Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹41.8 LAccepted-AOC 385 GROUND FLOOR GANESH MURTI NAGAR CAPTAIN PRAKASH PETHE MARG BACKBAY BUS DEPOT CUFFE PARADE COLABA MUMBAI 400 005 | MUMBAI | MAHARASHTRA | 400005 | L1 | Accepted-AOC Being lowest tenderer | |
| 2 | L2₹42.4 L+₹34,278 (0.81%)Rejected-Finance | L2 | Rejected-Finance Being other than lowest tenderer |
Tender Value
Refer Docs
EMD Value
₹99,000
Closing Date
9 Mar 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (NW) KUNJALI
Garrison Engineer NW Kunjali Dr Homi Bhabha Road Navy Nagar Colaba Mumbai 400005
8348 ADDITION ALTERNATION TO PROVIDER STORAGE FACILITY OF WED MBI UNDER BUILDING A45 ND MBI ADDL ALTN AND IMPROVEMENT TO LEFT WING 2ND FLOOR AT MANOR HOUSE AT INS ANGRE MUMBAI ADDITIONAL ALTERATION OF DRAIN LINE NEAR SHIPS WASHING AREA AT INS AGNIBAH
2021_MES_420636_1
8348/E8
Open Tender
Civil Works
Item Rate
183 days
GE (NW) KUNJALI
Please refer tender documents
7 documents required · 7 mandatory
₹500
Yes
GE (NW) KUNJALI
₹99,000
Yes
23 Mar 2021
9 Feb 2021
11 Mar 2021
17 Feb 2021
9 Mar 2021
23 Feb 2021
9 Feb 2021 - 17 Feb 2021
60 days
Amount
Taking down chowkats or frames but n exc 1.5 sqm each but with shutters (without taking off shutters from the frame) complete all as specified and as directed.
Taking down chowkats or frames exc 1.5 sqm but n exc 4 sqm each but with shutters (without taking off shutters from the frame) complete all as specified and as directed.
Taking down 15mm bore, GI tubing and connections including cleaning for refixing or removal to store complete all as specified and as directed.
All as per Srl item No 03 here in before but 20 mm bore GI tubing.
Demolition of plain cement concrete of any description and in any position not other wise specifically provided for complete all as specified and directed.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and disposing the rubbish material to the out side of MD land.
Taking down cement plaster on brick on stone walls etc including raking out joint, hacking for key, scrubbing down with water etc complete all as specified and directed.
Taking down CI Pipe 75/100mm bore dia of any description and size fixed to wall etc complete.
Demolition of cement concrete (unreinforced) in ground floor and in paving not exceeding 15 cm thickness (below or above ground level) complete all as specified.
Demolition of stone/brick masonry, built in cement mortar including all quoins, arches, pillars etc. but excluding ashlar facings dressed stone work and pre cast concrete articles complete all as specified and directed.
M & L for Pre cast Cement Concrete block masonry type C-1 1:3:6 (20 mm graded aggregate) with solid blocks exc 10 cm in width and setting in cement mortar in 1:6, all as specified and directed.
M&L brickwork with sub class 'B' bricks , straight or curved on plan exc 6m mean raidus built in cement mortar 1:6 complete all as specified and directed
Dismantling of wall panneling, partation and ceiling boards (fibre, pulp, insulation) or insulation boards, bonded wool, blanket slab incl aluminium grid frame work complete all as specified and as directed
S&F in repair for Amstrong ceiling made out of 600x600x15 mm thick classic lite (RH-95) mineral fibre acoustics ceiling board/tiles with and including powder coated exposed GI grid suspension system (E-Grid T-2430 or equvalent load carrying capacity with mid span deflection not exc. 1/360 span with hanger spacing of 1200mm c/c) consisting of main runner 3600mm long, cross Tee 1200mm/600mm long and wall angle. The main runners to be placed @ 1200mm, the cross Tee 1200mm will be inserted in the pre cut slots of main runner at a regular interval of 600mm to form a modular grid of 1200mmX600mm. Additional cross Tees of 600mm shall be placed perpendicular to the cross tee 1200mm long to finally form a grid of 600mmX600mm. Grid of modular size 600mmX600mm shall be supported by 6 mm dia G.I. wire for suspending , bolts, necessary washer, nut/ clits/ pin hook etc for securing frame work to ceiling to the snap gridcomplete all as per manufacturer's instruction. (Make : Amstrong or equivalent as approved by GE)
S&F in repair 19 mm thick pre-laminated Medium Density board,both side decorative lamination interior grade,fixed in aluminium/ wooden frame work complete all as specified and directed.
S&F aluminium window, doors with shutters / frames / partitions made out of extruded powder coasted aluminium sections, with sliding or openable shutters including frame & necessary joining cleats, glazing clip, powder coated aluminium snap beading, screws etc; complete and also including powder coated aluminium fittings such as cobra hinges, butt hinges, tower bolts hooks and eyes, peg syays and handles including connected items, with and including, making good to the disturbed portion with its original specification, complete all as specified and directed. Note :- (i) The rate quoted shall be inclusive of the cost of neoprene beading, glazing pin. screws and powder coated fittings such as hinges, handles, locking arrangement etc as required, which shall not be measured for arriving the weight. (ii) Item shall be paid as per weight of aluminium section. (iii) The rate shall also be inclusive of complete packing with silicon gel around contacting surfaces of aluminium work, and including matching the existing surface area.
S&F fancy type pillar taps cast copper alloy with capstan heads chromium plated screwed down high pressure with lettered hot or cold with long screwed shanks and fly nuts screwed for iron pipe and fixed in repairs 15 mm bore of pipe
S&F 5.5 mm thick sheet glass, ordinary quality, in any size of pane all as specified and directed.
S&F 4.8 mm thick sheet glass, ordinary quality, and glazing in aluminium beading with screw/rebates in square nexc 0.5 Sqm in each pane. Complete all as specified and directed.
S&F 6.3 mm thick sheet glass, ordinary quality, and glazing in aluminium beading with screw/rebates in square exc 0.5 Sqm in each pane. Complete all as specified and directed.
S&F Aluminium anodised sliding door bolt 300m long, with hasp, staple (bolt type) and fixing clip of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminium alloy .
S&F Stainless Steel but hinges 100mm size complete all as specified and directed.
S&F aluminium anodised Barrel tower bolts of extruded section, length of bolt 200mm complete all as specified and directed.
S&F aluminium anodised Barrel tower bolts of extruded section, length of bolt 150mm complete all as specified and directed.
S & F Floor door stopper 150 mm long of aluminium alloy body and tongue, anodised, with hard drawn steel spring, fixed in floor complete all as specified and directed.
S&F Extrude aluminium anodised alloy handles, fabricated type 150mm size complete all as specified and directed.
Taking down of Cement plaster on bricks or stone concrete Surface built in cement mortar including raking out joints, badding for key scrubbing down with water etc complete all as specified and directed.
M&L for rendering 15 mm thick in CM 1:6 on fair faces of brick work or concrete surfaces finishing the surface fair and even all as specified and directed.
M&L for Providing 100mm thick cement concrete 1 : 2 : 4 type B-1 using 20mm graded stone aggregate as in floor.and surface shall be finishead with broom including form work as required all as specified and directed.
M &L in repairs for machine cut kota stone slab flooring 18 to 20 mm thick as in steps, landings, floors etc laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing, mirror polishing & incl 20 mm thick screed bed in cement mortar 1:4 complete all as specified and directed.
M & L in repairs for Kota stone slab 20-25 mm thick in riser of steps, skirting, dado and pillar laid over back coat in CM 1:4 including making 02 Nos grooves in steps over & incl 20 mm thick screed bed in cement mortar 1:4 complete all as specified and directed.
S&F pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50 mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, chajjas, fixed with L or J type or cranked hook bolt in lieu of screw all as specified and directed.
M & L for preparation of newly plastered surfaces of wall, applying two coats of oil emulsion distemper over a coat of 3 mm thick wall care putty and alkali primer. Complete all as specified and directed.
M & L for complete removal of existing treatment on wall surfaces and applying a coat of (JK/ Birla) wall care putty 3mm thick on plastered surfaces, preparatory to distempering and applying two coats of oil bound distemper over a coat of wall primer.
M & L for preparation of old plastered surfaces of Ceiling , applying two coats of oil emulsion distemper over a coat of 3 mm thick wall care putty and alkali primer. Complete all as specified and directed.
S&F in repair 15 mm bore dia of pipe, brass chromium plated fancy type bib tap fixeds all as specified and directed.
S&F in repairs 15mm size Stop Valves fancy type chromium plated screwed down high pressure with crutch or butterfly handle handle screwed both ends.
S&F PVC Connections 15mm size with PTMT nuts of length 600mm all as specified and directed.
M & L for 1 mm thick galvanised steel sheet as in Valley gutters fixed with rivets or other suitable arrangements over MS brackets Trapezoidal shape of required profile with desired slope etc complete all as specified and as directed.
Supply and fix mild steel as in framed work such as grills, gratings, etc. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work con- forming to Fe.290.Gde-E-165 all as specified and directed.
M & L for Roof truss (framed), trussed, purlins, cran gangtries, rails and fastening s and heavy bracket framin (beam, tee, angle, channel or flat sections) including distance pieces, cleats etc Fe 410-W(Gde-E-250) Quality-A all as specified and directed.
M&L for preparation of new steel surfaces exc 10 cm width or girth and applying two coats of synthetic enamel paints over a coat of red oxide primer complete all as specified and directed.
M&L for machine pressed pre-cast concrete interlocking coloured paver block and shape and size conforming to IS-15658-2006 of 80mm thickness thickness M-35 Grade, glossy finished of approved colour laid over and including 25 mm thick fine sand cushion to a line and slope etc and joined complete including spreading screened river sand over surface for filling the joints with rising surface vibrator etc complete all as specified and as directed.
Removal of debries, old concrete, spoils etc exc.5 Km to outside MD land complete all as specified and as directed
Excavating in trenches, n.exc 1.5 M wide and n.exc 1.5 M in depth for foundation etc or for shafts, wells, cesspits, manholes, pier holes etc n.exc 10 Sqm on plan and n.exc 1.5 M in depth and gettging out in hard dense soils all as specified.
M&L brick work with sub class B bricks straight or curved on plan exceeding 6 m mean radius built in CM 1:6 complete all as specified and as directed.
All as per Srl item No 49 here in before but except bricks
M&L for plain cement concrete 1:4:8, type D-2 (using 40 mm graded stone agg) as in foundations, filling and mass concrete, pot holes etc complete all as specified and as directed.
M&L for plain cement concrete 1:2:4 type B-1 (using 20 mm graded stone agg) as in surface channels and drains complete all as specified and as directed.
Providing plain cement concrete type B-1, 1:2:4 (using 20 mm graded stone agg) as in lintels upto 1.5 M clear span, cills, steps, seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railing upto 60 cm in height, copings, kneelers, apex stones, bed plates, roof kerbs water troughs and the like including weathering slightly rounded or chamfered angles and throating complete all as specified and as directed.
Demolition of reinforced cement concrete of any description and in any position not otherwise specifically provided for complete all as specified and as directed.
Providing precast reinforced cement concrete type B-1, 1:2:4 (using 20 mm graded stone agg) as in landings, cover slabs (for manholes etc) chullah hoods, chajjas, water troughs, mangers, shelves and similar articles with plain face set in cement mortar 1:4 all as specified (reinforcement shall be measured & paid seperately).
M&L for mild steel TMT bars 10mm dia and over, cut to length, bent to shape required including cranking, bending spirally or hooping for columns, hooking ends and binding with and incl mild Steel wire (annealed) not less than 0.9mm dia or securing with clips all as specified.
Returning, filling in, including spreading, leveling, watering and well ramming in layers not exc 25cm in hard/dense soils complete all as specified and as directed.
Removing excavated materials (Soils) exc 3.0 KM and depositing to out side from MD Land complete all as specified and as directed.
Dismantling wrought iron or mild steel work of any description not otherwise provided for all as specified.
Cast iron work grade FG 150, unmachined, in brackets, gully traps, gratings, railing, frames, manhole covers, fire and soot doors, dampers, stop valve boxes gate stops, parts of ranges, balusters and similar articles exc 5 Kg Each complete all as specified and as directed.
Rendering 15mm thick on brick work or concrete surfaces in cement mortar 1:4 finished even and fair including mixing integral water proofing compound in the proportion as mentioned in manufacturer's instructions complete all as specified. (Water proofing compound to be measured and paid for separately).
Supply only integral water proofing compound complete all as specified.
Dismantling of cast iron or reinforced concrete drain pipes of any dia fixed to wall and taking out from trenches all as directed.
Taking down eaves gutters and PVC rainwater pipes (any size or pattern) incl all fittings, heads, shoes, bends, swanecks etc incl cleaning or refixing or removal to store (measured overall as fixed along the centre line over fittings and accessories).
S&F 160 mm bore PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to walls, ceilings or in floor etc with and including fixing clips bends elbow, shoes bends etc (Note :- Measurement shall be taken along the centre line of the pipes) complete all as specified and as directed.
S&F in repairs 160 mm dia bore PVC (SWR) bends, single/double 'Y' or 'T' with access doors any radius including fixing clips complete all as specified and as directed .
S&F in repairs 160 mm bore PVC (SWR) branch piece, single (single Y) equal or unequal all as directed.
S&F 110 mm dia PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to walls including fixing clips, bends, elbows, shoes etc complete all as specified and as directed.
S&F in repairs 110 mm bore PVC (SWR) branch piece, single (single Y) equal or unequal all as directed.
S&F sand cast type 100 mm bore cast iron soil, waste and vent pipes in any length with or without ears, with cement joints, but fixed to walls all as specified.
S&F sand cast type 100 mm bore cast iron soil, waste and vent pipes in any length with or without ears, with cement joints, laid in trenches or in floors all as specified.
S&F in repairs 100 mm bore cast iron bends (any radius), diminishing pieces or tapers (larger bore measured) all as specified.
S&F in repairs 75 mm bore cast iron floor trap, with grating including jointing to waste pipe fixed in cement concrete type B-1 (1:2:4) all as specified.
Dismantling floor, hearth or wall tiling including cement mortar bedding and disposing the rubbish to the out side of MD land complete all as specified and as directed.
M&L for 25 mm thick 1:2:4, type B-0 (using 12.5 mm graded agg) as in flooring finished even and smooth w/o using extra cement complete all as specified and directed.
M&L for Factory made machine pressed precast concrete inter locking paver block any shape and size confirming to IS-15658-2006 of 60mm thickness M-35 Grade, glossy finished of approved colour laid over and including 25 mm thick fine sand cushion to a line and slope etc and joined complete including spreading screened river sand over surface for filling the joints with rising surface vibrator etc complete all as specified.
M&L for 75 mm thick PCC (1 :3:6 ) type C-2 (using 20 mm grade aggregate ) as in sub base of floor complete all as specified and as directed.
M&L for Chequered cement concrete tiles 25cm x 25cm x 22mm thick set jointed and pointed in neat cement slurry in floors with glossy finished of approved colour in equal proportions & pigments with red and yellow colour over including 20mm thick screed bed in CM 1:6 complete all as specified and directed
M&L preparation of old decorated surfaces of walls, soffits, roof facia and applying one coat of weather proof acrylic based paint (100% acrylic) with necessary scafolding for high rise bldgs etc all as specified and directed.
Material and labour for applying one coat of OBD to old treated surfaces of wall including preparation of surface (by brooming down or steel wire brushing, scrapping down smoke soot, moulds, moss and efflorescent salts and treating oil and gresay spots) complete all as specified and directed.
M&L for preparation of newly plastered surfaces of wall and applying three coats of white wash on wall complete all as specified and directed.
M & L for Door closer hydraulically regulated, (Die Cast body) designation No. 3, universal type, suitable for door shutters of 851 to 1000 mm in width and of weight between 61 to 80 kg and fixed. Complete all as specified and directed.
M & L for 20mm thick Granite stone (of any type) work (table rubbed and polished) in steps, riser, jambs, pillar, window cills, cooking platfarm and like in cement mortar (1:4) and pointing with white cement (1:2) using marble dust with admixture of pigment to match with shade of granite. Complete all as specified and directed.
S & F stainless steel butt hinges 100 mm in size. Complete all as specifed and directed.
M&L for point wiring complete with proper colour coding using PVC insulated unsheathed multistranded copper conductor cable 1.5 sqmm size, 1100 volts (ISI marked), FRLS grade drawn through & including non metalic rigid, PVC non metallic Conduit, ISI marked, not less than 25mm dia with all accessories such as tee, bends, elbow, reducers, junction box etcfixed on wall/ceiling/truss and one run of PVC insulated unsheathed, multistranded copper conductor cable of 1.5sqmm size, 1100 volts, ISI marked, FRLS grade green colour as earth continuty conductor connected to common earth dolly with and including PVC molded box with cover plate complete all as specified and directed. Note: (a) Colour coding shall be folowed as (i) Phase- Red (ii) Neutral - Black (iii) Earth - green (b) Make of wire : Polycab/ Havells/ Gloster / Plaza (c) Switch socket measured & paid separately.
One light /Exhaust fan point controlled by one 5 amp switch
One 5A flush type switch socket point on same board board
One 5A flush type switch socket point on independent board
M&L for point wiring complete with proper colour coding using PVC insulated unsheathed multistranded copper conductor cable 2.5 sqmm size, 1100 volts ISI marked, FRLS grade drawn through and including non metalic rigid, double lock, ISI marked, not less than 25mm casing caping with all accessories such as tee, bends, elbow, reducers, junction box etcfixed on wall/ceiling/truss and one run of PVC insulated unsheathed, multistranded copper conductor cable of 2.5sqmm size, 1100 volts, ISI marked, FRLS grade green colour as earth continuty conductor connected to common earth dolly with and including PVC moulded box/hylem sheet for One 5 pin, 15A switch socket combination on the independent board complete all as specified and directed. Note: (a) Colour coding shall be folowed as (i) Phase- Red/Blue/Yellow (ii) Neutral - Black (iii) Earth - green (b) Switch socket measured & paid separately. (iv) Make of wire : Polycabl/ Plaza/ Havells/ Gloster (v) Caping casing make : Asian/ Precision/ National
M&L for point wiring (Work station for computer)complete with proper clour coding using PVC insulated unsheathed multistranded copper conductor cable 4.0 sqmm size, 1100 volts ISI marked, FRLS grade drawn through and including non metalic rigid, double lock, ISI marked, not less than 25mm casing caping with all accessories such as tee, bends, elbow, reducers, junction box etcfixed on wall/ceiling/truss and one run of PVC insulated unsheathed, multistranded copper conductor cable of 4.0sqmm size, 1100 volts, ISI marked, FRLS grade green colour as earth continuty conductor connected to common earth dolly with and including modular box with cover plate frame in any module ( Make : schneider elect/legrand mosaic/anchor ave) complete necessary electric connection for each workstation point comprising of 03 Nos 6A sockets and 01 No 15A socket on same board complete all as specified and directed. Note: (a) Colour coding shall be folowed as (i) Phase- Red (ii) Neutral - Black (iii) Earth - green (b) Make of wire : Polycab/ Havells/ Gloster Plaza
S & F in replacement of Ceiling rose, PVC/polycarbonate insulated body type, 3 teRunning Metreinal, 240 volts, 5 Ampsall as specified and directed. Make: Anchor/Roma/Legrand/Glodmodal.
S & F in repairs modular switch 1 way 6A, 1 module all as specified and directed. Make: Anchor/Roma/Legrand/Glodmodal.
S & F in repairs modular socket, 6A - 2/3 pin combined 2 modules all as specified and directed. Make: Anchor/Roma/Legrand/Glodmodal.
S & F modular switch 1 way 16A complete all as specified and directed.
S & F modular socket, 16A - 2/3 pin combined 2 modules complete all as specified and directed.
S & F exhaust fan of sweep 225 mm heavy duty type complete with self closing MS louvers, mounted in suitable opening arrangement and suitable for operation on 230 Volts single phase 50 Hz AC supply and connectin up with and including two core PVC insulated, PVC sheathed copper conductor flexible cable 24/ 0.2 mm including fixing and making connection and fixed by using 4 Nos 200 mm long 12 mm dia bolts, nuts and washers and grouted in wall in CM 1:3 completed all as specified and directed. Make: Havells/CG/ khaitan/Usha
All as per Srl item No 95 here in before but exhaust fan of sweep 300 mm
All as per Srl item No 95 here in before but exhaust fan of sweep 380 mm
All as per Srl item No 95 here in before but exhaust fan of sweep 450 mm
S & F in repair Distribution Board double door, prewired type, made out of CRCA mild steel sheet surface with insulated material like polyester or with epoxy powder coating and IP 43 & IK 09 protection surface mounting SPN 4 way, 240 volts with bus bar rating 200 Amps, dust and vermin proof suitable for incorporation of MCB’s and isolators etc complete all as directed. Make -Legrand Cat Part No. 5076 40 or equivalent in Siemens / Havells / C&S
S & F in repair Distribution Board double door, prewired type, made out of CRCA mild steel sheet surface with insulated material like polyester or with epoxy powder coating and IP 43 & IK 09 protection surface mounting TPN 8 way, 440 volts with copper bus bar rating 100 Amps for each phase with 2 neutral bar, dust and vermin proof suitable for incorporation of MCB’s etc complete all as directed. Make - Legrand cat part no 5078 87 or equivalent in Siemens /GE/ C&S NOTE FOR ITEM No. 99 to 100 : [i] MCB DBs shall be concealed in wall wherever posible including making good the surface to match with surrounding. [ii] The cost of removing old wooden box and making good of surface i.e. brick work, plastering etc is included in quated rate)
S & F in replacement of MCB 6 to 32 Amps capacity, C Curve type suitable for 240 volts AC supply, SP with over load and short circuit protection and rupturing capacity not less than 10 KA including making connection complete all as directed. Make -Legrand Cat Part No. 4086 61 or equivalent in Siemens / Havells / C&S
S & F in replacement of MCB 40 Amps capacity, C Curve type suitable for 240 volts AC supply, SPN with over load and short circuit protection and rupturing capacity not less than 10 KA including making connection complete all as directed. Make -Legrand Cat Part No. 4086 18 or equivalent in Siemens / Havells / C&S
S & F MCCB, 415 volts, Four pole, 125 Amps capacity, 16 KA, ICS = 100% ICU, with fixed Thermal- Magnetic setting including spreader terminal/ thimble of suitable size and making connections and taking down the existing unsrviceable MCCB from the panel complete all as directed. Make - Legrand cat No 4200 16 or equivalent in siemens/GE/ C&S
Supply and lay in repair cable XLPE Insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) 1100 Volts grade with stranded copper conductor of size 50sq mm 3½ core. laid in trench/ duct / along pole/wall etc including making connection complete all as directed. MAKE : Gloster/Polycab/Finolex/Havells/Plaza Note : 1. The cost of thimbles/lugs and cable gland etc is incl in quoted rate and no extra payment will be made for it.
M & L for Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required 4mm dia galvanised iron or steel wire all as specified and directed.
S&F for modular fan step regulator, 120W - 2 modular all as specified and directed. Make: Anchor/Roma/Legrand/C&S
S&F for modular type mini MCB SP 25A, 'C' series 3KA all as directed. Make : Crabtree SAP Code DCTNCSPA025/Anchor/Seimens/Roma Plus
S&F in repair of modular type shuttered socket 25 Amps 2 module 240 volts all as directed. Make : Crabtree SAP Code ACTKCXW253/Anchor/Seimens/Roma Plus
S&F in repair of modular switch 1 way 25A, 1 module all as specified and directed. Make : Crabtree SAP Code ACTKCXW251/Anchor/Seimens/Roma Plus
Taking down carefully serviceable LED 2x2 lights and refixing the same after completion of B/R work in same position complete all as specified and directed.
Disconnecting & taking down, strip opening, cleaning all parts and packing of ceiling fan of any make and size & greasing ball bearing with specified quilty grease and painting after servicing the ceiling fans & hanging in position & re-comissioning the same including making electric connection complete all as specified & directed.
S&F DLP PVC trunking syatem of size 80x50mm including flexible cover plate,joints,angle and end caps etc all as directed. Make - Legrand cat No 0104 12 or equivalent in siemens/GE/ C&S
perfect electricales
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .