| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹19.8 LAccepted-Finance | L1 | Accepted-Finance Tender accepted by competent authority | |
| 2 | L2₹20.1 L+₹29,765 (1.50%)Accepted-Finance | L2 | Accepted-Finance Lowest tender of M/s Vishal contract Works, Nagpur is accepted | |
| 3 | L3₹20.7 L+₹92,400 (4.67%)Accepted-Finance | L3 | Accepted-Finance Lowest tender of M/s Vishal contract Works, Nagpur is accepted |
Tender Value
₹16.6 L
EMD Value
₹33,241
Closing Date
17 Jul 2023, 6:00 pmClosed
Eecutive Engineer (E), Mumbai
O/o Executive Engineer(E ), 5 th Floor A Wing, BSNL Admin Building, santacruz(W), Mumbai 54
Providing EI and Fans and Electrical items at BSNL Admin Bldg, Santacruz in connection with relocation of various offices on account of office renting space to GST Department.
2023_BSNL_160364_1
16/EEE/BSNL/ED/MI/2023-24
Open Tender
Electrical Works
Item Rate
90 days
Santacruz (W), Mumbai
Please refer Tender Documents
2 documents required · 2 mandatory
₹590
Yes
AO (F and A ) BSNL
₹33,241
2 Aug 2023
7 Jul 2023
21 Jul 2023
7 Jul 2023
17 Jul 2023
7 Jul 2023
Amount
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required
a) Group -C
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required
a) 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire
b) 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
c) 4X 2.5 sq. mm + 2 X 2.5 sq. mm earth wire
d) 2x10 sqmm + 1x6 sqmm Earth wire
e) 4x16 sq mm + 2 x6 sqmm Earth wire
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 amps modular socket outlet and 5/6 amps modular switch, connection etc. as required
Supplying and fixing suitable size GI box with modular plate and cover in FRLS on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 amps modular socket outlet and 15/16 amps modular switch, connection etc. as required
Installation, testing and commissioning of pre-wired, fluorescent fitting / compact fluorescent fitting of all types, complete with all accessories and tube etc. directly on ceiling/ wall, including connection with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required.
Installation, testing and commissioning of pre-wired, fluorescent fitting / compact fluorescent fitting of all types, complete with all accessories and tube etc., including supplying and fixing ball and socket arrangement, 2 no. down rods of 20 mm dia X 1.6 mm thick steel conduit upto 30 cm length, painting and wiring the down rods and connection with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required
Providing and fixing extra conduit down rod of 20 mm dia, 2 X 10 cm length wiring with 2 X 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable including painting etc. as required. (Note : More than 5 cm length shall be rounded to the nearest 10 cm and 5 cm or less shall be ignored)
Installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable etc. as required
Installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required. (Upto 450 mm sweep)
Supplying and drawing of UTP 4 pair CAT 6 LAN Cable in the existing surface/ recessed steel/ PVC conduit as required. 4 pair UTP CAT 6
a) 1 run of Cable
b) 2 run of Cable
Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.
Supplying and fixing following Modular switch/socket on the existing modular plate &switch box including connections but excluding modular plate etc as req.
a) 5/6 A Switch
b) 3 Pin 5/6A Socket outlet
Supplying and fixing following size /modules GI box along with Modular base & cover plate for modular switches in recess etc as required.
a) 8 Module
b) 12 Module
Supplying and fixing Modular blanking plate on the existing switch box excluding modular plate as required
S/F DP steel enclosure on surface /Recess along with 25/32A ,240 V, C curve DP MCB complete with connection, testing and commissioning etc as reqd
Supplying and fixing call bell/ suitable for single phase 230V complete as required.
Supplying and fixing following size of medium class PVC conduit along with accessories in Surface /Recess i/c cutting the wall and making good the same in case of recessed conduit.
Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)
a ) 4 Way (4+12) , Double Door
Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, 10 kA, “C” curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
a) Single Pole
Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required a) 63 A
S/F Energy efficient decorative ultra slim square profile LED lighting fixture having 18 Watt 2100 Lumens, IP -20, PF -0.9, suitable for voltage range of 160-240 Volt, with extruded polycarbonate, environmental friendly including giving connection , testing etc as required [M/s Philips model No- BN 021 LED 125-6500 PSU GR(4feet) or similar Superior make with similar specification ]
SITC of recess mounting type 30W, LED luminaire, 595 mm x 595 mm, modular fitting in metal casing and suspension arrangement with suitable size MS chain links (from ceiling / tray), wiring connections, including providing 20 mm dia. MS Flexible pipe alongwith sockets at both ends complete as required. [Make and model equivalent to M/s Philips RC380B LED36S-6500 G6 L60W60 PSU OD / or similar superior make with same specification ]
Supplying and fixing 400 mm white shade Pedestal fan with 3 Nos aluminium blade, motor speed 2000 RPM , 3 Nos speed setting suitable for indoor use etc complete as req.( M/s Bajaj media BD07 or SS make)
Removing of exiting 1.5TR Split AC units consisting of Indoor & Outdoor units, Refrigerant piping, Control cable, MS Stand and with necessary pump down of refrigerant in existing outdoor unit etc from various chambers of GM /DGM s in Admin Bldg and shifting to the new location in Admin Bldg including necessary loading , unloading etc complete as as reqd.
Supplying and Fixing of Angle iron stand i/s cutting, welding and two coats of primer and two coats of approved enamel paint for fixing of outdoor AC unit etc complete as required.
Installation, Testing & commissioning of wall mounted 1.5 TR Split AC unit at new location i/c installation of Condenser unit on existing M.S. stand, indoor unit , providing nut bolts, I/c vaccumizing the system, leakage test , testing of indoor and outdoor unit etc complete as reqd
Supply & Fixing following size copper refrigerant pipes if required at site I/c cutting, bending, brazing etc. complete as reqd
a) 1/4" Dia Copper Refrigerant pipe
b) 5/8" Dia Copper Refrigerant pipe
c) Polythene foam insulation
Complete gas charging with R22 gas for existing AC unit after attending gas leakage i/c pressure testing & vacumizing as reqd
Supplying and fixing modular type RJ-45 LAN socket etc as req
Earthing with GI earth plate 600mmx600mmx6mm thick including accessories and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2,7 metre long etc with charcoal/coke and salt as required.
Providing & Fixing 25mmx5mm GI strip in 40 mm dia GI pipe from earth electrode including connection with GI nut , bolt,spring washer , excavation and refilling etc as required.
Providing & Fixing 25mm x 5mm GI strip on surface or in recess for connections etc as req.
Supplying and fixing following way, Single Pole & and neutral, sheet steel, MCB distribution board, 240 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)
12 Way - Double Door
Supplying and fixing following rating, double pole(single phase & Neutral), 240 V,residual current circuit breaker (RCCB) , having a sensitivity current 30 Ma in the existing MCB DB complete with connections, testing and commissioning etc as req. a) 25 A
Supplying and fixing 400 mm wall mounting fan with 3 Nos aluminium blade, motor speed 1300 RPM , 3 Nos speed setting suitable for indoor use etc complete as req. [ Bajaj Midea BW 07 or Similar Superior Make]
M/s THAKUR AND COMPANY NAGPUR
vaibhav enterprises
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .