| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹25.8 LAccepted-AOC SURVEY NO 93 392 PACHMARHI NEAR MILITARY HOSPITAL PAHMARHI HOSHANGABAD M P 461 881 | PACHMARHI | HOSHANGABAD | MADHYA PRADESH | 461881 | L1 | Accepted-AOC Lowest bidder | |
| 2 | L2₹27.7 L+₹98,920 (3.70%)Rejected-Finance 270 ADARSH NAGAR ROORKEE HARIDWAR 247667 | HARIDWAR | UTTARAKHAND | 247667 | L2 | Rejected-Finance Other than lowest bidder | |
| 3 | L3₹29.0 L+₹2.3 L (8.41%)Rejected-Finance | L3 | Rejected-Finance Other than lowest bidder |
Tender Value
₹30 L
EMD Value
₹60,000
Closing Date
19 Oct 2024, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE(S) Jaipur
Garrison Engineer (South) Jaipur Military Engineer Services Kalyan Marg, Jaipur302006
REPAIR AND MAINT OF COOLING APPLIANCES AND WINTER APPLIANCES AT ZONE III HOLIDAY HOME, MES IB, ECHS, CIU, CWE OFFICE, GE SOUTH, GE CTL, EM INSTALLATIONS AND GE PROJECT UNDER GE(S) JAIPUR
2024_MES_673251_1
GE(S)/J-32P/2024-25 8887/E8
Open Tender
Civil Works
Item Rate
330 days
GE(S) Jaipur
Class D and category b(i)
9 documents required · 9 mandatory
₹500
GE(S) Jaipur
₹60,000
Yes
4 Jan 2025
9 Sept 2024
26 Oct 2024
9 Sept 2024
19 Oct 2024
3 Oct 2024
Amount
Dismantling / taking down unservisable air conditioner 1.5TR / 2TR capacity window type from any place and install the AC at location after repair and testing complete all as directed. Note : Repair work and replacement of damaged parts shall be measured and paid seperately.
All as per Item No. 01 above, but AC 1.5/2 TR split type.
M&L for servicing of 2TR/1.5TR capacity window type AC unit by cleaning with air pressure,tighting of bolts and nuts, arresting all leakages with necessary brazing/welding ensuring leak proof cleaning of condensor ,water line, checking of serviceability of fan ,motor ,compressor,relay ,capacitors thermostat,control circuit remote,sensor indicator electric circuits,replacing of unserviceable parts except compressor and charging of refrigerant gas and submit the report complete all as specified and as directed by Engr-in-charge. Note : (i) Replacement of compressor shall be measured and paid separately. (ii) Spare Parts required for replacement shall be measured and paid separately under respective items given here-in-after. (iii) Gas will be measured and paid separately.
All as per item No 03 here in before but for AC 2TR/1.5TR capacity split type
M&L for disconnecting and removing unserviceable sealed compressor unit from 1.5 TR capacity window type AC including supply connecting with original/ existing make sealed refrigeration compressor unit all as specified and as directed by Engr-in-charge.
All as per item No 05 above, but for AC 2 TR capacity window type.
All as per item No 05 here in before but for AC 1.5TR capacity split type.
All as per item No 05 here in before but for AC 2 TR capacity split type.
Supply only Running capacitor 45 to 50 MFD 230 volts, 50 Hz for window/split AC.
Supply only Starting capacitor 100 to 120 MFD 230 volts, 50 Hz for window/split AC.
Supply only Box type relay suitable for Window type AC 1.5 ton capacity.
Supply only Thermostatic switch with knob suitable for window type AC 1.5 TR.
Supply only Capacitor 4 MFD, 230 volts, 50 Hz.
Supply only Blower Motor, single phase 230 Volts 1500 RPM, suitable for 1.5 TR Window type Air Conditioner.
Supply only Blower Motor, single phase 230 Volts 1500 RPM, suitable for 2.0 TR Window type Air Conditioner.
Supply only Blower Motor, single phase 230 Volts 1500 RPM, suitable for 1.5 TR Split type Air Conditioner.
Supply only Blower Motor, single phase 230 Volts 1500 RPM, suitable for 2 TR Split type Air Conditioner.
Supply only Scroll complete with bush sauitable for window/ split type AC as per sample.
Supply only front grill suitable for 1.5/2 ton window type AC.
Supply only Plastic filter for window type AC 1.5 ton capacity.
Supply only Over load protector suitable air conditioner 1.5 ton capacity.
Supply only gas Mafron-22 in sealed cylinders. Note : Cylinders shall be return after use.
Supply only gas R-134 A in sealed cylinder. Note : Cylinders shall be return after use.
Labor only for Gas Charging for AC 1.5/2 Ton and testing complete. Note : Gas will be measured and paid separately.
Rewinding of electric motor blower fan motor of 1.5/2.0 ton window/ split type AC 1400 RPM 220 V 50 C/S with supper enameled copper wire of suitable size including, replacement of shaft, bushes, capacitor and testing on load all as directed.
Supply only remote control complete for split type ACs 1.5 to 2 ton capacity
S&F of U/S single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole 25 Amps MCB, 240 volt complete all as spacified and directed.
Supply only PCB coil suitable for 1.5/ 2 ton split type AC.
Supply only contactor suitable for Split type AC capacity 1.5/2.0 ton.
Supply only fan blade suitable for out door unit of Split type AC capacity 1.5/2.0 ton.
Supply only blower complete with fins suitable for in door unit of Split type AC capacity 1.5/2.0 ton.
Disconnecting electrical connection and dismantling/ taking out indoor and out door unit of split type air conditioning of any make and capacity from any place and installation, commissioning and testing to another location including transportation from existing bldg to another bldg all as spacified and directed.
Dismantling/taking out of water cooler for repair such as repair/replacement of compressor. fan motor. tank repair etc from any place, and any capacity, transported to workshop & back after repair complete all as specified and directed. Note : Repair work and replacement of damaged parts, shall be measured & paid seperately under respective.
Supply & fixing Compressor (Sealed Unit ) suitable for 40/80 Litre Water Cooler.
Labour only for Gas Charging of Water Cooler complete . Note : Gas will be measured and paid separately.
Supply & replacement of copper tubing including cutting brazing, flaring and testing of size 1x4”x22SWG in required length including insulating piping complete all as specified and directed
M & L for welding 4 nos MS Angle 50 x 50 x 6mm of 15 cm long as leg of water cooler complete all as specified and directed
M&L in repair for stopping tank leakage with Brass nipple (set of the three ) 10 mm dia n. exc. 4 cm. long with copper/brass washer nut bolts complete with necessary welding, threading, making hole and to make leak proof & teasting complete all as specified and directed
M & L for repairing of body of Water Cooler by welding of MS sheet of the patch of 680x175x1.00mm thick, rubbing, scrapping, making good welded portion,painting with one coat of red oxide primer and two coat of synthetic enamel paint complete all as specified and directed
Supply and fixing in repair of Fan Motor 1/10 H.P Single phase,230V for water cooler.
Supply and fixing in repair Fan Motor blade as per sample all as directed.
Supply & fixing Thermostate for water cooler complete.
Supply & fixing 20mm bore Push type C.P. cock for water cooler.
Supply & fixing 20mm bore float valve brass for water coolers / desert cooler as per sample.
Supply & fixing 20mm bore float valve PVC for water coolers as per sample.
Supply & fixing of water drain-out tray stainless-Steel thicknees 0.71 mm for water cooler any make /size , with PVC waste pipe ,pipe clamp, complete all as specified and directed.
Supply & fixing Starting capacitor 60 to 80 MFD 230 volts, 50 Hz.
Supply & fixing over load relay suitable for Water cooler 40 t0 60 litre.
Labour only for Gas Charging of Refrigerator including necessary testing complete. Note : Gas will be measured and paid separately.
Supply and fixing in repair of compressor (sealed unit) with relay suitable for refrigerator of capacity 300 / 280 Litre all as specified and as directed by Engineer-in-Charge.
All as per item No. 51 above, but for capacity of 165/175 Litre capacity.
Supply and replacement of Thermostatic switch with knob suitable for Refrigerator.
Supply and replacement of over load protector relay suitable refrigerator any capacity.
Supply and replacement of box type relay suitable for refrigerator 165 to 310 Litre capacity.
Supply and replacement of evaporator coil assembly for refrigerator 165 to 310 Litre capacity.
Supply and replacement of Magnetic door gasket for refrigerator 165 to 310 Litre capacity.
Supply and replacement of Vegetable tray for refrigerator 165 to 310 Litre capacity.
M&L for repairs / servicing of desert cooler 4000 cum/hrs air flow capacity single phase 230 Volts of various make after disconnecting incoming and outgoing electric/water connection drain out water and carry out minor repair work such as repairing of internal worn out wires, motor ,Pump, Fan vicket, Lead wire , switch regulator , PVC Pipe Name plate , and replacement of unserviceable parts including testing after servicing complete all as specified and directed by Engr-in-charge. Note : Spares parts required for replacement shall be measured and paid separately as supply only in respective items.
Supply only wooden shelving pad for Desert cooler each set weight not less than 500 grams of size 75 cm x 60 cm all as directed.
Supply only wooden shelving pad for Desert cooler each set weight not less than 800 grams of size 150 cm x 100 cm all as directed.
Supply only Fan Blade PVC/iron body with nut Bolt washer for 4000 cum/Hr Desert Cooler of various makes all as per existing one all as specified and directed by Engr-in-charge.
Supply only side panels made of MS Sheet 2 mm thick for 4000 cum / hr Desert Cooler
Supply only Fan motor for Desert cooler of various makes all as per existing one all as directed.
Supply only Submerssible pump with suitable head for Desert coolers complete all as specified and directed.
Supply only Switch Piano 5 Amp single pole 230 volt.
Supply only Fan regulator for 4000 cum/Hr Desert Cooler capacity of various makes all as per existing one all as specified and directed.
Supply only Name Plate for 4000 cum/Hr Desert Cooler capacity of various size and various makes all as per existing one all as specified and directed.
Supply only PVC Lead wire 1.5 sqmm stranded copper conductor 1.5 sqmm3 core ISI Marked all as specified and directed.
Supply only PVC flexible pipe (from vertical pump to distributer and distributer to panel) 15mm dia for Desert cooler including 3 way distributor junction tee set complete all as specified and directed.
Supply only Flexible Core PVC insulated with stranded copper conductor 70 / 0.0076 Sqmm 3 core 600/1100 V ISI Marked all as directed.
Supply only PVC pipe connection, both end screwed 18” long 15mm dia with brass nuts and neoprene washers for water cooler/ desert coolers complete all as specified and directed.
S&F Plug top for desert cooler 3 pin 5 Amps, 230 Volt AC, ISI marked complete all as specified and directed.
M&L for painting of Desert cooler with two coats of synthetic enamel paint after surface preparation including paint of alphabets 5 cm hight,5 cm thick not more than 50 Alphabets complete all as specified and directed.
M & L for Repairs of Voltage stabilizer of 1 KVA to 5 KVA capacity single phase 230 Volts of various make after disconnecting incoming and outgoing electric connection and carry out minor repair work such as repairing of internal worn out wires, repair to electronic circuit plate, low/high cutoff circuit and replacement of unserviceable parts including reconnecting after repair and testing by connecting on load and adjusting low/high cutoff and timing relay all as directed. Note : Spares required for replacement shall be measured and paid separately as supply only in respective items.
Supply only Electronic circuit plate (P C B) with timer suitable for 4 KVA/5 KVA stabilizer.
Supply only Electronic circuit plate (P C B) with timer suitable for 1 KVA/2 KVA stabilizer.
Supply only Circuit plate (P C B) for high and low cut off suitable for 4 KVA/5 KVA stabilizer.
Supply only Circuit plate (P C B) for high and low cut off suitable for 1 KVA/2 KVA stabilizer.
Supply only Instant start switch.
Supply only Trigger Transformer 500 MA to 750 MA suitable for 4 KVA/5 KVA voltage stabilizer.
Supply only Trigger Transformer 500 MA to 750 MA suitable for 1 KVA/ 2 KVA voltage stabilizer.
Supply only Relay 5 Amps 230 volts suitable for 1 KVA/ 2 KVA voltage stabilizer.
Supply only Indicator lamp complete for AC 230 Volts Red or Green round shape as per requirement)
Supply only Voltmeter 0-300 volt round/square type.
Supply only cut out 16 Amps porcelain type 230 Volt SP
Rewinding of Main transformer with super enameled copper wire of suitable size including varnishing and heating complete for 1 KVA/ 2 KVA voltage stabilizer.
Rewinding of Main transformer with super enameled copper wire of suitable size including varnishing and heating complete for 4 KVA/ 5 KVA voltage stabilizer.
Supply only Relay 30 Amps capacity suitable for 4 KVA/ 5 KVA voltage stabilizer.
Taking down carefully existing storage type Geyser 25/50 litres capacity for repair complete overhauling including cleaning of geyser assembly inlet outlet pipe etc and re-fixing in position all as directed by Engineer-in-Charge. Note :- Any item required in replacement shall be measured and paid for separately
Cleaning and preparation of outer surface of Geysers 25/50 litres capacity and painting with two coats of white synthetic enamel paint as directed by Engineer-in-Charge.
M&L for opening of geyser in position for carry out minor repair such as loose connection testing of thermostat, heating element, tightening of screws, PVC connection etc all as directed Note :- Any item required in replacement shall be measured and paid for separately as under :-
Supply only Stainless steel inner tank of capacity 25 litre.
Supply only Stainless steel inner tank of capacity 50 litre.
Supply only Glass wool/ rock wool for thermal insulation.
Supply only Outer tank made of MS sheet powder coated suitable for 50 Ltrs.
Supply only Outer tank made of MS Sheet powder coated suitable for 25 Ltrs.
Dismantling of bottom assemble and de-scaling with acid and wire mess brush cleaning and refixing the same.
Supply only PVC insulated and over all PVC sheathed copper conductor wire of size 2.5 Sqmm x 3 core, Lead wire.
Supply only Plug top 3 pin, 15 Amp.
Supply only heating element of capacity 1.5 KW.
Supply only heating element of capacity 2.0 KW.
Supply only heating element of capacity 1.5 KW having 115mm dia base with 6 hole with diaphram washer suitable for geyser 25 litre capacity.
M&L for replacement of Geyser bottom assembly of 7 hole/9 Hole/6 hole as per existing complete including, bolts and rubber gasket for 25/50 litres capacity Geysers as per requirement with the same make which is to be replaced.
M&L for Pressure release safety valve for Geysers spring loaded suitable for 15mm pipe chromium plated.
M&L for replacement of thermostat ISI marked of any make/ capacity of geyser.
M&L for replacement of neon indicator lamp round or rectangular type.
M&L for replacement of PVC flexible connection hot and cold, high strength, impeccable finish, corrosion resistance 450mm long for geyser
M&L for replacement of PVC flexible connection hot and cold, high strength, impeccable finish, corrosion resistance 600mm long for geyser
S&F in repair tubes 15mm bore medium grade galvanized with all fittings and fixed complete to walls and ceiling or laid in floors.
S&F in repair Angle stop valve of PTMT any colour high pressure screwed for iron pipe (Minimum weight 15mm-90gms) all as spacified and directed.
S&Fix in repair Bib taps , cast copper alloy with crutch of butter fly handle screwed down , screwed for iron pipe or for brass ferrule, fancy type and fixed of size 15 mm dia complete all as spacified and directed.
Disconnecting electrical connection and water connection and dismantling/ taking out Geyser of any make and capacity from any place and installation, commissioning and testing to another location including grounting nut and bolts with washers or with fasteners and testing complete all as specified and directed by Engineer-in Charge.
M&L Point wiring using approved colour coding as per IS, with stranded copper conductor 2.5 Sq. mm (nominal area), single core, FRLS insulated, PVC insulated and unsheathed stranded cable 1100 volts grade, confirming to IS-694/ISI marked in and including PVC casing caping 25mm wide medium grade, ISI marked, with mild steel sunken boxes with earth dolly zink coated and including mounting frame and over cover plate, including PVC insulated stranded copper conductor 2.5 Sqmm (nominal area) single core FRLS cable 1100 V grade as continuous earth wire to earth dolly for 3 pin switch socket outlet15Amp independent board complete all as specified and directed by Engineer in charge including taking out old with switch and sockets.
S&F Switch Piano type type 230/ 250V grade on top covers 16 Amp.
S&F Socket outlet multipurpose use, 230/250 Volts grade 2-in-1 3 pin 6 & 16 Amp Flush Type.
Descaling of solar collectors with acid (dilute)for solar water heater panel of 200 LPD as recommended by manufacturer including cleaning and re-assembling complete and soldering for change complete all as specified and directed.
Descaling of solar collectors with acid (dilute) for solar water heater panel of 100 LPD as recommended by manufacturer including cleaning and re-assembling complete and soldering for change complete all as specified and directed.
Takinng down water inlet/outlet of solar collectors plate , disconnetion of mounting and dismantlling into parts and cutting inner copper tubes, removing the scaling from the chocked copper tube by drilling and scraping with hard metal rods including washing with acid(dilute) for solar panel 3 Nos suitable for 200 LPD having 6 Nos tubes in each panel, brazing with existig pipes after descaling complete including testing for leackage, if any and reassembling the same in the existing mounting after cleaning and solldering for change complete as per maufacturer instruction and as directed.
Takinng down water inlet/outlet of solar collectors plate , disconnetion of mounting and dismantlling into parts and cutting inner copper tubes, removing the scaling from the chocked copper tube by drilling and scraping with hard metal rods including washing with acid(dilute) for solar panel 1 Nos suitable for 100 LPD having 6 Nos tubes, brazing with existig pipes after descaling complete including testing for leackage, if any and reassembling the same in the existing mounting after cleaning and solldering for change complete as per maufacturer instruction and as directed.
Supply and replace hose pipe for hot and cold water as per existing
Taking out U/S gate valve and supply and fixing of Gun Metal gate valve 15mm dia ISI marked.
Taking out U/S gate valve and supply and fixing of Gun Metal gate valve 20mm dia ISI marked.
Supply & replace following U/S item from sheet metal enclosure complete 240 Volts, AC supply.
Metallic Plug top.
Metallic socket
MCB 5 to 32 Amp, 10 KA, SP "C' Series
S&F single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole 20 amp MCB 240v c series.
S&F in repalacement of rusted Angle iron of size 40x40x5 mm for supporting Solar panels on roof top including welding and fixing with suitable nut bolts and washer complete all as specified and diercted.
M&L for PCC (1:2:4) type B-1 in cement concrete for grouting agles in roof surface with using 20 mm graded stone complete all as specified and directed.
A.S. CONSTRUCTION COMPANY (BID ID -3136698)
SHREE BHAGWATI ENTERPRISES (BID ID -3144425)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .