Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹47.3 LAccepted-AOC | L1 | Accepted-AOC Lowest and reasonable | |
| 2 | L2₹52.5 L+₹4.4 L (9.17%)Rejected-Finance 245A 7A 1 JAYANTIPUR GOKUL AVAS YOJANA SULEM SARAI ALLAHABAD PRAYAGRAJ | PRAYAGRAJ | PRAYAGRAJ | UTTAR PRADESH | 211011 | L2 | Rejected-Finance Higher than L1 | |
| 3 | L3₹55.3 L+₹7.2 L (14.9%)Rejected-Finance 13 R N BAHUGUNA MARKET HASTING ROAD PRAYAGRAJ | PRAYAGRAJ | PRAYAGRAJ | UTTAR PRADESH | 211001 | L3 | Rejected-Finance Higher than L1 | |
| 4 | L4₹58.7 L+₹10.6 L (22.0%)Rejected-Finance | L4 | Rejected-Finance Higher than L1 |
Tender Value
₹61 L
EMD Value
₹1.2 L
Closing Date
10 May 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
CWE(AF) Bamrauli
HQ CWE(AF) Bamrauli, Prayagraj, PIN - 211012
SPECIAL REPAIR TO VCBs AND RING MAIN WORK
2023_MES_587420_1
87266/E8
Open Tender
Electrical and Maintenance Works
Item Rate
182 days
Bamrauli
As per NIT
8 documents required · 8 mandatory
₹1,000
GE(AF) Bamrauli
₹1.2 L
Yes
23 May 2023
29 Mar 2023
12 May 2023
29 Mar 2023
10 May 2023
26 Apr 2023
29 Mar 2023 - 8 Apr 2023
Amount
Material and labour for inspection/servicing /testing by each Breaker of line circuit breaker, control panel including CT, PT and relays in control panel of Indoor type Vaccum Circuit Breaker of capacity 630 to 800 Amps and rating 36 KV complete as per followings :-
(a) Details of servicing required in each breaker :- (i) Checking of Closing/Tripping coil assembly (ii) Adjustment of mechanism if required (iii) Clean the circuit breaker to remove dust and dirt (iv) Apply a small amount of oil to rotary sections, sliding surfaces, pins, coupling section, etc.use grease for the operating shaft and bearings, and machine oil for other parts. (v) Check for rust and wear.
(vi) Checking of spring charge mechanism (vii) Visual check for rust and deformation. (viii) Check for loosened bolts and nuts, broken spring washers and snap pins etc. (ix) Check for loosened connections, rust, damaged lead wires. (x) Checking of control circuit & tighten the connections if any. (xi) Check close & trip coil.
(xii) Replacement of Dashpot/shock absorbers . (xiii) Replacement of carbon brush of spring charging motor (xiv) Cleaning of porcelain bushing (xv) Checking of limit switch
(b) The following test shall be carried out:- (i) Primary Injection Test of outdoor CT / PT (ii) Closing & Opening Timing Test for all three poles. (iii) IR Test with megger in open and closed condition. (iv) Contact resistance test for all three poles (v) Closing coil resistance (vi) Tripping coil resistance.
(c) Testing of following relays of control panel with Secondary Injection Kit ,checking and programming of relay :- (i) Over current and earth fault relay (ii) Line diffrential relay
(d) Testing of followig Aux relay:- (i) DC Supply supervision relay. (ii) Trip Circuit suprvision relay (iii) PT Fuse failure relay (iv) Master trip relay (v) Under voltage relay (vi) Over voltage relay
Note:- (i) The wk shall be carried out from auth Rep/ Engineer of Crompton Greaves/Alstom. (ii) Caliberation of relays to be done from Rep/ Engineer ofCrompton Greaves/Alstom.
Supply, installation and commissioning of FCBC (CVCC) charger cum DC 24 V tripping unit in double compartment, bottom compartment to house 02 Nos 12 V, 100 AH of make Exide/Panasonic, SMF batteries and upper compartment to have CVCC charger, including making connections with suitable size of copper cable and with following specifications :-
(i) Type – CVCC (Constant voltage constant current) (ii) Rated input voltage – 230 Volts AC (iii) Input voltage tolerance= minus 15% & plus10% (iv) Rated input frequency +5% (v) Output voltage = 27.5V DC for 24 V battery bank. (vi) Output current = 0 to 24 Amps
(vii) Primary = Normal step down (viii) Secondary rectification = full wave thirstier controlled (ix) Surge suppression time = < 5 pico seconds (x) Ripple filtration – LC (20000 mfd or as required) (xi) Spike suppression energy – 20 Joules (xii) DC reverse polarity protection – Electronically/relay/contactor (xiii) Short circuit protection – Electronically / MCB
Supply only bushbar spout for trolly mechanism 11 KV VCB, complete all as specified & directed
Supply only charging gear for trolly mechanism 11 KV VCB, complete all as specified & directed
Supply only operating mechanism for breaker 11 KV VCB complete all as specified & directed.
Supply only tetlon hexagonal interlocking bush 11 KV VCB complete interlocking with strip complete all as specified & directed
Supply only ON push button for 11 KV VCB complete all as specified & directed
Supply only OFF push button for 11 KV VCB complete all as specified & directed
Supply only ON/OFF Indicator for 11 KV VCB complete all as specified & directed
Supply only OFF load isolator with earth switch mechanism for 11 KV VCB complete all as specified & directed
Supply only Z type lever of OFF push button for 11 KV VCB complete all as specified & directed
Supply only Z type lever of ON push button for 11 KV VCB complete all as specified & directed
Supply only trip coil only Y1 control volt 24 VDC for 11 KV VCB complete all as specified & directed
Supply only close coil only Y2 control volt 24 VDC for 11 KV VCB complete all as specified & directed
Supply only spring charging motor with gear 24 VDC for 11 KV VCB complete all as specified & directed
Supply only standerd spring charging motorised kit for V module for 11 KV VCB complete all as specified & directed
Supply and fixing in repair power pack SMPS input 110 Volt AC with PNE 50 Hz and output 110 volt DC with battery complete suitable for 11 KV HT VCB, complete all as specified & directed.
Supply and fixing in repair HRC fuses 02 Amp to 05 amp for 11 KV VCB all as specified & directed.
Disconnection of all electrical connection and taking down old defective unserviceable 11 KV potential transformer (PT) and S&F new PT 3 Phase, dry and draw out type 11 KV/110 volts with suitable VA burden per phase, accuracy class 0.5 complete with HT & LT HRC fuses for primary and secondary in vaccum circuit breaker (VCB) complete all as specified and directed. Note : (i) All the instruments, primary and secondary injection kit and T&P required for the above job shall be arranged by the contractor at site and cost of the same deemed to be included in the quoted rate. (ii) The above checking, inspection, installation and testing work shall be performed by Rep/ Engineer of OEM.
Supply only Current transformer, indoor comprising of 3 Nos single phase resin cast CTs of 100/5 amps ratio, PS class, with suitable VA burden and accuracy suitable for protection & metering of 11 KV VCB panel complete all as specified & directed.
Cleaning of VCB/RMU outer surface suitable for painting VCB (indoor type)/RMU(outdoor),size of VCB/RMU as per available on site including painting of CT's & PT' s and painting complete by spray machine of light grey colour including VCBs accessories etc all as specified and directed.
M&L for MCCB 4 pole 100 amps rating, 16 KA breaking capacity, 415 Volt with thermal & megnatic release safety arrangements, adjustable type, all as specified and directed.
M&L for MCCB 4 pole 125 amps rating, 16 KA breaking capacity 415 volt with thermal & megnatic release safety arrangements,, adjustable type, all as specified and directed.
M&L for MCCB 4 pole 160 amps rating, 36 KA breaking capacity 415 volt with thermal & megnatic release safety arrangements,, adjustable type, all as specified and directed.
M&L for MCCB 4 pole 200 amps rating, 36 KA breaking capacity 415 volt with thermal & megnatic release safety arrangements,, adjustable type, all as specified and directed.
M&L for MCCB 4 pole 250 amps rating, 36 KA breaking capacity 415 volt with thermal & megnatic release safety arrangements,, adjustable type, all as specified and directed.
M&L for MCCB 4 pole 400amps rating, 35/36 KA breaking capacity 415 volt with thermal & megnatic release safety arrangements,, adjustable with microprocessor based type, all as specified and directed.
M&L for checking (All connection and mechanism) cleaning servicing overhauling testing including replacement of minor parts complete of 3 phase 11 KV ring main unit any type/make/model outdoor type respectively, all as directed. (Note - Battery, DC motor will be measured and paid seperately)
Supply only (in-replacement) Maintenance free dry battery of capacity 12 volt 60 AH, for RMU of 630 amp capacity, all as specified and directed.
Supply only (in-replacement), DC operated motor for RMU of 630 amp capacity, all as specified and directed.
M&L for Printed circuit board for RMU scada operation suitable for 630 amp capacity (make: Crompton Greaves/ABB)
M&L for Copper Bus bar of suitable size of capacity 400 Amps for VCB installed at various locations /substations including insulation and fabrication works and necessary connections all as specified and directed
M&L for defect rectification in HT 11 KV cable laid in trenches by locating fault with the help of electronic fault locator machine comprising of surge generator pulse ECHP fault location with high frequency distance calculator etc. Excavation in any type of soil strata exposing the cable fault removal of deteriorated position of cable treating of cable and keeping the same ready for jointing work for cables of size upto 300 sqmm 3 core. The fault located equipment will be brought at site within 02 hours of Instruction received from Engineer-in-charge, complete all as specified and as directed.
Supply, laying & testing Cable jointing kit for 11 KV (Earthed) grade cable for indoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 50 to 95 sqmm 3 core, all as specified and as directed.
Supply, laying & testing Cable jointing kit for 11 KV (Earthed) grade cable for indoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 120 to 185 sqmm 3 core, all as specified and as directed. .
Supply, laying & testing Cable jointing kit for 11 KV (Earthed) grade cable for indoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 240 to 300 sqmm 3 core, all as specified and as directed.
Cable jointing kit for 11 KV (Earthed) grade cable for outdoor, straight through heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 120 sqmm to 185 sqmm, all as specified and as directed.
Supply, laying & testing Cable jointing kit for 11 KV (Earthed) grade cable for straight through heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 95 sqmm 3 core. including excavation, jointing material and accessories complete and cutting of old cable, all as specified and as directed.
Supply, laying & testing Cable jointing kit for 11 KV (Earthed) grade cable for straight through heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 120 to 185 sqmm 3 core. including excavation, jointing material and accessories completeall as specified and as directed.
Supply, laying & testing in replacement of cable XLPE insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) with stranded aluminium conductor, 11000 volts grade, of size 3 core 185 sq mm, all as specified and as directed.
Supply, laying & testing in replacement of cable XLPE insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) with stranded aluminium conductor, 11000 volts grade, of size 3 core 120 sq mm, all as specified and as directed.
Supply, laying & testing in replacement of cable XLPE insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) with stranded aluminium conductor, 11000 volts grade, of size 3 core 95 sq mm, all as specified and as directed.
Supply, laying & testing cable XLPE insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty)with stranded aluminium conductor, 11000 volts grade, of size 95 Sqmm 3 core, complete all as specified and directed. Note:-(i) Excavation, earthwork, cable protection cover, cable joint , sand cushioning shall be measured and paid for saperately under respective item of this schedule. (ii) Quoted rate shall be deemed to include the cost of distrubed surfaces of road , path, hardstanding etc to be made good to conform to the original specifications.
Supply and fixing HT insulating rubber mat of minimum thickness 2.50 mm,all as specified and as directed.,
Supplying & Fixing Caution Plate of size 40cm X 10cm, made out of white acrylic sheet, 3 mm thick, letters “CAUTION : MEN AT WORK" written with Red coloured glow tape complete all as directed
S&F indoor tape insulated ring type BPL low tension current transformers rated burden, 15 VA Accuracy Class 1, 400/5A, all as specified and as directed.
Supply and fixing in replacement of mechanical castle interlock assembly with key suitable for HT 11 KV VCB of rating 630/800 Amps, all as specified and as directed.
Supply and fixing in replacement of panel door lock, all as specified and as directed.
Inspecting, checking (All connections and Mechanism ) cleaning, servicing, overhauling , testing, callibrating the relays (IDMT, over current and earth fault) complete of 11 KV Vaccum circuit breakers indoor type, 630 Amps capacity including following works :- .
(a) Taking out incoming and outgoing HT 11 KV, 3 Core cables from the electric system and and reconnecting the incoming and outgoing HT Cables complete of both panels. (b) All the connections of control wiring availability of proper DC supply and AC supply , incoming and outgoing connections and tightening them , cleaning the contacts and terminal with CRC solution and using the blower for dusting operation, raising and lowering mechanism.
Note :- (i) Servicing, checking and caliberation of VCB shall be carried out by the representative of OEM only using primary and secondary injection kit. (ii) All the test rocord for proper tripping of CTs, raising and lowering operation mechanism and proper tripping system of over current and earth fault relay shall be mentioned and signed by the contractor, Engineer-in-Charge and representative of OEM, shall be submitted before claiming the payment.
Inspecting, checking (All connections and Mechanism ) cleaning, servicing, overhauling , testing, callibrating the relays (IDMT, over current and earth fault) complete of 11 KV Vaccum circuit breakers indoor type, 400 Amps capacity including following works :- .
(a) Taking out incoming and outgoing HT 11 KV, 3 Core cables from the electric system and and reconnecting the incoming and outgoing HT Cables complete of both panels. (b) All the connections of control wiring availability of proper DC supply and AC supply , incoming and outgoing connections and tightening them , cleaning the contacts and terminal with CRC solution and using the blower for dusting operation, raising and lowering mechanism.
Note :- (i) Servicing, checking and caliberation of VCB shall be carried out by the representative of OEM only using primary and secondary injection kit. (ii) All the test rocord for proper tripping of CTs, raising and lowering operation mechanism and proper tripping system of over current and earth fault relay shall be mentioned and signed by the contractor, Engineer-in-Charge and representative of OEM, shall be submitted before claiming the payment. contractor.
Disconnecting HT supply and taking out defective trolley of VCB HT 11 KV, 400/630/800 Amps, any type and servicing of trolley of VCB by cleaning isolating contacts moving parts removing dust particles from bus bar chamber spout gear mechanism and moving parts, repair to motor charge spring mechanism tightening of nut & bolts of entire trolley components all as directed inserting in trolley. testing commissioning and putting on the supply on load complete all as directed. (Note : Spare parts which are required to replace of unserviceable spare parts will be paid separately)
Supply and fixing in replacement of vacuum interrupter of suitable size for HT VCB 630 Amps, all as specified & directed.
Supply and fixing in replacement of vacuum interrupter of suitable size for HT VCB 400 Amps, all as specified & directed.
Supply and fixing in replacement of fixed contact block complete suitable for 630/800 Ampos, 11 KV HT VCB, all as specified & directed.
Supply and fixing in replacement of thermostat suitable for 11 KV HT panel, all as specified & directed.
Supply and fixing in replacement of Closing coil, ISI marked suitable for 11KV VCB Panel, all as specified & directed.
Supply and fixing in replacement of tripping coil, ISI marked suitable for 11KV VCB Panel, all as specified & directed.
Supply and fixing in repair power pack SMPS input 110 Volt AC with PNE 50 Hz and output 110 volt DC with battery complete suitable for 11 KV HT VCB, all as specified & directed.
S & F in replacement of motor & gear assembly 220 volts AC/DC or as per model suitable for 630 Amps HT VCB, all as specified & directed.
S & F in repairs of motor & gear assembly 220 volts AC/DC or as per model suitable for 400Amps HT VCB, all as specified & directed.
S & F in repairs of spout insulator suitable for 630Amps HT VCB of Crompton Greaves make installed in 11 KV HT panel all as specified & directed.
S & F in repairs of spout insulator suitable for 400Amps HT VCB of Crompton Greaves make installed in 11 KV HT panel, all as specified & directed.
Supply and fix in replacement, Main shaft inter lock assembly suitable for HT 11KV/12KV VCB 630 Amps as per existing make and model, all as specified & directed.
Supply and fix in replacement, Big cam with main shaft suitable for HT 11KV/12KV VCB 630 Amps as per existing make and model, all as specified & directed.
Supply and fix in replacement of Big gear assembly suitable for HT 11KV/12KV VCB 630 Amps as per existing make and model, all as specified & directed.
Supply and fix in replacement of Small gear assembly suitable for HT 11KV/12KV VCB 630 Amps as per existing make and model, all as specified & directed.
Supply, installation, testing and commissioning in replacement Current transformer single phase resign cast CTs of 15 VA burden class 1.5 p 10 & PS and ratio 200/100 - 5, all as specified & directed.
Supply, installation, testing and commissioning in replacement PT 11 KV/ 110 Volt suitablefor 11 KV VCB indoor type, all as specified & directed.
Supply and fixing in replacement, moving contact block complete suitable for 630/400 Amps, 11 KV HT VCBs, all as specified & directed.
Supply and fixing in replacement of spring bearing gear for VCB 630/400 Amps, all as specified & directed.
Supply and fixing, set of 06 Nos fixed arcing contacts suitable for 400 Amps, all as specified & directed.
Supply and fixing, set of 06 Nos fixed arcing contacts suitable for 630 Amps, all as specified & directed.
S&F indoor tape insulated ring type BPL low tension current transformers rated burden 5 VA : Accuracy Class 1 100/5A, all as specified & directed.
S&F indoor tape insulated ring type BPL low tension current transformers rated burden 10 VA : Accuracy Class 1 200/5A, all as specified & directed.
S&F indoor tape insulated ring type BPL low tension current transformers rated burden 15 VA : Accuracy Class 1 400/5A, all as specified & directed.
Supply only in replacement of Indicator lamp assembly for RYB phase,all as specified & directed.
Excavation in trenches not exceding 1.5m wide and not exceding 1.5m depth, and and getting out in soft soil/loose, all as specified and directed
Returing filling in including spreading leveling watering and well ramming in layer not exceding 25 cm as in soil all as specified and dirceted.
Removing excavated material to a distance not exceding 50 m and deposting where directed at a level not exceding 1.5 m above the starting point, all as specified and directed
Supply and laying Sand dry as in cushioning of under ground electric cable in trenches, laid to a uniform thickness of 23 cm (15 cm under the cable & 8 cm over the cable) and gently punned down to 18 cm thickness all complete as specified and as directed. (Note - Only punned thickness will be measured for payment purpose).
Supplying and laying un-reinforced precast concrete cable cover, class HV,type 1 with peak, size 300mm x 180mm x 40mm, all as specified and directed
Supplying and laying un-reinforced precast concrete cable cover, class HVP,type 2 with peak, size 450mm x 180mm x 40mm, all as specified and directed
Galvanised iron tubing, 80 mm bore, light grade, laid in trenches/under road/ drains, fixed to poles/walls with required size of flat iron clamps, bolts, nuts and washers complete. (Note:- Earth work shall be measured and paid for separately)
Boring of holes under road, pavement , hard standing by hand method without damaging the surface for 80mm bore GI pipe. (Note:- (i) Depth of hole shall be 1 metre below the top surface of road/pavement/ hard standing. (ii) Pipe shall be measured and paid for separately)
Horizontal boring of holes under road by trenches less technology using ultra sound technology with machine for laying 150 mm bore HDPE pipe without distrubing the road surface, all as specified and directed Note:- (i) Boring shall be done upto 1.20 metre below the top surface of road/pavement/hard standing etc. (ii) Quoted rate deem to be included cost of HDPE pipe 150 mm bore suitable for 0.4 mpa working pressure.
Cable path indicator made of cast iron plate 150 mm dia , 6 mm thick rebated to spot welding with galvanised iron of 35x35x5 mm , 900 mm long embedded in PCC (1:2:4) type B-1 (size 300mm X 300mm X 300mm) including embosing of size of cable HT on CI plate and including earthwork, complete as specified & directed.
R.K.ASSOCIATES
M/S MALHOTRA ENGINEERING WORKS
DEORA ELECTRIC WORKS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .