| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹42.8 LAccepted-AOC | ₹42.8 L Quoted ₹43.6 L | L1 | Accepted-AOC Lowest bid |
| 2 | L2₹46.8 L+₹3.1 L (7.14%)Rejected-Finance H M APARTMENT 4C S J ROAD ATHGAON GUWAHATI 781001 | GUWAHATI | KAMRUP METRO | ASSAM | 781001 | ₹46.8 L+₹3.1 L (7.14%) | L2 | Rejected-Finance Other than L1 |
| 3 | L3₹46.9 L+₹3.3 L (7.47%)Rejected-Finance OPP BSF GATE NO 3 AZARA GUWAHATI 17 ASSAM | ₹46.9 L+₹3.3 L (7.47%) | L3 | Rejected-Finance Other than L1 |
| 4 | L4₹46.9 L+₹3.3 L (7.51%)Rejected-Finance AZARA NEAR HOSPITAL GUWAHATI 781017 ASSAM | KAMRUP METRO | ASSAM | 781017 | ₹46.9 L+₹3.3 L (7.51%) | L4 | Rejected-Finance Other than L1 |
| 5 | L5₹47.3 L+₹3.6 L (8.34%)Rejected-Finance | ₹47.3 L+₹3.6 L (8.34%) | L5 | Rejected-Finance Other than L1 |
Tender Value
₹40 L
EMD Value
₹80,000
Closing Date
25 Sept 2024, 6:00 pmClosed
GE (AF) Borjhar
Garrison Engineer (AF) Borjhar, Military Engineer Services, Guwahati Airport- PO, Borjhar Airport, Guwahati, Assam, Pin- 781015 Tele 0361 - 2840127
Repair To Plumbing, Fittings, Roof Sheeting, False Ceiling, Wall Panelling and Chajja Repair at 19 Wing, AF under GE (AF) Borjar
2024_MES_671690_1
8413/BOR/E8
Open Tender
Civil Works
Item Rate
270 days
GE (AF) Borjhar
MES Contractor enlisted as Class D category a(i) having deposited Standing Security of Rs 50000.00 with dept. Contractors not enlisted in MES should meet the MES enlistment criteria corresponding to appropriate class and category.
7 documents required · 7 mandatory
₹500
GE (AF) Borjhar
₹80,000
Yes
28 Mar 2025
4 Sept 2024
27 Sept 2024
4 Sept 2024
25 Sept 2024
18 Sept 2024
Amount
Dismantling water tanks of any description exceeding 250 ltrs and not exceeding 500 ltrs capacity and removing from site complete as specified and directed.
Dismantling water tanks of any description exceeding 500 ltrs and not exceeding 1000 ltrs capacity and removing from site complete as specified and directed.
S & F 500 liters rotational moulded polyethylene water storage tank, double layered (cylindrical vertical with closed top cover) as per IS-12701-1996, hoisted and fixed in position including necessary arrangements for fixing inlet, outlet and ball valve (float valve) complete all as specified and directed.
S & F 1000 litres rotational moulded polyethylene water storage tank, triple layered (cylindrical vertical with closed top cover) as per IS-12701-1996, hoisted and fixed in position including necessary arrangements for fixing inlet, outlet and ball valve (float valve) complete all as specified and directed.
S & F in repairs lid for polyethylene water storage tank exc 250 ltr and not exceeding 500 ltrs including fixing PTMT nuts/binding wire complete all as specified and directed.
S & F in repairs lid for polyethelene water storage tank exceeding 500 ltr and not exceeding 1000 ltrs including fixing PTMT nuts/binding wire complete all as specified and directed.
S & F in repairs lid for polyethelene water storage tank not exceeding 1000 ltrs including fixing PTMT nuts/binding wire complete all as specified and directed.
S&F in repairs 15 mm dia gun metal, globe or gate valve, with iron wheel head, screwed both ends for iron pipe complete all as specified and directed.
S&F in repairs 20 mm dia gun metal, globe or gate valve, with iron wheel head, screwed both ends for iron pipe complete all as specified and directed.
S&F in repairs 25 mm dia gun metal, globe or gate valve, with iron wheel head, screwed both ends for iron pipe complete all as specified and directed.
Taking up or down steel tubing 15 mm bore and connections including cleaning for refixing or removing from site complete all as specified and directed.
Taking up or down steel tubing 20 mm bore and connections including cleaning for refixing or removing from site complete all as specified and directed.
Taking up or down steel tubing 25 mm bore and connections including cleaning for refixing or removing from site complete all as specified and directed.
Refixing old steel tubing, 15 mm bore, and connections with new or old position (Walls, ceiling, floors etc.) complete all as specified and directed. Note : Steel tubes obtained from Serial item No. 11.00 above shall be used under this item.
Refixing old steel tubing, 20 mm bore, and connections with new or old position (Walls, ceiling, floors etc.) complete all as specified and directed. Note : Steel tubes obtained from Serial item No. 12.00 above shall be used under this item.
Refixing old steel tubing, 25 mm bore, and connections with new or old position (Walls, ceiling, floors etc.) complete all as specified and directed. Note : Steel tubes obtained from Serial item No. 13.00 above shall be used under this item.
Supply and laying 15 mm bore tubes, galvainzed steel, medium grade with all fittings and fixed complete on walls and ceilings or laid in floors all as specified and directed.
Supply and laying 20 mm bore tubes, galvainzed steel, medium grade with all fittings and fixed complete on walls and ceilings or laid in floors all as specified and directed.
Supply and laying 25 mm bore tubes, galvainzed steel, medium grade with all fittings and fixed complete on walls and ceilings or laid in floors all as specified and directed.
S&F in repairs 20 mm bore ball valve high pressure of PTMT with epoxy coated aluminium rod & high-density plastic ball screwed for iron pipe and fixed. (Minimum weight 210 gms) complete all as specified and directed.
Cutting holes in brick walls for inserting Water pipe line and making good dismantled portion by filling cement concrete 1:3:6 Type C-1 exceeding half brick but not exceeding one brick including existing surface finishes complete all as specified and directed
Demolition of brick work or stone masonry built in cement mortar including all quoins, pillars etc complete all as specified and as directed.
M&L brick work with sub class B bricks burnt straight or curved on plan exceeding 6 M mean radius built in cement mortar 1:6 complete all as specified and as directed.
M & L for rendering 15mm thick in cement mortar 1:4 on fair faces of brick concrete on internal surface finished even and smooth without using extra cement complete all as specified and directed.
M&L for applying three coats of white wash on walls including preparation of newly plastered surfaces complete all as specified and directed.
S&F in repairs PVC connection 15 mm dia 600mm long with 2 Nos PVC check nuts with washer complete all as specified and directed.
S&F in repairs PVC connection 15 mm dia 450mm long with 2 Nos PVC check nuts with washer complete all as specified and directed.
S&F in Pillar taps 15mm dia fancy type with capstan heads, chromium plated screwed down high pressure with or without lettered HOT or COLD with long screwed shanks and fly nuts, screwed for iron pipe and fixed complete all as specified and directed.
S&F in repair pillar tap standard of PTMT any colour high pressure screwed for iron pipe of 15 mm bore and fixed (Minimum weight 15mm 110gms) complete all as specified and directed.
S&F in repairs 15mm dia of fancy type chromium plated Angle stop valves, cast copper alloy with crutch or butterfly handle, screwed down, screwed for iron pipe or for unions and fixed complete all as specified and directed.
S&F in repairs of 15 mm bore stop valve, cast copper alloy, screwed down, high pressure with crutch or butterfly handle, screwed both ends for iron pipe or for union and fixed complete all as specified and directed.
S&F in repairs 15 mm dia bib tap cast copper alloy CP fancy type with capstan head long body and cup screwed down for iron pipe all complete all as specified and directed.
S&F in repair for Brass chromium plated shower rose 125mm size with arm 15 mm bore complete all as specified and directed by Engineer-in-charge .
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified and directed.
M & L for Glazed ceramic tiles in vertical surface 300x 450x 6-7mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match over 15mm thick cement mortar 1:4 rendering as specified and as directed. Make: Kazaria/Somany or equivalent.
S&F Non skid Ceramic tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.06 sqm but not exceeding 0.11 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over 15mm thick cement mortar 1:4 bedding, all as specified and as directed. Make: Kazaria/Somany or equivalent.
S & F in repairs viterous China Wash Hand Basin white, flate back, size 550 x 400mm including 15mm dia pillar tap, cast copper alloy, with capstan head CP, screwed down high pressure with or without letter Hot or Cold with long screwed shank and fly nut including PVC water pipe 32mm bore and PVC connection suitable for 15mm bore pipe 60cm long with nut and washers at both ends and CP waste coupling, including mild steel brackets, made out of 25 by 25 by 3mm thick angle iron of required length fixed to wall with PCC type B-0 (1:2:4) including cutting for a pinning in a brackets complete all as specified and directed by Engr-in-Charge.
S&F in repairs sink with drainage board made of stainless steel 1mm thick for kitchen with plugs, washers and wastes, including fixing with cast iron cantilever brackets, bedding in cement mortar on to dwarf wall, connecting union to pipe, overall minimum size 915mm x 460 mm with bowl size 410mm x 330mm x160 mm including 32mm dia waste pipe of polythelene of low or high density, 32mm bore chromium plated brass waste fitting with long screwed shanks and fly nuts, flange end bedded in red lead cement & other end fixed, making holes in walls for brackets and fixed in CM (1:3) or PCC (1:2:4) type B0, complete including taking down old unserviceable sink complete all as specified and directed.
Cutting of saplings of any size from bulidings in any situation & at any height including removal of roots from roof/wall including applying root killer chemical as per manufacturers instructions and making good disturbed portion with PCC 1:2:4 Type B0 (using 12.5mm graded stone aggregate) complete finish with cement mortar (1:4) as specified and as directed.
S & F in repairs for PVC low level flushing cistern 10 Ltr capcity Valveless duel symphonic action type, flushing cistern , low level white, with inlet ball valve flat and handle including PVC flush pipe 32mm bore and mild steel brackets made out of 25 by 25 by 3mm thick angle iron of required length fixed to wall with PCC type B-0 (1:2:4) complete all as specified and directed .
S & F in repairs health faucet ABS body mild steel chromium plated for 15mm dia, 1.25 meter long flexible tube and ABS wall hook including making connections and fixed in position complete in all respect as specified and directed.
S & F in repairs viterous China Wash down water closet Pan "Pedestal Pattern" white with seat cover white closet pattern with flat battom and cover mild steel chromium plated or aluminium anodised hinging device and joints etc and connection to drain, flushing, pipe, anti symphonage pipe and fixing arrangements with fixing bolts etc including making good the disturbed portion of floor in cement concerete 1:2:4 type (B-0) complete all as specified and directed.
S & F in repairs squatting pan vitreous china "orrisa pattern" of Size 580mmx440mm "white" with integral foot rest (Excluding flushing cistern and flush pipe) including provision of cement concrete bedding, connection to trap and to flushing pipe, anti-syphonage pipe etc complete making good to floor complete all as specified and directed.
S & F in repairs in repairs viterous china Urinal half stall type, white including providing & fixing plugs, beddinjg urinal against wall in cement mortar (1:2) securing to plugs with & incl 60mm long brass screws, pointing around urinal back in cement with & including PTMT grating and union for discharge pipe including waste pipe of polythelene of low or high density or PVC 32mm dia, complete all as specified & directed.
S & F in repairs for PVC waste coupling 32mm dia PTMT (half or full threaded) suitable for WHB/Sink (min weight 450 gms), completed all as specified & directed
S&F in repairs in repairs sheet glass shelf assembly consisting of 5.5mm thick sheet glass shelf 12cm wide with chromium plated bracket guard and railing 600mm long complete all as specified and directed.
S & F in repairs CP Tubular Towel Rail 600mm long including Chromium Plated brass screws and wooden/plastic cleats (Minium weight 90 gm) complete all as specified and directed.
S&F in repairs CP Soap dish, approximate size 160X160X90mm complete all as specified & directed.
S&F in repairs Toilet paper holder, CP box type complete all as specified & directed
S&F in repairs grating doom 125mm dia with waste hole of PTMT and CP complete all as specified & directed (Minimum weight 40 gm)
M & L for reparing of RCC projection chajja, roof, roof facia, celing by scrapping, cutting derusting and cleaning exposed reinforcement surface of damaged loose RCC surface and applying neat cement slurry @3 Kg/Sqm and filling the surface with cement plaster 1:3 one or two layers as reqd or PCC 1:2:4 (B-0) using 12.5mm aggregate as directed by engr in charge with or withour facia and smooth finished and smooth edges incl two coat of finished to match with the existing surface of wall finishes at any height and any height and in any situation including necessary form work complete all as specified and directed.
Demolition of cement concrete (unreinforced) of any description and in any position not otherwise specifically provided for complete all as specified and directed.
M&L for PCC 1:2:4 type B-2 using 40 mm graded stone aggregate in in foundations, filling and mass concrete complete all as specified and directed.
Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified and directed.
M&L for Mild steel work in tubular trusses including special shaped washers etc complete using ERW or induction butt welded tubes conforming to IS-1161-1979 grade St-240, complete all as specified and directed by Engineer-in-Charge. Note : The cost of nuts, bolts & washers for jointing to the members of trusses shall be deemed to be included in the quoted unit rate by tenderer. Nothing extra shall be admissible on this account.
M&L for preparation of new steel and iron surfaces of any description over 10 cm in width or girth and applying two coats of synthetic enamel paint of approved tint over a coat of zinc chrome primer, complete all as specified & directed by Engr-In-Charge.
Dismantling AC sheet (Corrugated, Semi corrugated etc) as in roofs etc complete all as specified and directed.
S&F for Galvalume zinc coated GI based corrugated sheet shall be 0.50mm thick (total coated thickness), 550 Mpa minimum, yield strength. It shall be coated with hot dip alloy of 55% Aluminium 43.5% Zinc 1.5% Silicon and finished with resin coat on both surfaces @ 150 gm/sqm of coating (total both surfaces) having overall width and laid width as specified and shall be fixed using hot dip galvanized, self drilling and self tapping screws neoprene and EPDM washers all as specified and directed. Notes : Contractor shall produce necessary test certificate of the manufacturer to the Engr-in-Charge before incorporation in the work. Irrespective of manufacturer's test certificate, Independent tests shall also be carried out by the contractor without any extra cost to the Deptt as per relevant IS specifications and galvalume sheets with satisfactory test results shall only be incorporated in the work and the quoted rate is deemed to include carrying out necessary tests and submission of reports. Contractor shall submit the test reports alongwith RAR failing which no payment shall be made against this item and nothing extra is admissible on this account.
S&F for Galvalume zinc coated GI based plain sheet shall be 0.50mm thick (total coated thickness), 550 Mpa minimum, yield strength. It shall be coated with hot dip alloy of 55% Aluminium 43.5% Zinc 1.5% Silicon and finished with resin coat on both surfaces @ 150 gm/sqm of coating (total both surfaces) having overall width and laid width as specified and shall be fixed using hot dip galvanized, self drilling and self tapping screws neoprene and EPDM washers. all as specified and directed.
Dismantling of Wall and ceiling boards (fibre, pulp, insulation etc.) or insulation boards/ slabs/ blankets, any thickness, including cover fillets complete all as specified and directed .
M&L for Non asbestos fibre cement building boards 4-6mm in thickness fixed or laid/ inserted to timber / GI / Aluminium frame work with screws along with Anodised aluminium snap grid frame work for false ceiling Size of grid 605 x 605mm all as specified and directed.
S&F solid PVC Wall Lining consisting of 5mm thick wood grain printed PVC sheet inclusive of solvent cement/adhesive and fixing at site on PVC/wooden frame as per specifications and drawing given in SSR complete all as specified and directed. Note : PVC Fillets shall be measured and paid for separately.
S&F 5mm thick PVC sheet fillet of width 35mm for wall paneling inclusive of fixing on to wall to make PVC Frame as per specifications and drawing given in SSR complete all as specified and directed.
M&L for second class soft wood plain fillets, square, rectangular or triangular in section, clean sawn, secured with nails or brads, sectional area exceeding 6 sqcm and not exceeding 13 sqcm including tarring complete all as specified and directed.
M&L for 75 mm thick PCC (1:4:8) type D2 using 40 mm graded crushed stone aggregate as in sub base, surface finished fair and even complete all as specified and as directed.
M&L for Prepolished chequered cement concrete tiles with grey cement & pigment of size 30cmx30cmx20 to 22mm thick set & jointed with cement slurry over & including 15 mm thick bedding layer of cement sand mortar (1:6) and pointed with grey cement complete all as specified and as directed by Engineer-in-Charge.
Labour only for day to day petty repairs works like repair/dislocked bib taps/Angle cock, adjustment of float valve in flushing cistern, PVC water tank, repair to water tightness of pipe (15mm-25mm), cleaning of air pressure vacume in water pipes and free for fixing of bib tap , flushing cistern received from MES store and other plumber related petty works as and when required to attened complaints as per complaint cell complete all as specified and directed. Note : One plumber alongwith helper shall be be deployed by the contractor for the period of 08:00Hrs as per required base.
M & L for cleaning of all loose dirt and dust from roof surfaces and applying roof treatment as under :- (a) 10 mm thick plastering in CM (1:4) using 100 % coarse sand on roof / parapet walls with WPC @ 3 % by weight of cement. (b) Applying a coat of bitumenous primer @ 0.40 litre/Sqm on prepared surfaces and allow to dry. (c ) Applying a coat of hot blown bitumen 85/25 grade @ 1.20 Kgs/Sqm over primer. (d) Supply and laying of 3mm thick (Minimum) polymeric water proofing membrane weighing not less than 3 Kgs/Sqm, black finish reinforced with non woven polyster matt with help of torching with proplane or abutane gas using torch with minimum 75mm side overlap and 100mm end overlap as per manufacturers instructions. (e) Applying a tack coat of hot blown bitumen grade 85/25 @ 10.20 Kgs/Sqm . (f) Blinding with dry coarse sand @ 0.50 to 1.0 Kg /Sqm dusted over bitumen. Note : The net area of water proofing treatment shall be measured without any extra allowance for laps & portion inserted in groove which shall be deemed included in the quoted Rates. Security from total amount of roof treatment work. Contractor shall produce necessary test certificate of the manufacturer to the Engr-in-Charge before incorporation in the work. Independent tests shall also be carried out by the contractor without any extra cost to the Deptt as per relevant IS specifications and membranes with satisfactory test results shall only be incorporated in the work and the quoted rate is deemed to include carrying out necessary tests and submission of reports. Contractor shall submit the test reports alongwith RAR failing which no payment shall be made against this item and nothing extra is admissible on this account.
M/S. SUBHAS CONSTRUCTION CO. (BID ID -3107727)
M/s Dhani Enterprise (BID ID -3102058)
Anupam Das (BID ID -3112094)
M/s Dhruv Enterprises (BID ID -3102568)
M/S PRASANTA MAHANTA (BID ID -3112594)
Garg Brothers (BID ID -3111104)
M/s JK Jangid and Company (BID ID -3110032)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .