Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹14.1 LAccepted-AOC 72 USMAN ENCAVE SECTOR O ALIGANJ LUCKNOW 226004 UP | LUCKNOW | LUCKNOW | UTTAR PRADESH | 226004 | 1 | Accepted-AOC Due to credit and L-1 | |
| 2 | 2₹15.6 L+₹63,680 (4.26%)Rejected-Finance NAGLA UDHA NEAR PRIMARY SCHOOL POST DHANOLI AGRA UP AGRA 282010 | AGRA | AGRA | UP | 282010 | 2 | Rejected-Finance Being other than L-1 | |
| 3 | 3₹15.7 L+₹77,700 (5.20%)Rejected-Finance | 3 | Rejected-Finance Being other than L-1 | |
| 4 | 4₹15.8 L+₹89,632 (6.00%)Rejected-Finance | 4 | Rejected-Finance Being other than L-1 | |
| 5 | 5₹17.4 L+₹2.5 L (16.5%)Rejected-Finance KE 100 B KAVERI KUNJ PHASE I KAMLA NAGAR AGRA 282005 | AGRA | AGRA | UTTAR PRADESH | 282005 | 5 | Rejected-Finance Being other than L-1 |
Tender Value
₹20.8 L
EMD Value
₹41,500
Closing Date
15 Jun 2023, 6:00 pmClosed
GE (AF) Adm Area Agra 282008
GE (AF) Adm Area Agra 282008
REPAIR AND MAINT OF STREET LIGHTS PERIMETER LIGHTS HIGH MAST LIGHTS TIMER SWITCHES IN DOMESTIC AREA UNDER GE AF ADM AREA AT AF STATION AGRA
2023_MES_597017_1
8000-2048/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
AF Station Agra
Class E
cat b i
8 documents required · 8 mandatory
₹500
GE AF Adm Area Kheria Agra
₹41,500
Yes
21 Jun 2023
20 May 2023
17 Jun 2023
20 May 2023
15 Jun 2023
3 Jun 2023
20 May 2023 - 2 Jun 2023
Amount
Taking down street light fitting, flood light fittings 30/ 60/ 90/ 120/ 250 watts any type any wattage from street tubular/PCC Poles/High mast poles dismantling and checking out serviceability of part/ circuit such as drivers, MCPCB etc. replacement of unserviceable parts with new parts including soldering with existing circuit board, reassembling and refixing in position including conneting, testing complete all as specified and directed.(all UNSV accessories shall be replaced under respective items).
Supply and fixing of driver suitable for LED light fitting 15 to 30 Watt complete all as directed.
Supply and fixing of driver suitable for LED light fitting 45/60 Watt. complete all as directed.
Supply and fixing of driver suitable for LED light fitting 90/120 Watt. complete all as directed.
Material and labour for replacement of existing unsv street light fittings with LED street light fitting 45 Watts, IP 66, having pressure die cast alumnium alloy housing with heat resistant toughned glass with individual peanut LED lenses and Driver shall be IP-66 for water protection, including surge protection device 5 KV including making connections with PVC insulated and sheathed three core multi stranded aluminium conductor cable of size 1.5 Sqmm complete all as specified and directed. Make: Havells Cat Ref ENDURASUNDOWNSL45WLED 765PASY BOTG/ Philips Cat Ref BRP409 LED 040 CW HO MR FG S1 PSU GR/ Orient Cat No: LSFT-045-C
Material and labour for replacement of existing unsv street light fittings with LED street light fitting 70 Watts, IP 66, having pressure die cast aluminium alloy housing with heat resistant toughned glass with individual peanut LED lenses and Driver shall be IP-67 for water protection, including surge protection device 5 KV including making connections with PVC insulated and sheathed three core multi stranded aluminium conductor cable of size 1.5 Sqmm complete all as specified and directed. Make: Havells Cat Ref ENDURAOMNIPLUSSL 70W LED757SASY TOPC/ Philips Cat Ref BRP409 LED 070 CW HE NR PC S1 PSU GR/ Orient Cat No: LSFT-070-C
M&L for replacement of existing unsv street light fittings with LED street light fitting 90 Watts, IP 66, having pressure die cast aluminium alloy housing with heat resistant toughned glass with individual peanut LED lenses and Driver shall be IP-67 for water protection, having surge protection device 10 KV, including making connections with PVC insulated and sheathed three core multi stranded aluminium conductor cable of size 1.5 Sqmm complete all as specified and directed. Make: Havells Cat Ref ENDURAPEARLPLUS SL90WLED757 PASYTOPCAS TCC/ Philips Cat Ref BRP410 LED 091 CW HE MR PC S2 PSU GR/ Orient Cat No: LSFC-090-C-PC
M&L for replacement of UNSV GI bracket made out of GI pipe 40 mm bore medium grade bent to required shape of 0.90 mtr long and fixing to pole/wall with suitable size of nut, bolts and clamps all as specified and directed. Note :- Taking down and re-fixing of Street light if required shall be the part of this item.
M&L for replacement of existing unsv flood light fittings with LED flood light fitting 120 Watts, IP 66, having pressure die cast alumn alloy housing with heat resistant toughned glass with individual LED lenses, having surge protection device 10 KV and Driver shall be IP-67 for water protection, including making connections with PVC insulated and sheathed three core multi stranded alumn conductor cable of size 2.5 Sqmm complete all as specified and directed. Make: Havells Cat Ref JETAIRISFL120WLED757ARWBLTG/ Phillips Cat Ref BVP192 LED110 CW HO NB FG GR PSU/ Orient Cat No: LFAP-120C
M&L for replacement of existing unsv flood light fittings with LED flood light fitting 150 Watts, IP 66, having pressure die cast alumn alloy housing with heat resistant toughned glass with individual LED lenses, having surge protection device 10 KV and Driver shall be IP-67 for water protection, including making connections with PVC insulated and sheathed three core multi stranded alumn conductor cable of size 2.5 Sqmm complete all as specified and directed. Make: Havells Cat Ref JETAIRISFL150WLED757ARNBLTG/ Phillips Cat Ref BVP122 LED150 CW HE NB FG XTFCL S4/ Orient Cat No: LFAP-150C
M&L for replacement of existing unsv flood light fittings with LED flood light fitting 250 Watts, IP 66, having pressure die cast alumn alloy housing with heat resistant toughned glass with individual LED lenses, having surge protection device 10 KV and Driver shall be IP-67 for water protection, including making connections with PVC insulated and sheathed three core multi stranded alumn conductor cable of size 2.5 Sqmm complete all as specified and directed. Make: Havells Cat Ref JETAIRISFL250WLED757ARNBLTG/ Phillips Cat Ref BVP122 LED250 CW HE NB FG XTFCL S4/ Orient Cat No: LFAP-250C
Excavating in trenches n.exc 1.5m wide and n.exc 1.5m in depth for foundation etc or for laying for cables etc n.exc 10 sqm on plan and n.exc 1.5m in depth and getting out in any type of soil including removal of sand, bricks/PCC covers laid for cable proection complete all as specified and directed.
Returning, filling in, trenches including spreading, levelling, watering and well ramming in layers not exc. 25 cm in any type of soil complete all as specified and directed.
Removing surplus excavated material n.exc 50 m and depositing where directed at a level n.exc 1.5 m above the starting point complete all as specified and directed.
Supply & laying in replacement of brick, double walled corrugated (DWC) HDPE duct pipe in 6 m lenght conforming to IS 16205 Pt-24 of approved colour complete with fittings for cable protection of size 50 mm inner dia and 63 mm outer dia complete all as directed.
S&L in replacement XLPE LT UG cable PVC insulated, bedded armoured heavy duty electric cable 1100 volts grade with aluminum conductor of 25 Sq mm 3.5 core laid in trenches or fixed on wall/floor/poles complete all as specified and directed.
Supply and fixing in replacment nature switch complete with timer, contactor, relays and suitable rating MCBs for incoming and out going in built in suitable IP 66 enclosure (Hensel) of three phase integrated models of capacity 8 KW complete all as specified and directed.
All as per item No. 17 above but of single phase integrated models of capacity 8 KW
Supply and fixing thermoplastic polystyrene /polycarbonate enclosure bus bar chamber, shock proof, vermin proof and dust proof complete with 04 Nos aluminium strip of capacity 100 Amps including non metalic clamps and GI nut bolts and washers of suitable size and fixed on pole / wall complete all as specified and directed.
S&F in replacement Weather proof thermo (Polysterene) cable junction box, having protection class IP-66 and overall minimum size 155 x 210 x 92 mm having metric knockouts on the wall, dully fixed on the pole with aluminium strip 25 x 3 mm clamp, GI bolts, nuts, washers and 2 Nos. polymide weather proof cable glands of cable sealing range 10 mm to 17 mm (complete with check nut) and including 1 No 30 Amps with cable connector and 1 No. 0.50 Amps MCB SP complete all as specified and directed. Make :- Hensel Cat Part No. DK 1616 G or equivalent in ABB/ Seimens
S&F in replacement timer switch, 16 A, 240 Volts, single phase complete all as specified and directed. Make:- Havells cat part No. DHTMNX5016 or equivalent in Siemens/L&T/ Legrand
M&L for locating and repairing street light feeder fault (OH lines or UG cables) such as short circuiting, snapping of conductors, phase/ neutral loss in UG cables etc. and making the defective circuit serviceable in all respects complete all as directed. Note:- (a) Repairing of fault in one circuit, irrespective of any number of street lights/ poles/ junction boxes etc at any location shall be treated as one job. (b) Earth work, if required shall be measured and paid separately under respective item. (c) All type of T&P, PVC insulation tape, minor nuts/bolts/washers/ thimble/lugs etc. required shall be provided by the contractor without any extra cost to the Govt. (d) Any loose/ broken overhead conductor shall be restringed/ repaired to make the system functional in all respects and unit rate quoted shall deemed to include the cost of the same.
M&L for disconnecting of burnt/damaged cables from panels/ junction boxes etc. cutting out the burnt out ends, making new end joints by supply and fixing new aluminium lugs/ insulation tapes etc. and reconnecting using new nuts/bolts/washers/ thimble/lugs etc. and restoring three phase and neutral connection in the junction box for 10/16/25 Sqmm 2/3.5/4 core size LT underground cable complete all as specified and directed. Note:- Earth work required for extending the incoming/outgoing cable in junction box/ panel etc. shall deemed to be included in unit rates.
M&L for electric / gas welding in panel / pole/ any other work complete all as specified and directed.
S&L/ fixing in replacement of unsv 1100 volts grade, 4 core 2.5 Sqmm PVC insulated and PVC round sheathed multicore bright annealed bare copper conductor cable including suitable size of copper lugs as per IS:694/1990 complete all as specified and directed .
Dsmantling of existing light and Supply and fixing of Lithium based Energy Efficient integrated Solar street light of 40 Watt in single FRP body with duly polylurethane coating, encases with Monocrystalline solar PV Panel of 64/66 Wp, litium battery 11.1/12.8 V, 36.0 AH with inbuilt BMS, IP65 high brightness W LED 160-180Lm/watt) lamp with Aluminium reflector, CRI>70, Colour Tempeture 5700K-6500K micro controller based charge controller cum driver automatic dimming function(First four hours at full brightness & rest at lower light level with PIR motion sensor), dust to dawn operation suitable to working tempreture -100 C to +550 C, weight more than 6-18 Kg with suitable size of GI bend pipe, adjustable MS clamp suitable for pole/wall mounting etc complete all as specified and directed. Make - Cat part no.- Axxon -AXN-40 watt of Xxxon Tech Industries./ Orient /Okaya Power Pvt Ltd / Havells
S&L/ fixing in replacement of unsv 1100 volts grade heavy duty PVC insulated aluminium conductor, bedded unarmoured cable of size 10 Sqmm 2 core fixed on wall/floor/poles complete all as specified and directed .
MUKTA AND COMPANY
M/s Pooran Singh and Company
Balaji Associate
M/s Sumer Associates
GUPTA ENGINEERING WORKS
CHAHAR CONTRACTOR AND SUPPLIERS
Industrial Traders
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .