Tender Value
₹1.7 Cr
EMD Value
₹3.5 L
Closing Date
19 Oct 2026, 11:00 pm
BINDEY KUMAR
DIRECTOR
SHEIKHPURA PATNA
BINDEY KUMAR
DIRECTOR
SITC OF HT Panels, Main LT Panel, LT Cable and Wiring work in New Substation for New RIO Building at IGIMS, Patna
140510
IGIMS / EC/ EW/ 07/ 2026-27
Open Tender
ELECTRICAL
Sheikhpura
• Non-Refundable cost of required B.O.Q. amounting to the respective Column as per NIT.
• Refundable Earnest Money Deposit (EMD)amounting to the respective Column as per NIT.
• c) Notarize copy of experienced firms registered under CPWD, BCD, Energy Department, PESU, Railway or in any government organization under which similar nature of work has been carried.
• Notarize copy Permanent Account Number with annual turn over for last five years.
• Notarize copy of valid GST Certificate with updated challan
• Notarize copy of Valid Electrical Contractor License / Supervisor license of the suitable class in the name of the bidder issued from the competent government licensing authority.
• Notarize copy of similar nature of work carried out by the Contractor in Last 5 Years.
• Notarize copy of Bid capacity
• Notarize copy Details of technical personnel available with contractor
• Notarize copy of List of Tools, Plants and Machineries available with the bidder for use on the respective work for which prospective bidder is submitting the tender.
• Notarize copy of Valid Character certificate issued from Govt. department
• Notarized copy of P.F and E.S.I registration Certificate with updated challan.
• The Bidder should submit original Notarized certificate on Rs.1000.00 non-judicial stamp that it has not been blacklisted, debarred, declared non-performeror expelled by Union Govt./State Govt. / PSU?s during the last 5 years
• The Bidder should submit original Notarized certificate on Rs.1000.00 non-judicial stamp that in case any ambiguity is noticed in the documents submitted at any stage, we shall be entirely responsible and liable for any action as deemed fit under the law" shall be submitted by the Firm/Agency with Technical bid.
• Noratize Copy of Bar Chart.
ELECTRICAL
ITEM RATE
L1
1
15 documents required · 15 mandatory
₹10,000
Processing Fee: 5900
₹3.5 L
24 Sept 2026
24 Sept 2026
22 Oct 2026
25 Sept 2026
19 Oct 2026
25 Sept 2026
TECHNICAL BID SHEET
INDIRA GANDHI INSTITUTE OF MEDICAL SCIENCES, PATNA
E-Tender Notice No: IGIMS / EC/ EW/ --/ 2026-27 Date
Name of Work :- SITC of HT Panels, Main LT panel , LT Cable, And Wiring work in new substation for new RIO Building at IGIMS, Patna
Owner Name :- Indira Gandhi Institute of Medical Science, Patna Period of Bid Validity :- 120 Days E-Tendering fee (in Rs.) :- ===> As per generated by www.eproc2.bihar.gov.in
Estimated Cost ( Rs)===> ₹1,73,22,828.00 (Rupees One Crore Seventy Three LakhTwenty two Thousand Eight hundred Twenty Eight only) EMD Amount (in Rs.) =====> Rs. 3,46,460.00 ( Ruppes Three Lakhs Forty SixThousand , Four Hundred, Sixty Only) Cost of bid Documents Amount (in Rs) =====> Rs.10000.00 (Ruppes TenThousand only)
Time of Completion in months :- 5 Months
Name and address of the bidder
1 Non-Refundable cost of required B.O.Q. amounting to the respective Column as per NIT.
2 Refundable Earnest Money Deposit (EMD)amounting to the respective Column as per NIT.
3 c) Notarize copy of experienced firms registered under CPWD, BCD, Energy Department, PESU, Railway or in any government organization under which similar nature of work has been carried.
4 Notarize copy Permanent Account Number with annual turn over for last five years.
5 Notarize copy of valid GST Certificate with updated challan
6 Notarize copy of Valid Electrical Contractor License / Supervisor license of the suitable class in the name of the bidder issued from the competent government licensing authority.
7 Notarize copy of similar nature of work carried out by the Contractor in Last 5 Years.
8 Notarize copy of Bid capacity
9 Noratize Copy of Bar Chart.
10 Notarize copy Details of technical personnel available with contractor
11 Notarize copy of List of Tools, Plants and Machineries available with the bidder for use on the respective work for which prospective bidder is submitting the tender.
12 Notarize copy of Valid Character certificate issued from Govt. department
13 Notarized copy of P.F and E.S.I registration Certificate with updated challan.
14 The Bidder should submit original Notarized certificate on Rs.1000.00 non-judicial stamp that it has not been blacklisted, debarred, declared non-performeror expelled by Union Govt./State Govt. / PSU’s during the last 5 years
15 The Bidder should submit original Notarized certificate on Rs.1000.00 non-judicial stamp that in case any ambiguity is noticed in the documents submitted at any stage, we shall be entirely responsible and liable for any action as deemed fit under the law" shall be submitted by the Firm/Agency with Technical bid.
Note:- Intending bidders must enclose all required papers as per Technical Bid sheet and Financial Bid Sheet in hard copy also on or before last date of submission of Tender, failing which there tender will be declared non responsive.
Price-Bid (BOQ)
E-Tender Notice No: IGIMS / EC/ EW/ 07/ 26-27
SITC of HT Panels, Main LT panel , LT Cable, And Wiring work in new substation for new RIO Building at IGIMS, Patna
Estimated Cost (In Rs.) ₹1,73,22,828.00 (Rupees One Crore Seventy Three Lakh Twenty Two Thousand Eight hundred Twenty Eight only)
Earnest Money ( in Rs) Rs. 3,46,460.00 ( Ruppes three Lakhs Fourty Six Thousand Four Hundred and Sixty Only)
Cost of B.O.Q. ( In RS) Rs.10000.00 (Ruppes TenThousand only)
E-tendering fee (Non Refundable) As per generated bywww.eproc2.bihar.gov.in
Time of completion ( In Days) 6 Months
Date/ time for obtaining BOQ (Only on www.eproc2.bihar.gov.in) As pe NIT
7 Last date/Time for uploading of complete tenderDocument (on www.eproc2.bihar.gov.in) As per NIT
8 Last date/Time for submission of complete tender Document Hard copy at Director’s Office IGIMS through Regd./speed post/courier. As per NIT
9 Date/Place of opening of Tender (Technical bid only on www.eproc2.bihar.gov.in) As per NIT
Date/Place of Opening of Tender (Price bid only on www.eproc2.bihar.gov.in) Date of opening of Price bid of Technically viable tender shall be intimated only through www.eproc2.bihar.gov.in and on Institute web site www.igims.org
Bidders are requested to quote their minimum % rate above or below or at estimated rate for following Scedule items
Sr.No Schedule Items Unit Qty Rate Total Amount
Group -A, Internal Electrical Works of Substation Building and Earthing works
1 Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable size GI box etc as required.
a) Group -C Each 95 1146
2 Supplying and fixing 2 pin, 6 amp ceiling rose on the existing junction box/ wooden block including connection etc as required. Each 65 64
3 Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required
a) 2 x 2.5 sq.mm. + 1 x 2.5 sq.mm. earth wire Meter 110 246
b) 2 x 4 sq.mm. + 1 x 4 sq.mm. earth wire Meter 165 309
c) 4x10sq.mm+ 1x6 sq. mm.earth wire Meter 90 925
4 Supplying and fixing following way horizontal type three pole and neutral, sheet steel MCB distribution board 415 volts on surface / recess complete with tinned copper bus bar neutral bus bar , earth bar , din bar interconnections , powder painted including earthing etc as required. ( but without MCB/RCCB/Isolator)
a) 8 way (4 + 24), Double door , horizantal type Each 2 6199
5 Supplying and fixing following amps rating, 240/415 volts, “C” curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
a) 6/32 Amps Single Pole Each 48 237
b) 40A to 63 AmpsTriple pole and neutral Each 2 2329
6 Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.
a) 6 Module(200mmx75mm) Each 15 345
7 Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required
a) 5/6 amps switch Each 14 82
b) 15/16 Amps switch Each 25 139
c) 3 pin 5/6 Amps socket outlet Each 14 112
d) 6 pin 15/16 Amps socket outlet Each 25 183
8 Supplying and fixing 4'x18 Watt watt LED batten with minimum efficacy 100 lm/w in polycorbonate housing and complete with integrated electronic driver etc directly on wall /ceiling including connection with 1.5 sq mm FRLS PVC insulated copper conductor etc as required Each 40 521
9 Supply and installation of regulator /standard model A.C ceiling fan of 1200 mm sweep with service value (CM/MM) minimum 4.00 Air delivery minimum 210 cum/min including wiring the down rod of standard length (upto 30 cm)with 1.5 sq mm FRLS PVC insulated copper conductor etc as required Each 10 2482
10 Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate/,switch box including connections but excluding modular plate etc. as required. Each 10 359
11 Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories and providing masonary enclosure with cover plate having locking arraangement and watering pipe etc with charcoal /coke and salt as required Each 5 6323
12 providing and fixing 25 mm x5 mm G. I strip on surface or in recess for connection etc as required meter 105 195
13 Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required. Set 5 12831
14 Providing and fixing 25mmx25mm copper strip on surface or in recess for connection etc as required Meter 95 1032
15 Supply and installation of following sweep/sizes metalic blade ,heavy duty,sigle phase 230 v a.c exhaust fan in the existing opening including making good the dammage connection testing commissioning etc as required.
a) 300 mm sweep Each 1 2572
b) 380 mm sweep Each 10 5560
16 Supplying and fixing following types LED Flood light with minimum efficacy 100 lm/w in die cast aluminium housing, toughened glass, lP 66 protection and complete with electronic driver etc on pole/building including connection earthing the body etc as required.
a) 100 Watt Each 20 6085
b) 200 Watt Each 6 10495
SubTotal Group-A
Group-B (CABLING WORKS , LAYING , CLAMPING, END TERMINATION ETC.)
17 Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required
a) upto 35 sq. mm(clamped with1mm MS flat clamp) Meter 550 43
b) Above 35 sq. mm and upto 95 sq. mm(clamped with25x3mm MS flat clamp) Meter 420 109
c) Above 95 sq. mm and upto 185 sq. mm(clamped with25/40x3mm MS flat clamp) Meter 300 124
d) Above 185 sq. mm and upto 400 sq. mm (clamped with40x3mm MS flat clamp) Meter 350 171
18 Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground in the same trench in one tier horizontal formation including excavation and refilling the trench etc. as required . but excluding sand cushioning and protec tive covering .
a) upto 35 sq. mm Meter 110 160
b) Above 35 sq. mm and upto 95 sq. mm Meter 210 182
c) Above 95 sq. mm and upto 185 sq. mm Meter 250 204
d) Above 185 sq. mm and upto 400 sq. mm Meter 300 270
19 Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on cable tray as required
a) upto 35 sq. mm(clamped with1mm MS flat clamp) Meter 300 53
b) Above 35 sq. mm and upto 95 sq. mm(clamped with25x3mm MS flat clamp) Meter 310 109
c) Above 95 sq. mm and upto 185 sq. mm(clamped with25/40x3mm MS flat clamp) Meter 110 138
d) Above 185 sq. mm and upto 400 sq. mm (clamped with40x3mm MS flat clamp) Meter 350 226
20 Laying of one number XLPE power cable of 33 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required
a) Above 120 sq. mm and upto 400 sq. mm Meter 390 177
21 Trenchless laying of HDPE pipe by using HDD method including laying of cable ( 33 KV & 11 KV ), Digging and refilling of pits etc. inclusive of GST. Meter 850 915
22 HDPE Pipe Meter 850 710
LT cable from substation to RIO Building (Length in lumpsum)
23 Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.
a) 3.5x 25 sq. mm(28 mm) Each 10 371
b) 3.5x 35 sq. mm(32 mm) Each 22 437
c) 3.5x 50 sq. mm(35 mm) Each 28 484
d) 3.5x 70 sq. mm(38 mm) Each 12 542
e) 3.5x 95 sq. mm(45 mm) Each 6 684
f) 3.5x 120 sq. mm(45 mm) Each 8 710
g) 3.5x 150 sq. mm(50 mm) Each 10 798
h) 3.5x 185 sq. mm(57 mm) Each 4 1001
j) 3.5x240 sq. mm(62 mm) Each 18 1160
k) 3.5x300 sq. mm(70 mm) Each 28 1336
l) 3.5x400 sq. mm(70 mm) Each 6 1713
24 Supplying and making indoor cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for following size of 3 core, XLPE aluminium conductor cable of 33 KV grade as required
a) 240 sq. mm Each 5 36120
25 Supplying and making outdoor cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for following size of 3 core, XLPE aluminium conductor cable of 33 KV grade as required
a) 240 sq. mm Each 2 75301
26 Supplying and making straight through cable jointing with heat shrinkable jointing kit complete with all accessories including ferrules suitable for following size of 3 core, XLPE aluminium conductor cable of 33 KV grade as required
a) 240 sq. mm Each 2 103493
Sub-Total Group-B
Group-D (HT Panel, LT Panel, Capacitor Panel etc.)
27 33 kv VCB Panel
Supply of HT Panel Set having Incomer and Outgoing, Indoor Type, Metal Clad Floor Mounted of 33 KV, incorporating Vacuum Circuit Breaker, Panels along with remote control & equipped with all specified accessories i.e. CTs, PTs (Indoor Type), metering and protection system including termination etc. Power frequency withstand voltage: 70 KV rms for 60 sec, Rated lightning impulse withstand voltage (peak):1.2/50 micro sec: 170 KV, Rated short circuit breaking current (rms): 25 KA for 3sec., Rated short circuit making current (peak): 78.75 KA. Circuit breaker shall be mounted on a withdrawable truck which shall be horizontally draw out from service position to isolated position i.e. “Complete Roll on floor type of design”. Cassette type VCB design is not acceptable. Switchgear shall be fully type tested for extended mechanical endurance of M2 class as per IEC 62271. Half Moulded SMC 31.5 % Glass housing between phases should be provided. Bakelite, Lamtuf sheet or any other phase separation sheet is not acceptable between phases. It should be possible to open/close the door of the VCB compartment in a single latch action. A special provision should be provided so that rear door cover should be interlocked with same panel front door. Make: OEM or their Licensee partner complying with the specifications. Type test certificate issued by CPRI/ ERDA or any other NABL accredited agency. Set 1
Each incomer VCB should be as below.
BREAKER: 33kV, 1250A, 25 kA, 110V DC TC CC, 230V AC motor spring charged mechanism type Vacuum Circuit breaker. Acceptable 2
CURRENT TRANSFORMER: 100-50/1-1A, Acc. Class – 0.5, 5P10. Acceptable 6
POTENTIAL TRANSFORMER: Ratio: 33KV/v3/110V/v3 Volts, Accuracy class is 1.0 Rated Burden 50VA. Acceptable 1
Meters: MFM of Accuracy class 1.0 monitoring all electrical parameters like per phase, V, In, Ay, Ar, Ab, demand, W, VA, VAR, all instantaneous, integrated and demand parameters, Neutral current, Frequency, PF, % load, with MODBUS protocol. 2
Digital Ammeter with Selector switch Acceptable 2
Digital Voltmeter with Selector switch Acceptable 2
RELAYS: The offered relays shall be multifunction numerical type. All Numerical relays Relay shall have minimum following features: Relay shall be suitable for 1A CT secondary. Relay shall be provided with rear RS485 port for connection to remote operation. Relay setting change. Reading the measurement values. Relay shall be provided with an alpha numeric LCD display and keypad for navigation and setting. 2
Microprocessor based numerical relay (IDMT relay) with 2 levels of over current and earth fault protection, 3 O/C and 2 E/F element with LED’s for fault indication and at least 15 trip records for over current & 15 for earth fault. Trip records must be with date & time stamping. FDR 22 model only. 2
Anti Pumping device. 2
Trip circuit supervision relay 2
High speed master trip relay 2
Transformer Supervision Relays 2
Annunciator (8 Window) for Transformer feeder 2
Phase sequence Indication arrangement to be provided. 2
Amber for Trip indication. 2
Red 'ON' Green 'OFF' Spring charge indication. Trip Circuit Healthy indication. 8
Breaker positioning lamps & DC Circuit Healthy indicaton lamp. 4
Accessories like local remote selector switch, TNC switch, Space heater with thermostat – 2 nos., DC & AC control circuit through MCB, Indicating LED lamps, Spring Charged indication, DC supply healthy, Breaker ON/OFF, in service, test, disconnected position etc. should be provided.
Hooter with Accept/Reset & Test Push Button 1
Local/remote Selector Switch & Emergency Push Button with necessary NO/NC Contacts.
Power Pack Unit for providing auxiliary power to Trip Coil and other necessary equipments as required. 1
Provision for installation of meter from electricity board
Out going: 2 nos
Each Outgoing VCB should be as below.
BREAKER: 33kV, 800A, 25 kA, 110V DC, 230V AC motor spring charged mechanism type Vacuum Circuit breaker. 2
Meters: Multi-function meter (MFM) of Accuracy class 1.0 as per IEC 62052-33/IEC 62053-22 monitoring all electrical parameters like per phase, V, In, Ay, Ar, Ab, demand, W, VA, VAR, all instantaneous, integrated and demand parameters, Neutral current, Frequency, PF, % load, working on MODBUS protocol. Acceptable make: Lauritz Knudsen 4400 series 2
Digital Ammeter with Selector switch Acceptable 2
RELAYS: The offered relays shall be multifunction numerical type. All Numerical relays Relay shall have minimum following features: Relay shall be suitable for 1A CT secondary. Relay shall be provided with rear RS485 port for connection to remote operation. Relay setting change. Reading the measurement values. Relay shall be provided with an alpha numeric LCD display and keypad for navigation and setting.
Microprocessor based numerical relay (IDMT relay) with 2 levels of over current and earth fault protection, 3 O/C and 2 E/F element with LED’s for fault indication and at least 15 trip records for over current & 15 for earth fault. Trip records must be with date & time stamping. FDR 22 Only. 2
Anti Pumping device. 2
Trip circuit supervision relay 2
High speed master trip relay 2
Sensitive Earth Fault Relay 2
Annunciator (8 Window) for Transformer feeder 2
Phase sequence Indication arrangement to be provided.
Amber for Trip indication.
Red 'ON' Green 'OFF' Spring charge indication. Trip Circuit Healthy indication.
Breaker positioning lamps & DC Circuit Healthy indicaton lamp.
Accessories like local remote selector switch, TNC switch, Space heater with thermostat – 2 nos., DC & AC control circuit through MCB, Indicating LED lamps, Spring Charged indication, DC supply healthy, Breaker ON/OFF, in service, test, disconnected position etc. should be provided.
BUS BAR: 1250 A TP AL Bus Bar
it shall be single bus bar pattern with air insulated encapsulated bus bars housed in a separate compartment, segregated from other compartments. The Bus bar material shall be high conductivity Alumunium rated as specified. Max. Bus Bar temp shall not exceed 90 degree C in any conditions viz. rated and short circuit current.
Short time current rating : 31.5 kA Duration of Short circuit withstand : 3 Sec
Short time current rating : 31.5 kA Duration of Short circuit withstand : 3 Sec
28 Main LT Panel
Supply of indoor LT Panel IP 42, type tested from ASTA/CPRI/ERDA as per IEC 61439 Part 1 & 2, internal arc compliance of 70kA-0.5s as per IEC 61641, IK10 as specified in IEC 62262, ICC ES AC -156, 3.2g Compliance. The LV Panel shall be manufactured in accordance with switchgear OEM design guidelines, ensuring full compliance with IEC 61439 standards. The type test certification shall be done by OEM and franchisee shall carry out assembly as per type tested design. To ensure compatibility, both the panel design and the switchgear components (ACB/MCCB/Control gear etc) should be from same OEM. The type designation and certification label on the panel shall prominently feature the OEM's name. Set 1
TRANSFORMER INCOMER-1
3200 4P 65kA EDO ACB with microprocessor release having LSING protection with RS485, Pollution degree 4. It should have Combined Test Sequence Certification from CPRI/ERDA/ASTA. It should have arc chute interlocking, Mechanical & Electrical anti-pumping. The release shall have current metering & oLED display of Current, % Loading, last 20 trip data, ZSI, Seperate LED for Pwr, O/L, S/C, INST, E/F, NTRL, ALRM, TRIP. 1
Under Voltage with time delay Release for ACB 1
Shunt Release for ACB 1
Mechanical Interlock using Key & Lock 1
Locking arrangement for OFF button with R - Lock (on breaker) 1
multifuction meter with basic parameters like frequency, V, In, Ay, Ar, Ab, KW, KVA, KVAR, Power Factor, total harmonic distortion etc. shall be suitable for EMS function with RS 485 port for communication. 1
Breaker Control Switch (TNC) 1
CTs - 3200/5A , 15VA , Class -1 Tape Wound for Metering 3
3200/5A 15VA CL1 CT FOR ASVG panel 3
AUX CONTACTOR 2NO+2NC 3
220V AC Indication LED Type (R/Y/B Phase On) 3
240V AC Indication LED Type ( Breaker On/Off) 2
6A DP MCB, 10kA, C-Curve 2
SP MCB, 10kA, C-Curve 5
CT Shorting Link 3
Bus Coupler- 2 Nos
3200 4P 65kA EDO ACB with microprocessor release having LSING protection with RS485, Pollution degree 4. It should have Combined Test Sequence Certification from CPRI/ERDA/ASTA. It should have arc chute interlocking, Mechanical & Electrical anti-pumping. The release shall have current metering & oLED display of Current, % Loading, last 20 trip data, ZSI, Seperate LED for Pwr, O/L, S/C, INST, E/F, NTRL, ALRM, TRIP. 2
Under Voltage with time delay Release for ACB 4
Mechanical Interlock using Key & Lock 8
Locking arrangement for OFF button with R - Lock (on breaker) 8
On delay timer 2
Breaker Control Switch (TNC) 2
AUX CONTACTOR 2NO+2NC 4
220V AC Indication LED Type (R/Y/B Phase On) 6
240V AC Indication LED Type ( Breaker On/Off) 6
6A 4P 10KA MCB FOR SECONDARY PROTECTION OF PT 6
6A DP MCB, 10kA, C-Curve 6
SP MCB, 10kA, C-Curve 10
DG INCOMER - From Sync Panel
3200 4P 65kA EDO ACB with microprocessor release having LSING protection with RS485, Pollution degree 4. It should have Combined Test Sequence Certification from CPRI/ERDA/ASTA. It should have arc chute interlocking, Mechanical & Electrical anti-pumping. The release shall have current metering & oLED display of Current, % Loading, last 20 trip data, ZSI, Seperate LED for Pwr, O/L, S/C, INST, E/F, NTRL, ALRM, TRIP. 1
Under Voltage with time delay Release for ACB 1
Shunt Release for ACB 1
Mechanical Interlock using Key & Lock 1
Locking arrangement for OFF button with R - Lock (on breaker) 1
multifuction meter with basic parameters like frequency, V, In, Ay, Ar, Ab, KW, KVA, KVAR, Power Factor, total harmonic distortion etc. shall be suitable for EMS function with RS 485 port for communication. 1
Breaker Control Switch (TNC) 1
CTs - 3200/5A , 15VA , Class -1 Tape Wound for Metering 3
CT 3200/5A 15VA CL1 CT for Sync Relay 4
AUX CONTACTOR 2NO+2NC 3
220V AC Indication LED Type (R/Y/B Phase On) 3
240V AC Indication LED Type ( Breaker On/Off) 3
6A DP MCB, 10kA, C-Curve 4
SP MCB, 10kA, C-Curve 4
CT Shorting Link 3
Digital Voltmeter - 3 Phase 1
Auto/manual Selector Switch 1
Phase Sequence Relay 1
SYNCHRONOUS RELAY 1
BATTERY CHARGER WITHOUT BATTERY 1
12 POINT ANNANCIATOR 1
ELECTRONIC HOOTER 1
EMERGENCY STOP PUSH BUTTON 1
Electrical Interlocking arrangement for Main ACBs & Buscoupler ACBs 1
Bus Bar - 3200A, TPN electrolytic grade AL bus bar, 50 kA for 1 sec with current density of 130A/Sq CM
OUTGOING 630A MCCB FEEDER 2
MCCB 630 A, 4P, Ics=100% of Icu=36 kA,having TM release with double break Contact Locking Dead-Centre (D/C) mechanism, adjustable overload setting of 0.67-1 x Ir, Variable S/C 1.5-8 x In. MCCB shall have true rms sensing, no Load-line bias, double insulation, inbuilt ambient temperature compensation. 2
EXTENDED ROTARY HANDLE for 630A MCCB 2
630A 4P SPREADER LINK 2
MCCB AUX CONTACT 2
multifuction meter with basic parameters like frequency, V, In, Ay, Ar, Ab, KW, KVA, KVAR, Power Factor, total harmonic distortion etc. shall be suitable for EMS function with RS 485 port for communication. 2
630/5A 15VA CL1 CT 6
Indicating Lamp - R/Y/G/On/Off 10
6A SP 10KA MCB 10
OUTGOING 500A MCCB FEEDER 4
MCCB 500 A, 4P, Ics=100% of Icu=36 kA,having TM release with double break Contact Locking Dead-Centre (D/C) mechanism, adjustable overload setting of 0.67-1 x Ir, Variable S/C 1.5-8 x In. MCCB shall have true rms sensing, no Load-line bias, double insulation, inbuilt ambient temperature compensation. 4
EXTENDED ROTARY HANDLE for 400A MCCB 4
500 4P SPREADER LINK 4
MCCB AUX CONTACT 4
multifuction meter with basic parameters like frequency, V, In, Ay, Ar, Ab, KW, KVA, KVAR, Power Factor, total harmonic distortion etc. shall be suitable for EMS function with RS 485 port for communication. 4
400/5A 15VA CL1 CT 12
Indicating Lamp - R/Y/G/On/Off 20
6A SP 10KA MCB 20
OUTGOING 400A MCCB FEEDER 6
MCCB 400 A, 4P, Ics=100% of Icu=36 kA,having TM release with double break Contact Locking Dead-Centre (D/C) mechanism, adjustable overload setting of 0.67-1 x Ir, Variable S/C 1.5-8 x In. MCCB shall have true rms sensing, no Load-line bias, double insulation, inbuilt ambient temperature compensation. 6
EXTENDED ROTARY HANDLE for 400A MCCB 6
400 4P SPREADER LINK 6
MCCB AUX CONTACT 6
multifuction meter with basic parameters like frequency, V, In, Ay, Ar, Ab, KW, KVA, KVAR, Power Factor, total harmonic distortion etc. shall be suitable for EMS function with RS 485 port for communication. 6
400/5A 15VA CL1 CT 18
Indicating Lamp - R/Y/G/On/Off 30
6A SP 10KA MCB 30
OUTGOING 320A MCCB FEEDER 4
MCCB 320 A, 4P, Ics=100% of Icu=36 kA,having TM release with double break Contact Locking Dead-Centre (D/C) mechanism, adjustable overload setting of 0.67-1 x Ir, Variable S/C 1.5-8 x In. MCCB shall have true rms sensing, no Load-line bias, double insulation, inbuilt ambient temperature compensation. 4
EXTENDED ROTARY HANDLE for 400A MCCB 4
320 4P SPREADER LINK 4
MCCB AUX CONTACT 4
multifuction meter with basic parameters like frequency, V, In, Ay, Ar, Ab, KW, KVA, KVAR, Power Factor, total harmonic distortion etc. shall be suitable for EMS function with RS 485 port for communication. 4
320/5A 15VA CL1 CT 12
Indicating Lamp - R/Y/G/On/Off 20
6A SP 10KA MCB 20
OUTGOING 250A MCCB FEEDER 2
MCCB 250 A, 4P, Ics=100% of Icu=36 kA,having TM release with double break Contact Locking Dead-Centre (D/C) mechanism, adjustable overload setting of 0.67-1 x Ir, Variable S/C 1.5-8 x In. MCCB shall have true rms sensing, no Load-line bias, double insulation, inbuilt ambient temperature compensation. 2
EXTENDED ROTARY HANDLE for 250A MCCB 2
250A 4P SPREADER LINK 2
Indicating Lamp - R/Y/G/On/Off 10
6A SP 10KA MCB 10
All the MCB shall have inbuilt mechanical shortcircuit flag indication. MCB Feeder having following rating in a single compartment
Sub-Total Group-D
d) 2C x 4 Sqmm CU armoured Control Cable. Each 4 0
29 Supply of 16 core, 2.5 sq. mm & Balance Stranded Copper, XLPE Insulated, Cores Laid Up, PVC Innersheathed,Armoured, Extruded PVC Type ST2 Sheathed, 650 V/1100 V Grade electric cable with Copper conductor Meter 90
Total Non-Schedule Amount
Total ( Schedule + Non Schedule ) Amount
% High below on SI
Name of the Bidder
Address of the Bidder
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
DocScanner 23 Sept 2026 4-50 pm.pdf
NIT • 4.00 MB
Technical Bid(2).xlsx
NIT • 0.01 MB
Price Bid (7).xls
NIT • 0.08 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .