| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹18.5 LAccepted-AOC | L1 | Accepted-AOC Lowest Bidder | |
| 2 | L2₹22.9 L+₹3.9 L (20.6%)Rejected-Finance | L2 | Rejected-Finance High Rate | |
| 3 | L3₹23.5 L+₹4.5 L (23.6%)Rejected-Finance | L3 | Rejected-Finance High Rate | |
| 4 | L4₹26.4 L+₹7.4 L (38.8%)Rejected-Finance | L4 | Rejected-Finance High Rate | |
| 5 | L5₹27.0 L+₹8.0 L (42.4%)Rejected-Finance 24 824 GOVERDHAN COLONY MAIN BHIND ROAD GOLE KA MANDIR | L5 | Rejected-Finance High Rate |
| Sl No | Description | Qty | Unit | ANUSHKA BUILDERS L6 | M/s Asrani and sons L3 | M.S.TRADERS L4 | Akanksha Enterprises L8 | ANAND ENTERPRISES L5 | SGS ENERGY L7 | EAST PUNE SERVICES L2 | Mepcon Projects Pvt LTd L1 |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1.00 | Taking down old unserviceable/deteriorated batten/PVC conduit point wiring aluminium/ copper from existing place i.e. light, fan, socket or power points complete with any type of unserviceable fittings such as switches, sockets,bell push , ceiling rose, pendants, Holders, etc and making good all disturbed surface to wall, floor etc by means of cement mortar or plaster of Paris and to match / finish new surface as the existing surface either by using same colour distemper, Putti or white / colour wash all as required and directed by Engineer-in-Charge. | 869 | Per Point | 21 ₹18,249 | 15 ₹13,035 | 25 ₹21,725 | 10 ₹8,690 | 20 ₹17,380 | 25 ₹21,725 | 50 ₹43,450 | 1 ₹869 Lowest |
| 2.00M & L for concealed point wiring for (Simple/Modular) in wall and floor with necessary fixing arrangements with PVC-FRLS insulated and unsheathed copper multi-stranded conductor of size 1.5 Sqmm, 1100 volts grade drawn in and including rigid non metallic PVC conduit medium grade ISI marked not less than 20 mm dia with all conduit including accessories/ fittings such as junction boxes, bends, tee, elbow etc including anodized MS sunken boxes made out of MS sheet of thickness not less than 1.2 mm with earth dolly and Bakelite laminated sheet 3 mm thick ISI marked for fixing of switches / sockets, fan regulators, wall mounting fittings, door bell & bulkhead etc with MS screw and cup washers OR (for modular fittings) recuired size Modular sunken boxes including modular frame / cover plate suitable for mounting switches /sockets etc PVC-FRLS insulated and unsheathed copper multi-stranded conductor of size 1.5 Sqmm, 1100 volts grade for continuous earthing including cutting the chases and making good the surface by cement mortar and for matching / finishing of new surfaces either by means of Putti or distemper / colour wash with same existing colour surfaces all as specified and directed by Engineer-in-Charge for the following:- | |||||||||||
| 2.01 | One light /Fan/Bell point controlled by one switch 6/5 Amp one way single pole. | 177 | Per Point | 750 ₹1,32,750 | 600 ₹1,06,200 | 650 ₹1,15,050 | 700 ₹1,23,900 | 650 ₹1,15,050 | 550 ₹97,350 | 450 ₹79,650 Lowest | 500 ₹88,500 |
| 2.02 | One 3 pin socket outlet 6/5 Amps controlled by one switch on the same board with other switches. | 29 | Per Point | 350 ₹10,150 | 200 ₹5,800 | 250 ₹7,250 | 250 ₹7,250 | 250 ₹7,250 | 500 ₹14,500 | 450 ₹13,050 | 120 ₹3,480 Lowest |
| 2.03 | One 3 pin 6/5 Amp socket outlet controlled by one switch independent board. | 29 | Per Point | 750 ₹21,750 | 650 ₹18,850 | 650 ₹18,850 | 700 ₹20,300 | 650 ₹18,850 | 400 ₹11,600 Lowest | 550 ₹15,950 | 500 ₹14,500 |
| 2.04 | One 3 pin 6/5 Amp socket outlet controlled by one switch independent board but below/ side the switch board of light point in same vertical / horzintal plane. | 14 | Per Point | 750 ₹10,500 | 300 ₹4,200 | 320 ₹4,480 | 700 ₹9,800 | 385 ₹5,390 | 250 ₹3,500 | 550 ₹7,700 | 150 ₹2,100 Lowest |
| 2.05 | All as per item No 2 here-in-before but for power point wiring with 2.5 Sqmm PVC-FRLS insulated, unsheathed, copper conductor, stranded 1100 volt grade cable and 1.5 Sqmm PVC-FRLS insulated, unsheathed, copper conductor, stranded 1100 volt grade cable as continuous earth lead. | 39 | Per Point | 890 ₹34,710 | 750 ₹29,250 | 800 ₹31,200 | 900 ₹35,100 | 550 ₹21,450 Lowest | 550 ₹21,450 Lowest | 850 ₹33,150 | 600 ₹23,400 |
| 3.00M & L for Surface point wiring (Simple and Modular) on wall/ceilng with necessary fixing arrangements with PVC-FRLS insulated and unsheathed copper multi-stranded conductor of size 1.5 Sqmm, 1100 volts grade drawn in and including rigid non metallic PVC conduit medium grade ISI marked not less than 20 mm dia / PVC Casing & Caping not less then (20 x 12 ) mm including all accessories/ fittings such as junction boxes, bends, tee, elbow etc including suitable size surface PVC box along with its cover for fixing of switches / sockets, fan regulators, wall mounting fittings, door bell & bulkhead etc with MS screw and cup washers OR required size Modular sunken boxes including modular frame / cover plate suitable for mounting switches /sockets etc including PVC-FRLS insulated and unsheathed copper multi-stranded conductor of size 1.5 Sqmm, 1100 volts grade for continuous earthing including fixing of switch/socket/regulator/blank plate complete all as specified and directed by Engineer-in-Charge for the following:- | |||||||||||
| 3.01 | One light /Fan/Bell point controlled by one switch 6/5 Amp one way single pole. | 334 | Per Point | 795 ₹2,65,530 | 550 ₹1,83,700 | 600 ₹2,00,400 | 650 ₹2,17,100 | 550 ₹1,83,700 | 450 ₹1,50,300 | 450 ₹1,50,300 | 400 ₹1,33,600 Lowest |
| 3.02 | One 3 pin socket outlet 6/5 Amps controlled by one switch on the same board with other switches. | 55 | Per Point | 350 ₹19,250 | 150 ₹8,250 | 200 ₹11,000 | 150 ₹8,250 | 200 ₹11,000 | 400 ₹22,000 | 450 ₹24,750 | 120 ₹6,600 Lowest |
Tender Value
₹29.4 L
EMD Value
₹59,000
Closing Date
27 Aug 2025, 6:00 pmClosed
Garrison Engineer (Central) Pune
Garrison Engineer (Central) Pune, Arjun Marg, Pune-411001
8624 REPAIR/ REPLACEMENT OF INTERNAL ELECTRIC WIRING, FITINGS, FIXTURES AND CONNECTED ELECTRICAL ITEMS AT MARRIED ACCN FOR OFFR, JCOS. ORS AND SERVANT QTRS AND WELCOME MAINT FOR INTERNAL E/M SERVICES FOR CERTAIN ACCN AT AFMC AREA UNDER GE (C) PUNE
2025_MES_723052_1
8624 REPAIR/ REPLACEMENT OF INTERNAL ELECTRIC WIRING, FITINGS, FIXTURES AND CONNECTED ELECTRICAL ITE
Open Tender
Civil Works
Item Rate
270 days
Garrison Engineer (Central) Pune
Please refer Tender documents.
9 documents required · 9 mandatory
₹500
Garrison Engineer (Central) Pune
₹59,000
Yes
14 Oct 2025
30 Jul 2025
29 Aug 2025
30 Jul 2025
27 Aug 2025
13 Aug 2025
Amount
Taking down old unserviceable/deteriorated batten/PVC conduit point wiring aluminium/ copper from existing place i.e. light, fan, socket or power points complete with any type of unserviceable fittings such as switches, sockets,bell push , ceiling rose, pendants, Holders, etc and making good all disturbed surface to wall, floor etc by means of cement mortar or plaster of Paris and to match / finish new surface as the existing surface either by using same colour distemper, Putti or white / colour wash all as required and directed by Engineer-in-Charge.
M & L for concealed point wiring for (Simple/Modular) in wall and floor with necessary fixing arrangements with PVC-FRLS insulated and unsheathed copper multi-stranded conductor of size 1.5 Sqmm, 1100 volts grade drawn in and including rigid non metallic PVC conduit medium grade ISI marked not less than 20 mm dia with all conduit including accessories/ fittings such as junction boxes, bends, tee, elbow etc including anodized MS sunken boxes made out of MS sheet of thickness not less than 1.2 mm with earth dolly and Bakelite laminated sheet 3 mm thick ISI marked for fixing of switches / sockets, fan regulators, wall mounting fittings, door bell & bulkhead etc with MS screw and cup washers OR (for modular fittings) recuired size Modular sunken boxes including modular frame / cover plate suitable for mounting switches /sockets etc PVC-FRLS insulated and unsheathed copper multi-stranded conductor of size 1.5 Sqmm, 1100 volts grade for continuous earthing including cutting the chases and making good the surface by cement mortar and for matching / finishing of new surfaces either by means of Putti or distemper / colour wash with same existing colour surfaces all as specified and directed by Engineer-in-Charge for the following:-
One light /Fan/Bell point controlled by one switch 6/5 Amp one way single pole.
One 3 pin socket outlet 6/5 Amps controlled by one switch on the same board with other switches.
One 3 pin 6/5 Amp socket outlet controlled by one switch independent board.
One 3 pin 6/5 Amp socket outlet controlled by one switch independent board but below/ side the switch board of light point in same vertical / horzintal plane.
All as per item No 2 here-in-before but for power point wiring with 2.5 Sqmm PVC-FRLS insulated, unsheathed, copper conductor, stranded 1100 volt grade cable and 1.5 Sqmm PVC-FRLS insulated, unsheathed, copper conductor, stranded 1100 volt grade cable as continuous earth lead.
M & L for Surface point wiring (Simple and Modular) on wall/ceilng with necessary fixing arrangements with PVC-FRLS insulated and unsheathed copper multi-stranded conductor of size 1.5 Sqmm, 1100 volts grade drawn in and including rigid non metallic PVC conduit medium grade ISI marked not less than 20 mm dia / PVC Casing & Caping not less then (20 x 12 ) mm including all accessories/ fittings such as junction boxes, bends, tee, elbow etc including suitable size surface PVC box along with its cover for fixing of switches / sockets, fan regulators, wall mounting fittings, door bell & bulkhead etc with MS screw and cup washers OR required size Modular sunken boxes including modular frame / cover plate suitable for mounting switches /sockets etc including PVC-FRLS insulated and unsheathed copper multi-stranded conductor of size 1.5 Sqmm, 1100 volts grade for continuous earthing including fixing of switch/socket/regulator/blank plate complete all as specified and directed by Engineer-in-Charge for the following:-
One light /Fan/Bell point controlled by one switch 6/5 Amp one way single pole.
One 3 pin socket outlet 6/5 Amps controlled by one switch on the same board with other switches.
One 3 pin 6/5 Amp socket outlet controlled by one switch independent board.
One 3 pin 6/5 Amp socket outlet controlled by one switch independent board but below/ side the switch board of light point in same vertical / horzintal plane.
All as per item No 3 here-in-before but for power point wiring with 2.5 Sqmm PVC-FRLS insulated, unsheathed, copper conductor, stranded 1100 volt grade cable and 1.5 Sqmm PVC-FRLS insulated, unsheathed, copper conductor, stranded 1100 volt grade cable as continuous earth lead.
Taking down old unserviceable/deteriorated point wiring aluminium/ copper (excluding PVC conduit/casing & caping & GI/PVC switch box any type and size) from existing place for light light, fan, socket or power points complete with any type of unserviceable fittings such as switches, sockets,bell push , ceiling rose, pendants, Holders sunken box, etc and making good all disturbed surface to wall, floor etc by means of cement mortar or plaster of Paris and to match / finish new surface as the existing surface either by using same colour distemper, Putti or white / colour wash all as required and directed by Engineer-in-Charge.
M&L for drawing the wire in existing conduit steel/PVC casing & caping any type and size ,complete with point wiring with PVC-FRLS insulated and unsheathed copper multi-stranded conductor of size 1.5 Sqmm, 1100 volts grade along with one single run of same size and type of copper wire as continuous earth wire to common earth dolly in old existing sunken terminal boxes pressed MS/GI/PVC boxes of any type and size for mounting switch, socket etc along with screw and cup washers with all accessories and making good to disturbed surface with cement mortar and matching surface with existing white/colour wash, oil bound or cement base paint etc to match with existing surface complete all as specified and directed and suitable for the following: -
One light /Fan/Bell point controlled by one switch 6/5 Amp one way single pole.
One 3 pin socket outlet 6/5 Amps controlled by one switch on the same board with other switches.
One 3 pin 6/5 Amp socket outlet controlled by one switch independent board.
One 3 pin 6/5 Amp socket outlet controlled by one switch independent board but below/ side the switch board of light point in same vertical / horzintal plane.
All as per item No 5 here-in-before but for power point wiring with 2.5 Sqmm PVC-FRLS insulated, unsheathed, copper conductor, stranded 1100 volt grade cable and 1.5 Sqmm PVC-FRLS insulated, unsheathed, copper conductor, stranded 1100 volt grade cable as continuous earth lead.
S & F as replacement of modular switch 6A SP one - way 230V white ivory finish complete all as specified
S & F as replacement of modular switch 16A SP one - way 230V white ivory finish complete all as specified
S & F as replacement of modular socket outlet 2/3 pin 6 amps, multipurpose 2 module 230 Volts, single pole one way suitable for plug tops, complete all as specified.
S & F as replacement of modular socket outlet 2/3 pin 16 amps, multipurpose 2 module 230 Volts, single pole one way suitable for plug tops, complete all as specified.
S & F as replacement of Modular type stepped electronic fan regulator of two module all as specified & directed
M&L as in replacement for modular bell push,single pole,one way,6 Amp suitable for 1 module complete all as specified & directed
S & F as in replacement of modular switch 6A SP Two- way 230V white ivory finish complete all as specified
M&L as in replacement for modular white cover plate with frame and Flush box for 1 to 4 Module complete all as specified & directed
M&L as replacement for modular white cover plate with frame and flush box for 6 to 12 module complete all as specified & directed
Supply & Fixing as in replacement medium step type fan regulator 80 Watt, 240 Volt AC, socket size, medium step marked complete all as specified and directed.
S&F as in replacement switch piano flush type (ISI marked), single pole, one way 6 Amp, 240 Volts complete all as specified and as directed.
S&F as in replacement switch piano flush type (ISI marked), single pole, one way 16/15 Amps, 240 Volts including complete all as specified and as directed.
S&F as in replacement socket outlet 3 pin, 6 Amp piano flush type including complete all as specified and as directed.
S&F as in replacement socket outlet, 2 in 1, 3/5 pin 6 / 16 Amp, piano flush type complete all as specified and as directed
S&F as in replacement bell push 5/6 Amps SP flush type complete all as specified and as directed.
S&F as in replacement Ding dong sound door call bell electric AC 240 volt, 50 Hz ding dong type including taking down unserviceable complete all as specified and as directed.
S&F as in replacement Angle lamp /batten holder fixed on wall /ceiling all as approved and directed by Engineer-in-charge.
S&F as in replacement ceiling rose, surface bakelite, 65mm x 50mm, two to three terminals complete all as specified and as directed.
Supply and fixing as in repairs Metal clad socket outlet with single pole and nuetral enclosure with two pin and earth plug socket complete with one single pole MCB 20 Amps complete all as specified and directed by EIC.
Disconnecting and taking down and opening the ceiling fan of size 1200/1400 mm sweep/Exhaust fan up to 300 mm sweep carefully dismantling complete for servicing by cleaning the bearing/bush by cleaining solution and replacing the split pin and unserviceable items like bearing, bushes, rubber real, condenser, flexible cable, canopy, etc., assembling Ceiling fan and refixing in the original place or as per direction duly connection and testing complete along with replacement of Ball bearing , bushes, condenser, fan clamp with u clamp, rubber reel split pin, fan hook all as per existing size and shape complete with synthetic enamel paint by spray painting complete all as specified and directed by Engineer-in-Charge.
M & L as in replacement of Sub main wiring complete with two single core 2.5 sqmm,1100 volts grade, PVC insulated, stranded copper conductor FRLS cable with continuous copper earth conductor of 2.5 sqmm in and including PVC conduit/Casing caping incl accessories complete all as specified. (Note:- (i) Making good of disturbed surfaces will be done by contractor without any claims. (ii) 3 runs of 2.5 Sqmm conductor and one run of PVC conduit/casing caping shall be measured as one unit length.)
M & L as in replacement of Sub main wiring complete with two single core 4 sqmm,1100 volts grade, PVC insulated, stranded copper conductor FRLS cable with continuous copper earth conductor of 4 sqmm in and including PVC conduit /casing caping incl accessories complete all as specified. (Note:- (i) Making good of disturbed surfaces will be done by contractor without any claims. (ii) 3 runs of 4 Sqmm conductor and one run of PVC conduit /casing caping shall be measured as one unit length.)
M & L as in replacement of Sub main wiring complete with Two single core 6 sqmm and one core of 6 sqmm earth wire,1100volts FRLS grade, PVC insulated, stranded copper conductor cable with continuous copper earth conductor in and including PVC Conduit /casing caping including accessaries complete. (Note:- Making good of disturbed surfaces will be done by contractor without any claims.(ii) 3 runs of 6 Sqmm conductor and one run of PVC conduig/casing caping shall be measured as one unit length.)
M & L as in replacement of Sub main wiring complete with two single core 1.5 sqmm,1100 volts grade, PVC insulated, stranded copper conductor FRLS cable with continuous copper earth conductor of 1.5 sqmm in and including PVC conduit/Casing caping incl accessories complete all as specified. (Note:- (i) Making good of disturbed surfaces will be done by contractor without any claims. (ii) 3 runs of 1.5 Sqmm conductor and one run of PVC conduit/casing caping shall be measured as one unit length.)
M & L as in replacement of Sub main wiring complete with four single core 6 sqmm and one core of 6 sqmm earth wire,1100volts FRLS grade, PVC insulated, stranded copper conductor cable with continuous copper earth conductor in and including PVC Conduit/casing caping including accessaries complete. (Note:- Making good of disturbed surfaces will be done by contractor without any claims.(ii) 5 runs of 6 Sqmm conductor and one run of PVC conduit shall be measured as one unit length.)
Supply and fix as in replacement of 3 Pin Plug Top 16A, White/Black 240V|3 Pin Top complete all as spd and directed.
Supply and fixing in replacement PVC conduit by Non Metallic Rigid PVC conduit, ISI Marked, medium grade of size 20 mm dia including all fittings like bends, elbow reducer, junction boxes, tee bell mouth all fixing accessories such as coupler lock, nuts, saddles pipe hooks etc complete including any requirement of Cutting & Chasing on brick wall not exceeding 10 CM girth for electrical /tele wiring and making good to disturbed surface with cement mortar 1:3 and distemper / colour wash etc to match with existing surfaces including facing / finishing complete all as specified and directed.
Supply & Fixing in replacement of LED Tube light fittings 20 W White/warm white Surface and wall mounted LED batten, 6500K colour temparature. Soft & uniform light, instant start electronic driver efficiency >85%, complete including all accessories internally pre-wired in and including connecting up with twisted flexible copper conductor cable of suitable size from ceiling rose to connector complete all as specified and directed.
S & F in replacement of LED light fittings 2'x2' of capacity 35/36 watts White/warm white LED surface/reccess environmental friendly, new genereation, aesthetically designed, ultra modern recess mounting luminaire with high brightness glare free soft illumination, white powder coated housing with LEDs, seamless front frame with flat white acrylic cover, 230 volts with all accessories internally pre wired and necessary mounting arrangements complete all as specified. .
S & F in replacement of round recessed mounted with in-built driver, power factor > .9 operating voltage 230 V, surface mounting in round shape 9/12W LED downlighter of white/neutral white/ warm white color temperature , of size as per site requirement etc along with 3 core prewired and all accessories complete all as specified and directed.
S & F in replacement of round recessed mounted with in-built driver, power factor > .9 operating voltage 230 V, surface mounting in round shape 15/18W/22 LED downlighter of white/neutral white/ warm white color temperature, of size as per site requirement etc. along with 3 core prewired and all accessories complete all as specified and directed.
Supply & Fixing in replacement of LED street/ Building light with pressure die-cast housing along with prismatic polycarbonate diffuser and LEDs with secondary optics and IP 65 protection 30 watt complete with all accessories and wall mounting bracket of suitable size including clamps, nut bolts etc. prewired 3 core flexible wire complete all as specified as directed.
S&F in replacement of LED light fitting surface and wall mounted LED batten with PVC housing & integrated electronic sensor complete in all respect of 10W cap complete all as specified and as directed
S&F in replacement of LED bulk head light fitting surface and wall mounted LED batten with complete in all respect and as per sample approved by EIC of 10W cap complete all as specified and as directed
Material and labour for disconnecting from the electric mains and Taking down opening and inspection of storage type water heater of size 25ltrs/50 Ltrs capacity and descaling with dilute hydrochloric acid, checking for water tightness of the inner tank, cable continuity, thermostat of setting at 70 degree C checking fusible plug, base assembly, stop cock including replacement of indicator lamp, rubber PVC gasket washers reassembling, refixing and reconnection the electric connections at old place and replacing unserviceable bolts and nuts, cementing work including hydraulic pressure testing with hard operated hydraulic pump complete after repair including spray painting of one coat with paint of approved make after preparation of surface. Note : (a) Labour charges for replacing the unsv spares, disconnection and reconnection of water and electric connections and items like heating element, Indicator lamps, thermostat, fusible plug, safety valve and fastnut any type and size shall be deemed to be included in unit rate quoted for this items .
M & L for Servicing / testing of Metering indoor building Panels, 03/01 Phase, 415/230 Volts all as directed as per followings :- (i) Repair / replacement of damaged hinges and locks / latches of each compartment. (ii) Cleaning of existing bus bars with CTC applying with red solution, providing bus bar insulation and refixing with new nuts, bolts, washers etc. (iii) Replacement of damaged copper cable and fixing new copper cable for incoming and outgoing connections of each MCCB / MCBs switches alongwith lugs terminals to bus bars including connector. (iv) Replacement of damaged cable protection pipe and damaged / wornout cable insulation and lugs of any size for incoming & outgoing cables. (v) Replacement of neoprene gasket and transparent acrylic sheet 3 mm for all doors of panel board. (vi) Removing, cleaning and refixing/refixing of elctric meter including connection of concerned qtrs complete. Note : Replacement of unserviceable MCCB/MCBs shall be measured & Paid separately.
S&F as in replacement of vertical 4 way TPN double door, recess mounted/wall mounted, MCCB 100 Amp 3 pole, 16 KA as incomer and outgoing through MCB SP/TP . MCCB is pre-fitted at factory & including price of MCCB, all as specified, including taking down complete . (Note : Empty space shall be covered by blanking plate and connect with lugs without any extra cost )
S&F as in replacement of MCB TPN DB 4 way double door with 200 amps rated busbar 415 V, all as specified.
Supply & Fixing in replacement of DB by SPN Distribution Box, double door of protection grade IP 43 in fine powder coated, matt finish with best CRCA sheet, fitted with shrouded neutral, insulated pin type copper bus bar, Din rail, earth bar of 8 way complete all as specified and directed.
Supply & Fixing in replacement of DB by SPN Distribution Box, double door of protection grade IP 43 in fine powder coated, matt finish with best CRCA sheet, fitted with shrouded neutral, insulated pin type copper bus bar, Din rail, earth bar of 12 way complete all as specified and directed.
Supply & Fixing in replacement of DB by SPN Distribution Box, double door of protection grade IP 43 in fine powder coated, matt finish with best CRCA sheet, fitted with shrouded neutral, insulated pin type copper bus bar, Din rail, earth bar of 4 way complete all as specified and directed.
Supply & Fixing in replacement of DB by SPN Distribution Box, double door of protection grade IP 43 in fine powder coated, matt finish with best CRCA sheet, fitted with shrouded neutral, insulated pin type copper bus bar, Din rail, earth bar of 2 way complete all as specified and directed.
supply and fixing as in replacement of MCCB 100 Amps TP/FP16 KA with fixed thermal magnetic release all as specified and directed.
Supply & Fixing as in replacement MCB SPN, 5 to 40 Amps 240 volts, AC , 10 KA breaking capacity 'C' Series,complete all as specified and directed.
Supply & Fixing as in replacement MCB SP, 06 to 40 Amps 240 volts, AC , 10 KA breaking capacity 'C' Series,"ISI marked complete all as specified and directed.
Supply & fixing as in replacement of MCB TPN, 63 Amps 440 volts, AC , 10 KA breaking capacity 'C' Series,"ISI marked and complete all as specified and directed.
Supply & fixing as in replacement of MCB Tripple pole of rated capacity 40/63 amps, 415 volts breaking capacity 10 KA, C-curve complete all as specified.
Supply and fix in replacement 1100 Volts grade PVC round sheathed (flexible) industrial cable copper multi strand condutor, 2 core , 4 Sqmm nominal cross section alongwith conduit complete all as specified and as directed.
M & L as in replacement of for earthing with galvanised steel earth plate electrode 60cmx60cmx 6.3 mm buried directly in ground earth pit not less than 2.25 m deep below normal ground level, with top edge of the plate vertically to depth of not less than 1.5 m below ground level connected to and incl GI wire 4 mm dia and GI pipe 15 mm dia light grade for protection to the extent of 7.5 m as earthing lead by means of GI bolts and nuts etc connecting to equipment with provn of charcoal and salt etc all as per electrical plate No 3 of SSR Pt-I incl RCC cover and MS angle iron frame, watering arrangement with GI pipe 20 mm dia and MS funnel, concrete pit incl excavation and earth work in any type of soil and testing on completion etc complete (NOTE:-GI earth wire and protection pipe beyond 7.5m will be measured and paid separately)
M & L in replacement 4mm dia galvanised iron or steel wire as earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn through in conduit pipe or fixed to poles or any other indicated situation for loop earthing etc as required complete all as specified and as directed.
S & F in repairs capacitor 2.5 / 3.15 MFD 230 Volt, AC supply complete
Supply and fix in replacement 1100 Volts grade PVC round sheathed (flexible) copper cable 3 core , 1.5 Sqmm nominal cross section complete all as specified and as directed.
Supply and fix in replacement 1100 Volts grade PVC round sheathed (flexible) copper cable 3 core , 2.5 Sqmm nominal cross section complete all as specified and as directed.
S&F in replacement of old sketch fitting/any type by decorative wall mounted LED lamp (white/ warm) complete all as existing type and as per sample approved and specified and directed by EIC.
Man and material for deputation of skilled electrician along with necessary tools, eqpt, and accessories for the identification and rectification of faults in wiring/DBs/light fittings any type and size, ceiling fan and ex fan, hot water storage units, The electrician shall visit various locations as directed to diagnose faults through visual inspection, continuity testing, or voltage checks etc. The job involves identifying UNSV components and carrying out minor repairs or replacements, including removing and reinstalling faulty fixtures. Minor consumable s such as insulation tape, wire tags, cables ties, screws and fasteners are deemed to be included in the above job. Note :- Any major items required for rectification of the job will be measured and paid saperately.
S & F in repairs Switch socket combination multipurpose , 3 pin, 5 Amps and 15 Amps , flush type universal complete.
S & F in repairs Switch socket combination multipurpose with Box and shutter type, 5 Amps , flush type universal complete.
Note for all above (Ser No 01 to 62) :- (a) Contractor will daily detail minimum one qualified electrician assisted by a helper at complaint cell. They will carry a ladder and necessary electrical tools to check and troubleshoot electrical complaints for various location of AFMC. The team will find out /locate the fault and carry out the maint work. (b) Complaint related to no lights, replacing of switches, sockets, , replacing burnt MCB, short circuit, voltage fluctuation due to internal wiring, repair to faulty earthing etc will be attended withing 8 hour of raising complaint. (c) The complaint can be registered Telephonic/complaint slip, WhatsApp and any other mode of communication. (d) Sufficient store shall be procured by the contractor for day to day issue to complaint.
EAST PUNE SERVICES (BID ID -3407211)
M/s Asrani and sons (BID ID -3400488)
M.S.TRADERS (BID ID -3400563)
ANAND ENTERPRISES (BID ID -3400511)
ANUSHKA BUILDERS (BID ID -3399519)
SGS ENERGY (BID ID -3396575)
Akanksha Enterprises (BID ID -3400576)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .