Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 01₹19.0 LAccepted-AOC | 01 | Accepted-AOC FOUND LOWEST AND REASONABLE HENCE TENDER ACCEPTED | |
| 2 | 02₹21.5 L+₹1.8 L (9.17%)Rejected-AOC | 02 | Rejected-AOC NOT LOWEST | |
| 3 | 03₹22.5 L+₹2.8 L (14.4%)Rejected-AOC | 03 | Rejected-AOC NOT LOWEST | |
| 4 | 04₹31.9 L+₹12.2 L (61.7%)Rejected-AOC | 04 | Rejected-AOC NOT LOWEST |
Tender Value
₹25.0 L
EMD Value
₹50,000
Closing Date
4 May 2023, 6:00 pmClosed
SHRI MAHAVIR SINGH, IDSE, GE (SOUTH)
GARRISON ENGINEER (SOUTH), MUDFORT, SECUNDERABAD PIN - 500003
REPAIRS REPLACEMENT OF INTERNAL ELECTRIFICATION AND ITS CONNECTED WORKS AT DIV UNITS 454, FD HOSP AND MD ACCN UNDER GE SOUTH SECUNDERABAD
2023_MES_587230_1
GE(S)/SEC/TOKEN-48 OF 2022-23
Open Tender
Electrical and Maintenance Works
Item Wise
330 days
GE SOUTH, MUDFORT, SECUNDERABAD
For Enlisted contractors class E and above category b (i) and for unenlisted contractors meeting the eligibility criteria of above class and category for along eligible class with EMD
6 documents required · 6 mandatory
₹500
GARRISON ENGINEER (SOUTH), MUDFORT, SECUNDERABAD
₹50,000
Yes
14 Jun 2023
27 Mar 2023
6 May 2023
27 Mar 2023
4 May 2023
11 Apr 2023
27 Mar 2023 - 10 Apr 2023
Amount
Taking down existing unserviceable point wiring of any type/ size of light/fan/power/two way/bell etc on TW batten/conduit including removal of batten / conduit / gutties / wooden boards / switches / sockets / regulators/ light fittings etc and removal of unserviceable material out of site area all as specified & directed by Engg in Charge.
Taking down existing unserviceable light fittings,security light fittings,bulk head fittings,fall ceiling light fittings etc. from any height of building complete all as specified and as directed
Taking down existing unserviceable MCB's/MCCB's/Distribution boards any capacity complete all as specified and as directed
S & F switch piano single pole flush type 5 amps, 230 volts. complete all as specified and as directed
S & F switch piano single pole flush type 15 amps, 230 volts complete all as specified and as directed
S & F single pole Modular switch 1 way 6 Amps, 1 Module complete all as specified and as directed
S & F single pole Modular switch 1 way 16 Amps, 1 Module complete all as specified and as directed
S & F Switch piano two way flush type 5 Amps capacity 230 volts complete all as specified and as directed
S & F Modular switch 2 way 6 Amps, 1 Module complete all as specified and as directed
S&F bell push 5 A flush type complete all as specified and as directed
S&F Modular Bell Push 6A, 1 Module complete all as specified and as directed
Supply and fix socket outlet modular type multipurpose 2/3 Pin, 6 amps, 230 volts combined 2 Module complete all as specified and as directed
Supply and fix socket outlet modular type multipurpose 3/5 Pin, 6/16 amps, 230 volts combined 2 Module complete all as specified and as directed
Supply and fix socket outlet flush type multipurpose 2 in 1, 3 Pin, 5 amps, 230 volts complete all as specified and as directed
Supply and fix socket outlet flush type multipurpose 2 in 1, 3 Pin, 5/15 amps, 230 volts complete all as specified and as directed
S & F switch socket combination flush type multipurpose 2/3 pin 5 amps 2 in 1 230 Volts complete all as specified and as directed
S & F switch socket combination 5 in 1 multipurpose 3/5 pin 5/15 amps flush typewith complete all as specified and as directed
S & F Modular ceiling fan regulator stepped socket size (modular) suitable to work on 230 volts complete all as specified, 2 Module complete all as specified and as directed
S & F electronic type regulator single module stepped heavy duty for ceiling fan suitable to work on 230 volts complete all as specified and as directed .
S & F electronic type regulator two module stepped heavy duty for ceiling fan suitable to work on 230 volts complete all as specified.
S&F bell (buzzer/ding dong) working on 230 volts AC Supply complete all as specified and as directed
S & F lamp holder insulated body surface bakelite with back plate suitable for angle / batten fittings complete all as specified and as directed
S & F wall mounted 2 ft LED batten of 12 watt with LED Lamp, extruded aluminium heat sink provided for efficient heat dissipation & integrated electronic driver complete all as specified and as directed . Make : Phillips Cat No.BN021LED12S PSU CW GR or its equivalent makes as specified here-in-after.
S & F 4 ft box type tube light fitting with LED Tube rod of 18/22 watt , extruded aluminium heat sink provided for efficient heat dissipation & integrated electronic driver complete all as specified here-in-after.
Supply and Fix 4ft LED Batten of 18/20/22 Watt with alumium housing & integrated electronic driver complete all as specified and as directed Make : Phillips Cat No.BN022LED40S-6500 PSU or its equivalentmakes as specified here-in-after.
Supply and Fix 4ft LED tube rods of 18/20/22 Watt complete all as specified and as directed Make: Philips/Wipro /Crompton
S & F Security Light of 25 watt with single die ceramic base high power LED light source with IP66 protection,PDC housing & aesthetic finess disign and high impact resistance(IK08) toughened glass cover and street light optics for lighting of internal B2 category for outdoor lighting suitable for bracket dia 32mm to 40mm having color temparature 4000K complete with necessary fixing arrangements such as GI braket of suitable length,nut,bolt,washers etc complete as specified and as directed . Make : Philips Cat No. BRP052 P LED025 CW SLMR FG S1PSU GR or its equivalent makes as specified here-in-after.
M & L for Point wiring complete with two runs of 1.5 Sq mm copper conductor (for Phase and neutral) PVC insulated unsheathed multi stranded ,copper conductor FRLSH cable of 1100V grade confirming to IS- 694 drawn through and including new non metallic rigid PVC conduit medium grade , ISI marked , 20 mm bore with conduit accessories surface mount on wall or fixed on ceiling/roof/truss/columns etc,including provision of fabricated branded pressed steel terminal box of suitable sizes with 1.6mm thickness duly painted inner and outer side by anti corrosive paint for housing the modular switches,sockets,fan regulators etc and covered with 3mm thick steel plates complete concealed in walls and provn of 1.5 Sqmm PVC insulated unsheathed copper conductor cable of green colour to common earth dolly etc. complete all as specified and as directed for one light point controlled by one switch. Note: The wiring shall be done in proper color coding using red,yellow,blue for phases , black for neutral and green for earth
All as per Sl item No. 28 here in before, but for One 3 pin 5 Amps switch socket outlet point controlled by one switch on independent board makes as specified here-in-after..
All as per Sl item No. 28 here in before, but for One Bell point controlled by one, one way switch 5 amps, SP makes as specified here-in-after.
All as per Sl item No. 28 here in before, but for One 3 pin 5 Amps switch socket outlet point controlled by one switch on the same board makes as specified here-in-after.
All as per Sl item No. 28 here in before, but for One light point controlled by two 2 - way switch 5 amps, SP makes as specified here-in-after.
M & L for Point wiring complete with two runs of 1.5 Sq mm copper conductor (for Phase and neutral) PVC insulated unsheathed multi stranded ,copper conductor FRLSH cable of 1100V grade confirming to IS- 694 drawn through and including new PVC casing caping , ISI marked , including provision of fabricated branded pressed steel terminal box of suitable sizes with 1.6mm thickness duly painted inner and outer side by anti corrosive paint for housing the switches,sockets,fan regulators etc and covered with 3mm thick plastic laminated sheet cover with cadmium plated screw ,cup washer etc. complete concealed in walls and provn of 1.5 Sqmm PVC insulated unsheathed copper conductor cable of green colour to common earth dolly etc. complete all as specified and as directed for one light point controlled by one switch. Note: The wiring shall be done in proper color coding using red,yellow,blue for phases , black for neutral and green for earth
All as per Sl item No.33 here in before, but for One 3 pin 5 Amps switch socket outlet point controlled by one switch on independent board .
All as per Sl item No.33 here in before, but for One Bell point controlled by one, bell push
All as per Sl item No.33 here in before, but for One light point controlled by two 2 - w a y s w i t c h 5 amps, SP
All as per item No .33 Above but point wiring of 2.5 Sqmm Copper conductor
M & L for Point wiring complete with two runs of 1.5 Sq mm copper conductor (for Phase and neutral) PVC insulated unsheathed multi stranded ,copper conductor FRLSH cable of 1100V grade confirming to IS- 694 drawn through and including new non metallic rigid PVC conduit medium grade , ISI marked , 20 mm bore with conduit accessories concealed in wall /floor and fixed on ceiling/roof/truss/columns etc,including provision of fabricated branded pressed steel terminal box of suitable sizes with 1.6mm thickness duly painted inner and outer side by anti corrosive paint for housing the switches,sockets,fan regulators etc and covered with 3mm thick plastic laminated sheet cover with cadmium plated screw ,cup washer etc. complete concealed in walls and provn of 1.5 Sqmm PVC insulated unsheathed copper conductor cable of green colour to common earth dollyetc. complete all as specified and as directed for one light point controlled by one switch. Note1: The wiring shall be done in proper color coding using red,yellow,blue for phases , black for neutral and green for earth Note 2: The cost of cutting of chases of required width and depth for conduit including plastering ,painting two coats to match with the existing wall colour is deemed to be included in the rate quoted in case of concealed wiring
All as per Sl item No 38 above but for One ceiling fan/exhaust fan point controlled by one switch through regulator.
All as per Sl item No 38 above, but for One 5 Amps socket outlet point on the independent board.
All as per Sl item No 38 above, but for One 5 Amps socket outlet point on the same board.
All as per Sl item No 38 above but for One light point controlled by two way switch
M & L for Point wiring complete with two runs of 2.5 Sq mm copper conductor (for Phase and neutral) PVC insulated unsheathed multi stranded ,copper conductor FRLSH cable of 1100V grade confirming to IS- 694 drawn through and including new non metallic rigid PVC conduit medium grade , ISI marked , 20 mm bore with conduit accessories concealed in wall /floor and fixed on ceiling/roof/truss/columns etc,including provision of fabricated branded pressed steel terminal box of suitable sizes with 1.6mm thickness duly painted inner and outer side by anti corrosive paint for housing the switches,sockets,fan regulators etc and covered with 3mm thick plastic laminated sheet cover with cadmium plated screw ,cup washer etc. complete concealed in walls and provn of 2.5 Sqmm PVC insulated unsheathed copper conductor cable of green colour to common earth dollyetc. complete all as specified and as directed for one light point controlled by one switch. Note1: The wiring shall be done in proper color coding using red,yellow,blue for phases , black for neutral and green for earth Note 2: The cost of cutting of chases of required width and depth for conduit incl plastering ,painting two coats to match the existing wall colour is deemed to be included in the rate quoted in case of concealed wiring
All as per Sl item No. 43 here in before, but for using 4 Sqmm single core copper conductor cable of multistranded PVC insulated sheathed FRLSH 1100 Volts grade for 3 Pin 15 Amps switch socket combination point on independent board including running of 4 Sq mm copper conductor PVC insulated cable as earth continuity conductor complete all as specified and as directed
M & L for bracket made out of GI pipe of suitable dia not less than 1.2 mtr long and fixed on walls with 2 nos MS clamps made out of MS flat of suitable size thick complete with MS nuts, bolts and washers etc bent to required shape complete including taking down all as specified and as directed
S & F for 15 Watt recess mounted circular downlight with white powder coated polycarbonate housing and pressure diacast , heat sink having high efficiency all as specified and as directed
S & F for 15 Watt surface mounted circular downlight with white powder coated polycarbonate housing and pressure diacast , heat sink having high efficiency all specified and as directed
S & F 24 watt recess softline luminaire (1x1) suitable for armstrong/grid ceiling with high brightness white LEDs and PMMA extruded diffuser giving glare free light and good aesthetic appeal complete all as specified and as directed
S & F for recess softline luminaire 2 ft x2 ft fittings of 42 watts all as specified and directed. Make : Phillips Cat No.SC380B LED30S-6500 G5 L42W60 PSD OD or its equivalent makes as specified here-in-after.
S & F for recess softline luminaire 2x2 fittings of 36 watts SURFACE MOUTED all as specified and directed. Make : Phillips Cat No.SC380B LED30S-6500 G5 L60W60 PSD OD or its equivalent makes as specified here-in-after
S & F for 10 watt bulk head luminaire suitable for outdoor with high brightness giving glare free light and complete all as specified and as directed.
S & F of MCB SP 6 to 32 Amps 240 volts all as specified and as directed
S & F of MCB SPN 16 to 32 Amps 240 volts all as specified and as directed
S & F in replacement of MCB SPN 40 to 63 Amps 240 volts all as specified and directed
S & F MCB TPN, 415 volts suitable for fixing in MCB DB of capacity 63 Amps,10 KA all as specified and directed
S & F MCB Four pole, 415 volts suitable for fixing in MCB DB of capacity 100 Amps making good the distrubed surface to match with the existing surface complete all as specified and as directed.
S & F sheet metal enclosure MCB DB SPN 4 way with 100 amps rated bus bar 240 volts double door with locking system complete all as specified and as directed.
All as per Sl item No 57 here in before, but SPN 8 way DB complete all as specified and as directed
All as per Sl item No 57, here in before but SPN 12 way DB complete all as specified and as directed
S & F TPN DB 4 way double door made out of CRCA sheet housing duly powder coated & confirming to IS specification complete all as directed .
S & F Vertical loadline type TPN DB 4 way double door with incoming as MCCB TP 415 volts AC 3 phase 50 Hz with fixed magnetic setting for current rating of 63 Amps 16 KA ,4P made out of CRCA sheet housing duly powder coated & confirming to IS specification with busbar rating not less than 160 A complete all as specified and as directed.
S & F Single pole and Neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB 20 Amps (AC Box) complete all as specified and as directed .
S&F MCCBs 415V,25KA, 100 amps 4 Pole suitable for DB including removing the existing unserviceable one complete all as specified and as directed
All as per Sl item No 63 here in before, but 63 Amps, 10 KA complete all as specified and as directed.
M & L for Submain wiring with 2 runs of single core 4 sqmm PVC insulated FRLS multistranded 1100 volts grade wire, copper conductor drawn through and including non-metalic rigid PVC conduit and conduit accessories of medium grade not not less than 25mm dia including one run of single core 4 sqmm PVC insulated sheated multistranded 1100 volts grade with copper conductor cable as earth continuty conductor along with the wiring and connected from DB to DB/main board including removing the existing unserviceable submain riwing complete all as specified and as directed.
All as per Sl item No 65, but 2 runs of single core 6 sqmm and one run of single core 6 sqmm as earth continuty conductor complete all as specified and as directed. Note for item No : 65 & 66 :- 2 runs of cable one run of earth wire and one run of PVC conduit will be measured as one unit length
M & L for Submain wiring with 4 runs of single core 6 sqmm PVC insulated FRLS multistranded 1100 volts grade wire, copper conductor drawn through and including non-metalic rigid PVC conduit and conduit accessories of medium grade not not less than 25mm dia including one run of single core 6 sqmm PVC insulated sheated multistranded 1100 volts grade with copper conductor cable as earth continuty conductor along with the wiring and connected from DB to DB/main board including removing the existing unserviceable submain riwing complete all as specified and as directed.
M & L for Submain wiring with 4 runs of single core 10 sqmm PVC insulated FRLS multistranded 1100 volts grade wire, copper conductor drawn through and including non-metalic rigid PVC conduit and conduit accessories of medium grade not not less than 25mm dia including one run of single core 10 sqmm PVC insulated sheated multistranded 1100 volts grade with copper conductor cable as earth continuty conductor along with the wiring and connected from DB to DB/main board including removing the existing unserviceable submain wiring complete all as specified and as directed. Note for item No : 67 & 68 :- 4 runs of cable one run of earth wire and one run of PVC conduit will be measured as one unit length
M & L for submain wiring / point wiring with 2 runs of single core 1.5 sqmm PVC insulated FRLS multistranded 1100 volts grade wire, copper conductor drawn through in existing PVC conduit and conduit accessories including one run of single core 1.5 sqmm PVC insulated sheated multistranded 1100 volts grade with copper conductor cable as earth continuty conductor along with the wiring and connected from DB to DB/main board including removing the existing unserviceable submain riwing complete all as specified and as directed.
All as per item No.69 above but of copper conductor size 2.5 Sqmm
All as per item No.69 above but of copper conductor size 4.0 Sqmm Note for item No. 69 to71 :- 2 runs of cable, one run of earth wire will be measured as one unit length
All as per item No.69 above but of copper conductor size 6 runs x 6.0 Sqmm Note : 6 runs of cable, one run of earth wire will be measured as one unit length
Supply and replace Electronic Driver for downlight of any capacity/Watt as per site requirement all as specified and as directed
Supply and replace Electronic Driver for LED Light of 2X2 fitting of any capacity/Watt as per site requirement all as specified and as directed.
M & L for removing repairing any kind of LED building security light of any wattage by replacing the defective parts,complete replacement of all LED chips,correction of LED PCB circuits in any means including soldering to make it functional and refixing it complete all as specified and as directed
M & L for repairs to copper inner container like denting, soldering, brazing, leak testing and reassembling of any Ltrs capacity water heater (Geyser) complete all as specified and as directed by Eng-in-Charge
Supply and replace Geyser element 2000 watts /1500watts of any type or as per site requirement complete all as specified and as directed
Supply and replace Thermostat suitable for existing geyser of any make complete all as specified and as directed
Supply and replace Indicator bulb 230 V suitable for any make and colour complete all as specified and as directed.
Supply and replace PVC Cold/Hot water connection pipe 45 cms long 15 mm dia complete all as specified and as directed
S &F Bib taps chromium plated with crutch or butter fly handle 15 mm dia screwed for iron pipe or for brass ferrule and fixed including cutting of GI pipeall as specified and as directed.
M & L Rewinding of burnt ceiling fan of 1200 mm sweep motor with supper enameled copper wire of suitable size including repainting it white colour incl transportation complete all as specified and directed Note: Bearing,shaft,capacitor,lock pins,clamps,rubber bushes etc..will be measured and paid under respective item of the schedule
M & L Rewinding of burnt Exhaust fan of 225 / 300mm sweep motor with supper enameled copper wire of suitable size including repaintingas per site requirement, replacement of sealed bearing and shaft of any make, type, model incl transportation complete all as specified and directed.
All as per Sl item No. 83 here in before, but for 450mm sweep exhaust fan complete all as specified and as directed
Supply and replace Fan condenser 2.5 mfd complete all as specified and as directed
Supply and replacement of sealed bearing and shaft suitable for 1200 mm ceiling fan all as direted by Engineer-in-charge.
Supply and replace fan condenser of 4.00 Mfd complete all as specified and as directed
Supply and replace split pins/lock pins for ceiling fans complete all as specified and as directed
Supply and replace MS Clamp with rubber bushes, bolts & nuts for ceiling fan along with lock pin complete all as specified and as directed
S&F only ceiling fan down rods of required height fabricated out of 15/20mm dia GI pipe medium grade fixing duly threaded/hole driled with suitable check nut and drilled hole for split pin and painting the down rod for ceiling fan 1200 to 1400mm sweep and complete all as specified and as directed
S & F ceiling rose three terminal surface bakelite type AC 50 Hz 230 volts of size 65 x 50 mm complete all as specified and as directed.
Supply and replace PVC rectangular box (Gang box) with 5 Amps switch socket complete all as specified and as directed
Supply and replace PVC rectangular box (Gang box) with 5/15 Amps switch socket all as direted by Engineer-in-charge.
Supply and fix/lay GI pipe 15 mm dia med grade for protection of earth continuity conductor complete all as specified and as directed
Supply and replace Plug top 5 Amps 3 pin 250 Volts complete all as specified and as directed
Supply and replace Plug top 15 Amps 3 pin 250 Volts complete all as specified and as directed
Supply and replace PVC Round blocks complete all as specified and as directed
Supply and replace PVC Dummy sheets circular type of 4" complete all as specified and as directed
Supply and replace PVC Dummy sheets circular type of 6" acomplete all as specified and as directed
S & F LED 9 Watt /11 Watt lamp suitable for B22 base holder complete all as specified and as directed
M&L for Cutting chases, pinning in. making good to facings where required and pointing in cement mortar 1:3 to ends or edges of andings, steps, cills, sunshades, shelves, lintels, etc.; and cutting chases for concealed conduit wiring, etc., making good and matching with the existing colour, cutting not exc 10 cm girth complete all as specified and as directed
Supply and fix in replacement of white hylam plain laminate sheet of thickness complete all as specified and as directed
S & F Supplying and fixing 1100 volts grade heavy duty cable PVC insulated aluminium conductor of size 4 core 10 Sqm, served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 metre apart including4mm suspension wire, one twin core cable flat or circular as per site requirement all as specified and directed .
M&L for checking and measuring of earthing resistance value of building indicated by removing and isolating earth conductor from test terminal block and measure the earth resistance using digital ohm meter(Earth resistance tester) and note down the readings and refixing all earthing items in original position, obtain the signatures of authority concerned complete all as directed by Engineer in charge Note1: Testing to be done by qualified technician/electrician in the presence of MES authorities . Note2: Contractor should arrange labour & testing equipment along with necessary connecting copper wires , earth rods all misc items required for satisfactory completion of job and is deemed to be included in the rate quoted
Disconnection and removing the existing unserviceable earthing and M & L of Earthing complete with galvanised steel earth plate electrode 60cm x 60cm x 6mm thick burried directly in ground to a depth not less than 2.25 m below ground level with top edge of earth plate not less than 1.5 m below normal ground level connected to GI earth lead wire 4 mm dia by means of bolts, nut, check nuts and washers etc of galvanised iron and earth lead protected by provision of GI pipe 15 mm bore of medium grade from earth electrode to DBs/Main switch all as shown in Electrical Plate No 3 of SSR Part I and connected to main switch board including excavation and earth work in any type of soil, PCC chamber in 1:2:4 Type B-1 using 20 mm graded stone aggregate 75 mm thick RCC cover in 1:2:4 type B-1 reinforced with 6mm dia bars at 75mm c/c both ways with 12mm dia MS bar handle made to shape, 20 mm dia medium grade GI watering pipe perforated at bottom with funnel and wire mesh, common salt and charcoal filling complete including testing on completion all as specified (Note: GI pipe 15mm dia & GI earth lead 4mm dia upto 7.5 m length is deemed to be included in quoted rate).
M & L in replacement of Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc as required 4mm dia galvanised iron or steel wire
Disconnection and removing the existing unserviceable earthing and M & L of Earthing complete with copper earth plate electrode 60cmx60cmx3 mm thick electrode buried directly in ground earth pit not less than 2.25 m deep below normal ground level) with top edge of earth plate not less than 1.5 m below ground level connected to copper earth strip 20x3 mm by means of bolts, nuts, check nuts and washers etc of copper and earth lead protected by provision of GI pipe 40 mm bore of medium grade from earth electrode to test point incl provn of concrete pit in PCC(1:2:4) type B-1 using 20 mm graded stone aggregate with 40 mm thick cover of RCC (1:2:4) reinforced with XPM (Weight not less than 4 Kg/Sqm) PCC cover with handle and with 6 mm dia MS bar handle made to shape, GI pipe medium grade 20 mm bore pipe for watering perforated at bottom1.75 mtr long placed on top edge of earth plate, common salt (100 KG) and charcoal(100 KG) and BFC(100KG) compound filling with alternate layers test point made out of Bronze/Gun metal with fixing arrangement, funnel, wire mesh and earth work in hard/dense soil, returning in and removal of surplus soil to a distance not exceeding 50 mtr, all as per Electricalplate No 5 of SSR Part-I and connection to earth test point all as specified incl testing on completion. (Note1: copper earth strip and protection pipe 40 mm bore GI medium grade beyond 7.5 mtr will be measured and paid seperately under the respective item of the schedule Note2: Testing of earth resistance done by the qualified technician/electrician at his own arrangements and maximum acceptable earth resistance should be less than 5 Ohm . Note3: Test Terminal block ,Copper strip 20 x 3 & GI pipe 40 mm up to 7.5 Mtr are included in the rate quoted by the contractor
Supply and fix in replacement of copper strip Copper strip 20 x 3 mm with saddles and fixing screws etc. for roof conductors and down conductors above ground complete all as directed and as specified.
Supply and fix in replacement of Copper strip 32 x 6mm buried in ground as continue earth lead from copper earth plate to test terminal point for complete all as directed and as specified.
Supply and lay in replacement of 'Medium grade',galvanised steel tube of dia 40 mm ,on roof for fixing of lightening arrester including taking down with necessary fixing arragements using PCC complete all as directed and as specified.
S & F twin core flexible twisted copper conductor wire 1.1 KV for Phase(Red) and neutral(Black) for connecting light/switch /socket etc. as per site requirement including taking down old unserviceable one complete all as directed and as specified.
M&L for Aluminium strip 25 x 3mm with saddles and fixing screws etc. for roof conductors and down conductors above ground including takingdown old unserviceable one complete all as directed and as specified.
M&L for cutting of road / hard standing upto 0.3m in depth and 0.45m wide for laying of lightening conductor protection pipe including refilling, watering, well ramming and finishing with PCC 1:3:6 and matching with surroundings, removing the broken P.C.C / road materials and clearing the site complete all as directed by Engineer-in-Charge. Note : Earth work and PCC will be measured and paid seperately under the respective item of the schedule.
M & L for PCC (1:3:6) type C2 with 40mm grade aggregate in foundations,filling and mass concrete incl demolition of existing PCC work complete all as directed and as specified.
SUN LIGHT HOUSE
Dwarka Pershad Radhey Ramanlal
G.MADAN MOHAN
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .