Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.4 CrAccepted-AOC 519 P SECTOR 3 URBAN ESTATE KURUKSHETRA 136118 | KURUKSHETRA | KURUKSHETRA | HARYANA | 136118 | ₹1.4 Cr | L1 | Accepted-AOC L1 |
| 2 | Rejected-Technical | - | - | Rejected-Technical Highe rates |
| 3 | Rejected-Technical | - | - | Rejected-Technical Higher rates |
Tender Value
Refer Docs
EMD Value
₹2.8 L
Closing Date
30 Dec 2020, 10:00 amClosed
secreary and me
cheeka
Construction of Sadbhav mandop/CSS
2020_HRY_154049_1
MCC/2020/1
Open Tender
Civil Works
Works
365 days
Construction of Sadbhav mandop/CSS
Please refer Tender documents.
2 documents required · 2 mandatory
₹20,000
Yes
₹2.8 L
Yes
31 Oct 2022
23 Dec 2020
31 Dec 2020
23 Dec 2020
30 Dec 2020
23 Dec 2020
Amount
Provding And Supply of Led HAVELLS Tube Light
Provding And Supply of HAVELLS Wall Light
Provding And Supply Orient Electric Ujala 1200 Mm Energy Saving 3 Blade Ceiling Fan
S/E of 100 WATT LED light lumaniries of philips , Bajaj / crompton / Surya with lamps to complete the job in all respects in connection of the same on the lantern carriage as per specification
SITC of Manual call point with mounting box complete as required.
Sitc of Electronic hooter 6 watt output TAC approved with a range of 25-30 mtr.
providing, installing, connecting, testing and networkable logic driven analogue addressable Main Fire Alarm Control and indicating panel.The panel shall be coupled to the PA system complete in all respect. 4 loop Panel
Wiring with 2X1.5 sqmm solid PVC insulated copper conductor 100 volt grade wires in with concealed conduit including terminations, all labour and material etc complete
Supply/Fixing of self illuminated "EXIT" sings made out from not less than 4 mm of transparent acrylic sheet of 300 x 150 mm size with self illuminated plastic words of 100 mm height suspended from ceiling by means of M.S. chain or fixed of the walls as required and as directed at site.
Supply, installation, testing and commissioning of Analogue addressable Photo Smoke Detectors based with LED shall be visible from 360deg, complete as required. (Make :/ GST/Morley)
Supply, Installation, Testing and Commissioning of Fault Isolator (GST/Morley)
Supply, Installation, Testing and Commissioning of Monitor Module. (GST/Morley)
Supply, Installation, Testing and Commissioning of Control Module. (GST/Morley)
Supply and fixing Response Indicator with Dual LED
Supply & fixing of fire extinguisher, ABC Type 6.00 kg. capacity(ISI Marked IS:15683 & TAC approved) comlete with initial charge and wall bracket, along with supply of all materials and labour for proper completion of work.PWD-2018-1131 (A)
Supply & fixing of CO2 type fire extinguisher, 6.5 kg. capacity(ISI Marked IS:2878 & TAC approved) comlete with initial charge and wall bracket, along with supply of all materials and labour for proper completion of work.PWD-2018-1132 (A)
Supply, Installation, Testing and Commissioning of M.S. Pipe 'B' Class as per IS:1239 including cutting, jointing and welding etc., and providing suitable flanges alongwith necessary fittings like Bends. Tees, Reducers etc. and coating of Primer and P.O. Red Paint. Make : QST/Jindal Gzb. 50mm
Supply, Installation, Testing and Commissioning of M.S. Pipe 'B' Class as per IS:1239 including cutting, jointing and welding etc., and providing suitable flanges alongwith necessary fittings like Bends. Tees, Reducers etc. and coating of Primer and P.O. Red Paint. Make : QST/Jindal Gzb 32 mm
Supply, Installation, Testing and Commissioning of M.S. Pipe 'B' Class as per IS:1239 including cutting, jointing and welding etc., and providing suitable flanges alongwith necessary fittings like Bends. Tees, Reducers etc. and coating of Primer and P.O. Red Paint. Make : QST/Jindal Gzb 25mm
Supply, Installation, Testing & Commissioning of Butterfly Valve Complelte in all respects.(Make : SIR/Kartar) 150 mm dia
Supply, Installation, Testing & Commissioning of Flow Switch, complete in all respects. (Make:- System Sensor) 150 mm dia
Supply, Installation, Testing & Commissioning of Alarm Control Valve, complete in all respects. (Make:- System Sensor) 150 mm dia
SITC of Sprinkler 68° deg, complete in all respects. (Make:- OMEX/ Life Guard/Safex) Pendent/Upright Type
SITC of Sprinkler 68° deg, complete in all respects. (Make:- OMEX/ Life Guard/Safex) Wall Mounted Type
Supply, Installation, testing and Commissioning of Normal type Rosette Plate for sprinkler
Supply and Laying of Armoured Cable 2x1.5 Sqmm. (Make:- Relison/ Paradise/ Polycab/Pirelli)
Supply and installation of Air vessel of 300 mm dia, 1000 mm height, 6 mm thick dished end 8 mm thick.
Supply and installation of Announcing Panel
SITC of Air release valve.
Excavating trenches in all kind of soil of required width for pipes, cables etc. including excavation for sockets and dressing of sides, ramming of bottoms, depth upto 1.5m. including getting out the excavated soil & then returning the soil as required in layers not exceeding 20cm in depth including consolidating each deposited layer by ramming, watering etc. & disposing of surplus excavated soil as directed within a lead of 50m. a) Pipes 80mm to 300mm diameter. DSR-16(2.10.1.2)
Constructing masonry Chamber 60x60x75cm, inside with 75 class designation brick work in cement mortar 1:5 (1 cement : 5 fine sand) for fire hydrants, with C.I. surface box 350x350mm top and 165mm deep (inside) with chained lid and RCC top slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) necessary excavation foundation concrete 1:5:10 (1 cement :5 fine sand : 10 graded stone aggregate 40mm nominal size) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand ) 12mm thick finished with a floating coat of neat cement complete as per standard design. DSR-16(18.36.1)
Supply, Installation, Testing and Commissioning of one coat of 4 mm thick 'PYPKOTE' or coatek tape anti rust pipe protection , primer and lap of 25 mm on external M.S. pipes to make an impermeable layer in trenches or on structural/masonry members complete including surface preparation. 150 mm dia
Supply, Installation, Testing and Commissioning of M.S. Pipe 'C Class Heavy as per IS:1239 including cutting, jointing and welding etc., and providing suitable flanges alongwith necessary fittings like Bends. Tees, Reducers etc, complete in all respect. MAKE : Jindal(Hissar)/ Bharat/Indian Tube/ Prakash)-(Under ground) a) 150mm
Supply, Installation, Testing and Commissioning of M.S. Pipe 'C Class Heavy as per IS:1239 including cutting, jointing and welding etc., and providing suitable flanges alongwith necessary fittings like Bends. Tees, Reducers etc, complete in all respect. MAKE : Jindal(Hissar)/ Bharat/Indian Tube/ Prakash)-(Under ground) b)100mm
Supply, Installation, Testing and Commissioning of M.S. Pipe 'C Class Heavy as per IS:1239 including cutting, jointing and welding etc., and providing suitable flanges alongwith necessary fittings like Bends. Tees, Reducers etc, complete in all respect. MAKE : Jindal(Hissar)/ Bharat/Indian Tube/ Prakash)-(Under ground) c) 80mm
Supply, Installation, Testing & Commissioning of NRV complete with flanges, gasket and nut bolts. MAKE : Jindal(Hissar)/ Bharat/Indian Tube/ Prakash)-(Under ground) 150 mm dia
SITC of Singal Headed Hydrant Landing Valve comprising of 80 mm dia flanged Bend 63 mm dia, with cap and chain conforming to IS:5290(Make : Newage/Minimax/Safex/Firex)
SITC of RRL Hose Pipe 63 mm dia × 15 Mtr. Long with GM Coupling conforming to IS : 636(Make - Newage/Jayshree/CRC)
SITC of Short Branch Pipe as per IS:903(Make : Newage/Safex/Firex)
Supply, Installation, Testing & Commissioning of Butterfly Valve complete with flanges, gasket, nut bolts a) 80mm
SITC of Hose Cabinet Box of 18 SWG M.S.Sheet with glass to accommodate Hose Reel Drum with Ruber Pipe with Nozzle. 2 Nos. RRL Hose and 1 No. Branch Pipe with Nozzle
Supply, Installation, Testing & Commissioning of Fire brigade inlet with 63 MM dia instantaneous inlet complete with all necessary fittings and MS enclosure with glass door made of 18/16 SWG sheet.(4 WAY)
Providing and fixing Room plates on glass/wooden partitions / glass doors as per the approved location. Size of the SS plate(Grade 304 , 1.5-2mm thk.)- 6" x 6" with acrylic black rimming sliding room occupany indicator , lettering to be embossed/etched complete as per the attached image.Font and final design subject to final approval of the architect in charge.
Providing and fixing Directional signage on toughened glass sheet .Content to be displayed using plotter cut lettering on one side of the sheet, with additional taping to achieve a unifrom background . Lettering font,size ,color and content subject to final approval of the architect in charge. Cost to include mounting of glass sheets using SS Studs on masonary wall surface or suspending the sheets using ss rods from the ceiling.
Providing and installing Fire exit sign ceiling hanged, led Emergency with Ni-cd Battery backup capable of emergency backup of 2hr. Complete with hanging accessoires to the satisfaction of Engineer-in-charge.
Providing and installing Color Coded Dustbin DUO made of FRP Size: 406B x H813 xL813mm With Plastic bucket of 60L Each Colors & Graphics to be customized as per the directions of the architect
SUPPLYING , INSTALLATION , TESTING & COMMISIONING OF 13 PASSENGER LIFTS OF FOLLOWING SPECIFICATION HAVING 5 STOP S AND APPROXIMATE TRAVEL DISTANCE OF 24 M HAVING FOLLOWING SPECIFICATIONS Product DescriptionElevator SpecificationsNumber of Persons 15Rated Load 1020 kgNumber of stops 5Number of Access sides 1Floor designations B,S , 1 ,2,3Drive System Alternating Current Voltage Frequency (ACVF)Type of controller Full Collective control - SimplexSpeed of travel 1.5m/sCar Size 1575 mm (W) x 1500 mm (D) x 2239 mm (H)Door Width 900 mmDoor Height 2100 mmRated output motor 7.7 kwCar DesignCar walls finish in Stainless Steel HairlineLED spot in ceilingCar doors finish in Stainless Steel HairlineCar door in Stainless steel finishGranite Flooring finish in Black SeaDeco Ceiling finish in Stainless Steel Mirror 304Full height mirror on rear car panel Car Operating PanelStylish, touch sensitive glass panelDoor open/close and alarm buttons
Supplying and fixing ms hooks for GI pipe.
Providing and mixing integral crystalline admixture for water proofing treatment to RCC structures like basement raft, retaining walls,reservior, sewage & water treatment plant, tunnels / subway and bridge deck etc. at the time of transporting of concrete into the drum of the ready-mix truck, using integral crystalline admixture @ 0.80% (minimum) to the weight of cement content per cubic meter of concrete) or higher as recommended by the manufacturer’s specification in reinforced cement concrete at site of work. The material shall meet the requirements as specified in ACI-212-3R- 2010 i.e. by reducing permeability of concrete by more than 90%, compared with control concrete as per DIN 1048 and resistant to 16 bar hydrostatic pressure. The crystalline admixture shall be capable of self-healing of cracks up to a width of 0.50mm. The work shall be carried out all complete as per specification and the direction of the Engineer-in-charge. The product performance shall carry guarantee for 10 years against any leakage.
Designing, fabricating, testing, protection, installing and fixing in position semi (grid) unitized system of structural glazing (with open joints) for linear as well as curvilinear portions of the building for all heights and all levels, including: A. Structural analysis & design and preparation of shop drawings for the specified design loads conforming to IS 875 part III (the system must passed the proof test at 1.5 times design wind pressure without any failure), including functional design of the aluminum sections for fixing glazing panels of various thicknesses, aluminium cleats, sleeves and splice plates etc. gaskets, screws, toggles, nuts, bolts, clamps etc., structural and weather silicone sealants, flashings, fire stop (barrier)-cum-smoke seals, microwave cured EPDM gaskets for water tightness, pressure equalisation & drainage and protection against fire hazard including: B) Fabricating and supplying serrated M.S. hot dip galvanised / Aluminium alloy of 6005 T5 brackets of required sizes, sections and profiles etc. to accommodate 3 Dimentional movement for achieving perfect verticality and fixing structural glazing system rigidly to the RCC/ masonry/structural steel framework of building structure using stainless steel anchor fasteners/ bolts, nylon seperator to prevent bimetallic contacts with nuts and washers etc. of stainless steel grade 316, of the required capacity and in required numbers. C) Providing and filling, two part pump filled, structural silicone sealant and one part weather silicone sealant compatible with the structural silicone sealant of required bite size in a clean and controlled factory / work shop environment, including double sided spacer tape, setting blocks and backer rod, all of approved grade, brand and manufacture, as per the approved sealant design, within and all around the perimeter for holding glass Making provision for drainage of moisture/ water that enters the curtain glazing system to make it watertight, by incorporating rinciples of pressure equalization, providing suitable gutter profiles at bottom (if required), making necessary holes of required sizes and of required numbers etc. complete. This item includes cost of all inputs of designing, labour for fabricating and installation of aluminium grid, installation of glazed units, T&P, scaffolding and other incidental charges including wastages etc., enabling temporary structures and services, cranes or cradles etc. as described above and as specified. The item includes the cost of getting all the structural and functional design including shop drawings checked by a structural designer, dully approved by Engineer-in-charge. The item also includes the cost of all mock ups at site, cost of all samples of the individual components for testing in an approved laboratory, field tests on the assembled working structural glazing as specified, cleaning and protection till the handing over of the building for occupation. In the end, the Contractor shall provide a water tight structural glazing having all the performance characteristics etc. all complete as required, as per the Architectural drawings, as per item description, as specified, as per the approved shop drawings and as directed by the Engineer- in-Charge. D) Providing and fixing in position flashings of solid aluminium sheet 1 mm thick and of sizes, shapes and profiles, as required as per the site conditions, to seal the gap between the building structure and all its interfaces with curtain glazing to make it watertight. Note:- 1. The cost of providing extruded aluminium frames, shadow boxes, extruded aluminium section capping for fixing in the grooves of the curtain glazing and vermin proof stainless steel wire mesh shall be paid for separately under relevant items under this subhead. However, for the purpose of payment, only the actual area of structural glazing (including width of grooves) on the external face shall be measured in sqm. up to two decimal places. Note:-2. The following performance test are to be conducted on structural glazing system if area of structural glazing exceeds 2500 Sqm from the certified laboratories accreditated by NABL(National Accreditation Board for Testing and Calibration Laboratories), Department of Science & Technologies, India. Cost of testing is payable separately. The NIT approving authority will decide the necessity of testing on the basis of cost of the work, cost of the test and importance of the work. Performance Testing of Structural glazing system Tests to be conducted in the NABL accredited lab or by any other accreditation body which operates in accordance with ISO / IEC 17011 and accredits labs as per ISO/ IEC 17025. 1) Performance Laboratory Test for Air Leakage Test (-50pa to - 300pa) & (+50pa to +300pa) as per ASTM E-283-04 testing method for a range of testing limit 1 to 200 mVhr 2) Static Water Penetration Test. (50pa to 1500p) as per ASTME- 331-09 testing method for a range up to 2000 ml. 3) Dynamic Water Penetration (50pa to 1500pa) as per AAMA 501.01- 05 testing method for a range upto 2000 ml 4) Structural Performance Deflection and deformation by static air pressure test (1.5 times design wind pressure without any failure) as per ASTME-330-10 testing method for a range upto 50 mm 5) Seismic Movement Test (upto 30 mm) as per AAMA 501.4- 09 testing method for Qualitative test, Tests to be conducted on site. 6) Onsite Test for Water Leakage for a pressure range 50 kpa to 240 kpa (35psi) upto 2000 ml
Providing, assembling and supplying vision glass panels (IGUs) comprising of hermetically-sealed 6-12- 6 mm insulated glass (double glazed) vision panel units of size and shape as required and specified, comprising of an outer heat strengthened float glass 6mm thick, of approved colour and shade with reflective soft coating on surface # 2 of approved colour and shade, an inner Heat strengthned clear float glass 6mm thick, spacer tube 12mm wide, dessicants, including primary seal and secondary seal (structural silicone sealant) etc. all complete for the required performances, as per the Architectural drawings, as per the approved shop drawings, as specified and as directed by the Engineer-in-Charge. The IGUs shall be assembled in the factory/ workshop of the glass processor. (Payment for fixing of IGU Panels in the curtain glazing is included in cost of item No.25.2) For payment, only the actual area of glass on face # 1 of the glass panels (excluding the areas of the grooves and weather silicone sealant) provided and fixed in position, shall be measured in sqm. Coloured tinted float glass 6mm thick substrate with reflective soft coating on face # 2, + 12mm Airgap + 6mm Heat Strengthened clear Glass of approved make having properties as visible Light transmittance (VLT) of 25 to 35 %, Light reflection internal 10 to 15%, light reflection external 10 to 20 %, shading coefficient (0.25- 0.28) and U value of 3.0 to 3.3 W/m2 degree K etc. The properties of performance glass shall be decided by technical sanctioning authority as per the site requirement.
Extra for openable side / top hung vision glass panels (IGUs) including providing and supplying at site all accessories and hardwares for the openable panels as specified and of the approved make such as heavy duty stainless steel friction hinges, min 4 -point cremone locking sets with stainless steel plates, handles, buffers etc. including necessary stainless steel screws/ fasteners, nuts, bolts, washers etc. all complete as per the Architectural drawings, as per the approved shop drawings, as specified and as directed by the Engineerin- Charge.
Providing, fabricating and supplying shadow box of required size and shape, for fixing in the spandrel portion of the structural glazing, in linear as well as curvilinear portions of the building by providing semi -rigid, inorganic, non-combustible fibre glass wool insulation 50 mm thick, conforming to IS: 8183 and BS: 3958 Part 5. The insulation layer shall have facing (factory bonded on surface # 1 of the fibre glass insulation layer), of black non-woven fibre glass tissue of nominal thickness 0.5 mm and nominal mass not less than 60 gm /sqm, made of randomly RESTILEed glass fibres distributed in a binder by a wet-lay process including fixing 1.5 mm thick solid aluminum sheet backing using, 6 mm thick cement board including SS rivets, nuts, bolts, washers etc complete.
Providing and supplying Spandrel Glass Panels comprising of 6 mm thick heat strengthened monolithic float glass of approved colour and shade with reflective soft coating on surface # 2 of approved colour and shade so as to match the colour and shade of the IGUs in the vision panels etc. ,all complete for the required performances as specified, as per the Architectural drawings, as per the approved shop drawings, as specified, and as directed by the Engineer- in-Charge.
Designing, fabricating, testing, installing and fixing in position Curtain Wall with Aluminium Composite Panel Cladding, with open grooves for linear as well as curvilinear portions of the building , for all heights and all levels etc. including:
(a) Structural analysis & design and preparation of shop drawings for pressure equalisation or rain screen principle as required, proper drainage of water to make it watertight including checking of all the structural and functional design. (b) Providing, fabricating and supplying and fixing panels of aluminium composite panel cladding in pan shape in metalic colour of approved shades made out of 4mm thick aluminium composite panel material consisting of 3mm thick FR grade mineral core sandwiched between two Aluminium sheets (each 0.5mm thick). The aluminium composite panel cladding sheet shall be coil coated, with Kynar 500 based PVDF / Lumiflon based fluoropolymer resin coating of approved colour and shade on face # 1 and polymer (Service) coating on face # 2 as specified using stainless steel screws, nuts, bolts, washers, cleats, weather silicone sealant, backer rods etc (c) The fastening brackets of Aluminium alloy 6005 T5 / MS with Hot Dip Galvanised with serrations and serrated washers to arrest the wind load movement, fasteners, SS 316 Pins and anchor bolts of approved make in SS 316, Nylon separators to prevent bi-metallic contacts all complete required to perform as per specification and drawing The item includes cost of all material & labour component, the cost of all mock ups at site, cost of all samples of the individual components for testing in an approved laboratory, field tests on the assembled working curtain wall with aluminium composite panel cladding, cleaning and protection of the curtain wall with aluminium composite panel cladding till the handing over of the building for occupation. Base frame work for ACP cladding is payable under the relevant aluminium item.s The Contractor shall provide curtain wall with aluminium composite panel cladding, having all the performance characteristics all complete , as per the Architectural drawings, as per item description, as specified, as per the approved shop drawings and as directed by the Engineer-in-Charge. However, for the purpose of payment, only the actual area on the external face of the curtain wall with Aluminum Composite Panel Cladding (including width of groove) shall be measured in sqm. up to two decimal places.
Design supply & installation of suspended Spider Glazing system designed to withstand the wind pressure as per IS 875 (Part-III). The Suspended System held with Spider Fittings of SS-316 Grade Steel of approved manufacturer with glass panel having 12 mm thick clear toughened glass held together with SS- 316 Grade Stainless steel Spider & bolt assembly with laminated glass fins 21 mm thick. The Glass fins and glass panel assembly shall be connected to Slab/ beams by means of SS- 316 Grade stainless steel brackets & nchor bolts and at the bottom using SS channel of 50x25x2mm using fastener & anchor bolts, non staining weather sealants of approved make, Teflon/ nylon bushes and separators to prevent bi-metallic contacts, all complete to perform as per specification and approved drawings. The complete system to be designed to accommodate thermal expansion & seismic movements etc. The joints between glass panels (6 to 8 mm) and gaps at the perimeter & in U channe of the assembly to be filled with non staining weather sealant, so as to make the entire system fully water proof & dust proof. The rate shall include all design, Engineering and shop drawing including approval from structural designer, labour, T&P, scaffolding, other incidental charges including wastage, enabling temporary services all fitting fixers nut bolts, washer, Buffer plates, fastener, anchors, SS channel laminated glass etc. all complete. For the purpose of payment, actual elevation area of Glazing including thickness of joints and the portion of Glass panel inside the SS channel shall be measured.
Supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete.
Bidder Name
Amount
Satish Kumar Gupta Contractor(GSTN-NA)
MS B.S.Construction Company(GSTN-NA)
MAHAVIRA AND SONS(GSTN-NA)
Satish Kumar Gupta Contractor
MAHAVIRA AND SONS
MS B.S.Construction Company
Satish Kumar Gupta Contractor
stage.html
html • 0.04 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_206335.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .