Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹21.1 LAccepted-AOC 38 30 92 SAI NAGAR MARRIPALEM VISAKHAPATNAM 530 018 | VISAKHAPATANAM | ANDHRA PRADESH | 530018 | L1 | Accepted-AOC Lowest bid | |
| 2 | L2₹22.6 L+₹1.1 L (4.92%)Rejected-Finance FLAT NO 203 SEC 14 PLOT NO 142 SHIVSRUTI PARK APARTMENT E WING 1ST FLOOR MOSHI PRADHIKARAN TAL HAVELI DIST PUNE 412 105 | PUNE | MAHARASHTRA | 412105 | L2 | Rejected-Finance Not a lowest bid | |
| 3 | L3₹23.0 L+₹1.4 L (6.67%)Rejected-Finance | L3 | Rejected-Finance Not a lowest bid | |
| 4 | L4₹23.0 L+₹1.5 L (6.75%)Rejected-Finance PLOT NO 21 KANAKVIHAR KANAKPURA NEAR KANAKPURA RAILWAY STATION JAIPUR 302012 | JAIPUR | JAIPUR | RAJASTHAN | 302012 | L4 | Rejected-Finance Not a lowest bid | |
| 5 | L5₹23.9 L+₹2.3 L (10.8%)Rejected-Finance | L5 | Rejected-Finance Not a lowest bid |
Tender Value
₹35 L
EMD Value
₹70,000
Closing Date
1 Aug 2020, 6:00 pmClosed
GE MH RH KIRKEE
GE MH RH KIRKEE RANGE HILLS ROAD KIRKEE PUNE 411003
REPAIRS AND CLEANING OF MANHOLES SEWAGE LINES SEPTIC TANK AND SOAKAGE WELL ETC AT AUNDH AREA UNDER GE MH AND RH KIRKEE
2020_MES_360284_1
8128/E8
Open Tender
Civil Works
Works
270 days
KIRKEE AND AUNDH
Please refer Tender documents.
6 documents required · 6 mandatory
₹500
GE MH RH KIRKEE
₹70,000
Yes
2 Sept 2020
11 Jul 2020
3 Aug 2020
11 Jul 2020
1 Aug 2020
25 Jul 2020
11 Jul 2020 - 18 Jul 2020
Amount
M&L for Cleaning of all blockage of any type of trap, water closet, soil waste/ vent pipe, gully traps upto first manhole by removing all chockage and removing the same to a distance exceeding 100m and not exceeding 200m and making good the distrurbed surfaces as per existing where required all per directed by Engg-In-Charge
Cleanng of existing 150mm dia sewage line upto 1.00 m depth from ground level using jute or PVC nylon rope with knot at one end and other end free passed through the line or by rodding & removing all liquid/semi solid /solid sludge etc coming in the next manhole is removed and then the line is cleaned with water complete for effectve functioning all as directed by EIC. Note : Quoted rates shall be include working in foul condition.
All as per Item No 02 above but 150 mm dia bore but depth exc. 1.0 m below ground level complete.
All as per Item No 02 above but 200 mm dia bore but depth upto 1.50m below ground level complete.
All as per Item No 02 above but exc. 200 mm dia bore but n.exc 300 mm dia SWG/RCC line and upto a depth of 2.50 m.
Cleaning of existing manholes of any size uptp depth of 1.0 m from top of manholes and removing all semi solid or solid material of any description and cleaning the manholes from inside complete with water etc complete all as directed by EIC. Note : Quoted rates shall be include working in foul condition.
All as per item No 06 above but depth of manholes exceeding 1.0m but n exc 2.5 m.
Cleaning and de-sludging of existing septic tank/ deep manholes upto 3mtr deep including taking out sludge in any form alongwith all other foreign materials by mechanical equipment or manually or by way of any other suitable means including removal of sludge and other foreign materials out side the MD land by any means complete (working in foul condition ) all as specified & directed.
Mechanically pumping out sewage water from sump well where required and as directed with taking precautionary measures including tools and plants as required and removing to a distances exc 50m but not exceeding 100m from the site (working in foul condition) complete all as specified and directed
Excavation in trenches not exceeding 1.50m wide and 1.50m depth for foundation, etc., for Shaft wells, Manholes etc not exceeding 10sqm on plan and not exceeding 1.50m in depth and getting out in soft / loose soil all as specified and directed.
All as per Item No 10 above, but for depth exceeding 1.5m and not exceeding 3.0 m in soft/loose soil.
Returning filling in including spreading leveling watering well ramming in layers not exceeding 25cm thick with soil obtained from excavation all as directed.
Removing excavated surplus soil/rock not exceeding 50m and depositing where directed at a level exceeding 1.5m above the starting point all as directed.
Demolition and breaking up drain pipes of 150 mm bore RCC/SGSW set in cement mortar including removing the debries to a distance n exc 100m,where directed
All as per item No. 14 above but dia of pipe 200mm.
All as per item No. 14 above but dia of pipe 300mm.
M&L for PCC 1:4:8 type D-2 using 40 mm graded stone aggregate as in concrete bed to drain pipes including packing under and haunching against sides of pipes with concrete after they are laid and bedded dia of pipe 150mm all as specified and directed.
All as per item No. 17 above but dia of pipe 200mm.
All as per item No. 17 above but dia of pipe 300mm.
M&L for 150mm dia RCC drain pipes class NP2 laid in trenches and jointed with in cement mortar all as specified.
All as per item No. 20 above but dia of pipe 200mm.
All as per item No. 20 above but dia of pipe 300mm.
M&L cutting to existing manholes for connecting new drain, making good to pipe and rendering, cutting out existing benchings for and forming branch channel (1/2 round or 3/4 section) in cement concrete 1:2:4 type B1, using 20mm graded stone aggregate, smooth finished and reforming benching as required for internal dia of pipe 150mm all as directed.
All as per item No. 23 above but for internal dia of pipe 200mm dia
All as per Item No 24 above but for internal dia of pipe 300mm dia
Demolition of Brick/PCC solid block masonry built in cement mortar/cement lime mortar including removing the debries to a distance n exc 50M all all as specified and directed.
M & L Pre-cast cement concrete type C1 1:3:6 block masonry with solid blocks, exc. 10 cm in width and setting in mortar 1:4, complete all as specified
M&L for rendering 15mm thick in CM 1:4 mixed with water proofing compound as per manufacturer's instructions on block walling / concrete surfaces finished even and smooth without uing extra cement all as directed. Note :- Water proofing compound shall be measured and paid separately.
Supply only integral water proofing compound.
Demolition of concrete of any description below or above ground and in any position not otherwise specifically provided for complete all as directed.
M&L for Cement concrete type B2 1:2:4 (40mm graded stone aggregate) in surface channels and drains all as specified
Extra for forming fair finished drain or channel 30 cm inner girth in cement concrete, using ex- tra cement, including forms, moulds, mi- tred/stopped ends etc. all as specified
M&L for PCC 1:2:4 type B0 using 12.5mm graded stone aggregate as in coping and benching of manholes etc., finished smooth including neceessary form work complete all as specified and directed.
M&L for PCC 1:4:8 Type D-2 using 40mm graded stone aggregate as in foundation all as specified and directed.
Demolition of reinforced cement concrete of any description as in cover slab etc and similar work,including removing the debries to a distance not exc 50m, complete all as specified and directed.
M & L for Pre-Cast RCC 1:2:4 nominal mix, type B1 Using (20mm graded aggregad ) as in cover slabs set in cement mortar 1:4 including necessary formwork all as specified and directed. Note :Reinforcement shall be measured and paid separately .
M&L TMT bars 6 to 8 mm dia bars cut to length, bent to shape required including cranking, bending, hooking ends, and binding with mild steel wire not less than 0.9 mm dia confirming to IS, all as specified and directed.
S&F in repairs 75 mm Cast iron floor trap / Nahani trap, with grating including jointing to waste pipe fixed in cement concrete type B1 1:2:4, using 20mm graded stone aggregate complete all as specified and directed.
S&F in repairs PVC (SWR) gully trap 125/110 mm, setting and jointing with solvent cement all as specified and directed.
S & F in repairs PVC High/Low level flushing cistern 10 litrescapacity including all fittings i.e float valve, syphon, flushpipe,brackets all as specified and directed by EIC.
Taking down drain pipes (any size or pattern), including all fittings, Tee, bends,etc., including cleaning or refixing (measured overall as fixed along the centre line over fitting and accessories)
S&F of PVC (SWR) pipes of 75mm dia single socketed, in any length with rubber ring joints, laid in trenches or in floors/ wall all as specified
S&F of PVC (SWR) pipes of 110mm dia single socketed, in any length with rubber ring joints, laid in trenches or in floors/ wall all as specified
S&F of PVC (SWR) bend of 75mm radius all as specified.
S&F of PVC (SWR) bend of 110mm radius all as specified
S&F of 75mm dia PVC (SWR) branch piece, single (single Y) equal or unequal.
S&F of 110mm dia PVC (SWR) branch piece, single (single Y) equal or unequal all as specified.
M&L for Cement concrete 75mm thick type C- 2, 1:3:6 (40mm graded aggregate) as in floor and paving etc all as specified.
S & F in repairs water closet (Squatting Pattern) complete incl provn of lime concrete bedding Orissa pattern size 580 x 440mm white integral foot rests (excluding flush pipe or flushing cisterns) including connection to trap and flushing pipe anti syphonage pipe etc complete and making good to floor.
S&F in repairs Vitreous China wash down water closet pan (pedestal pattern), white (excluding fixing bolts, flushing cistern and flush pipe) including connection to trap and flushing pipe anti syphonage pipe etc complete and making good to floor.
S&F in repair of vitreous china bowl type urinal flat back size 465 x 355 x 265 mm white with grating and union for discharge including flush pipe complete all as specified and directed.
SKS Electricals
Aishwarya Constructions
M/s ESS KAY Construction
V.R.PRAJAPATI AND CO.
Shri Sant Cosntruction
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .