Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹32.1 LAccepted-AOC STREET NO 11 SECTOR NO 04 TILAK NAGAR SAGAR ROAD BIKANER RAJASTHAN 334001 | BIKANER | RAJASTHAN | 334001 | 1 | Accepted-AOC Being lowest | |
| 2 | 2₹40.7 L+₹7.1 L (21.3%)Rejected-Finance 43 VIMAL ENCLAVE CHAMRAULI MODE SHAMSHABAD ROAD AGRA UP 282001 | AGRA | AGRA | UTTAR PRADESH | 282001 | 2 | Rejected-Finance Not being lowest | |
| 3 | 3₹43.7 L+₹10.2 L (30.5%)Rejected-Finance | 3 | Rejected-Finance Not being lowest | |
| 4 | 4₹44.7 L+₹11.2 L (33.3%)Rejected-Finance | 4 | Rejected-Finance Not being lowest | |
| 5 | 5₹64.8 L+₹31.3 L (93.5%)Rejected-Finance | 5 | Rejected-Finance Not being lowest |
| Sl No | Description | Qty | Unit | AIRCOM L5 | BRITE INDUSTRIES L4 | M/S J J ENTERPRISES L3 | YAUK ENGINEERS L1 | S S TRADERS L2 |
|---|---|---|---|---|---|---|---|---|
| 1.00 | Checking/ detecting and arresting/rectifiying of the leakage by putting nitrogen and oxygen gas in central type AC system comprising of compressor, condensor unit, gas piping system and AHU complete cycle system of capacity upto 13 TR, and material & labour for repairing the leakage if detected, vaccum & checking for vaccum pressure holding stand for 24 hrs and charging the refrigerant gas (M-22) as required and top up of compressor oil if required of complete all as specified and directed of .following capacity:
Note:- 1.Refrigerant gas (M-22) and compressor oil shall be measured and paid seprately under respactive item herein after. 2. AC Complaint will attend in 24 hours otherwise penalty of Rs 1000 will be charged | - | - | - | - | - | - | - |
| 1.01 | capacity 21 to 26 TR | 3 | Each Job | 2,000 ₹6,000 | 3,000 ₹9,000 | 1,200 ₹3,600 Lowest | 2,000 ₹6,000 | 2,800 ₹8,400 |
| 1.02 | capacity 15 to 20 TR | 3 | Each Job | 2,000 ₹6,000 | 2,500 ₹7,500 | 1,200 ₹3,600 Lowest | 2,000 ₹6,000 | 2,800 ₹8,400 |
| 1.03 | capacity 11 to 13 TR | 6 | Each Job | 2,000 ₹12,000 | 2,500 ₹15,000 | 1,200 ₹7,200 Lowest | 2,000 ₹12,000 | 2,800 ₹16,800 |
| 1.04 | Capacity 09 to 10 TR | 3 | Each Job | 2,000 ₹6,000 | 2,500 ₹7,500 | 1,200 ₹3,600 Lowest | 2,000 ₹6,000 | 2,800 ₹8,400 |
| 2.00 | Labour only for servicing / repairing of package type central AC plant unit ( out door and Indoor unit, AHU) where required in ACs or as directed by Engr-in-Charge Or concern JE at site of COD to attend and rectfy the defects by settings of controls or by repair/ replacement work to air conditioning plant unit/ system etc as per standard engineering practice,along with all necessary tools etc and keeping proper record of maintenance record in register supplied by the contractor). | 106 | Each Job | 500 ₹53,000 Lowest | 500 ₹53,000 Lowest | 1,500 ₹1,59,000 | 800 ₹84,800 | 1,000 ₹1,06,000 |
| 2.01 | Notes:- (i) Spare parts required for repair/ rectification of defects shall be mesured and paid saperatly under respactive items here in after.
(ii) Contractor will ensure proper functioning of All AC plants at all workig days times.
(iii) Repair work of plant shall be carried out by well experienced technitions/ mechanic who has experienced/ working certificate form OEM with proper tools and safety measures.
(iv) All petty small parts required for repair i.e. nuts, bolts, washers screws, saddles, grease, oil/ lubricants etc shall be provided by the contractor without any extra cost to the government.
(vi) Complaint Register andcomplaint Job Card will be provided by contractor and same will be sign by JE/AGE E/M alongwith Location and place of complaints as per requirement of maintenance work of bldg in different areas under GE (W) Agra as directed. (vii) Contractor shall be responsible to provide conveyence and required T&P for attend the complaints.
(viii) Contractor shall be responsible for arrenging security passes from the concern department through there guidlines/ procesure (ix) AC plant Complaint will be rectified with in 24 hours otherwise Rs 1000 penality will be charged for every 8 hours | - | - | - | - | - | - | - |
| 3.00 | Cleaning all filters of AHUs (Indoor units) alongwith its out door unit condensing coil of COD Adm Bldg, EDW, P-3 shed, medical store and medical ward, cleaning the filters with the help of blower & water pressure pump, suitable cleaning materials and washing with clean water to remove the complete dust particles and refixing the same to its original position including checking of tightness of all the nuts & bolts of out door units and combing of bend fins of out door units complete as directed.
Note: All filters and outdoor units shall be cleaned fortnightly basis upto completion of the work. | 95 | Each Unit | 500 ₹47,500 | 500 ₹47,500 | 100 ₹9,500 Lowest | 200 ₹19,000 | 350 ₹33,250 |
| 4.00 | Checking/ detecting and arresting/rectifiying of the leakage by putting nitrogen gas pressure to entire system and rectifying the leakage where found by welding/ brazing/ soldering with copper electrode rod and holding nitrogen pressure in entire system for minimum 08 Hrs in package type AC units , having compressor's capacity 11.0 TR and material & labour for repairing the leakage if detected, vaccum & checking for vaccum pressure holding stand for 24 hrs and charging the refrigerant gas (M-22) as required and top up of compressor oil if required complete all as specified and directed. | 25 | Each Job | 2,000 ₹50,000 | 1,000 ₹25,000 | 850 ₹21,250 Lowest | 1,000 ₹25,000 | 8,000 ₹2,00,000 |
| 5.00 | Checking/ detecting and arresting/rectifiying of the leakage by putting nitrogen gas pressure to entire system and rectifying the leakage where found by welding/ brazing/ soldering with copper electrode rod and holding nitrogen pressure in entire system for minimum 08 Hrs in package type AC units, Model No. DPUASC 875, having compressor's capacity 1x8.75 TR and material & labour for repairing the leakage if detected, vaccum and charging the refrigerant gas (M-22) as required and top up of compressor oil if required complete all as specified and directed. | 5 | Each Job | 2,200 ₹11,000 | 1,000 ₹5,000 | 850 ₹4,250 Lowest | 1,000 ₹5,000 | 1,500 ₹7,500 |
Tender Value
₹61.0 L
EMD Value
₹1.2 L
Closing Date
16 Oct 2025, 6:00 pmClosed
HQ CWE Agra
112, Taj Road, Agra
REPAIR / MAINT OF CENTRAL AC PLANT, CERTAIN PACKAGE TYPE AC AND BLOWER ALONGWITH ALLIED WORKS UNDER AGE E/M OF GE (WEST) AGRA
2025_MES_731578_1
84397
Open Tender
Miscellaneous Works
Item Rate
180 days
Agra
MES contractors enlisted for Class C and above and category c(i) for unenlisted contractors meeting the enlistment criteria corresponding to value class and category of work
8 documents required · 8 mandatory
₹1,000
GE West Agra
₹1.2 L
6 Dec 2025
18 Sept 2025
23 Oct 2025
18 Sept 2025
16 Oct 2025
2 Oct 2025
18 Sept 2025 - 25 Sept 2025
Amount
Checking/ detecting and arresting/rectifiying of the leakage by putting nitrogen and oxygen gas in central type AC system comprising of compressor, condensor unit, gas piping system and AHU complete cycle system of capacity upto 13 TR, and material & labour for repairing the leakage if detected, vaccum & checking for vaccum pressure holding stand for 24 hrs and charging the refrigerant gas (M-22) as required and top up of compressor oil if required of complete all as specified and directed of .following capacity: Note:- 1.Refrigerant gas (M-22) and compressor oil shall be measured and paid seprately under respactive item herein after. 2. AC Complaint will attend in 24 hours otherwise penalty of Rs 1000 will be charged
capacity 21 to 26 TR
capacity 15 to 20 TR
capacity 11 to 13 TR
Capacity 09 to 10 TR
Labour only for servicing / repairing of package type central AC plant unit ( out door and Indoor unit, AHU) where required in ACs or as directed by Engr-in-Charge Or concern JE at site of COD to attend and rectfy the defects by settings of controls or by repair/ replacement work to air conditioning plant unit/ system etc as per standard engineering practice,along with all necessary tools etc and keeping proper record of maintenance record in register supplied by the contractor).
Notes:- (i) Spare parts required for repair/ rectification of defects shall be mesured and paid saperatly under respactive items here in after. (ii) Contractor will ensure proper functioning of All AC plants at all workig days times. (iii) Repair work of plant shall be carried out by well experienced technitions/ mechanic who has experienced/ working certificate form OEM with proper tools and safety measures. (iv) All petty small parts required for repair i.e. nuts, bolts, washers screws, saddles, grease, oil/ lubricants etc shall be provided by the contractor without any extra cost to the government. (vi) Complaint Register andcomplaint Job Card will be provided by contractor and same will be sign by JE/AGE E/M alongwith Location and place of complaints as per requirement of maintenance work of bldg in different areas under GE (W) Agra as directed. (vii) Contractor shall be responsible to provide conveyence and required T&P for attend the complaints. (viii) Contractor shall be responsible for arrenging security passes from the concern department through there guidlines/ procesure (ix) AC plant Complaint will be rectified with in 24 hours otherwise Rs 1000 penality will be charged for every 8 hours
Cleaning all filters of AHUs (Indoor units) alongwith its out door unit condensing coil of COD Adm Bldg, EDW, P-3 shed, medical store and medical ward, cleaning the filters with the help of blower & water pressure pump, suitable cleaning materials and washing with clean water to remove the complete dust particles and refixing the same to its original position including checking of tightness of all the nuts & bolts of out door units and combing of bend fins of out door units complete as directed. Note: All filters and outdoor units shall be cleaned fortnightly basis upto completion of the work.
Checking/ detecting and arresting/rectifiying of the leakage by putting nitrogen gas pressure to entire system and rectifying the leakage where found by welding/ brazing/ soldering with copper electrode rod and holding nitrogen pressure in entire system for minimum 08 Hrs in package type AC units , having compressor's capacity 11.0 TR and material & labour for repairing the leakage if detected, vaccum & checking for vaccum pressure holding stand for 24 hrs and charging the refrigerant gas (M-22) as required and top up of compressor oil if required complete all as specified and directed.
Checking/ detecting and arresting/rectifiying of the leakage by putting nitrogen gas pressure to entire system and rectifying the leakage where found by welding/ brazing/ soldering with copper electrode rod and holding nitrogen pressure in entire system for minimum 08 Hrs in package type AC units, Model No. DPUASC 875, having compressor's capacity 1x8.75 TR and material & labour for repairing the leakage if detected, vaccum and charging the refrigerant gas (M-22) as required and top up of compressor oil if required complete all as specified and directed.
Checking/ detecting and arresting/rectifiying of the leakage by putting nitrogen gas pressure to entire system and rectifying the leakage where found by welding/ brazing/ soldering with copper electrode rod and holding nitrogen pressure in entire system for minimum 08 Hrs in package type AC units,Model No. DPUASC 550, having compressor's capacity 1x5.50 TR and material & labour for repairing the leakage if detected, vaccum and charging the refrigerant gas (M-22) as required and top up of compressor oil if required complete all as specified and directed. Note for item Nos. 4, 5 & 6 :- Refrigerant gas (M-22) and compressor oil shall be measured and paid saperatly under respactive item here-in-after.
M&L for disconnecting, taking out/ down, dismantling, loading/unloading, transporting form site to trade workshop and back after repair of electric motor, including strip opening & taking out the old worn out/unserviceable winding wire and rewinding the electric motor/mono-block with superior quality copper winding wire of suitable size including insulating material (PVC insulation sleeve, tape, film paper, varnish, cotton) required and re-fixing in position and testing complete all as specified & directed of Capacity upto 5 HP
M&L for taking out the mono-block pump 5 HP shaft, remetalling, welding, turning and fixing new bush and sleeve and re-fixing in position complete all as specified and directed.
S&F in replacement ball bearing double coller type complete all as specified and directed for following capacities of electric motor/mono block motor of capacity upto 5 HP
S&F in replacement dial type water pressure gauge 4'' dia of working pressure 5 Kg/Sqcm complete with adopter complete all as specified and directed.
supply & fix in replacement the new sealed compressor of Central type ACs of capacity 11 TR with and including anti vibration pad complete and repairing the leakage if detected after fixing/ fitting the compressor, vaccum and charging the refrigerant gas as required and top up of compressor oil if required and testing on completion complete all as specified and directed. Notes : (i) Refrigerant gas and compressor oil shall be measured and paid saperatly under respactive item after for filling/topping up only (ii) Contractor shall submit the manufacturer test certificate of compressor.
Supply & fix in replacement the new sealed compressor of package type ACs of capacity 11.0 TR with and including anti vibration pad complete and repairing the leakage if detected after fixing/ fitting the compressor, vaccum and charging the refrigerant gas (R-22) as required and top up of compressor oil if required and testing on completion complete all as specified and directed. Make:- Danfoss Model No. SM 147 A4NLB or equivalent model of make Emerson/ Voltas as approved by GE.
supply & fix in replacement the new sealed compressor of package type ACs of capacity 8.75 TR with and including anti vibration pad complete and repairing the leakage if detected after fixing/ fitting the compressor, vaccum and charging the refrigerant gas (R-22) as required and top up of compressor oil if required and testing on completion complete all as specified and directed. Make:- Danfoss Model No. SM 110 S4EA or equivalent model of make Emerson/ Voltas as approved by GE.
supply & fix in replacement the new sealed compressor of package type ACs of capacity 5.50 TR with and including anti vibration pad complete and repairing the leakage if detected after fixing/ fitting the compressor, vaccum and charging the refrigerant gas (R-22) as required and top up of compressor oil if required and testing on completion complete all as specified and directed. Make:- Danfoss Model No. HLM 072 T4LC6 or equivalent model of make Emerson/ Voltas as approved by GE. Notes for item Nos. 12, 13 & 14 :- (i) Refrigerant gas (R-22) and compressor oil shall be measured and paid saperatly under respactive item after for filling/topping up only (ii) Contractor shall submit the manufacturer test certificate of compressor with warranty card alongwith purchase vouchers to Engr-in-Charge for their verification and kept on record.
Repair of LT electric control panel board, cleaning inside with blower, servicing tightening all electrical connections/ contacts points, replacing defective locking clips thimble and making it serviceable with inter locking wiring including replacement of the defective parts and refixing back in its existing position complete all as specified and directed. Note : Defective parts will be measured and paid separately as supply only.
Supply only the following parts of panel board to be fixed under respective items here in above or before complete all as specified and directed:-
(a) Electronic timers type ET-100, 110 V to 240 V, 50 Hz, 3 Sec to 10 Sec.
(b) Electronic timers type ET-100, 110 V to 240 V, 50 Hz, 9 Sec to 30 Sec.
(c) Contactor ML 1.5, Range: 25 A, AC-3 3 pole
(d) Contactor ML 2 Range: 32 A, AC-3, 3 pole
(e) Contactor ML 3 Range: 40 A, AC-3 3 pole
(f) Power contactor ML 4 Range: 70 A, AC-1 • Conforms to IS / IEC 60947-4-1 4 pole
(g) Biametalic over load relay ML type 9 to 14 Amps
(h) Biametalic over load relay ML type 20 to 32 Amps
(j) Biametalic over load relay ML type 28 to 48 Amps
(k) Volt meter 0-500V make : AE (Digital type)
(l) Ampere meter CT type of ratio 5/100 Amp any range
(m) PVC insulated stranded single core copper conductor cable 1100 Volts grade of size 10 Sqmm
(n) PVC insulated stranded single core copper conductor cable 1100 Volts grade of size 16 Sqmm
(o) connector 4 pole, 20 to 40 Amp, 240 volts complete all as specified and directed.
supply & fix in replacement, heating element, 3KW, 240 volts, ISI marked suitable for central/package type plant complete all as specified and directed.
supply & fix in replacement, heating element, 2KW, 240 volts, ISI marked suitable for central/package type plant complete all as specified and directed.
Dismantling air filter section any size of air handling unit and M&L for overhauling/servicing of AHU by cleaning the AHU complete, cooling coil with coil shine, by spraying the dust removal chemical on the fins of coil and let the chemical remains on the fins for 04 hours then clean the chemical with fresh water till the chemical flushes out entirely by pressure of water & wash completly including stoppage of air leakage by using gasket clothing and PGI sheet with nut , bolts and cleaning air handling room with bleaching powder solution/chemical/acid & cleaning of air filter wire mesh/5 micron filter with above solution complete all as specified and directed.
S&F in replacement of fan belts for AHU/ blower unit any capacity complete all as specified and directed :-
S&F in replacement to old existing safety release valve comprising for renewal of Teflon sheet and adjustment of valve for AC plant of any capacity complete all as specified and directed.
S & F in replacement three phase motor connection plate suitable for 3 HP to 5 HP complete all as specified and directed.
S & F in replacement three phase motor connector plate suitable for 12.5 HP to 30 HP complete all as specified and directed.
Supply and fix in replacement water spray header, suitable for 9.5 TR capacity AC plant and connected items etc. complete and necessary water pipe lines connection, commissioning and testing complete all as specified and directed.
Supply and fix in replacement water spray header, suitable for 12.5 TR capacity AC plant and connected items etc. complete and necessary water pipe lines connection, commissioning and testing complete all as specified and directed.
Supply and fix in replacement water spray header, suitable for 20 TR capacity AC plant and connected items etc. complete and necessary water pipe lines connection, commissioning and testing complete all as specified and directed.
Supply and fix in replacement PVC fills of size 300x300x150 mm complete all as specified and directed.
S & F in replacement solenoid coil (for any size of solenoid valve or loader- unloader) and making necessary electric connection complete all as specified and directed
S&F in replacement thermostatic expansion valve flange type of size suitable for 9.5 TR (R-22) AC plant as per and making necessary connection complete all as specified and directed.
S&F in replacement thermostatic expansion valve flange type of size suitable for 12.5 TR AC plant and making necessary connection complete all as specified and directed.
S&F in replacement thermostatic expansion valve flange type of size suitable for 21 TR AC plant as per and making necessary connection complete all as specified and directed.
S&F in replacement thermostatic expansion valve flange type of size suitable for 26 TR AC plant as per and making necessary connection complete all as specified and directed.
supply & fix in replacement, thermostatic expansion valves suitable for 1x11 TR package type AC unit, working temp 110 centigrade and maximum operating pressure 68 PSI complete all as specified and directed.
supply & fix in replacement,, thermostatic expansion valves suitable for 1x8.75 TR package type AC unit, working temp 110 centigrade and maximum operating pressure 68 PSI complete all as specified and directed.
supply & fix in replacement, thermostatic expansion valves suitable for 1x5.50 TR package type AC unit, working temp 110 centigrade and maximum operating pressure 68 PSI complete all as specified and directed.
Supply and fixing in replacement PVC water protection cover /jali for protection from birds, leaf etc to cooling tower tank.
M& L for installing, commissioning & testing of the filter section consists of pre-filter should be made of 14 gauge stainless steel to remove 99.90% of dust, pollen, mold, bacteria and any airborne particles with a size 0.1 micrometer at 85 liters per minute, 90% efficiency complete of size 60 x 60 cm all as specified and directed.
Supply & charging refrigerant gas M-22 in cylinders of required capacity including transportation, loading and unloading charges for collection of empty cylinders from MES store yard of AGE E/M, returning the same cylinder or other cylinder after refilling and testing of cylinders including test certificate by authorised agencies complete all as specified and directed.
Supply & filling non freezing compressor oil in sealed standard sized containers complete all as specified and directed.
M &L for spray painting of 9.5 TR to 23 TR compressor -03 Nos, 12.5 HP to 30 HP electric motor- 03 Nos, 3 HP to 7.5 HP Monoblock pump - 02 Nos and GI Tubing 100 mm dia -15 RM, Cooling tower - 01 No outer body of complete AC Plant by applying one coat of synthetic enamel grey/green paint over the existing paint including cleaning and preparation of surface complete all as specified & directed.
De-scaling the entire water circulation system of AC Plant including condenser but excluding mono block pump set from existing AC plants by circulating de scaling solution with the help of de -scaling pump circulating acid independently in each tube by gravity cleaning the condenser tubing with brush including renewal of worn out gasket, nuts and bolts complete all as specified and directed of following size:-
capacity 21 to 26 TR
capacity 15 to 20 TR
capacity 11 to 13 TR
Capacity 09 to 10 TR
supply & fix in replacement, PMN MPD type microprocessor based controller card (sensor, display card, MPD & relay card) having range 15 to 60 Amps suitable for 26 TR package type AC units complete all as specified and directed.
supply & fix in replacement, PMN MPD type microprocessor based controller card (sensor, display card, MPD & relay card) having range 11 to 35 Amps suitable for 2X11 TR package type AC units complete all as specified and directed.
supply & fix in replacement, PMN MPD type microprocessor based controller card (sensor, display card, MPD & relay card) having range 7 to 22 Amps suitable for 1X8.75 TR package type AC units complete all as specified and directed.
supply & fix in replacement, PMN MPD type microprocessor based controller card (sensor, display card, MPD & relay card) having range 7 to 22 Amps suitable for 2X5.50 TR package type AC units complete all as specified and directed.
Supply and fixed in replacement, air break (power) contactor 3 TF30 0-32 Amp 415volt complete all as specified and directed.
supply & fix in replacement, contactor suitable for blower motor of capacity 7.5HP complete all as specified and directed.
supply & fix in replacement, power contactor suitable for compressor motor of capacity 11 TR Plant complete all as specified and directed.
supply & fix in replacement, power contactor suitable for compressor motor of capacity 8.75 TR Plant complete all as specified and directed.
supply & fix in replacement, power contactor suitable for compressor motor of capacity 5.5 TR Plant complete all as specified and directed.
Supply and fixed in replacement, air break (power) contactor 3 TF30 0-10 Amp 415 volt complete all as specified and directed.
Supply and fixed in replacement, HRC catridge fuse 20 Amp, (IS9224) complete all as specified and directed.
Supply and fixed in replacement, HRC catridge fuse 63 Amp, AC complete all as specified and directed.
S&F in replacement water flow control switch suitable for fixing on chilled water type central AC plant condensor/chilller pipe line,suitable for max pressure 10 bar, model HFS-25, Make Synergy or eqivalant as approved by GE complete all as specified and directed.
Supply & fixing duly fabricated with 0.63 mm thick PGI sheets Hepa Filter Cabinet to be installed in existing supply duct of suitable sizes including installing hepa filters against respective item here-in-after complete all as specified and directed.
Supply and fix in repair cfm meter for observing the temprature of plant all as directed at site
Supply & fixing, commissioning & testing of Y Strainers of size 80mm complete all as specified & directed
Supply & fixing, commissioning & testing of Y Strainers of size 100mm complete all as specified & directed
Supplying & Fixing of GI cable tray of size 300 mm fabricated from - 14 SWG GI Sheet (Without Cover) suiatble for laying/ fixing of electric power cables including necessary structural steel frame support/ brassing to the existing plant room from main electric panel to all machine/ equipments complete all as specified & directed .
S&F copper tubing with PUF (Poly Urethene Foam) insulation 16mm thick of size 5"/8"
S&F PVC flexible drain pipe heavy duty of size 15mm bore
Triming of trees,cutting of herbs and shrubs upto ground level,Cleaning of equipment by cotton waste and removing plants and other garbage material from Installation to nearest garbage bin not more than 2 km from site and cleaning of internal road/path all as directed at site by Engr-in-Charge.
Supply and fix in repair AMF LT Panel 3 phase 4 wire outdoor type, weather proof made out of 2mm thick MS sheet duly powder coated internally / externally with sufficient working space, mounted on the angle iron frame 40 x 40 x 6mm, fixed in the PCC 1:2:4 not less than 500mm above the ground level, connection of all incoming cables / out going cable with the thimbles / lugs / cable glands etc., opening at both side i.e. front / back, locking arrangemnts, Copper bus bar 40 X 8 mm size, , all the accesories pre connected with suitable size Copper bus bar / single core copper conductor comprising of the following all as specified & directed. (a). MCCB 3 Pole, 415 V, Adjustable type, 160 Amps with breaking capacity 25 KA - 01Nos (b). Industrial power contactor 160 Amp 3 pole 3 phase 415 bolt suitable for AMF Panel -02 Nos (c). 4 pole AMF Relay of micro controlled based secondary current input of range upto 160 Amps. (d). LED based indicator lamp sets comprising of three colours - 02 sets. (e). Voltmeter 0 - 500 Volts, Digital display, flush mounted 96mm square 3 phase 4 wire with slector switch - 01 set. (f). Ammeter 0 - 400 Amps, Digital display, flush mounted 96mm square 3 phase 4 wire with slector switch including CTs of required capacity - 06 sets. (g) By pass control switch of suitable size (h) PCC 1:2:4 for grouting of LT Outdoor panel
M&L for PVC Rotational moulded water storage double layered ISI ingraved tanks of capacity 1000 Liters including inlet & outlet connection and float valve (cylindrical vertical with closed top) hoisted on and including RCC slab and brick work staging upto suiatble height for cooling tower complete all as specified and directed.
Supply and installation of refrigerant piping system fabricated with suitable size copper pipe line work with liquid and gas control valve, liquid flow indication valve, thermometer bent, including 19 mm thick closed cell elastomeric nitrile rubber tabular insulation between chiller unit to AHU units for supply & return refrigerant line including necessary supports/ brassings for laying in proper alignment and height complete all as specified & directed
Supply and fixing 3 way motorised valve for air handling unit having dehumidified CFM of 11200 complete all as specified and directed.
Supply and fix on wall/pole with necessary arrangments in repair Glow sign board of size 4.5ft x 2 ft x 0.5ft of iron body from 5 sides and in front Acrylic sheet of same size showing the detail of substation/installation including two no LED tubelight inside the box with all necessary connection all as directed at site. Note : Detail of substaion/installation will be given by Engr-in-charge.
Supply and fix in repair digital type of 0-10v low pressure sensor with temprature range 15 degree centrigate to 30 degree centegrate all as directed at site
Supply and fix in repair digital type of 0-10v High pressure sensor for pressure measure upto 10 mpa all as directed at site
Supply and fix in repair CT Fan motor of 5 HP Motor including taking down existing motor all as directed at site
Supply and fix in repair CT Fan motor blade of 5 HP Motor including taking down existing motor all as directed at site
S&F in replacement GI steel tubing 'medium grade' on wall/floor including cutting, threading of required size suitable for connection to condenser, mono block pump, cooling tower, gate valve including all GI fittings of 80mm dia bore complete all as specified and directed
S&F in replacement, 25 mm dia gun metal stop valve with iron wheel head screwed both ends for iron pipe complete all as specified & directed.
S&F in replacement, 20 mm dia stop valves, cast copper alloy, screwed down , high pressure, with crutch or butter fly handle, screwed both ends for iron pipes or for unions complete all as specified and directed.
S&F in replacement 80mm gun metal gate valve with iron wheel head screwed both ends for iron pipe and fixed complete all as specified & directed.
S&F in replacement cast iron non return valve of 80 mm bore with flanged end, ISI marked complete with jointing materials complete all as specified and directed.
supply & fix in replacement, moisture and liquid indicator suitable for 2x11 TR package type AC plants complete all as specified and directed.
Supply & fix in replacement, eliminator filter drier complete all as specified and directed.
Dismenteling & taking out existing defective/ burnt parts of AC electric blower motor of any description & in any position of capacity 5.0 HP for rewinding from approved workshop including transporting the same to workshop & back after rewinding the same motor with and including super enamelled copper winding wire of superior quality of existing size/ gauge & No of turns and insulation of the same with & including insulating materials such as leatherised fibre glass, illuminous paper, cotton tape, glass sleeving, insulating varnish etc as per manufacturers instructions including cutting and taking out existing burnt/ short circuited winding wires including replacement of existing bushes, bearings & starting condenser with new bushes, bearings & starting condenser complete and re-assembling and refixing of the same motor at its original position after repair, making all necessary connections, commissioning and testing on completion complete all as specified and directed.
Dismantling & taking out existing defective/ burnt parts of AC electric condensor (Outdoor unit) fan motor of any description & in any position of capacity 3.75W for rewinding from approved workshop including transporting the same to workshop & back after rewinding the same motor with and including super enamelled copper winding wire of superior quality of existing size/ gauge & No of turns and insulation of the same with & including insulating materials such as leatherised fibre glass, illuminous paper, cotton tape, glass sleeving, insulating varnish etc as per manufacturers instructions including cutting and taking out existing burnt/ short circuited winding wires including replacement of existing bushes, bearings & starting condenser with new bushes, bearings & starting condenser complete and re-assembling and refixing of the same motor at its original position after repair, making all necessary connections, commissioning and testing on completion complete all as specified and directed.
supply & fix in replacement, fan blade (three blade) of existing size & model of condensor units of capacity 11.0 TR complete all as specified and directed.
supply & fix in replacement, fan blade (four blade) of existing size & model of condensor units of capacity 8.75 TR complete all as specified and directed.
supply & fix in replacement, fan blade (four blade) of existing size & model of condensor units of capacity 5.50 TR complete all as specified and directed.
supply & fix in replacement, glass fuses of rated 6 Amps complete all as specified and directed.
supply & fix in replacement, timer having range 1-10Sec, 230 volts complete all as specified and directed.
Supply only,supply & fix in replacement, connector three phase, 4-pole, 100 Amps rated complete all as specified and directed.
supply & fix in replacement, connector single phase, 10 Amps rated complete all as specified and directed.
supply & fix in replacement, control fuse with base of capacity 2 to 20 Amps complete all as specified and directed.
supply & fix in replacement,, earth fault relay with CBCT, 230 volts AC, coil of capacity 0-100 Amps complete all as specified and directed.
supply & fix in replacement, earth fault relay with CBCT, 230 volts AC, coil of capacity 0-40 Amps complete all as specified and directed.
supply & fix in replacement, indication lamp LED type, 22.5mm dia, 230 volts complete all as specified and directed.
M&L for fixing new evaporative/cooling coil in replacement of existing in door unit including jointing all liquid and gas lines duly sholdering, breazing ,copper welding all as per manufacturer of capacity 22 TR capacity, model DPUASC22OX of Voltas Make complete all as directed at site.
supply & fix in replacement, heavy duty copper tubing suitable for package type AC unit gas piping of size 9/8" with insulating material and fixing supports/ saddles etc as required at site to match existing line complete all as specified and directed.
supply & fix in replacement, heavy duty copper tubing suitable for package type AC unit gas piping of size 7/8" with insulating material and fixing supports/ saddles etc as required at site to match existing line complete all as specified and directed.
supply & fix in replacement, pin type HP/LP pin type cut out switch suitable for and including fixing by copper welding on discharge/ suction line of 11 to 5.5 TR capacity package type AC plant unit complete all as specified and directed at site by Engr-in-Charge
supply & fix in replacement, suction/discharge line control valve of size 9/8" to 7/8" suitable for and including fixing by copper welding on discharge/ suction line of 11 to 5.5 TR capacity package type AC plant unit complete all as specified and directed at site by Engr-in-Charge
Supply and fix in repairs three Phase Auto Sequence Corrector of 200 Amps, 440volt Suitable for correcting the RYB phase sequence, whenever the sequence is changed or reversed all as directed by Engr-in-charge
Supply and fix in repair MCB TP 63 Amp,50 Hz,, 10 KA rupturing capacity, 240 volts (C-series) 10 KA.
Supply and fix in repair MCB TP, 40 Amp,50 Hz, 10 KA rupturing capacity, 240 volts (C-series) 10 KA.
supply & fix in replacement, adjustable thermal & adjustable magnetic setting type MCCB three pole with enclosure, 415 volts, 50 Hz, 200 Amps with breaking capacity 25 kA complete all as specified & directed.
supply & fix in replacement, adjustable thermal & adjustable magnetic setting type MCCB three pole with enclosure, 415 volts, 50 Hz, 100 Amps with breaking capacity 16 kA complete all as specified & directed.
supply & fix in replacement, adjustable thermal & fixed magnetic setting type MCCB three pole with enclosure, 415 volts, 50 Hz, 100 to 63 Amps with breaking capacity 16 kA complete all as specified & directed.
Excavation in trenches not exceeding 1.5m wide and not exceeding 1.5 m depth for laying of cable/ stay assy/LT poles and getting out in hard/dense soil complete all as specified and directed.
Returning filling incl spreading watering and well ramming in layers not exceeding 25cm in hard and dense soil.
Removing excavated material not exceeding 50 mtrs and depositing where directed at a level n. exc 1.5mtr above the starting point.
Sand cushioning to underground cable complete all as specified in clause 19.75 of SSR Part - I.
Material and labour for un-reinforced pre-cast concrete cable covers, class LV type-1, flat size 250mm x 150mm x 40mm thick complete all as specified.
Taking Down UNSV Cable and Supply and laying XLPE insulated armoured heavy duty electric cable with aluminium conductor (Stranded) 1100V grade cross-sectional area 50 Sqmm 3.5 core laid in trenches or passing through pipe or fixed on pole etc complete all as specified and directed by Engr-in-Charge.
M&L for earthing complete, with GI earth plate electrode of size 60 cm x 60 cm x 6 mm thick burried directly in ground (earth pit not less than 2.25 m deep below ground level) with top edge of the plate not less than 1.5 m below the normal ground level connected with GI strip 25 x 4 mm by means of bolts, nuts, check nuts and washers of galvanized iron and using charcoal and salt upto 150 mm above plate edge level including PCC pit in PCC 1:2:4 type B-1 using 20 mm graded crushed stone aggregate, PCC frame with 40 mm thick RCC cover reinforced with 8 mm dia deformed bars C/C in both way & 10 mm dia bar lifting handle, including excavation and earth work in any type of soil, 20 mm bore medium grade GI watering pipe with funnel and wire mesh and 40 mm bore light grade GI protection pipe earth lead connected to and including test point complete all as shown in electrical plate No.3 of SSR part-I of 2009 connected to equipment and testing on completion including complete all as specified and directed.
M&L for earthing complete with galvanized steel earth plate electrodes 600 mm x 600 mm x 6 mm thick buried directly in ground earth plate not less than 2.25 mtr deep below normal ground level with top edge of the plate not less than 1.5 mtr below normal ground level connected to and including galvanized steel wire 4.0 mm dia by means of bolts, nuts, check nuts and washers of galvanized iron and using charcoal and salt upto 150 mm above plate plate edge level including PCC pit in PCC 1:2:4 type B-1 using 20 mm graded crushed stone aggregate, PCC frame with 40 mm thick RCC cover reinforced with 8 mm dia deformed bars C/C in both way & 10 mm dia bar lifting handle, including excavation and earth work in any type of soil, 20 mm bore medium grade GI watering pipe with funnel and wire mesh and 15 mm bore light grade GI protection pipe earth lead connected to and including test point complete all as shown in electrical plate No.3 of SSR part-I of 2009 connected to equipment and testing on completion including complete all as specified and directed.
M&L for chemical earthing (Set of Three) complete, with copper earth plate of size 90 x 60cm x 5mmmm thick burried directly in ground (earth pit not less than 2.25 m deep below ground level) with top edge of the plate not less than 1.5 m below the normal ground level connected with copper strip 50 x 6mm by means of bolts, nuts, check nuts and washers of copper and using the chenical compound,often referred to as ground enhancement material GEM is a mixture of conductive component designed to lower soil redisitvity and improve moisture retention above plate edge level including PCC pit in PCC 1:2:4 type B-1 using 20 mm graded crushed stone aggregate, PCC frame with 40 mm thick RCC cover reinforced with 8 mm dia deformed bars C/C in both way & 10 mm dia bar lifting handle, including excavation and earth work in any type of soil, 20 mm bore medium grade GI watering pipe with funnel and wire mesh and 40 mm bore light grade GI protection pipe earth lead connected to and including test point complete all as shown in electrical plate No.3 of SSR part-I of 2009 connected to equipment and testing on completion including complete all as specified and directed Note : Earth result should not be more than 0.1 Ohm and test report will be submitted by contractor
M&L for chemical earthing complete, with copper earth plate of size 60cm × 60cm ×3.15mm thick burried directly in ground (earth pit not less than 2.25 m deep below ground level) with top edge of the plate not less than 1.5 m below the normal ground level connected with copper strip 20 x 3 mm by means of bolts, nuts, check nuts and washers of copper and using the chenical compound,often referred to as ground enhancement material GEM is a mixture of conductive component designed to lower soil redisitvity and improve moisture retention above plate edge level including PCC pit in PCC 1:2:4 type B-1 using 20 mm graded crushed stone aggregate, PCC frame with 40 mm thick RCC cover reinforced with 8 mm dia deformed bars C/C in both way & 10 mm dia bar lifting handle, including excavation and earth work in any type of soil, 20 mm bore medium grade GI watering pipe with funnel and wire mesh and 40 mm bore light grade GI protection pipe earth lead connected to and including test point complete all as shown in electrical plate No.3 of SSR part-I of 2009 connected to equipment and testing on completion including complete all as specified and directed Note : Earth result should be below 1 Ohm and test report will be submitted by contractor
S S TRADERS (BID ID -3452181)
M/S J J ENTERPRISES (BID ID -3446465)
BRITE INDUSTRIES (BID ID -3446303)
AIRCOM (BID ID -3441930)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .