Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.8 CrAccepted-AOC URBAN ESTATE URBAN ESTATE JIND 126102 | JIND | JIND | HARYANA | 126102 | ₹1.8 Cr | L1 | Accepted-AOC Accepted |
| 2 | L2₹1.9 Cr+₹14.5 L (8.10%)Rejected-AOC 443 V P O LIWAN 132001 | KARNAL | HARYANA | 132001 | ₹1.9 Cr+₹14.5 L (8.10%) | L2 | Rejected-AOC Rejected |
| 3 | L3₹2.0 Cr+₹19.2 L (10.7%)Rejected-AOC 7 WARD NO 7 PURANI ANAJ MANDI GOHANA 131301 | GOHANA | SONIPAT | HARYANA | 131301 | ₹2.0 Cr+₹19.2 L (10.7%) | L3 | Rejected-AOC Rejected |
| 4 | L4₹2.4 Cr+₹56.9 L (31.6%)Rejected-AOC | ₹2.4 Cr+₹56.9 L (31.6%) | L4 | Rejected-AOC Rejected |
Tender Value
Refer Docs
EMD Value
₹4.1 L
Closing Date
4 Mar 2022, 4:00 pmClosed
Rohit
PHED No 1 Rohtak
Singhpura Kalan- Providing Functional House Hold tap connection (FHTC), laying of balance pipeline an Independent canal based water works in village Singhpura Kalan, Laying, Jointing, cutting of RCC NP-2 pipe inlet channel, construction of brick mas
2022_HRY_209544_1
Singhpurar, Prov Functional Household Tap Connect
Open Tender
Civil Works
Works
450 days
Rohtak
Please refer Tender documents.
2 documents required · 2 mandatory
₹15,000
₹4.1 L
28 Mar 2022
24 Feb 2022
4 Mar 2022
24 Feb 2022
4 Mar 2022
24 Feb 2022
Amount
RAW WATER PUMP SETS Supply & Eraction of Horizontal spindle split casing type pumping sets of following duties directly coupled to AC squirrel cage induction type motor with accessories as described in Schedule No II complete in all respect with priming arrangement with complete base frame A) For Proposed Water Works800 LPM with 12.5 M. Head & 5 BHP For Raw Water
Supply and jointing three core cables of approved make with bare bunched copper conductor insulated and sheathed with PVC for Clear Water & Raw Water pump motors /fountain lights etc with voltage grade 1100 volts marked with IS:694, 1990 including cost of jointing, materials as well as carriage, loading, unloading etc. complete in all respect up to the entire satisfaction of Engineer- in-ChargeSupply and jointing three core cables of approved make with bare bunched copper conductor insulated and sheathed with PVC for Clear Water & Raw Water pump motors /fountain lights etc with voltage grade 1100 volts marked with IS:694, 1990 including cost of jointing, materials as well as carriage, loading, unloading etc. complete in all respect up to the entire satisfaction of Engineer- in-Charge10 Sq.mm
Supply, erection, testing and commissioning of wall mounted electrical LT panel board, fabricated from 16 SWG CRCA sheet duly stouted with suitable angle iron frame work and completely powder coated of approximate size 1200x900mm and 400mm deep having following item:- For Raw water pump set 800 LPM x 12.5 M. Head = 2 Nos. (One for Each pump set) at Water Works Gharauthi A Main switch 32 Amp 1 No. (L&T siemens, ABB). B Volt meter 100x100mm range 0 to 500 volt= 1 No. (AE/KAPPA/L&T)C Amp. Meter 100x100mm range 0 to 100 volt= 2 No. (AE/KAPPA/L&T)D CT 100/3 No. (AE/KAPPA/L&T)E VSS & ASS 1 No. each No. of approved make F SSP 4 No. of approved make/ minilacG Motor starter star delta 1 Nos. for 800 LPM x 12.5 M Head motor (L&T, Siemens, ABB)H Capacitor KVAR as per site requirementI Indicating Lamp One SetJ Change over Switch 63 Amp. = 1 No.
Supply, erection, testing and commissioning of wall mounted electrical LT panel board, fabricated from 16 SWG CRCA sheet duly stouted with suitable angle iron frame work and completely powder coated of approximate size 1200x900mm and 400mm deep having following item:-For Clear Water pump set 800 LPM x 45 M. Head = 2 Nos. (One for Each pump set) at Water Works Gharauthi A Main switch 32 Amp 1 No. (L&T siemens, ABB).B Volt meter 100x100mm range 0 to 500 volt= 1 No. (AE/KAPPA/L&T)C Amp. Meter 100x100mm range 0 to 100 volt= 2 No. (AE/KAPPA/L&T)D CT 100/3 No. (AE/KAPPA/L&T)E VSS & ASS 1 No. each No. of approved make F SSP 4 No. of approved make/ minilacG Motor starter star delta 1 Nos. for 800 LPM x 45 M Head motor (L&T, Siemens, ABB)H Capacitor KVAR as per site requirementI Indicating Lamp One SetJ Change over Switch 63 Amp. = 1 No.
Operation and Maintenance for the complete scope of work mention in the DNIT (Disinfection material supplied by the PHED) as per schedule-IV for a period of 5 year after 12 months during defect liability period 3 months trial run (will be charged to the A/mic estimale). Operation and maintenance during defect liability period (operation only)
Operation and maintenance during 1st year afler defect lability period.
Operation and maintenance during 2nd year
Operation and maintenance during 3rd year
Operation and maintenance during 4th year
Operation and maintenance during 5th year
Bidder Name
Amount
Krishan Kumar(GSTN-06ATZPK0120H1ZQ)
Sunil Kumar Bansal(GSTN-NA)
SANJAY KHARB CONTRCATOR(GSTN-NA)
VINAY KUMAR CONTRACTOR(GSTN-NA)
SANJAY KHARB CONTRCATOR
Krishan Kumar
VINAY KUMAR CONTRACTOR
Krishan Kumar
Sunil Kumar Bansal
VINAY KUMAR CONTRACTOR
stage.html
html • 0.05 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .