and including suitable dia (but not less than 25 mm dia) surface rigid stove steel conduit medium grade with all conduit fitting (lSI marked) complete all as specified and as directed. Note : Four runs of current carrying conductor cable, two runs of earth continuity conductor cable & one run of steel conduit shall be measured as one unit length.
Material and labour for submain wiring with four Nos single core PVC insulated-unsheathed 10 sqmm stranded copper conductor cable, ISI marked with IS 694 and two Nos single core PVC insulated-unsheathed 10 Sqmm stranded copper conductor cable ISI marked with IS 694 for earth continuity, drawn in and including suitable dia (but not less than 25 mm dia) surface rigid stove steel conduit medium grade with all conduit fitting (lSI marked) complete all as specified and as directed. Note : Four runs of current carrying conductor cable, two runs of earth continuity conductor cable & one run of steel conduit shall be measured as one unit length.
Material and labour for submain wiring with four Nos single core PVC insulated-unsheathed 16 sqmm stranded copper conductor cable, ISI marked with IS 694 and two Nos single core PVC insulated-unsheathed 16 Sqmm stranded copper conductor cable ISI marked with IS 694 for earth continuity, drawn in and including suitable dia (but not less than 25 mm dia) surface rigid stove steel conduit medium grade with all conduit fitting (lSI marked) complete all as specified and as directed. Note : Four runs of current carrying conductor cable, two runs of earth continuity conductor cable & one run of steel conduit shall be measured as one unit length.
Total amount of Sch 'A' Part IV-B C/o to General Summary on Ser Page No. 137
SCHEDULE 'A' PART V (SOLAR POWER SUPPLY)
Design, supply ,installation, commissioning and testing power plant of capacity 30KW on grid system consisting of following items:- (a) Solar Photovoltaic Modules (b) INVERTOR (c) Modular Mounting Structure (d) String Junction Box (e) DCDB (f) AC Distribution Board (g) Solar Cable (h) Electric Power Cable (j) Earthing (k) Duel Net meter Note : Solar Power plant shall be designed as per Particular Specification Clause No. 24 and its sub clauses.
Total amount of Sch 'A' Part V C/o to General Summary on Ser Page No. 137
SCHEDULE 'A' PART X-B (EXTERNAL ELECTRIC SUPPLY)
Design, Supply, Fabrication, Installation, Testing and Commissioning factory made, LTpanel board, Indoor type, totally enclosed, dust and vermin proof, suitably ventilated, floor mounted, 415 volts,3 phase and neutral, 50Hz, AC supply system, fully compartmentalized, made out of 2 mm thick CRCA sheet steel, protection of enclosure IP- 54 as per IS : 2147 with pre-treatment and powder coated of approved color including suitable frame work/ support made out of suitable size of angle iron/flat iron, front opening type with provision for cable entry, with proper ferrule and cable glands, internal wiring with PVC insulated multi-stranded Copper conductor FRLSH cable of adequate size (minimum 1.5sq mm), required civil works/ anchoring bolts for fixing, PCC foundation, having separate compartment of suitable size to accommodate 100KVAR APFC etc. with and including following:-
(d) AC three phase LT/ CT multifunctional energy meter of accuracy class-0.5, 3 x 240 volts 50 Hz, with optical and RS 232 port, LCD display, measures and display, trivector energy and load survey, TOD temper detection and lagging power on/off events, instantaneous parameter of rating - 5 Amps, with display in absence of power complete - 01 No. (e) Phase Indication lamps (RYB), LED type - 01 No. (set of three) (f) MCB SP 2 Amps, 'C' series for control protection RYB phases (set of 3) - 01 set. (iii) OUTGOING (a) MCCB 200 Amps, 415 volts, 4 pole, 50 Hz, 35KA (Ics=100% Icu) Adjustable Thermal & Magnetic type - 02 Nos (b) MCCB 160 Amps, 415 volts 4 pole,50 Hz, 25KA (Ics=100%Icu) Adjustable Thermal & Magnetic type - 02 Nos (c) MCCB 125 Amps,415 volts 4 pole,50 HZ, 25KA (Ics = 100%Icu) Adjustable Thermal & Magnetic type - 03 Nos (d) MCCB 100 Amps, 415 volts 4 pole, 50 Hz, 16KA, (Ics = 100%Icu) Adjustable Thermal & Magnetic type - 01 No
(e) MCCB 40 Amps, 415 volts 4 pole,50 Hz, 16 KA, (Ics = 100%Icu) Adjustable Thermal & Magnetic type - 01 No APFC Panel 100 KVAR shall be having following specifications integrated with main panel :- (a) Power supply: 3 phase 4 wire line (b) Power rating: 100 KVAR (c) Rated system voltage: 415 volts, 50Hz (d) Duty: continuous (e) Main incoming MCCB 200 Amp, 415 V, 35 KA, 4 pole - 01No (f) Power factor corrector relay 12 stage- 01 No (g) Capacitor duty contactor for 20 KVAR- 03 Nos (h) Capacitor duty contactor for 10 KVAR - 02 Nos (j) Power contactor 18 Amp for 5 KVAR- 02 Nos (k) Power contactor 18 Amp for 2 KVAR- 05 Nos (l) MCB 40 A, 10 KA TP for 20 KVAR- 03 Nos
Design, Supply, Fabrication,Installation, Testing and Commissioning factory made, LTpanel board, Indoor type, totally enclosed, dust and vermin proof, suitably ventilated, floor mounted, 415 volts,3 phase and neutral, 50 Hz, ACsupply system, fully compartmentalized, made out of 2 mm thick CRCA sheet steel, protection of enclosure IP- 54 as per IS : 2147 with pre-treatment and powder coated of approved color including suitable frame work/ support made out of suitable size of angle iron/flat iron, front opening type with provision for cable entry, with proper ferrule and cable glands, internal wiring with PVC insulated multi stranded Copper conductor FRLSH cable of adequate size (minimum 1.5 sq mm), required civil works/ anchoring bolts for fixing, PCC foundation, having separate compartment of suitable size to accommodate 100 KVAR APFC etc. with and including following:-
(d) AC three phase LT/ CTmultifunctional energy meter of accuracy class- 0.5, 3 x 240 volts 50 Hz, with optical and RS 232 port, LCD display, measures and display, trivector energy and load survey, TOD temper and lagging power on/off events, instantaneous parameter of rating - 5 Amps, with display in absence of power complete - 01 No. (e) Phase Indication lamps (RYB), LED type (set of three) - 01 Set (f) MCB SP 2 Amps, 'C' series for control protection RYB phases (set of 3) - 01 set. (iii) OUTGOING (a) MCCB 200 Amps, 415 volts, 4 pole, 50 Hz, 25KA (Ics=100% Icu) Adjustable Thermal & Magnetic type - 02 Nos (b) MCCB 160 Amps, 415 volts 4 pole,50 Hz, 25KA (Ics=100%Icu) Adjustable Thermal & Magnetic type - 02 Nos (c) MCCB 125 Amps,415 volts 4 pole,50 HZ, 16KA (Ics = 100%Icu) Adjustable Thermal & Magnetic type - 02 Nos
(d) MCCB 63 Amps, 415 volts 4 pole, 50 Hz, 16KA, (Ics = 100%Icu) Adjustable Thermal & Magnetic type - 01 No APFC Panel 100 KVAR shall be having following specification integrated with main panel : (a) Power supply: 3 phase 4 wire line (b) Power rating: 100 KVAR (c) Rated system voltage: 415 volts, 50Hz (d) Duty: continuous (e) Main incoming MCCB 200 Amp, 36 KA, 4 pole - 01No (f) Power factor corrector relay 12 stage - 01 No (g) Capacitor duty contactor for 20 KVAR - 03 Nos (h) Capacitor duty contactor for 10 KVAR - 02 Nos (j) Power contactor 18 Amp for 5 KVAR - 02 Nos (k) Power contactor 18 Amp for 2 KVAR - 05 Nos (l) MCB 40 A, 10 KA TP for 20 KVAR - 03 Nos
Notes :- (for Srl Item Nos 10.01 & 10.02) 1. Panel manufacrurers shall have in house powder coating plant with minimum 8 tanks pretreatment of MS sheet facilities, dust free spray paint booth. (8 tanks pretreatment process includes: degreasing / water rinsing / de-rusting / water rinsing / activation / phosphating / water rinsing / passivation). 2. Thickness of powder coating shall not be less than 80 microns and test certificate for powder coating shall be furnished along with LT panel.
3. Pre dispatch inspection shall be carried out by the authorized rep of Accepting Officer. In case of any deviation from approved drawing, the same will be rejected and fresh LT panel shall be got fabricated by the contractor from manufacturer. Testing shall be done at manufacturer's premises and all routine test like IR and continuity tests shall be performed/ recorded in presence of authorized rep of Accepting Officer. 4. The panel manufacturer shall have following certification : (i) CPRI certification Degree of protection IP-54 should be in accordance to IEC:60439 & IEC:61439 as applicable. (ii) CPRI certification short circuit with stand strength should be 50KA RMS for 1 sec with initial peak of 105 KA. (iii) CPRI certification rated current for short circuit not less than 5000 A
5. MCCB (which are microprocessor based) / ACBs provided shall be capable for on line setting of the current. 6. ACBs provided shall be capable for on line setting to the time delay. 7. All the electrical switch gear like MCCBs, MCBs and ACBs shall be of same make. 8. All incomer ACBs and MCCBs (which are microprocessor based) shall be compatible with SCADA through communication port for monitoring purpose only. 9. Drawing of panel board shall be got approved from GE before fabrication. 10. Panel board shall be fully compartmentalized in accordance with form 4 b of IEC 61439-1-2. 11. Any item technically required for proper functioning of APFC panel but not mentioned in the item shall be deemed to be included in item rate. 12. The copper bus bar should be tinned and current density should not be more than 1.6 Amps per Sq mm.
Design, Supply, Fabrication, Installation, Testing and Commissioning factory made, LT panel board, Indoor type, totally enclosed, dust and vermin proof, suitably ventilated, floor mounted, 415 volts, 3 phase and neutral, 50 Hz, AC supply system, fully compartmentalized, made out of 2 mm thick CRCA sheet steel, protection of enclosure IP- 54 as per IS : 2147 with pre-treatment and powder coated of approved color including suitable frame work/ support made out of suitable size of angle iron/flat iron, front opening type with provision for cable entry, with proper ferrule and cable glands, internal wiring with PVC insulated multi stranded copper conductor FRLSH cable of adequate size (minimum 1.5 sq mm), required civil works/ anchoring bolts for fixing, PCC foundation etc. with and including following:-
(e) Phase Indication lamps (RYB), LED type (set of three) - 01 Set (f) MCB SP 2 Amps, 'C' series for control protection RYB phases (set of 3) - 01 set. (iii) OUTGOING (a) MCB TPN,63 A, 415 volts 16KA, 50 Hz, 'C' curve with lSI marked complete with all accessories with Three phase industrial socket with plug - 02 Nos (b) MCB DP 40A, 16KA, 50 Hz, 'C' curve with lSI marked complete with all accessories with single phase industrial socket with plug - 01 No (c) MCB TPN 32A, , 415 volts 16KA, 50 Hz, 'C' curve with lSI marked complete with all accessories with Three phase industrial socket with plug - 01 No
Design, Supply, Fabrication, Installation, Testing and Commissioning factory made, LT panel board, Indoor type, totally enclosed, dust and vermin proof, suitably ventilated, floor mounted, 415 volts, 3 phase and neutral, 50 Hz, AC supply system, fully compartmentalized, made out of 2 mm thick CRCA sheet steel, protection of enclosure IP- 54 as per IS : 2147 with pre-treatment and powder coated of approved color including suitable frame work/ support made out of suitable size of angle iron/flat iron, front opening type with provision for cable entry, with proper ferrule and cable glands, internal wiring with PVC insulated multi stranded copper conductor FRLSH cable of adequate size (minimum 1.5 sq mm), required civil works/ anchoring bolts for fixing, PCC foundation, etc. with and including following:-
(e) Phase Indication lamps (RYB), LED type (set of three) - 01 Set (f) MCB SP 2 Amps, 'C' series for control protection RYB phases (set of 3) - 01 set. (iii) OUTGOING (a) MCCB 100 Amps, 415 volts 4 pole, 50 Hz, 16 KA (Ics = 100%Icu) Adjustable Thermal & Magnetic type, three phase industrial socket with plug - 01 No (b) MCB TPN,63 A, 16KA, 50 Hz, 'C' curve with lSI marked complete with all accessories with Three phase industrial socket with plug -01 No (c) MCB DP 40A, 16KA, 50 Hz, 'C' curve with lSI marked complete with all accessories with single phase industrial socket with plug - 01 No (d) MCB TPN 32A, , 415 volts 16KA, 50 Hz, 'C' curve with lSI marked complete with all accessories with Three phase industrial socket with plug - 01 No
Design, Supply, Fabrication, Installation, Testing and Commissioning factory made, LT panel board, Indoor type, totally enclosed, dust and vermin proof, suitably ventilated, floor mounted, 415 volts, 3 phase and neutral, 50 Hz, AC supply system, fully compartmentalized, made out of 2 mm thick CRCA sheet steel, protection of enclosure IP- 54 as per IS : 2147 with pre-treatment and powder coated of approved color including suitable frame work/ support made out of suitable size of angle iron/flat iron, front opening type with provision for cable entry, with proper ferrule and cable glands, internal wiring with PVC insulated multi stranded Copper conductor FRLSH cable of adequate size (minimum 1.5 sq mm), required civil works/ anchoring bolts for fixing, PCC foundation, etc. with and including following:-
(e) Phase Indication lamps (RYB), LED type (set of three) - 01 Set (f) MCB SP 2 Amps, 'C' series for control protection RYB phases (set of 3) - 01 set. (iii) OUTGOING (a) MCB TPN,63 A, 16KA, 50 Hz, 'C' curve with lSI marked complete with all accessories with Three phase industrial socket with plug - 02 Nos (b) MCB TPN 32A, , 415 volts 16KA, 50 Hz, 'C' curve with lSI marked complete with all accessories with Three phase industrial socket with plug - 01 No
Design, Supply, Fabrication, Installation, Testing and Commissioning factory made, LT panel board, Indoor type, totally enclosed, dust and vermin proof, suitably ventilated, floor mounted, 415 volts, 3 phase and neutral, 50 Hz, AC supply system, fully compartmentalized, made out of 2 mm thick CRCA sheet steel, protection of enclosure IP- 54 as per IS : 2147 with pre-treatment and powder coated of approved color including suitable frame work/ support made out of suitable size of angle iron/flat iron, front opening type with provision for cable entry, with proper ferrule and cable glands, internal wiring with PVC insulated multi stranded Copper conductor FRLSH cable of adequate size (minimum 1.5 sq mm), required civil works/ anchoring bolts for fixing, PCC foundation, etc. with and including following:-
(e) Phase Indication lamps (RYB), LED type (set of three) - 01 Set (f) MCB SP 2 Amps, 'C' series for control protection RYB phases (set of 3) - 01 set. (iii) OUTGOING (a) MCB TPN,100 A, 415 volts 16 KA,50 Hz, 'C' curve with lSI marked complete with all accessories with Three phase industrial socket with plug - 01 No (b) MCB TPN,63 A, 415 Volts, 16KA, 50 Hz, 'C' curve with lSI marked complete with all accessories with Three phase industrial socket with plug - 01 No (c) MCB TPN 32A, , 415 volts 16KA, 50 Hz, 'C' curve with lSI marked complete with all accessories with Three phase industrial socket with plug - 01 No
Design, Supply, Fabrication, Installation, Testing and Commissioning factory made, LT panel board, Indoor type, totally enclosed, dust and vermin proof, suitably ventilated, floor mounted, 415 volts, 3 phase and neutral, 50 Hz, AC supply system, fully compartmentalized, made out of 2 mm thick CRCA sheet steel, protection of enclosure IP- 54 as per IS : 2147 with pre-treatment and powder coated of approved color including suitable frame work/ support made out of suitable size of angle iron/flat iron, front opening type with provision for cable entry, with proper ferrule and cable glands, internal wiring with PVC insulated multi stranded Copper conductor FRLSH cable of adequate size (minimum 1.5 sq mm), required civil works/ anchoring bolts for fixing, PCC foundation, etc. with and including following :-
(e) Phase Indication lamps (RYB), LED type (set of three) - 01 Ser (f) MCB SP 2 Amps, 'C' series for control protection RYB phases (set of 3) - 01 set. (iii) OUTGOING (a) MCB TPN,63 A, 415 Volts, 16KA, 50 Hz, 'C' curve with lSI marked complete with all accessories - 12 Nos
Notes :- (for Srl Item Nos 10.03 to 10.07) 1. Panel manufacrurers shall have in house powder coating plant with minimum 8 tanks pretreatment of MS sheet facilities, dust free spray paint booth. (8 tanks pretreatment process includes: degreasing / water rinsing / de-rusting / water rinsing / activation / phosphating / water rinsing / passivation). 2. Thickness of powder coating shall not be less than 80 microns and test certificate for powder coating shall be furnished along with LT panel. 3. Pre dispatch inspection shall be carried out by the authorized rep of Accepting Officer. In case of any deviation from approved drawing, the same will be rejected and fresh LT panel shall be got fabricated by the contractor from manufacturer. Testing shall be done at manufacturer's premises and all routine test like IR and continuity tests shall be performed/ recorded in presence of authorized rep of Accepting Officer.
4. The panel manufacturer shall have following certification : (i) CPRI certification Degree of protection IP-54 should be in accordance to IEC:60439 & IEC:61439 as applicable. (ii) CPRI certification short circuit with stand strength shall be 50KA RMS for 1 sec with initial peak of 105 KA. (iii) CPRI certification rated current for short circuit not less than 5000A 5. MCCB (which are microprocessor based) / ACBs provided shall be capable for on line setting of the current. 6. ACBs/ MCCB provided shall be capable for on line setting to the time delay. 7. All the electrical switch gear like MCCBs, MCBs and ACBs shall be of same make. 8. All incomer ACBs and MCCBs (which are microprocessor based) shall be compatible with SCADA through communication port for monitoring purpose only.
9. Drawing of panel board shall be got approved from GE before fabrication. 10. Panel board shall be fully compartmentalized in accordance with form 4 b of IEC 61439-1-2. 11. The copper bus bar should be tinned and current density should not be more than 1.6 Amps per Sq mm.
Supply and fixing factory made, MCCB box, indoor type, totally enclosed, dust and vermin proof, suitably ventilated,floor mounted, 415 volts,3 phase and neutral, 50 Hz, AC supply system, made out of 2 mm thick CRCA sheet steel, protection of enclosure IP- 54 as per IS : 2147 with pre-treatment and powder coated of approved color including suitable frame work/ support made out of suitable size of angle iron/ flat iron, front opening type with provision for cable entry, with proper ferrule and cable glands, internal wiring with PVC insulated multi stranded Copper conductor FRLSH cable of adequate size (minimum 1.5 sq mm), required civil works/ anchoring bolts for fixing, PCC foundation etc. with and including following:-
(i) MCCB 160 Amps, 415 volts,4 pole, 50 Hz, 25 KA , adjustable overload, Adjustable short circuit, instantaneous protection, Ics=100% Icu(1sec) - 01 No (ii) RYB incomer supply indicator lamp LED type -01 set with MCB for control.
Supply and fixing factory made, MCCB box, indoor type, totally enclosed, dust and vermin proof, suitably ventilated,floor mounted, 415 volts,3 phase and neutral, 50 Hz, AC supply system, made out of 2 mm thick CRCA sheet steel, protection of enclosure IP- 54 as per IS : 2147 with pre-treatment and powder coated of approved color including suitable frame work/ support made out of suitable size of angle iron/ flat iron, front opening type with provision for cable entry, with proper ferrule and cable glands, internal wiring with PVC insulated multi stranded Copper conductor FRLSH cable of adequate size (minimum 1.5 sq mm), required civil works/ anchoring bolts for fixing, PCC foundation etc. with and including following:-
(i) MCCB 200 Amps, 415 volts,4 pole, 50 Hz, 25 KA , adjustable overload, Adjustable short circuit, instantaneous protection, Ics=100% Icu(1sec) - 01 No (ii) RYB incomer supply indicator lamp LED type -01 set with MCB for control.
Supply and fixing factory made, MCCB box, indoor type, totally enclosed, dust and vermin proof, suitably ventilated,floor mounted, 415 volts,3 phase and neutral, 50 Hz, AC supply system, made out of 2 mm thick CRCA sheet steel, protection of enclosure IP- 54 as per IS : 2147 with pre-treatment and powder coated of approved color including suitable frame work/ support made out of suitable size of angle iron/ flat iron, front opening type with provision for cable entry, with proper ferrule and cable glands, internal wiring with PVC insulated multi stranded Copper conductor FRLSH cable of adequate size (minimum 1.5 sq mm), required civil works/ anchoring bolts for fixing, PCC foundation etc. with and including following:-
(i) MCCB 125Amps, 415 volts 4pole, 50 Hz, 25 KA, adjustable overload, Adjustable short circuit, instantaneous protection, Ics =100% Icu (1sec) - 01 No (ii) RYB incomer supply indicator lamp LED type -01 set with MCB for control.
Supply, Laying, Testing and Commisioning XLPE Insulated Screened PVC bedded galvanized steel strip or wire armoured, electric power cable (heavy duty) 1100 Volts grade with stranded aluminum conductor of size 10 Sqmm, 4 Core, ISI marked with IS-7098(Part-II) laid in cable trenches/ Duct/ Wall/ surfaces/ Pipe including termination with brass compression glands and copper lugs as required at site complete all as specified and as directed.
Supply, Laying, Testing and Commisioning XLPE Insulated Screened PVC bedded galvanized steel strip or wire armoured, electric power cable (heavy duty) 1100 Volts grade with stranded aluminum conductor of size 16 Sqmm, 4 Core, ISI marked with IS-7098(Part-II) laid in cable trenches/ Duct/ Wall/ surfaces/ Pipe including termination with brass compression glands and copper lugs as required at site complete all as specified and as directed.
Supply, Laying, Testing and Commisioning XLPE Insulated Screened PVC bedded galvanized steel strip or wire armoured, electric power cable (heavy duty) 1100 Volts grade with stranded aluminum conductor of size 25 Sqmm, 4 Core, ISI marked with IS-7098(Part-II) laid in cable trenches/ Duct/ Wall/ surfaces/ Pipe including termination with brass compression glands and copper lugs as required at site complete all as specified and as directed.
Supply, Laying, Testing and Commisioning XLPE Insulated Screened PVC bedded galvanized steel strip or wire armoured, electric power cable (heavy duty) 1100 Volts grade with stranded aluminum conductor of size 35 Sqmm, 3.5 Core, ISI marked with IS-7098(Part-II) laid in cable trenches/ Duct/ Wall/ surfaces/ Pipe including termination with brass compression glands and copper lugs as required at site complete all as specified and as directed.
Supply, Laying, Testing and Commisioning XLPE Insulated Screened PVC bedded galvanized steel strip or wire armoured, electric power cable (heavy duty) 1100 Volts grade with stranded aluminum conductor of size 95 Sqmm, 3.5 Core, ISI marked with IS-7098(Part-II) laid in cable trenches/ Duct/ Wall/ surfaces/ Pipe including termination with brass compression glands and copper lugs as required at site complete all as specified and as directed.
Supply, Laying, Testing and Commisioning XLPE Insulated Screened PVC bedded galvanized steel strip or wire armoured, electric power cable (heavy duty) 1100 Volts grade with stranded aluminum conductor of size 120 Sqmm, 3.5 Core, ISI marked with IS-7098(Part-II) laid in cable trenches/ Duct/ Wall/ surfaces/ Pipe including termination with brass compression glands and copper lugs as required at site complete all as specified and as directed.
Supply, Laying, Testing and Commisioning XLPE Insulated Screened PVC bedded galvanized steel strip or wire armoured, electric power cable (heavy duty) 1100 Volts grade with stranded aluminum conductor of size 150 Sqmm, 3.5 Core, ISI marked with IS-7098(Part-II) laid in cable trenches/ Duct/ Wall/ surfaces/ Pipe including termination with brass compression glands and copper lugs as required at site complete all as specified and as directed.
Supply, Laying, Testing and Commisioning XLPE Insulated Screened PVC bedded galvanized steel strip or wire armoured, electric power cable (heavy duty) 1100 Volts grade with stranded aluminum conductor of size 185 Sqmm, 3.5 Core, ISI marked with IS-7098(Part-II) laid in cable trenches/ Duct/ Wall/ surfaces/ Pipe including termination with brass compression glands and copper lugs as required at site complete all as specified and as directed.
Supply, Laying, Testing and Commisioning XLPE Insulated Screened PVC bedded galvanized steel strip or wire armoured, electric power cable (heavy duty) 1100 Volts grade with stranded aluminum conductor of size 240 Sqmm, 3.5 Core, ISI marked with IS-7098(Part-II) laid in cable trenches/ Duct/ Wall/ surfaces/ Pipe including termination with brass compression glands and copper lugs as required at site complete all as specified and as directed.
Supply, Laying, Testing and Commisioning XLPE Insulated Screened PVC bedded galvanized steel strip or wire armoured, electric power cable (heavy duty) 1100 Volts grade with stranded aluminum conductor of size 300 Sqmm, 3.5 Core, ISI marked with IS-7098(Part-II) laid in cable trenches/ Duct/ Wall/ surfaces/ Pipe including termination with brass compression glands and copper lugs as required at site complete all as specified and as directed.
NOTES FOR 10.11 TO 10.20:- (i) All testing shall be performed as per relevant IS. (ii)Testing for IR and continuity shall be recorded before and after laying of cable. (iii)Suitable glands and copper lugs for end termination of cables shall be provided by the contractor without any extra cost to the dept. (iv) No straight through joint shall be permitted. (v) Excavation, Earth work, sand, bricks and GI pipe reqd shall be measured and paid separately. (vi) Pre-despatch inspection and testing shall be carried out by the Officer detailed by the Accepting Officer. All testing shall be performed as per relevant IS.
Total amount of Sch 'A' Part X-B C/o to General Summary on Ser Page No. 138(R)
SCHEDULE 'A' PART XI-B (LIGHTNING PROTECTION)
Supply, Installation, Testing and Commissioning advance encapsulated compound based CPRI tested maintenance free, pipe-in-pipe technology upgraded (Zinc & Alloy Coated), ZINC COATED (80-100) microns with pure Zinc (99.9%) & ALLOY COATING (200-250) microns earthing system confirming IS 3034, outer and inner pipe 41.9mm dia and 26.4mm dia respectively, 2mtrs length, zinc coated with additional special Alloy coating 300mm on the topside for additional protection of the Terminal, annular space between the pipes filled up with COMPACT FILL (CF) (Crystalline Conductive compound) (COMPACT FILL (CF) mixture which is machine pressed in the pipes shall not disintegrate or collapse when outer pipes corrodes), inner pipe extended with terminals for connectivity, including digging the pits and refilling the same by Electrodite/ Conductolite backfill compound (Ground Enhancer),
(BFC shall be eco-friendly and it shall not contain environmentally hazardous material /metal having ROHS Certification from NABL accredited lab), earth pit provided with a FRP earth pit cover for protection and safe guard of terminals, complete work executed all as per manufacturer's instructions complete all as specified and as directed. NOTES :- (i) In areas where soil condition is bad, good earth shall be arranged to fill the excavated pits by mixing the same with BFC 2 bags (as per soil condition) extra per pit/unit. The material shall have good electrical conductivity and anti corrosion property in wide range of soil conditions. (ii) The quantity of BFC "Electrode" shall be increased according to soil condition and to achieve the earth value less than 1 Ohm
Total amount of Sch 'A' Part XI-B C/o to General Summary on Ser Page No. 138
SCHEDULE 'A' PART-XII (EOT CRANE)
Design, fabricate, supply, installation, testing and commissioning double girder EOT (Electrical operated over head Travelling) crane of 20 Tonne safe working load, lifting height 8 mtrs., span of 18.85 mtrs. and long travel 32 mtrs. including push button, pendents for operation from ground level , with 360 degree rotating magnetic grabber,VVVF drives, copper DSL, power cable from switch gear to DSL and control panel, suitable size rails confirming to the following complete all as specified and as directed.
NOTES :- (i) The tenderer shall submit complete technical specification including installation drawing for the make offered by him and obtain the approval of Accepting Officer. (ii) The technical specification shall be confirming to the particular specifications, any change shall be accepted subject to the superior and latest engineering practice and standardized with out any upper price adjustment. (iii) Exact measurements shall be confirmed by contractor from drawings. (iv) Crane shall be designed as per data sheet on Particular Specification Clause No 31.
Total amount of Sch 'A' Part XII C/o to General Summary on Ser Page No. 138
GENERAL SUMMARY
Lump sum price worked out by the contractor for “BUILDING AND STRUCTURE” as listed in Schedule ‘A’ Part I
Lump sum price worked out by the contractor for “SITE CLEARANCE, EXCAVATION AND EARTH WORK” as listed in Schedule ‘A’ Part II-A
Total Amount of Schedule ‘A’ Part II-B for “SITE CLEARANCE, EXCAVATION AND EARTH WORK” brought forwarded from Serial Page No 29
Lump sum price worked out by the contractor for “PILE FOUNDATION” as listed in Schedule ‘A’ Part III-A
Total Amount of Schedule ‘A’ Part III-B for “PILE FOUNDATION” brought forwarded from Serial Page No 34
Lump sum price worked out by the contractor for “INTERNAL ELECTRIFICATION” as listed in Schedule ‘A’ Part IV-A
Total Amount of Schedule ‘A’ Part IV-B for “INTERNAL ELECTRIFICATION” brought forwarded from Serial Page No 61
Total Amount of Schedule ‘A’ Part V for “SOLAR POWER SUPPLY” brought forwarded from Serial Page No 62
Lump sum price worked out by the contractor for “EXTERNAL RCC CABLE DUCT” as listed in Schedule ‘A’ Part VI
Lump sum price worked out by the contractor for “AREA DRAINAGE” as listed in Schedule ‘A’ Part VII
Lump sum price worked out by the contractor for “ROAD AND HARDSTANDING” as listed in Schedule ‘A’ Part VIII
Lump sum price worked out by the contractor for “COMPOUND WALL” as listed in Schedule ‘A’ Part IX
Lump sum price worked out by the contractor for “EXTERNAL ELECTRIC SUPPLY” as listed in Schedule ‘A’ Part X-A
Total Amount of Schedule ‘A’ Part X-B for “EXTERNAL ELECTRIC SUPPLY” brought forwarded from Serial Page No 125
Lump sum price worked out by the contractor for “LIGHTNING PROTECTION” as listed in Schedule ‘A’ Part XI-A
Total Amount of Schedule ‘A’ Part XI-B for “LIGHTNING PROTECTION” brought forwarded from Serial Page No 128
Total Amount of Schedule ‘A’ Part XII for “EOT CRANE” brought forwarded from Serial Page No 130
Lump sum price worked out by the contractor for “DEMOLITION/ DISMANTLING” as listed in Schedule ‘A’ Part XIII
KVL CONSTRUCTION
Ramshree Global Constructions Pvt. Ltd
United Sales Corporation
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .