Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹4.5 CrAccepted-AOC | ₹4.5 Cr | 1 | Accepted-AOC L1 |
| 2 | 2₹4.6 Cr+₹8.6 L (1.93%)Rejected-Finance GOA | NORTH GOA | GOA | 403524 | ₹4.6 Cr+₹8.6 L (1.93%) | 2 | Rejected-Finance 2nd Lowest |
Tender Value
₹4.3 Cr
EMD Value
₹8.5 L
Closing Date
11 Sept 2023, 3:00 pmClosed
Executive Engineer
Paryatan bhavan patto Panaji
Upgradation/ beautification of tourist places in Quepem Taluka. Regarding beautification and Development of Shantadurga Bhumipurush Sapthakoteshwar temple complex Fatorpa
2023_GTDCL_10651_1
GTDC/PC/EE/2023-24/e-20
Open Tender
Civil Works
Item Rate
180 days
Fatorpa Quepem
Please refer Tender documents.
6 documents required · 6 mandatory
₹15,000
₹8.5 L
14 Mar 2024
19 Aug 2023
12 Sept 2023
19 Aug 2023
11 Sept 2023
19 Aug 2023
Amount
TRANSPORTATION AND CARRIAGE OF MATERIALS (A) By tipper truck including loading, unloading and stacking (2km) ( ii ) Earth
Clearing grass and removal of rubbish upto a distance of 50 m outside the periphery of the area
Earthwork in excavation by mechanical means (hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sq.m on plan) including disposal of excavated earth lead upto 50 m and lift upto 1.5m disposed earth to be leveled and neatly dressed including providing barricading, danger lighting guarding as directed in : a:All kinds of soil
Earthwork in excavation by mechanical means (hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sq.m on plan) including disposal of excavated earth lead upto 50 m and lift upto 1.5m disposed earth to be leveled and neatly dressed including providing barricading, danger lighting guarding as directed in b: All types of Ordinary rock including all types of laterite rock, blasting prohibited
Earthwork in excavation by mechanical means (hydraulic excavator)/manual means in foundation pipeline trenches drain (not exceeding 1.5 m in width or 10 sq.m. on plan) including dressing of sides and ramming of bottoms, lift upto 1.5 m including getting out the excavated soil and disposal of surplus excavated soil as directed within a lead of 50 m. b: All types of Ordinary rock including all types of laterite rock, blasting prohibited
Refilling the pipeline/foundation trenches plinth sides, foundation etc. with available excavated earth in layers not exceeding 20 cm depth consolidating each layer ramming and watering lead upto 50 M and all lifts and disposal of surplus earth as directed by Engineer in Charge.
Brick work using common burnt building bricks in cement mortar 1:3 (1 cement : 3 coarse sand) with bricks of class designation 75 kg/ cm2 (wire cut bricks) (b) In superstructure upto floor five level.
Rubble packing with hard laterite stone under floors including watering ramming and consolidating etc. in pipeline trenches and other foundations complete.
Laterite masonry in neatly dressed stones of size as specified in cement mortar 1: 4 (1 cement : 4 coarse sand) in foundation and basement.
Laterite masonry in neatly dressed stones of size as specified in cement mortar 1: 4 (1 cement : 4 coarse sand) in foundation and basement. Extra for laterite masonry in all sizes in superstructure from floor I level upto floor V level.
Providing and laying in position cement concrete 1:2:4 (1 cement : 2 coarse sand: 4 graded granitic or basaltic stone aggregate 20mm nominal size) excluding cost of centering, shuttering and finishing : a:All works upto plinth level
Providing and laying in position cement concrete 1:2:4 (1 cement : 2 coarse sand: 4 graded granitic or basaltic stone aggregate 20mm nominal size) excluding cost of centering, shuttering and finishing : b:In retaining walls , return walls(any thk) including attached pilasters, columns, piers, abutments, pillars, posts, struts, buttresses, string or lacing courses, parapets, coping bed blocks, anchor blocks, plain window sills, fillets etc, upto floor five level.
Providing and laying in position (1:11/2:3) Reinforced cement conrete excluding the cost of centering, shuttering, finishing and reinfrocement (1 cement: 1½ coarse sand:3 graded stone agg 20mm nominal size) a:All works upto plinth level
Providing and laying in position (1:11/2:3) Reinforced cement conrete excluding the cost of centering, shuttering, finishing and reinfrocement (1 cement: 1½ coarse sand:3 graded stone agg 20mm nominal size) b:In walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and structs etc. upto floor five level
Providing and laying in position (1:11/2:3) Reinforced cement conrete excluding the cost of centering, shuttering, finishing and reinfrocement (1 cement: 1½ coarse sand:3 graded stone agg 20mm nominal size) c: In beams, suspended floors, roofs having slope upto 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases upto floor five level
Centering & shuttering including Strutting, Propping & removal of forms for : i:Foundations, Footings, Bases for Columns
Centering & shuttering including Strutting, Propping & removal of forms for : ii: Vertical surfaces such as retaing walls, return walls, Partitions, walls (any thickness) including attached Pilasters, Buttresses, Plinth and string courses, Fillets and the like
Centering & shuttering including Strutting, Propping & removal of forms for : iii:Columns, Piers, Pillars, Aburments, Posts and struts (square rectangle polygon in plan)
Centering & shuttering including Strutting, Propping & removal of forms for : iv:Sides and Soffits of beams, Beam Haunchings, Cantilever, Girders, Bressumers and Lintels plinth beams not exceeding 1m in depth
Centering & shuttering including Strutting, Propping & removal of forms for : xii:Suspended floors, roofs landings, shelves & their supports
Centering & shuttering including Strutting, Propping & removal of forms for sloping or battering surface (slabs, beams, louvers, etc) including folded plates i) Where inclination to the horizontal does not exceed 30° requiring shuttering on the underside only + Extra to be added for additional height in centering, shuttering where ever required with adequate bracing, propping etc. including cost of de- shuttering and de-centering at all levels, over a height of 3.5m, for every additional height of 1m or part thereof. (Plan area to be measured) Suspended floors, roofs, landings, beams and balconies (plan area to be measured)
Centering & shuttering including Strutting, Propping & removal of forms for sloping or battering surface (slabs, beams, louvers, etc) including folded plates ii) Where inclination to the horizontal exceeds 30° requiring shuttering on the underside & upperside if required (Only area of underside shall be measured for payment) + Extra to be added for additional height in centering, shuttering where ever required with adequate bracing, propping etc. including cost of de- shuttering and de-centering at all levels, over a height of 3.5m, for every additional height of 1m or part thereof. (Plan area to be measured) Suspended floors, roofs, landings, beams and balconies (plan area to be measured)
Providing TMT steel reinforcement bars of (SAIL, TATA. VIZAG, JSW Steel Ltd.) ) (Confirming to IS 1786 of 1986) for RCC work (conforming to I.S. 1786 of 1986) including bending, binding & placing in position in all the floors along with the factory made precast concrete cover blocks of specified sizes whose compressive strength is not less than that of surrounding concrete in the structural member.
Providing woodwork in frames of doors, windows, clerestory windows trusses & other frames wrought framed and fixed in positon. b: Second class Indian teak wood
Providing and fixing 50 mm thick panelled glazed or panelled and glazed shutters for doors, windows and clerestory window including anodized aluminium butt hinges with necessary screws: b:Second class Indian teak wood
Providing flat iron hold fast 40 cm including fixing to frame with 10 mm dia bolts, nuts and wooden plugs and embeded in cement concrete block 30 x 10 x 15 cm 1:3:6 mix (1 cement: 3 coarse sand: 6 stone aggregate 20 mm nominal size. b: 40 x 3 mm flat iron hold fast, 15 cm long
Providing and fixing bright finished brass door latch with necessary screws etc complete a:300x 16 x 5 mm
Providing and fixing brass hydraulic door closer of make Everest universal 68 or equivalent with necessary screws and fittings complete.
Providing & fixing chromium plated brass tower bolts (barrel type) with necessary screws complete. a:250 x 10 mm
Providing and fixing chromium plated brass handle with necessary screws etc. complete. a:125mm
FRP (Fiber Reinforced Polymer) Frames with Wood Finish Manufacture, Supply and Installation (with anchor fastener) of EPEE or equivalent Goan make FRP (Fiber Reinforced Polymer) Frame of cross section as per options below with right angle joint and FRP (Fiber Reinforced Polymer) laminate made from 450 grams per sq.mts (gsm) chop strand glass fiber (matt) and unsaturated polyester resin with viscosity range of 400/450 centipoises per second (cps). The core of frame would be filled with seasoned wood as infill material. The slot of frame for door resting will be of suitable width so as to take specified thickness door. The frame will be water proof as well as mild acid/ alkali resistant manufactured in an ISO 9001- 2015 certified company. Accessories:i) S. S. Hinges 4” - 3 Nos, ii) S. S. Latch - 1 No, iii) Tower Bolt 5” - 2 Nos, iv) Handle 5” - 2 Nos, Shutter Thickness : a) 30mm
Providing & fixing Stainless Steel tubular lever D- Type mortise handles with round/Square nose, 24mm Mortise/sash lock body & Strike plate (all SS Finish), Pin cylinder 60mm with one side key and other side knob/thumb turn with necessary screws etc. complete
Providing and fixing in position S.S. hand rail in main stair case, and landing as per approved design shown in the drawing including bending handrail pipe to proper shape in curves with specials, etc. complete.
Providing and fixing anodized aluminium shutters in accordance with the specification annexed with Goa schedule of Rates (2004) Vol & II including all taxes, transportation, scaffolding and handling etc. complete as per direction of the Engineer-in-charge: windows with two sliding shutters using 18 mm series shutters section. c:Figured glass
Providing and fixing anodized aluminium shutters in accordance with the specification annexed with Goa schedule of Rates (2004) Vol & II including all taxes, transportation, scaffolding and handling etc. complete as per direction of the Engineer-in-charge: Adjustable louvered windows. c:Figured glass
Steel work in built up tubular (round, square or rectangular hollow tubes etc.) (Square Hollow Section (SHS) IS4923 /Rectangular Hollow Section (RHS) IS4923/ Circular Hollow primer, including welding and bolted with special shaped washers etc. complete.(Min Yeild Stress 310 Mpa)) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steelSection (CHS) IS1161 closed Structural Steel of (SAIL, TATA. VIZAG, JSW ,APOLLO Steel Ltd.) make
Providing and fixing stainless steel (Grade 304) railing made of Hollow tubes, channels, plates etc.with hairline finish, including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer, ( for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.).
Precast plain cement chequered tiles 22 mm thick of required shades laid in floors, treads of steps and landing on 20 mm thick bed of Cement mortar 1:4 (1cement : 4 coarse sand) jointed with neat cement slurry mixed with pigment to match the shade of tiles including rubbing and cleaning etc. complete. a:Light shade using white cement
Providing and fixing coloured ceramic tiles spartek or equivalent of 12 " x 12" (399x150 mm cut size) 6 mm thick in skirting and dados on 12 mm thick cement plaster 1:3 (1 cement : 3 coarse sand) and jointed with cement slurry complete.
Providing 20mm thick marble slab to urinal partitions wlyh cement atc. Complete
Providing and laying jet black mirror polish granite flooring and dado over 20mm thick base of cement mortar 1:4 laid over and jointed with cement slurry including rubbling complete Granitic slab (jet blck with mirror polish) 20 mm thick add q0% wastage 1.00
Providing 25 mm thick cuddapah slabs machine cut and polished on either side in partitions including making necessary grooves in the wall and fixing with cement mortar, complete as directed by the engineer-in-charge
Precast plain Cement Tacktiles 32mm thk of required shade in floors, treads of steps and landing laid on 25mm bed of cement mortar 1:4 (1cement: 4 coarse sand) jointed with neat cement slurry with pigment to match the shade of tiles including rubbing and polishing complete.
Providing and laying factory made Shot blasted cement concrete interlocking paver block of minimum M35 grade made by heavy duty block making machine with strong vibratory compaction and of aprpoved size and design / shape laid in 50 mm thick compacted bed of coarse sand, filling the joints with coarse sand, etc. all complete as per the direction of Engineer.- in I, Wave, Rectangular, Square etc. shapes. The products should comply to IS 15658:2006 and manfucatured by ISO9001: 2008 certified plant. The shot blasting should be done using 0.4-0.5mm dia steel shots with a speed of 3200 rpm. a)60 mm thick in all colours except grey
Providing and laying factory made Shot blasted cement concrete interlocking paver block of minimum M35 grade made by heavy duty block making machine with strong vibratory compaction and of aprpoved size and design / shape laid in 50 mm thick compacted bed of coarse sand, filling the joints with coarse sand, etc. all complete as per the direction of Engineer.- in I, Wave, Rectangular, Square etc. shapes. The products should comply to IS 15658:2006 and manfucatured by ISO9001: 2008 certified plant. The shot blasting should be done using 0.4-0.5mm dia steel shots with a speed of 3200 rpm. b) 60 mm thick in Grey colour
Providing and laying flamed finish Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer : Flamed finish granite stone slab. c: Elite Brown
Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels. Granite of any colour and shade, area of slab over 0.50 sqm a: Jet Black
Providing and fixing colour coated galvulium roofing sheets of 0.5mm thickness including all the accessories (TATA make) but excluding the cost of purlins, rafters, trusses, charge.flashings etc. complete as per the directions of the Engineer in
Providing & Fixing of Metal Tile Ceiling System comprising of Tile of 600mm wide and 600mm long manufactured of 0.6mm thick Aluminium Clip-in perforated 2.5mm dia 5.5mm c/c. The Tile shall be manufactured on advanced equipment, which includes several levelling stages in the manufacturing process. Tile ends shall be raised with pips and stops to ensure positive engagement into the spring to enable for de-mounting of individual panels. The Tile sides shall be sufficiently high to ensure a minimum deflection across the length of Tile. All Tiles shall be bevelled edged. The Tile shall be polyester based, powder coated in White Colour. Tile shall be clipped into clip in profile of 0.5mm thick G.I. The clip in profile shall be supported from slab by means of rigid suspension of 4mm G.I. Rod, Hold on Clamp with Clip. Acoustic Felt: Non-woven felt made of glass-reinforced fibreglued over the perforation for sound absorption.
12mm cement plaster 1:4 (1 cement : 4 fine sand)
20mm cement plaster 1: 3 (1 cement : 3 fine sand)
6mm cement plaster to ceiling 1: 3 (1 cement : 3 fine sand)
Extra for providing and mixing water proofing material proportion recommended by the manufacturers. :12mm cement plaster 1: 3 (1 cement : 3 sand)
18mm cement plaster in two coats under layer 12mm thick cement plaster 1:5 ( 1 cement : 5 coarse sand) and top layer 6mm thick with cement plaster 1: 3 (1 cement : 3 coarse sand) finished with sponge.
12mm thick plain cement mortar bands in cement mortar 1:4 (1 cement: 4 fine sand) 1 meter long, 1 cm wide
Pointing on stone work, with cement mortar 1: 3 (1 cement: 3 fine sand) c:Raised and cut pointing
Painting two or more coats (excluding priming coat) with superior quality ready mixed paint for steel work of approved brand & manufacture in all shades on new work to give an even shade.
Painting (two or more coats) with synthetic enamel paint of approved brand and manufacture in all shade or new work over and under coat of suitable shade with ordinary paint of approved brand and manufacture to give an even shade
Wall painting (two or more coats) with plastic emulsion paint of approved brand and manufacture on new work to give an even shade.
Painting three or more coats with acryllic exterior paint of approved brand and manufacture (such as weather shield,APEX) including applying one coat of cement primer and one coat of surface treatment etc. complete.
Providing and applying white cement based putty of average thickness 1.00mm of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.
Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430 x 260 x 350 mm and 340 x 430 x 265 mm sizes respectively with pvc automatic flushing cistern with fittings, R.S. or C.I. brackets, standard size galvanised steel flush pipe and spreaders with brass unions & G.I. clamps complete, including painting of cister and fittings, cutting and making good the walls and floors where required. b: Range of three urinal basins with 10 litres pvc. automatic flushing cistern .
Providing and fixing vitreous china wash basin with RS or C.I. brackets painted white, 15 mm C.P. brass pillar taps C.P. brass chain with rubber plug 32 mm C.P. brass waste of pattern, 32 mm diameter M.I. or C.P. brass trap and union complete, including cutting and making good the walls where required. b:Flat back wash basin size 630x 450mm with a single 15 mm C.P. brass pillar taps.
Providing and fixing 600 x 450 mm bevelled edge mirror of superior glass (of approved quality) complete with 6 mm thick asbestos sheet ground fixed to wooden cleats with C. P. brass screws and washers.
Providing & fixing c.p. brass towel rail complete with C.P. brass brackets fixed to wooden cleats with C. P. brass screws b:600 x 20 mm size
Providing and fixing toilet paper holder : a:C.P. brass
Providing & fixing liquid soap container with C.P. brass lid and brackets fixed to wooden cleats with C. P. brass screws a: Glass container
Providing and fixing white vitreous china type water closet squatting pan (european type w.c. pan) with flush valve Nelson/ similar) fully chromium plated with stop cock wall flanges flush pipe or elbow and vaccu.m breaker coupling etc. including cutting making good the walls and floors where required.
Providing and fixing white vitreous china water closet squatting pan (Indian type w.c. pan) with flush valve Nelson/ similar) fully chromium plated with stop cock wall flanges flush pipe or elbow and vaccu.m breaker coupling etc. including cutting making good the walls and floors where required.
Providing and fixing brass stop cock (heavy) of approved quality : a:15 mm nominal bore
Providing and fixing brass stop cock (heavy) of approved quality : c:25 mm nominal bore .
Providing and fixing brass stop cock (heavy) of approved quality : d: 32 mm nominal bore
Providing and fixing brass full way valve (heavy) duty with wheel of approved quality : d: 32 mm nominal bore
Providing and fixing ball valve (brass) of approved quality a:High pressure with P.V.C. floats, 3: 25mm nominal bore
Providing and fixing non-return valve of approved quality : a:25 mm nominal bore
Providing and fixing non-return valve of approved quality : b: 32 mm nominal bore
Providing and placing on terrace roof of floor two (1st flor roof single piece rotational moulded polythene water storage tank having I S I mark and conforming to I S 12701; 1996. c:1000 lit. capacity
Providing and fixing square-mouth S.W. gully trap grade ‘A’ complete with c.i. grating brick masonry chamber and water tight C.I. cover with frame of 300 x 300 mm size (inside the weight of cover to be not less than 4.53 kg). And frame to be not less than 2.72 kg as per standard design : b:150 x 100 mm size –P or S type (for Basin)
Constructing brick masonry manhole or inspection chamber with second class bricks in cement mortar 1:5 (1 cement :5 fine sand) R.C.C. top slab with 1:2:4 mix (1 cement: 2 coarse sand ;4 graded stone aggregate 20mm nominal size foundation concrete 1:2:4 mix (1 cement ;2 coarse sand :4 graded stone agrregate 40mm nominal size) inside plastering 12 mm thick with cement mortar 1:3 (1 cement :3 coarse sand) finished with a floating coat of neat cemetn and making channels in cement concrete 1:2:4 mix (1 cement :2 coarse sand :4 graded stone aggregate 20 mm nominal size) neatly finished complete as per standard design. d: Inside size 60 x 60cm and 60cm deep including C.I. cover with frame (light duty) 455x610mm internal diameter total weight of cover and frame to be not less than 38 kg. (weight of cover 23 kg).
Providing and fixing rigid PVC S.W.R. (soil, waste & rain water drainage pipes of approved including lubricant etc. complete (single/double) socketed: a:110 mm dia
Providing and fixing rigid PVC S.W.R. (soil, waste & rain water drainage pipes of approved including lubricant etc. complete (single/double) socketed: b:75 mm dia
Providing and fixing nahani trap of rigid PVC (approved make ) for S.W.R. pipes including lubricating etc complete, without door : a: 110 mm dia
Providing and fixing R.P.V.C. vent cowl: a:110 mm dia
Providing and fixing NICKEL chrome plated copper alloy Fancy two way long body bib cock with wall flance Jaquar make or equivalent. Confirming to IS 8931;1993, a:15mm nominal bore
Providing and fixing NICKEL chrome plated copper alloy Fancy concealed stop cock with slinding flance 15 mm Jaquar make or equivalent. Confirming to IS 8931;1993, a:15mm nominal bore
Providing and fixing chlorinated ployvinyl chloride (CPVC) pipes confirming to IS:15778, having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings including fixing the pipes with clamps at 1 mt. spacing. This includes jointing of pipes and fittings with one step CPVC solvent cement and testing of joints complete as per direction of the Engineer-in-charge. Concealed work (medium duty SDR 13.5 pipe) including cutting chases and making good the walls etc. a:15 mm dia nominal outer dia pipes.
Providing and fixing chlorinated ployvinyl chloride (CPVC) pipes confirming to IS:15778, having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings including fixing the pipes with clamps at 1 mt. spacing. This includes jointing of pipes and fittings with one step CPVC solvent cement and testing of joints complete as per direction of the Engineer-in-charge. Concealed work (medium duty SDR 13.5 pipe) including cutting chases and making good the walls etc. c: 25 mm dia nominal outer dia pipes.
Providing and fixing chlorinated polyvinyl chloride (CPVC) pipes confirming to IS: 15778 having thermal stability for hot and cold water supply includng all CPVC plain and brass threaded fittings CPVC solvent cement, trenching, refilling and testing of joints complete as per firection of the Engineer in charge.(External work (heavy duty SDR 11 pipe) ,b:20 mm nominal outer dia pipes.
Providing and fixing chlorinated polyvinyl chloride (CPVC) pipes confirming to IS: 15778 having thermal stability for hot and cold water supply includng all CPVC plain and brass threaded fittings CPVC solvent cement, trenching, refilling and testing of joints complete as per firection of the Engineer in charge.(External work (heavy duty SDR 11 pipe) , c: 25mm nominal bore
Providing and fixing chlorinated polyvinyl chloride (CPVC) pipes confirming to IS: 15778 having thermal stability for hot and cold water supply includng all CPVC plain and brass threaded fittings CPVC solvent cement, trenching, refilling and testing of joints complete as per firection of the Engineer in charge.(External work (heavy duty SDR 11 pipe) d:32 mm nominal outer dia pipes.
Providing & fixing G.I. pipes complete with G.I. fittings including trenching & re-filling etc. (external work). e:40 mm nominal bore
Fixing water meter & stop cock in G. I. Pipe line including cutting & treading the pipe and making long screw etc. complete (cost of water meter and stop cock to be paid separately)
Providing and fixing C.P. brass shower rose with 15 or 20 mm. Inlet:, b:150 mm diameter.
Supply of Ibferential, dry dial. Type domestic water meter for horizontal installation, duly sealed against tampering with coupling at both ends having pulse output facility compatible for autromatic reading system conforming to IS:779-1994 and iSO 4064 and bearing EECMark along with test certificate from FCRI or NABL as desired by the department, c:25mm in dia
Constructing soak pit 1.20m x 1.20m x1.20m filled with laterite stone aggregate 125 to 180 mm including S.W. drain pipe 100 mm diameter and 1.2m. long complete as per standard design.
Providing and fixing rigid PVC bend of required degree (of approved make) for S.W.R. drainage pipes of approved including lubricating., a:110 mm dia
Providing and fixing rigid PVC bend of required degree (of approved make) for S.W.R. drainage pipes of approved including lubricating. b:75 mm dia
Providing and fixing rigid PVC bend of required degree (of approved make) for S.W.R. drainage pipes of approved including lubricating etc complete bend with door : , c:110 mm dia
Providing and fixing single tee of rigid PVC (approved make) for S.W.R. pipes including lubricating etc. complete, without door: a:110 mm dia
Providing and fixing single “Y” of rigid PVC (approved make ) for S.W.R. pipes including lubricating etc complete, without door : a:110 mm dia
Providing and fixing NICKEL chrome plated copper alloy Fancy BIB Cock Short Body Jaquar make or equivalent. Confirming to IS 8931;1993, a:15mm nominal bore
Providing and fixing NICKEL chrome plated copper alloy Fancy long body bib cock with wall flance Jaquar make or equivalent. Confirming to IS 8931;1993, a:15mm nominal bore
Providing and fixing NICKEL chrome plated copper alloy Fancy concealed stop cock with slinding flance 15 mm Jaquar make or equivalent. Confirming to IS 8931;1993 , a:15mm nominal bore
Providing and fixing NICKEL chrome plated copper alloy Fancy BOTTLE TRAP ECONOMY TYPE 32MM Jaquar make or equivalent. Confirming to IS 8931;1993
Providing and fixing chlorinated ployvinyl chloride (CPVC) pipes confirming to IS:15778, having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings including fixing the pipes with clamps at 1 mt. spacing. This includes jointing of pipes and fittings with one step CPVC solvent cement and testing of joints complete as per direction of the Engineer-in-charge. Internal work exposed on wall (Medium duty SDR 13.5 pipe). a:15 mm outer dia CPVC pipe
Providing and fixing chlorinated ployvinyl chloride (CPVC) pipes confirming to IS:15778, having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings including fixing the pipes with clamps at 1 mt. spacing. This includes jointing of pipes and fittings with one step CPVC solvent cement and testing of joints complete as per direction of the Engineer-in-charge. Internal work exposed on wall (Medium duty SDR 13.5 pipe). b:20 mm outer dia CPVC pipe
Providing and fixing Hand Shower (Health Faucet) with 8mm dia, ABS/brass body with double lock 1.00m long Flexible tube (Brass plated stainles steel flexible hose) and wall hook of approved quality confirming to IS standards.
Providing and fixing ASTM UPVC pipe, conforming to ASTM 2467 with ISO 14001, including all UPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step UPVC solvent cement and testing of joints complete as per direction of Engineer. Internal work - Exposed on wall.SCH-80(blue)/(white), a:20mm outer dia.
Providing and fixing ASTM UPVC pipe, conforming to ASTM 2467 with ISO 14001, including all UPVC plain & brass threaded fittings, including jointing of pipes & fittings with one step UPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer. External work. a:20mm outer dia.
Extra for providing opening of required size & shape for wash basin/ kitchen sink in kitchen platform, vanity counter and similar location in marble/Granite/Cuddapah stone work, including necessary holes for pillar taps etc. including moulding, rubbing and polishing of cut edges etc. complete.
Providing anti – termite treatment to buildings conforming to I.S.S. 6113 part II 1971 (revised) including adopting precautions for health hazards and safety measures as required therein with the cost of all materials, chemicals, plants, equipments required for the treatment and furnishing a guarantee for a minimum period of 10 years from the date of completion including eradicating any infestation of termite free of cost during the guaranty period complete. (Thepayment will be made on plinth of the building). , a:Pre-construction
Providing anti – termite treatment to buildings conforming to I.S.S. 6113 part II 1971 (revised) including adopting precautions for health hazards and safety measures as required therein with the cost of all materials, chemicals, plants, equipments required for the treatment and furnishing a guarantee for a minimum period of 10 years from the date of completion including eradicating any infestation of termite free of cost during the guaranty period complete. (Thepayment will be made on plinth of the building). , b:Post construction
Fabrication and fixing of Aluminium composite panel cladding with thick 3mm/ 0.25mm ACP sheets, aluminium framework, with 50 X 25 X1.2 mm thick sections. Silicon sealants etc. including accessories complete.
Supplying and fixing Pre-cast cement concrete kerb-stones(factory made,the factory should be ISO certified and registered under Dirctorate of Industries, Govt. of India) of M-20 with 20 mm nominal size granitic/basaltic aggregate properly consolidated by mechanical plat-form and vibrators with smooth finish including fixing at site complete as per specification. (a) Size 30 cm L x 50 cm H x 15 cm T
Supply at site of work well decayed farmyard manure, from any available source approved by the engineer-in charge including screening and stacking as per MORTH Specification 308.2
Providing and fixing weepholes with rigid PVC make laid in position with a required slope and level while layingpipes of approved the concrete of retaining wall,wing wall and earth retainig structure complete as directed by the Engineer in charge ,A:110 mm dia
Making lawns including ploughing and breaking of clod, removal of rubbish, dressing and supplying doobs grass roots and planting at 15 cm apart, including supplying and spreading of farm yard manure at rate of 0.18 cum per 100 sqm. as per MORTH Specification 307
Red oxide plaster for roofing slab (upto 5m height) with top layer of 6 mm thick plaster of cement mix using 3.5 kg of red oxide of iron per 50 kg of cement in mortar 1:3 (1 cement: 3 coarse sand) finished with a floating coat of cement red oxide mix of same proportion in mangalore tile or similar design as directed by the engineer-in-charge.
Providing and placing 1.5HP pumpset including fixing suction pipe of approved make approved by engineer incharge
Providing and fixing of CNC Cut Acrylic sheet on ACP cladding having a support member of Aluminium material and supporting fixtures. This is including lead,lift,transportation,tools,plants,etc. complete.
Providing and fixing of Banner made up of Vinyl Flex having size as per site requirement with transportation,lead,lift and all accessories etc. complete as per directions of Engineer-in -Charge.
Providing And Installing Of Metal Garden Bench of G.I With Powder Coating With Backrest Length X Height X Width 60" X 38" X 20" Powder Coated Finish including Foundation,Holding Down Bolts, Grouting Etc Complete As Directed By Engineer-In-Charge
Supply & erection of Antique Decorative arthitectural 3 meter cast iron pole, Primered and PU painted factory Finished. The column must have a hinged flush door at the bottom with proper strengthening to the cutout of the door opening. A junction/ looping box with 32 Amps heavy duty connector shall be built in to the pole and with provision of SP MCB, provided with a base plate and one set (4 Nos.) of SS J-bolts, and including 40 watts LED luminair of IP65 with die cast aluminium housing of IK 08 of reputed make of Dwarka DLR-1-30-5+VGL-U-001or equivalent subjected to approval of sample by engineer in charge and with other required accesories. Exclusive of MCB and 3c 2.5 sq mm wire from MCB to Fitting
Supply and erection of 8 Mtrs Octoganal Pappeared H.D.G.I pole made out of 4 m.m. thick plate and heavy provision for cable entry, having weight not less than 97kg. 4 Nos of J type M24x 750mm long foundation bolts of grade EN 8 as specified by GED. Along with suitable arm and LED fixture of inled make specified by GED of 80 W
Street Light Panel: Supply, Installation, testing and commissioning of LT panel IP- 67 outdoor type,floor mounted Panel, shall be suitable for 415 V, 3 phase, 4 wire, 50Hz Supply system. With 3 phase energy meter and 63A TPN MCB as incommer and 11 nos of 16 A TPN MCB as outgoing with 3 numbers of microcontoller based 25 A programmable digital Almac timer. As shown in SLD.
Laying of one number PVC insulated and PVC sheathed/XLPE power cable of 1.1 KV grade of size not exceeding 25 sq.mm direct in ground including excavation in the form of a trench as per Cable Trench Drawing provided by the Engineer-Incharge, sand cushioning with screened sand bed of 20mm thick , protective covering with bricks placed lengthwise on top of cable all over the run and backfilling the excavated earth without stones or hard material and making the surface proper with 15 cm crown on the top complete as required. In soily strata
Laying of one number PVC insulated and PVC sheathed/XLPE power cable of 1.1 KV grade of size exceeding 25 sq.mm but not exceeding 120 sq.mm direct in ground including excavation in the form of a trench as per Cable Trench Drawing provided by the Engineer-Incharge,sand cushioning with screened sand bed of 20mm thick , protective covering with bricks placed breadth-wise on top of cable all over the run( the brick protection shall cover the cable and project atleast 5 cms over the sides of the cable) and backfilling the excavated earth without stones or hard material and making the surface proper with 15 cm crown on the top complete as required. in soily strata
Earthing with GI earth pipe 2 mts long 40 mm dia medium class with ISI mark,of approved brands, including accessories and providing masonry enclosure with CI/RCC cover having locking /lifting arrangement and watering pipe etc. with charcoal or coke and salt) as required as per the Earthing Drawing provided by the Engineer-Incharge.The scope of work includes the following: a) Excavation of pit of size 1.0x1.0x 2.0 mtrs(min) and disposal of excavated soil. b) Class B GI pipe, 40mm diameter as per specifications. c) Charcoal/salt as per specs. d) Refilling the pit of size 1.0x1.0x 2.0 mtrs(min) with soft black soil of minimum resistivity i/c transportation. e)Masonary chamber with proper foundation, cover plate and locking arrangement. f) Testing of earth value with earth megger and certifications of its value. Aluminium tag with embossed earthing value to be attached to the pipe. g) watering arrangement (a) In soily strata
Providing and fixing 25 mm x 5 mm GI strip on surface or in recess for coneections etc. as required
Providing and fixing 6 SWG dia GI wire on surface or in recess for loop arthing . as required
Supply of 3 1/2 core armoured PVC/XLPE insulated, PVC sheathed aluminium conductor cable of 1.1 KV grade with ISI mark conforming to IS:1554(Part I) ,IS:7098(Part I) with latest amendments of following size. (2): 3 1/2 Core 35 sq.mm
Supply of 4 core armoured PVC insulated, PVC sheathed aluminium conductor cable of 1.1 KV grade with ISI mark conforming to IS:1554(Part I) ,IS:7098(Part II) with latest amendments of following size. (4) 4 Core 10sq.mm
Supply of 3 core unarmoured PVC/XLPE insulated, PVC sheathed copper conductor cable of 1.1 KV grade with ISI mark conforming to IS:1554(Part I) ,IS:7098(Part I) with latest amendments of following size. ' 3 Core 2.5 sq.mm
Supplying and making cable end terminations with brass compression gland and copper lugs for folowing sizes of 3 Core PVC insulated PVC sheathed /XLPE aluminium conductor cable of 1.1 KV grade, complete as required. (1) 3 x 1.5/2.5 Sq. mm.
Supplying and making cable end terminations with brass compression gland and copper lugs for folowing sizes of 4 Core PVC insulated PVC sheathed/XLPE aluminium conductor cable of 1.1 KV grade, complete as required. (4) 4 x 10 Sq. mm.
Supplying and making cable end terminations with brass compression gland and aluminium lugs for folowing sizes of 3 1/2 Core PVC insulated PVC sheathed/XLPE aluminium conductor cable of 1.1 KV grade, complete as required. (2) 3 1/2 x 35 Sq. mm.
Supplying and fixing 6 A to 32 A, C series MCB suitable for lighting and other loads of following poles in the existing MCB DB complete with connections testing and commissioning etc as required. (a) SP, Cat A
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor single core cable in the independent surface/ recessed FRLS PVC conduit of appropriate size as required. (b) 2 x 2.5 sq.mm + 1 x 2.5 sq.mm earthwire (20mm Conduit)
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor single core cable in the independent surface/ recessed FRLS PVC conduit of appropriate size as required. (c) 2 x 4 sq.mm + 1 x 4 sq.mm earthwire (20mm Conduit)
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface/ recessed PVC conduit with modular switch, modular plates, suitable size modular GI box of specified Category and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. (c) Group C -- with Cat A Modular Accessories
Wiring for group controlled light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface/ recessed PVC conduit and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.
Supplying and fixing suitable size modular GI box with modular plate and cover in front on surface or in recess including providing and fixing 3 pin 5/6 A modular socket outlet and 5/16 A modular switch connection painting etc. as required. (a) Cat A
Supplying and fixing suitable size modular GI box with modular plate and cover in front on surface or in recess including providing and fixing 6 pin 15/16 A and 5/6 A modular socket outlet modular socket outlet and 15/16 A modular switch connection painting etc. as required., a: Cat A
Supplying and fixing modular blanking plate on the existing modular plate switch box excluding modular plate etc. as required(a) Cat A
Supply and erecting of 12 inch (300 mm sweep) exhaust fan, 1400 rpm, complete with all accessories. (a) Cat A
Supplying and erecting LED surface lights of 5 to 8 W, 230V Intergral type with required driver and all the required accessories of Legro, Wipro, crompton, Bajaj, havels make or equivalet approved by Engineer - in - Charge complete as required.
Supply, Erection,Testing & Commissioning of 20 - 24 W LED TubeLight luminaire.with required Driver and other accessories of Legro, Wipro, crompton, Bajaj, havels or equivalent make approved by Engineer - in - Charge complete as required.
Supplying and fixing following way SPN sheet steel MCB distribution board 240 V on surface/ recess complete with tinned copper busbar neutral busbar earth bar dinnbar detachable gland plate interconnections phosphotized and powder painted including earthing etc. as required ( but without MCB/RCCB/Isolator)(c) 12 way single door Cat A
Supplying and fixing 6 A to 32 A, C series MCB suitable for lighting and other loads of following poles in the existing MCB DB complete with connections testing and commissioning etc as required.(e) TPN, Cat A
Supply and erecting meter box suitable for three phase energy meter and incoming SP/DP MCB, fabricated out of 16 SWG sheet steel, powder coated, complete as required and conforming to the requirements of Goa Electricity Deaprtment.
Supply, installation, testing and commissioning of electronic type three phase energy meter (KWh), 4 wire, ISI marked, in polycarbonate or sgheet steel body ( base mounting type) with counter display/LCD display, with ELT, in Class 1.0, 50 Hz, 240 V. AC duly tested by MRT along with Test Certificates, complete as required of following capacity of make L & T only.(b) 10 to 40 A
Supplying and fixing SP blanking plate in the existing MCB DB complete as required
D K BHOMKAR
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .