| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹44.8 LAccepted-AOC | L1 | Accepted-AOC L1 | |
| 2 | L2₹49.5 L+₹3.8 L (8.32%)Rejected-Finance | L2 | Rejected-Finance Rejected being L2 | |
| 3 | L3₹49.8 L+₹4.1 L (9.03%)Rejected-Finance BUILDING NO FLAT NO 19 6TH CROSS ROAD SANJEEVINI NAGAR MUDALAPALYA BANGALORE 560072 | BANGALORE | BANGALORE | KARNATAKA | 560072 | L3 | Rejected-Finance Rejected being L3 | |
| 4 | L4₹51.0 L+₹5.2 L (11.5%)Rejected-Finance | L4 | Rejected-Finance Rejected being L4 | |
| 5 | L5₹52.1 L+₹6.4 L (14.0%)Rejected-Finance 606 80 FEET ROAD 7TH BLOCK 2ND PHASE BANASHANKARI 3RD STAGE BANGALORE 560 085 | BENGALURU URBAN | KARNATAKA | 560085 | L5 | Rejected-Finance Rejected being L5 |
Tender Value
₹48 L
EMD Value
₹96,000
Closing Date
2 May 2023, 6:00 pmClosed
GE I RD East Bangalore
GE I RD East Bangalore 93
REPAIRS REPLACEMENT AND MAINTENANCE OF 66 KV SF6 BREAKERS HT 11 KV BREAKERS VCBS RMUS SWITCHYARD AT MRS PHASEIII PHASEII AND OTHER CONNECTED AREA UNDER GEI RD EAST BANGALORE
2023_MES_588786_1
8391
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
GE I RD East Bangalore
D b (ii)
8 documents required · 8 mandatory
₹500
Yes
GE I R AND D East Bangalore
₹96,000
Yes
10 Aug 2023
10 Apr 2023
4 May 2023
11 Apr 2023
2 May 2023
26 Apr 2023
11 Apr 2023 - 20 Apr 2023
Amount
Supply, laying, jointing and testing cable XLPE insulated screened PVC bedded galvanized steel strip or wire armoured, electric power cables (Heavy duty) 11000 volts grade with stranded aluminum conductor of cross sectional area 3 core 185 sq mm including taking out/down old existing unserviceable cable complete all as specified and directed.
Excavation in trenches n. exc 1.5 mtr wide and n. exc 1.5 mtr in depth in soft/loose soil for laying cable/ taking out under ground cable, GI pipes and bricks laid under cable and getting out in soft/loose soil complete all as directed.
Returning, filling in trenches including spreading, leveling, watering and well ramming in layers n. exc. 25 cm thick in soft/loose soil after cables/pipes are laid and tested complete all as directed.
Removing the excavated soil to a distance n. exc. 50 mtr and depositing where directed at a level not exc. 1.5 mtr above the starting point complete all as directed.
Material and labour for sand cushioning to under ground cables 8 cm thick before laying the cable and 15 cm, thick after laying, stretching and testing the cable complete all as directed. Note: Punned thickness shall be measurement and paid.
M & L for un- reinforced pre cast concrete covers class HV type 300mmx 180mm x 40mm size factory made for cable protection complete all as specified and directed.
Supply & fix of CTs 66 KV class for following ratio out door type oil immersed as per IS 2705 with insulators electrical connection as per manufacturers instruction complete CT shall be rated voltage of 72.5 KV Core-1 5P10 for Protection, Core-2 for metering, Core-3 5P10 for Protection & Core-4: PS for REF/Differential, Ratio 100-50/1-1-1-1 Amp for 5 MVA Transformer all as specified and directed. Make:LAMCO/ABB/SCHNEIDER/PRAGATHI
Supply and fix in replacement of old unserviceable PT with new potential transformer OIL Cooled with protective enclosure of ratio 66 KV/ 110 V /RT3/110V/RT3 Class 1.0/3P, Burden 100 VA/50 VA Voltage Factor 1.2 continuous / 1.5 for 30 seconds. ILV 12/28/75 KVP. Ins class B Ref Std IS : 3156/1992 One end earthed type with one No HRC fuse on HV side. Note :Primary Neutral to be solidly earthed including removing of old unserviceable PTs. Make: LAMCO/ABB/SCHNEIDER/PRAGATHI
Supply & fix in replacement of old unserviceable Lighting arrestor expulsion type complete with all fittings, transmission class discharge capaciy of 69 KV all as specified and directed. Make: LAMCO/ABB/SCHNEIDER
Supply and fix in replacement of old unserviceable PT with new potential transformer OIL Cooled with protective enclosure of ratio 11 KV/ 110 V /RT3/110V/RT3 Class 1.0/3P, Burden 100 VA/50 VA Voltage Factor 1.2 continuous / 1.5 for 30 seconds. ILV 12/28/75 KVP. Ins class B Ref Std IS : 3156/1992 One end earthed type with one No HRC fuse on HV side. Note :Primary Neutral to be solidly earthed including removing of old unserviceable PTs. Make: LAMCO/ABB/SCHNEIDER/PRAGATHI
Supply & fix in replacement of old unserviceable CT with new CT 11 KV, CT ratio 300-150 A / 1 -1 - 1 A control relay panel & for protection complete all as specified and as directed. Make: KALPA/ INSTRANS
Supply & fix in replacement of old unserviceable CT with new CT 11 KV, consisting of CT ratio100-50 A / 5-5 A for Outgoing Feeder control relay panel for protection complete all as specified and as directed. Make: KALPA/ INSTRANS/PARAS
Material and labour for Calibration of Relays through secondary injection method and testing complete relays like IDMT relays instantaneous earth fault relays on HT OCB panel/VCB panel control SF6 breaker panel and control relay panel etc submitting reports all as directed by Engs-in -charge. Note: (i) Quarterly checking and calibration of all relays fixed in VCB, OCB, SF6 breaker for smooth functioning included in the scope of work. (ii) During quarterly checking all tripping/setting to be ensured for proper functioning of relay/breaker
Supply & Fix in replacement of Master Tripping Relay rating of 24 / 30 / 110 V dc for the existing HT VCB/OCB/RMU 11 KV Panels complete all as specified and as directed, Make: EASUN REYROLLE / C&S
Supply & Fix closing coil/Tripping coil for 11 KV 400 Amp VCB 30/110 V DC including taking out old unserviceable coil complete all as specified and as directed.
Material and labour for filteration/dehydration of transformer oil through filtration plant to improve the dielectric strength/insulation value of transformenr oil upto 50 KV at 2.5 mm gap for various capacity of 11 KV/ 433 volts step down transformer and HT OCB installed in various location complete all as specified and directed. Note: (a) The contractor will take shut down orders in working before commencement of the work from Engr in charge. (b) The contractor shall ensure no wastage of exixting transformer oil. (c) The contractor solely responsible for any dammages to the transformer/HT OCB during the prosses of oil filtration. He is responsible for making good any damage to the transformer/HT OCB at his own cost without any extra cost to the department. (d) The contractor shall ensure that the conservator tank are full to its level before starting the dehydration.
Supply and filling of New transformer oil confirming to IS 335-1963 as amended and die electric strength not less than 60 KV for topping up/replacement of unserviceable transformer oil complete all as specified and as directed. Make : Electrol/Castrol
Supply and fix HT spout bushing for VCB HT 11 KV, set of three current transformer/busbar side including taking out old unserviceable bushing complete all as specified and directed.
Supply, Fixing, Testing & Commissioning of Vaccum Interupter Bottle for the existing HT 11 KV VCB including taking out old unserviceable Vaccum Interupter Bottle complete all as specified and as directed
Supply and fix Push Buttons (Black) for the existing HT VCB/OCB/RMU 11 KV Panels for including taking out old unserviceable Push Buttons complete all as specified and as directed
Supply and fix RED, YELLOW, GREEN, BLUE, AMBER & WHITE LED Indication Lamps Range (24 - 240 V ac/dc) for the existing HT VCB/OCB/RMU 11 KV Panels for including taking out old unserviceable Lamps complete all as specified and as directed
Supply and fix HRC Fuses for the existing HT VCB/OCB/RMU 11 KV Panels for including taking out old unserviceable Fuses complete all as specified and as directed
2 Amps capacity
6 Amps capacity
10 Amps capacity
16 Amps capacity
M & L in Replacement of unserviceable existing make and model IDMT relay numerical non directional over current and earth fault relay with communication feature (RS 485) with full automation system type Argus, Aux voltage 110 volt DC should comprise of the following feature :- (a) Three phase over current and one earth fault (b) High set - low set (c) RS-485 with full communication system (d) Multi characteristic for both over current and earth fault, Make: L&T / SCHNEIDER / ABB / C&S / EASUN REYROLLE
Supply and fix Trip-Neutral-Close (TNC) Switch, fixing with the existing HT VCB/OCB 11 KV Panel for including taking out old unserviceable TNC Switch complete all as specified and as directed. Make: Kaycee / L&T / Salzer / Vaishno
Supply & Fix of Multi Data Meter, measuring Voltage, Current, PF, HZ, KWH, KVAH, KVARH for out going various feeders to different Labs including complete wiring , testing all as specified and directed Make: SCHNEIDER / ELMEASURE
Material and labour for replacement of Digital volt meter 11 KV 3 phase range of accuracy 0.5 complete all as specified and directed.
Material and labour for replacement of Digital Amper meter 11 KV 3 phase range of accuracy 0.5 complete all as specified and directed.
Supply and fix DC power pack 230 V AC Input & output 110 / 30 V DC for energizing tripping and closing coil installed in VCB/OCB complete tesing including taking down old unserviceable DC power pack all as specified and directed.
Supply and fix heat shrinkable HT 11KV out door type cable end termination suitable for XLPE cable of 3 core 185 sq mm earth system with necessary jointing material and labour termination kit including connection etc complete all as specified and as directed. Make: RAYCHEM/MSEAL/DENSON
M & L for Cable jointing kit for 11 KV (Earthed) grade cable for straight through heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 185 sq mm complete all as specified and as directed. Make: RAYCHEM/MSEAL/DENSON
Supply and fixing GI pipe light grade 100 mm dia for protection of HT/LT cable under road or on wall all as specified and directed .
Supply, installation. connecting electrically and commissioning switch air break, gang operated, tripple pole copper type mounted on insulators 15 Nos with operating mechanism, drop out fuse, for current rating 800 Amps and working voltage 66000 volts including taking down old unserviceable switch air break, gang operated complete all as specified and directed.
Supply, installation. connecting electrically and commissioning switch air break, gang operated, tripple pole mounted on insulators 15 Nos and steel frame with operating mechanism in worked from ground level, drop out fuse, for current rating 400 Amps and working voltage 11000 volts including taking down old unserviceable switch air break, gang operated complete all as specified and directed.
M&L required for locating fault in U/G HT cable by using fault detector machine including transportation and by carring out high voltage test all as directed by Engr-in-charge
Supply and fix in replacement MD XL type 15 KVAR capacitor 440 volt, 3 Phase, , voltage test between terminals 1.75 rated volt including taking out u/s all as directed by Engs-in -charge. Make- Neptune, SIMENS, L&T, EPCOS
Supply and fix in replacement MD XL type 25 KVAR capacitor 440 volt, 3 Phase, , voltage test between terminals 1.75 rated volt including taking out u/s all as directed by Engs-in -charge. Make- Neptune, SIMENS, L&T, EPCOS
Supply and fixing of MCCB, TP, 415 V, fixed type, 63 Amps with breaking capacity 16 KA
Supply and fixing of APFC Relay 12 Stage
Supply and fixing Dgital Display Voltmeter suitbale for the existing Capacitor Panel including necessary connections and taking out old unservicebale complete all as specified and as directed. Make : Schneider / Elmeasure / AE / MECO
Supply and fixing Dgital Display Ammeter suitbale for the existing Capacitor Panel including necessary connections and taking out old unservicebale complete all as specified and as directed. Make : Schneider / Elmeasure / AE / MECO
Material and labour for Calibration of Relays through secondary injection method and testing complete relays like IDMT relays instantaneous earth fault relays on HT OCB panel/VCB panel control SF6 breaker panel and control relay panel etc submitting reports all as directed by Engs-in -charge. Note: (i) Quarterly checking and calibration of all relays fixed in VCB, OCB, SF6 breaker for smooth functioning included in the scope of work. (ii) During quarterly checking all tripping/setting to be ensured for proper functioning of relay/breaker
Material and labour for Testing of HT current tranformer (set of three) through primary injection method and also checking the connected panel wiring meters, checking equipment and also checking relays and tripping system and closing operation of HT OCB/VCB complete all as specified and as directed
Supply & Fix in replacement of spring charging motor for 11 KV VCB suitable for the existing make including taking out old unserviceable one.
Material and labour for preparation of old painted surfaces and cooling coils/fins of transformers of following capacities by removing oil marks using chemical or hot blow lamp. Spray painting to prepared surfaces using synthetic enamel paint of superoir quality of colour as approved as per standard engineering practice with two coats including painting the remaining iron parts i.e. supporting angles, XPM jali etc and white wash the transformer plateform with two coats. Writing SM No, MES No, Make and capacity with white paint having height not less than 2.5 cm and width not less than 1 cm all as required and directed.
Up to 200 KVA
above 200 KVA upto 500 KVA
above 500 KVA upto 1000 KVA
above 500 KVA upto 1000 KVA
Material and labour for stone graded course aggregate of 63 mm grade nominal size without any vegitation or chemical including levelling /spreading surrounding HT/LT 2/4 pole structure, LT/HT panel complete all as specified directed .
Material and labour for stone graded course aggregate of 40 mm grade nominal size without any vegitation or chemical including levelling /spreading surrounding HT/LT 2/4 pole structure, LT/HT panel complete all as specified directed .
Material and labour for cutting, removing the vegetation growth and surface dressing all around the installation yard/transformer/LT panel Board areas external only to keep always installation clean and tidy. Note: All the installation yards/area shall be kept clean throught contract period by repeatedly by remaining the grass/shrubs as many time reqd depending on the growth of grass measurement will be measured and paid only once throughout contract period.
Material and labour for servicing of two pole, structure complete including replacement of unserviceable jumper, sleeve vice type connector GI Clamps 'T' connector run connector run through clamps, bolts nuts washer connecting lugs/thimbles knife, contacts applying Petrolium jelly to the moving as well fixed contacts, tightening all the connection for its smooth functioning and preparing old painted surface of the structure such as poles, cross arms, bracing and supports clamps back plate complete painting of one coats of anti corrosive aluminium paint complete all as specified and directed. Marking the pole No/feeder name with black enamell paint complete all as specified and directed. Note: No Extra payment will be made for the spares reqd to keep the two pole structure in satisfactory functioning state throughout contract period other then given in schedules.
Material and labour for servicing of four pole, structure complete including replacement of unserviceable jumper, sleeve vice type connector GI Clamps 'T' connector run connector run through clamps, bolts nuts washer connecting lugs/thimbles knife, contacts applying Petrolium jelly to the moving as well fixed contacts, tightening all the connection for its smooth functioning and preparing old painted surface of the structure such as poles, cross arms, bracing and supports clamps back plate complete painting of one coats of anti corrosive aluminium paint complete all as specified and directed. Marking the pole No/feeder name with black enamell paint complete all as specified and directed. Note: No Extra payment will be made for the spares reqd to keep the four pole structure in satisfactory functioning state throughout contract period other then given in schedules
Material and labour for preventive maintenance/repairs to transformer step down 11 KV/0.433 KV of any type 250 to 1000 KVA of any make including cleaning the transformers externally throughly with lint free cloth, tightening the HT/LT terminal nuts, opening the top cover and replacing the perished gasket of top cover, replacing sight glass, replacing silca gel, replacing the worn out copper alloy nuts and tighting the earth terminals complete all as specified and directed.
Material and labour for earthing with steel earth plate electrode of size 60x60cmx6mm thick buried directly in ground to a depth not less than 2.25 mtr deep below normal ground level with top edge of the earth plate not less than 1.5 mtr deep below normal ground level connected to galvanized iron strip of size 32 X 6mm as earthing lead by means of nuts, bolts and washers of steel after welding of GI strip to earth electrode to the full lenght of earth plate,40mm dia GI tubing light grade protection pipe upto test point, 20mm dia GI watering pipe with funnel and wire mesh, PCC pit 1:3:6 with pit cover of size 30X30cm made of RCC 1:3:6 with suitable handle,angle iron frame made of angle iron of size 40x40x4mm, adequate qty of charcoal dust and salt layers all around the earth plate, removal of surplus soil and returning filling in all as required at site including test point made out of steel plate of size 75x75x6mm fixed to wall all as specified in plate No 3 of SSR Part-I and directed.
Material and labour for earthing with copper earth plate electrode of size 60x60cmx3.15mm thick buried directly in ground to a depth not less than 2.25 mtr deep below normal ground level with top edge of the earth plate not less than 1.5 mtr deep below normal ground level connected to copper strip of size 20X3 mm as earthing lead by means of nuts, bolts and washers of copperl after welding of copper strip to earth electrode to the full lenght of earth plate,40mm dia GI tubing light grade protection pipe upto test point, 20mm dia GI watering pipe with funnel and wire mesh, PCC pit 1:3:6 with pit cover of size 30X30cm made of RCC 1:3:6 with suitable handle,angle iron frame made of angle iron of size 40x40x4mm, adequate qty of charcoal dust and salt layers all around the earth plate, removal of surplus soil and returning filling in all as required at site including test point made out of steel plate of size 75x75x6mm fixed to wall all as specified in plate No 3 of SSR Part-I and directed.
Maintenance and servicing of battery panel 220/110/30/24 V DC with battery 55 Nos and its control Panels wiring, PCB, Relays and terminal cables with replacement of defective parts
Supply only rubber mat of 1 meter x 5 or 10 meter x 10 mm complete all as specified and directed.
Supply only rubber hand glove suitable for 11 KV complete all as specified and directed.
M&L for repair/replacement of Mild steel work for MS cable tray HV/LV type fixed on wall/bridge type with necssary support as per site requirment and duly painted with two coats of synthetic enamel paint over a coat of red oxide at E-type and CASDIC sub stations complete all as specified and directed by Engineer-in-Charge
Supply and fixing MS galvanised chain link fencing, of size 4mm dia and mesh size 100x100mm to any type of standards, rails, straining bolts etc including provision of binding mix for making fencing around the transformer/MES Installation complete all as specified and directed
M & L for repair to foundations of transformers/RMUs using PCC 1:2:4 type B1 (using 20 mm graded crushed stone aggregate) complete all as directed.
KARTHIK INCORPORATE
RAHUL ENTERPRISES
V.R.Enterprises
Lucky Enterprises
HEERA CONSTRUCTION CO.
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .