Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹3.1 CrAccepted-Finance | ₹3.1 Cr | 1 | Accepted-Finance Won in lottery |
| 2 | 2₹3.1 CrRejected-Finance | ₹3.1 Cr | 2 | Rejected-Finance Lost in lottery |
| 3 | 2₹3.1 CrRejected-Finance | ₹3.1 Cr | 2 | Rejected-Finance Lost in lottery |
| 4 | 2₹3.1 CrRejected-Finance | ₹3.1 Cr | 2 | Rejected-Finance Lost in lottery |
| 5 | 2₹3.1 CrRejected-Finance | ₹3.1 Cr | 2 | Rejected-Finance Lost in lottery |
Updated dates
Tender Value
₹3.1 Cr
EMD Value
₹3.1 L
Closing Date
19 Jan 2026, 5:00 pmClosed
CCE (RandB) CIRCLE, BALANGIR
O/O CCE (RandB) CIRCLE, BALANGIR
Building work
2025_EICCL_123711_1
CCE(R and B)BGR-15-2025-26
National Competitive Bid
Civil Works - Buildings
270 days
Balangir
Please refer Tender documents.
4 documents required · 4 mandatory
₹10,000
₹3.1 L
Yes
17 Apr 2026
23 Dec 2025
20 Jan 2026
23 Dec 2025
19 Jan 2026
23 Dec 2025
23 Dec 2025 - 19 Jan 2026
CIVIL WORK Earth work in excavation in foundation trenches, column foundation, pit, etc in all kind of soil including moorum stony earth and gravel mixed with boulders except sheet rock and boulders not requiring blasting including dressing of sides and levelling the bed up to the required depth and depositing the excavated materials away from the work site with initial lead of 50 mtr and all lifts, including shoring, shuttering & dewatering (if required) with cost of labour, labour cess, hire & running charges of all machineries, sundries & T&P required for the work complete as directed by the Engineer in charge. Upto 1.5mtr Depth
Beyond 1.5mtr to 3.00 mtr Depth
Filling the Foundation and Plinth, Sides of Foundation, etc. with excavated materials (excluding rock), in layers not exceeding 0.225 m in depth including cost of watering, ramming, dressing and levelling the top to proper level & gradient, cost of labour, conveyance, loading, unloading, T&P, etc, all complete as per the direction of Engineer-in-Charge. Ground Floor
Disposal of surplus/ excavated materials by mechanical means within 5km. Lead away from the site including cost of all labour , T&P complete as per the direction of the Engineer-in-charge. Ground Floor
Supplying, diluting and preparing chemical emulsion like Imidacloprid 30.5 % SC or other chemicals approved by Central Insecticides Board or as directed by the manufacturer and spraying the mixture uniformly by sprayer as Pre-Constructional Anti-termite Treatment confirming to IS 6313 (Part-II) and creating a chemical barrier under and around the column pits, wall trenches, basement excavation, top surface of plinth filling, junction of walls and floors along with external perimeter of the building, expansion joints, surrounding the pipes and conduits etc. at the rate of 7.5 liters per sqm on vertical surface and 5.0 liters per sqm on horizontal surfaces, 50% of the emulsion to be filled in the holes made in trenches at 150mm center to center (or as directed by the manufacturer) including the cost of all materials, cost of all labour, conveyance, loading, unloading, T&P, etc. all complete as per the direction of Engineer-in-Charge. ( The payment shall be made on the basis of actual plinth area of the building at ground floor and vertical faces will not be measured for payment). Note- The contractor shall have to furnish Ten (10) years guarantees to maintain the anti-termite treated area / structure free from termite. In addition to the 10 years guarantee furnished as above, the contractor shall have to furnish ten years (after certificate of final completion) Bank Guarantee Bond issued by any Nationalized Bank executed in favour of the client as directed in the prescribed proforma available in the tender document for an amount of 10% (ten percent) of cost of this item of work.
Supplying and Filling with Sand in Foundation and Plinth in layers not exceeding 20 cm in depth, well watered and compact , top surface dressed and levelled to proper level and gradient including cost of all materials , conveyance, royalties, loading, unloading, cost of all labour, T&P, etc.All compelete as per the dirrection of Engineer-in-charge. Ground Floor
PCC WORK Providing and lying Plain Cement Concrete of proportion (1:3:6) in foundation & floor using 40 mm & down grade black hard crusher broken granite stone metal, washed and screened sharp sand of approved quality from approved quarry including hoisting, lowering, laying the concrete, ramming, watering and curing etc. complete to required thickness including cost of all materials, conveyance, loading, unloading, royalties, cost of labours, T&P, hire & running charges of concrete mixer, etc. all complete as per the direction of the Engineer -in -charge. Ground Floor
Beyond 1.5 M to 4.5M Depth
RCC WORK Providing, lifting, hoisting and laying in position machine batched , machine mixed and machine vibrated design mix cement concrete of M-25 Including the cost of Centering and Shuttering (minimum cement content not less than 403 Kg/Cum) grade in reinforced cement concrete structural elements using black hard crusher broken granite chips of approved quality from approved quarry including mixing and compacting to proper shape and size, level and plumbs and finishing the exposed surfaces smooth including the cost of all materials, cost of labour, conveyance,loading, unloading, royalties, watering and curing for the required period, T&P , hire & running charges of concrete mixer and vibrator, cost of Admixtures in recommended proportions ( as per IS 9103 ) to accelerate, retard setting of concrete, improve workability without impairing strength and durability etc. complete as per the direction of the Engineer-in-charge but excluding the cost of steel reinforcement. R.C.C. foundation and footing bases of columns mass concrete pre-cast slab etc. Beyond 1.5 M to 4.5M Depth
R.C.C. Plinth Beam Ground Floor
R.C.C. Beams, columns, grider and bressmer etc. Ground Floor
First Floor
Second Floor
Terrace Floor
R.C.C. Floor and Roof slab, landing, balconies,Projecting sun shades and chajjas up to 4.3Mtr. Height. Ground Floor
First Floor
Second Floor
Terrace Floor
R.C.C. stairs excluding landing but including railing. Ground Floor
First Floor
Second Floor
R.C.C. Lintel Ground Floor
First Floor
Second Floor
Terrace Floor
Providing & fixing TOR Fe-500 HYSD Reinforcement bars of required diameter and approved quality for Reinforced Cement Concrete work including straightening, cutting, bending, binding, welding(if approved) , joining (if necessary), tying the grills, hoisting, lowering and placing in position as per the approved design & drawings (BBS) with provision of standard fan hooks including the cost of all materials, cost of all labour, conveyance, loading, unloading, cost of binding wires of 18 to 20 gauge, T&P, etc, all complete as per the direction of Engineer-in-Charge. Note: (Linear measurements will be taken & quantity will be calculated on standard weight. Lap length of bars & Weight of binding wire will not be considered for measurement and payment). Ground Floor
First Floor
Second Floor
Terrace Floor
BRICK WORK Providing and laying Brick Masonry work in Foundation & Plinth using Fly ash bricks of 23 Cm. x 11 Cm. x 8 Cm. size having crushing strength not less than 75 Kg./Cm2 with dimensional tolerance + 2 % confirming to IS 12894 and IS 2212 in cement mortar (1:6) affter immersing the bricks for minimum 6 hours in water before use, with all necessary projections, splays cutting, circular moulding, corbelling, etc. as per the drawings including the cost of all materials, cost of all labour, conveyance, royalties, loading, unloading, scaffolding, staging, watering and curing, sundries, T&P, etc. complete as per the direction of the Engineer-in-charge. Ground Floor
Providing and laying Brick masonry work in Superstructure using Fly ash bricks of 23 Cm. x 11 Cm. x 8 Cm. size having crushing strength not less than 75 Kg./Cm2 with dimensional tolerance + 2 % confirming to IS 12894 and IS 2212 in cement mortar (1:4) for Half Brick Masonry Wall with provisions for 2 nos 6mm dia MS bar at each 4th layer after immersing the bricks for minimum 6 hours in water before use, with all necessary projections, splays cutting, circular moulding, corbelling, etc. as per the drawings including the cost of all materials, cost of all labour, conveyance, royalties, loading, unloading, scaffolding, staging, watering and curing, sundries, T&P, etc. complete as per the direction of the Engineer-in-charge. ( Excluding Cost Of Steel Reinforcement ) Ground Floor
First Floor
Second Floor
Providing and laying of Full Brick Masonry work in Superstructure using Fly ash bricks of 23 Cm. x 11 Cm. x 8 Cm. size having crushing strength not less than 75 Kg./Cm2 with dimensional tolerance + 2 % confirming to IS 12894 and IS 2212 in cement mortar (1:6) affter immersing the bricks for minimum 6 hours in water before use, with all necessary projections, splays cutting, circular moulding, corbelling, etc. as per the drawings including the cost of all materials, cost of all labour, conveyance, royalties, loading, unloading, scaffolding, staging, watering and curing, sundries, T&P, etc. complete as per the direction of the Engineer-in-charge. Ground Floor
First Floor
Second Floor
Terrace Floor
FINISHING WORK Providing 6 mm thick Cement Plaster in Cement Mortar of (1:4) to Ceilings of Roof Slabs, Stairs, Landings, Chajja, Shelves, Columns, Beams and Lofts etc. including roughening, scraping and cleaning and finishing the plastered surface smooth using wooden floats only to proper plumbs and level, making grooves, beads and drip coarse to give required ornamental finish as per drawings including cost of all materials, conveyance, loading and unloading and royalties, all labour, scaffolding, watering and curing , sundries, T&P etc. complete as per direction of the Engineer-in-charge Ground Floor
First Floor
Second Floor
Terrace Floor
Providing 12mm thick cement plaster in cement mortar (1:4) to the surface of half brick masonry wall including racking out joints, scraping and cleaning the surface and finishing the plaster surface smooth using wooden floats, bars, etc only to proper plumbs and level and making grooves, beads and drip coarse to give required ornamental finish as per drawings including cost of all materials, conveyance, loading and unloading, royalties, cost of all labour, scaffolding, staging, watering before plastering and curing, sundries and T&P, etc. complete as per direction of the Engineer-in-charge. Ground Floor
First Floor
Second Floor
Providing 12mm thick Cement Plaster to the Surface of Brick Masonry Wall in Cement Mortar (1:6) including racking out joints, scraping and cleaning the surface and finishing the plaster surface smooth using wooden floats only to proper plumbs and level and making grooves, beads and drip coarse to give required ornamental finish as per drawings including cost of all materials, conveyance, loading and unloading and royalties, all labour, scaffolding, watering and curing, sundries and T&P etc. complete as per direction of the Engineer-in-charge. (Inside Even Surface) Ground Floor
First Floor
Second Floor
Terrace Floor
Ground Floor
First Floor
Second Floor
Providing 18mm thick cement plaster on external surfaces of brick surfaces in two coats consisting of under layer 12mm thick in CM 1:6 (1 cement : 6 coarse sand) and top layer of 6mm thick cement plaster 1:4 ( 1 cement : 4 coarse sand) mixed with integral water proofing material of including racking out joints, scraping and cleaning the surface and finishing the plaster surface smooth using wooden floats only to proper plumbs and level and making grooves, beads and drip coarse to give required ornamental finish as per drawings including cost of all materials, conveyance, loading and unloading and royalties, all labour, scaffolding, watering and curing, sundries and T&P etc. complete as per direction of the Engineer-in-charge. Ground Floor
First Floor
Second Floor
Terrace Floor
PLINTH PROTECTION Providing, lifting, hoisting and laying in position machine batched , machine mixed and machine vibrated approved design mix Reinforced Cement Concrete of grade M-20 in reinforced cement concrete structural elements using black hard crusher broken granite chips of approved quality, size and grading obtained from approved quarry including mixing and compacting to proper shape and size, level and plumbs and finishing the exposed surfaces smooth including the cost of all materials, cost of all labour, conveyance, royalty, loading, unloading, watering, curing, sundries, hire & running charges of machineries, cost of admixture in recommended proportions ( as per IS 9103 ) to retard/accelerate the setting time of concrete, improve workability without imparting the strength and durability, etc. all complete as per the direction of the Engineer-in-charge.(but excluding the cost of reinforcement, centering and shuttering.) Ground Floor
Providing average 25mm thick grading Concrete in C.C ( 1:2:2 ) using 6mm size crusher broken black hard granite chips using 2% water proofing cement compound (Make: Sika / Fosroc / Equivalent) after scraping and cleaning the roof surface and finishing smooth to proper slope and gradient including cost of all materials, conveyance, sundries,T&P watering and curing by ponding water over terrace slab etc. complete as per the direction of the Engineer-in-charge. First Floor
Second Floor
Terrace Floor
Terrace Water Proofing Providing and installing two component acrylic modified cementitious waterproofing coating over roof slab after carrying out pond test on roof slab, filling all defects, saturating the surface, mixing the products and then application in 2.0 mm thickness (1.8 Kg / sqm coverage rate for 1.0 mm thickness) in suitable layers complete in all respect, all materials, tools, plant & labour complete in all respect. Density 1850kg/m³ , Mix ratio (Powder to liquid) 3:1 by weight ,Water penetration Din 1048 1.5 Bar no leakage Potlife @ 25°C 2 hours & @ 40°C 30 minutes,Recoatable: 8-12 hours Elongation >42% (air) & >31% (under water),Tensile strength >20 kg/cm2 ,VOC content (HK prod code P10-17) 0.5 g/L including cost of all materials, conveyance, taxes and sundries,T&P, watering and curing by ponding water over terrace slab etc. complete as per the direction of the Engineer-in-charge.(Make:BASF/Fosroc/SIKA/MAPEI/MYK) First Floor
Second Floor
Terrace Floor
FINISHING WORK Supplying and finishing the plastered surface of wall using Cement Based Wall Putty (Water Based) of approved make and quality and finished smooth and even surface to receive the paint including the cost of all materials, cost of all labour, conveyance, taxes, loading, unloading, scaffolding, T&P, etc, all complete as per the direction of Engineer-in-Charge. (Make: Birla White/J K Wall Putty) (i) Inside Putty Ground Floor
First Floor
Second Floor
Terrace Floor
(ii) Outside Putty Ground Floor
First Floor
Second Floor
Terrace Floor
Providing and applying Two Coats Plastic Emulsion Paint of approved make, quality and shade over a coat of wall primer of approved quality to the internal plastered surfaces including throughly brushing the surface to make free from foreign materials, sand papering, priming including cost of all materials, cost of all labour, conveyance, loading, unloading, scaffolding, staging, watering and curing, T&P etc. complete as per the direction of the Engineer-in-charge. (Note: Colour & shade to be approved before procurment & use).(Make:Dulux/Nerolac/Berger/Asian Paint) Ground Floor
First Floor
Second Floor
Terrace Floor
Providing and Painting with Two Coats Weather Coat Paint (exterior grade) of approved make & shade manufactured by reputed manufacturer make an even finished surface over a coat of water bound cement primer in all heights with all scaffolding and staging charges including cost, conveyance, cost of all labours, T & P, sundries etc. as required for the work complete. (Note: Colour & shade to be approved before procurment & use).(Make:Dulux/Nerolac/Berger/Asian Paint) Ground Floor
First Floor
Second Floor
Terrace Floor
Providing and painting Two Coats of Synthetic Enamel Paint of approved quality, brand and shade over a coat of red oxide primer to Iron Work including cost, conveyance, royalties , cost of all labour, labour cess, T&P etc. required for the work complete as directed by the Engineer-in-Charge. (Note: Colour & shade to be approved before procurment & use).(Make:Dulux/Nerolac/Berger/Asian Paint) Ground Floor
First Floor
Second Floor
Terrace Floor
FLOORING WORK Providing and laying of 600 mm x 600 mm Matt Finished Vitrified Floor Tiles confirming to IS : 15622 of approved make, quality and colour without any warpage laid over an under layer of 20 mm thick base of cement mortar (1:4) (1 cement: 4 coarse sand) including cutting to size, laying and filling the joints with white cement slurry mixed with colouring pigment to match the shade and colour, cleaning the surfaces including the cost of all materials, cost of all labour, conveyance, royalties, loading, unloading, sundries, watering and curing, T&P, etc. complete as per the direction of the Engineer-in-Charge. (Note- Sample of tiles shall be approved before procurement and use.) (Make:Somany/Jhonson/RAK/Kajaria) Ground Floor
First Floor
Second Floor
Providing and laying of Vitrified Tiles in dado/skirting confirming to IS : 15622 of approved make, quality, colour and size 600mm x 600mm upto required height from floor level fixed over an under layer of 12mm thick bed of cement mortar (1:3) (1 Cement : 3 Coarse sand) including cutting to size, laying and filling the joints with white cement slurry mixed with colouring pigment to match the shade and colour, cleaning the surfaces including the cost of all materials, cost of all labour, conveyance, taxes, royalties, loading, unloading, sundries, watering and curing, T&P, etc. complete as per the direction of the Engineer-in-Charge. (Note- Sample of tiles shall be approved before procurement and use.) Ground Floor
First Floor
Second Floor
Providing and laying of Floor Master SPC Flooring, Series - "AQUA LUX" Thickness - 5mm(4+1) or Eqv., along with a cushion backing, no extra foam required. Size 228*1220mm. Waterproof, Termite Proof Glueless, locking with 0.3mm wear layer for heavy (Class-34) and moderate commercial use. The suggested material is free from any Led &/or Pthalate components. Slip resistance >R9. Castor chair resistance to EN>25,000 cycles. Skirting & profile at transition areas of same colour including the cost of all materials, cost of all labour, conveyance, loading, unloading, sundries, T&P, etc. complete as per the direction of the Engineer-in-Charge. (Note- Sample shall be approved before procurement and use.) (Make:Floor Master - Aqua Lux/Square foot/Eqv.) First Floor
Providing & laying granite stone flooring using 19-20 mm thick granite stone slab of approved quality, colour and size above 0.4 Sqm as per IS 14223 in Stair Treads and Risers over an under layer of 20 mm thick cement mortar (1:4) (1 cement: 4 coarse sand) confirming to IS-1443 including cutting to size, laying and joining with white cement slurry and colouring pigment to match the shade with typical half nosing and cutting grooves etc including cost of all labour, materials, royalties, loading and unloading, conveyance, sundries, watering and curing, etc. complete as per the direction of the Engineer-in-Charge. (Note- Sample of granite tiles shall be approved before procurement and use.) Ground Floor
First Floor
Second Floor
Providing & laying granite stone flooring in Floors and landing using 19-20 mm thick granite stone slab of approved quality, colour and size above 0.4 Sqm as per IS 14223 laid over an under layer of 20 mm thick cement mortar (1:4) (1 cement: 4 coarse sand) confirming to IS-1443 including cutting to size, laying and filling the joints with white cement slurry mixed with colouring pigment to match the shade and colour, cleaning the surfaces including the cost of all materials, cost of all labour, conveyance, royalties, loading, unloading, sundries, watering and curing, T&P, etc. complete as per the direction of the Engineer-in-Charge. (Note- Sample of granite tiles shall be approved before procurement and use.) Ground Floor
First Floor
Second Floor
Terrace Floor
providing & laying granite stone tiles in dado/skirting using 10mm thick granite stone slab of approved quality, colour and size upto 0.4 Sqm as per IS 14223 to proper line, level and slope laid over 12mm thick cement mortar (1: 3) confirming to IS IS-1443 including cutting to size, laying and filling the joints with white cement slurry mixed with colouring pigment to match the shade and colour, cleaning the surfaces including the cost of all materials, cost of all labour, conveyance, royalties, loading, unloading, sundries, watering and curing, T&P, etc. complete as per the direction of the Engineer-in-Charge. (Note- Sample of granite tiles shall be approved before procurement and use.) Ground Floor
First Floor
Second Floor
Terrace Floor
Levelling Course R.C.C. work of M-15(1:2:4) grade with 20mm and down grade black hard granite (crusherbroken) stone chips including hoisting and laying. Ground Floor
BUILT IN JOINERIES Providing and fixing ISI marked 35 mm thick flush door shutters conforming to IS : 2202 (Part I) decorative type, core of block board construction with frame of 1st class hard wood and well matched teak three ply veneering with vertical grains or cross bands and face veneers on both faces of shutters of approved design including cost of all door fittings and fixtures etc. complete. Ground Floor
First Floor
Second Floor
Terrace Floor
Providing and fixing 65mm X 125mm factory made single extruded WPC (Wood Polymer Composite) solid door/window/Ceosetory windows & other Frames/Chowkhat comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2, modulus of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixed in position with M.S hold fast/lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-In- Charge. (Make: WPC Door Frame: Century/Black Cobra/Rajshri Plastiwood) Note: For WPC solid door/window frames, minus 5mm tolerance in dimensions i.e depth and width of profile shall be acceptable. Variation in profile dimensions on plus side shall be acceptable but no extra payment on this account shall be made. Ground Floor
First Floor
Second Floor
Terrace Floor
Providing and fixing of 12mm thick Clear Toughened Glass Frameless Door With Dorma Premium Fittings.Dorma Premium (9111198) Unilite Package BTS 75,UL PT 10 with Cover,UL PT 20 with Cover,UL US 10 Luck with Cover and PT 24,Dorma Premium (9137121) H Type Handle 450mm,12mm Clear Toughened Glass with Cutout and Hole, including the cost of all materials, hardware fittings, cost of all labour, conveyance, loading, unloading, T&P, etc, complete as per the direction of Engineer-in-Charge. In all Floor
Supplying and installing Aluminium System - Fixed windows made out of ALUPURE/ WINPLUS/ ALTECH/REKLAD make frame dimension of 39mm x 42mm for with corners mechanical joints. Aluminium Systems are extruded through Billets with 6063 T6 Grade and 6mm thick toughen frosted glass with complete wind load calculation as per IS:875(part-3). Almost unlimited choice of colours due finishing techniques such as anodising and powder finishing. The system can accomodate Forsted glass with 4/5/6/8/10/12/14/20 & 22mm. The profile manufacturer should have an authorised fabrication partner for windows assembling and installation. The windows must be installed complete with all kinds of ironmongery (including EPDM gaskets,bridging wedges and glass packers) and with suitable water draining system. Application of Silicon sealant from Inside / Outside of MCCOY /Dowcorning or equivalent. OR Supplying and installing Aluminium System - Openable windows made out of ALUPURE/ WINPLUS/ ALTECH/REKLAD make frame dimension of 39mm x 62.9mm & Sash dimension of 46mm x 92mm for with corners mechanical joints. Aluminium Systems are extruded through Billets with 6063 T6 Gradeand 6mm thick toughen frosted glass with complete wind load calculation as per IS:875(part-3). Almost unlimited choice of colours deu to finishing techniques such as anodising and powder finishing. The system can accomodate Forsted glass with 4/5/6/8/10/12/14/20 & 22mm. The profile manufacturer should have an authorised fabrication partner for windows assembling and installation. The windows must be installed complete with all kinds of ironmongery (including EPDM gaskets,bridging wedges and glass packers) and with suitable water draining system. Application of Silicon sealant from Inside / Outside of Dowcorning / GE or equivalent.OR Supplying and installing Aluminium System - Sliding windows made out of ALUPURE/ WINPLUS/ ALTECH /REKLAD make frame dimension of 88mm x 40 & Sash dimension of 31mm x 61.5mm for with corners mechanical joints. Aluminium Systems are extruded through Billets with 6063 T6 Grade and 6mm thick toughen frosted glass with complete wind load calculation as per IS:875(part-3). Almost unlimited choice of colours due to finishing techniques such as anodising and powder finishing. The system can accomodate Forsted glass with 4/5/6/8/10/12/14/20 & 22mm. The profile manufacturer should have an authorised fabrication partner for windows assembling and installation. The windows must be installed complete with all kinds of ironmongery (including EPDM gaskets,bridging wedges and glass packers) and with suitable water draining system. Application of Silicon sealant from Inside / Outside of Dowcorning / GE or equivalent. Ground Floor
First Floor
Second Floor
Terrace Floor
Supplying, fitting & fixing of M.S. Grill made out of M.S. flats/square bars as per drawing and design fixed in position to proper plumb, including a coat of priming with approved quality metallic primer, materials including cost, conveyance, transportation of all materials, cost of all labour, sundries, T&P etc. complete as per direction of Engineer in charge. Ground Floor
First Floor
Second Floor
Terrace Floor
S.S Railing Supplying, fabricating & fixing of polished stainless steel (304 grade) items made out of pipes, angles, flats, plates, hollow tube, square pipe bracing as per approved design and specification, buffing, polishing etc. with cost, conveyance, labour in railing, parapet, staircase, space frame etc required for the work complete in all respect as per direction of Engineer-in-charge. Ground Floor
First Floor
Second Floor
Terrace Floor
Cladding and Structural Glazing Providing and fixing Glass Reinforced Concrete (G.R.C) Screens in approved size, pattern, design, shadeand thickness of 50mm on frame and design element in 30mm thick have weight approximately between 3.5 – 4 Kg per Sq. Ft. and color of M/S UniStone make or equivalent. The above weight and thickness is considering dimensions of screens up to 2133mm in height and 1219mm in width and having at least 50% void space. The screens should be made from ‘53 grade’ White Portland Cement manufactured by ‘JK Cement’ or equivalent, Quartz, Fine Silica Sand, Alkali Resistant Glass Fiber manufactured by ‘N.E.G JAPAN’ or equivalent, Super Plasticizers manufactured by ‘BASF’ or equivalent, Polymers manufactured by ‘BASF’ or equivalent and U.V resistant Synthetic inorganic pigments should be used for pigmentation manufactured by ‘BAYFERROX (Germany)’ or equivalent. The material casting should take place in FRP Molds. The fixing of Screens should be ‘Dry fixing’ i.e. to be done with M.S Galvanized Clamps, fixtures and fasteners of Hilti / Fischer.
Structural Glazing Providing and supplying aluminium extruded tubular and other aluminium sections as per the architectural drawings and approved shop drawings , the aluminium quality as per grade 6063 T5 or T6 as per BS 1474,including super durable powder coating of 60-80 microns conforming to AAMA 2604 of required colour and shade as approved by the Engineer-in-Charge. (The item includes cost of material such as cleats, sleeves, screws etc. necessary for fabrication of extruded aluminium frame work. Nothing extra shall be paid on this account).
Designing, fabricating, testing, protection, installing and fixing in position semi (grid) unitized system of structural glazing (with open joints) for linear as well as curvilinear portions of the building for all heights and all levels, including: Structural analysis & design and preparation of shop drawings for the specified design loads conforming to IS 875 part III (the system must passed the proof test at 1.5 times design wind pressure without any failure), including functional design of the aluminum sections for fixing glazing panels of various thicknesses, aluminium cleats, sleeves and splice plates etc. gaskets, screws, toggles, nuts, bolts, clamps etc., structural and weather silicone sealants, flashings, fire stop (barrier)-cum-smoke seals, microwave cured EPDM gaskets for water tightness, pressure equalisation & drainage and protection against fire hazard including: Fabricating and supplying serrated M.S. hot dip galvanised / Aluminium alloy of 6005 T5 brackets of required sizes, sections and profiles etc. to accommodate 3 Dimentional movement for achieving perfect verticality and fixing structural glazing system rigidly to the RCC/ masonry/structural steel framework of building structure using stainless steel anchor fasteners/ bolts, nylon seperator to prevent bimetallic contacts with nuts and washers etc. of stainless steel grade 316, of the required capacity and in required numbers. Providing and filling, two part pump filled, structural silicone sealant and one part weather silicone sealant compatible with the structural silicone sealant of required bite size in a clean and controlled factory / work shop environment, including double sided spacer tape, setting blocks and backer rod, all of approved grade, brand and manufacture, as per the approved sealant design, within and all around the perimeter for holding glass. Providing and fixing in position flashings of solid aluminium sheet 1 mm thick and of sizes, shapes and profiles, as required as per the site conditions, to seal the gap between the building structure and all its interfaces with curtain glazing to make it watertight. Making provision for drainage of moisture/ water that enters the curtain glazing system to make it watertight, by incorporating principles of pressure equalization, providing suitable gutter profiles at bottom (if required), making necessary holes of required sizes and of required numbers etc. complete. This item includes cost of all inputs of designing, labour for fabricating and installation of aluminium grid, installation of glazed units, T&P, scaffolding and other incidental charges including wastages etc., enabling temporary structures and services, cranes or cradles etc. as described above and as specified. The item includes the cost of getting all the structural and functional design including shop drawings checked by a structural designer, dully approved by Engineer-in-charge. The item also includes the cost of all mock ups at site, cost of all samples of the individual components for testing in an approved laboratory, field tests on the assembled working structural glazing as specified, cleaning and protection till the handing over of the building for occupation. In the end, the Contractor shall provide a water tight structural glazing having all the performance characteristics etc. all complete as required, as per the Architectural drawings, as per item description, as specified, as per the approved shop drawings and as directed by the Engineerin- Charge. Note:- 1. The cost of providing extruded aluminium frames, shadow boxes, extruded aluminium section capping for fixing in the grooves of the curtain glazing and vermin proof stainless steel wire mesh shall be paid for separately under relevant items under this sub- head. However, for the purpose of payment, only the actual area of structural glazing (including width of grooves) on the external face shall be measured in sqm. up to two decimal places. Note:-2. The following performance test are to be conducted on structural glazing system if area of structural glazing exceeds 2500 Sqm from the certified laboratories accreditated by NABL(National Accreditation Board forTesting and Calibration Laboratories), Department of Science & Technologies, India. Cost of testing is payable separately. The NIT approving authority will decide the necessity of testing on the basis of cost of the work, cost of the test and importance of the work. Performance Testing of Structural glazing system Tests to be conducted in the NABL accredited lab or by any other accreditation body which operates in accordance with ISO/ IEC 17011 and accredits labs as per ISO/ IEC 17025.
Providing openable side / top hung vision glass panels (IGUs) in structural glazing including providing and supplying at site all accessories and hardwares for the openable panels as specified and of the approved make such as heavy duty stainless steel friction hinges, min 4 -point cremone locking sets with stainless steel plates, handles, buffers etc. including necessary stainless steel screws/ fasteners, nuts, bolts, washers etc. all complete as per the Architectural drawings, as per the approved shop drawings, as specified and as directed by the Engineer- in-Charge.
Providing, assembling and supplying vision glass panels (IGUs) in structural glazing comprising of hermetically-sealed 6-12- 6 mm insulated glass (double glazed) vision panel units of size and shape as required and specified, comprising of an outer heat strengthened float glass 6mm thick hard coated low emmissivity glass, of approved colour and shade with reflective soft coating on surface # 2 of approved colour and shade, an inner Heat strengthned clear float glass 6mm thick, spacer tube 12mm wide, dessicants, including primary seal and secondary seal (structural silicone sealant) etc. all complete for the required performances, as per the Architectural drawings, as per the approved shop drawings, as specified and as directed by the Engineer-in-Charge. The IGUs shall be assembled in the factory/ workshop of the glass processor.“(Payment for fixing of IGU Panels in the curtain glazing is included in cost of item No.26.2)“For payment, only the actual area of glass on face # 1 of the glass panels (excluding the areas of the grooves and weather silicone sealant) provided and fixed in position, shall be measured in sqm.“ (i) Coloured tinted float glass 6mm thick substrate with reflective soft coating on face # 2, + 12mm Airgap + 6mm Heat Strengthened clear Glass of approved make having properties as visible Light transmittance (VLT) of 25 to 35 %, Light reflection internal 10 to 15%, light reflection external 10 to 20 %, shading coefficient (0.25- 0.28) and U value of 3.0 to 3.3 W/m2 degree K etc. The properties of performance glass shall be decided by technical sanctioning authority as per the site requirement.
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes conforming to IS:15778, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge.(Make: Astral/Ashirabad) 20mm dia C - PVC pipe Ground Floor
First Floor
Second Floor
25mm dia C - PVC pipe Ground Floor
First Floor
Second Floor
32mm dia C - PVC pipe Top Floor
40mm dia C - PVC pipe Top Floor
Supplying all materials, labour T&P and fitting and fixing brass/CP fittings of the following nominal bore with supply of all joiniting materials including cost & conveyance of all materials to worksite, payment of taxes etc. all complete as per P.H specification and direction of the Engineer-in-charge. (Make: Cera/Jaquar) 15mm dia CP angle stop cock (Con-CHR-053KN Jaquar make)
15mm dia CP two in one bib cock (Con-CHR-041KN Jaquar make)
15 mm dia CP S.B. Bib cock(CON-CHR-037KN)
15mm dia CP Long Body Bib cock (Con-CHR-107KN Jaquar make)
15mm dia CP Pillar cock (Con-CHR-011KN Jaquar make)
25mm dia brass full way valve (Shakti make)
32mm dia brass full way valve (Shakti make)
40mm dia brass full way valve (Shakti make)
15mm dia CP Health faucet (Con-ALD-MCH-573 Jaquar make)
WALL MIXER WITH PROVISION FOR OVERHEAD Shower (FLR-ABR-5273UPR)
15mm CP Extension piece
125mm CP grating
15mm size C.P. flange
Supplying all materials , labour, T&P and fixing rotational moulded polyethylene cylindrical vertical water storage tanks conforming to IS:12701/1996 including cutting holes through the tank and fixing mild steel tubes and fittings and providing extra sockets and jam nuts, fixing ball valve etc. including hoisting upto a height of 5 metres above ground level and placing the tank to the required position and providing 5.40 mtr. lengthx0.25 mtr width KB brickwork in cement mortar (1:6) of 0.46m height in staging and 0.13mtr thick circular protection wall of 0.46mtr height to support the tank,12mm thick cement plaster in cement mortar (1:6) over brick work, RCC slab of size 1.60mX1.60m and 0.10m thick ,RCC beam of 0.25mx0.30m and 3.40m average length in cement concrete (1:2:4) using 12mm size crusher broken hard black granite chips and required steel reinforcement including centering and shuttering,watering,curing ,cost of all materials,conveyance of all materials to worksite , payment of royalty, all taxes etc.all complete as per approved drawing , P.H. specification and direction of Engineer-in-charge. (Make: Astral/Syntex) 2000 liters capacity PVC water storage tank roof of 2nd floor
supplying all materials, labour, T&P and cutting holes through existing brick work including making good the damages in cement mortar (1:4) for taking G.I. Pipes and fittings/ P.V.C. pipes and fittings including watering, curing, cost & conveyance of all materials to worksite, payment of royality, taxes etc. all complete as per direction of Engineer-in-charge. Ground Floor
First Floor
Second Floor
Supplying all materials , labour, T&P and cutting holes in RCC floors and roofs upto 19cm thick for passing P.V.C pipes and G.I fittings etc. , and repairing the holes after insertion of pipe etc. with cement concrete (1:2:4) including finishing complete so as to make it leak-proof as per P.H. specification and direction of Engineer-in-charge Ground Floor
First Floor
Second Floor
Supplying all materials, labour, T&P and cutting grooves in pucca floors and walls for taking G.I./P.V.C. pipes and making good the damages including watering , curing , cost & conveyance of all materials to worksite, payment of royality, taxes etc all complete as per direction of the Engineer-in-charge. Ground Floor
First Floor
Second Floor
Supplying all materials, labour, T&P and fitting and fixing U-PVC SWR soil waste ventilating pipes and fittings of the following outside diameter conforming to ISI No 13592/1992 to walls with nails, bobbins and wooden plugs or laying in trenches including jointing with supply of approved rubber lubricant by non-heat application method/as per manufacturer's specification, testing, earthwork in excavation in all kinds of soil and refilling of trenches , cost & conveyance of all materials to worksite, payment of taxes etc. all complete as per P.H specification and direction of the Engineer-in-charge. 110mm U-PVC SWR Pipe (Make:Astral/Ashirvad)
110mm U-PVC ‘P’ Trap (Make:Astral/Ashirvad)
110mm U-PVC door bend (Make:Astral/Ashirvad)
110mm U-PVC Plain bend (Make:Astral/Ashirvad)
110mm U-PVC offset without ear (Make:Astral/Ashirvad)
110mm U-PVC Cowl (Make:Astral/Ashirvad)
110mm U-PVC S/Jn door (Make:Astral/Ashirvad)
110mm U-PVC Plain tee (Make:Astral/Ashirvad)
110mm U-PVC D/Jn door (Make:Astral/Ashirvad)
110mm U-PVC Door tee (Make:Astral/Ashirvad)
110mm U-PVC Socket (Make:Astral/Ashirvad)
Supplying all materials, labour, T&P and fixing vitreous china water closet, squatting pan (Indian type W.C pan/Orissa pattern squatting pan) duly embedded in cement concrete (1:5:10) using 4cm size hard granite metal including fixing a pair of vitreous china 250mm x 130mm x30mm footrest, fixing 100mm dia HCI 'p' or 's' trap (with/without 50mm dia horn) for water colset squatting pan including jointing the trap with pan in cement mortar (1:1) cutting the floor and mending good the damages , cost & conveyance of all materials to worksite, payment of royality , taxes etc. all complete as per P.H specification and direction of the Engineer-in-charge. 580mm size Orissa pan (Cera/Hindware make)
Supplying all materials, labour T&P and and fixing 12.50 liters/10 liters capacity low level flushing cistern with a pair of cast iron or M.S. brackets complete with fittings such as siphonic arrangements 15mm nominal size brass/pvc ball valve with polythene float CP brass handle,unions and couplings for connection with inlet, outlet and overflow pipes, 32mm dia CP long flush bend, 15mm dia pvc inlet connection pipe including cutting holes and making good the same and connecting the flush bend with cistern and closet and connceting the inlet pipe with suupply main , cost & conveyance of all materials to worksite, payment of taxes etc. all complete as per P.H specification and direction of the Engineer-in-charge 10 ltr. Capacity pvc L.L. cistern with 32mm. Dia CP long flush bend ( Slimline-white-(Cera/Hindware make)
Supplying all materials, labour, T&P and fixing the following vitreous china Wash Down Water Closet(European type W.C. pan)with integral 'p' or 's' trap to the floor with wooden plug and chromium plated pedestal screws including jointing the trap with soil pipe in cement mortar (1:1) fixing plastic seat and cover for wash down water closet with chromium plated brass hinges and rubber buffers including polishing , cost & conveyance of all materials to worksite, payment of royality, taxes etc. all complete as per P.H specification and direction of the Engineer-in-charge One piece commod (Hindware) ELEMENT Cat No.92084. (Cera/Hindware make)
European water closet with 'p' trap plain (Cera/Hindware make)
Supplying all materials, labour T&P and fixing wash basins with hole for pillar taps with cast iron or M.S.brackets painted white including cutting holes in walls and making good the damages with supply of wooden plugs, screws and cement etc, fixing pedestal for wash basin recessed at the back for the reception of pipes and fittings, fixing PVC waste pipe of 32mm nominal diameter for wash basin including brass check nut complete, fixing pillar taps capstan head screw down high pressure lettered 'Hot' and 'Cold' with long screws, shanks and back nuts of 15mm dia nominal bore, fixing 15mm dia PVC inlet connection pipe and making connection with pillar cocks and supply mains for wash basin, fixing 32mm dia CP brass waste, cost & conveyance of all materials to worksite, payment of taxes etc. all complete as perP.H specification and direction of the Engineer-in-charge Halfpedestal basin(560x450)Hindware No.91049+91115 (Cera/Hindware make)
Supplying all materials, labour, T&P for fitting & fixing plain edge kitchen/wall sink of all standard sizes with a pair of bracket, C.P. waste, trap & P.V.C. waste pipe & painting brackets including supply of cement concrete & mortar etc. all complete. 24” x 18” x 10” sink (Cera/Nirali make)
Supplying all materials, labour, T&P and fixing standard sized CP towel rail complete with CP brass brackets fixed to wooden plugs with CP screws as per specification and direction of the Engineer in charge 25mmx600mm long CP towel rail (Cera/Jaquar make)
Towel ring (Cera/Jaquar make)
Supplying all materials, labour, T&P and fixing standard sized glass-shelf with CP brass brackets and guard rail complete fixed to wooden plugs with CP screws as per specification and direction of Engineer in charge. 600mmx125mm plate glass shelf with CP/NP guard rails. (Cera/Jaquar make)
Supplying all materials, labour, T&P and fixing mirror of superior glass mounted on 6mm.thick A.C. sheet or ply wood sheet and fixed to wooden plugs with CP screws and washers complete as per specification and direction of Engineer in charge. (Cera/Jaquar make) 600mmx450mm size B.E mirror (swivelled type)
Supplying all materials, labour, T&P and fixing CP soap holder complete with CP brass brackets fixed to wooden plugs with CP screws as per specification and direction of the Engineer in charge CP soap holder (Cera/Jaquar make)
Supplying all materials labor T&P & Fitting & fixing CP shower with rim with supply of red lead and yarn nail complete as per direction of Engineer in charge. ½” x 5” CP Shower (Cera/Jaquar make)
Supplying all materials , labour, T&P and cutting holes through existing brick or laterite masonry wall for taking U-PVC pipes and fittings including making good the damages etc. all complete as per P.H. specification and direction of Engineer-in-charge
Supplying all materials , labour, T&P and cutting of RCC chajja for taking HCI or U-PVC pipe and fittings including making good the damages etc. all complete as per P.H. specification and direction of Engineer-in-charge
Supplying all materials ,labour ,T&P and constructing Inspection Chamber of inside size 760mmx760mmx460mm with cement concrete (1:3:6) using 40mm size crusher broken hard black granite metal on bed , KB brick work in cement mortar (1:6) in foundation and plinth, moulding and shaping the channel inside and benching with cement concrete (1:2:4) using 12mm size crusher broken hard black granite chips, 12mm thick cement plaster (1:3) with cement punning to inside, cement flush pointing (1:3) to outside, R.C.C cover slab (1:2:4) using 12mm size crusher broken hard black granite chips with R.C.C man hole cover, earth work in excavation in all kinds of soil and refilling the cavity around the chamber including watering,curing,cost of all materials, conveyance of all materials to worksite, payment of royalty,all taxes etc.all complete as per approved drawing, P.H specification and direction of Engineer-in-charge Inside size 76cmx76cmx46cm with 18” dia RCC MH cover
Supplying all materials ,labour ,T&P and constructing gully trap chamber of inside size 250mmx250mm with 8cm thick RCC precast cover slab in cement concrete (1:2:4) mix using 12mm size crusher broken HG chips, foundation concrete (1:4:8) using 40mm size crusher broken HG metal on bed and around trap, KB brick work in cement mortar (1:6) in foundation and plinth and inside 12mm thick cement plastering (1:3) finished with a floating coat of neat cement including fixing 100mmx100mm size HCI gully trap, 150mmX150mm size CI grating etc.all complete as per drawing, specification and direction of Engineer-in-charge
Supplying all materials labour T&P filling sand in lavatories well watered and rammed including lead of materials to work site.
Supplying all materials, labour, T&P and providing cement concrete ( 1:4:8 ) with 4cm size crusher broken hard granite metal including watering, curing, cost of all materials,conveyance of all materials to work site with payment of royalty, all taxes etc all complete as per P.W.D specification and direction of Engineer-in-charge
Supplying all materials, labour, T&P and providing cement concrete ( 1:2:4 ) with 12mm size crusher broken hard black granite chips including watering, curing,cost of all materials, conveyance of all materials to work site with payment of royalty, all taxes etc all complete as per P.W.D specification and direction of Engineer-in-charge Ground Floor
First Floor
Second Floor
Supplying all materials, labour, T&P and providing and fixing Vitrified tiles in floors, treads or steps and landing on 25mm thick bed of cement mortar (1:1) ( 1 cement : 1 sand ) jointed with neat cement slurry mixed with pigment to match the shades of the tiles including watering, curing,cost of all materials, conveyance of all materials to work site , payment of royalty, all taxes etc all complete as per P.W.D specification and direction of Engineer-in-charge ( ceramic floor tiles of premium grade having thickness 7mm to 8mm conforming to IS 13755 of size Kajaria/Somany/Johnson tile 60cmx60cm special printed series to be pre-approved by the Engineer-in-charge ) Somany/Johnson tile 60cmx60cm Ground Floor
First Floor
Second Floor
Supplying all materials,labour,T&P and providing 12mm thick cement plaster(1:4) on brick work including watering,curing,cost of all materials, conveyance of all materials to worksite,payment of royalty,all taxes etc.all complete as per PWD specification and direction of the Engineer-in-charge. Ground Floor
First Floor
Second Floor
Supplying all materials, labour, T&P and providing and fixing porcelain glazed tiles in dado skirting on 12mm thick cement plaster (1:3) jointed with neat cement slurry mixed with pigment to match the shades of the tiles including watering, curing,cost of all materials, conveyance of all materials to work site , payment of royalty, all taxes etc all complete as per P.W.D specification and direction of Engineer-in-charge( ceramic wall tiles of premium grade having thickness 6.5mm to 6.7mm conforming to IS 13753 of size Kajaria/Somany/Johnson tile 60cmx30cm special plain / printed series to be pre-approved by the Engineer-in-charge ) Somany/Johnson tile 60cmx30cm Ground Floor
First Floor
Second Floor
Factory made single leaf Solid WPC (Wood polymer) composite door shutter of 25mm thickcompacted with wood grain finish structural foam panel of 29mm thickness and a density of 650kg/cu.mtr shall be used as core material for fitting the metal fittings such as tower bolts, aldrops, handles etc shall be provided. A structural adhesive compatible with (EPS) foam shall be used for bending the core material, The material and process for manufacturing the door shutters shall conform to RV-TIFAC composites Design Centre's standards and specifications and the door shutters Conforming to relevant I.S.specification. The finish of door shutter will be plain colour white/ Ivory/ Beige/ Light grey/ Mahogany/ Teak wood or any other colour using high quality pigments. Three heavy whight mild steel butt hinges type-I(ISI marked) size 100mm are to be fitted on one side of shutter. of make Century / Black Cobra / Rajshri Plastiwood, Hardware Fittings: Godrej / Dorset / Link / Dorma) or euivalant as per direction of Engineer-in-charge.
Factory made Solid WPC door frame of size 90mmx45mm fabricated .The door frame consist of four segments which are provided with plug-in-socket arrangement in-situ in the mould. The segments are plugged in and are joined together by means of screw. The WPC frame shall be provided with The material and process for manufacturing the door frames shall conform to Relavent I.S.specification. The finish of door frame will be plain colour white/ Ivory/ Beige/ Light grey/ Golden brown/Mahogany/ Teak wood/sand stone/Champagne/Pastel blue or any other colour using high quality pigments complete in all respect as per specification. of make Century/Black Cobra/Rajshri Plastiwood or euivalant as per direction of Engineer-in-charge.
Supplying all materials, labour, T&P and laying in trenches (to level or slope) unplasticized P.V.C. pipe conforming to IS 4985/2000 of the following out side dia for class- 3 (0.60mpa ) including jointing with supply of approved solvent cement by non-heat application method/as per manufacture's specification, provoding and laying in trench cement concrete (1:4:8) with 40mm size hard granite metal in the type C-1 standard bedding surrounding or encasing including concrete for bedding and curing etc all complete as per P.H. specification and direction of the Engineer in charge 100mm dia P.V.C. pipe
150mm dia P.V.C. pipe
Supplying all materials labor T&P and constructing MH chamber of sizes earth work in excavation in all kinds of soil CC(1:1:8) with black granite chips size 46mm brick work with K.B. brick having crossing strength not less than 75 Kg /CM2 to 90 Kg/CM2s in CM(1:6)12mm C.P(1:8) inside MH chamber over benching with cement slush pointing (1:3)outside the MH chamber providing painting MS or CI step iron RCC(roof of slab with CC(1:2:4)with black granite chips size 12mm bending binding tying the grills placing of the reinforcement providing RCC color of required size refilling the cavity around the MH chamber with excavated earth including channeling the bed of MH etc all complete as per PH specification. MH size 0.91m x 0.91 m with 0.45 m (18” dia RCC Cover )
Supplying all materials labour T&P and constructing 1.40m dia x 2.00 m deep soak way pit with dry brick having crossing strength not less than 75Kg/CM2 to 99Kg/CM2 in CM(1:6) for the remaining 0.4572mm height of wall at top CC(1:3)inside and outside inside fill with dry brick khoa size 38mm ,CM thick RCC perforated slab to a height of 1.9012m from bottom covered by means of 50mmthick RCC wall cover in pieces filled with iron plugs including earth work in excavation refilling of cavity around the pit and painting the iron works complete as per PHD design and specification including carriage of all materials to site.
2 nos 50 users RCC septic tank Earth work in excavation of foundation in all kinds of soil within 50m initial lead and 1.5m initial lift including rough dressing & breaking clods to maximum 5cm to 7cm and laying in layers not exceeding 0.30m in depth and as per direction of the Engineer-in-Charge.
Extra lifts of 1.50 mtr or part thereof over the initial lift of 1.5 mtr in all kinds of embankments and road works and ordinary earthwork in general.
Supplying all materials, labour, T&P and providing shoring and shuttering foundation trenches, pits etc with close wooden planks or sheets shuttering etc all complete as per direction of the Engineer in charge.
Supplying all materials, labour, T&P and filling in foundation and plinth with sand well watered and rammed including conveyance of all materials to worksite, payment of royalty, taxes etc.all complete as per direction of the Engineer in charge.
Supplying all materials, labour, T&P and providing cement concrete (1:3:6) with 4cm size hard granite metal including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge
Supplying all materials, labour, T&P and providing 6mm thick cement plaster (1:4) on RCC work including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge
Supplying all materials, labour, T&P and providing cement punning including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge
Supplying all materials, labour, T&P and providing rigid and smooth centering and shuttering for R.C.C works including false work and dismantling them after casting including conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge
R.C.C beams,columns,girder and bressmer etc.
Supplying all materials, labour, T&P and providing M.S reinforcement for R.C.C work including cutting, bending, binding, and tying the grills and placing in position including cost of binding wire 18 to 20 gauge, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge
Supplying all materials, labour, T&P and providing cement concrete (1:1.5:3) with 12mm size hard broken granite chips for R.C.C works including hoisting, laying, watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge
Supplying all materials, labour, T&P and providing cement concrete (1:2:4) with 12mm size hard broken granite chips including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge
Supplying all materials, labour, T&P and providing 12mm thick cement plaster (1:4) on brickwork including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge
Supplying all materials, labour, T&P and providing brick work with K.B bricks having crushing strength not less than 75kg/cm² with dimensional tolerance ± 8 percent in cement mortar (1:4) including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge
Supplying all materials, labour, T&P and making MS step iron in 20mm diameter MS steel bars and fixing into walls of man hole/septic tank duly embedded in cement concrete (1:3:6) complete as per specification and direction of the Engineer in charge.
Filling in foundation and plinth with excavated materials, moorum including watering and ramming as directed by the Engineer in charge
Construction of 20000 Liters RCC Under ground Reserver of Inside size- 4.00 X 3.00 X2.00m Earth work in All kinds of soil and gravels mixed with stone and boulder not exceeding 0.014 Cum in volume within 50m initiallead and 1.5 m initial lift including rough dressing and breaking clods to maximum 5cm to 7cm and laying in layers not exceeding 0.30m in depth and as per specification approved by the Department.
-do- with Ist additional depth of 1.50 m over the initial lead and lift
Supplying all materials, labour, T&P and filling in foundation and plinth with sand well watered and rammed including conveyance of all materials to worksite, payment of royalty, taxes etc.all complete as per direction of the Engineer in charge.
Supplying all materials, labour, T&P and providing cement concrete (1:3:6) with 4cm size hard granite metal including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge
Supplying all materials, labour,T&P and providing cement concrete (1:1.5:3) for RCC work using 12mm HG chips including hoisting,laying,curring and conveyance of all materials to site etc complete.
Supplying all materials, labour, T&P and providing M.S.Reinforcement for RCC work including cutting, banding, binding, straightening and trying the grills and placing in position including cost of binding wire 18 to 20 gage.
Supplying all materials, labour, T&P and providing rigid and smooth centering and shuttering for RCC work including false work and dismantling then after casting including cost of materials complete in ground floor. RCC floor roof, chajja etc
RCC Beam, Column, wall etc
RCC Plinth bend/ Raft Base slab
Supplying all materials, labour,T&P and providing 6mm thick cement plasster (1:4) over CC work including watering curring and conveyance of all materials to site.
Supplying all materials, labour, T&P and providing cement punning including watering, curring and conveyance of all materials to site. Quantity same as item No-4
Providing fitting and fixing CI/MS step iron including fixing to wall etc. complete
RAIN WATER HARVESTING SYSTEM(PIT)(2 nos) Earth work in hard soil or gravelly soil within 50m initial lead and 1.5m initial lift including rough dressing & breaking clods to maximum 5cm to 7cm and laying in layers not exceeding 0.3m in depth and as per direction of the Engineer-in-Charge.
Supplying all materials, labour, T&P and providing cement concrete (1:4:8) with 4cm size hard granite metal including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge
Supplying all materials, labour, T&P and providing brick work with Fly ash bricks having crushing strength not less than 75kg/cm² with dimensional tolerance ± 8 percent in cement mortar (1:6) including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge
Supplying all materials, labour, T&P and providing 12mm thick cement plaster (1:4) on brickwork with cement punning and bitumen painting over top of wall including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge
Supplying all materials, labour, T&P and providing cement punning including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge
Supplying all materials, labour, T&P and providing rigid and smooth centering and shuttering for R.C.C works including false work and dismantling them after casting including conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge R.C.C floor and roof slabs, landings, balconies, projecting sunshades and
Supplying all materials, labour, T&P and providing M.S reinforcement for R.C.C work including cutting, bending, binding, and tying the grills and placing in position including cost of binding wire 18 to 20 gauge, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge In ground floor
Supplying all materials, labour, T&P and providing cement concrete (1:1½:3)with 12mm size hard broken granite chips including hoisting, laying, watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge In ground floorSlab
providing and filling filter media 40mm Boulder-
20mm washed gravel--
Course sand-
Providing fitting & fixing M.S.grill cover over the harvesty pindi
Sinking of tube well(200) for PIT Labour for drilling a perfectly vertical bore hole of specified dia for a specified depth below ground level through consolidated and unconsolidated rock with down the hole hammer drilling rig or combination rig as required to suit the site condition as per the direction of the Engineer in charge including use of own rig with its accessories, tools and plant and consumables etc for lowering of 200mm/150mm dia G.I/P.V.C/M.S casing pipes for housing fitted with socket and with or without well screen as per the necessity for soft, medium, hard and boulder formation (G.I/ P.V.C/ M.S casing pipes if required to prevent collapse of overburden is to be provided by the contractor including lowering and withdrawing after completion of the tube well), 200mm dia to 400mm dia in overburden portion including packing of gravel supplied by the contractor for 400mm dia bore only Drilling of 200mm dia bore 00 mtr to 25mtr
Lowering the following size of G.I/P.V.C/M.S housing pipes with or without slotted pipes as per the necessity from ground level up to 45.00m depth and fitted and fixed up in perfectly vertical position including cutting and threading of pipes and slotted pipes and supplying and fixing all jointing materials, tools and plant etc all complete and keeping the top of casing pipe threaded including plugging tube wells to prevent entry of foreign materials. 200mm dia PVC pipe
cost of 200mm pvc pipe
Cutting slot in casing pipe for recharge of rain water
labour for packing gravel outside the tube well
Cost of washed gravel
Construction of 1 no production wells including scientific source finding through consolidated and unconsolidated rock with down the hammer drilling rig or combination rig with PVC pipe and installation of submersible pump set with all acessories Labour for drilling a perfectly vertical bore hole of specified dia for a specified depth below ground level through consolidated and unconsolidated rock with down the hole hammer drilling rig or combination rig as required to suit the site condition as per the direction of the Engineer in charge including use of own rig with its accessories, tools and plant and consumables etc for lowering of 200mm/150mm dia G.I/P.V.C/M.S casing pipes for housing fitted with socket and with or without well screen as per the necessity for soft, medium, hard and boulder formation (G.I/ P.V.C/ M.S casing pipes if required to prevent collapse of overburden is to be provided by the contractor including lowering and withdrawing after completion of the tube well), 200mm dia to 400mm dia in overburden portion including packing of gravel supplied by the contractor for 400mm dia bore only Drilling of 200mm dia bore 00 mtr to 30mtr
30 mtr to 45mtr
Drilling of 150mm dia bore 45 mtr to 215.00mtr
Lowering the following size of G.I/P.V.C/M.S housing pipes with or without slotted pipes as per the necessity from ground level up to 45.00m depth and fitted and fixed up in perfectly vertical position including cutting and threading of pipes and slotted pipes and supplying and fixing all jointing materials, tools and plant etc all complete and keeping the top of casing pipe threaded including plugging tube wells to prevent entry of foreign materials. Lowering of 200mm dia P.V.C casing pipes 00 mtr to 30 mtrs
30 mtr to 60mtr
Supplying polyvinyl chloride pipes as per ASTM-D-1785-89 having threads in accordance with DIN 2999 part-1/DIN-42225 part-II specification length of pipe (laying length) will be 3 mtrs. The pipes shall be supplied with both external and threaded with free socket. The pipe having external thread at one end i.e female and or belled end. The female end having internal thread is to be belled in order to accept the male end while jointing pipes with a bore threading shall be provided with a greave at the roof of the male thread accomodate flexible PVC/Rubber 'O' ring to make the joint water tight colour of the pipe shall be blue. The name of the manufacture along with batch No class of pipe shall be stranded legibly of each pipe length. 200mm dia PVC (sch-80) pipe
Supplying all materials, labour, T&P and providing and providing sanitary sealing by cement concrete grouting of annular space around GI/PVC/MS housing pipe upto 5m below ground level (as per drawing) to plug the bore hole excluding cost of cement all complete as per direction of the Engineer in charge. Minimum one metre of casing pipe to be inserted in the bore into the rock at the bottom to ensure sanitary sealing (excluding cost of cement which will be supplied directly by the department)
Cleaning and developing the tube well with supply of compressor worked till clear and adequate discharge is obtained from the tube well including supply and use of all necessary equipment and labour as per direction of the Engineer in charge By DTH Rig
Supplying all materials, labour, T&P and providing, fitting and fixing submersible pump with squirrel cage induction type submersible type submersible electric motor to run on 3 phase/1 phase line voltage ranging from 320 volt to 450 volt conforming to IS: 8034/89 with following specifications with suitable control panel, jointing with GI/PVC/HDPE pipes, electrification, testing, commissioning, trial running, conveyance of all materials to worksite, payment of taxes etc all complete as per specification and direction of the Engineer in charge (Texmo/Crompton Greaves/Kirloskar make) 1 H.P. Single phase/ three phase 3 stage head renge of 20 to 35 mtr with discharge capasity 145 to 110 L.P.M With outlet dia 25 mm (keeping 100% standby)
DOL Control panel
40mm dia steel short piece
Well cap
50mm size CI bracket
2.50sqmm flat cable
20mm dia rigid UPVC pipes
Steel rope with cover
Labour charges for lowering including transportation
Supplying all materials, labour, T&P and providing and fixing to wall or ceiling and floor HDPE pipes and pipe fittings conforming to IS: 4984/2000 (10kgf/sqcm) of the following nominal bore with clamps and jointing by Fusion welding method including testing, making good the wall, ceiling and floor all complete as per specification and direction of the Engineer in charge 32mm HDPE pipes (Finolex/Supreme make)
Subhead- I (Internal Electrification) Recessed wirring to light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor (Make-Havells/Polycab/Finolex/RR Kable ) of ISI marked with 20 mm dia PVC heavy class FRLS non metallic conduit(Make-AKG/Polycab/precision/norpack/sudhakar) with 6A modular type switch(Make-Legrand(Myrius),Schneider(Zencelo),Panasonic(Vision) ) ISI marked , and ceiling rose ISI marked of modular type G.I box with cover , of suitable size, modular box with 1.5 sq. Mm FRLS PVC insulated single core multistandard copper conductor as earth wire including all accessories and connection .Raw power supply switch board shall be separate from emergency power supply switchboard as per direction of Engineer -in -Charge.Each light point should have provision for ceiling rose & angle holder point. Group-A: L.P= F.P= C.B.P=
Group-B: L.P= F.P= C.B.P=
Group-C: L.P= F.P= C.B.P=
Supplying and fixing of (for internal wiring) cover plates, moulded frame,Two-way 6A switches, with all accesories and connection as per direction of Engineer in Charge. (modular type) (Make-Legrand(Myrius),Schneider(Zencelo),Panasonic(Vision)
Supply and fixing CALL bell (Ding dong type) /Buzzer on the existing switch box/cover. as required as per direction of Engg.-in-Charge. (Make-Legrand(Myrius),Schneider(Zencelo),Panasonic(Vision)
S/F of 5 step type Modular electronic Fan Regulator ISI Marked with all connection complete in all respect as per direction of Engineer in charge ( Make-Schneider(Zencelo)/legrand( Myrius)/Panasonic (vision)
Supplying ,fixing of 6A Plug on the same board in existing switch board with complete fitting by 01 no of 6A switch & socket (modular type)(Make-Legrand(Myrius),Schneider(Zencelo),Panasonic(Vision) & other required accessories of ISI marked as approved as per direction of Engg. -in -Charge.
Supplying and fixing including testing and commissioning of 6A modular socket outlet with 6 Amp switch including providing GI modular box with faceplate etc as required.Switch & socket: (modular type) (Make-Legrand(Myrius),Schneider(Zencelo),Panasonic(Vision) 1 nos 6 Amp 3-pin socket with 6 Amp switch.
2 nos 6 Amp 3-pin socket with 2 nos 6 Amp switch.
Supplying,fixing of 16A Plug on the separate board with complete fitting by 01 no of 6A switch & socket(modular type) (Make-Legrand(Myrius),Schneider(Zencelo),Panasonic(Vision) with suitable size modular box & cover including supplying of all required accessories of ISI marked as approved as per direction of engg-in-charge.
Supplying and installation of 25A AC starter Modular type or any other equivalent reputed make as approved coil voltage-415 Volt A.C. & O/L range of suitable range range on mod Box of suitable size including modular coveras required as per direction of Engg.-in-Charge .(Make-Legrand/Schneider/ Havells/ABB)
Receass wiring for circuit/submain wiring with the following mentioned size PVC insulated, copper conductor FRLS, single core cable (Make-Havells/Polycab/Finolex/RR Kable/KEI/Gloster) in recessed PVC FRLS conduit HEAVY duty (Make-AKG/Polycab/precision/norpack/sudhakar) of mentioned size as approved) as required as per direction of Engg.-in-Charge.. 2 nos single core 1.5 sq. mm copper wire for phase and neutral and 01 no of single core 1.5 sq. mm copper wire for earth continuty conductor in 20 mm dia non metallic FRLS heavy duty PVC conduit.(BDB to LSB/LIGHT CKT/5A PLUG/INVERTER POINT TO EACH QTR) (2X2.5+1X1.5)
2 nos single core 2.5 sq. mm copper wire for phase and neutral and 01 no of single core 1.5 sq. mm copper wire for earth continuty conductor in 20 mm dia non metallic FRLS heavy duty PVC conduit(BDB to LSB/LIGHT CKT/5A PLUG/INVERTER POINT TO EACH QTR) (2X2.5+1X1.5)
2 nos single core 4 sq. mm copper wire for phase and neutral and 01 no of single core 1.5 sq. mm copper wire for earth continuty conductor in 20 mm dia non metallic FRLS heavy duty PVC conduit . (2X4+1X1.5)
2 nos single core 6 sq. mm copper wire for phase and neutral and 01 no of single core 2.5 sq. mm copper wire for earth continuty conductor in 25 mm dia non metallic FRLS heavy duty PVC conduit .(PANEL TO BDB EACH QTR) (2X6+1X2.5)
Receass wiring for circuit/submain wiring with the following mentioned size PVC FRLS insulated, copper conductor, single core cable Make- Finolex/Anchor/Polycab/HAVELLS/RR KABLE/KEI in recessed HMS FRLS PVC conduit of mentioned size Make-AKG/BEC/Precision/Norpak/Anchor/Kinjal as required as per direction of Engg.-in-Charge. 4 nos single core 10 sq. mm copper wire for phase and neutral and 02 nos of single core 6 sq. mm copper wire for earth continuty conductorin 32 mm dia non metallic heavy duty conduit .(PANEL TO ACDB) (4X10+2X6)
SITC an fixing of recess/surface mounted 2'x2' 36 W(595mmx595mmx70mm) square shaped LED with lumen efficacy not less than 130lm/W, CRI not less than 80, CCT of 5700-6500 degree K, THD less than 10%,internal surge protection of 3 KV, complete with Non integrated isolated electronic driver (protects the output /secondary side from any disturbance on the input / primary side ensuring safe operation)and all other accessories suitable for operation on140- 270 V, 50 Hz ,L70 @50,000 burning hrs (5 years warranty) as required as per direction of Engg.-in-Charge (Make: Panasonic/LT/Havells /Philips/Wipro /Crompton/Bajaj) . The luminaire must be Replacement Warranty will be 5years.
SITC and fixing of Energy efficient Recess /Surface mounted square/round shaped LED luminaire made up of CRCA powder coated sheet steel of 25W and system lumens output not less than 3250 lumens (130 lm/ wt) with diffusers for better light transmission and pure effect with High luminous flux LEDs for better light output, CRI not less than 80, CCT of 5700-6500 degree K, THD less than 10%,internal surge protection of 3 KV, complete with Non integrated isolated electronic driver (protects the output /secondary side from any disturbance on the input / primary side ensuring safe operation)and all other accessories suitable for operation on140- 270 V, 50 Hz ,L70 @50,000 burning hrs (2 years warranty)supply .as required as per direction of Engg.-in-Charge (Make: Panasonic/LT/Havells /Philips/Wipro /Crompton/Bajaj) . The luminaire must be Replacement Warranty will be 2 years.
SITC of energy efficient LED tube light fittings with decorative alumunium LED batten along with LED tube light having power rating 20 watt and lumen output not less than 2200 lumen complete with electronic driver and all other accessories with diffuser i/c connection etc as required.The luminaire should be Replacement Warranty will be 2 years (Make: Panasonic/LT/Havells /Philips/Wipro /Crompton/Bajaj).
SITC of Energy efficient surface /recess mounted square /round shape 15 W LED luminaire of dimension of consists of white powder coated , die-cast Alluminium housing with high quality frosted diffuser for glare-free uniform lighting distribution with wattage not more than 18 watt and lumen output of 1800 lumens, , CRI not less than 80,CCT of 6000 degree K,THD less than 10%, with electronic driver, internal surge protection of 3 KV , L70 B50: 50000 hrs and all other accessories suitable for operation on 220 V to 240 V supply as required as per direction of Engg.-in-Charge. (Make: Panasonic/LT/Havells /Philips/Wipro /Crompton/Bajaj).The luminaire should be Replacement Warranty will be 2 years
SITC of Energy efficient surface /recess mounted square /round shape 12 W LED luminaire of dimension of consists of white powder coated , die-cast Alluminium housing with high quality frosted diffuser for glare-free uniform lighting distribution with wattage not more than 18 watt and lumen output of 1800 lumens, , CRI not less than 80,CCT of 6000 degree K,THD less than 10%, with electronic driver, internal surge protection of 3 KV , L70 B50: 50000 hrs and all other accessories suitable for operation on 220 V to 240 V supply as required as per direction of Engg.-in-Charge. (Make: Panasonic/LT/Havells /Philips/Wipro /Crompton/Bajaj).The luminaire should be Replacement Warranty will be 2 years
SITC of surface Mounted Led bulk head Lighter comprising of 10W LED BULK HEAD LIGHTwith non integral / integral driver, 6500K color temp having 40000 burning hrs life with minimum @ L 70, system lumen output should be minimum with efficacy > 120 lm/W. LED driver PF 0.95 & THD < 20%. The colour rendering index of LED light should be more than 70. Submission LM 80-08 Form LED Source Manufacturer & LM79-08 / IS16106 from NABL approved lab. Manufacturer mandatory i/c connection wire, testing etc. to complete the job. (Make: Panasonic/LT/Havells /Philips/Wipro /Crompton/Bajaj)
SITC of Energy efficient surface /recess mounted square /round shape 9W LED luminaire of dimension of consists of white powder coated , die-cast Alluminium housing with high quality frosted diffuser for glare-free uniform lighting distribution with wattage not more than 9 watt and lumen output of 900 lumens, , CRI not less than 80,CCT of 6000 degree K,THD less than 10%, with electronic driver, internal surge protection of 3 KV , L70 B50: 50000 hrs and all other accessories suitable for operation on 220 V to 240 V supply as required as per direction of Engg.-in-Charge. (Make: Panasonic/LT/Havells /Philips/Wipro /Crompton/Bajaj).The luminaire should be Replacement Warranty will be 2 years
SITC of Sleek LED 10 watt mirror light fitting with extruded polycarbonate housing,High optically efficient diffuser,above wash basin complete with all accessoriesetc. directly on wall, including connection with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required as per direction of Engg.-in-Charge. (Make: Panasonic/LT/Havells /Philips/Wipro /Crompton/Bajaj)The luminaire should be Replacement Warranty will be 2 years
Supplying, installation, testing and commssioning of BLDC ceiling fan with aluminium blades having wattage not more than 28W and Air delivery ≥ 215(m3/min) Make-USHA(Technix)/Crompton(Energion Groove)/Havells(Efficiencia Neo ) including wiring the down rod of standard length (upto 30 cm) with 1.5 sq mm PVC insulated, copper conductor, single core cable etc. as required as per direction of Engg.-in-Charge,Replacement Warranty will be 4 years.. . 1200 mm sweep
Supplying of Exhaust fan / fresh air fan with louvre (Make -Crompton/ Orient/ Havells/Polycab) as required. Supplying, installation, of exhaust fan of heavy duty 200 mm sweep with louvers any other equivalent reputed make star rated as approved) of exhaust fan in the existing wall, including fixing & conntection as required as per direction of Engg.-in-Charge. Replacement warranty shall be 2 years. Make-Havells/Bajaj/Usha/Crompton /Orient
Air Conditioing System Supply, Installation, Testing, Commissioning of highwall Inverter comptabilie split units (minimum 5 star) of following capacities including proper mounting arrangements and accessories, copper refregirant piping,pvc drain piping,power cable,control cable, initial charge of refrigerant, safety limit thermostat, etc complete including 5 KVA voltage stabilizers. ( Make - Voltas/Daikin/LG/Hitachi ) 1.5 TR capacity.
REFRIGRANT PIPING Supply,installation of hard/soft copper refregrant piping of size 5/8 inch and 1/4 inch for suction and liquid line with 3 corex4 sqmm FRLS Copper control cable alongwith 25 mm weather proof closed cell nitrile insulation ,complete with fitting of bends and other nesessary material to complete the job. 1 TR to 3 TR high wall split A.C
FRAME WORK Supply,installation & fabrication of MS base frame for both indoor and outdoor unit and other nesessary material to complete the job. 1 TR to 3 TR high wall split A.C
DRAIN PIPING Supply,installation & fabrication of Insulated drain water piping from indoor to nearestdrain point separate to all and other nesessary material to complete the job. 25mm nom. Dia pipe
Supply,Installation, Testing & Commissioning of of 10 Passenger lift gearless with Machine room Capacity,Elevator G+3 Floors (Shaft size should not be less than-1750mm(Left to right)x1950mm(Front to back)) (Min. Car size-1300mmx1350mm, car opening should not be less than 800mm) with ACVVVF drive/Control for constant load of 680 kg ARD 1.25 MPS,all SS materials shall be of grade SS-304 with thickness not less than 1.6mm, SS honeycomb interior ,2hr fire rated door with simplex operation without attendant car position indicators,battery operated alarm bell & emegency light,SS honeycomb finish door finished car interior, recess Granite flooring ,power operated centre opening automatic sliding SS honeycomb finish doors for car entrance & hoist way entrance etc . Machine beams,buffer support channels,facia plate including sills pit ladder metal screen in Elevator pit etc.as per specifiaction including cost of (i)Overload detection,(ii)Voice announcement,(iii) Intercom,(iv)Braille Buttons with all Civil & Electrical works required for installation of Elevator in the existing lift well and machine room,scaffolding ,floor cutting including Fireman's switch complete in all respect.The Elevator should be suitable for physically handicapped person. (MAKE:OTIS/Mitsubishi/Schindler) Serving four floors (G+1st to 2nd) & Travel 12.6 mtrs.
10KVA ONLINE UPS Supply ,installation ,testing & commissioning of 10KVA Parallel UPS SYSTEM WITH IGBT based inverter system, true online double conversion system, inbuilt isolation transformer & automatic phase sequence corrector of 3ph in put to 1 ph output,240V, with built in BMS with battery back up up to 30 minutes with MS Rack for battery Housing, DC cable 7 Mtr with SFU and links for installation (Battery required: 12V, 42AH, 20 No.s) protection for fault by OL,UV,EF,GF,OC,Ph. (Make:Numeric/ APC/ Vertiv)as per direction of Engg.-in-Charge. Warrentee period of all accessories & component & system must be 2 years & compelete test certificate must be submitted along with ups including component list & SLD.
Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required.
Supply, delivery, installation and testing of TV Antenna Wires RG6 in PVC Pipe and making good the damages caused complete as required and as per Direction of Engineer-In-Charge. Make :-Finolex/Polycab/KEI
Supplying and fixing T.V. antenna socket outlet piano type ISI marked on the existing switchboard / cover including connections etc as requird.(Make :Legrand(Myrius),Schneider(Zencelo),Panasonic(Vision)
BDBS,DB,AC DB,FLOOR PANELS,MCBS Supplying and fixing of following mentioned way, three pole/single pole and neutral, sheet steel,double door MCB distribution board, 415 volts/240 volts shall be as per IEC 61439-3,integrated door earthing system offering additional safety to the user,High quality polyurethane Gasket,the box and cover shall be fabricated to withstand IK09,the DB should be properly pre-treated with 7 tank process and duly powder coated, phosphatized with powder coated finish, on surface/recess, complete with terminal blocks,with suitable size FR PVC insulated copper conducter up to terminal blocks, tinned copper busbar, neutral busbar, earth bar, din bar. Make-LEGRAND-Ekinox3 DB/ Siemens-Betaguard/ Schneider- Acti 9 /LK -Exora-N as per direction of Engg.-in-Charge. The Distribution boards should be Replacement Warranty will be 3 years. 4 Way(8+(4x3)+(3x4)) Way TPN MCB DD 7 Segment DB Horizontal Type as per IEC 61439-3 with configuration of incomming I-8 modules,sub incommer-12 module & out going-12 modules,suitable for Flush mounting and Surface mounting with Copper Bus Bar for each phase, with neutral Bus bar, Earth Bar & Cable ties for cable management, prefitted masking sheet, IP43-IK09 with metal door Warranty on DB is 3 years
4 Way(8+12) Way TPN MCB DD DB Horizontal Type as per IEC 61439-3 suitable for Flush mounting and Surface mounting with 100A Copper Bus Bar for each phase, with neutral Bus bar, Earth Bar & Cable ties for cable management, prefitted masking sheet, IP43-IK09 with metal door Warranty on DB is 3 years
Supplying and fixing following rating RCBOs/ MCBs in the existing DB complete with connections,testing and commissioning etc. as required. Supplying and fixing 63Amps 4P 415 volts MCB Make-LEGRAND-DX3 / Siemens-Betaguard/ Schneider- Acti 9/LK in the existing MCB DB in the existing MCB DB complete with connections as per direction of Engg.-in-Charge..Warranty on MCB is 1 years.
Supplying and fixing 40 Amps , 2P, 415 volts, RCCB breaking capacity 30mA . Make-LEGRAND-DX3 / Siemens-Betaguard/ Schneider- Acti 9/LK in the existing MCB DB complete with connections, testing and commissioning etc. as required as per direction of Engg.-in-Charge. . The RCCB should be Replacement Warranty will be 1 year
Supplying and fixing 6-32 Amps rating, C series,10KA breaking capacity,SP, 240 volts, MCB . Make-LEGRAND-DX3 / Siemens-Betaguard/ Schneider- Acti 9/LK in the existing MCB DB complete with connections, testing and commissioning etc. as required as per direction of Engg.-in-Charge. .. The MCB should be Replacement Warranty will be 1 years..
Supplying and fixing of following sizes of heavy gauge PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. Make-AKG/BEC/Precision/Anchor 20 mm
Supply and laying of 25/32mm U PVC trunking system and acessories.(Make:Legrand/MK(honeywell)
Providing and fixing extra down rod of 20 cm length G.I. pipe 20 mm dia heavy gauge including painting etc as required . ( more than 5 cm lenght shall be rounded to the nearest 10 cm and 5 cm or less shall be ignored.
FIRE EXTINGUISHER SYSTEM Supply,Installation,Testing and Commisioning of ISI marked (IS:2878) Fire Extinguisher ,Carbon di-oxide type capacity 4.5kg with all accessories (Ever safe/Fire shield/Ceasefire/Safex)
Supply,Installation,Testing and Commisioning of ISI marked (IS:2878) Fire Extinguisher ,ABC type capacity 6kg with all accessories (Ever safe/Fire shield/Ceasefire/Safex)
Fire buckets (FILLED WITH SAND) round bottom type enamel painted, white inside & Red out side and Letter "FIRE" in black out side and handle with mounting bracket.
First Aid Box.
Shock Treatment Chart (Odia / Hindi & English).
8 mm thick Rubber Mat.
Danger Board.
LAN,DATA & TELEPHONE LAN & TELEPHONE SITC of 24 Port Layer 2 PoE+ Switch having 24 x 10/100/1000 Mbps Ethernet PoE+ ports with 4 x 1/10Gig SFP+ ports ,1 x RJ45 port console port ,Switching Capacity 128 Gbps , Throughput 96 Mpps ,MAC Address 16k , Switch should support IEEE 802.3af (15.4W) & IEEE 802.3at (30W). Total PoE power: 370W or above , Switch should support DHCP server/relay/client, DHCP snooping/option82 , Switch should support Console, Telnet, SSH v1/2, HTTP, HTTPS, SNMP v1/v2/v3, RMON , TFTP, FTP, SFTP, NTP, ZTP, SPAN, RSPAN,Switch should support support ICMPv6, DHCPv6, ACLv6 ,IPV6 Telnet ,Temperature 0°C -50°C ,Power Supply AC: 100-240V. Make: Digisol, Cisco, HP
SITC of Cat 6, 24-port loaded, 1U Modular Jack Panel Should accommodate Cat6 with Rear Cable Management and Front removable Tooless Information outlet. Should have easy clip management with labels and clear label covers, Made with of Dicast Aluminium Alloy Material and Non Corrosive with Cat6 toolless RJ45 x 24 ports with color code front panel with patch cord locking. Make: Systimax, Legrand, Panduit
SITC of Cat6 I/O with Single Face plate: The Outlet shall meet or exceed requirement as per ANSI/TIA 568C.2,ISO/IEC 11801, & EN50173. The information outlet NEXT, PSNEXT, FEXT, ELFEXT, PSELFEXT and return loss should be verified for CAT6 @ 250Mhz & CAT6A @ 500Mhz. The information outlet connector shall be of gold/nickel, thickness of gold > 0.8 μm. The connectors shall be compatible as per IEEE 802.3af standard for POE application. The PVC material of Face plate should complie ABS /UL94-V-O certified. Make: Systimax, Legrand, Panduit
SITC of Cat6 I/O with Dual Face plate: The Outlet shall meet or exceed requirement as per ANSI/TIA 568C.2,ISO/IEC 11801, & EN50173. The information outlet NEXT, PSNEXT, FEXT, ELFEXT, PSELFEXT and return loss should be verified for CAT6 @ 250Mhz & CAT6A @ 500Mhz. The information outlet connector shall be of gold/nickel, thickness of gold > 0.8 μm. The connectors shall be compatible as per IEEE 802.3af standard for POE application. The PVC material of Face plate should complie ABS /UL94-V-O certified. Make: Systimax, Legrand, Panduit
SITC of Cat6 UTP 24 AWG Patch Cord Patch cord: 6 UTP Patch Cords are Factory Tested for Better Quality and Suitable for the High Speed Data Transmission. Complies to the Standard ANSI/TIA/EIA-568-C.2 Standard. Supports Data Networks Speeds Up to 10/100-Base-T and 1000-Base-T. Available In LSZH Jacket- Reduced Toxic Gasses Emitted During Combustion , RJ45, 8P8C, 2 FORK 50μ’’ Gold Plated Contacts , 100% Factory Tested , Transparent Boot Cable Assemblies. Make: Systimax, Legrand, Panduit(1 mtr length)
SITC of 4 pair Cat6 23 awg U/UTP LSZH Cable in the existing surface/ recessed steel/ PVC conduit as required: The 4 pair Unshielded Twisted Pair cable shall be UL Listed,exceeds the requirements of ANSI/TIA-568-C.2 and ISO/IEC 11801 Class E , 4 twisted pairs separated by internal PE Cross Separator. Full separator. Half shall not be accepted. Rip Cord is must,Insertion Loss of 32.8 db/100m at 250 MHz ,Cable should support operating temperature from -20° to +70°C Cable support Conductor Resistance ≤ 9.38 Ω/100m Max., Cable support Delay Skew: < 45 ns/100m, Operating Voltage: 72V , Impedance: 100 ± 15 Ω @100 MHz. and Propagation Delay @250 MHz : 536 ns/100m, ETL Verified 4 connector channel performance up to 700 MHz , RoHS Compliant. Make: Systimax, Legrand, Panduit
SITC of Rack mount Draw Type Loaded 6 port LIU available in Standard 19” ,Dimensions (mm) : 430 X 220 X 1U , Cold Rolled Steel as Raw Material , Consist of Top Cover and Bottom Panel , Easy to Assemble and Dissemble , Three Types of Input Holes Cable Entry Through Water Proof Cable Clamp , 12 Duplex SC or LC Adapter Interface , Splice 24 Fibers at Most with 1 Tray ,Adaptor, SM, Duplex SC, PC Type ,Pigtail, Support the TIA/EIA Telecommunication Wiring Standards. Compact Design , Telcordia GR-326-Core . Make: Systimax, Legrand, Panduit
SITC of OFC Patch Cor, SM (OS2), Duplex LC-SC, LC-LC PC Type, 3M, LSZH Fiber Optic Single Mode OS2 Patch Cords are offered in LSZH Jackets with Corning Fiber,Insertion Loss : <= 0.2 db, Max 0.3db/MTRJ: Max 0.5db Return Loss : PC>= 45db, UPC>=50db, APC>=60db. Make: Systimax, Legrand, Panduit
SITC of 1G-LX/LH SFP transceiver module,SMF, 1310nm, 9/125 um Single mode Fiber Type up to 10 KM. Make: Cisco, Digisol, Netgear
SITC of 9U/500D Wall Mount Rack with Accessories: The rack size should be 600W x 500D, Front frame integrated with top, bottom, front and two side panels for better rigidity and strength, Front Glass Door with Lock loaded, Compliance with standards shall be UL 2416., DIN 41494, IEC EN 60529, IEC EN 62262 , IEC EN 60068-2-11 , ISO 9001:2008 including Power Distribution Unit (06/16 Amp Indian-Standard - 06 Socket - Single Pole / Screw Mountable / 16 Amp MCB / Alternating Current - 16 Amp 3 Pin Plug with Power Cable 2.5 sq.mm 3 meter Lengt), 1 cooling Fan(230V AC - 90 CFM, dB 42), 2nos 1U Metal Cable manager with Plastic cable loops and H/W screw. Make:Valrack, Rittal, Legrand
IP PBX Supply and installation of IP Based PoE Phone, 2 SIP accounts, 2 line keys, 3-way conferencing, 3 XML programmable context-sensitive soft keys, Dual-switched 10/100 mbps ports, integrated PoE, HD audio on speakerphone and handset. Make: Grandstream, NEC, Mitel
CCTV SITC of 32Ch 4K Network Video Recorder 8 sata , Up to 12 Megapixels resolution recording,Remonte Connection 128, SSynchronous Playback16CH, RAID0, RAID1, RAID5, RAID10. Supported, RS-232, RS-485, Keyboard, Front panel: 2 × USB 2.0, Rear panel: 1 × USB 3.0,ALARM IN/OUT-16/4, Incoming bandwidth-320Mbps or 200Mbps (when RAID is enabled),2HDMI/2VGA.STQC compliant product in complete as per the direction of Engineer-in-charge Make-Honeywell(Series 20)/Pelco/ Axis /Bosch/Equivalent
Supply, Installation,Testing & Commisioning of Surveliance 10 TB HDDMake:- WD/Segate/Toshiba
Supply, Installation, Testing & Commissioning of 5MP IP Network TDN Low-Light IR Fixed Lens Dome/Bullet Camera, 1/2.8" CMOS or better, 5MP (2592 x 1944) @ 25fps or better, triple stream at various resolution & Frame Rates, Min. Illumination required 0.007 lux (color), 0 Lux IR On, 2 IR LEDs, Smart IR with upto 50m IR distance, Auto ICR (Infrared Cut Filter) 120dB True WDR, S/N Ratio 50db, Shutter Speed 1/8 - 1/30,000; Adavance Video Compression technology such as H.265, H.264 & MJPEG , Fixed Lens 2.8mm, Field of View FoV H:90°, V:62°, BLC, HLC, WDR, 3DNR, White Balance - Auto/Manual, Minimum Edge Intelligence Video Analytics : Video Motion Detection, Tampering, Loitering, Intrusion, & People Counting, 4 Privacy Mask, 8 Region Of Intreset, Defog, HTTPS, IP Filter, TLS1.2, AES-128/256, SSH/Telnet closed, Stream Encryption, 2-Way Audio Full Duplex Line IN/Out, 256GB SD card support, Alarm: 1In/1out, PoE (802.3 af) and 12V DC, Max 5W, IP 66/67 & IK10 with Die Cast Aluminium Housing, Having Operating temp range : –40°C to 60° C. Certifications: ONVIF Profile S/G/T compliant,, CE (EN 50130-4), FCC Part 15, EN 55032 & RoHS (EN63000)/NDA/STQC compliant. Make-Honeywell(Series 20), Pelco, Axis
Supply, Installation, Testing & Commissioning of 5MP IP Network TDN Low-Light IR motorized Lens Bullet Camera, 1/2.8" CMOS or better, 5MP (2592 x 1944) @ 25fps or better, triple stream at various resolution & Frame Rates, Min. Illumination required 0.007 lux (color), 0 Lux IR On, 4 IR LEDs Smart IR with upto 50m IR distance, Auto ICR (Infrared Cut Filter) 120dB True WDR, S/N Ratio 50db, Shutter Speed 1/8 - 1/30,000; Adavance Video Compression technology such as H.265 & H.264 High Profile & MJPEG , Triple stream, Fixed Lens 2.8mm, BLC, HLC, 3DNR White Balance, Minimum Edge Intelligence Video Analytics : Video Motion Detection, Tampering, Loitering, Intrusion, & People Counting, 4 Privacy Mask, 8 Region Of Intreset, TLS1.2, AES-128/256, SSH/Telnet closed, Stream Encryption, Dual channel Audio, Alarm: 1In/ 1out, 256GB SD card support, PoE (802.3 af) and 12V DC, Max 6W, IP 66, IK 10 vandal proof with Die Cast Aluminium Housing, Having Operating temp range : –40°C to 60° C. Certifications: ONVIF Profile S/G/T compliant, CE (EN 50130-4), FCC Part 15, EN 55032 & RoHS (EN63000)/NDA compliant. Make-Honeywell(Series 20), Pelco, Axis
SITC of 6U/500D Wall Mount Rack with Accessories: The rack size should be 600W x 500D, Front frame integrated with top, bottom, front and two side panels for better rigidity and strength, Front Glass Door with Lock loaded, Compliance with standards shall be UL 2416., DIN 41494, IEC EN 60529, IEC EN 62262 , IEC EN 60068-2-11 , ISO 9001:2008 including Power Distribution Unit (06/16 Amp Indian-Standard - 06 Socket - Single Pole / Screw Mountable / 16 Amp MCB / Alternating Current - 16 Amp 3 Pin Plug with Power Cable 2.5 sq.mm 3 meter Lengt), 1 cooling Fan(230V AC - 90 CFM, dB 42), 2nos 1U Metal Cable manager with Plastic cable loops and H/W screw. Make:Valrack / Rittal / APW
SITC of 24 Port Layer 2 PoE+ Switch having 24 x 10/100/1000 Mbps Ethernet PoE+ ports with 4 x 1/10Gig SFP+ ports ,1 x RJ45 port console port ,Switching Capacity 128 Gbps , Throughput 96 Mpps ,MAC Address 16k , Switch should support IEEE 802.3af (15.4W) & IEEE 802.3at (30W). Total PoE power: 370W or above , Switch should support DHCP server/relay/client, DHCP snooping/option82 , Switch should support Console, Telnet, SSH v1/2, HTTP, HTTPS, SNMP v1/v2/v3, RMON , TFTP, FTP, SFTP, NTP, ZTP, SPAN, RSPAN,Switch should support support ICMPv6, DHCPv6, ACLv6 ,IPV6 Telnet ,Temperature 0°C -50°C ,Power Supply AC: 100-240V. Make: Digisol, Cisco, HP
SITC of Cat 6, 24-port loaded, 1U Modular Jack Panel Should accommodate Cat6 with Rear Cable Management and Front removable Tooless Information outlet. Should have easy clip management with labels and clear label covers, Made with of Dicast Aluminium Alloy Material and Non Corrosive with Cat6 toolless RJ45 x 24 ports with color code front panel with patch cord locking. Make: Systimax, Legrand, Panduit
SITC of HDMI 2.0 cable, 5m. MAKE: FALCON/HONEYWELL/ LIBERTY
SITC of Cat6 UTP 24 AWG Patch Cord Patch cord: 6 UTP Patch Cords are Factory Tested for Better Quality and Suitable for the High Speed Data Transmission. Complies to the Standard ANSI/TIA/EIA-568-C.2 Standard. Supports Data Networks Speeds Up to 10/100-Base-T and 1000-Base-T. Available In LSZH Jacket- Reduced Toxic Gasses Emitted During Combustion , RJ45, 8P8C, 2 FORK 50μ’’ Gold Plated Contacts , 100% Factory Tested , Transparent Boot Cable Assemblies. Make: Systimax, Legrand, Panduit(1 mtr length)
SITC of 55" UHD IPS Commercial Digital Display for Small Size Discussion & Chambers: Brightness (440 nits or higher), Dynamic Contrast Ratio (Dynamic MCI (Hz)):1000000:1), 1000000:1, Static (Panel) Contrast Ratio-1200:1, Response Time (G to G)-8 ms, Refresh Rate.-60 Hz, Life span (hrs)-30,000, Speaker (Sound Output):10W + 10W, Speaker System: 2.0 ch, DVB-T2/C Broadcasting System, Commercial Smart UX, webOS version (webOS 6.0), BIS Certification with 3 years onsite warrenty. (For CCTV and individual suites) Make: LG/Samsung/Sony
SITC of 4 pair Cat6 23 awg U/UTP LSZH Cable in the existing surface/ recessed steel/ PVC conduit as required: The 4 pair Unshielded Twisted Pair cable shall be UL Listed,exceeds the requirements of ANSI/TIA-568-C.2 and ISO/IEC 11801 Class E , 4 twisted pairs separated by internal PE Cross Separator. Full separator. Half shall not be accepted. Rip Cord is must,Insertion Loss of 32.8 db/100m at 250 MHz ,Cable should support operating temperature from -20° to +70°C Cable support Conductor Resistance ≤ 9.38 Ω/100m Max., Cable support Delay Skew: < 45 ns/100m, Operating Voltage: 72V , Impedance: 100 ± 15 Ω @100 MHz. and Propagation Delay @250 MHz : 536 ns/100m, ETL Verified 4 connector channel performance up to 700 MHz , RoHS Compliant. Make: Systimax, Legrand, Panduit
LIGHTNING PROTECTION SYSTEM Air Terminal Supply , Installation, Testing & commissioning of 8 mm Aluminum Round Conductor. Tested as per IEC 62561. (Make:OBO/ABB/DHEN)
Supply , Installation, Testing & commissioning of Roof conductor holder for parapet- Polyamide Conductor holder: With M8 female thread or diameter 7mm, M8 Screw to connect the conductor holder. Weather and temperature resistant from -35 to +90 degree Celsius tested. Conductor holder @ 1 meter distance. Tested as per IEC 62561. (Make:OBO/ABB/DHEN)
Supply , Installation, Testing & commissioning of Polyamide roof cable holder for flat roof: DIN 48829 Form B1. Closed form with bottom. Filling weight 1Kg (frost-resistant concrete). Sleeve from polyethylene, black @ 1 meter distance. Tested as per IEC 62561. (Make:OBO/ABB/DHEN)
Supply , Installation, Testing & commissioning of cross universal connector: For T and cross connection, to route vertical down conductor /mesh formation made of hot dipped galvanised iron with necessary screws etc as required. Installed with 4 hexagonal bolts M8*25 with M8 hexagonal nuts . Tested as per IEC 62561. (Make:OBO/ABB/DHEN)
Supply , Installation, Testing & commissioning of expansion piece with connector: For equalising temperature related length changes. Necessary on conductors length over 20 meters. For round conductor Rd 8/ALU. Tested for 100kA lightning current. (Make:OBO/ABB/DHEN)
Supply , Installation, Testing & commissioning of Connector: For T cross and parallel connectors. Quick installation using hexagonal bolt M10X30 high-grade hot dip galvanised. Tested as per IEC 62561.(2nos/expansion piece ). (Make:OBO/ABB/DHEN)
Supply , Installation, Testing & commissioning of 1 mtr vertical air terminal with mounting accessories on the flat surface to meet the requirements of IS/IEC 62305. Tested for Electrical , mechanical and chemical as per IEC 62561. Tested for 100kA lightning current. (Make:OBO/ABB/DHEN)
Supply , Installation, Testing & commissioning of Vertical air terminal with accessories:Providing of Air terminals as per IS-IEC -62305 part-3 Nominal size Ø10/16 mm aluminium rod: 2 Mtr Airterminal: semi-hard (E-AlMgSiO5 corresponds to DIN 48801) Suitable for high wind load. Tested as per IEC 62561. (Make:OBO/ABB/DHEN)
Supply , Installation, Testing & commissioning of Stand for Fang Fix system 16 kg with base and clamp ,made up of frost resistant concrete and clamp tested upto 100KA lightning current . (Make:OBO/ABB/DHEN)
Supply , Installation, Testing & commissioning of Stand for Fang Fix system 16 kg made up of frost resistant concrete. (Make:OBO/ABB/DHEN)
Down conductor Supply , Installation, Testing & commissioning of 8 mm Aluminum Round Conductor. Tested as per IEC 62561. (Make:OBO/ABB/DHEN)
Supply , Installation, Testing & commissioning of Polyamide Conductor holder: With M8 female thread or diameter 7mm, M8 Screw to connect the conductor holder. Weather and temperature resistant from -35 to +90 degree Celsius tested. Conductor holder @ 1 meter distance. Tested as per IEC 62561. (Make:OBO/ABB/DHEN)
Supply , Installation, Testing & commissioning of Test Joint (Folding Clamp) suitable to connect 8mm round conductor and max by 30x3 mm GI strip as specified in drawing and directed by Engineer. Tested for 100kA lightning current. (Make:OBO/ABB/DHEN)
Ring & vertical earthing system Supply , Installation, Testing & commissioning of Galvanised Steel Flat 30X3 mm thickness from earth electrode directly in ground as required. Flat conductor Hot Dipped Galvanized. Tested as per IEC 62561. (Make:OBO/ABB/DHEN)
Supply , Installation, Testing & commissioning of Cross connector for Flat: Suitable for 30mm Galvanised steel strip. Installed with 4 nos of hexagonal plate. Tested for 100kA lightning current. (Make:OBO/ABB/DHEN)
Supply , Installation, Testing & commissioning of flat conductor holder- Fit: FL 30, With mounting hole 6.2 x 22 mm, With 2 cylinder bolts M6 x 16 and over-piece from hot-dip galvanised steel, Bottom section from polyamide, black. Tested as per IEC 62561. (Make:OBO/ABB/DHEN)
Supply , Installation, Testing & commissioning of Plastic Corrosion Protection strip: Approx 1.1 mm thick. Width 50mm. Made of petrolatum- coated chemical fibre fabric. (Make:OBO/ABB/DHEN)
Supply , Installation, Testing & commissioning of UL Listed maintenance free ,Low carbon copper coated earth rod of 3 metre electrode having diameter of 14.2 mm with copper coating thickness of 250micron tested as per IEC 62561-2 (Make:OBO/ABB/DHEN)
Supply , Installation, Testing & commissioning of universal clamp made of SS to connect rod with flat conductor (Make:OBO/ABB/DHEN)
Supply , Installation, Testing & commissioning of Earth conductivity enhancing mineral compound shall be of 25 kg/pit tested as per IEC 62561-7,TCLP tested (Make:OBO/ABB/DHEN)
Supply , Installation, Testing & commissioning of The above arrangements shall be provided with Heavy duty earth champer of 5000kg load bearing capacity to ensure the safety of earthing system (Make:OBO/ABB/DHEN).
Installation of The above arrangements including all accessories as per Direction of Engg. In charge.
PANEL & CABLES SUB DISTRIBUTION PANEL FOR TRANSIT HOUSE S/I/T&Commissioning of CPRI Approved LT indoor floor mounted cubical type electrical main panel (for both light and power circuit) made out by 2mm CRCA steel sheet duly derusted & painted by simens grey powder cote paint is designed as G.A drawing. (FOR ALL MAIN CONNECTED LOAD) as per direction of Engg.-in-Charge. Warrentee period of replacement of panel & accessories must be 1 year & compelete test certificate must be submitted along with panel board including component list.3P+N Type1+ 2 65 kA SPD shall be installed in the incomer.40x10mm Separate Aluminium Earth bus bar should be installed.All the incoming and outgoing feeders shall have ON/OFF/TRIP indication. Busbar -100A AL busbar with SC rating of 25KA Electrolytic copper busbar duly sleeved by color coded PVC sleeve & supported by suitable size DMC insulator. Incomer feeder consisting of One (1) 100 Amp Moulded Case Circuit Breaker, 4P, Breaking capacity – 36 KA Thermal Magnetic Released with 3 NosIndicating lamp for ON/OFF/Trip with control fuse/ MCB, 3 Nos 100/5 A 15VA Cl 1.0 CTs, 1No - Multifunction meter (V,A,KWHr, KW, P, F)Make-Schneider(CVS)/Legrand(DPX3)/Siemens(3VA)/ABB(Formula) 100A,4P,415V Manual Changeover in Sheet Steel Enclosure,Make:LK/C&S. Outgoing Feeders consisting of Nine(9) - Outgoing Feeders : 03 Nos for PDB ,03 Nos for LDB ,01 nos for Lift DB & 02 Nos Spare each comprising of One (1) 63 Amp Moulded Case Circuit Breaker, 4P, Breaking capacity – 25 KA Thermal Magnetic Released with 3 NosIndicating lamp for ON/OFF/Trip with control fuse/ MCB, 3 Nos 70/5 A 15VA Cl 1.0 CTs, 1No - Multifunction meter (V,A,KWHr, KW, P, F)Make-Schneider(CVS)/Legrand(DPX3)/Siemens(3VA)/ABB(Formula) PANEL AS ABOVE
SUB PANEL FOR -01NOS UPS DB & 01 NOS DG POWER SUPPLY S/I/T&Commissioning of CPRI Approved LT indoor floor mounted cubical type electrical main panel (for both light and power circuit) made out by 2mm CRCA steel sheet duly derusted & painted by simens grey powder cote paint is designed as G.A drawing. (FOR ALL MAIN CONNECTED LOAD) as per direction of Engg.-in-Charge. Warrentee period of replacement of panel & accessories must be 1 year & compelete test certificate must be submitted along with panel board including component list.3P+N Type1+ 2 65 kA SPD shall be installed in the incomer.40x10mm Separate Aluminium Earth bus bar should be installed.All the incoming and outgoing feeders shall have ON/OFF/TRIP indication. Busbar -100A AL busbar with SC rating of 50KA Electrolytic copper busbar duly sleeved by color coded PVC sleeve & supported by suitable size DMC insulator. Incomer feeder consisting of One (1) 63 Amp Moulded Case Circuit Breaker, 4P, Breaking capacity – 25 KA Thermal Magnetic Released with 3 NosIndicating lamp for ON/OFF/Trip with control fuse/ MCB, 3 Nos 70/5 A 15VA Cl 1.0 CTs, 1No - Multifunction meter (V,A,KWHr, KW, P, F)Make-Schneider(CVS)/Legrand(DPX3)/Siemens(3VA)/ABB(Formula) Outgoing feeder consisting of SIX (6) 32 Amp ,415V,10KA,C-CURVE,FP,MCB( Make-LEGRAND-DX3/ Siemens-Betaguard/ Schneider- Acti 9/ABB SB 200) PANEL AS ABOVE
Earthing Supplying,installation,testing & commissioning of materials and installation of Copper earth plate 600mmx600mmx3.15mm thick ISI marked with G. I. nut bolts & washers including cost of burnt wood charcoal, salt, foreign soil, water pouring arrangements, brick masonary enclosure on top with removable RCC cover complete with labour for excavation of pit in all kinds of soil & rock as required and as per direction of Engineer-in-charge.The entire earthing system should be Replacement Warranty will be 2 years
Supplying,installation,testing & commissioning of materials and installation of GI earth plate 600mmx600mmx6mm thick ISI marked with G. I. nut bolts & washers including cost of burnt wood charcoal, salt, foreign soil, water pouring arrangements, brick masonary enclosure on top with removable RCC cover complete with labour for excavation of pit in all kinds of soil & rock as required and as per direction of Engineer-in-charge.The entire earthing system should be Replacement Warranty will be 2 years
Providing and fixing 50mm x 6 mm GI strip on surface or in recess for connections etc. as required as per direction of Engg.-in-Charge.
Providing and fixing 25mm x 5 mm GI strip on surface or in recess for connections etc. as required as per direction of Engg.-in-Charge.
Providing and fixing 6 SWG GI wire on surface or in recess for loop earthing along with cables etc as required.
Providing and fixing 8 mm dia copper wire on surface or in recess for loop earthing as required.as per direction of Engg.-in-Charge.
Cable Supply Supplying & Testing of 1.1 KV grade Aluminium XLPE armoured power cable of following size suitable for 415 Volt, 3Ph, 50 c/s supply. 3.5C X 50 sqmm Al
3.5C X 35 sqmm Al
Supplying & Testing of 1.1 KV grade cupper XLPE armoured power cable of following size suitable for 415 Volt, 3Ph, 50 c/s supply. 4C X 6 sqmm
Cable laying Laying of one number of PVC insulated and PVC seathed / XLPE power cable of 1.1 KV grade of size in the existing RCC/HUME/STONEWARE/METAL pipe as required. Above 25 sqmm and upto400 sqmm
Laying and fixing of one number of PVC insulated and PVC seathed / XLPE power cable of 1.1 KV grade of size not exceeding 25 sq.mm on surface as required. upto 25 Sqmm
TERMINATION OF CABLES :- Supply & Making end Termination with brass compression gland and aluminium lugs for PVC insulated and PVC sheathed cable of 1.1 kv grade (without cost of Cable) 3.5C X 50 sqmm Al
3.5C X 35 sqmm
4CX 6 sqmm
Providing,fixing and laying of fallowing dia PN16 HDPE pipe 63mm(medium class) in ground complete with fitting incl. trenching(75 mm depth)and refilling as per direction of Engg.-in-Charge.
CABLE TRAY Supplying instalaltion hot dip galvanized perforated type cable tray with perforation not more than 17.5% of following size including installation along wall/ suspended from ceiling with brackets/ threaded suspenders including bends etc as required Make-Profab/OBO/Neidax. 200 mm (W) X 60 mm (H) with 1.6 mm thick sheet
400 mm (W) X 60 mm (H) with 1.6 mm thick sheet
SITC of HT Rubber mat 1m X 2m
SITC of Shock treatment chart.
DOOR KEYCARD SWITCH Supply,Installation,Testing& Commisioning of key card switch with all acessories.Make:Legrand/Hikvision.
Supply,Installation,Testing& Commisioning of key fob for key card switch with all acessories.Make:Legrand/Hikvision.
Please Enable Macros to View BoQ information
stage.html
html • 0.06 MB
technical_573063.pdf
techsummary_573063.pdf
finance_573063.pdf
BOQ Comparative Chart
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.82 MB
BOQ_573063.xls
BOQ • 0.63 MB
DTCN1.pdf
Tender Documents • 1.18 MB
Download all tender documents and submit your bid