| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹11.6 LAccepted-AOC | L1 | Accepted-AOC Accepted being lowest bidder | |
| 2 | L2₹12.9 L+₹1.3 L (11.1%)Rejected-AOC SHIV BARI ROAD NEAR KASUMAL HOTEL BIKANER 334003 RAJASTHAN | BIKANER | BIKANER | RAJASTHAN | 334003 | L2 | Rejected-AOC Other than lowest bidde | |
| 3 | L3₹13.1 L+₹1.4 L (12.2%)Rejected-AOC WARD NO 40 REGRON KA MOHALLA NEAR RAVI DASS JI MANDIR SHIV BARI BIKANER RAJSTHAN 334001 | BIKANER | RAJASTHAN | 334001 | L3 | Rejected-AOC Other than lowest bidder |
Tender Value
₹12.1 L
EMD Value
₹24,260
Closing Date
27 Nov 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Col Avik Saxena, CWE
HQ CWE Bikaner, Mil Stn Bikaner, PIN-334001
Provn of 09 x 3 Phase connection for certain place at Suratgarh Mil Stn
2021_MES_485594_1
CWE BKN TOKEN NO 60 OF 2021-22
Open Tender
Electrical and Maintenance Works
Item Rate
120 days
Suratgarh
Contractor shall be enlisted with MES in Class E and above and category b ii subject to satisfactory remarks wrt performance in respect of works in hand as reflected in Work Load Return
7 documents required · 7 mandatory
₹500
GE (A) Suratgarh
₹24,260
Yes
22 Dec 2021
1 Nov 2021
29 Nov 2021
1 Nov 2021
27 Nov 2021
15 Nov 2021
1 Nov 2021 - 10 Nov 2021
60 days
Amount
Fixing/shifting only distribution transformer of capacity 160/250 KVA copper wound, step down, outdoor type, 11000/433 Volts, 3 phase, on plinth/four pole structure including connection on both HT & LT sides with cable/conductor/earthing, commissioning and testing of transformer complete all as specified and as directed . Notes : (i) 160/250 KVA, 11000/433 Volts Transformer shall be issued by department under Schedule 'B' free for fixing. (ii) Cost of Shifting of transformer from MES store yard to required location shall deemed to be included in quoted rate of this item.
Supply, laying, jointing and testing HT XLPE (cross linked polyethylene) insulated, screened, PVC bedded, galvanised steel strip or wire armoured electric power cable (heavy duty) (ISI marked) with aluminium stranded conductor 11000 Volt (Earthed) grade of cross sectional area 95 Sqmm, 3 Core laid in trenches/ducts, through pipe, under floors or roads/ along poles etc, and fixing with suitable clamps made of MS flat of size 25mm x 3mm and provision of CI cable route indicators of size 100mm dia, 6mm thickness duly embossed ‘HT’ attached with 45cm long angle iron of size 25x25x5mm fixed along the route of cable at a distance of 40 meter and at turning points, complete all as specified and as directed. Notes :- (i) Sand cushioning, cable protection, GI protection pipe, jointing kits and excavation & earth work shall be measured & paid for separately. (ii) Road cutting/floor cutting /cutting holes etc in walls required for laying/fixing of cable etc shall be made good as per existing. Nothing extra shall be admissible on this account. Quoted rates shall be inclusive of the above provisions.
Supply, laying, jointing and testing LT XLPE (cross linked polyethylene) insulated, screened, PVC bedded, galvanised steel strip or wire armoured electric cable (heavy duty) with aluminium stranded conductor 1100 Volt grade cross sectional area 400 Sqmm 3.5 core (ISI marked) laid in trenches/ducts, through pipe, under floors or roads/ along poles etc and fixing with suitable clamps made of MS flat of size 25mm x 3mm and provision of CI cable route indicators of size 100mm dia, 6mm thickness duly embossed ‘LT’ attached with 45cm long angle iron of size 25x25x5mm fixed along the route of cable at a distance of 40 meter and at turning points, complete all as specified and as directed. Notes :- (i) Sand cushioning, cable protection, GI protection pipe, jointing kits, cable route indicator and excavation & earth work shall be measured & paid for separately. (ii) Road cutting/floor cutting /cutting holes etc in walls required for laying/fixing of cable etc shall be made good as per existing. Nothing extra shall be admissible on this account. Quoted rates shall be inclusive of the above provisions.
All as per serial item No 3.00 here-in-before but of size 185 Sqmm 3.5 Core.
All as per serial item No 3.00 here-in-before but of size 35 Sqmm 3.5 Core.
M&L for cable jointing kit for 11 KV (Earthed) grade cable for outdoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 50 sqmm to 95 sqmm complete all as specified & as directed.
M&L for cable jointing kit for 1100 Volts grade cable for outdoor termination heat shrink type joint complete with jointing material and accessories suitable for 3.5 core XLPE armoured aluminium conductor cable of size 400 sqmm, complete all as specified & as directed.
M&L for cable jointing kit for 1100 Volts grade cable for outdoor termination heat shrink type joint complete with jointing material and accessories suitable for 3.5 core XLPE armoured aluminium conductor cable of size 150 sqmm to 185 sqmm, complete all as specified & as directed.
Excavating in trenches, not exc 1.5 metre wide and not exc 1.5 metre in depth, for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. laying cables, pipes, etc. not exc 10 Sqm on plan & not exc 1.5m in depth and getting out in soft/loose soil complete all as specified and as directed.
Returning, filling in, including spreading, leveling watering and well ramming in layers not exc 25 cm thick in soft/loose soil complete all as specified and as directed.
Removing excavated soil/material to a distance not exc 50 metre and depositing where directed at a level not exc 1.50 metre above the starting point complete all as specified and as directed.
M&L for dry sand (Local Tibba sand) and punning for cushioning and cover for protection of under ground electric cable complete all as specified and as directed. Notes : (i) Approved local Tibba dry sand free from vegetations, grass and other deleterious substances shall be used. (ii) For the purpose of payment, only punned thickness shall be measured.
M&L for sub class ‘B’ (old size) burnt clay bricks laid flat and dry abutting each other with gap between adjacent bricks not exc. 10mm for protection of underground electric cable in such a way that the length of brick is at right angle to the central axis of cable complete all as specified and as directed.
M&L for Galvanized iron tubing, 80mm bore light grade, ISI marked, including all fittings and laid in trenches/under road/drains, fixed to poles/walls with required size of flat iron (25mmx3mm) clamps, bolts, nuts and washers for protection of HT/LT electric cable complete all as specified & as directed. Note :- Excavation & earthwork shall be measured & paid for separately.
S&F Lightning arresters HT 11 KV 65 kilo Amp Non linear expulsion type transmission class with standard fittings confirming to IS-3070 (Part-I) 1985, complete all as specified & as directed.
S&F Switch air break, gang operated outdoor, Horizontal operated type, HT 11 KV, Triple pole, 200 Amps, 3 insulator per phase, tilting/rocking type, with fixed contacts of phosphorous bronze and moving contacts of copper, manually operated from ground level with operating mechanism including GI tubing medium grade 25mm bore operating rod, pad locking arrangements, MS arcing horns, flexible braiding earthing blades, rod and contacts with & including drop out fuse assembly (three numbers each of 40 Amp) and jumpers with Mink conductor line, taps, clamps, colour coated HT sleeves and fittings suitable for horizontal mounting, complete all as specified and as directed.
Supplying, installing, commissioning & testing factory made and tested (CPRI type test certified) LT Panel cubical type (KIOSK) of size as per IS specifications with Automatic Intelligent Power Factor Corrector (AIPFC) Capacitor Bank of capacity 120 KVAR with staging 1+2+3+4+5+5+10+15+15+20+20+20 LT 3 Phase 415 Volt, 3 Phase & neutral, 4 wire, 50 Hz AC supply system to improve power factor 0.80 to 0.98 automatic step wise switched capacitor panel outdoor type, weather proof, dust vermin proof, IP-53, made out of CRCA M.S sheet 3.15 mm thick and detachable plate at bottom for cable entry including double compression type gland etc. factory fabricated as modulate in construction duly powder coated flint grey shade (RAL-7032), front openable double panel shutters with locking arrangement to facilitate easy maintenance, exhaust fan cooled, having cable entry gland, panel shall be mounted on angle iron frame and legs made from angle of size 50x50x5 mm including necessary internal wiring with PVC insulated stranded copper conductor FRLS cables of appropriate size (1.5 / 4 / 6 / 10 sqmm as directed) with proper ferrule & cable glands, including danger notice sticker, comprising & including the following accessories complete all as specified and as directed :- (Contd…)
Description of serial item No. 17.00 contd… (a) 250 Amps aluminium bus bar for phases and Neutral duly insulated with heat shrinkable PVC sleeves and colour coded mounted on heavy duty epoxy insulators in separate compartment and internally prewired - 01 Set (b) MCCB, 250 Amps, 25 KA, 4 Pole, 415 Volt grade, AC, 50 Hz, Thermal - Magnetic release type – 01 No (c) AIPFC micro processor based relay 12 stage - 01 No (d) Capacitor duty Contactors 3 phase suitable for 1, 2, 3, 4, 5, 5, 10, 15, 15, 20, 20, 20 KVAR - 12 Nos (e) MCB 3 Pole 10 KA up to 32 Amps - 12 Nos. (f) Indicator Lamp LED type complete - 12 Nos. (g) Digital Voltmeter 0-500 Volt, AC of size 96mm x 96mm - 01 No (h) Digital Ammeter 0-200 Amp of size 96mm x 96mm - 01 No (j) Current Transformer of ratio 160/5, 15 VA - 04 Nos. (k) 440 Volt 3 Phase Power Capacitors double dielectric heavy duty 1, 2, 3, 4, 5, 5, 10, 15, 15, 20, 20, 20 KVAR - 01 No Each
Notes for serial item No. 17.00 :- (i) Vertical height of legs of LT Panel base frame shall be not less than 45 cm from top of nearest road level / PCC floor finish. Legs shall be grouted upto 30cm in PCC (1:3:6) type C1 (using 20 mm graded crushed stone aggregate). (ii) The contractor shall produce and get the detailed drawings of LT Panel approved from GE before fabrication and placing the order to the approved manufacturer. (iii) The quoted rate shall deemed to include supply & provision of built in flush type locks (with 02 keys) of superior quality as directed by Engineer in Charge. (iv) MS frame work shall be painted with two coats of synthetic enamel paint of approved tint over a coat of red oxide primer. (v) Cost of MS frame work, painting, platform, MCCB spreaders, cable glands, locking arrangement with lock and key and any minor addition/alteration where required at site (the decision of GE will be final and binding regarding extent to which the change can be considered as minor addition/alteration) shall be deemed to be included in the quoted rates.
Supply, installing, testing and commissioning factory made and tested (CPRI type test certified) LT Panel Box cubical type (KIOSK) of size as per IS specifications outdoor type suitable for operation on 415 Volts, 3 Phase & neutral, 4 wire, 50 Hz supply system including bus bar chamber in center (vertically) and cable alley either side, outer shell shall be made out of 3.15mm thick CRCA sheet duly powder coated flint grey shade (RAL-7032) and completely weather, vermin & dust proof, IP-53, adequate air ventilation at sides & back, outer door shall be provided with double door fixed with hinges and locking arrangements etc suitable to accommodate the following mentioned fittings and inner compartments shell shall be made out of 2mm thick CRCA sheet duly powder coated & compartmentalized for each control gear front openable single door with half knob type locking, including provision for taking out incoming and outgoing cables duly marked with riveted letter plated of appropriate size for each feeder / block cable, danger board, detachable plate at bottom for cable entry including double compression type gland etc. with bottom frame & legs made out of angle iron 50mm x 50mm x 5mm and 750mm long 4 legs duly painted with 2 coats of synthetic enamel paint over a coat of red oxide primer on exposed surfaces grouted in PCC 1:2:4 type B1 using 20mm graded stone aggregate blocks of size 30cm x 30cm x 60cm and 100mm thick PCC (1:2:4) type B1 floor over and including 100mm thick sub base of brick hardcore extended 100mm on all sides below panel body including necessary internal wiring with PVC insulated stranded copper conductor FRLS cables of appropriate size (1.5 / 4 / 6 / 10 sqmm as directed) with proper ferrule & cable glands, with and including following accessories complete all as specified and directed :- (contd…)
Description of serial item No. 18.00 contd… Incoming :- (a) 630 Amps Copper bus bar for phases and Neutral duly insulated with heat shrinkable PVC sleeves and colour coded mounted on heavy duty epoxy insulators - 01 Set (b) MCCB, 400 Amps, 36 KA, 4 Pole, Thermal Magnetic release type - 01 No. Outgoing:- (c) MCCB, 400 Amps, 36 KA, 4 Pole, Thermal Magnetic release - 01 No (d) MCCB, 200 Amps, 25 KA, 4 Pole, Thermal Magnetic release - 01 No (e) Digital Voltmeter - 1 No (f) Digital Ammeter - 1 No (g) CTs 200/5 Amps - 01 set (set of three) (h) Indicator Set RYB, “LED” type (set of three) -01 Set
Notes for serial item No. 18.00 :- (i) The contractor shall produce and get the detailed drawings of LT Panel approved from GE before fabrication and placing the order to the approved manufacturer. (ii) The quoted rate shall deemed to include supply & provision of built in flush type locks (with 02 keys) of superior quality as directed by Engineer in Charge. (iii) MS frame work shall be painted with two coats of synthetic enamel paint of approved tint over a coat of red oxide primer. (iv) Cost of MS frame work, painting, platform, MCCB spreaders, cable glands, locking arrangement with lock and key and any minor addition/alteration where required at site (the decision of GE will be final and binding regarding extent to which the change can be considered as minor addition/alteration) shall be deemed to be included in the quoted rates.
Supply, installing, testing and commissioning factory made and tested (CPRI type test certified) LT Panel Box cubical type (KIOSK) of size as per IS specifications outdoor type suitable for operation on 415 Volts, 3 Phase & neutral, 4 wire, 50 Hz supply system including bus bar chamber in center (vertically) and cable alley either side, outer shell shall be made out of 3.15mm thick CRCA sheet duly powder coated flint grey shade (RAL-7032) and completely weather, vermin & dust proof, IP-53, adequate air ventilation at sides & back, outer door shall be provided with double door fixed with hinges and locking arrangements etc suitable to accommodate the following mentioned fittings and inner compartments shell shall be made out of 2mm thick CRCA sheet duly powder coated & compartmentalized for each control gear front openable single door with half knob type locking, including provision for taking out incoming and outgoing cables duly marked with riveted letter plated of appropriate size for each feeder / block cable, danger board, detachable plate at bottom for cable entry including double compression type gland etc. with bottom frame & legs made out of angle iron 50mm x 50mm x 5mm and 750mm long 4 legs duly painted with 2 coats of synthetic enamel paint over a coat of red oxide primer on exposed surfaces grouted in PCC 1:2:4 type B1 using 20mm graded stone aggregate blocks of size 30cm x 30cm x 60cm and 100mm thick PCC (1:2:4) type B1 floor over and including 100mm thick sub base of brick hardcore extended 100mm on all sides below panel body including necessary internal wiring with PVC insulated stranded copper conductor FRLS cables of appropriate size (1.5 / 4 / 6 / 10 sqmm as directed) with proper ferrule & cable glands, with and including following accessories complete all as specified and directed :- (contd…)
Description of serial item No. 19.00 contd… Incoming :- (a) 630 Amps Copper bus bar for phases and Neutral duly insulated with heat shrinkable PVC sleeves and colour coded mounted on heavy duty epoxy insulators - 01 Set (b) MCCB, 400 Amps, 36 KA, 4 Pole, Thermal Magnetic release type - 01 No. Outgoing:- (c) MCCB, 250 Amps, 36 KA, 4 Pole, Thermal Magnetic release - 01 No (d) MCCB, 63 Amps, 25 KA, 4 Pole, Thermal Magnetic release - 04 Nos (e) Digital Voltmeter - 1 No (f) Digital Ammeter - 1 No (g) CTs 200/5 Amps - 01 set (set of three) (h) Indicator Set RYB, “LED” type (set of three) -01 Set
Notes for serial item No. 19.00 :- (i) The contractor shall produce and get the detailed drawings of LT Panel approved from GE before fabrication and placing the order to the approved manufacturer. (ii) The quoted rate shall deemed to include supply & provision of built in flush type locks (with 02 keys) of superior quality as directed by Engineer in Charge. (iii) MS frame work shall be painted with two coats of synthetic enamel paint of approved tint over a coat of red oxide primer. (iv) Cost of MS frame work, painting, platform, MCCB spreaders, cable glands, locking arrangement with lock and key and any minor addition/alteration where required at site (the decision of GE will be final and binding regarding extent to which the change can be considered as minor addition/alteration) shall be deemed to be included in the quoted rates.
Supply, installing, testing and commissioning factory made and tested (CPRI type test certified) LT Panel Box cubical type (KIOSK) of size as per IS specifications outdoor type suitable for operation on 415 Volts, 3 Phase & neutral, 4 wire, 50 Hz supply system including bus bar chamber in center (vertically) and cable alley either side, outer shell shall be made out of 3.15mm thick CRCA sheet duly powder coated flint grey shade (RAL-7032) and completely weather, vermin & dust proof, IP-53, adequate air ventilation at sides & back, outer door shall be provided with double door fixed with hinges and locking arrangements etc suitable to accommodate the following mentioned fittings and inner compartments shell shall be made out of 2mm thick CRCA sheet duly powder coated & compartmentalized for each control gear front openable single door with half knob type locking, including provision for taking out incoming and outgoing cables duly marked with riveted letter plated of appropriate size for each feeder / block cable, danger board, detachable plate at bottom for cable entry including double compression type gland etc. with bottom frame & legs made out of angle iron 50mm x 50mm x 5mm and 750mm long 4 legs duly painted with 2 coats of synthetic enamel paint over a coat of red oxide primer on exposed surfaces grouted in PCC 1:2:4 type B1 using 20mm graded stone aggregate blocks of size 30cm x 30cm x 60cm and 100mm thick PCC (1:2:4) type B1 floor over and including 100mm thick sub base of brick hardcore extended 100mm on all sides below panel body including necessary internal wiring with PVC insulated stranded copper conductor FRLS cables of appropriate size (1.5 / 4 / 6 / 10 sqmm as directed) with proper ferrule & cable glands, with and including following accessories complete all as specified and directed :- (contd…)
Description of serial item No. 20.00 contd… Incoming :- (a) 400 Amps Copper bus bar for phases and Neutral duly insulated with heat shrinkable PVC sleeves and colour coded mounted on heavy duty epoxy insulators - 01 Set (b) MCCB, 250 Amps, 36 KA, 4 Pole, Thermal Magnetic release type - 01 No. Outgoing:- (c) MCCB, 63 Amps, 25 KA, 4 Pole, Thermal Magnetic release - 05 Nos (d) Digital Voltmeter - 1 No (e) Digital Ammeter - 1 No (f) CTs 200/5 Amps - 01 set (set of three) (g) Indicator Set RYB, “LED” type (set of three) -01 Set
Notes for serial item No. 20.00 :- (i) The contractor shall produce and get the detailed drawings of LT Panel approved from GE before fabrication and placing the order to the approved manufacturer. (ii) The quoted rate shall deemed to include supply & provision of built in flush type locks (with 02 keys) of superior quality as directed by Engineer in Charge. (iii) MS frame work shall be painted with two coats of synthetic enamel paint of approved tint over a coat of red oxide primer. (iv) Cost of MS frame work, painting, platform, MCCB spreaders, cable glands, locking arrangement with lock and key and any minor addition/alteration where required at site (the decision of GE will be final and binding regarding extent to which the change can be considered as minor addition/alteration) shall be deemed to be included in the quoted rates.
Material and labour for brick masonry platform with RCC slab (for transformer etc) with dimensions 2.00m x 2.00m at top, 120cm height above GL and 70cm deep foundation and shall be constructed as per following details, complete all as specified and as directed :- (a) Below Ground Level (GL) :- (i) Excavation and earthwork shall be in any type of soil and surplus excavated material shall be removed up to a distance exc 200m but not exc 250m. The total depth of foundation shall be 70cm below GL. (ii) Concrete bed for brick work wall in foundation shall be of uniform thickness of 10cm and 80cm breadth with PCC (1:4:8) type D2 using 40mm graded crushed stone aggregate. (iii) Brick work wall footing 1st course i.e bottom course all around shall be 30cm deep & 69cm breadth built in cement mortar (1:4) using old size fly ash bricks. (iv) Brick work wall footing 2nd course all around shall be 30cm deep & 57.5cm breadth built in cement mortar (1:4) using old size fly ash bricks. (b) Above Ground Level :- (i) Brick work wall above GL all around shall be of 75cm height & 46cm thickness built in cement mortar (1:4) using old size fly ash bricks. (ii) 100mm thick PCC (1:2:4) type B1 using 20mm graded crushed stone aggregate shall be provided on top of wall in full width. (iii) 150mm thick RCC slab on top with cement concrete (1:2:4) type B1 using 20mm graded crushed stone aggregate with reinforcement of 12mm dia TMT bars @ 100mm C/C both ways shall be provided using proper formwork. (iv) External surfaces of brick work & concrete above plinth protection shall be plastered with 15mm thick plaster in cement and sand mortar (1:4) finished fair & even. Plaster on top of RCC slab shall not be provided. (v) Three coats of white wash shall be provided on all plastered surfaces. (vi) 75mm thick PCC 1:3:6 type C1 using 20 mm graded crushed stone aggregate as in plinth protection of 75cm width with surface finished even and smooth without using extra cement shall be provided all around the platform walls. (vii) Hollow portion of platform above GL & below RCC slab shall be filled with 40mm to 63mm crushed stone aggregate & compacted by using local dry tibba sand for filling of voids in aggregate.
S&F cross arms, bracing, supports, clamps and back plates fabricated from structural steel sections conforming to Grade E-165 (Fe 290) including nuts, bolts, washers, welding, bending cold or hot, drilled holes for bolts, in any shape or size with & including two coats of aluminium paint over a coat of red oxide zinc chrome primer, complete all as specified & as directed. Notes :- (i) Size, section and shape of steel sections shall be as directed. (ii) Weight of paint shall not be considered for payment purpose and quoted rate shall deemed to be included this aspect.
S&F Aluminium Conductor Steel Reinforced (ACSR) of any size as directed, stringing for overhead line on HT/LT poles including jointing with and including aluminium binding wire 2 mm dia, jumpers, line tapes, conducting jelly, stretching properly and connecting with suitable PG clamps, complete all as specified and as directed. Notes : (i) The ACSR conductors shall conforming to IS-398 (Part-II) and as specified in SSR Part-I. (ii) The unit rate quoted shall also deemed to include for supply and fixing of binding wire, aluminium tapes, etc which shall not be included in the weight of conductors for payment. (iii) Weight of conductors shall be determined by measuring the horizontal distance between centers of two adjacent poles and compounding the weight of conductors of that size and length and 3% extra shall be added for sag, jointing, jumpers etc. (iv) Weight of the conductors shall be calculated from the nominal weights given in tables in the relevant IS code.
S&F Pin/Post type insulator, porcelain, vitreous, white, brown or green for working pressure 11000 Volts, 150mm height and 150mm dia including galvanized mild steel spindle, two Nos GI washers, one No GI nut, complete all as specified & as directed.
S&F Disc type insulator, porcelain, vitreous, 145mm high and 255mm dia ball and socket type, white, brown or green, single disc assembly for tension with tension clamps for conductors, working pressure 11000 Volts, complete all as specified & as directed.
M&L for Earthing to Panel / Transformer / GOD switch / equipments etc with & including galvanised mild steel earth plate electrode of size 60 cm x 60 cm x 6 mm thick buried vertically in ground (earth pit not less than 2.25 m below normal ground level) with top edge of the earth plate at a depth not less than 1.5 m below ground level, the earth electrode surrounded by adequate quantity of charcoal dust and salt to a packed thickness of 15 cm on all sides, connected to & including galvanized mild steel strip 32x6 mm as earth lead, including nuts, bolts, check nuts & washers of galvanized iron or steel and riveted/welded to earth plate at one end and other end of strip connected to Panel / transformer / GOD / equipment body / test point with two Nos nuts bolts or welding with steel structure, GI earth strip encased in and including 40mm bore GI light grade pipe with all fittings from upper edges of earth plate upto 7.5 metre above ground level fixed with and including 25x3mm flat iron clamps, bolts, nuts and washer and also including providing watering pipe 20mm bore GI pipe medium grade from earth pit to top of electrode and including funnel, wire mesh, copper lugs etc complete with earth pit in PCC 1:3:6 type C1 using 20mm graded crushed stone aggregate and 40mm thick RCC (1:2:4 type B1) cover complete all as specified and shown in electrical plate No 3 of SSR Part-I including necessary excavation and earthwork in any type of soil, returning, filling in approved soil and disposal of surplus soil to a distance not exc 50m complete all as specified and as directed. Note : PCC chamber shall be constructed at least 1.5 mtr away from the earth electrode and pipe for watering shall be provided in slanting manner.
M/s Rohit Construction Co.
B.K. ROY & SONS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .