Loading…
Loading…
| # | Company | Quoted % | Amount | Rank | Status |
|---|---|---|---|---|---|
| 1 | L1₹2.3 LAdmitted-Finance 16 1 NEW SANTOSH PUR MAIN RD CAL 75 700075 | KOLKATA | KOLKATA | WEST BENGAL | 700075 | +0.00% | ₹2.3 L | L1 | Admitted-Finance |
| 2 | L2₹2.3 L+₹3,438.43 (1.51%)Admitted-Finance | +1.51% | ₹2.3 L+₹3,438.43 (1.51%) | L2 | Admitted-Finance |
| 3 | L3₹2.4 L+₹9,768.78 (4.29%)Admitted-Finance 889 RAJA RAMMOHAN ROY ROAD KOLKATA 700041 | KOLKATA | WEST BENGAL | 700041 | +4.29% | ₹2.4 L+₹9,768.78 (4.29%) | L3 | Admitted-Finance |
Tender Value
₹2.3 L
EMD Value
₹5,000
Closing Date
17 Aug 2026, 2:00 pmClosed
The Executive Engineer ( E )
Kolkata Municipal Corporation Santoshpur Market Complex, 1st Floor Kolkata-700 075
REPAIRING OF LIGHTING SYSTEM AT EAST RAJAPUR SANTOSHPUR RASHMONI BAGAN ETC. AREAS IN WARD NO-103, BR-XI
2026_KMC_1036621_1
KMC/LTG/Z-IV/93/26-27/PD
Open Tender
ELECTRICAL WORKS M/R
Percentage
30 days
WARD NO.103, BR-XI
Please refer Tender documents.
4 documents required · 4 mandatory
₹0
₹5,000
7 Sept 2026
7 Aug 2026
17 Aug 2026
7 Aug 2026
17 Aug 2026
7 Aug 2026
This is a percentage-rate BOQ. The schedule below shows estimated quantities and rates. Bidders quote a single percentage above or below the total estimated cost.
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | SCHEDULE OF RATES FOR OVERHEAD LINE INSTALLATION - REPAIR 14. Dismantling steel tubular/Rail/Strut embedded in CC foundation incl. excavation, filling of holes, restoring surface,loading at site and delivering, unloading, sorting, stacking properly at any place as per direction upto a lead of 1.6 km | - | PPL | 649 | - |
| 2 | SCHEDULE OF RATES FOR OH LINE INSTALLATION (LT DISTRIBUTION).Erection of Poles.Erection of Single Steel tubular pole of length as given below with/without sole plate & Cap etc. in CC foundation (Proportion and dimension indicated below), having 600x600x150 mm thick CC (4:2:1) base block below sole plate/pole with hard jhama metal including CC (6:3:1) muffing 0.30 mts. dia and 0.30 mts. above ground level including 3 mm thick neat cemented finish and GI earth bolt after making drilled holes etc. on pole & carriage of pole upto 1.6 Km from Store to work(site including filling up the excavated earth pit with shifted soil and ramming properlyUpto 9.0 mtr. Size 0.6x0.6x1.70 mts | - | SET | 2,835 | - |
| 3 | SCHEDULE OF RATES FOR EARTHING INSTALLATIONS.Earthing Installation ... with Pipe Electrode.Earthing with 50 mm dia GI pipe 3.64 mm thick x 3.04 Mts. long and 1 x 4 SWG GI (HOT Dip) wire (4 Mts. long), 13 mm dia x 80 mm long GI bolts, double nuts, double washers incl. S & F 15 mm dia GI pipe protection (1 Mts. long) to be filled with bitumen partly under the ground level and partly above ground level driven to an average depth of 3.65 Mts. below the ground level as below:(a)By ISI Medium GI pipe. | - | SET | 1,369 | - |
| 4 | Supplying Al.conductor PVC insulated and sheathed unarmoredcable (1.1KVgrade, Gloster/Havells/Polycab). 10sqmm x 2core | - | RGM | 64 | - |
| 5 | SCHEDULE OF RATES FOR OVERHEAD LINE INSTALLATION - REPAIR 13. Providing CC (6:3:1) muffing 450x450x600 mm in size or equivalent size of cylindrical muffing above ground level around the pole base complete with 3 mm thick neatly finished cement plaster all round after dismantling the unserviceable muffing if any incl. fixing only loop box if necessary (a) Without Loop Box | - | EA | 629 | - |
| 6 | Supplying Al.conductor PVC insulated and sheathed unarmoredcable (1.1KVgrade,Gloster/Havells/Polycab). 4sqmm x 2core | - | RGM | 48 | - |
| 7 | Supply and drawing of 7/14 SWG galvanised stranded wire for drawing unarmored cable (supply of cable is not included in the scope) by catenary system of wiring with 3nos. reel insulator per mtr. and binding with binding wires etc,as reqd. for drawing | - | RGM | 28 | - |
| 8 | Drawing of unarmoured cable of suitable size (supply of cable is not included in the scope)on existing Galvanized stranded wire for centenary system with reel insulators and binding wires. | - | RGM | 7 | - |
| 9 | S/F arm bracket of 50 mm bore tubular Pipe (M.S.) of 1. 5 m (5') length for fixing on 75/100 mm pole top including S/F 4 mm thick M.S. plate welded with bolts, nuts & clamps, etc. as required with fabrication work | - | EA | 1,058 | - |
| 10 | Supplying of 1.1 KV. Grade PVC insulated Conductor of following cables (make: Polycab/ Gloster/Havells/):Size in Sq. mm, No & dia. of wire in mm , No of Core - 16 7/1.70 4 | - | RGM | 151 | - |
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.17 MB
BOQ_2546436.xls
BOQ • 0.26 MB
form.pdf
Tender Documents • 0.94 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .