Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.9 LAccepted-AOC BYE PASS N H NEAR STATE BANK OF INDIA SIDHRA JAMMU | L1 | Accepted-AOC LOWEST BIDDER | |
| 2 | L2₹1.9 L+₹2,800 (1.47%)Rejected-AOC BHAGWATI NAGAR JAMMU | L2 | Rejected-AOC NOT THE LOWEST BIDDER | |
| 3 | L3₹1.9 L+₹3,500 (1.84%)Rejected-AOC MAIN ROAD SIDHRA JAMMU | JAMMU | JAMMU AND KASHMIR | L3 | Rejected-AOC NOT THE LOWEST BIDDER | |
| 4 | L4₹2.0 L+₹5,150 (2.70%)Rejected-AOC 37 B PHASE 3 INDUSTRIAL ESTATE GANGYAL JAMMU | L4 | Rejected-AOC NOT THE LOWEST BIDDER |
| Sl No | Description | Qty | Unit | M/S K S ENGG WORKS L4 | M/S TRIKUTA ELECTRICAL & MECHANICAL WORKS L3 | GS ENGG WORKS L1 | BEE AAR ENTERPRISES L2 |
|---|---|---|---|---|---|---|---|
| 1.01 | Transportation charges for shifting of worn-out components of the VT pump of 900 VM-2 ,60 Cusecs, discharge,32.30 mtr Head VT pump of pumping Unit No 01 for repairs to the workshop by way of loading in mechanical transport from Tawi pump house and unloading the same at the workshop with the help of E.O.T crane and manual labour. Complete dismantling of bowl assembly of VT pump, servicing, greasing and re-assembling the bowl assembly including replacement of HT bolts/studs along with minor repairs to bowl assembly by way of welding worn out portion with welding electrodes. Grinding and finishing to required size. Repairs to 1 no shaft enclosing tube of VT pump by way of checking of face-to-face alignment and eccentricity developed in the enclosing tube at different off-sets with the help of dial gauge on lathe machine. Removing of eccentricity developed after welding /patching at the cracked portion with suitable M.S. welding electrodes and also welding of the cracked stiffeners of the flanges of the enclosing tubes. Repairs to 2nd line shaft of VT pump by way of rebuilding of worn-out seat portion of bearing of the Shafts. Turning, finishing, and polishing to required size. Checking of eccentricity developed at the different off-sets of the shaft during operation and removing the eccentricity developed by means of press bench. The tolerance limit be kept within the prescribed limit of +0.03 mm. Repairs to two number guide spider by way of welding of damaged/worn out seat portion of guide spider with suitable C.I. electrodes and finishing the welded portion as required making the surface even. Extraction of broken/damaged bolts by drilling and rethreading the drilled holes for fitment of counter sunk bolts. P/F of rubber pads with counter sunk bolts in all the three arms of guide spiders. The job further involves back carriage of the repaired column assembly and bowl assembly parts i.e. shaft enclosing tubes, SS line shaft and Muff coupling etc. to the site of Tawi pump house by way of loading in mechanical transport at workshop and unloading at site of Tawi pump house , Jammu with the help of manual labour .The job involves replacement of thrust pad of other 01 No.s guide spider- (03 Nos). Assembling and lowering of extracted VT pump and column assembly involves complete wiping ,cleaning repaired parts, lowering of complete bowl assembly , column assembly in proper sequence by fitting of column pipes and fitting further, lowering fitting of shaft enclosing tube along with line shaft one by one to discharge head and Tee joint fitting with rising main of 36” dia. P/F of consumables items during lowering of the VT pump like line shaft rubber bearing 7 Nos.( 5 no Provided by the Deptt. and rest by the firm) bottom rubber bearing 1No., HT column bolts with nuts 120 x20 mm (reputed make) 18 Nos., HT shaft enclosing tube bolts with nut 110x16 mm 22 Nos., HT bolts with nuts 110x25 mm (reputed make) 16 Nos., HT bolts 65x16mm 15 Nos. , HT bolts 45x16 mm 12 Nos., HT Allen key bolts 40x12 mm 15 Nos., spring washers-16mm 30 nos., spring washers 12mm 24 Nos., fire fly sheet 1/32” 6 kg, fire fly sheet 1/16” 7.5 kg., rubber insertion sheet 1/18” 12 kg, gland packing ¾” 2kg, hacksaw blade double edge 6 Nos., HT bitumen tape roll, emery cloth 7 mtr. Grease -7 kg and servo system 46 -15 litres for topping of motor ( servo system46, provided by Deptt.) Fitting of pump and motor half coupling, checking alignment of pump and motor using dial gauge, making all the electrical connection, tightening bolts, providing of gasket, electrical thimbles and then testing on full load. Skilled person shall be provided by the firm for extraction /fitting /assembling of parts during lowering of VT pump. Complete job includes cost of materials and labour charges. | 1 | Job | 1,61,850 ₹1,61,850 | 1,61,000 ₹1,61,000 | 1,58,400 ₹1,58,400 Lowest | 1,59,500 ₹1,59,500 |
| 1.02 | Replacement of damaged Components of 01 No incomer VCB panel at Tawi Pump House Jammu by way of checking of breaker and racking out Vacuum Circuit Breaker from chamber, cleaning the HT panel using cotton rags, cleaning Chemical such as CRC spray removing, dust, carbon deposits at contacts, closing and shunt trip coil 110 V DC, , auxiliary switch, anti-pumping relay and auxiliary contactor 230 V AC -01 no. by way of extraction of damaged parts and providing and fitting of new parts of same specifications. Complete servicing of Vacuum circuit breaker, checking IR value between earth and all phases and then across all phases and testing it at test position, taking out CT/PT unit from housing after disconnecting HT supply from Receiving station and discharging contacts and complete servicing of CT/PT by cleaning insulators by removing dust, removing carbon deposits at all contacts points, checking fuses and replace blown up/overheated fuses. Fitting CT/PT unit at its place. Checking primary and secondary connection for tightness. Checking earthing of CT/PT. Measuring insulation resistance. Providing and fitting of 01No Voltmeter with Selector switch 0-8KV SIF 96, 6.6 KV/110v in place of damaged one. Replacement of damaged HRC fuses, indicating lamps, push button, and toggle switch of space heater. Providing and fitting of new space heater in place damaged. Calibration of all protection relay with the help of secondary injecting apparatus and programming Overcurrent earth fault relay. | 1 | Job | 34,000 ₹34,000 | 33,200 ₹33,200 | 32,300 ₹32,300 Lowest | 34,000 ₹34,000 |
Tender Value
Refer Docs
EMD Value
₹3,950
Closing Date
13 Oct 2025, 3:00 pmClosed
Executive Engineer Mech Div. RTIC Jammu
Office of Executive Engineer Mech Div. RTIC Jammu
Extraction, checking, repair /servicing of 01 no (Unit no. 01) VT pump installed at Tawi Pump House, Jammu (filled with mud, silt and debris during flash flood) along with repair/servicing of 01 no incomer (main supply) VCB panel.
2025_IFC_290714_1
e nit 25 of 2025-26 dt 04.10.2025
Open Tender
Electrical and Maintenance Works
Item Rate
21 days
Office of Executive Engineer Mech Div. RTIC Jammu
Please refer Tender documents.
8 documents required · 8 mandatory
₹200
Yes
Executive Engineer Mech Div. RTIC Jammu
₹3,950
Yes
Office of Executive Engineer Mech Div. RTIC Jammu
16 Oct 2025
4 Oct 2025
14 Oct 2025
4 Oct 2025
13 Oct 2025
7 Oct 2025
6 Oct 2025
Amount
Transportation charges for shifting of worn-out components of the VT pump of 900 VM-2 ,60 Cusecs, discharge,32.30 mtr Head VT pump of pumping Unit No 01 for repairs to the workshop by way of loading in mechanical transport from Tawi pump house and unloading the same at the workshop with the help of E.O.T crane and manual labour. Complete dismantling of bowl assembly of VT pump, servicing, greasing and re-assembling the bowl assembly including replacement of HT bolts/studs along with minor repairs to bowl assembly by way of welding worn out portion with welding electrodes. Grinding and finishing to required size. Repairs to 1 no shaft enclosing tube of VT pump by way of checking of face-to-face alignment and eccentricity developed in the enclosing tube at different off-sets with the help of dial gauge on lathe machine. Removing of eccentricity developed after welding /patching at the cracked portion with suitable M.S. welding electrodes and also welding of the cracked stiffeners of the flanges of the enclosing tubes. Repairs to 2nd line shaft of VT pump by way of rebuilding of worn-out seat portion of bearing of the Shafts. Turning, finishing, and polishing to required size. Checking of eccentricity developed at the different off-sets of the shaft during operation and removing the eccentricity developed by means of press bench. The tolerance limit be kept within the prescribed limit of +0.03 mm. Repairs to two number guide spider by way of welding of damaged/worn out seat portion of guide spider with suitable C.I. electrodes and finishing the welded portion as required making the surface even. Extraction of broken/damaged bolts by drilling and rethreading the drilled holes for fitment of counter sunk bolts. P/F of rubber pads with counter sunk bolts in all the three arms of guide spiders. The job further involves back carriage of the repaired column assembly and bowl assembly parts i.e. shaft enclosing tubes, SS line shaft and Muff coupling etc. to the site of Tawi pump house by way of loading in mechanical transport at workshop and unloading at site of Tawi pump house , Jammu with the help of manual labour .The job involves replacement of thrust pad of other 01 No.s guide spider- (03 Nos). Assembling and lowering of extracted VT pump and column assembly involves complete wiping ,cleaning repaired parts, lowering of complete bowl assembly , column assembly in proper sequence by fitting of column pipes and fitting further, lowering fitting of shaft enclosing tube along with line shaft one by one to discharge head and Tee joint fitting with rising main of 36” dia. P/F of consumables items during lowering of the VT pump like line shaft rubber bearing 7 Nos.( 5 no Provided by the Deptt. and rest by the firm) bottom rubber bearing 1No., HT column bolts with nuts 120 x20 mm (reputed make) 18 Nos., HT shaft enclosing tube bolts with nut 110x16 mm 22 Nos., HT bolts with nuts 110x25 mm (reputed make) 16 Nos., HT bolts 65x16mm 15 Nos. , HT bolts 45x16 mm 12 Nos., HT Allen key bolts 40x12 mm 15 Nos., spring washers-16mm 30 nos., spring washers 12mm 24 Nos., fire fly sheet 1/32” 6 kg, fire fly sheet 1/16” 7.5 kg., rubber insertion sheet 1/18” 12 kg, gland packing ¾” 2kg, hacksaw blade double edge 6 Nos., HT bitumen tape roll, emery cloth 7 mtr. Grease -7 kg and servo system 46 -15 litres for topping of motor ( servo system46, provided by Deptt.) Fitting of pump and motor half coupling, checking alignment of pump and motor using dial gauge, making all the electrical connection, tightening bolts, providing of gasket, electrical thimbles and then testing on full load. Skilled person shall be provided by the firm for extraction /fitting /assembling of parts during lowering of VT pump. Complete job includes cost of materials and labour charges.
BEE AAR ENTERPRISES (BID ID -2590084)
M/S TRIKUTA ELECTRICAL & MECHANICAL WORKS (BID ID -2589949)
M/S K S ENGG WORKS (BID ID -2590197)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .