| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹38.7 LAccepted-AOC | L1 | Accepted-AOC Lowest Bid | |
| 2 | L2₹39.6 L+₹60,841.38 (1.56%)Rejected-Finance SECUNDERABAD | WARANGAL | TELANGANA | 506350 | L2 | Rejected-Finance Being Not Lowest | |
| 3 | L3₹39.7 L+₹71,245.66 (1.83%)Rejected-Finance | L3 | Rejected-Finance Being Not Lowest | |
| 4 | L4₹39.9 L+₹89,789.49 (2.30%)Rejected-Finance | L4 | Rejected-Finance Being Not Lowest | |
| 5 | L5₹41.4 L+₹2.4 L (6.28%)Rejected-Finance | L5 | Rejected-Finance Being Not Lowest |
Tender Value
Refer Docs
EMD Value
₹92,000
Closing Date
7 Aug 2021, 6:00 pmClosed
GE MCEME SECUNDERABAD
GE MCEME Secunderabad MCEME Campus, Trimulgherry (Post) Secunderabad - 500 015
SPECIAL REPAIRS TO CARPENTER SHOP BUILDING NO T 106 OF FEME AT MCEME UNDER GE MCEME SECUNDERABAD
2021_MES_459357_1
GE/MCEME/TOK-22 OF 21-22
Open Tender
Civil Works
Item Rate
180 days
SECUNDERABAD
Class D Category a(I)
8 documents required · 8 mandatory
₹500
GE MCEME Secunderabad
₹92,000
Yes
13 Sept 2021
13 Jul 2021
9 Aug 2021
13 Jul 2021
7 Aug 2021
26 Jul 2021
Amount
Dismantling Single layer Mangalore pattern or similar tiles in roofing, complete all as specified and directed by Engineer-in-Charge.
S & F Pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws, complete all as specified and directed by Engineer-in-Charge.
S & F Pre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed by Engineer-in-Charge.
S & F 0.63 mm thick Plain, galvanised, mild steel sheeting, in ridges, valley gutters, drip and straight flashings (length and girth as fixed) with grade of zinc coating 275, complete all as specified and directed by Engineer-in-Charge.
S&F for Polycarbonate transperant corrugated sheeting 3 mm thick with two corrugations side lap fixed with coach screw and washer in roof, wall etc. complete all as specified and directed by Engineer-in-Charge.
M&L Running welding, thickness of metal to be welded n exc 6 mm, complete all as specified and directed by Engineer-in-Charge.
Dismantling unframed work timber under 40 sq. cm in section , in any position, in fillets, rails, posts, rafters, purlins, etc. , complete all as specified and directed by Engineer-in-Charge.
S&F Rolled mild steel sections as in main & cross beams, hip & jack rafters; purlins where connected to common rafters & running rails & guides for sliding doors; fixed with angle cleats or other connecting plates, Fe410-W (Gde-E-250) quality-A, complete all as specified and directed by Engineer-in-Charge.
Dismantling of wrought iron or mild steel work of any description and in any position not otherwise provided for, complete all as specified and directed by Engineer-in-Charge.
S& F Framed work such as grills, gratings, etc. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe.290.Gde-E-165,etc complete all as per specified and directed by Engr-in-Charge.
S& F Bands, straps, supports or stays for rainwater, ventilating pipes, including bolts, if required:hooks (stay), heavy, for large gates; hook and pintle hinges: large hasps and staples; chains; hand made sliding bolts; clamps; hold fasts; wall ties; hooks for hanging fans; plain angle cleats for securing purlins to wood trusses or rafters; knee piece inserts; two way and three way straps, plate washers and similar small articles conforming to Fe-290 Gde-E-165, etc complete all as specified and directed by Engineer-in-Charge.
M & L Preparation of new or previously untreated steel surfaces of any description, over 10 cm in width or girth and applying two coats of synthetic enamel paint over a coat of red oxide, zinc chrome primer, complete all as specified and directed by Engineer-in-Charge.
M & L Preparation of old painted steel surfaces of any description over 10 cm in width or girth andapplying one coat of synthetic enamel paint, complete all as specified and directed by Engineer-in-Charge.
M&L preparing surfaces of wood and wood based materials, new or old, of any description and girth, not otherwise described and treated with creosote, etc complete all as specified and directed by Engineer-in-Charge.
Demolition of cement concrete (unreinforced) of any description and in any position not otherwise specifically provided for, etc complete all as specified and directed by Engineer-in-Charge.
M&L PCC 1:2:4 type B1 (using 20 mm graded stone aggregate) as in coping, including form work, complete all as specified and directed by Engineer-in-Charge.
Demolition of Brickwork or stone/boulder masonry, built in cement mortar including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stonework and precast concrete articles etc complete all as specified and directed by Engineer-in-Charge.
M&L brickwork with flyash modular bricks, straight or curved on plan exc 6m mean radius, built in CM (1:6), complete all as specified and directed by Engineer-in-Charge.
M & L brick work with flyash modular bricks in cement mortar 1:6 , straight or curved on plan to any radius in half brick thick walls complete all as specified and directed by Engineer-in-Charge.
Taking down of cement plaster on brick or stone walls,/ceiling etc. including raking out joints, hacking for key, scrubbing down with water, etc., complete all as specified and directed by Engineer-in-Charge.
M&L Rendering 10mm thick in CM 1:6 on fair faces of brick work or concrete surface on wall, finished even and smooth (without using extra cement), complete all as specified and directed by Engineer-in-Charge.
Cutting grooves in brick wall, 75mm wide and 65 mm deep and shaping horizontal face of groove with cement mortar 1:3 complete all as specified and directed by Engineer-in-Charge.
M&L Rendering 15mm thick in two layers, 5mm thick in CM 1:4 over 10mm thick in CM 1:6 on brick work or concrete surface on wall, finished even and smooth (without using extra cement) with water proofing compound, complete all as specified and directed by Engineer-in-Charge.
M&L Rough cast plaster as specified ,etc complete all as specified and directed by Engineer-in-Charge.
M&L for applying two coats of OBD over two coats of wall care putty over a coat of alkali resistant primer on wall including preparing the new plastered wall surfaces complete all as specified and directed by Engineer-in-Charge.
M&L for preparation newly plastered surfaces of walls and applying two coat of cement base paint over a coat of alkali resistant primer complete all as specified and directed by Engineer-in-Charge.
M&L for prepration old surfaces of walls and apply one coat of cement base paint, complete all as specified and directed by Engineer-in-Charge.
M&L for Complete removal of existing treatment of wall surface and applying two coats of OBD over a coat of 3mm thick wall care putty complete all as specified and directed by Engineer-in-Charge.
Supply only Integral water proofing compound complete all as specified and directed by Engineer-in-Charge.
M & L for Roughening surfaces of old concrete floor by picking, sweeping clean and washing down with water to remove dust, etc complete all as specified and directed by Engineer-in-Charge.
M&L PCC 1:4:8 type D2 (using 40mm graded agg) as in foundation filling and mass concrete etc complete all as specified and directed by Engineer-in-Charge.
M&L 25mm average thick cement concrete 1:2:4 type B1 using 20mm graded stone aggregate as in floors, etc finished even complete all as specified and directed by Engineer-in-Charge.
M&L for screed bed or bedding layers of cement mortar 1:6, 15 mm thick for laying floor finishes complete all as specified and directed by Engineer-in-Charge.
M & L for machine cut kota stone slab flooring 20-25mm thick over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing etc complete all as specified and directed by Engineer-in-Charge.
M & L for Kota stone slab 20-25mm thick in riser of steps, skirting, dado and pillar laid over cement screed and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing etc complete all as specified and directed by Engineer-in-Charge.
M&L for rendering 10mm thick in cement mortar 1:3 finished rough to receive wall tiles / kota stone etc, complete all as specified and directed by Engineer-in-Charge.
M & L for white tiles, Non - skid Ceramic tiles 7 to 8 mm thick area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match etc complete all as specified and directed by Engineer-in-Charge.
Taking down chowkhats of frames with shutter without taking taking off shutters from the frames exc 1.5 sqm but n.exc 4 sqm, complete all as specified and directed by Engineer-in-Charge.
S&F prepainted steel sliding windows 2 Panel & 2 track sliding window fabricated from roll formed sections made of galvanised steel colour coated/powder coated (base steel as per IS 513 'D' quality, galvanised as per IS 277 with zinc of 120 GM/Sq.mtr) with total coated thickness of 0.58mm. Primer coat with epoxy primer of 5-7 microns thick, finish painted with a polyester paint of 12-16 microns thick and back coated with Alkyd backer of 5-7 microns or powder coated with pure polyester powder upto 50-60 microns thick. Section for external frame should be of 45 x 95mm. Section for glass shutter should be 36 x 50mm. Section for euro groove should be 25 x 24mm and Lap Strip should be of 21 x 4mm (Aluminium) and Touch lock for window. Section for external frame of fixed part should be of 60 x 37mm. Section for mullion of fixed part should be of 48 x 50mm. Section for fixed part beading should be of 12 x 12mm. The window should be panelled with 5mm thick plain float glass. Corner bracket for internal and external frame made of glass filled nylon. Gaskets are to be made of Ethyl Propylene Diamine Monomer (EPDM). The sections are to be cut to length, joined and assembled by means of corner bracket. The above frames should be fixed to the concrete/masonry walls by means of self expanding brackets & screws including 10mm square guard bars with 4" pitch complete all as specified and directed by Engineer-in-Charge. Make :- NCL or equivalent.
Excavating over areas, n exc 1.5m deep and getting out in hard/dense soil complete all as specified and directed by Engineer-in-Charge.
M&L for plain cement concrete 1:4:8 type D2 using 40mm graded aggregate as in surface channel or drain, complete all as specified and directed by Engineer-in-Charge.
M&L cement type C2 1:3:6, using 40mm aggregate in surface channel and drains etc. complete all as specified and directed by Engineer-in-Charge.
M&L for PCC 1:2:4 type B1 (Using 20mm graded stone aggregate) as in precast RCC manhole covers including all form work and set in cm 1:4 complete all as specified and directed by Engineer-in-Charge.(Reinforcement shall be paid extra)
M & L for Mild steel bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips, TMT bars,etc complete all as specified and directed by Engineer-in-Charge.
Returning, filling in, including spreading, levelling, watering and well ramming, in hard / dense soil, in layers not exc 25 cm., complete all as specified and directed by Engineer-in-Charge.
Removing excavated material n exc. 50m and depositing where directed at a level n exc. 1.5m above the starting point in soils, complete all as specified and directed by Engineer-in-Charge.
Surface excavation n.exc 30cm deep and averaging 15cm deep and getting out in hard/ dense soil, complete all as specified and directed by Engineer-in-Charge.
M&L for 100mm thick PCC 1:4:8 type D2 using 40mm graded stone aggregate as in sub base etc., complete all as specified and directed by Engineer-in-Charge.
M&L for Providing and laying 60mm thick factory made chamfered edge cement concrete paver block of M-35 grade with approved colour, design & pattern as in footparth, parks, lawns, drive ways or light traffic parking etc., of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over and including 50mm thick compacted bed of fine sand, compacting and proper embedding/ laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand; complete all as specified and directed by Engineer-in-Charge.
M&L for providing and laying at or near ground level factory made kerb stone of M-25 grade cement concrete in position to the required line, level and curvature, jointed with cement mortar 1:3 (1 cement: 3 coarse sand), including making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5 mm), including making drainage opening wherever required complete all as specified and directed by Engineer-in-Charge.
M&L for sand cushion / sand filling under floors or in foundations including watering and consolidation complete all as specified and directed by Engineer-in-Charge.
Taking down existing unserviceable point wiring of any description/type/ size of light/fan/tube/power/two way/bell etc on TW batten/conduit including removal of batten / conduit / gutties / wooden boards / Hylam sheet/ light fittings etc and removal of unserviceable material out of site and making good the disturbed surfaces of wall/ceiling so as to match with the existing finishes complete all as specified and directed by Engineer-in-Charge.
Material and labour for concealed point wiring with single core PVC insulated unsheathed 1100 volt grade cable with multistranded copper conductor of size 1.5 Sq mm (Nominal area) drawn through and including non metallic rigid PVC conduit medium duty ISI marked of suitable dia conduit concealed wiring including Tee, Junction boxes and provision of 2.0mm thick MS terminal boxes duly painted with red oxide metal primer and covered with 3 mm thick sheet cover of suitable size including suitable screws with washer for mounting switch sockets and regulators and drawing continuous earth wire with and including PVC insulated unsheathed 1100 Volts grade cable with multi stranded copper conductor of size 1.5 Sq mm (Nominal area) and connected to common earth dolly including cutting and chassing of wall complete all as specified & as directed for One light point controlled by one, one way switch 5 amps, SP complete all as specified and directed by Engineer-in-Charge.
All as per item No. 53 above but for One 3 pin 5 Amps switch socket outlet point controlled by one switch on independent board .
All as per item No. 53 above but for One 3 point 5 Amps switch socket outlet point controlled by one switch on the same board.
All as per item No. 53 above but using 4.0 Sqmm single core copper conductor cable multistranded PVC insulated unsheathed 1100 volts grade for 3 pin 15 Amps switch socket combination point including running 4.0 Sqmm copper conductor PVC wire as earth continuity conductor on independant board complete all as specified and directed by Engineer-in-Charge.
Supply and fixing of Switch piano , single pole one way, flush type 5 Amps capacity 230 volts complete all as specified and directed by Engineer-in-Charge.
Supply and fixing of socket outlet 2 in 1 multipurpose 2/3 pin 5 amps flush type complete all as specified and directed by Engineer-in-Charge.
Supply and fixing of switch socket combination 2 in 1 multipurpose 2/3 pin 5 amps flush type complete all as specified and directed by Engineer-in-Charge.
Supply and fixing switch socket combination 2 in 1 multipurpose 3 pin 5/15 amps flush type complete all as specified and directed by Engineer-in-Charge.
Supply and fixing of ceiling rose three terminal surface bakelite type AC 50 Hz 230 Volts complete all as specified and directed by Engineer-in-Charge.
Supply and fix sheet metal enclosure with double pole and Earth Metal Plug & Socket including 20A DP MCB C Series ccomplete all as specified and directed by Engineer-in-Charge.
Supply and fix sheet metal enclosure with triple pole and Earth Metal Plug & Socket including 32A TP MCB C series complete all as specified and directed by Engineer-in-Charge.
Material and labour for concealed Submain wiring with 2 runs of single core 2.5 sqmm PVC insulated unsheathed multistranded 1100 volts grade with copper conductor drawn through and including non-metalic rigid PVC conduit and conduit accessories of medium grade not less than 25 mm dia including one run of single core 2.5sqmm PVC insulated unsheathed multistranded 1100 volts grade with copper conductor cable as earth continuty conductor along with the wiring and connected from DB to DB/main board including cutting and chassing & removing the existing unserviceable sub main wiring and making good the disturbed surface to match with the existing all as specified and as directed.Note:-Two runs of cable, one run of earth contuinity conductor and one run of conduit shall be measured as one unit length. (For Midbay lights)
Material and labour for concealed Submain wiring with 2 runs of single core 10 sqmm PVC insulated unsheathed multistranded 1100 volts grade with copper conductor drawn through and including non-metalic rigid PVC conduit and conduit accessories of medium grade not less than 25 mm dia including one run of single core 10 sqmm PVC insulated unsheathed multistranded 1100 volts grade with copper conductor cable as earth continuty conductor along with the wiring and connected from DB to DB/main board including cutting and chassing & removing the existing unserviceable sub main wiring and making good the disturbed surface to match with the existing all as specified and as directed.Note:-Two runs of cable, one run of earth contuinity conductor and one run of conduit shall be measured as one unit length. (From TPN DB to SPN DB and For single phase Industrial sockets)
Material and labour for concealed Submain wiring with 4 runs of single core 10 sqmm PVC insulated unsheathed multistranded 1100 volts grade with copper conductor drawn through and including non-metalic rigid PVC conduit and conduit accessories of medium grade not less than 32 mm dia including 2 runs of single core 10 sqmm PVC insulated unsheathed multistranded 1100 volts grade with copper conductor cable as earth continuty conductor along with the wiring and connected from DB to DB/main board including cutting and chassing removing the existing unserviceable sub main wiring and making good the disturbed surface to match with the existing all as specified and as directed.Note:-FOUR runs of cable, TWO run of earth contuinity conductor and one run of conduit shall be measured as one unit length. (From MCCB DB to TPN DB)
Material and labour for concealed Submain wiring with 4 runs of single core 6 sqmm PVC insulated unsheathed multistranded 1100 volts grade with copper conductor drawn through and including non-metalic rigid PVC conduit and conduit accessories of medium grade not less than 32 mm dia including 2 runs of single core 6 sqmm PVC insulated unsheathed multistranded 1100 volts grade with copper conductor cable as earth continuty conductor along with the wiring and connected from DB to DB/main board including cutting and chassing and removing the existing unserviceable sub main wiring and making good the disturbed surface to match with the existing all as specified and as directed.Note:-FOUR runs of cable, TWO run of earth contuinity conductor and one run of conduit shall be measured as one unit length. (For 3 phase Industrial sockets)
Supply and fixing LED lights fitting 4ft 1x 20W, 220V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and directed . Make: Havells/Crompton/Bajaj
Supply and fix LED energy efficient building security light fitting of capacity of 35 W for fixing in GI pipe bracket on wall all as specified and directed. NOTE : GI bracket, clamp, nut and bolt etc will be measured in separate item. Make: Havells/Crompton/Bajaj
Supply & fixing galvanised iron tube bracket of 40 mm dia light grade and 1.2 mtr length for fixing building security light, with all fixing arrangement including necesssary clamp, nut and bolt etc. as required size all as specified and as directed
Supply and fixing LED mid bay light fitting of 60 W with PDC housing suspended from ceiling/ wooden tress with and including suspending chain appx 2-3 Mtr,3 core copper flexible wire from ceiling rose to light fitting, nuts and bolts all as specified and directed. Make: Havells/Crompton/Bajaj
M&L for making of MS flat ring including welding, making hook, nuts and bolts for hanging ceiling fan all as specified and directed.
S&F , Wall mounted fan industrial type, single phase, 240 V, 450 mm sweep, 50 Hz, 1400 rpm, metal body with metal blades wall mounted fan, connected with 3 core 1.5 sq mm copper conductor cable from ceiling rose/socket to exhaust fan all as specified and as directed. Make: CG, Almonard, Havells, Bajaj, Standard.
Supply and lay on wall/in ground/on pole ISI marked XLPE insulated armoured, heavy duty, electric cable with aluminium conductors 1100 volts laid in trenches, floors, ducts, pipes drawn across the road/paths/drain/along poles/walls/floor/equivalent etc including jointing & testing complete all as specified of size 70 Sqmm , 3.5 core all as specified and directed.
Excavation in trenches not exceeding 1.5 mtr width and not exc 1.5 mtr in depth and getting out in hard /dense soil for laying / repairing of LT cable / GI pipe.
Supply, spread river sand of approval in cable trenches providing for cable cushioning as directed. NOTE :- Punned thickness of sand only will be measured and paid.
Removal of surplus soil to a distance not exc 50 mtrs away and depositing where directed at a level not exc 1.5 mtr above the starting point complete all as specified and directed by Engineer-in-Charge.
Returning , filling incl spreading levelling watering and well ramming in layers not exc 25 cm thick complete all as specified and directed by Engineer-in-Charge.
Supply and laying PCC cable covers for LT cable protection, Class LV, Type 1 of size 250x150x40mm complete all as specified and directed by Engineer-in-Charge.
Supply and fixing medium grade GI tubing of 50 mm dia for XLPE cable protection complete all as specified and as directed
S & F Vertical type MCCB TPN DB 4 way double door suitable for 125A MCCB made out of CRCA sheet housing with powder coating complete all as specified and directed.
Supply and replace MCCB 4P, 415V,16KA, 125 amps suitable for Vertical MCCB DB all as specified and directed .
Supply and replace MCB double door DB TPN 4 way with 200 Amps busbar all as specified and directed
Supply and replace MCB double door DB SPN 8 way with 200 Amps busbar all as specified and directed
Supply and fix in repair MCB TP 63 Amps 415 volts C series for fixing on MCB DB all as specified and directed.
Supply and fix in repair MCB TPN 63 Amps 415 volts C Series for fixing on MCB DB all as specified and directed.
Supply and fix in repair MCB TP 40 Amps 415 volts C Series for fixing on MCB DB all as specified and directed.
Supply and fix in repair MCB SPN 40 Amps 240 volts C Series for fixing on MCB DB all as specified and directed.
Supply and fix in repair MCB SP 6 to 40 Amps 240 volts C Series for fixing on MCB DB all as specified and directed.
Earthing complete with galvanised steel earth plate electrode 60cm x 60cm x 6mm thick burried directly in ground to a depth not less than 2.25 m below ground level with top edge of earth plate not less than 1.5 m below normal ground level connected to GI earth wire 4 mm dia drawn through and including GI protection pipe of light grade 15 mm bore by means of bolts, nuts, checknuts and washers all as shown in Electrical Plate No.3 of SSR Part-I and connected to main switch board including excavation and earth work, PCC chamber in 1:3:6, RCC Cover in 1:2:4 type B-1 reinforced with 8 mm dia MS bars at 10 cm c/c, 20 mm dia medium grade GI pipe with funnel and wire mesh complete and watering arrangement all as specified. (Note: GI pipe 15mm dia, GI wire 4mm dia upto 7.5m deemed to be included in quoted rate.)
SAI RUPA CONSTRUCTIONS
SURA INFRASTRUCTURE
M/s D.Krishna Varma
M/S DIVIJA BUILDERS
A SOMA RAJU
K LAKSHMAN SINGH AND CO
STANDARD AGENCIES
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .