| 1 | L1₹34.7 LAccepted-AOC 1814 NARSING NAGAR RANJHI JABALPUR MP 482005 | JABALPUR | JABALPUR | MADHYA PRADESH | 482005 | L1 | Accepted-AOC L1 bidder lowest | |
| 2 | L2₹34.8 L+₹12,785.86 (0.37%)Rejected-Finance BLOCK NO 403 BENGALI COLONY RANJHI JABALPUR | JABALPUR | JABALPUR | MADHYA PRADESH | 482005 | L2 | Rejected-Finance Other than L1 | |
| 3 | L3₹34.9 L+₹22,491.31 (0.65%)Rejected-Finance 44 EKTA NAGAR MP 4 ROAD JABALPUR MP 482002 | JABALPUR | MADHYA PRADESH | 482002 | L3 | Rejected-Finance Other than L1 | |
| 4 | L4₹39.0 L+₹4.3 L (12.5%)Rejected-Finance AZAD NAGAR RANJHI JABALPUR MP 482010 INDEX NO E 106 JBP | JABALPUR | MADHYA PRADESH | 482010 | L4 | Rejected-Finance Other than L1 | |
| 5 | L5₹39.4 L+₹4.7 L (13.5%)Rejected-Finance DIWANBADA MANEGAON POST OFFICE KHAMARIA JABALPUR 482005 M P | JABALPUR | MADHYA PRADESH | 482005 | L5 | Rejected-Finance Other than L1 |
Tender Value
₹45.9 L
EMD Value
₹91,800
Closing Date
23 Sept 2023, 5:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (West) Jabalpur
Garrison Engineer (West) Jabalpur Supply Marg Post Box No.54 Jabalpur Cantt-482001 (MP)
PROVN OF FIRING POINT AT 300 MTR AT G RANGE AND ADDITIONAL/ALTERATION TO FIRING POINT AT 300 MTRS AT F RANGE AT GRC AND CERTAIN MINOR WORK IN THE AREA OF AGE B/R-II UNDER GE (WEST) JABALPUR
2023_MES_615864_1
8627/E8
Open Tender
Civil Works
Item Rate
180 days
GE (West) Jabalpur
As per tender documents
7 documents required · 7 mandatory
₹500
GE (West) Jabalpur
₹91,800
31 Oct 2023
26 Aug 2023
28 Sept 2023
28 Aug 2023
23 Sept 2023
9 Sept 2023
28 Aug 2023 - 4 Sept 2023
Amount
Demolition of Brick / Stone Masonry built in Cement Mortar including all quoins arches pillars etc complete all as specified and as directed.
Excavation in trenches not exceeding 1.5m wide and not exceeding 1.5m in depth for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out in Soft / Loose soil, complete all as specified and as directed.
Excavation over areas not exceeding 1.50 m in depth and getting out in Soft / Loose soil complete all as specified and as directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25cm thick of excavated soil complete all as specified and as directed. Note: A deduction of 10% shall be made from total computed volume of filling to cater in bulk irrespective of machinery used for ramming.
Removal of excavated material [Soil] to a distance not exceeding 50 m and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified and as directed.
Removal of excavated material [Soil] to a distance exceeding 1.5 KM but n exc 5.0 KM and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified and as directed.
Excavation in post holes each not exceeding 0.5 Cu.m, getting out in Soft / Loose soil, including returning, filling in and ramming earth or broken rubble mixed with earth around in layers not exceeding 25cm thick, watering and removing surplus soil to a distance not exceeding 50m and making good surface complete all as specified and as directed.
M & L for moorum/ red bajri filling under floors laid in layers not exceeding 15 cm thick, spread levelled and rammed / rolled including watering to required level and gradient complete all as specified and as directed.
M & L for hardcore of gauge not exceeding 63 mm of broken stones or boulders, deposited, spread and levelled in layers not exceeding 15 cm thick watered and rammed to a true surface in broken boulder complete all as specified and as directed.
M & L 50 mm thick sand filling under floors or in foundations including ramming, watering and consolidation complete all as specified and as directed.
M & L for PCC 1:4:8, Type D-2, using 40mm graded stone aggregate as in Foundation, Fillings, Mass concrete, Footings etc complete all as specified and as directed.
M & L for PCC 1:2:4, Type B-1, using 20mm graded stone aggregate as in Foundation, Fillings, Mass concrete, Footings etc complete all as specified and as directed.
M&L for PCC (1:3:6) type C-1 (using 20mm graded stone aggregate) as in surface channels, drains etc complete all as specified and as directed.
M&L for PCC (1:2:4) type B-1 (using 20mm graded stone aggregate) as in surface channels, drains etc complete all as specified and as directed.
M & L for PCC 1:2:4, Type B-1, using 20 mm graded stone aggregate as in Roof kerbs, Covings etc including weathering, slightly rounded or chamfered angles and throating complete all as specified and directed.
M&L for RCC M-25 (Design Mix) using 20mm graded stone aggregates as in foundation including raft footings foundation beams, plinth beams, base of columns etc basement slabs, under-reamed piles and mass concrete etc complete all as specified and directed
M&L for RCC M-25 (Design Mix) using 20mm graded stone aggregates as in retaining walls etc complete all as specified and directed
M&L for providing precast Reinforced cement concrete 1:2:4 type B-1 (using 20mm graded stone agg) for landings, cover slabs and similar articles with plain faces etc. with plain fair faces, including chamfers, weatherings, throating etc. and setting in mortar complete with joints to match the shade set in CM 1:4 including necessary form work complete all as specified and as directed.
M&L for extra forming fair finished drain or channel 60 cm inner girth in cement concrete, using extra cement, including form, moulds, mitred/stopped ends etc complete all as specified and as directed.
M&L for Brickwork with fly ash bricks, modular straight or curved on plan exc 6m mean radius, built in cement mortar (1:6) complete all as specified and directed.
Use and waste of form work to sides of concrete foundation, footings, bases of column, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter; for rough finished surfaces complete all as specified and as directed.
Use and waste of form work to sides of pillars, posts, struts, piers, columns of any shape / cross section for fair finished surfaces of concrete complete all as specified and as directed.
M&L for Mild Steel TMT steel bars of 10mm dia and over, cut to length, bent to shape required including cranking, bending, spirally for hooping, hooking ends and binding with annealed mild steel wire not less than 0.9mm dia or securing with clips or welded complete all as specified and as directed.
S&F rolled sections as in main and cross beams, hip and jack rafters; purlins,plates where connected to a common rafters, fixed with angle cleats or other connecting plates of Gde fe 410-0 or fe 250-0 complete all as specified and as directed.
S&F roof trusses (framed) trussed, purlins, crane gantries, rails and fastenings and heavy brackets framing (Beam, tee angle, channel or flat sections) including distance pieces cleats etc confirming to Fe 410W Gde 250 quality A complete all as specified and as directed.
S & F MS machine made screw bolts with hexagonal or square head one end and screwed other or screwed both ends, fitted with washers and one hexagonal or square nut exceeding 5 cm and not exceeding 10 cm long, dia of neck exceeding 5 mm but not exceeding 10 mm complete all as specified and as directed.
S & F MS machine made screw bolts with hexagonal or square head one end and screwed other or screwed both ends, fitted with washers and one hexagonal or square nut exceeding 10 cm and not exceeding 15 cm long, dia of neck exceeding 10 mm but not exceeding 15 mm complete all as specified and as directed.
S&F mild steel plates welded to MS pipe complete and confirming to Gde Fe 410-O or Fe 310-O complete all as specified and as directed.
M&L MS work as in wind ties for roof including securing bolts, drilling holes, notching for wire etc complete all as specified and as directed.
S&F hand rails, half rounded or other stock section or core for wooden hand rail straight portion, drilled and counter sunk for balusters, nosing to steps including embeding in concrete and screwing etc wind ties for roof including securing bolts; posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire etc; flat iron fillets (for securing wire mesh etc,) including all necessary drilling bolting or riveting, etc and similar work conforming to Fe410-0 or Fe 310-0 complete all as specified and directed.
S&F rolled mild steel plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, with riveted, bolted or weleded attachement confirming to Fe- 290 (Gde E-165) complete all as specified and as directed.
M&L prepainted 0.50 mm thick gavalume aluminium zinc coating AZ 150 GI based corrugated steel coloured Sheet in profile pattern having tensile strength of 550 Mpa as in roof covering & on chajjas fixed with self tapping screws etc all as specified and directed
M&L Pre-painted galvalume aluminium zinc coating GI based plain steel sheet 0.5mm thick of an colour having tensile strength of 550 Mpa as in roof covering /cladding to wall, fixed with self tapping screws as specified
M&L for 100mm thick PCC (1:2:4) type B-1 (using 20mm graded stone aggregate) as in paving/path finished fair and even complete all as specified and as directed.
M&L for 75mm thick PCC 1:4:8 type D2 (using 40mm graded stone aggregate) as in sub base complete all as specified and directed
M&L for 80mm thickness of M 35 Grade Machine pressed precast concrete interlocking paver block of any shape and size with grey cement and pigment, confirming to IS 15658-2006 complete all as specified and as directed.
M & L rendering 15mm thick to brick / concrete surfaces in Cement Mortar 1:6, surfaces finished even and smooth without using extra cement complete all as specified and as directed.
Preparation of new plastered or unplastered surfaces and applying three coats of white wash on wall surfaces complete all as specified and as directed.
M & L for two coats of synthetic enamel paint over one coat of red oxide primer on new steel surfaces over 10cm width or girth including preparation of surfaces complete all as specified and as directed.
S&F PVC (SWR) pipes 75mm bore single socketed in any length with rubber ring joints laid in floors, trenches complete all as specified and as directed.
J.P ENTERPRISES
kamakshi construction
B G PANDEY AND BROTHERS
C L BHATIA
Tiki Water proofing Co
ANAMIKA CONSTRUCTION
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .