RequiredExperience with Government Bid to RA enabled No Door Frame Metal Detector Dfmd Security Metal Detector ( 2 ) Technical Specifications * As per GeM Category Specification Specification Specification Name Values Bid Requirement (Allowed Values) TYPE/CAPACITY Type of usage Indoor Indoor Detection Zones Multiple Zone Multiple Zone Function Detects Ferrous
RequiredNon- Ferrous and alloy metals concealed in the body of a person when passsed through the arch way * 1/7 Number of Horizontal Detection Zones covering full Height 8 8 Capacity/throughput rate (person/min) 10 or more * False Alarm rate (%) 0.1 * DIMENSIONS/WEIGHT Passage Height 2050 * Passage Breadth 750 * Passage Width 590 * Weight of the equipment Not more than 90 Kg * DOOR FRAME CONSTRUCTION Construction of Door Frame (Walk-through Arch) Light weight
Requiredrigid
Requiredlaminated side panels and cross piece with ABS plastic boots for panel protection * Material of Walk- through Arch POLYCARBONATE POLYCARBONATE Provided with base wheels for easy mobility Yes Yes Provided with a floor panel to attach both side panels to give stability & rigidity to the structure Yes Yes Ramp over the floor panel - Covered with synthetic carpet for long life Yes Yes Water proof Yes Yes Weather proof Yes Yes DETECTION Metals detectable Ferrous
RequiredNon-Ferrous
RequiredFerrite & Alloys * Uniform Detection from top to bottom Yes * Capable of Metal Detection in all orientations Yes * Detect multiple objects of various size
Requiredweight and shape in all the zones simultaneously from head to toe Yes * Capable of Metal Detection in walking speed of interception Yes * 2/7 Performance independent of the speed of person passing through Yes * ALARM/INDICATION DISPLAY Audio-Visual indication on detection at side panels and control panel Yes * Audible Alarm on detection with adjustable volume Yes * Bar Display to indicate Metal location w r t Height on person Yes Yes Audio-Visual Low Battery indication Yes * Back-lit Display LED * SENSITIVITY Operational Frequencies User selectable * Number of User Selectable frequencies 14 * Adjustable Sensitivity Yes * Number of Sensitivity Levels/Steps 10 * Uniform Sensitivity in all zones Yes * Calibration Both manual and Auto Calibration * SECURITY Provision to secure access to the control unit by a pass word protected alpha numeric keypad Yes * Re-setting after alarm condition Re-set itself (auto) within 3 Seconds * Walk/Stop indicator for traffic control Yes * Control Panel Easy accessible control panel
Requiredwith modular design and standard plugs and connectors. Adjustable controls should only be activated on insertion of a removable key and or by password. * User friendly self- testing diagnostics to Yes * 3/7 identify faulty condition INTERFERENCE SUPPRESSION REJECTION Automatic synchronization for DFMDs Do not interfere with adjacent installed DFMDs located close to each other upto a distance of 1 * Static Metal Compensation Not affected by heavily reinforced floors/roof tops/walls Yes * High discrimination between small masses and personal metallic objects Yes * Not affected by external RF transmission and EMI (Electro Magnetic Interference) Yes * Not affected by by interference
Requiredwhich is mains-borne or radiated by external source Yes * Not affected by the operation of radio
RequiredMobile phones
Requiredwalkie- talkie sets
RequiredX-ray monitors etc within a distance of one meter Yes * Not affected by moving metallic items such as trolleys
Requiredopening closing of metallic gate etc
Requiredone meter away from the archway Yes * HEALTH & SAFETY Harmless to wearers of pacemakers
Requireddefibrillators or other vital support systems
Requiredpregnant women and magnetic storage media Yes * Not affected by infrared
Requiredultraviolet
Requiredelectromagnetic or RF radiation Yes * Conform to international security Yes * 4/7 standards of Safety Radiation Harmless to magnetic media
Requiredelectronic devices
RequiredFilm safe and Data safe Yes * ENVIRONMENTAL Operating Temperature Range (Degree C) Minus 20 to Plus 55 Degree C Minus 20 to Plus 55 Degree C Operating Humidity - Non condensing (RH) (%) 94.5 * POWER SUPPLY BATTERY Source of Power Operated by AC mains supply and alternatively by rechargeable battery * Power Supply 220 V +/-10% VAC * Battery Re-chargeable
Requiredmaintenance free
Requiredinternal battery with charger Re-chargeable
Requiredmaintenance free
Requiredinternal battery with charger Battery Back-up in full function (hours) 12 12.0
Required12 ACCESSORIES One Standard Test Piecec for each machine for testing during commissioning maintenance Inclusive in the scope of supply * Training tools- Charts
Requiredslides
Requiredtraining brochure
Requiredtraining work model
Requiredblowup diagram
Requiredvideo films on demonstration and use etc Inclusive in the scope of supply * Technical manual giving full description of the item
Requireduser's handbook and literature Yes * Practical training At least one day in each quarter of the year continuing during warranty period At least one day in each quarter of the year continuing during warranty period Availability of Spares for a period of 7 years after the warranty period Yes Yes Ruggedized polypropylene shock Yes Yes 5/7 proof container compliant to IP 65 or better for safe transportation of the equipment WARRANTY Warranty (Years) 3 3.0
Required3 CERTIFICATION Availability of Test Report from NABL ILAC accredited or Central Government Lab to prove conformity of products to the specification Yes Yes
RequiredNo Test Report Number & Date - * Name & address of the Lab - * * Bold specifications are the golden parameters. * Bidders may note that In respect of non-golden Parameters
Requiredthe specifications 'Values' chosen by Buyer will generally be preferred over 'Bid requirement ( allowed Values) by the Buyer.