Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹36.2 LAccepted-AOC | 1 | Accepted-AOC Accepted being L1 | |
| 2 | 2₹36.4 L+₹19,267 (0.53%)Rejected-Finance | 2 | Rejected-Finance Rejected being not L1 | |
| 3 | 3₹37.2 L+₹95,121 (2.63%)Rejected-Finance SHOP NO 13 45 FEET ROAD BHARAT COLONY FARIDABAD HARYANA 121014 | FARIDABAD | HARYANA | 121014 | 3 | Rejected-Finance Rejected being not L1 | |
| 4 | 4₹42.1 L+₹5.9 L (16.4%)Rejected-Finance | 4 | Rejected-Finance Rejected being not L1 | |
| 5 | 5₹42.4 L+₹6.2 L (17.1%)Rejected-Finance | 5 | Rejected-Finance Rejected being not L1 |
| Sl No | Description | Qty | Unit | mayur enterprises L7 | MV Engineers And Contractors L8 | Rajindera Enterprises L4 | DS CONSTRUCTION L5 | KISHORE ENTERPRISES L2 | Vijay Electricals L10 | M/s JAIMAA ASSOCIATES L1 | Haryana EngineerService L3 | SB ENTERPRISES L6 | M P TYAGI ENGINEERS AND CONTRACTORS L9 |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 1.00 | Material and labour for excavation in trenches not exceeding 1.5 meter wide and not exceeding 1.5 meter in depth and getting out in soft/loose soil for foundation of poles, stays, laying of cables, etc complete all as specified and directed by Engineer-in-Charge. | 350 | Cum | 100 ₹35,000 | 120 ₹42,000 | 100 ₹35,000 | 100 ₹35,000 | 90 ₹31,500 Lowest | 199 ₹69,650 | 180 ₹63,000 | 149 ₹52,150 | 99 ₹34,650 | 100 ₹35,000 |
| 2.00 | Material and labour for returning filling including spreading, levelling watering and well ramming in layers not exceeding 25 cm thick in hard/dense soil complete all as specified and directed by Engineer-in-Charge. | 245 | Cum | 20 ₹4,900 | 19 ₹4,655 Lowest | 30 ₹7,350 | 20 ₹4,900 | 50 ₹12,250 | 38 ₹9,310 | 40 ₹9,800 | 49 ₹12,005 | 19 ₹4,655 Lowest | 20 ₹4,900 |
| 3.00 | Material and labour for removing excavated surplus hard/dense soil to a distance not exceeding 50 m and depsoiting where directed at a level not exceeding 1.5 m above the starting point complete all as specified and directed by Engineer-in-Charge. | 105 | Cum | 20 ₹2,100 | 19 ₹1,995 Lowest | 30 ₹3,150 | 20 ₹2,100 | 49 ₹5,145 | 38 ₹3,990 | 40 ₹4,200 | 49 ₹5,145 | 19 ₹1,995 Lowest | 30 ₹3,150 |
| 4.00 | Material and labour for river washed and screened, dry sand for filling in trenches below and around underground cables and in substation ducts for cushioning of cables etc, complete all as specified and directed by Engineer-in-Charge.
NOTE :- Measurement should be after punning down | 80 | Cum | 500 ₹40,000 | 260 ₹20,800 | 150 ₹12,000 Lowest | 300 ₹24,000 | 500 ₹40,000 | 299 ₹23,920 | 300 ₹24,000 | 599 ₹47,920 | 159 ₹12,720 | 400 ₹32,000 |
| 5.00 | Supply & fixing of sub class B bricks having minimum compressive strength 75 Kg/ Sq cm laid in trenches for cable protection etc complete all as specified and directed by Engineer-in-Charge. | 8,695 | Each | 7 ₹60,865 | 5 ₹43,475 | 2 ₹17,390 Lowest | 3 ₹26,085 | 3 ₹26,085 | 49 ₹4,26,055 | 3 ₹26,085 | 3 ₹26,085 | 2.59 ₹22,520.05 | 2 ₹17,390 Lowest |
| 6.00 | Dismantling concrete poles/ struts incl any size complete all as specified and directed by Engineer-in-Charge. | 80 | Each | 2,000 ₹1,60,000 | 2 ₹160 Lowest | 1,000 ₹80,000 | 20 ₹1,600 | 200 ₹16,000 | 999 ₹79,920 | 500 ₹40,000 | 400 ₹32,000 | 499 ₹39,920 | 100 ₹8,000 |
| 7.00 | Re-fixing only of LED Street light retrived from item No-6 complete all as specified and directed by Engineer-in-Charge. | 80 | Each | 100 ₹8,000 | 100 ₹8,000 | 200 ₹16,000 | 20 ₹1,600 Lowest | 49 ₹3,920 | 999 ₹79,920 | 200 ₹16,000 | 199 ₹15,920 | 39 ₹3,120 | 100 ₹8,000 |
| 8.00 | Re-fixing only of KIOSK Box retrived from item No-6 complete all as specified and directed by Engineer-in-Charge. | 80 | Each | 100 ₹8,000 | 100 ₹8,000 | 200 ₹16,000 | 20 ₹1,600 Lowest | 49 ₹3,920 | 999 ₹79,920 | 100 ₹8,000 | 199 ₹15,920 | 39 ₹3,120 | 100 ₹8,000 |
| 9.00 | Supply and laying or fixing or passing through pipe, 1100 volts grade heavy duty cable with PVC insulated aluminium conductor served with an inner sheathing of PVC tape armoured with galvanised steel wire or tape and overall PVC sheathed 6 sq. mm 2 core nominal cross section in service connections complete all as specified and directed by Engineer-in-Charge after removing the old/damage cable. | 500 | RM | 110 ₹55,000 | 3 ₹1,500 Lowest | 50 ₹25,000 | 50 ₹25,000 | 50 ₹25,000 | 200 ₹1,00,000 | 80 ₹40,000 | 99 ₹49,500 | 69 ₹34,500 | 100 ₹50,000 |
| 10.00 | Supply and laying of XLPE insulated heavy duty electric, un armoured cables 16 sqmm 4 core with aluminium conductor, 1100 volts grade for necessary connection with suitable lugs & fixing arrangement with necessary clamps & cable glands etc complete all as specified and directed by Engineer-in-Charge after removing the old/damaged cable. | 1,000 | RM | 135 ₹1,35,000 | 131 ₹1,31,000 | 100 ₹1,00,000 Lowest | 165 ₹1,65,000 | 110 ₹1,10,000 | 200 ₹2,00,000 | 125 ₹1,25,000 | 249 ₹2,49,000 | 109 ₹1,09,000 | 150 ₹1,50,000 |
Tender Value
₹46 L
EMD Value
₹92,000
Closing Date
30 Jun 2025, 6:00 pmClosed
GE UTILITY ELECTRIC SUPPLY
GE UTILITY ELECTRIC SUPPLY DELHI CANTT-10
REPAIR AND MAINTENANCE OF STREET LIGHTS, LT CABLES, POLE BOX ASSEMBLY, TIMER PANELS AT KABUL LINE, BAIRD PLACE, KOTWALI LINE, CEDZ OFFICE, CDA (ARMY) AND ASSOCIATED AREA UNDER AGE SLDC ES UNDER GE U ELECTRIC SUPPLY DELHI CANTT 10
2025_MES_711326_1
GE ELECT/D-26/2025-26
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE UTILITY ELECTRIC SUPPLY
AS PER TENDER DOCUMENT
7 documents required · 7 mandatory
₹500
Yes
GE UTILITY ELECTRIC SUPPLY
₹92,000
Yes
30 Aug 2025
30 May 2025
1 Jul 2025
30 May 2025
30 Jun 2025
23 Jun 2025
Amount
Material and labour for excavation in trenches not exceeding 1.5 meter wide and not exceeding 1.5 meter in depth and getting out in soft/loose soil for foundation of poles, stays, laying of cables, etc complete all as specified and directed by Engineer-in-Charge.
Material and labour for returning filling including spreading, levelling watering and well ramming in layers not exceeding 25 cm thick in hard/dense soil complete all as specified and directed by Engineer-in-Charge.
Material and labour for removing excavated surplus hard/dense soil to a distance not exceeding 50 m and depsoiting where directed at a level not exceeding 1.5 m above the starting point complete all as specified and directed by Engineer-in-Charge.
Material and labour for river washed and screened, dry sand for filling in trenches below and around underground cables and in substation ducts for cushioning of cables etc, complete all as specified and directed by Engineer-in-Charge. NOTE :- Measurement should be after punning down
Supply & fixing of sub class B bricks having minimum compressive strength 75 Kg/ Sq cm laid in trenches for cable protection etc complete all as specified and directed by Engineer-in-Charge.
Dismantling concrete poles/ struts incl any size complete all as specified and directed by Engineer-in-Charge.
Re-fixing only of LED Street light retrived from item No-6 complete all as specified and directed by Engineer-in-Charge.
Re-fixing only of KIOSK Box retrived from item No-6 complete all as specified and directed by Engineer-in-Charge.
Supply and laying or fixing or passing through pipe, 1100 volts grade heavy duty cable with PVC insulated aluminium conductor served with an inner sheathing of PVC tape armoured with galvanised steel wire or tape and overall PVC sheathed 6 sq. mm 2 core nominal cross section in service connections complete all as specified and directed by Engineer-in-Charge after removing the old/damage cable.
Supply and laying of XLPE insulated heavy duty electric, un armoured cables 16 sqmm 4 core with aluminium conductor, 1100 volts grade for necessary connection with suitable lugs & fixing arrangement with necessary clamps & cable glands etc complete all as specified and directed by Engineer-in-Charge after removing the old/damaged cable.
Supply & fixing in replacement KIOSK Box weather proof made up of one piece mounted on SMC base and door pole mounted hinged door of size 333 x233x 120 mm outside and 300 x 200 x105 mm inside dimension comprising of aluminum bus bar 4 strips for 3 phase and neutral 63 Amp and 6 Amp fuse grip with base for controlling the steet light fitting and FL clamps 30x4mm with necessary MS nuts bolts and washers and including applying two coasts of synthetic enamel paint over a coat of red oxide zinc chrome primer on new steel surface and including embassing/painting of Danger notice of size not less than 10 cm x 7.5cm with letters, figures and conventional skull and bones in signal red colour on front face of KIOSK box body complete all as specified and directed by Engineer-in-Charge.
Material and labour for boring of hole under road/pavement/hard standing or any other situation by manual means and suitable for passing of GI pipe 100 mm bore and making good both ends complete all as specified and directed by Engineer-in-Charge.
Supply and fixing of 40 mm dia galvanized iron mild steel tubing, light grade including all fitting for cable protection etc laid in floor or fixed to poles with clamps etc complete all as specified and directed by Engineer-in-Charge.
Supply and fixing in replacement LED street light fitting of 60 watt 230 V AC outdoor type with high pressure die cast aluminium hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP65/66 protection complete all as specified and directed by Engineer-in-Charge.
Supply and fixing of New Generation Energy saving LED flood light of 100 watt power coated PDC aluminium body with toughened glass visor. Equipped with secondary optical PC lence Efficacy >110 Lm/w. Available in 5700K CCT, IP66 complete all as specified and directed by Engineer-in-Charge.
Supply and fixing New Generation Energy saving LED flood light of 120 watt power coated PDC aluminium body with toughened glass visor. Equipped with secondary optical PC lence Efficacy >110 Lm/w. Available in 5700K CCT, IP66 complete all as specified and directed by Engineer-in-Charge.
Supply & Fixing of Victoria LED Post Top or equivalent Fitting of 35 Watt, IP-65 protection ,energy saving, long life aesthetically designed with good indirect symmetricl light distribution, single peice pressure die cast aluminium landscapeluminaire with high power COB LED as light source, 220 volt, 50 Hz, high grade powder coated finish with high voltage surge protection device up to 3.0 KV & other safety test as per IS 15885 , with electronic driver, bolts,nuts & washers and suitable for pole complete all as specified and directed by Engineer-in-Charge.
Material and labour for bracket made out of GI pipe 40 mm dia medium grade, 1.2 meter long bent to shape fixed with MS flat irom clamps made out of 40mm x 6 mm thick, nuts bolts complete all as specified and directed by Engineer-in-Charge.
Supply and fixing in renewal of 3 pole power contactor ML-6 mounted on any type/description LT panel/feeder pillar/wall after taking down old existing un serviceable contactor complete all as specified and directed by Engineer-in-Charge.
Supply and fixing in renewal of 3 pole power contactor MNX-110 mounted on any type/description LT panel/feeder pillar/wall after taking down old existing un serviceable contactor complete all as specified and directed by Engineer-in-Charge.
Supply and fixing in renewal of Analog Time switch , 240 Volt AC , 50 Hz , mounted on any type/description LT panel/feeder pillar/wall after taking down old existing un serviceable time switch complete all as specified and directed by Engineer-in-Charge.
Taking down of unsv street light from street light pole and material and labour for fixing in replacement of Driver suitable for LED Street light 45-60 watt, any make complete all as specified and directed by Engr In charge.
Material and labour for prunning/trimming the branches of trees if any along LT overhead line/ street light pole, 3 mtr on all side below/above/sides of LT overhead line and removing the same upto 150 mtr away each span not exceeding 50 mtr complete all as specified and directed by Engineer-in-Charge (NOTE :- The above is to be ensured for the entire contract period by cutting/trimming of trees any number of times as required).
Material and labour for preparation of old painted surfaces of Steel tubular LT poles, any height including cross arms, MS strap, nuts, bolts, washers, cable protection pipe wherever provided etc and painting of complete poles with one coat of aluminium paint from 2.1 m above ground level to top of pole including cross arms and protection pipe and painting of bottom area of pole upto 2.1 m from ground level with synthetic enamel paint in alternate layer (30 cm wide) with black and yellow paint including writing pole numbers in white letter of approved size on black ground complete all as specified and directed by Engineer-in-Charge.
Preparation of old painted surfaces of LT PCC poles for cross arms, MS strap, nuts, bolts, washers, cable protection pipe wherever provided etc and painting with one coat of aluminium paint and painting of bottom area of pole upto 2.1 m from ground level with synthetic enamel paint in alternate layer (30 cm wide) with black and yellow paint including writing pole numbers in white letter of approved size on black ground complete all as specified and directed by Engineer-in-Charge.
Supply and fixing of steel tubular swaged poles type 410 SP-31 (9.0 meter long) Swan Neck Type complete with CI base plate and finial and single swan neck, including painting of complete poles with two coat of aluminium paint from 2.1 m above ground level to top of pole and painting of bottom area of pole upto 2.1 m from ground level with synthetic enamel paint in alternate layer (30 cm wide) with black and yellow paint including protection pipe over a coat of red oxide zinc chrome primer on new steel surface, complete all as specified and directed by Engineer-in-Charge
Supply & Fixing of 3 Mtr long decorative, 02 Nos bracket Pole aesthetically designed decorative hot dipped galvanised mild steel step pole with grey powder finish, Compatible for all Havells/ Bajaj/ Crompton post top range. Window-plasma out cut & duly chamfered opening window of 300 X 110 mm for treminal connection & mounting accessories. Window cover is fitted with allen screws to the pole. Decorative sleek casting ring to increase aesthetical appeal with bolts,nuts & washers including earth work and RCC foundation as per height of light all as specified and directed by Engr-in-charge.
Material and labour for plain cement concrete type D2, 1:4:8 (using 40 mm graded crushed trap stone aggregate) in foundations, filling and mass concrete complete all as specified and directed by Engineer-in-Charge.
Material and labour for plain cement concrete type B1, 1:2:4 (20 mm graded crushed trap stone aggregate) in coping and the like including weathering, slightly rounded or chamfered angles and throating as directed with and including use of form work complete all as specified and directed by Engineer-in-Charge
Material and labour for cement concrete type B-1, 1:2:4, 50 mm thick (using 20 mm gradded aggregate) for floors and paving etc complete all as specified and directed by Engineer-in-Charge
Material and labour for painting of timer panel boards out door/in door of size above 5.00 Sqmm floor/leg mounted installed at different locations including preparation of exposed surface by removing old paint from the body, cleaning the surface with thinner and applying two coats of synthetic enamelled smoke grey paint including repair of panel door's nut & bolts/hinges etc for smooth functioning to open and clsoe of doors complete all as specified and directed by Engineer-in-Charge.
Material and labour for earthing complete with galvanized steel earth plate electrode of size 60cm x 60cm x 6 mm thick, buried directly in ground (earth pit not less than 2.25 m below normal ground level) with top edge of earth plate not less than 1.5m below normal ground level, connected to galvanized strip 32 x 6 mm, by means of bolts, nuts, check nuts and washers of galvanised iron or steel as shown in electrical plate No 3 of SSR Part I, connected to earth test point and the equipment on the other nuts and washers of galvanised ironside complete all as specified, including testing and commissioning complete all as specified and directed by Engineer-in-Charge. Note : (a) The unit rates quoted against this item shall be deemed to include the cost of excavation and earth work in any type of soil, common salt & charcoal dust in alternate layers, PCC 1:3:6 as in pit, precast RCC 1:2:4 type B-1 with necessary reinforcement as in cover & frame for pit, funnel, watering pipe 20 mm bore GI pipe light grade, protection pipe 15 mm bore GI pipe medium grade etc. (b) The quoted rates shall also deemed to include the cost of earth test point and earth strip/GI lead wire and protection pipe upto 7.5 meter beyond the earth plates electrode.
Supply & fixing in replacement of Automatic Transfer Switch (ATS) 4 pole 200 Amps 50 KA with enclosoure, complete internal wiring & taking out old unserviceable ATS from wall & fabrication works for proper fitting complete all as specified and directed by Engineer-in-Charge.
Note : Contractor should procure and provide 50 % of the material as listed above within 15 days of the placing of work order and shall be verified by the Engr-in-charge
KISHORE ENTERPRISES (BID ID -3340780)
Haryana EngineerService (BID ID -3336113)
Rajindera Enterprises (BID ID -3340344)
DS CONSTRUCTION (BID ID -3340643)
SB ENTERPRISES (BID ID -3341251)
mayur enterprises (BID ID -3334348)
MV Engineers And Contractors (BID ID -3337535)
M P TYAGI ENGINEERS AND CONTRACTORS (BID ID -3340668)
Vijay Electricals (BID ID -3341150)
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .